Instruction Manual for RAB models including: FR2X2, FR1X4, FR2X4, FR2X2 Frame Light, FR2X2, Frame Light, Light
RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
FRAME Light - RAB Lighting
File Info : application/pdf, 3 Pages, 403.28KB
DocumentDocumentINSTRUCTIONS FRAME LIGHT FIELD-ADJUSTABLE INSTALLATION RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com FR2X2 FR1X4 FR2X4 IMPORTANT READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside. · Suitable for operation in ambient not exceeding 45° C. · Caution Risk of Fire. · Access above ceiling is required. · Min 90° Supply Conductor. · Suitable for Damp Locations. RECESSED CEILING MOUNTING The fixture is suitable only for indoor recessed ceiling application. 1. Remove Ceiling Tile and place the Frame Light into Ceiling Grid (Fig. 1). Clip the LED Driver Assembly onto the T-BAR and attach the connector to the Frame Light (Fig. 2). 2. Attach the Tether Cable onto Grid Support Wire or other suitable structure (Fig. 3). 3. Remove the LED Driver Box Cover and connect power. Use appropriate UL rated wire connectors as required by code to make electrical splices to fixture leads. Follow appropriate mounting and wiring instructions as per code (Fig. 5). WARNING: To prevent wiring damage or abrasion do not expose wiring to edges of sheet metal or other sharp objects. 4. Secure the Driver Box Cover. 5. Set desired Field-Adjustable settings for Color Temperature (CCT) and/or Power (W), see Field-Adjustment section (Fig. 4). 6. Place the Ceiling Tile onto the Frame Light. Fig: 2 Ceiling Tile Grid Fig: 3 LED Driver Assembly Frame Light Tether Cable Fig: 1 Ceiling Tile LED Driver Assembly Frame Light End-view of Driver Assembly INSTRUCTIONS FRAME LIGHT FIELD-ADJUSTABLE INSTALLATION RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com FIELD ADJUSTMENT Follow instructions below to change Fixture Color Temperature (CCT) and/or Power (W) from factory settings listed below. Color Temperature (CCT) Selection: This product is equipped with 3000K, 3500K, 4000K, 5000K, 6500K (CCT) Color Temperature selection. For maximum light output use the 4000K Color Temperature. Power (Wattage) Selection: This product is equipped with power output selection. FR1X4 40/35/30/25/20W FR2X2 40/35/30/25/20W FR2X4 50/45/40/35/30W Factory Settings: 1X4 - 40W / 4000K 2X2 - 40W / 4000K 2X4 - 50W / 4000K 1. Locate the Selection Switches on the side of LED Driver Assembly as shown in Fig. 4. 2. Select Color Temperature (CCT) and/or Power (W) by sliding the respective Switch to the desired setting. 0-10V DIMMABLE WIRING Universal voltage driver permits operation at 120V through 277V, 50 or 60 Hz. For 0-10V dimming, follow the wiring directions as shown in Fig. 5. 1. Connect the black fixture lead to the LINE supply lead. 2. Connect the white fixture lead to the COMMON supply lead. 3. Connect the GROUND wire from fixture to supply ground. 4. Connect the purple fixture lead to the (V+) DIM lead. 5. Connect the gray fixture lead to the (V-) DIM lead. 6. Cap the yellow fixture lead, if present. Fig: 5 LINE COMMON ( + ) DIM V ( - ) DIM V GROUND BLACK WHITE PURPLE PINK Vaux 12V YELLOW GREEN LIGHT FIXTURE Fig: 4 CLEANING Field-Adjustable Switches CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized. 1. Clean lens & fixture with non-abrasive cleaning solution. 2. Do not open fixture to clean the LEDs. Do not touch the LEDs. Power (W) Switch Color Temperature (CCT) Switch TROUBLESHOOTING 1. Check the line voltage at fixture. Refer to wiring directions. 2. Is the fixture grounded properly? 3. Blinking light of this thermally protected luminare may indicate overheating. Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. INSTRUCTIONS FRAME LIGHT FIELD-ADJUSTABLE INSTALLATION RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install and end users to save energy. We'd love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com BATTERY BACKUP MODELS WIRING NOTE: Make sure that the necessary branch circuit wiring is available. An UNSWITCHED AC source of power is required. The emergency driver must be fed from the same branch circuit as the LED driver. CAUTION: Do not use any supply voltage other than 120-277V 50/60 HZ (Fig. 6). Battery Test Button is provided with adhesive backing. Align the Test Button to edge of Fixture Frame closest to the lens for easy accessibility as shown in Fig.7. 1. Connect UNSWITCHED HOT fixture lead to HOT AC supply line. 2. If using an UNSWITCHED circuit, connect UNSWITCHED and SWITCHED lines together. 3. If using a SWITCHED circuit, connect SWITCHED HOT AC fixture lead to the external. 4. For 0-10V Dimming connect DIM (+) purple and DIM (-) pink leads to 0-10V dimming connection. 5. All unused leads must be capped and insulated. 6. IMPORTANT: After installation is complete supply AC power and then connect the BATTERY. 7. When Unswitched and Switched power are ON the Fixture should be on and the Charging Indicator Light will illuminate. 8. Once the BATTERY has charged for at least one hour a short duration test may be performed by pressing the Test Button (Fig. 7). 9. After the battery has charged for 24 hours a long duration test can be performed by shutting power to the fixture. OPERATION 1. When AC power is applied, the charging indicator light is illuminated, indicating that the BATTERY is being charged. 2. When power fails, the standby power automatically switches to emergency power (internal battery), operating at reduced illumination. The emergency driver supplies standby power for a minimum of 90 minutes. 3. When AC power is restored, the emergency driver automatically returns to charging mode. MAINTENANCE Although no routine maintenance is required to keep the emergency driver functional, it should be checked periodically to ensure that it is working. The following schedule is recommended: 1. Visually inspect the charging indicator light monthly. It should be illuminated. 2. Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds. 3. Conduct a 90-minute discharge test once a year. Fixture would operate at reduced illumination for a minimum of 90 minutes. TROUBLESHOOTING 1. Is the fixture grounded properly? 2. If the charging indicator light does not illuminate after pressing the Test Button (Fig. 7), check if battery is connected properly. Fig: 6 Fig: 7 LIGHT FIXTURE Purple/DIM+ Pink/DIM Blue/Switched Line Black/Unswitched Line White/Neutral Green/Ground INSIDE FIXTURE BACKUP DRIVER BATTERY CONNECTOR: CONNECT ONLY AFTER AC SUPPLY POWER IS CONNECTED BATTERY Test Button Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance. © 2025 RAB LIGHTING Inc. FRAME LIGHT - 0425 P-101790 Easy Answers rablighting.com Visit our website for product info Tech Help Line Call our experts: 888 722-1000 e-mail Answered promptly - tech@rablighting.com RAB WARRANTY: RAB'S Warranty is subject to all terms and conditions found at rablighting.com/warranty. Free Lighting Layouts Answered online or by request