Installation Guide for PXF LIGHTING models including: 12, 16, 18, 28, 24, 27, 33, 36, 37, 46, 65, 40, 57, 82, 44, 55, 62, 57, 78, 80, FIBRA IV LED Tube LED, FIBRA IV LED, Tube LED, LED

Warszawa 19

PXF LIGHTING

FIBRA IV LED INDUSTRY AC FIBRA V LED INDUSTRY AC - pxf.pl

PXF Lighting 73 Jutrzenki Street 02-230 Warsaw tel.: 48 22 33 44 000 1 fax: 48 22 33 44 033 www.pxf.pl INST FIBRA IV LED / INDUSTRY / 24V AC FIBRA V LED / INDUSTRY / 24V AC 220-240V / 50-60Hz 24V/50-60HZ Power [W] L W A H Weight [kg]

Warszawa 19

Fibra IV V LED Installation manual

Instrukcje montażu - PXF Lighting


File Info : application/pdf, 1 Pages, 765.32KB

PDF preview unavailable. Download the PDF instead.

Fibra IV V LED Installation manual
PXF Lighting

tel.: +48 22 33 44 000

1

2

73 Jutrzenki Street

fax: +48 22 33 44 033

02-230 Warsaw

www.pxf.pl

INSTALLATION MANUAL

FIBRA IV LED / INDUSTRY / 24V AC FIBRA V LED / INDUSTRY / 24V AC

3

4

220-240V / 50-60Hz

24V/50-60HZ

Power [W]

L

W

A

H

Weight [kg]

12; 16; 18; 28

615

98

110-370

84

0,9

24; 27; 33; 36; 37; 46; 65 1175 98

700-960

84

1,7

40; 57; 82

1455

98

970-1230

84

2

28; 31; 32; 36

616 145

475

100

1,7

44; 55; 62

1174 145

700

100

3

57; 78; 80

1452 145

940

100

3,9

5

6

Light source used in this luminaire should be changed by the producer or its service representative or similarly qualified person. Installation kit supplied with the luminaire does not include anchors for ceiling installation. Installation kit supplied with the luminaire does not include anchors for ceiling installation.. Classification of insulation maintained between LV power supply and control cables - basic insulation. Provide basic insulation between the LV power supply and control cables.

7
Important warnings: The luminaries may be installed by qualified registered personnel only. Any manipulation inside the luminaire when the power is activated causes the risk of electric shock. The manufacturer is not responsible for any flaws resulting from non-compliance with these instructions. The manufacturer reserves the right to change the construction of the product. Do not install the luminaire in places without sufficient air circulation. To guarantee safe luminaire functioning, please follow the instructions in the installation instructions. PXF Lighting website: www.pxf.pl
The European Directive 2002/96/EC on waste electrical and electronic equipment, requires that electric and electronic devices must be disposed of in the normal household waste. The crossed out wheeled bin is reproduced in order to remind obligations towards separate collection. For correct disposal, please use authorized waste disposal facilities or return to the distributor at the date a new lighting fitting is purchased. Lamps, if disposed together with the lighting fitting, shall not be broken up since they contain substances which are highly polluting to the environment. Unauthorized disposal of the foregoing waste material is punishable by law.



References

Microsoft Word 2010 Microsoft Word 2010