med-fit-LOGOmed-fit 2460 Interferential TENS and EMS Machine

med-fit-2460-Interferential-TENS-and-EMS-Machine-PRODUCT

Product Overview

med-fit-2460-Interferential-TENS-and-EMS-Machine-FIG-1

No Function description

  1. Treatment Mode
  2. EMS/Russ Work State Symbol
  3. Body Part Symbols
  4. EMS/RUSS Work Time
  5. Pulse Rate and Width
  6. SET Symbol
  7. Intensity Channel 1
  8. Intensity Channel 2
  9. Low Battery Symbol
  10. Pause Symbol
  11. Key Locking Symbol
  12. Programme No or Treatment Time

Product Overview

med-fit-2460-Interferential-TENS-and-EMS-Machine-FIG-2

No Function description

  1. LCD Display
  2. Charging Port
  3. ON/OFF
  4. [M] Button – press the [M] button to select the treatment mode.
  5. [+] Button – press the [+] button to increase the intensity
  6. [-] Button – press the [-] button to decrease the intensity
  7. [P] Button – press the [P] button to select the treatment program
  8. [S] Button – press the [-] button to enter the setting mode
  9. [B] Button – press the [B] button to select the treatment mode
  10. Output socket
  11. Belt clip

Charging your device

Before using your device
When using your device for the first time, it is recommended that you place on charge for approximately 2 hours or until the charging light turns green.

  • Charging – Yellow light.
  • Full charge – Green light.
  • The device cannot be used whilst on charge

How to Operate

Device features

  • Auto Lock After 20 seconds the auto-lock feature is activated, this locks the display and intensity level to To prevent accidental adjustments whilst in use to unlock press either of the intensity buttons.
  • Auto Dim The display has a backlit screen after 20 seconds the backlight stops, to re-activate press any button. This feature saves battery power.
  • Pause Feature Whilst using your device you can pause the treatment at any time. To pause press the M button once the pause symbol will flash beneath the timer. Press the M button again to start the treatment.

How to Operate
Setting a preset programme (P1/P2)
We recommend using these programs before setting up a manual program to help familiarise yourself with the device

  • Step 1
    Press the [M] button to choose the required treatment mode.
  • Step 2
    Press the [B] button to choose a body part for treatment.
  • Step 3
    Press the [P] button and choose either P1 (Programme 1) or P2 (Programme 2).
  • Step 4
    Connect the patient leads to the top of the device CH1 / CH2 and connect 2 pads to each patient cable in use. Now apply the self-adhesive pads to the treatment area ready for use. Please note you can use just one channel 2 pads in TENS, EMS and Russian Stimulation. The IF mode is always 2 patient leads and 4 self-adhesive pads.
  • Step 5
    You are now ready to go Press the [+] button (buttons) CH1 / CH2 to increase the intensity level as required

Please note:
All preset programs have a preset time of 20 minutes which cannot be adjusted

Setting a manual program

  • Step 1
    TENS Mode: Press the [M] button to choose the required mode (TENS, EMS, RUSS or IF).
  • Step 2
    Press the [B] button to choose a body part for treatment.
  • Step 3
    Press the [P] button and select U1 (this is for manual adjustments).
  • Step 4
    Now press the [S] button, which allows manual adjustments to be made. Press the [P] button to change from adjusting pulse rate to pulse width and treatment time.To adjust each parameter (Pulse Width, Pulse Rate and Time) use the [+] and [-] buttons of either CH1 or CH2.
  • Step 5
    Once you have set the required parameters press the [S] button which locks in your settings and the screen shows U1.
  • Step 6
    You are ready to increase intensity by using the [+] buttons CH1 / CH2. Your pre-set time will also be displayed during your treatment session

Please note:
You can not adjust parameters until the intensity is set at zero.

TENS Manual Adjustment examples
Follow Step 1, Step 2, and Step 3. The screen below will be as shown

med-fit-2460-Interferential-TENS-and-EMS-Machine-FIG-3

Now press the [S] button the body part will flash and the Freq (Hz) will flashmed-fit-2460-Interferential-TENS-and-EMS-Machine-FIG-34

  • Use the [+] and [-] buttons to adjust the frequency.
  • Press the [P] button to the next parameter pulse width μs and again adjust to the required setting.
  • Press the [P] button again the timer clock flashes, adjusting to the required setting.
  • Now press [S] button and the program is now set.
  • Increase the intensity to the required level by pressing the [+] and [-] buttons.

