Features:

  • Constant voltage design
  • Universal AC input
  • Full range
  • Fully encapsulated with IP67 level (Note.7)
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage
  • Fully isolated plastic case
  • Cooling by free air convection
  • 100% full load burn-in test
  • Low cost, high reliability
  • Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices) (Note. 11)
  • 2 years warranty

SPECIFICATION

MODELLPIP1065LPW100.12LPW100.15LPV-100.24LPV-100.36LPIP100.48
OUTPUTDC VOLTAGE5V12V15V24V36V48V
RATED CURRENT12A8.5A6.7A4.2A2.8A2.1A
CURRENT RANGE0 – 12A0 -8.5A0 – 6.7A0 – 4.2A0 – 2.8A0 – 2.1A
RATED POWER60W102W100.5W100.8W100.8W100.8W
RIPPLE & NOISE (max.) Note.280mVp-p120mVp-p120mVp-p150mVp-p150mVp-p150mVp-p
VOLTAGE TOLERANCE Note.3±8.0%±5.0%
LINE REGULATION±1.0%
LOAD REGULATION±6.0%±2.0%
SETUP, RISE TIME Nate2000ms, 25ms /230VAC 2000ms, 25ms /115VAC
HOLD UP TIME (Typ.)50ms/230VAC 14ms/115VAC at full load
INPUTVOLTAGE RANGE NSA90 – 264VAC 127 – 370VDC
FREQUENCY RANGE47 – 63Hz
EFFICIENCY (Typ.)80%185%I87%188%188%189%
AC CURRENT2.2A/115VAC 1.2A/230VAC
INRUSH CURRENT(Typ.)COLD START 75A(twidtht700ps measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT0.25mA/ 240VAC
PROTECTIONOVERLOAD110 – 150% rated output power
Protection type : Hiccup mode, recoversautomatically after fault condition is removed
OVER VOLTAGE5.75 – 6.75V1 13.8 – 16.2V1 17.25 – 20.25V 1 27.6 – 32.4V 1 41.4 – 48.6V 1 55 2 -64 8V
Protection type : Shutdown gip vdtage, re-power on to recover
EWIRONVENTWORKING TEMP.-25 – +70 C (Refer to “Derating Curve”)
WORKING HUMIDITY20- – 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 – +80 C, 10 – 95% RH
TEMP. COEFFICIENT±0.03%tC (0 – 50’C )
VIBRATION10 – 500Hz, 2G 10minflcyde, period for 60min. each Song X, Y, Z axes
SAFETY & EMCSAFETY STANDARDSUL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,BIS IS15885(Note12), EAC TP TC 004,IP67, IEC62368-1 , BS EN/EN62368-1 approved
WITHSTAND VOLTAGEI/P-0/P:3KVAC
ISOLATION RESISTANCEI/P-0/P:>100M Ohms /500VDC / 25C/ 70% RH
EMC EMISSIONCompliance to BS E N/E N55032 (CISPR32) Class B, BS EN/E N61030-3-2 Class A(< 80% load), BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITYCompiance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035,1ight industry level, EAC TP TC 020
OTHERSMTBF4497.1K hrs mi. Teloordia SR-332 (Bellcore); 681.6Khrs min. MI L-H DB K-217F (25C )
DIMENSION190’52’37mm (L’W’H)
PACKING0.63Kg;20pcs/13.6Kg/0.55CUFT
NOTE1.All parameters NOT specialty mentioned are measured at 230VAC input, rated load and 25 (2 of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12′ twisted par-wire terminated with a 0.1 of & 47uf parallel capacitor.
3.Tolerance : includes set up tolerance, line regulation and bad regulation.
4.Denting may be needed under low input voltage. Please check the static characteristics for more details.
5.The power supply is considered as a component that will be operated in combination with timid equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive cn the complete installation again. (as available on https://www.meanwell.com/Upload/PDF/EMI_stalement_en.pdf)
6.Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to inaease of the set up time.
7.Suitable for indoor use or outdoa use withott direct sunlight exposure.
8.The ambient temperature denting of 351C/1000m with fanless models and of 5’C/1000m with fan models for operating altibde higher than 2000m(6600ft).
9.Products sourced from the Americas regions may not have the TUV/B1S/CCC logo. Please contact your MEAN WELL sales for more information.
10.For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDFLED_EN.paf
11.This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)
12.R-41027766 (GZ facbry) only br 12V,24V / R-62002178 (ID factory) br 5V-48V
※ Product Liability Disdamer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
  • Mechanical Specification

MEAN WELL LPV 100 Series Single Output Switching Power Supply - Mechanical Specification

  • Recommend Mounting Direction

MEAN WELL LPV 100 Series Single Output Switching Power Supply - Mounting Direction

  • Block Diagram

MEAN WELL LPV 100 Series Single Output Switching Power Supply - Block Diagram

  • Derating Curve

MEAN WELL LPV 100 Series Single Output Switching Power Supply - Derating Curve

  • Static Characteristics

MEAN WELL LPV 100 Series Single Output Switching Power Supply - Static Characteristics

MEAN WELL LPV 100 Series Single Output Switching Power Supply - icon

Documents / Resources

MEAN WELL LPV-100 Series Single Output Switching Power Supply [pdf] Owner's Manual
LPV-100-5, LPV-100-12, LPV-100-15, LPV-100-24, LPV-100-36, LPV-100-48, LPV-100 Series Single Output Switching Power Supply, LPV-100 Series, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *