Elkay 400A

ELKAY 400A Columbus Pneumatic Timer Instruction Manual

Tauira: 400A

Kupu Whakataki

This manual provides detailed instructions for the installation, operation, and maintenance of your ELKAY 400A Columbus Pneumatic Timer. This device is designed to automatically switch off lighting after a user-defined period, offering a practical solution for energy management.

Nga Korero Haumaru Nui

WARNING: Risk of electric shock. Installation should only be performed by a qualified electrician or competent person in accordance with national wiring regulations.

  • Always disconnect power at the main circuit breaker before installing or servicing the timer.
  • Ensure all wiring connections are secure and correctly insulated.
  • Kaua e neke atu i te whakatauranga kawenga mōrahi kua tohua mō tēnei pūrere.
  • I hangaia tenei hua mo te whakamahi o roto anake.
  • Kaua e taea e nga tamariki.

Ka mutu te huaview

The ELKAY 400A Columbus Pneumatic Timer is a single-contact, push-button operated timer. It is designed to replace standard single-gang wall switches and does not require a neutral connection. The timer provides an adjustable delay period, automatically turning off connected lighting after the set time has elapsed.

ELKAY 400A Columbus Pneumatic Timer, front view

Whakaahua 1: Mua view of the ELKAY 400A Columbus Pneumatic Timer. Shows the white ABS casing and the central push-button mechanism.

Āhuatanga matua:

  • Katia Aunoa: Turns off lighting after a set time.
  • Taihoa Wha Whakatika: Configurable from approximately 5 seconds to 5 minutes.
  • Tāutatanga ngawari: Replaces existing single-gang wall switches.
  • No Neutral Required: Simplifies wiring.
  • Hototahi: Suitable for fluorescent (up to 6 fittings) and incandescent lighting.
  • Hanga Roa: Made from Acrylonitrile Butadiene Styrene (ABS).

Tohutohu Tāuta

  1. Momotu Hiko: Before beginning installation, ensure the electrical supply to the circuit is completely disconnected at the consumer unit/fuse box. Verify with a suitable voltage Kaiwhakamatautau.
  2. Tango Whakawhiti Tīariari: Carefully remove the existing wall switch from its mounting box. Note the wiring connections.
  3. Waea waea:
    • Connect the incoming live wire to the terminal marked 'L' or 'IN' on the ELKAY 400A timer.
    • Connect the switched live wire (going to the light fitting) to the terminal marked 'SW' or 'OUT' on the ELKAY 400A timer.
    • Note: This timer does not require a neutral connection.
  4. Te Whakarerekētanga o te Whakaroa Wā:

    The time delay is adjusted via a small screw located on the rear of the timer mechanism. Use a small screwdriver to turn this screw. Turning clockwise typically increases the time, and counter-clockwise decreases it. The timing range is approximately 5 seconds to 5 minutes. Adjust this setting before fully mounting the timer.

    Note: Timings are approximate and may require fine-tuning after initial power-up.

  5. Whakapiki: Carefully place the wired timer into the wall mounting box, ensuring no wires are pinched. Secure the timer to the box using the provided screws. Attach the faceplate.
  6. Hononga Hiko: Restore power to the circuit at the consumer unit/fuse box.
  7. Whakamātautau: Press the timer button to activate. Observe the connected lighting and verify that it switches off after the set delay. Adjust the time delay screw further if necessary (repeat steps 1, 4, 6, 7).

For optimal performance, ensure the mounting surface is flat and does not exert undue pressure on the timer mechanism, which could affect timing accuracy.

Nga Tohutohu Whakahaere

To operate the ELKAY 400A Columbus Pneumatic Timer, simply press the central button. This action will switch on the connected lighting and simultaneously activate the internal pneumatic delay mechanism. The lighting will remain on for the pre-set duration (between 5 seconds and 5 minutes) and then automatically switch off.

  • A single press activates the timer.
  • The timer cannot be manually turned off before the delay period expires.
  • Pressing the button again during an active cycle will restart the timer, extending the light-on period.

Te tiaki

The ELKAY 400A Pneumatic Timer requires minimal maintenance. To ensure longevity and proper function:

  • Te horoi: Wipe the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is off before cleaning.
  • Tirotiro: Periodically check for any signs of damage or loose connections. If any issues are found, disconnect power and consult a qualified electrician.
  • Kaore he waahanga e taea ana e te Kaiwhakamahi: Do not attempt to open or repair the internal mechanism of the timer. This will void any warranty and could lead to electric shock.

Raparongoā

RaruraruTake peaRongoā
Timer does not activate lights.
  • Karekau he hiko ki te ara iahiko.
  • Waea hape.
  • Faulty light bulb/fitting.
  • Timer unit is faulty.
  • Tirohia te wehenga ara iahiko/meka.
  • Verify wiring against installation instructions (ensure power is off).
  • Test light with a known working switch or bulb.
  • Contact customer support if all other checks fail.
Lights do not turn off, or turn off too quickly/slowly.
  • Time delay screw incorrectly set.
  • Mechanism obstructed or under pressure.
  • Adjust the time delay screw on the rear of the unit (see Installation).
  • Ensure the timer is not overtightened or obstructed within the wall box.
Inconsistent timing.
  • Environmental factors (temperature changes).
  • Mechanical wear or obstruction.
  • Pneumatic timers can have slight variations. Re-adjust if necessary.
  • Ensure proper installation and no physical obstructions.

Whakatakotoranga Hua

  • Tauira: 400A
  • Waitohu: Elkay
  • Rauemi: Acrylonitrile Butadiene Styrene (ABS)
  • Tae:
  • Rahi Hua (D x W x H): 2.17" x 3.35" x 3.35" (55mm x 85mm x 85mm te whānui)
  • Taumaha Tūemi: 3.87 ounces (110g approx.)
  • Time Delay Range: Approximately 5 seconds to 5 minutes (adjustable)
  • Momo Whakawhiti: Single Contact, Pneumatic
  • Neutral Requirement: Karekau he kupapa e hiahiatia ana
  • Hototahi rama:
    • Te rama rama
    • Fluorescent lighting (maximum 6 fittings)
  • Tiwhikete: CE, IEC 60669-2-1:2002, RoHS compliant
  • Nga Waahanga Kei roto: 1 x Columbus Pneumatic Timer - Single Contact - 400A

Pūtāhui me te Tautoko Kiritaki

For warranty information or technical assistance, please contact Elkay customer support. Keep your purchase receipt as proof of purchase.

Elkay Customer Support: Please refer to the official Elkay webte pae tukutuku, te takai hua rānei mō ngā taipitopito whakapā.

© 2023 Elkay. Pūmau te mana. Ka taea te whakarerekē i ngā mōhiohio o tēnei pukapuka ā-ringa me te kore panui.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.