REGISTERED DESIGN • REGISTERED PATENT
Thank you for purchasing this Airflow Ceiling Sweep Fan. You can be assured of trouble-free operation by installing your ceiling fan carefully and according to these instructions. Please read all the instructions before commencing, then complete each step in order.
DANGER
HAZARD OF ELECTRIC SHOCK OR ARC FLASH
- This equipment must only be installed and serviced by appropriate qualified and/or licenced electrical personnel.
- Isolate the electrical supply before doing any work on this equipment.
- Ensure that the product had been correctly installed and tested before reconnecting the electrical supply.
Failure to follow these instructions will result in death or serious injury.
NOTICE
HAZARD OF INCORRECT ASSEMBLY
- To ensure proper balance, do not mix up blades with those from another fan as they are a matched set.
- Transport and transit handling may loosen factory fitted cables. Please check and secure terminal screws before installation.
Failure to follow these instructions can result in equipment damage.
NOTICE
HAZARD OF PRODUCT DAMAGE
- Do not place the motor directly onto a flat surface. The plastic nipple underneath the motor cannot support the weight of the motor and may be easily damaged.
- When working on the fan, place the motor on the foam packaging with the nipple located in one of the recesses. This protects the nipple and the finish.
Failure to follow these instructions can result in equipment damage.
Included with your Fan
- A. Motor Assembly
- B. Four Blades
- C. Three-Speed Fan Controller
- D. Screw Pack
- E. Mounting Bracket
- F. Instruction Sheet
Visual description of included parts: A shows the motor housing. B shows four fan blades. C shows a rotary speed controller. D shows a pack of screws. E shows a mounting bracket. F shows the instruction sheet.
Controlling a Single Fan
This fan has been supplied with a Clipsal Three-Speed Controller that is designed to operate a single fan. The controller has settings OFF, 1 (low), 2 (medium), and 3 (high).
Multiple Fans on a Single Controller
Where multiple fans are required to be operated from a single controller, a Clipsal C-Thru™ Electronic Fan Controller (purchased separately) must be used.
NOTICE
HAZARD OF INCORRECT USAGE
The three-speed fan controller supplied with each fan is not suitable for controlling multiple fans.
Failure to follow these instructions can result in equipment damage.
1.0 Mounting the Fan Support Bracket
WARNING
LOCATION HAZARD
- Select a suitable location to mount the fan support bracket.
- The mounting bracket must be fixed to a solid structural member, such as a ceiling joist or a securely fixed noggin, and be capable of supporting 15 kg.
- Additionally, it is recommended to provide the blade with a minimum clearance from the floor of 2.1m, and from other obstructions of at least 300mm.
Failure to follow these instructions can result in injury or equipment damage.
Diagram description: Shows secure fixing to support 15kg for both Hangsure Mounting and J-Hook Mounting.
Clearances and Angled Ceilings
Blades: Minimum 2.1m above floor.
Clearance: Minimum 300mm from other obstacles.
Hangsure Mounting is suitable for pitched ceilings with a maximum angle of 18.5°.
2.0 Fitting the Blades
Place the blade over the motor and align screws. Securely tighten both screws.
Diagram description: Shows four steps (A, B, C, D) for fitting blades. Step A shows foam packaging and supporting the motor. Step B shows motor screw holes. Step C shows sliding the blade over screws. Step D shows tightening screws.
3.0 Connecting the Light Fitting
If you are attaching a light fitting to the fan, do so prior to hanging the fan.
NOTE: Clipper Light or Oyster Light may be installed in fans that are constructed for this purpose.
- Unscrew the plastic nipple from the bottom of the motor housing.
- Pull out the light wires from the motor housing for connection with the lamp holder.
- Insert the light wires through the adaptor, then screw the adaptor into the motor shaft.
- Connect the light wires to the lamp holder then screw the lamp holder and the adaptor together firmly.
Diagram description: Shows light wires, plastic nipple, adaptor, and lamp holder connection.
4.0 Hanging the Fan
Hangsure Bracket
Position the ball-joint in the bracket so that the guide pin on the bracket engages in the slot in the ball-joint.
J-Hook Bracket
Fit the rubber wheel assembly over mounting.
Diagram description: Shows a ceiling, cowling, and screw. A 5-10mm gap is indicated between the ceiling and cowling.
NOTICE
HAZARD OF CEILING DAMAGE
For j-hook brackets, leave a 5-10mm gap between the ceiling and cowling. It's normal for the cowling to move slightly when the fan is running. This gap prevents damaging the painted ceiling and prevents ticking or clicking noises.
Failure to follow these instructions can result in equipment damage.
5.0 Connecting the Fan
All Airflow Ceiling Sweep Fans are pre-wired to allow for a light to be fitted onto the fan. If you are not fitting a light to the fan, please disregard the light wires. The wires are connected to the incoming wiring as illustrated in the diagram.
Means for all pole disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
Wiring Colors:
- BROWN: SWITCHED ACTIVE (Fan)
- BLUE: NEUTRAL
- RED: SWITCHED ACTIVE (Optional Light)
- GREEN: EARTH
Diagram description: Shows a fan with light wiring connections: Brown to Switched Active (Fan), Blue to Neutral, Red to Switched Active (Optional Light), Green to Earth.
