Dwyer SERIES EDA | MERCOID® ELECTRONIC PRESSURE CONTROLLER

Features and Benefits

Applications

Description

The Series EDA Electronic Pressure Control is an extremely versatile compact package that can replace a separate gage, two switches, and a transmitter, saving money, installation time, and panel space. The EDA incorporates two SPDT relays with fully adjustable on and off points over the range for control or alarm use. The front face features LED indicators for switch status and a large, backlight, two-line display showing process value and indication units. Programming is easy with a simple menu structure, two-line display, and external programming buttons. The weatherproof housing is ideal for a wide variety of applications with panel mount, flush mount, or pipe mount ability.

Specifications

Specification Details
ServiceCompatible liquids and gases.
Wetted Materials316L SS.
HousingGlass filled plastic.
Accuracy±1% of FS including linearity, hysteresis, and repeatability (indicator and transmitter).
Stability< ±2% of FS per year.
Pressure Limits1.5 x range.
Temperature LimitsAmbient: 20 to 140°F (-6.6 to 60°C); Process: 0 to 176°F (-18 to 80°C).
Compensated Temperature Limits32 to 122°F (0 to 50°C).
Thermal Effect±0.05% of F.S./°F.
Display4-digit backlit LCD (Digits: 0.60" H x 0.33" W).
Power Requirements12-28 VDC/AC 50/60 Hz. (Can work at 8 VDC for 45 s). For T5 option: 14-30 VDC/AC 50/60 Hz. For -HV option: 120-240 VAC.
Power Consumption12-28 VDC/VAC: 2.5 watts; 120-240 VAC: 4.5 watts.
Electrical ConnectionsRemovable terminal blocks with 1/2" female NPT conduit connections.
Enclosure RatingMeets NEMA 4X (IP65).
Warm Up Time<10 s.
Mounting OrientationAny position.
Weight1.18 lb (535 g).
Agency ApprovalsCE, UL.

Switch Specifications

Specification Details
Switch Type2 SPDT relays.
Electrical Rating5 A @ 120/240 VAC, 1 A @ 30 VDC.
Repeatability±1% of FS (switching only).
Set PointsAdjustable 0-100% of FS.
Switch IndicationExternal LED for each relay on the front panel.
Switch ResetManual or automatic.

Transmitter Specifications

Specification Details
Output Signal4-20 mA, 1-6 VDC, 1-5 VDC, or 0-10 VDC (direct or reverse output selection).
Minimum Excitation14 VDC.
Zero and Span AdjustmentsMenu scalable within the range.

Dimensions

The dimensions diagram shows a circular pressure controller with a front panel diameter of approximately 5 inches (127.00 mm). The cutout diameter for panel mounting is approximately 4-17/32 inches (115.09 mm). The unit features a 1/4 male NPT process connection with a 3/4 inch hex wrenching area, measuring 27/32 inches (21.43 mm) from the front. It also includes a 1/2 female NPT conduit entry. Overall depth dimensions are provided, with key measurements like 3-1/16 inches (77.89 mm) and 3-15/32 inches (88.11 mm) for different mounting configurations.

Wiring Diagram

The wiring diagram illustrates the electrical connections for the Series EDA Electronic Pressure Controller. It shows two SPDT relays, labeled SP1 and SP2, each with Common (COM), Normally Open (NO), and Normally Closed (NC) terminals, connected via CONN7 and CONN8 respectively. A Line Input is provided via CONN9, and a Receiver Output (4-20 mA or Voltage) is available at CONN10. The diagram also details connections for two loads: LOAD 1 can handle 5A at 250 VAC for 120/240 VAC power, or 1A at 32 VDC for 30 VDC power. LOAD 2 is for 12-30 VDC/AC power, rated at 375 mA at 250 VAC.

