MEAN WELL logo100W Railway Single Output DC-DC Converter
RSD-100 series
MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter -

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - qr code https://www.meanwell.com/Upload/PDF/DC-DC_EN.pdf

Features :

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  •  2:1 wide input range
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity
  • 4000VDC I/O isolation
  • Cooling by free air convection
  • Half encapsulated
  • Built-in constant current limiting circuit
  • 1U low profile 36mm
  • All using 105°C long life electrolytic capacitors
  • LED indicator for power on
  • 100% full load burn-in test
  • 3 years warranty

SPECIFICATION

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - table

https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Case Temperature

Input Terminal Pin No. Assignment :

Pin No. Assignment
1 DC INPUT V+
2 DC INPUT V-
3 FG MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter -icon1

Output Terminal Pin No. Assignment :

Pin No. Assignment
1 DC OUTPUT -V
2 DC OUTPUT +V

Block Diagram

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Block Diagram

Input Fuse

There is one fuse connected in series to the positive input line, which is used to protect against abnormal surge. Fuse specifications of each model are shown as below.

Type Fuse Type Reference and Rating
B Time-Lag Conquer UDA-A, 10A, 250V
C Time-Lag Conquer UDA-A, 5A, 250V
D Time-Lag Conquer UDA-A, 3.15A, 250V
  • Input Reverse Polarity Protection
    There is a MOSFET connected in series to the negative input line. If the input polarity is connected reversely, the MOSFET opens and there will be no output to protect the unit.
  • Input Range and Transient Ability
    The series has a wide range input capability. Within ± 30% of rated input voltage, it can be executed at full-load operation and operate properly; with ±40% of rated input voltage, it can withstand that for 1 second.
  • Input Under-Voltage Protection
    If input voltage drops below Vimin, the internal control IC shuts down and there is no output voltage. It recovers automatically when input voltage reaches above Vimin, please refer to the cruve below.

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Voltage Protection

  • Inrush Current
    Inrush current is suppressed by a resistor during the initial start-up, and then the resistor is bypassed by a MOSFET to reduce power consumption after accomplishing the start-up.
  • Hold-up Time
    • EN50155: 2007 version – D type is in compliance with S2 level, while B and C types are in compliance with S1 level at full load output condition. To fulfil the requirements of S2 level, B and C types require de-rating their output load to 70%, please refer to the curve diagrams below.

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Hold up Time

  • EN50155: 2017 version – Comply with S1 level

Output Voltage Adjustment
This function is optional, which the standard product does not have it. If you do need the function, please contact MW for details.

  • Efficiency vs Load & Vin Curve
    The efficiency vs load & Vin curves of each model are shown as below.

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Vin Curve

Parallel and Series Connection

A.Operation in Parallel
Since RSD-100 series don’t have built-in parallel circuit, it can only use external circuits to achieve the redundant operation but not increase the current rating.

  1. Add a diode at the positive-output of each power supply (as shown as below), the current rating of the diode should be larger than the maximum output current rating and attached to a suitable heat sink. This is only for redundant use (increase the reliability of the system) and users have to check suitability of the circuit by themselves.
    MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Connection
  2. When using S.P.S. in parallel connection, the leakage current will increase at the same time. This could pose as a shock hazard for the user. So please contact the supplier if you have this kind of application.

B.Operation in Series
RSD-100 can be operated in series. Here are the methods of doing it:

  1. Positive and negative terminals are connected as shown as below. According to the connection, you can get the positive and negative output voltages for your loads.
    MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Operation in Series
  2. Increase the output voltage (current does not change). Because RSD-100 series have no reverse blocking diode in the unit, you should add an external blocking diode to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below).
    MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Operation in Series1

Overload Protection

If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it’s not suitable to operate within the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it.

