
Installation Guide for GRANDSTREAM models including: GSC3506 V2 SIP Multicast Intercom Speaker, GSC3506 V2, SIP Multicast Intercom Speaker, Multicast Intercom Speaker, Intercom Speaker, Speaker
GSC3506 V2 - Quick Installation Guide - ation Center
Grandstream GSC3506 SIP Intercom Speaker - White - Corptel
File Info : application/pdf, 5 Pages, 3.60MB
DocumentDocumentGrandstream Networks, Inc.
126 Brookline Ave, 3rd Floor Boston, MA 02215. USA Tel : +1 (617) 566 - 9300 Fax: +1 (617) 249 - 1987 www.grandstream.com
please visit www.grandstream.com
GSC3506 V2
SIP/Multicast Intercom Speaker Quick Installation Guide
Content English................................................................................1
EN The GSC3506 V2 is not pre-configured to support or make
emergency calls to any type of hospital, law enforcement agency, medical care unit ("Emergency Service(s)") or any other kind of Emergency Service. You must make additional arrangements to access Emergency Services. It is your responsibility to purchase SIP-compliant Internet telephone service, properly configure the GSC3506 V2 to use that service, and periodically test your configuration to confirm that it works as you expect. It is also your responsibility to purchase traditional wireless or landline telephone services to access Emergency Services.
GRANDSTREAM DOES NOT PROVIDE CONNECTIONS TO EMERGENCY SERVICES VIA THE GSC3506 V2. NEITHER GRANDSTREAM NOR ITS OFFICES, EMPLOYEES OR AFFILIATES MAY BE HELD LIABLE FOR ANY CLAIM, DAMAGE, OR LOSS, AND YOU HEREBY WAIVE ANY AND ALL SUCH CLAIMS OR CAUSES OF ACTION ARISING FROM OR RELATING TO YOUR INABILITY TO USE THE GSC3506 V2 TO CONTACT EMERGENCY SERVICES, AND YOUR FAILURE TO MAKE ADDITIONAL ARRANGEMENTS TO ACCESS EMERGENCY SERVICES IN ACCORDANCE WITH THE IMMEDIATELY PRECEDING PARAGRAPH.
The GNU GPL license terms are incorporated into the device firmware and can be accessed via the Web user interface of the device at my_device_ip/gpl_license. It can also be accessed here: http://www.grandstream.com/legal/opensource-software To obtain a CD with GPL source code information please submit a written request to info@grandstream.com
~1~
OVERVIEW The GSC3506 V2 is a 1-way public address SIP speaker that allows offices, schools, hospitals, apartments and more to build powerful public address announcement solutions that expand security and communication. This robust SIP speaker offers crystal clear HD audio functionality with a high-fidelity 30-Watt HD speaker. The GSC3506 V2 support builtin whitelists ,blacklists and greylists to easily block unwanted calls, SIP and multicast paging, group paging and PTT. users can easily sculpt a state-of-the-art security and PA announcement solution. Thanks to its modern industrial design and rich features, the GSC3506 V2 is the ideal SIP speaker for any setting. PRECAUTIONS
· Do not attempt to open, disassemble, or modify the device.
· Do not expose this device to temperatures outside range of 0 °C to 45 °C in operation and -10 °C to 60 °C in storage.
· Do not expose the GSC3506 V2 to environments outside of the following humidity range: 10-90% RH (non-condensing).
· Do not power cycle your GSC3506 V2 during system boot up or firmware upgrade. You may corrupt firmware images and cause the unit to malfunction.
PACKAGE CONTENTS
Ceiling Mount Kit (optional and sold separately)
1x GSC3506 V2 Mounting Hole Cut-Out Template
1x Quick Installation Guide
1x Ceiling Bracket
8x Screws (M4)
~2~
GSC3506 V2 PORTS AND BUTTONS 7
8
6
5
1 2 NO. Port 1
2
3 4 5 6 7 8
Back panel
4
3
Label
Description
Front panel
(Mesh cover removed)
USB Port USB2.0, External USB Storage
Auxiliary Ports
2-pin Switch-in input port /2-pin Alarm-in input port /2-pin differential line out port /1-pin GND port
DC24Vport
One DC24V port
NET/PoE
Security Eyebolt
Ethernet RJ45 port (10/100Mbps) supporting PoE/PoE+/PoE++.