Treatment Programmes TENS

ModeModeProg No        Pulse Rate Hz         Pluse Width µs        Time             Type
 

 

 

 

 

 

 

 

 

 

TENS

 

Neck

P180-120120-10020Modulation
P24150-20020Modulation
U13520020Continuous
 

Shoulder

P180-10010020Modulation
P210220-26020Modulation
U110015020Burst
 

Back

P110-6020020Modulation
P26-1025020Modulation
U1100/2150/25020Hans
 

Arm

P1225020Continuous
P210015020Burst
U110020020Continuous
 

Hand

P110010020Continuous
P22-1020020Modulation
U160-10020020Modulation
 

Leg

P16-1020020Modulation
P280-120100-12020Burst
U16-20120-10020Modulation
 

Foot

P180-120100-12020Modulation
P22-1020020Modulation
U12-60260-16020Modulation
 

Elbow

P180-120120-10020Modulation
P21205520Continuous
U18010020Continuous
 

Knee

P110015020Burst
P2120100-12020Modulation
U110010020Continuous
 

Ankle

P110015020Burst
P26-5025020Modulation
U18018020Continuous

TENS: U1 Programs can be adjusted to a frequency of 2Hz – 125Hz, pulse width of 50μs – 380μs, and treatment time of 5min – 90min.

Treatment Programmes EMS

ModeModeProg No        Pulse Rate Hz         Pluse Width µs        Time             Type
 

 

 

 

 

 

 

EMS

 

Neck

P13020020Synchronous
P24020020Synchronous
U15020020Synchronous
 

Shoulder

P14520020Synchronous
P25520020Synchronous
U18020020Synchronous
 

Back

P16020020Synchronous
P27020020Synchronous
U18020020Synchronous
 

Arm

P15015020Synchronous
P26015020Synchronous
U18015020Synchronous
 

Hand

P12015020Synchronous
P23015020Synchronous
U14015020Synchronous
 

Leg

P12020020Synchronous
P28020020Synchronous
U12520020Synchronous
 

Foot

P12020020Synchronous
P23020020Synchronous
U14020020Synchronous
 

EMC: The U1 program allows you to adjust the frequency from 20Hz to 125Hz, the pulse width from 50µs to 380µs, the treatment time from 5 minutes to 90 minutes, the ramp-up time from 1 to 9 seconds, and the relaxation time from 1 to 90 seconds.

Treatment Programmes RUSS

ModeModeProg No        Pulse Rate Hz         Pulse Width µs        Time             Type
 

 

 

 

 

 

 

RUSS

 

Neck

P13020020Synchronous
P24020020Synchronous
U15020020Synchronous
 

Shoulder

P14520020Synchronous
P25520020Synchronous
U18020020Synchronous
 

Back

P16020020Synchronous
P27020020Synchronous
U18020020Synchronous
 

Arm

P15020020Synchronous
P26020020Synchronous
U18020020Synchronous
 

Hand

P12020020Synchronous
P23020020Synchronous
U14020020Synchronous
 

Leg

P12020020Synchronous
P28020020Synchronous
U12520020Synchronous
 

Foot

P12020020Synchronous
P23020020Synchronous
U14020020Synchronous
 

RUSS: In the U1 program, the frequency can be adjusted from 20Hz to 125Hz. The treatment time is adjustable from 5 minutes to 90 minutes. The ramp-up time can be adjusted from 1 to 9 seconds. The contraction time can be adjusted from 1 to 90 seconds, and the ramp-down time can be adjusted from 1 to 9 seconds. Additionally, the relaxation time.to 9 seconds. Additionally, the relaxation time.

Treatment Programmes IF

ModeModeProg No        Pulse Rate Hz         Pluse Width µs        Time             Type
 

 

 

 

 

 

 

 

 

 

IF

 

Neck

P11-10010020Modulation
P21-1005020Modulation
U11-1005020Modulation
 

Shoulder

P150-15010020Modulation
P250-1505020Modulation
U150-1505020Modulation
 

Back

P11-5010020Modulation
P21-505020Modulation
U11-505020Modulation
 

Arm

P11-2010020Modulation
P21-205020Modulation
U11-205020Modulation
 

Hand

P11-2010020Modulation
P21-205020Modulation
U11-205020Modulation
 

Leg

P11-8010020Modulation
P21-805020Modulation
U11-805020Modulation
 

Foot

P11-3010020Modulation
P21-305020Modulation
U11-305020Modulation
 

Elbow

P120-4010020Modulation
P220-405020Modulation
U120-405020Modulation
 

Knee

P160-12010020Modulation
P260-1205020Modulation
U160-1205020Modulation
 

Ankle

P110-5010020Modulation
P210-505020Modulation
U110-505020Modulation

IF: In the IF program, the frequency can be adjusted from 1Hz to 125Hz, and the treatment time can be set from 5 minutes to 90 minutes

CONTACT

  • Med-Fit UK Ltd.
  • Unit 8 Martel Court, S. Park Business Park, Hamilton Road, Stockport, SK1 2AF
  • Telephone: 0161 429 7330
  • Email: sales@med-fit.co.uk
  • www.tensmachineuk.com
  • Company registration number 08758741
  • VAT registration number 308286105

Documents / Resources

med-fit 2460 Interferential TENS and EMS Machine [pdf] User Guide
2460, 2460 Interferential TENS and EMS Machine, Interferential TENS and EMS Machine, TENS and EMS Machine, EMS Machine, Machine

References

Leave a comment

Your email address will not be published. Required fields are marked *