This manual provides comprehensive instructions for the installation, operation, and maintenance of the ECOELER YM2106 Wall Switch Vacancy & Occupancy Sensor. This device is designed to automatically control lighting and motor loads based on motion detection, offering energy savings and convenience. It supports both manual-on (vacancy sensor) and automatic-on (occupancy sensor) switching modes.

Fampahalalana manan-danja momba ny fiarovana

WARNING: RISK OF ELECTRIC SHOCK. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker before installation or servicing. Installation should be performed by a qualified electrician or in accordance with local electrical codes.

  • Vakio ny toromarika rehetra alohan'ny fametrahana azy.
  • Do not install with power on.
  • Ho an'ny fampiasana anatiny ihany.
  • Ensure wiring connections are secure.
  • Operating voltage: 120/277Vac, 60Hz.
  • Neutral wire is not required for operation.

Fonosana fonosana

Hamarino fa misy ny singa rehetra alohan'ny hanombohan'ny fametrahana:

  • ECOELER YM2106 Sensor Switch
  • Rindrin-drindrina (1)
  • Screws
  • Wiring Caps
  • Installation Instruction Manual (this document)

fepetra arahana

Laharana modelyYM2106
BOKYtage120/277Vac, 60Hz
Karazana detectionPIR (Infrared Passive)
mikasika ny180-degrees; 720-square feet
Fanelanelanana fotoana5 seconds to 30 minutes (adjustable)
Ambient Light LevelAdjustable (holds lighting off when natural light is sufficient)
WiringNeutral wire not required
Karazana entanaIncandescent, Fluorescent, LED, CFL
CertificationsUL Listed, Title-24 Compliant
lafiny4.12 x 1.69 x 1.75 santimetatra
KEVITRAPlastic & Metal

Torolàlana fametrahana

Alohan'ny hanombohanao: Turn OFF power at the circuit breaker or fuse box. Ensure the power is completely disconnected before proceeding.

  1. Manomana Wiring: Carefully remove the existing wall switch from the electrical box. Identify the LINE (hot), LOAD, and GROUND wires. The ECOELER YM2106 does not require a neutral wire.
  2. Connect Wires:
    • Connect ny tariby mainty from the sensor to the LINE (hot) wire from the electrical box. Secure with a wiring cap.
    • Connect ny tariby mena from the sensor to the LOAD wire (to the light fixture/motor) from the electrical box. Secure with a wiring cap.
    • Connect ny tariby maitso from the sensor to the GROUND wire from the electrical box. Secure with a wiring cap.
    • Cap off any unused wires in the electrical box, such as a neutral wire, if present.
  3. Mametraka ny sensor: Gently fold the wires into the electrical box. Insert the sensor into the electrical box and secure it with the provided screws.
  4. Mametraka takelaka rindrina: Attach the decorative wall plate over the sensor and secure it.
  5. Ampodio hery: Avereno ny herinaratra amin'ny fiatoana.
  6. Fampiasana fitsapana: The green LED indicator light on the sensor will flash when motion is detected, confirming active detection.

Note: If you are unsure about any wiring steps, consult a qualified electrician.

hetsika

The ECOELER YM2106 sensor supports two primary modes of operation: Vacancy (Manual-On) and Occupancy (Automatic-On).

Vacancy Sensor (Manual-On) Mode

In this mode, the lights/motor will only turn ON when you manually press the switch button. Once ON, the sensor will keep the lights/motor ON as long as motion is detected within its coverage area. The lights/motor will turn OFF automatically after no motion is detected for the set time delay.

Occupancy Sensor (Automatic-On) Mode

In this mode, the lights/motor will turn ON automatically when motion is detected within the sensor's coverage area. The lights/motor will remain ON as long as motion is detected and will turn OFF automatically after no motion is detected for the set time delay.

To switch between modes or adjust settings, refer to the "Configuration and Settings" section.

Configuration sy Settings

The ECOELER YM2106 sensor features adjustable settings for time delay, sensitivity, and ambient light level. These adjustments are typically made via small dials or switches located on the sensor itself, often behind the wall plate.

  • Fahatarana ny fotoana: This setting determines how long the lights/motor remain ON after the last detected motion. It is adjustable from 5 seconds to 30 minutes. Adjust clockwise for longer delays, counter-clockwise for shorter delays.
  • Fahatsapana: This controls the sensor's responsiveness to motion. Higher sensitivity detects smaller movements or movements at greater distances. Lower sensitivity requires more significant motion or closer proximity. Adjust as needed to prevent false triggers or missed detections.
  • Ambient Light Level (Photocell): This setting allows the sensor to hold the lights/motor OFF if sufficient natural light is present in the room, even if motion is detected. This feature helps save energy by preventing artificial lighting from turning on unnecessarily. Adjust to your desired light threshold.

Consult the diagrams on the sensor unit itself for the exact location and labeling of these adjustment controls.

fikarakarana

  • Fanadiovana: Periodically wipe the sensor lens with a soft, dry cloth to remove dust or debris that may obstruct detection. Do not use abrasive cleaners or solvents.
  • Fanaraha-maso: Regularly check the sensor and wall plate for any signs of damage or loose connections.
  • Tsy misy ampahany azo ampiasaina amin'ny mpampiasa: The sensor contains no user-serviceable parts. Do not attempt to open or repair the unit.

Fanamboarana

OLANAAntony mety hitrangavahaolana
Lights/Motor do not turn ON.
  • Tsy misy herinaratra miditra amin'ny sensor.
  • Tariby tsy mety.
  • Sensor in Vacancy (Manual-On) mode and not manually activated.
  • Ambient light level setting too high.
  • Voasakana ny lentilan'ny sensor.
  • Zahao ny fanapahana faritra.
  • Verify wiring connections (LINE, LOAD, GROUND).
  • Press the switch button to activate.
  • Adjust ambient light level setting.
  • Madio lens sensor.
Lights/Motor turn ON unexpectedly.
  • Sensor in Occupancy (Automatic-On) mode.
  • High sensitivity setting.
  • Motion from outside coverage area (e.g., HVAC drafts, pets).
  • Switch to Vacancy mode if desired.
  • Ampihena ny fametahana ny fahatsapana.
  • Adjust sensor placement or reduce sensitivity.
Lights/Motor turn OFF too quickly or too slowly.
  • Incorrect time delay setting.
  • Sensor not detecting continuous motion.
  • Adjust time delay setting.
  • Ensure sensor has a clear line of sight to the activity area. Increase sensitivity if necessary.

Warranty sy fanohanana

For warranty information or technical support, please contact ECOELER customer service. Retain your proof of purchase for warranty claims.

Contact information is typically found on the product packaging or the manufacturer's official website.

Fampahalalam-baovao

No product images or official product videos were provided in the source data to embed in this manual.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.