Security Eyebolt (Must Attach).
Ceiling hole
Reset
Ceiling hole position.
Factory reset button. Press for 10 seconds to reset factory default settings.
Volume Sound Volume buttons.
~3~
HARDWARE INSTALLATION
GSC3506 V2 can be mounted on the ceiling, boom or using ceiling bracket. Please refer to the following steps for the appropriate installation. Note: The recommended method of mounting is the ceiling mount, since it does not require any additional equipment for installation, use celiing bracket mounting only when the ceiling material is thin and cannot withstand the weight of GSC3506 V2.
Ceiling Mount
1
1. Drill a round hole with a diameter
of 230mm or use the Mounting Hole Cut-Out Template.
230mm
9in
or
Installation using Ceiling Bracket Kit (*sold separately)
406~605mm c16~23.8in
Then Fix the Ceiling Bracket using the screws from the kit as shown in the illustration (optional)
2. To ensure safety, install first the anti-fall ropes, then plug in the Ethernet and 2-pin Must attach
2
cables.
Note: The anti-fall rope diameter must be less than 5mm, and the pulling force must be greater than 25kgf.
3 3. Open the front cover with a flat-head screwdriver.
~4~
4. Align the device with the hole and push up
slowly with two hands.
4
Warning: Avoid pressing the horn with your hands.
4
3
5
5. Use a screwdriver and gently rotate
clockwise the screws marked as (1), (2),
1 2
(3) and (4) in the step 5 illustration.
Warning: If you use an electric drill, make sure to adjust it to the minimum speed gear first.
6. Align the notch on the front cover with the
notch on the device, press the whole front 6
cover to ensure that each buckle is fastened.
Boom Mount
1. Fix the Boom in the ceiling.
1/4 20UNC thread screw boom (not provided)
1
2. To ensure safety, install first the anti-fall ropes.
2
Note: The anti-fall rope diameter must be less than 5mm, and the pulling force must be greater than 25kgf.
3
4
3. Attach the Boom with GSC3506 V2 ceiling hole and rotate to fix it in place.
4. Plug in the Ethernet and 2-Pin 24V Power supply cable.
Note: When connecting to a PoE/PoE+/PoE++ switch, the 2-Pin 24V Power Supply cable connection becomes unnecessary.
~5~
POWERING AND CONNECTING GSC3506 V2
GSC3506 V2 can be powered on using PoE/PoE+/
PoE++ switch or connecting the 2-Pin 24V Power
Supply cable.
Using PoE Switch
Step 1: Plug a RJ45 Ethernet cable into the net-
work port of the GSC3506 V2.
Step 2: Plug the other end into the power over
Network Port
RJ45 Ethernet cable to Power over Ethernet (PoE)
Ethernet (PoE++) switch or PoE injector.
Switch or PoE injector.
Note: It is recommended to use PoE++ power supply to achieve the best audio effect.
Using 2-Pin 24V Power Supply cable
Step 1: Connect a 24V Power Supply.
Step 2: Connect the 24V Power Supply cable with
the 24V 2-pin Port (as shown in the illustration on
the right).
Note: To connect GSC3506 V2 to the local network,
24 V
RJ45 Ethernet cable needs to be connected too.
Power Supply
24V 2-pin Port
ACCESSING THE CONFIGURATION INTERFACE
A computer connected to the same network as the GSC3506 V2 can discover and access its configuration interface using its MAC address :
1. Locate the MAC address on the MAC tag of the unit, which is on the underside of the device, or on the package.
2. From a computer connected to same network as the GSC3506 V2, type in the following address using the GSC3506 V2's MAC address on your browser: http://gsc_<mac>.local
Example: if a GSC3506 V2 has the MAC address C0:74:AD:11:22:33, this unit can be accessed by typing http://gsc_c074ad112233.local on the browser.
For more information, please refer to GSC3506 V2 User Manual at: https://www.grandstream.com/support
~6~