30W Single Output for Medical Type
M P S – 3 0 series
Features
- Universal AC input / Full range
- Low leakage current <200pA
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Medical safety approved (2 x MOPP between primary to secondary)
- Fixed switching frequency at 100KHz
- Low cost
- High reliability
- 3 years warranty
SPECIFICATION
MODEL | MPS-30-5 | MPS-30.12 | MPS-30-15 | MPS-30-24 | MPS-30-27 | MPS-30-48 | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 27V | 48V |
RATED CURRENT | SA | 2.5A | 2A | 1.2A | 1.1A | 0.6A | |
CURRENT RANGE | 0 – 5A | 0 – 2.5A | 0 – 2A | 0 – 12A | 0-1.1A | 0 – 0.6A | |
RATED POWER | 25W | 30W | 30W | 28.8W | 29.7W | 282W | |
RIPPLE & NOISE (ma) Note.2 | 80mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | 240mVp-p | 240mVp-p | |
VOLTAGE TOLERANCE Note.3 | i 3.0% | r 3.0% | 13.% | 13.% | 13.% | 12.% | |
LINE REGULATION | 11.% | 11.% | 11.% | 11.% | 11.% | 11.% | |
LOAD REGULATION | 12.% | -1.% | 11.% | 1.1.0% | 11.% | 11.% | |
SETUP, RISE TIME | 500ms. 30ms/230VAC SOOms. 30ms/115VAC at ful load | ||||||
HOLD UP TIME (Typ.) | 70ms/230VAC 12ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 88 – 264VAC aub switch 120 – 370VDC | |||||
FREQUENCY RANGE | 47 – 63Hz | ||||||
EFFICIENCY (Typ.) | 72% I 75% 178% 177% I 78% 178% | ||||||
AC CURRENT (Typ.) | 0.8A1115VAC 0.5A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 30N230VAC | ||||||
LEAKAGE CURRENT | Earth leakage current < 20001264VAC | ||||||
PROTECTION | OVERLOAD | Above 105% rated output power | |||||
Protection type: Hiccup mode. recovers automatically after the fault condition is removed | |||||||
OVERVOLTAGE | 5.5 -6.75V 1 132 – 18.2V 1 16.5 -2025V 1 26.4 -32.4V 1 29.7 – 36.45V 1 52.8 – 64.8V | ||||||
Protect= type : Hiccup mode. recovers automatically after the fault condition is removed | |||||||
OVER TEMPERATURE | Shut down of voltage. re-power on to recover | ||||||
EIMRONNENT | WORKING TEMP. | -10 – •60 C (Refer to ‘berating Curve’) | |||||
WORKING HUMIDITY | 20- 90% RH non-condensing | ||||||
STORAGE TEMP.. HUMIDITY | -20- •85 C.10 – 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%1C (0 – 50t) | ||||||
VIBRATION | 10- 500Hz. 2G 10mindlcycle. period for 60min. each along X. Y.Z axes | ||||||
SA TY &FE EMC (Note 4) | SAFETY STANDARDS | ANSI/MMI E560601-1. TUV EN60601-1.1E080601-1 approved | |||||
ISOLATION LEVEL | Primary-Secondary: 2xMOPP. Primary-Earth:1 xMOPP | ||||||
WITHSTAND VOLTAGE | VP-0/P:IKVAC IIP-FG2KVAC OiP-FG:SHORT | ||||||
ISOLATION RESISTANCE | 1/P-011s, I/P-FG:100M Ohms / 500VDC / 25C/ 70% RH | ||||||
EMC EMISSION | Compliance to EN55011 (CISPR11) Class B. EN61000-3.2.-3 | ||||||
EMC IMMUNITY | Compliance to EN61000-4-22.4.5.6.8.11.EN55024.EN60601.1-2. medical level. criteria A | ||||||
OTHERS | MTBF | 547Khrs min. ML-HDBK-217F(2512) | |||||
DIMENSION | 101.6’65.8’23.5mm (12WIH) | ||||||
PACKING | 0.16Kg: 90pcs/15.8Kg11.06CUFT | ||||||
NOTE | I. AI parameters NOT specially mentioned are measured at 230VAC Mal rated load and 26-c cr ambient temperature. 2 Ripple & noise are measured at 2014H2 of bandwidth by usrg it twisted pa ‘woe terminated with a 0.1u18 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation, and load regJabcn. 4. The power supply is considered a component that will be instated into the final equipment. Al the EKE tests are been executed by mounting the unit on a 36Orrrn*360mm metal plate with Imm of thickness. The foal equipment must be re-confirmed that it sat meets EMC directives. For guidance on how to perform these EMC tests. please refer to ‘EMI testing of component power supplies: (as eyelet: Ile on herps:/www.menwell.com 5. When the input voltage s Ic6s than 40VAC. the SPS may exhibit degradation of performance. The final product manufacturers must re-confirm xis deviation that does not affect basic safety or essential performance. -‘.. Product Lialolly Osclaimer For detailed information. please refer to herps:/www.menwell.com/serviceDisclaimer.aspx |
Mechanical Specification
Unit:mm
Block Diagram
Derating Curve
Static Characteristics
https://www.meanwell.com/Upload/PDF/Medical_EN.pdf
Documents / Resources
![]() | MEAN WELL MPS-30 Series 30W Single Output for Medical Type [pdf] Instruction Manual MPS-30 Series 30W Single Output for Medical Type, MPS-30 Series, 30W Single Output for Medical Type, Medical Type |