MEAN WELL NPB-120 120W Compact Size and Wide Output Range Charger Instructions
MEAN WELL NPB-120 120W Compact Size and Wide Output Range Charger

Features

Features

  • 90~264Vac universal AC input, built-in PFC
  • Charger for compatible with lead-acid and Ii-ion batteries
  • Fan less design
  • Wide adjustable output range by VR:
  • Charging voltage adjustable(1 0.5~ 15.2V, 21 ~30.4 V, 42~60.8V
  • Charging current adjustable(50~100% rated current
  • 2 or 3 stage selectable by DIP S.W
  • No load power consumption< 0.15W(AC S.W off)
  • -30°C ~+ 70°C wide operating temperature
  • Protections: Short circuit/ Over voltage /Over temperature/
    Battery reverse polarity protection
  • Comply with UL/EN62368-1 and EN60335-1/2-29 dual certification
  • Front panel LED indicator for charging status
  • 3 years warranty

Applications

Applications

  • Radio system backup solution
  • Electric scooter charger
  • Camping car, Buses, Heavy duty truck, Specialty vehicles
  • Surveillance system
  • Portable power tools

Description

NPB-120 series is a 120W charger for compatible with lead-acid (Flooded, Gel, AGM) and li-ion(Lithium iron, lithium manganese) batteries. This product is a class I power unit (with FG), equipped with a standard IEC320-C14 AC inlet and two or three-stage charging control. The entire series supplies different models with output voltages ranging between 10.5VDC and 60.8VDC that can satisfy the demands for various types of batteries devices.

Model Encoding

Model Encoding

Type Output Connector   Safety Note
XLR 3 pin power pin

Output Connector

Safety icon
(48V UL certificated same as TB Type)
Safety icon
In Stock
AD1 Anderson connector

Output Connector

In Stock
TB Terminal Block

Output Connector

In Stock

SPECIFICATION

MODEL NPB-120-12 NPB-120-24 NPB-120-48
=XLR, AD1, TB
OUTPUT BOOST CHARGE VOLTAGE(V boost) default) 14.4V 28.BV 57.6V
FLOAT CHARGE VOLTAGE(V float)l default) 13.BV 27.6V 55.2V
VOLTAGE ADJUSTABLE RANGE 10.5-15.2V 21 – 30.4V 42 – 60.8V
OUTPUT CURRENT(Typ.) Note.5 6.8A 4A 2A
CURRENT ADJUSTABLE RANGE 50% -100%
MAX. POWER               Note.3 103.4W 121.6W 121.6W
RECOMMENDED BATTERY CAPACITY (AMP HOURS) Note.4  

20 – 90AH

 

15 – 50AH

7- 25AH
INPUT VOLTAGE RANGE        Note.5 90 – 264VAC        127- 370VDC
FREQUENCY RANGE 47 – 63Hz
POWER FACTOR (Typ.) PF>0 .98/115VAC, PF>0 .92/230VAC@12V,PF>0.93/230VAC@24/48V       at full load
EFFICIENCY (Typ.) XLR 86.5% 89% 90.5%
AD1 86.5% 89% 90.5%
TB 87% 89.5% 90.5%
AC CURRENT (Typ.) 1.5A/115VAC         0.8A/230VAC
INRUSH CURRENT (Typ.) COLD START 55A at 230VAC
PROTECTION SHORT CIRCUIT          Note .6 Protection type : Constant current limiting , charger will shutdown after 5 sec, re-power on to recover
 OVER VOLTAGE 16- 20V 32-40V 64- 75V
Protection type : Shut down and latch off o/p voltage , re-power on to recover
REVERSE POLARITY By internal fuse open
OVER TEMPERATURE Hiccup mode, recovers automatically after temperature goes down
FUNCTION CHARGING CURVE 2 or 3 stage adjustable by DIP S.W
ENVIRONMENT WORKING TEMP. -30 – +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY 20 – 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 – +85°C, 1 0 – 95% RH non-condensing
TEMP. COEFFICIENT ±0.05%/°C (0 – 45°C)
VIBRATION 10-500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
 

 

 

 

 

 

 

 

 

SAFETY &EMC (Note 7)

SAFETY STANDARDS CB IEC62368-1 ,IEC60335-1/2-29, Dekra BS EN/EN62368-1 ,BS EN/EN60335-1/2-29, UL62368-1 , EAC TP TC 004 approved
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, 1 /P-FG , O/P-FG:100M Ohms/ 500VDC / 25°C/ 70% RH
 