How to Order

Construct a product code using the bold characters from the chart below:

SERIES EDA: Electronic pressure controller
HOUSING W: Weatherproof
PROCESS CONNECTION -N1: 1/4" male NPT
CONDUIT CONNECTION E1: Two 1/2" NPT
OPTIONS -AT: Aluminum adhesive tag
-HV: 120-240 VAC power
-NIST: NIST certificate
-P: 1/2 NPSM conduit plug
TRANSMITTER OUTPUT T0: None
T1: 4-20 mA
T2: 1-5 VDC
T3: 0-5 VDC
T4: 1-6 VDC
T5: 0-10 VDC
RANGE -02: 0-20 psig
-03: 0-60 psig
-04: 0-100 psig
-05: 0-150 psig
-06: 0-300 psig
-07: 0-600 psig
-08: 0-1000 psig
-09: 0-1500 psig
-10: 0-3000 psig

Example code: EDA-W-N1-E1-02-T3-NIST

Accessories

Model Description
A-5901/2" conduit plug, watertight
A-EDA-BRKFlush mount bracket for EDA, bracket is then surface mounted, steel with gray hammertone epoxy finish

Order Online Today!

Visit: dwyer-inst.com/Product/SeriesEDA

Connect with us: [Facebook] [LinkedIn] [YouTube] [Instagram]

Models: EDA Serise MERCOID Electronic Pressure Controller, EDA Serise, MERCOID Electronic Pressure Controller, MERCOID, Electronic Pressure Controller, Pressure Controller, Controller, Electronic Controller

File Info : application/pdf, 4 Pages, 4.84MB

DS EDA ? hstc=48098232.c4a577029c49e44b73bd3bee6fa38565.1599523200141.1599523200142.1599523200143.1& hssc=48098232.1.159952

References

Adobe InDesign 17.0 (Macintosh) Adobe PDF Library 16.0.3

Related Documents

Preview Dwyer Series MSX Magnesense® Differential Pressure Transmitter: Specifications and Installation Guide
Comprehensive guide to the Dwyer Series MSX Magnesense® Differential Pressure Transmitter, covering specifications, installation, operation, and configuration for building control applications. Learn about its features, output options, and setup.
Preview Dwyer Series MS Magnesense® Differential Pressure Transmitter
Overview of the Dwyer Series MS Magnesense® Differential Pressure Transmitter, monitoring pressure and air velocity with features like field-selectable ranges, upgradeable LCD, and adjustable damping. Includes specifications, model chart, and accessories.
Preview Dwyer Digihelic® Differential Pressure Controller Series DH - Gage, Switch, Transmitter
The Dwyer Digihelic® Series DH is a 3-in-1 differential pressure controller offering gage, switch, and transmitter functions. It features 0.5% accuracy, flexible power options, Modbus® communication, and is ideal for air flow, duct pressure, and clean room applications.
Preview Dwyer Series 605 Magnehelic Differential Pressure Indicating Transmitter Specifications
Detailed technical specifications, product overview, and model information for the Dwyer Series 605 Magnehelic Differential Pressure Indicating Transmitter, suitable for HVAC and low differential pressure monitoring applications with a 4-20 mA output signal.
Preview Dwyer Series 616KX Differential Pressure Transmitter User's Guide
User's guide for the Dwyer Series 616KX Differential Pressure Transmitter, detailing installation, specifications, electrical connections, operation, zero adjustment, output signal configuration, precautions, maintenance, and warranty information.
Preview Dwyer Series MSX Magnesense® Differential Pressure Transmitter Datasheet
Detailed specifications, applications, and ordering information for the Dwyer Series MSX Magnesense® Differential Pressure Transmitter, featuring configurable ranges and versatile output signals for building control and industrial applications.
Preview Dwyer 605 Series Magnehelic® Indicating Differential Pressure Transmitter
Product overview of the Dwyer 605 Series Magnehelic® Indicating Differential Pressure Transmitter, detailing its features, specifications, applications, and model options for monitoring differential pressure in HVAC and industrial systems.
Preview Dwyer Series DM DigiMag Differential Pressure Transmitter Quick Start Guide
Quick start guide for the Dwyer Series DM DigiMag Differential Pressure Transmitter, providing essential information for mounting, wiring, and calibration.