User Guide for E plus E models including: EE600 Differential Pressure Sensor, EE600, Differential Pressure Sensor, Pressure Sensor, Sensor
Nyomáskülönbség távadók | HVAC | Sensortech-Pro
File Info : application/pdf, 1 Pages, 523.26KB
DocumentDocumentQuick Guide EE600 - Differential Pressure Sensor PLEASE NOTE Find this document and further product information on our website at www.epluse.com/ee600. Electrical Connection WARNING Incorrect installation, wiring or power supply may cause overheating and therefore personal injuries or damage to property. It is essential that the cables are not under voltage during installation. No voltage must be applied when the product is connected or disconnected. For correct cabling of the device, always observe the presented wiring diagram for the product version used. The manufacturer cannot be held responsible for personal injuries or damage to property as a result of incorrect handling, installation, wiring, power supply and maintenance of the device. Analogue Output P1o5w-e3r5sVupDpCly 15 - 35 V DC OUT1 Installation Pressure Connection Mounting Examples Use a Ø7.5 mm drill for installing the pressure connection nipples into the duct. User Interface - LED Indication Green LED Flashing (1 s interval) EE600 operates normally, the measured data is within the selected measuring range One flash (2 s) Confirms adjustment or return to factory settings Off No power supply or electronics failure Fast flashing Auto-zero is executed (0.2 s interval) (first time 90 min after start / reset) Red LED Flashing (1 s interval) One flash (2 s) The measured data is out of the selected range (overload or reversed pressure connection) Indicates the failure of the attempt to adjust zero point or span point, or to return to factory adjustment EE600 with 2-wire Analogue Output S1 S2 MR1) S3 S4 Time S5 S6 Unit 0 0 100 % 0 0 50 ms 0 0 Pa 1 0 75 % 1 0 500 ms 1 0 mbar S72) S8 -0 -1 Auto-zero3) On Off S9 Setting4) S10 0 DIP switches 0 1 PCS10 1 MD5) Bidirectional Unidirectional 0 1 50 % 0 1 2 s 0 1 inch WC 1 1 25 % 1 1 4 s 1 1 kPa 1) Measuring range 2) No function 3) Auto-zero version only 4) These and further settings can be changed with PCS10 via USB configuration adapter (HA011066) while DIP switch S9 = 1 5) Measuring direction Measuring range examples: S1 = 1, S2 = 0, S9 = 0, S10 = 1 S1 = 0, S2 = 0, S9 = 0, S10 = 0 0...750 Pa or 0...7 500 Pa ±1 000 Pa or ±10 000 Pa or customised measuring range PLEASE NOTE With the 2-wire version, manual zero point adjustment is only possible every 90 minutes if an auto-zero valve is present. E+E Elektronik Ges.m.b.H. Langwiesen 7 4209 Engerwitzdorf | Austria T +43 7235 605-0 F +43 7235 605-8 info@epluse.com www.epluse.com QG_EE600_bidirectional | Version v1.0 | 10-2024 | All rights reserved | 350212