EMC EMISSION

Parameter Standard Test Level I Note
Conducted BS ENIEN55032 (CISPR32),BS EN/EN55014-1 Class B
Radiated BS EN/EN55032 (CISPR32),BS EN/EN55014-1 Class B
Harmonic Current BS ENIEN61000-3-2 Class A
Voltage Flicker BS ENIEN61000-3-3 —–
EMC IMMUNITY BS EN/EN55014-2,BS ENIEN55024,BS EN/EN55035
Parameter Standard Test Level I Note
ESD BS ENIEN61000-4-2 Level 3, 8KV air ; Level 2, 4KV contact
Radiated BS EN/EN61000-4-3 Level 2, 3V/m
EFT/ Burst BS ENIEN61000-4-4 Level 2, 1KV
Surge BS ENIEN61000-4-5 Level 2, 1KV/L ine- Line. Level 3, 2KV/Line-Earth
Conducted BS EN/EN61000-4-6 Level 2, 3Vrms
Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m
Voltage Dips and Interruptions BS ENIEN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS MTBF 631.BK hrs min.   Telcordia TRISR-332 (Bellcore);  225.BK hrs min.    MIL-HDBK-217F (25′ C)
DIMENSION 180’96’49mm (L’W’H)
PACKING 1.3Kg; 1Opes/ 14Kg / 1.13CUFT
 

 

 

 

 

NOTE

  1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
  2. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
  3. Refer to derating curve.
  4. This is MEAN WELL’s suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
  5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. This protection mechanism is specified for the case the short circuit oocurs after the charger is turned on.
  7. The charger is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http//www.meanwell.com)

Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.corn/serviceDisclaimer.aspx

Block Diagram

Block Diagram

Derating Curve

Derating Curve

Static Characteristics

Static Characteristics

Charging Curve

2 or 3 stage selectable by DIP S.W

This series provides 2 or 3 stage charging curve.(Default 3 stage)
Charging instruction

Charging Curve by DIP S.W

2 stage charging curve
Charging instruction

State NPB-120-12 NPB-120-24 NPB-120-48
Constant Current 6.8A 4A 2A
Vtloat 13.8V 27.6V 55.2V

3 stage charging curve
Charging instruction

State NPB-120-12 NPB-120-24 NPB-120-48
Constant Current 6.8A 4A 2A
V boost 14.4V 28.8V 57.6V
V tloat 13.8V 27.6V 55.2V

2 stage charging cure is suitable for Li-ion batteries(lithium iron and lithium manganese),
3 stage charging cure is suitable for lead-acid batteries (flooded ,Gel and AGM).

Charging voltage adjustable by VR

Icon

Model NPB-120-12 NPB-120-24 NPB-120-48
Output voltage adjustable range 10.5- 15.2V 21-30.4V 42-60.BV
Charging current adjustable by VR

Icon

Model NPB-120-12 NPB-120-24 NPB-120-48
Output current adjustable range 3.4-6.8A 2-4A 1-2A
Front panel LED indicators & Corresponding signal at function pins

Icon

LED Description
Icon Green Float (stage 3) or Battery full
Icon  Red Charging (stage 1 or stage 2)

Mechanical Specification

NPB-120-xxXLR/AD1 (Cable Type)
Mechanical Specification

NPB-120-xxTB (Terminal Block Type)
Mechanical Specification

Plug Assignment

Standard Output Connector
Standard Output Connector

Optional DC plug: (Available in customized)

Min. DIN 4 Pin with Lock (male) Type No. Pin Assignment
PIN No. Output( <7A)
Operation instruction  

R?B

1 +Vo
2 -Vo
3 -Vo
4 +Vo
DIN 4 Pin XLR Type No. Pin Assignment
PIN No. Output(< 10A)
Operation instruction XLR4 1 +Vo
2 +Vo
3 -Vo
4 -Vo
DIN 3 Pin Type No. Pin Assignment
PIN No. Output(<7A)
Operation instruction  

03P

1 +Vo
2 -Vo
3 -Vo
DIN 2 Pin Type No. Pin Assignment
PIN No. Output(<5A)

Operation instruction

 

02P

   

-Vo

 

2

 

+Vo

DIN 3 Pin Type No. Pin Assignment
PIN No. Output(< 10A)

Operation instruction

 

INL3

 

N

 

+Vo

 

L

 

-Vo

AMP 1-480702-0 (6.35mm) equivalent Type No. Pin Assignment
PIN No. Output( <7A)

Operation instruction
FG not connected to output connector

 

C4P

1 +Vo
2 +Vo
3 -Vo
4 -Vo

INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html

Documents / Resources

MEAN WELL NPB-120 120W Compact Size and Wide Output Range Charger [pdf] Instructions
NPB-120, 120W Compact Size and Wide Output Range Charger, Wide Output Range Charger, Range Charger, 120W Compact Size Charger, Charger

References

Leave a comment

Your email address will not be published. Required fields are marked *