Experience the power and efficiency of Macro Air’s AVD5, a cutting­ edge direct-drive fan for industrial and commercial spaces. The captivating five-blade AVD5 is a perfect composition of purposeful design, superior  performance, and cost efficiency. Elevate your projects with the AVD5, a commanding revelation in air movement.

STANDARD FEATURES:

  • 1.0 HP (equivalent) Direct Drive motor, rated for indoor/outdoor use*
  • Clearcoat anodized airfoil blades
  • Industry leading onboard electronics for unmatched reliability
  • Forward, reverse, variable speed
  • Integrated VFD/Mount Enclosure
  • Safety Components: safety cable, Universal Mount with guy wires, blade retainer links

MacroAir AVD5 Ceiling Fan Khinds Systems - fig

MacroAir AVD5 Ceiling Fan Khinds Systems - icon Pending AMCA Certification
MacroAir AVD5 Ceiling Fan Khinds Systems - icon1*Pending Conformity to UL Std 507
Certified to CSA Std C22.2 No, 113
STEP 1: 

STEP 1:POWER UNIT
Item #OptionsQty
M500-0025-MA8-14 ft Power Unit, 1.0 HP Equivalent
M500.0035-MA16-18 ft Power Unit, 1.0 HP Equivalent
M500-0050-MA20-24 ft Power Unit, 1.0 HP -suivalent
STEP 2: BLADES
Item #DiameterQty
60-80008-008 ft / 2.44 m
60-80010-0010ft/ 3.05m
60-80012-0012ft/ 3.66m
60.80014-0014ft/4.27m
60-80016-00int/Assn
60-80018-001811/5.49m
6040020-0020 ft / 6.07 m
60-80024-0024 ft / 7.32 m
STEP 3:VOLTAGE/PHASE
Item #
33.21017-00
OptionsQty
208.240V Single Phase, 50/60 Hz AVD5 DROP ENCL (for use with Universal Mount)
33-21038-00208-240V Three Phase, 50/60 Hz AVD5 DROP ENCL (for use with Universal Mount)
33.41038-00480V Three Phase, 50/60 Hz AVD5 DROP ENCL (for use with Universal Mount)
35-21017-00208.240V Single Phase, 50/60 Hz AVD5 SCHNEIDER CONT PNL (for use with Rapid Mount Industrial)
35-21038-00208-240V Three Phase, 50/60 Hz AVD5 SCHNEIDER CONT PNL (for use with Rapid Mount Industrial)
35-41038-00 480V Three Phase, 50/60 Hz AVD5 SCHNEIDER CONT PNL (for use with Rapid Mount Industrial)
STEP 4:MOUNTING
Item #OptionsQty
60-50150-00AVD Universal Mount with I-beam Hardware Kit
60-40049-00Glulam Hardware Kit
60-50136-00Rapid Mount Industrial with I-Beam Hardware Kit (requires drive in control panel, offboard)
STEP 5 CONTROLS
Item #DescriptionQty
30-90308-00Digital Remote Assembly (Standard)
30-04006-00Controller 4
30040117-00Controller 4+ Single Temperature Sensor
30-04030-01Controller 30
30-10012-00AirLynk – BacNet
30-10011-00AirLynk – Lon works
304403002Dual Control Enabled Controller 30 (requires AirLynk-BacNet)
STEP 6 STOCK DROP LENGTHSLength (m)Qty
:tern #
5140200-02
Length (ft/in)*
2 ft•0.61 m
51-X0300-023 ft (Standard)0.91 m
51-X0400-024 ft1.22 m
51-X0500-025 ft1.52 m
51-X0600-026 ft1.83 m
51-X0700-027 ft2.13 m
51-X0800-028 ft2.44 m
51-X0900-029 ft2.74 m
51-X1000-0210 ft3.05 m
51-F1tin-02Customization fee

• Lengths are+- 1″ depending on power unit selection/fan diameter.
X= substitute D for drops with UMH mount, F for drops with Rapid Mount Industrial (i.e. 51-F0500-02 describes a 5′ drop for use with a Rapid Mount Industrial).
ft = length n feet (i.e. 04 for 4 feet, 10 for 10 feet)
n = length in inches (i.e. 05 for 5 inches, 10 for 10 niches)
**2 ft is the shortest allowed drop length for AVD5. Lengths shorter than the standard drop length are not recommended and will not work for some fan diameters. Consult MacroAir for more details.
DROP LENGTH is the distance from fan mounting point to the blades.
AVD5 fans can only be connected with a single-piece of custom length drop tube.
Measure the distance from the fan’s mounting point down to the desired fan blade position and provide this information with the fan order to receive the correct custom drop length.
For custom drop lengths, order a length longer and Macro Air will cut it down to the requested length. Estimated lead time is 10 business days.
Do you have a custom color in mind? Custom powder coating is available for all our blades, mounts and drop lengths.

OPTIONAL: POWDER COATING
Item #DiameterEstimated Lead TimeQty
60-80008-028 ft / 2.44 m15 business days
60-80010-0210 ft / 3.05 m15 business days
60-80012-0212 ft / 3.66 m15 business days
60-80014-0214 ft / 4.27 m15 business days
60-80016-0216 ft / 4.88 m15 business days
60-80018-0218 ft / 549 m15 business days
60-80020-0220 ft / 6.07 m15 business days
60-80024-0224 ft / 7.32 m15 business days

ADDITIONAL OPTINS

Item #DescriptionQty
1 0-60200-00AVD Fuse Disconnect*

*IEC Compliance requires a fused disconnect switch. Fuse selection is input voltage specific, so fuses are not provided w th purchase of a disconnect.

BASIC SPECIFICATIONS

MacroAir AVD5 Ceiling Fan Khinds Systems - fig1

“For spacing between fan units based on the dimensions of a specific space please refer to https://macroairfans.com/airviz.
**Sound testing taken with the sensor 5 ft above the ground and 20 ft from the center of the fan at 20 ft high. Carrier frequency will be audible to some listeners and s considered normal during operation.
Supplemental nformation on Carrier Frequency and Decibel levels are supplied with the full product selection guide.
***Applicable to the fan unit only, does not include controller, control panel and accessories.

MacroAir logo© 2024 MacroAir Technologies, Inc.
ST TOM Sets RCP Wl
macroairfans.com
Rev. 05.16.2024

Documents / Resources

MacroAir AVD5 Ceiling Fan Khinds Systems [pdf] Instructions
AVD5 Ceiling Fan Khinds Systems, AVD5, Ceiling Fan Khinds Systems, Fan Khinds Systems, Khinds Systems, Systems

References

Leave a comment

Your email address will not be published. Required fields are marked *