User Manual for ENERGETIC LIGHTING models including: E4DL series Recessed Downlight, E4DL series, Recessed Downlight, Downlight

说明书

Model # E4DL series CCT Selectable Recessed Downlight

il y a 6 heures — Please read and understand this entire manual before attempting to assemble, operate or install the product. Failure to do so could lead to electric shock, ...

6 hours ago —

Energetic Lighting E4DL8N17E83040 Instructions/Assembly

E4DL White 1650-Lumen Switchable White Round Dimmable LED Canless Recessed Downlight 845940013662


File Info : application/pdf, 2 Pages, 2.39MB

PDF preview unavailable. Download the PDF instead.

65350064
Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-866-492-6566.
www.energeticlighting.com
Model # E4DL series CCT Selectable
Recessed Downlight

PACKAGE CONTENTS

C

Downlight

B

Input power conduit lead Safety cable

Wire nuts

3

A

D

SAFETY INFORAMTION
Please read and understand this entire manual before attempting to assemble, operate or install the product. Failure to do so could lead to electric shock, fire or other injuries that could be hazardous or even fatal. · Be sure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off
the circuit breaker. · Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment. · This fixture is suitable for triac dimming at 120V.
CAUTION: · The fixture body is one piece. Do not disassemble it. · This unit is intended for indoor use only.

SAFETY INFORMATION
NOTICE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna. - Increase the separation between the equipment and the receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.
WARNING · Minimum Lamp Compartment Dimensions 5.51-in. (Diam) x 7.4-in. (H) · Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical
systems. If not qualified, do not attempt installation. Contact a qualified electrician. · Disconnect power at fuse or circuit breaker before installing or servicing. No user serviceable parts inside.
To avoid electrical shock, do not disassemble product. - This product is not intended for use in emergency light fixtures or exit signs. Not for use where exposed
directly to the weather or water. - This product contains a chemical known to the state of California to cause cancer, birth defects or other
reproductive harm. · Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and
dimensions shown in the photographs and/or drawings. · To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. · Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

PREPARATION
Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product. Estimated Assembly Time: 5 minutes. No tools are required for assembly.

INSTALLATION INSTRUCTIONS
1. Make sure the power is turned off at the source to the recessed housing(s) where the fixtures(s) will be installed.
Remove the existing trim and bulb from the recessed housing fixture.
Open access panel to the conduit junction box (AA).
Ensure that at least one conduit knockout is available to make the input power connection.

AA
Remove Existing trim Ceiling (if available)
Fig. 1

INSTALLATION INSTRUCTIONS
2. Extend the input power conduit lead (B) through ceiling and connect conduit fitting to junction box. Attach the safet cable (C) onto a structural point above the plenum.
Connect the fixture wires to the supply wires -- black to black, white to white, and green to green/bare. WARNING: If there is no ground supply wire, stop installation and consult a qualified electrician.

A
Fig. 2

B C
Ceiling

3a. Before proceeding to the next step, set the desired color temperature (CCT), using the slide switch on the back of the housing. CCT can be changed from 3000K (warm white), 3500K (soft white), to 4000K (cool white).
3000K 3500K 4000K

A
CCT Select Switch

Fig. 3a

4. Carefully tuck all wires into junction box and replace the junction box cover panel. Fold up both spring arms and insert the entire fixture up through the ceiling while letting the tension on the spring arms close onto the upper surface of the ceiling panel. Ensure that the fixture is secured to the ceiling before releasing support of the fixture and completing the installation.

Ceiling

Fig. 4

CARE AND MAINTENANCE
Clean with a mild, non-abrasive glass cleaner and soft cloth. Do NOT use solvents or cleaners containing abrasive agents. When cleaning the fixture, make sure the power is turned off, and any liquid spray should be applied to the cleaning cloth and not sprayed directly onto the fixture itself.
TROUBLESHOOTING

Fixture does not light.
Circuit breaker trips when light is turned on.

1. Power is off. 2. Incorrect wire connection. 3. Defective wall switch.

1. Check circuit breaker or wall switch.
2. Check wire splices. 3. Replace switch.

Crossed wires or power wire is grounded out.

Verify wires are correctly connected.

WARRANTY
This fixture is warranted to perform free from defects for five (5) years. If it fails to do so, you may return it with proof of purchase to 13445 12th St., Chino, CA 91710 for replacement.

