1. Kupu Whakataki
This manual provides essential instructions for the safe and effective installation, operation, and maintenance of the Okin JLDQ-12 and JLDQ.12.133.226M power recliner and bed motor actuator replacement. Please read this manual thoroughly before installation and use to ensure proper function and longevity of the product.
2. Hua Neke Atuview me nga Waehanga
The Okin JLDQ.12.133.226M is an electric linear actuator designed for power recliners and adjustable beds. It is specifically engineered as a direct replacement for the original Okin JLDQ.12.133.226M model.
2.1 Waenga Matua
- Actuator Motor: The main unit responsible for linear movement.
- Tūhono:
- 5-pin round plug: For connecting to the switch hand control.
- 2-pin square plug: Mo te hono ki te hiko hiko.

Figure 1: Okin JLDQ.12.133.226M motor actuator with attached cables.

Whakaatu 2: Taipitopito view of the 5-pin round plug for the recliner switch and the 2-pin square plug for the power supply.
3. Whakatakotoranga
| Āhuahira | Taipitopito |
|---|---|
| Ingoa Tauira | JLDQ.12.133.226M |
| Raukaha Uta | Push force: 750N, Pull force: 750N |
| Te whiu | 226 mm |
| Minimum Installation Size (Shrink) | 133 mm |
| Maximum Installation Size | 359 mm |
| Auautanga Mahi | Whakakā 1 meneti / Whakaweto 8 meneti |
| Tere | 29VDC SMPS, 10 sec without load |
| Te ahua | Pango (PA), Hiriwa Mā (Konumohe) |
| Hunga Hua | 8.9 x 8.9 x 14.13 inihi |
| Taumaha Tūemi | 4.59 pauna (2.09 Kirokaramu) |

Figure 3: Product label displaying technical data and model information, including serial number Q21061699 00271 me te tauira JLDQ.12.133.226M. For patent information, visit www.dewertokin.de/patents.
4. Tatūnga me te Tāuta
Tuhipoka Hototahi Nui: This motor is specifically designed to replace the OKIN model JLDQ.12.133.226M. Different actuator/motors are generally not compatible due to strict requirements for minimum installation dimensions, stroke, and plug types. Always verify your existing motor's brand and model before attempting replacement.
4.1 Nga Tirohanga i mua i te whakaurunga
- Verify Model: Confirm that your existing motor is an Okin JLDQ.12.133.226M.
- Momotu Hiko: Ensure the power supply to the recliner or bed is completely disconnected before starting any installation work.
- Tirotiro Wae: Check the new motor and cables for any visible damage.
4.2 Nga Waahi Whakataunga
- Tango Motiika Tawhito: Carefully detach the old motor from the recliner or bed frame. Note how it was connected to ensure correct installation of the new unit.
- Position New Motor: Align the new Okin JLDQ.12.133.226M motor with the mounting points on the frame.
- Secure Motor: Fasten the motor securely to the frame using appropriate hardware (not included, typically reused from the old motor or provided with the furniture).
- Tūhono Taura:
- Honoa te 5-pin a tawhio mono to the hand control switch.
- Honoa te 2-pin square plug ki te taputapu hiko.
- Whakaha Uepu: Ensure all cables are routed safely, away from moving parts, and secured to prevent pinching or damage.

Whakaahua 4: Example of the motor actuator mounted, showing its extended position.
5. Nga Tohutohu Whakahaere
Once the motor is correctly installed and all connections are secure, reconnect the main power supply to your recliner or adjustable bed.
- Whakahiko: Plug the recliner/bed into a suitable power outlet.
- Mana Ringa: Use the hand control unit to operate the recliner or bed. Press and hold the appropriate buttons to extend or retract the actuator, adjusting the position as desired.
- Huringa Mahi: Adhere to the specified operation frequency: On 1 minute / Off 8 minutes. Continuous operation beyond 1 minute can lead to overheating and damage to the motor. Allow the motor to cool down for at least 8 minutes after 1 minute of continuous use.
6. Tiaki
Regular maintenance ensures the longevity and reliable operation of your Okin motor actuator.
- Te horoi: Wipe clean the exterior of the motor and cables with a dry or slightly damp kakahu. Kaua e whakamahi i nga kai horoi awhiowhio me te rukuhia te waeine ki te wai.
- Tirohanga taura: Periodically check all cables and connections for wear, fraying, or loose plugs. Ensure they are securely attached and not pinched.
- Nga Waahanga Nuku: Ensure the linear shaft moves freely and is not obstructed by debris or fabric.
- Whakahinuhinu: The motor is generally maintenance-free regarding internal lubrication. Do not attempt to lubricate internal components unless specifically instructed by Okin support.
7. Te Raru
If your recliner or adjustable bed is not functioning correctly, follow these troubleshooting steps:
- Karekau he nekehanga:
- Check if the power cord is securely plugged into the wall outlet and the power supply unit.
- Verify that the 2-pin square plug from the motor is firmly connected to the power supply.
- Ensure the 5-pin round plug from the motor is properly connected to the hand control.
- Whakamatautauria te putanga o te pakitara me tetahi atu taputapu kia mohio kei te whai mana.
- Intermittent Movement:
- Inspect all cable connections for looseness or damage.
- Ensure the motor is not overheating. Allow it to cool down if it has been operated continuously.
- Haruru rerekee:
- Check for any obstructions around the motor or the linear shaft.
- Ensure the motor is securely mounted and not vibrating against the frame.
- Motor Does Not Extend/Retract Fully:
- Verify that there are no physical obstructions preventing full movement.
- Ensure the motor is correctly installed with the specified minimum and maximum installation sizes.
If issues persist after following these steps, contact Okin customer support or a qualified technician.
8. Nga Korero Haumaru Nui
- Me momotu te hiko i mua i te tāutanga, te tiaki, te horoi rānei.
- I hangaia tenei hua mo te whakamahi o roto anake.
- Do not allow children or pets to play near the moving parts of the recliner or bed.
- Ensure proper cable routing to prevent tripping hazards or damage to the cables.
- Do not attempt to modify the motor or its components. Unauthorized modifications can lead to malfunction and void the warranty.
- Only use this motor as a replacement for the specified Okin JLDQ.12.133.226M model. Using incompatible parts can cause damage to the furniture and the motor.
9. Pūtāhui me te Tautoko
For warranty information, technical support, or further assistance, please refer to the official Okin website or contact your product retailer. Keep your purchase receipt as proof of purchase for warranty claims.
You can visit the Okin store for more products and information: Toa Okin i runga i a Amazon.