6.0 Connecting the Speed Controller (Fan Only)
All Airflow Ceiling Sweep Fans come complete with a three-speed flush fitting capacitor controller. This controller fits to standard 84mm fixing centres, the same as a normal switch or power point. Although supplied standard in the vertical format, the mechanism can be rotated 90° to provide a horizontal format if required.
To ensure that the "off" position of the switch is at the top when installed, the mechanism must be installed into the plate with the three screw heads pointing upwards. The mechanism must be fully "clipped" into the plate from the rear. Three is the highest speed, one is the lowest.
- Remove switch surround.
- Terminate cables as illustrated in the diagram.
- Active to common and switched active to terminal one.
- Fix controller to wallbox or bracket using screws provided. Screws may need to be shortened for some applications.
- Replace switch surround.
Diagram description: Shows a rotary switch mechanism with terminals COM, 1, 2, 3. It also shows a capacitor. The diagram illustrates connections for 'ACTIVE' and 'SWITCHED ACTIVE (TO FAN MOTOR)' to COM and terminals respectively.
7.0 Connecting the Speed Controller with a Light Switch
Connecting the speed controller with a light switch requires additional components (not supplied with this fan) including: Clipsal 30M Switch Mechanism, Two gang grid plate and cover.
Diagram description: Shows a Clipsal 30M Switch Mechanism and a Rotary Switch Mechanism connected, with terminals labeled COM, L, 1, 2, 3. It illustrates wiring for a fan with a light switch.
8.0 Operating Instructions
- Turn the knob to speed three (top position). This will start the blades spinning.
- Once the blades are spinning you can select a lower speed if desired.
- The speed setting is always located at the top position of the knob as illustrated below.
Diagram description: Shows the operating knob with positions labeled OFF, 1, 2, 3, with 'Top Position' indicated.
Summer/Winter Settings
The forward/reversible switch is located on the bottom cowl.
SUMMER: Push switch up ⬆️ for the blades to create a breeze and circulate the air.
WINTER: Push switch down ⬇️ for the blades to circulate the warm air trapped near the ceiling.
NOTE: The forward/reversible switch must be fully engaged for the fan to operate.
Cleaning Instructions
To clean the fan, wipe over with a damp, soapy cloth. Do not use scourers or abrasive cleaners.
Troubleshooting Guide
Fan will not switch on.
- Switch off the fan. Then check the following:
- Forward/reverse switch on fan motor not fully engaged in desired setting.
- Connections not as per installation diagram.
- Fuse blown, circuit breaker tripped, or there is a power failure.
Fan will not operate at varying speed control settings.
- Controller connections not as per page 3.
Ticking, rattling, mechanical noises.
- Ensure all screws and bolts are tight.
- Ensure the mounting assembly is secure.
- Ensure the lower canopy is clear of the motor.
- With hook mount models, ensure the top canopy is clear of the ceiling by 5 to 10mm to allow for slight movement of the fan.
- Ensure the wires are not tapping against the canopy.
CAUTION
MOVING PARTS OR ELECTRICAL HAZARD
- Do not attempt to stop the blades by hand, even at low speed.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
- Ensure all electrical supplies are disconnected before cleaning, maintenance and attachment of lamp kit.
Failure to follow these instructions can result in injury or equipment damage.
Warranty
The benefits conferred by this warranty are in addition to all implied warranties, other rights and remedies in respect of the product which the consumer has under the Trade Practices Act and similar State and Territory Laws.
The original purchaser of this Airflow Ceiling Sweep Fan is provided with the following warranty, subject to the following conditions:
Schneider (Australia) Pty Ltd warrants this product for a period of three years from the date of purchase for all parts defective in workmanship or materials. All products used in commercial applications are limited to a 90-day warranty.
All defective parts will be replaced free of charge. The following exclusions do not preclude the purchaser from those statutory rights consumers have under the Trade Practices Act or similar State and Territory Laws.
WARRANTY CONDITIONS:
- This warranty is only valid for appliances installed according to the manufacturer's instructions.
- This appliance must not be modified or changed in any way and all electrical connections must be carried out by a qualified electrician only.
- Connection must be to the voltage requirements as specified in the ratings label located on the product.
- The manufacturer does not accept liability for any direct or consequential damage, loss or other expense arising from misuse or incorrect installation and operation of the appliance.
- Warranty will only be given where proof of purchase is provided, e.g. original invoice.
- For warranty to be valid, only Airflow accessories, such as down rods and light kits, shall be installed with the Airflow Ceiling Sweep Fan.
IMPORTANT
Record this warranty information at the time of purchase but do not send this information unless you are making a claim or are asked to do so.
To obtain service under warranty you must retain your original purchase receipt; service will otherwise be charged at current rates.
Record Keeping:
- Model No.:
- Purchase from:
- Name:
- Address:
- Date of purchase: Postcode:
Technical Support
For further technical support contact the Clipsal National Customer Service Centre on 1300 2025 25.
Schneider Electric (Australia) Pty Ltd
Contact us: clipsal.com/feedback
National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56