100W Single Output Switching Power Supply
LPV- 100 series
User’s Manual http://www.meanwell.com.cn/Upload/PDF/LED_EN.pdf
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Features:
- Constant voltage design
- Universal AC input
- Full range
- Fully encapsulated with IP67 level (Note.7)
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage
- Fully isolated plastic case
- Cooling by free air convection
- 100% full load burn-in test
- Low cost, high reliability
- Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices) (Note. 11)
- 2 years warranty
SPECIFICATION
MODEL | LPIP1065 | LPW100.12 | LPW100.15 | LPV-100.24 | LPV-100.36 | LPIP100.48 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 36V | 48V |
RATED CURRENT | 12A | 8.5A | 6.7A | 4.2A | 2.8A | 2.1A | |
CURRENT RANGE | 0 – 12A | 0 -8.5A | 0 – 6.7A | 0 – 4.2A | 0 – 2.8A | 0 – 2.1A | |
RATED POWER | 60W | 102W | 100.5W | 100.8W | 100.8W | 100.8W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
VOLTAGE TOLERANCE Note.3 | ±8.0% | ±5.0% | |||||
LINE REGULATION | ±1.0% | ||||||
LOAD REGULATION | ±6.0% | ±2.0% | |||||
SETUP, RISE TIME Nate | 2000ms, 25ms /230VAC 2000ms, 25ms /115VAC | ||||||
HOLD UP TIME (Typ.) | 50ms/230VAC 14ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE NSA | 90 – 264VAC 127 – 370VDC | |||||
FREQUENCY RANGE | 47 – 63Hz | ||||||
EFFICIENCY (Typ.) | 80% | 185% | I87% | 188% | 188% | 189% | |
AC CURRENT | 2.2A/115VAC 1.2A/230VAC | ||||||
INRUSH CURRENT(Typ.) | COLD START 75A(twidtht700ps measured at 50% Ipeak) at 230VAC | ||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC | ||||||
LEAKAGE CURRENT | 0.25mA/ 240VAC | ||||||
PROTECTION | OVERLOAD | 110 – 150% rated output power | |||||
Protection type : Hiccup mode, recoversautomatically after fault condition is removed | |||||||
OVER VOLTAGE | 5.75 – 6.75V | 1 13.8 – 16.2V | 1 17.25 – 20.25V 1 27.6 – 32.4V 1 41.4 – 48.6V 1 55 2 -64 8V | ||||
Protection type : Shutdown gip vdtage, re-power on to recover | |||||||
EWIRONVENT | WORKING TEMP. | -25 – +70 C (Refer to “Derating Curve”) | |||||
WORKING HUMIDITY | 20- – 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 – +80 C, 10 – 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%tC (0 – 50’C ) | ||||||
VIBRATION | 10 – 500Hz, 2G 10minflcyde, period for 60min. each Song X, Y, Z axes | ||||||
SAFETY & EMC | SAFETY STANDARDS | UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,BIS IS15885(Note12), EAC TP TC 004,IP67, IEC62368-1 , BS EN/EN62368-1 approved | |||||
WITHSTAND VOLTAGE | I/P-0/P:3KVAC | ||||||
ISOLATION RESISTANCE | I/P-0/P:>100M Ohms /500VDC / 25C/ 70% RH | ||||||
EMC EMISSION | Compliance to BS E N/E N55032 (CISPR32) Class B, BS EN/E N61030-3-2 Class A(< 80% load), BS EN/EN61000-3-3, EAC TP TC 020 | ||||||
EMC IMMUNITY | Compiance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035,1ight industry level, EAC TP TC 020 | ||||||
OTHERS | MTBF | 4497.1K hrs mi. Teloordia SR-332 (Bellcore); 681.6Khrs min. MI L-H DB K-217F (25C ) | |||||
DIMENSION | 190’52’37mm (L’W’H) | ||||||
PACKING | 0.63Kg;20pcs/13.6Kg/0.55CUFT | ||||||
NOTE | 1.All parameters NOT specialty mentioned are measured at 230VAC input, rated load and 25 (2 of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12′ twisted par-wire terminated with a 0.1 of & 47uf parallel capacitor. 3.Tolerance : includes set up tolerance, line regulation and bad regulation. 4.Denting may be needed under low input voltage. Please check the static characteristics for more details. 5.The power supply is considered as a component that will be operated in combination with timid equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive cn the complete installation again. (as available on https://www.meanwell.com/Upload/PDF/EMI_stalement_en.pdf) 6.Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to inaease of the set up time. 7.Suitable for indoor use or outdoa use withott direct sunlight exposure. 8.The ambient temperature denting of 351C/1000m with fanless models and of 5’C/1000m with fan models for operating altibde higher than 2000m(6600ft). 9.Products sourced from the Americas regions may not have the TUV/B1S/CCC logo. Please contact your MEAN WELL sales for more information. 10.For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDFLED_EN.paf 11.This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.) 12.R-41027766 (GZ facbry) only br 12V,24V / R-62002178 (ID factory) br 5V-48V ※ Product Liability Disdamer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
- Mechanical Specification
- Recommend Mounting Direction
- Block Diagram
- Derating Curve
- Static Characteristics
Documents / Resources
![]() | MEAN WELL LPV-100 Series Single Output Switching Power Supply [pdf] Owner's Manual LPV-100-5, LPV-100-12, LPV-100-15, LPV-100-24, LPV-100-36, LPV-100-48, LPV-100 Series Single Output Switching Power Supply, LPV-100 Series, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply |