Weight per Unit. Component. 84.0 lb (38.2 kg). Cisco Nexus 9504 Chassis (N9K-C9504). —. Supervisor Modules. 4.84 lb (2.2 kg). Supervisor A module (N9K-SUP-A).
System Specifications · Environmental Specifications, on page 1 · Switch Dimensions, on page 1 · Weights for the Chassis, Modules, Fan Trays, and Power Supplies, on page 2 · Power Specifications, on page 3 Environmental Specifications Environment Temperature Ambient operating temperature Ambient nonoperating Relative humidity Operating Nonoperating Altitude Operating Specification 32 to 104°F (0 to 40°C) 40 to 158°F (40 to 70°C) 5 to 90% 5 to 95% 0 to 13,123 feet (0 to 4,000 meters) Switch Dimensions Chassis or Module Width Depth Height Cisco Nexus 9504 chassis 17.5 inches (44.5 cm) 33.15 inches (84.20 cm) 12.25 inches (31.1 cm) (7 for chassis and handles RU) Supervisor modules Without mounting brackets: 7.0 inches (17.78 cm) With mounting brackets: 8.0 inches (20.32 cm) Inside chassis: 20.67 inches (52.5 cm) Ejector levers outside chassis: 0.75 inches (1.9 cm) 1.75 inches (4.4 cm) System Specifications 1 Weights for the Chassis, Modules, Fan Trays, and Power Supplies System Specifications Chassis or Module System controller modules Line cards Fabric modules Fan trays Power supply Width Depth Height Without mounting brackets: 6.81 inches (17.3 cm) With mounting brackets: 7.81 inches (19.84 cm) Inside chassis: 10.74 inches (27.28 cm) Ejector levers outside chassis: 0.75 inches (1.9 cm) 1.42 inches (3.61 cm) 17.0 inches (43.18 cm) Inside chassis: 16.5 inches 1.75 inches (4.4 cm) (41.91 cm) Ejector levers outside chassis: 2.5 inches (6.35 cm) 2.46 inches (6.25 cm) 11.7 inches (29.72 cm) 9.4 inches (23.88 cm) 5.05 inches (12.81 cm) 5.47 inches (13.9 cm) Without mounting brackets: 9.0 inches (22.86 cm) With mounting brackets: 10.6 inches (26.93 cm) 5.25 inches (13.33 cm) Inside chassis: 17.75 inches (44.96 cm) 1.75 inches (4.4 cm) Ejector levers outside chassis: 0.75 inches (1.9 cm) Weights for the Chassis, Modules, Fan Trays, and Power Supplies Component Cisco Nexus 9504 Chassis (N9K-C9504) Supervisor Modules Supervisor A module (N9K-SUP-A) Supervisor A+ module (N9K-SUP-A+) Supervisor B module (N9K-SUP-B) Supervisor B+ module (N9K-SUP-B+) System Controller Module (N9K-SC-A) Line cards that the N9K-C9504-FM fabric modules support Weight per Unit 84.0 lb (38.2 kg) -- 4.84 lb (2.2 kg) 5.2 lb (2.37 kg) 6.0 lb (2.72 kg) 5.3 lb (2.39 kg) 1.9 lb (0.9 kg) -- System Specifications 2 System Specifications Power Specifications Component Weight per Unit 36-port 40-Gigabit Ethernet QSFP+ ACI Spine line card (N9K-X9736PQ) 11.2 lb (5.08 kg) Line cards that the N9K-C9504-FM-E fabric modules support -- 32-port 100-Gigabit Ethernet QSFP28 ACI Spine line card (N9K-X9732C-EX) 12.13 lb (5.5 kg) 36-port 100-Gigabit Ethernet QSFP28 ACI Spine line card (N9K-X9736C-FX) 14.6 lb (6.62 kg) 36-port 40-Gigabit Ethernet QSFP28 ACI Spine line card (N9K-X9736Q-FX) 14.6 lb (6.62 kg) Fabric Modules -- 40-Gigabit N9K-C9504-FM fabric module supporting N9K-X9736PQ line cards 5.76 lb (2.6 kg) 100-Gigabit N9K-C9504-FM-E fabric module 6.6 lb (2.98 kg) Fan Trays -- (N9K-C9504-FAN) 6.4 lb (2.9 kg) (N9K-C9504-FAN2) 7.6 lb (3.45 kg) Power Supplies -- 3-kW AC Power Supply (N9K-PAC-3000W-B) 6.2 lb (2.8 kg) 3-kW Universal AC/DC Power Supply (N9K-PUV-3000W-B) 5.9 lb (2.67 kg) 3.15-kW Dual Input Universal AC/DC Power Supply (N9K-PUV2-3000W-B) 5.9 lb (2.67 kg) 3-kW DC Power Supply (N9K-PDC-3000W-B) 6.4 lb (2.9 kg) Power Specifications Power specifications include the specifications for each type of power supply module. Power Requirements for Switch Modules Determine the number of power supplies required to operate all the modules in a switch by adding the maximum power amounts for each module in the switch. Then divide the sum by 3000 W. If there is a fractional amount in the result, add 1 to the result. For n+1 redundancy, add one more power supply. For n+n redundancy, double the number of power supplies and provision for a second power source. To determine the typical consumption, add the typical power amounts for each module in the switch. Make sure that any new power supplies use the same type of power (AC or DC) as the rest of the power supplies in the switch. Do not use a mix of AC and DC power sources for a switch. Maximum Power Available to the Switch The maximum power available for operations depends on: System Specifications 3 Power Supply Specifications System Specifications · the input power from your power source, · the number and output capabilities of your power supplies, and · the power redundancy mode that you use. The table lists the amount of power available for 3-kW power supplies depending on power inputs, numbers of power supplies, and the mode used. Power Inputs Power Combined Mode Supplies n+1 Redundancy Mode n+n Redundancy Mode 1 input (220 V) 1 2 3 4 3000 W 6000 W 9000 W 12,000 W -- 3000 W 6000 W 9000 W -- 3000 W 3000 W 6000 W Power Supply Specifications These subtopics list the specifications for each power supply that this switch supports. 3000-W AC Power Supply Specifications These specifications apply to the PSU3KW-HVPI power supplies. Property Power Specification 3000 W Input Voltage 200-277 VAC Frequency 50 to 60 Hz Efficiency Redundancy Modes 90% or greater (20 to 100% load) Combined, n+1, and n+n RoHS Compliance Yes Hot Swappable Yes Airflow Direction Port-side intake airflow 3000-W Universal AC/DC Power Supply Specifications Property Power Specification 3000 W Input Voltage 200 to 277 VAC or 240 to 380 VDC or System Specifications 4 System Specifications 3000-W Dual Input Universal AC/DC Power Supply Specifications Property Frequency Efficiency Redundancy Modes RoHS Compliance Hot Swappable Airflow Direction Specification 47 to 63 Hz 90% or greater (20 to 100% load) Combined, n+1, and n+n Yes Yes Port-side intake airflow 3000-W Dual Input Universal AC/DC Power Supply Specifications Property Power Specification 3150 W Input Voltage 180 to 305 VAC or 192 to 400 VDC or Frequency 50 to 60 Hz Efficiency 90% or greater (20 to 100% load) Redundancy Modes Combined, n+1, and n+n RoHS Compliance Yes Hot Swappable Yes Airflow Direction Port-side intake airflow Power Cable Specifications The following subtopics list the specifications for supported power cables. 3-kW AC Power Cable Specifications Locale Argentina Power Cord Part Number CAB-9K16A-ARG Cord Set Rating 16 A, 250 VAC Power Cord Illustration System Specifications 5 System Specifications System Specifications Locale Brazil Power Cord Part Number CAB-9K16A-BRZ Cord Set Rating 16 A, 250 VAC Power Cord Illustration Korea CAB-9K16A-KOR 16 A, 250 VAC South Africa Australia and New Zealand CAB-9K16A-SA CAB-AC-16A-AUS 16 A, 250 VAC 16 A, 250 VAC TBD Peoples Republic of China CAB-AC-16A-CH 16 A, 250 VAC Continental Europe CAB-AC-2500W-EU 16 A, 250 VAC System Specifications 6 System Specifications System Specifications Locale India Power Cord Part Number CAB-C19-C20-IND Cord Set Rating 16 A, 250 VAC Power Cord Illustration India PWR-CORD10-IND 16 A, 250 VAC International CAB-AC-2500W-INT 16 A, 250 VAC Israel CAB-AC-2500W-ISRL 16 A, 250 VAC Japan and North America CAB-AC-2500W-US1 (nonlocking) 200-240 VAC operation 16 A, 250 VAC Japan and North America CAB-AC-C6K-TWLK (locking) 200-240 VAC operation 16 A, 250 VAC System Specifications 7 System Specifications System Specifications Locale Power distribution unit (PDU) Power Cord Part Number CAB-C19-CBN Cord Set Rating 16 A, 250 VAC Power Cord Illustration Switzerland CAB-ACS-16 16 A, 250 VAC Taiwan CAB-AC-C19-TW 16 A, 250 VAC (IEC 60320 C19 to EL 218) US CAB-AC-STRT-C19US 16 A, 250 VAC (straight blade NEMA 6-20 plug) All except Argentina, Brazil, and Japan NO-PWR-CORD No power cord is N.A. included with order. System Specifications 8 System Specifications 3-kW Universal AC/DC and 3-kW Dual Input Universal AC/DC Power Cable Specifications 3-kW Universal AC/DC and 3-kW Dual Input Universal AC/DC Power Cable Specifications Locale Power Cord Part Number Cord Set Rating Power Cord Illustration Australia and New CAB-AC-16A-SG-AZ Zealand 16 A, 250 VAC (AU20LS3/Saf-D-Grid) CAB-AC-16A-SG-EU 16A, 250 VAC Israel CAB-AC-16A-SG-IS 16 A, 250 VAC System Specifications 9 System Specifications System Specifications Locale International/UK Power Cord Part Number CAB-AC-16A-SG-IN Cord Set Rating 16 A, 250 VAC Power Cord Illustration Italy CAB-AC-16A-SG-IT 16 A, 250 VAC South Africa CAB-AC-16A-SG-SA 16 A, 250 VAC System Specifications 10 System Specifications System Specifications Locale Switzerland Power Cord Part Number CAB-AC-16A-SG-SW Cord Set Rating 16 A, 250 VAC Power Cord Illustration North America CAB-AC-20A-SG-C20 250 VAC 20 A North America CAB-AC-20A-SG-US 16 A, 250 VAC North America (non CAB-AC-20A-SG-US2 locking) 200-240 VAC operation 250 VAC 20 A North America CAB-AC-20A-SG-US3 250 VAC 20 A System Specifications 11 System Specifications System Specifications Locale Power Cord Part Number North America 277 CAB-AC-20A-SG-US4 VAC operation Cord Set Rating 277 VAC 20 A Power Cord Illustration International, CAB-HV-25A-SG-IN1 Saf-D-Grid/Saf-D-Grid 400 VAC 20 A International, Ring CAB-HV-25A-SG-IN2 Terminal source plug, Ring Terminal/Saf-D-Grid 20A, 300 VAC/500 VDC North America CAB-HV-25A-SG-US1 277 VAC/ 240 VDC/ 380 VDC 25 A System Specifications 12 System Specifications 3-kW DC Power Supply Power Cord Specifications Locale North America Power Cord Part Number CAB-HV-25A-SG-US2 Cord Set Rating 277 VAC/ 240 VDC/ 380 VDC 25 A Power Cord Illustration All except Argentina, NO-PWR-CORD Brazil, and Japan No power cord N.A. included with order 3-kW DC Power Supply Power Cord Specifications Each 3-kW DC power supply requires four customer-supplied power cables (two negative cables and two positive cables). We recommend using six gauge cables. Cisco supplies 6-gauge lugs for connections to the power supply. You supply the connectors that are required to connect the cables to the DC power source. System Specifications 13 3-kW DC Power Supply Power Cord Specifications System Specifications System Specifications 14DITA Open Toolkit XEP 4.30.961; modified using iText 2.1.7 by 1T3XT