MASTECH MS2203 Three-Phase Power Clamp Meter
Safety instruction
Special attention should be paid when using the test and measurement instrument because the improper usage may cause electric shock and damage the equipment.
- Use proper measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
- Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
- When handling the test probes and crocodile clips, keep your fingers behind the physical guard.
- Examine the measuring test leads (if present) before use. Any element of which the insulation deteriorates (even partially), replace them with proper functional test leads.
- Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
- Before measuring the current, make sure the instrument fuses available and disconnect the power supply to the circuit test
- Remove the batteries if the device is not used for an extended period of time, or if stored in temperatures above 45 °C. If the batteries are not removed, battery leakage can damage the device.
Contents
Specifications
S/ pХаeрciаfiкcтaеtрioиnсsти/Eкsиpecificaciones /Caractéristiques / 規格 / 規格 | |||
V~ A~ kW kVA
kVAr PF kWh
Hz | Range Rango Intervalle 量測程定レンジ Диапазон
100V/300V/600V
40A/100A/400A/1000A
4kW/10kW/40kW/100kW 600kW
4kVA/10kVA/40kVA/100kVA/ 600kVA
4kVAr/10kVAr/40kVAr/100kVAr 600kVAr
0.3~1
1kWh~9999kWh
20Hz~1000Hz | Resolution Resolución Résolution 解像析度 Разрешение
0.1V
0.1A/0.1A/0.1A/1A
0.01kW 0.1kW
0.01kVA 0.1kVA
0.01kVAr 0.1kVAr
0.001
0.001kWh
0.1Hz | Accuracy Exactitud Précision準正精度確度Точность
±(1.2%+5)
±(2.0%+5)
±(3.0%+5) ±(3.0%+5)
±(3.0%+5) ±(3.0%+5)
±(4.0%+5) ±(4.0%+5)
±(2.0%+2)
±(3.0%+2)
±(0.5%) |
CHARGING
SINGLE-PHASE -3PHASE 4 WIRE-3PHASE 3WIRE