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Overload Protection

Over Voltage Protection
The converter shuts off to protect itself when the output voltage drawn exceeds 115~140% of its output rating. It must be repowered on to recover.
LED Indicator
Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED indicator.
Green : normal operation; No signal: no power or failure.
Derating Curve
a.Single unit operation
If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55 as operating under full load condition. It requires 55℃ de-rating output current when ambient temperature is between 55-70 ℃ , please refer to the de-rating curve as below.

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Overload Protection1

Suitable installation methods are shown as below. Since RSD-100 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Overload Protection2

b.Operate with additional iron plate
If it is necessary to fulfil the requirements of EN50155 TX level that operate the unit fully-loaded at 70℃ , RSD-100 series must be installed onto an iron plate on the bottom. The size of the suggested iron plate is shown as below. In order for optimal thermal performance, the iron plate must have an even & smooth surface and RSD-100 series must be firmly mounted at the center of the iron plate.

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - Overload Protection3

The load vs ambient temperature curve is shown as below.

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - AMBIENT TEMPERATURE

Suitable installation methods are shown as below. Since RSD-100 is a semi-potted model, its thermal performances for the following installation methods are similar and share the same derating curve.

MEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter - iron plate

Immunity to Environmental Conditions

Test method Standard Test conditions Status
Cooling Test EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1 Temperature: -40°C Dwell Time: 2 hrs/cycle No damage
Dry Heat Test EN 50155 section 12.2.4 (Column 2, Class TX)
EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX) EN 60068-2-2
Temperature: 70°C / 85°C Duration: 6 hrs/10min PASS
Damp Heat Test, Cyclic EN 50155 section 12.2.5 EN 60068-2-30 Temperature: 25°C-55°C Humidity: 90%-100% RH Duration: 48 hrs PASS
Vibration Test EN 50155 section 12.2.11 EN 61373 Temperature: 19°C Humidity: 65%
Duration: 10 mins
PASS
Increased Vibration Test EN 50155 section 12.2.11 EN 61373 Temperature: 19°C Humidity: 65%
Duration: 5 hrs
PASS
Shock Test EN 50155 section 12.2.11 EN 61373 Temperature: 21 ± 3°C Humidity: 65 ± 5% Duration: 30ms*18 PASS
Low Temperature Storage Test EN 50155 section 12.2.3 (Column 2, Class TX) EN 60068-2-1 Temperature: -40°C Dwell Time: 16 hrs PASS
Salt Mist Test EN 50155 section 12.2.10 (Class ST4) Temperature: 35°C ±2°C Duration: 96 hrs PASS
  • EN45545-2 Fire Test Conditions
Test Items Hazard Level
Items Standard HL1 HL2 HL3
Oxygen index test 455
EN EN ISO 4589-2:1 45-2:2013996
PASS PASS PASS
R22 Smoke density test EN 45545-2:2013 EN ISO 5659-2:2006 PASS PASS PASS
Smoke toxicity test EN 45545-2:2013
NF X70-100:2006
PASS PASS PASS
R24 Oxygen index test EN EN 45545-2:2013 ISO 4589-2:1996 PASS PASS PASS
R25 Glow-wire test EN 45545-2:2013 EN 60695-2-11:2000 PASS PASS PASS
R26 Vertical flame test EN 45545-2:2013 EN 60695-11:2003 PASS PASS PASS

MEAN WELL logoMEAN WELL RSD 100 Series 100W Railway Single Output DC-DC Converter -icon

Documents / Resources

MEAN WELL RSD-100 Series 100W Railway Single Output DC-DC Converter [pdf] Owner's Manual
RSD-100B-5, RSD-100B-12, RSD-100B-24, RSD-100C-5, RSD-100C-12, RSD-100C-24, RSD-100D-5, RSD-100D-12, RSD-100D-24, RSD-100 Series 100W Railway Single Output DC-DC Converter, RSD-100 Series, 100W Railway Single Output DC-DC Converter, Railway Single Output DC-DC Converter, Single Output DC-DC Converter, Output DC-DC Converter, DC-DC Converter, Converter