Home » Mahr » Mahr P2010 MB Series Inductive Probe Owner’s Manual 

Mahr P2010 MB Series Inductive Probe
FEATURES
- Models with or without compressed air (pneumatic) lifter or vacuum retraction
- Measuring pin mounted in ball-bearing guide
- High linearity over the entire measuring range
- Excellent electromagnetic shielding (EMC)
- All probes can be easily converted from axial to radial by mounting a slip-on cap (included)
- Chemical resistance data: resis-tant to oil, gasoline, water and aliphatics. Moderately resistant to acids, bases, solvents and ozone
- Package contains: instruction manual, cap for radial cable output, spanner for preliminary stroke setting
TECHNICAL DATA
Order no. 5324030 5324031 5324033 5324034 |
Product type | | P2010 MB | P2010 TB | P2010 UB | P2010 FB |
Measuring range | mm | ± 5 |
Measuring range | inch | ± .197“ |
Distance to upper stop | mm…mm | +5.3 |
Distance to upper stop | inch…inch | + .20“ |
Distance to lower stop | mm…mm | –5.3 |
Distance to lower stop | inch…inch | –.20“ |
Lifter / retraction | | Compressed air retraction (max. 1 bar) |
Measuring force | N | Depending upon air pressure |
Sensitivity deviation | % | 0.3 |
Repeatability fw | µm | 0.2 |
Repeatability fw | inch | 8 µ“ |
Hysteresis fu | µm | 1 |
Hysteresis fu | inch | 40 µ“ |
Linearity deviation within +/–2.0 mm | µm | 4 |
Linearity deviation within +/–.079“ | inch | 160 µ“ |
Linearity deviation within +/–5.0 mm | µm | 20 |
Linearity deviation within +/–.197“ | inch | 200 µ“ |
IP protection category | | IP 64 |
Cable length | m | 2.5 |
Temperature coefficient | µm/°C | 0.15 |
Compatibility | | Mahr VLDT | Tesa | Marposs | Federal |
Dimension
Order no. g Dimension f j k l m a b c d e f h i |
| | inch | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
5324030 | M 2.5 | | 3.6 | 9 | 8.3 | 12.5 | 125.7 | 28 | 34 | 6 | 9.2 | 8 | 14 | 26.5 |
5324031 | M 2.5 | | 3.6 | 9 | 8.3 | 12.5 | 125.7 | 28 | 34 | 6 | 9.2 | 8 | 14 | 26.5 |
5324033 | M 2.5 | | 3.6 | 9 | 8.3 | 12.5 | 125.7 | 28 | 34 | 6 | 9.2 | 8 | 14 | 26.5 |
5324034 | 4/48 UNF | 0.375 | 3.6 | 9 | 8.3 | 12.5 | 125.7 | 28 | 34 | 6 | 9.2 | | 14 | 26.5 |

FAQ
- Q: What is the maximum air pressure for retraction?
A: The maximum air pressure for retraction is 1 bar. - Q: What IP rating does the probe have?
A: The probe has an IP rating of IP 64, indicating protection against dust and water splashes. - Q: How do I ensure accurate measurements with the probe?
A: To ensure accurate measurements, make sure the probe is securely connected, maintain stable contact during measurement, and perform regular maintenance checks.