MEAN WELL LPF-40 Series 40W Constant Voltage Constant Current LED Driver
Features
- Constant Voltage + Constant Current mode output
- Plastic housing with Class II design
- Built-in active PFC function
- Class 2 power unit
- Fully encapsulated with IP67 level
- Typical lifetime>50000 hours
- 5 years warranty
Applications
LED panel lighting
LED downlight
LED decorative lighting
LED tunnel lighting
Moving sign
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
LPF-40 series is a 40W AC/DCLED driver featuring the dual modes constant voltage and constant current output. LPF-40 operates from 90 305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the hign efficiency up to 90%, with the fanless design, the entire series is able to operate for -40C~ +80’C case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for a variety of applications at dry, damp or wet locations.
Model Encoding
Specifications
MODEL | LPF-40-12 | LPF-40-15 | LPF-40-20 | LPF-40-24 | LPF-40-30 | LPF-40-36 | LPF-40-42 | LPF-40-48 | LPF-40-54 | |
OUTPUT | DC VOLTAGE | 12V | 15V | 20V | 24V | 30V | 36V | 42V | 48V | 54V |
CONSTANT CURRENT REGION Note.2 | 7.2 ~12V | 9 ~ 15V | 12 ~ 20V | 14.4 ~ 24V | 18 ~ 30V | 21.6 ~ 36V | 25.2 ~ 42V | 28.8 ~ 48V | 32.4 ~ 54V | |
RATED CURRENT | 3.34A | 2.67A | 2A | 1.67A | 1.34A | 1.12A | 0.96A | 0.84A | 0.76A | |
RATED POWER Note.5 | 40.08W | 40.08W | 40W | 40.08W | 40.2W | 40.32W | 40.32W | 40.32W | 41.04W | |
RIPPLE & NOISE (max.) Note.3 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 250mVp-p | 250mVp-p | 250mVp-p | 350mVp-p | |
VOLTAGE TOLERANCE Note.4 | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | ±4.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±2.0% | ±1.5% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME Note.6 | 1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC | |||||||||
HOLD UP TIME (Typ.) | 16ms/230VAC 16ms/115VAC | |||||||||
INPUT | VOLTAGE RANGE Note.5 | 90 ~ 305VAC 127 ~ 431VDC (Please refer to “STATIC CHARACTERISTIC” section) | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
POWER FACTOR | PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load (Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section) | |||||||||
TOTAL HARMONIC DISTORTION | THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) | |||||||||
EFFICIENCY (Typ.) | 84% | 85% | 86% | 87% | 88% | 88% | 88.5% | 90% | 90% | |
AC CURRENT | 0.6A / 115VAC 0.3A / 230VAC 0.25A/277VAC | |||||||||
INRUSH CURRENT(Typ.) | COLD START 50A(twidth=210μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC | |||||||||
LEAKAGE CURRENT | <0.75mA / 240VAC | |||||||||
PROTECTION | OVER CURRENT | 95 ~ 108% | ||||||||
Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 15 ~ 17V | 17.5 ~ 21V | 23 ~ 27V | 28 ~ 35V | 34 ~ 40V | 41 ~ 49V | 46 ~ 54V | 54 ~ 63V | 59 ~ 66V | |
Shut down and latch off o/p voltage, re-power on to recover | ||||||||||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |||||||||
ENVIRONMENT | WORKING TEMP. | Tcase=-40 ~ +80℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) | ||||||||
MAX. CASE TEMP. | Tcase=+80℃ | |||||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80℃, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | |||||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
SAFETY & EMC | SAFETY STANDARDS Note.8 | UL8750, CSA C22.2 No. 250.0-08, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384,EAC TP TC 004, IP67, J61347-1, J61347-2-13,GB19510.1,GB19510.14 approved ; design refer to UL60950-1 | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH | |||||||||
EMC EMISSION Note.8 | Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3, GB17743 and GB17625.1,EAC TP TC 020 | |||||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV), EAC TP TC 020 | |||||||||
OTHERS | MTBF | 3597.9K hrs min. Telcordia SR-332 (Bellcore) ; 438.9Khrs min. MIL-HDBK-217F (25℃) | ||||||||
DIMENSION | 162.5*43*32mm (L*W*H) | |||||||||
PACKING | 0.44Kg; 32pcs/15.08Kg/0.93CUFT | |||||||||
Note: | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 C of ambient temperature. 2. Please refer to “DRIVING METHODS OF LED MODULE”. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire teminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance: includes set up tolerance, line regulation and load regulation. 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details. 6. Length of set up time is measured at first cold start. Turning ONOFF the driver may lead to increase of the set up time. 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 3. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without pemanently connected to the mains. 9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly t point (or TMP, per DLC), is about 75C or less. 10. Please refer to the warranty statement on MEAN WELLs website at http://www.meanwell.com 11. The ambient temperature derating of 3.5 C/1000m with fanless models and of 5 C/1000m with fan models for operating altitude higher than 2000m(6500f). 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf xProduct Liability Disclaimer: For detailed information please refer to https://www.meanwell.com/serviceDisclaimer.aspx |
Block Diagram
DRIVING METHODS OF LED MODULE
This series is able to work in either Constant Current mode (a direct drive way) or Constant Voltage mode (usually through additional DC/DC driver) to drive the LEDs.
OUTPUT LOAD vs TEMPERATURE 
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
※De-rating is needed under low input voltage
TOTAL HARMONIC DISTORTION (THD)
48V Model, Tcase at 70℃
EFFICIENCY vs LOAD
LPF-40 series possess superior working efficiency that up to 90% can be reached in field applications
※ 48V Model, Tcase at 70℃
LIFE TIME 
MECHANICAL SPECIFICATION
Recommend Mounting Direction
INSTALLATION MANUAL
Please refer to:http://www.meanwell.com/manual.html
Documents / Resources
![]() | MEAN WELL LPF-40 Series 40W Constant Voltage Constant Current LED Driver [pdf] Instruction Manual LPF-40 Series 40W Constant Voltage Constant Current LED Driver, LPF-40 Series, 40W Constant Voltage Constant Current LED Driver |
![]() | MEAN WELL LPF-40 Series 40W Constant Voltage + Constant Current LED Driver [pdf] User Manual LPF-40 Series 40W Constant Voltage Constant Current LED Driver, LPF-40 Series, 40W Constant Voltage Constant Current LED Driver, Constant Voltage Constant Current LED Driver, Voltage Constant Current LED Driver, Constant Current LED Driver, Current LED Driver, LED Driver, Driver |