Installation Guide for SELTZA models including: SeltzaHub SeltzaTap Compact Faucet, SeltzaTap Compact Faucet, Compact Faucet, Faucet
Seltza – SeltzaTap
QR code directory for SeltzaTap's online presence.
File Info : application/pdf, 20 Pages, 3.82MB
DocumentDocumentInstallation, Operation, and Maintenance Guide SeltzaHub/ SeltzaTap/ SeltzaTap Compact Revised 27.11.2024 Table of contents SeltzaHub What's included Technical Specifications SeltzaTap Technical Specifications SeltzaTap Compact Technical Specifications SeltzaHub Installation overview Installation preparation SeltzaTap Installation SeltzaHub Installation Operation SeltzaTap Operation SeltzaTap Compact Operation SeltzaTap Maintenance SeltzaHub Troubleshooting Warranty 3 4 5 6 7 8 9 11 14 15 16 17 19 20 2 Installation, Operation, and Maintenance Guide What's included? SELTZAHUB SeltzaHub Seltza regulator TR21-4 threads Regulator adapter for CGA-320 threads T-Stop valve 2@ 3ft x 1/4' for Water inlet and C02 3 @ Valve kit Power Cord 3 Installation, Operation, and Maintenance Guide Technical Specifications SELTZAHUB Chilled water Seltza Ambient water water 400mm 15 3/4" C02 inlet Water inlet C02 Pressure relief valve 230mm 9 1/4" 360mm 14 1/4" 430mm 17" (with clearance for valves) Voltage Current Cooling capacity Refrigerant Type and Charge Cooling temperature CO2 inlet pressure Water inlet pressure SeltzaHub only weight SeltzaHub weight with packaging 120V 60Hz 4A 6 litre/ hour R600a 3-12°C 65-75 psi 20 60 psi 13.0kg (28.7 lbs) 14.9kg (32.1 lbs) 4 Installation, Operation, and Maintenance Guide Technical Specifications 255mm SELTZATAP 90 cm hoses with 3/8" compression fitting 508mm SeltzaTap 50mm 175mm 216mm Note: Handle rotates 45º towards backsplash. Allow 50mm (2") additional clearance. 90cm 5/16" tubing Countertop hole and thickness requirements 90 cm long 5/16 inch of PE tubing Blue tubing = Chilled Seltza (Sparkling) White Tubing = Chilled Still Clear Tubing = Ambient Still 35mm Faucet hole diameter in Countertop is 1 3/8" (35mm) Max Countertop thickness is 1 3/4" (45mm) 5 Installation, Operation, and Maintenance Guide SeltzaTap Compact Identical installation as SeltzaTap. SELTZATAP COMPACT To change Aerator 324mm 350mm Washer Aerator Spout (unscrew) 90 cm hoses with 3/8" compression fitting 50mm 172mm SeltzaTap 202mm Note: Handle rotates 45º towards backsplash. Allow 50mm (2") additional clearance. Countertop hole and thickness requirements 90cm 5/16" tubing 35mm Faucet hole diameter in Countertop is 1 3/8" (35mm) Max Countertop thickness is 1 3/4" (45mm) 90 cm long 5/16 inch of PE tubing Blue tubing = Chilled Seltza (Sparkling) White Tubing = Chilled Still Clear Tubing = Ambient Still 6 Installation, Operation, and Maintenance Guide Installation Overall view of installation SELTZAHUB Regulator SeltzaTap CO2 cylinder (not included) Seltza water Cold water Ambient water 1/4" T-stop valve (existing valves) Filter (optional) 7 Installation, Operation, and Maintenance Guide Installation Preparation Factory Testing Each SeltzaHub and Seltza Tap is factory tested prior to packaging. For this reason, you may notice dampress / wetness when installing. How To Use Quick Connect Fittings 1 Cut the tube square and push into the tube stop. For metal tube, remove burrs and chamfer tube end to prevent O-ring seal from being damaged. 2 Fitting grips before it seals. Ensure tube is pushed into the tube stop. 3 Tube is secured in position 4 DISCONNECTION PROCEDURE Push collet against body and slide tube out fitting. 24 Hours Before Start-up Ensure the SetzaHub us put into the installation location 24 hours before start-up. This ensures there will be no issues with the refrigerant system. 8 Installation, Operation, and Maintenance Guide Installation of Seltza Tap Turn off hot and cold 1 water from existing valves under the sink. Disconnect existing hot 2 and cold water lines from existing valves. SELTZATAP 3 Remove faucet nut from existing faucet. May have two screws or just be a nut. 4 Install SeltzaTap faucet in countertop. 1 2 Make sure faucet is aligned with sink. 6 5 Tighten screw faucet nut till finger tight. Tighten the two screws on the faucet nut 7 to ensure faucet is tight. 9 Installation, Operation, and Maintenance Guide Installation of Seltza Tap SELTZATAP 8 Install T-Stop Valve in existing cold water line. May require an adapter. 9 Connect cold water faucet to the T-Stop valve. May require an adapter. 10 Connect hot water faucet hose to the hot water piping. May require an adapter Sample image under the sink T-stop valve 11 Connect the chilled sparkling, chilled still, and ambient still 5/16" tubing from SeltzaHub to SeltzaTap. 5/16' existing valves Ambient water (Clear) Seltza water (Blue) Chilled water (White) 10 Installation, Operation, and Maintenance Guide SELTZAHUB Installation of Seltza Hub Note:Disregard the steps already completed from Seltza Tap instalation. Turn off cold 1 water from existing valve under the sink. Disconnect existing 2 cold water lines from existing valve. 3 Install T-Stop Valve in existing cold water line. 4 Connect cold water faucet hose to the T-Stop valve. Sample image under the sink T-stop valve 5 Install Valve Kits into the Hub ports for Chilled, Seltza and Ambient. Existing valves Check for leaks. Ensure T-Stop Valve is turned off. Turn on Main Cold Water supply and check for any leaks. (Show picture of T-Stop valve off and Main water on) 11 Installation, Operation, and Maintenance Guide Installation of Seltza Hub SELTZAHUB 6 Disassemble the blue safety clips and take out the plugs. (if applicable). 7 Connect the 1/4" diameter water pipe to the T-stop valve or the filter system and the SeltzaHub water inlet. Water inlet C02 inlet T-stop valve 8 Connect the chilled sparkling, chilled still, and ambient still 5/16" tubing from SeltzaHub to SeltzaTap. For third party faucets modify connections to work with the SeltzaHub 1/4" (Optional) Filter 9 4) Check for water leaks in the system. a) Ensure all the valves on the side of the machine are off. Ambient water (Clear) Seltza water (Blue) Chilled water (White) 5/16' b) Turn on Main water valve. Check for leaks c) Turn on T-Stop valve Check for leaks d) Turn on Each valve on the side of SeltzaHub and wait for 5 seconds. Check each valve for leaks. e) Leave valves open 12 Installation, Operation, and Maintenance Guide Installation 10 Take the gas tubing, cut as needed and assemble the tubing to the pressure reducer. to Seltza regulator 11 Connect 5/16" tube in the back of the SeltzaHub to CO2 inlet. SELTZAHUB 12 Assemble the pressure reducer to the CO2 cylinder. Ensure regulator is off. Turn counter-clockwise till it stops. 420gram CO2 Any CO2 bottles should always be upright during use, storage and transit. If the bottle has been left horizontal, place upright and let it stand for 60+ minutes to allow content to settle before initialising. Regulator adapter CGA-320 13 TURN ON WATER TO FILL THE TANK mins. ON SELTZAHUB Check for any leaks. Allow 5 minutes for tank to fill 14 PLUG IN AND TURN ON THE SELTZA HUB Allow 20 minutes to cool down 5, 10, or 20lbs CO2 mins. 15 Pull Seltza Hub C02 Pressure Relief valve until there is no sound of Gas scaping. 16 TURN CO2 REGULATOR TO 65 PSI Never turn on CO2 before the tank is filled with water. 17 OPEN FAUCET SPARKLING WATER VALVE AND LET 1.0L (32OZ) OF WATER COME OUT 1.0L/ (32oz) Water coming out of second nozzle. Left hand lever 18 REPEAT STEP 17 AFTER 24 HOURS Feel free to enjoy your sparkling water during this 24Hours period. HOURS 1.0L/ (32oz) Water coming out of second nozzle. Left hand lever 19 ENJOY YOUR SELTZA WATER. Note carbonation will continue to increase over the next 72 hours. 13 Installation, Operation, and Maintenance Guide Operation 1 SELTZAHUB Button functions No Name and function Comments 1 Display Show temperature of the cooling Error: Fault of the machine 2 2 Temperature adjustments 3 3 Power Button Back side of the machine 6 No Name and function 5 4 ON - OFF Comments 5 CO2 inlet CO2 gas to be 65-75 Psi 6 Water inlet 4 Water pressure to be 20-65 Psi Reminder: Vacation and Longer Absences from the Home Treat your SeltzaHub as you would other water-connected appliances in your home. Prior to Leaving: (1) Turn off CO2 regulator and pull its pressure relief (2) Power-off the Hub (3) Turn off water undersink (4) Option to drain the water from tank by running the left-hand faucet handle Upon Return: Follow start-up instructions (See steps 13 to 19 of SeltzaHub Installation) 14 Installation, Operation, and Maintenance Guide SeltzaTap Operation Water coming out of second nozzle. Left hand lever Chilled Seltza water Chilled Still water Ambient Still water (will be the temperature of the main building supply water) SELTZATAP Right hand lever Hot and cold water for cleaning and dishes. Spray function Hose is removable 15 Installation, Operation, and Maintenance Guide SeltzaTap Compact Operation SELTZATAP COMPACT Left hand lever Chilled Seltza water Chilled Still water Ambient Still water (will be the temperature of the main building supply water) Right hand lever Hot and cold water for cleaning and dishes. 16 Installation, Operation, and Maintenance Guide SELTZATAP SeltzaTap Maintenance Care Instructions · Never use cleaning materials or appliances with an abrasive effect, such as unsuitable cleaning powders, scouring pads, steel wool, etc.. · When using spray cleaners, spray the cleaning solution onto a soft cloth or sponge, never directly onto the SeltzaTap. · After cleaning, rinse thoroughly with clean water to remove any cleaner residue. Changing Cartridges Sparkling water (Left Hand Cartridge) "If the sparkling water has a continual drip that does not go away when readjusting the handle into the off position, it is time replace the cartridge." 1. Turn water to the faucet off at the SeltzaHub valves. 2. Loosen set screw on bottom of handle: · Pull out cap · Set screw is a 2.5mm hexscrew 3. Remove the nut with an adjustable wrench. 4. Pull out the old cartridge 5. Install the new cartridge, ensuring the tabs lineup as per the picture below. 6. Replace the handle, reinserting the set screw and cap. 7. Turn the water to the faucet back on at the SeltzaHub valves Handle Nut 2.5mm hex screw Cartridge Faucet body Faucet body Ensure tabs lineup Cartridge 17 Installation, Operation, and Maintenance Guide SELTZATAP SeltzaTap Maintenance Changing Cartridges Regular water (Right Hand Cartridge) 1. Turn the water off to the faucet at the Hot and Cold valves below sink. (As shown.) 2. Loosen set screw 1 below. (Set screw is a 2.5mm hex screw) 3. Remove 2 below by screwing out with hand 4. Remove the nut with an adjustable wrench ( 3 ). 5. Pull out old cartridge 4 . 6. Install new cartridge ensuring the tabs lineup. Turn off hot and cold water from existing valves under the sink. 4 3 2 1 Faucet body Ensure tabs lineup Cartridge 18 Installation, Operation, and Maintenance Guide SELTZAHUB Troubleshooting No Fault When using the Seltza 1 water, gas comes out of the Seltza Tap. Actions to be taken Wait 10-20 mins, then re-pour. 2 Machine is not working properly Recommended to shutdown the machine and re-operate it after 1 minute. 3 SeltzaHub display error E1 Pump working more than 5 minutes E2 Cold water running more than 5 minutes E3 No water inlet more than 10 minutes 4 Seltza not working or flat CO2 bottle is empty. Power is off. Not enough bar pressure. 5 Noise If there are any unusual NOISE, shutdown the SeltzaHub, close the water inlet and gas inlets. Comments This happens when taking to much Seltza water at one time. Turn-off and re-start after 1 minute Turn-off and re-start after 1 minute Turn-off and re-start after 1 minute Replace CO2 bottle. Turn on the power switch. Slightly increase CO2 bar pressure. Max 75psi Do not try to fix the machine. Contact Seltza customer support. This marking indicates that this product should Correct Disposal of this product: not be disposed with other household wastes. 6 To prevent possible harm to the environment or human health from uncontrolled waste disposal, Appliance recycling recycle it responsibly to promote the sustainable reuse of material resources. Contact hello@seltzatap.com for additional support. 19 Installation, Operation, and Maintenance Guide SELTZAHUB WARRANTY Any claim under this warranty must be made within 1 year of the date of receipt of the product. This product is warranted to be free of defect of material and workmanship for 1 year from date of receipt. To make claim under warranty, take the product and proof of purchase and email hello@seltzatap.com The warranty only applies if the product was used and/ or installed in accordance with the user guide and/or installation instructions. This warranty is given in lieu of all other express or implied warranties and manufacturer shall in no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law. Applicable to all above, is that the warranties need to be approved by Seltza to ensure product was not incorrectly used, installed or claimed. False and incorrect claims will be pursued at Seltza discretion, including chargeable inspection and labour costs incurred. 20 Installation, Operation, and Maintenance GuideAdobe PDF library 16.07