Victron Orion-Tr Smart DC-DC Charger Isolated
250/400 Watt | With 3-stage battery charge algorithm
Visit: www.victronenergy.com
Key Features
- Bluetooth Smart Enabled: Monitor, change settings, and update firmware via the VictronConnect App on smartphones or tablets. Instant readout of data, warnings, and alarms.
- Fully Programmable: Supports configurable battery charge algorithms or fixed output voltage.
- Smart Alternator Compatibility: Features engine running detection to prevent starter battery discharge when the engine is off (Euro 5/6 engines).
- Adaptive 3-Stage Charge Algorithm: Bulk, Absorption, Float stages optimized for lead-acid and lithium batteries. Absorption time adjusts based on discharge depth for lead-acid; fixed for lithium.
- Remote On/Off: Connect a switch or relay to a two-pole connector for remote control.
- Parallel Capability: Multiple units can be connected in parallel to increase output current.
- High Temperature Protection: Output current reduces at high ambient temperatures.
- IP43 Protection: Achieved when installed with screw terminals oriented downwards.
- Screw Terminals: Facilitates installation without special tools.
- Input Fuse: Non-replaceable.
Diagram Description
A diagram illustrates the charger's connection: An alternator connects to the input/starter battery, and the Orion-Tr Smart DC-DC charger connects between the starter battery and the output/auxiliary battery. The VictronConnect app interface is shown on a smartphone, displaying charger status like input voltage, output voltage, and charge mode (e.g., Bulk).
Model Specifications
Orion-Tr Smart Chargers Isolated 220 - 280 Watt
| Specification | 12/12-18 (220 W) | 12/24-10 (240 W) | 24/12-20 (240 W) | 24/24-12 (280 W) |
|---|---|---|---|---|
| Input voltage range (1) | 8-17 V | 8-17 V | 16-35 V | 16-35 V |
| Under voltage shut down | 7 V | 7 V | 14 V | 14 V |
| Under voltage restart | 7.5 V | 7.5 V | 15 V | 15 V |
| Nominal output voltage | 12.2 V | 24.2 V | 12.2 V | 24.2 V |
| Output voltage adjust range | 10-15 V | 20-30 V | 10-15 V | 20-30 V |
| Output voltage tolerance | +/- 0.2 V | +/- 0.2 V | +/- 0.2 V | +/- 0.2 V |
| Output noise | 2 mV rms | 2 mV rms | 2 mV rms | 2 mV rms |
| Cont. output current at nominal output voltage and 40 °C | 18 A | 10 A | 20 A | 12 A |
| Maximum output current (10 s) at nominal output voltage minus 20 % | 25 A | 15 A | 25 A | 15 A |
| Short circuit output current | 40 A | 25 A | 50 A | 30 A |
| Cont. output power at 25 °C | 280 W | 280 W | 300 W | 320 W |
| Cont. output power at 40 °C | 220 W | 240 W | 240 W | 280 W |
| Efficiency | 87 % | 88 % | 88 % | 89 % |
| No load input current | < 80 mA | < 100 mA | < 100 mA | < 80 mA |
| Standby current | Less than 1mA | Less than 1mA | Less than 1mA | Less than 1mA |
| Galvanic isolation | 200 VDC between input, output and case | |||
| Operating temperature range | -20 to +55 °C (derate 3% per °C above 40 °C) | |||
| Humidity | Max. 95% non-condensing | |||
| DC connection | Screw terminals | |||
| Maximum cable cross-section | 16 mm² AWG6 | |||
| Weight | 1.3 kg (3 lb) | 1.3 kg (3 lb) | 1.3 kg (3 lb) | 1.3 kg (3 lb) |
| Dimensions h x w x d | 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch) | |||
| Protection category | IP43 (electronic components), IP22 (connection area) | |||
| Standards: Safety | EN 60950 | |||
| Emission / Immunity | EN 61000-6-3, EN 55014-1 / EN 61000-6-2, EN 61000-6-1, EN 55014-2 | |||
| Automotive Directive | ECE R10-5 | |||
Orion-Tr Smart Chargers Isolated 360 - 400 Watt
| Specification | 12/12-30 (360 W) | 12/24-15 (360 W) | 24/12-30 (360 W) | 24/24-17 (400 W) |
|---|---|---|---|---|
| Input voltage range (1) | 10-17 V | 10-17 V | 20-35 V | 20-35 V |
| Under voltage shut down | 7 V | 7 V | 14 V | 14 V |
| Under voltage restart | 7.5 V | 7.5 V | 15 V | 15 V |
| Nominal output voltage | 12.2 V | 24.2 V | 12.2 V | 24.2 V |
| Output voltage adjust range | 10-15 V | 20-30 V | 10-15 V | 20-30 V |
| Output voltage tolerance | +/- 0.2 V | +/- 0.2 V | +/- 0.2 V | +/- 0.2 V |
| Output noise | 2 mV rms | 2 mV rms | 2 mV rms | 2 mV rms |
| Cont. output current at nominal output voltage and 40 °C | 30 A | 15 A | 30 A | 17 A |
| Maximum output current (10 s) at nominal output voltage minus 20 % | 40 A | 25 A | 45 A | 25 A |
| Short circuit output current | 60 A | 40 A | 60 A | 40 A |
| Cont. output power at 25 °C | 430 W | 430 W | 430 W | 480 W |
| Cont. output power at 40 °C | 360 W | 360 W | 360 W | 400 W |
| Efficiency | 87 % | 88 % | 88 % | 89 % |
| No load input current | < 80 mA | < 100 mA | < 100 mA | < 80 mA |
| Standby current | Less than 1mA | Less than 1mA | Less than 1mA | Less than 1mA |
| Galvanic isolation | 200 VDC between input, output and case | |||
| Operating temperature range | -20 to +55 °C (derate 3% per °C above 40 °C) | |||
| Humidity | Max. 95% non-condensing | |||
| DC connection | Screw terminals | |||
| Maximum cable cross-section | 16 mm² (AWG6) | |||
| Weight | 12 V input and/or 12 V output models: 1.8 kg (3 lb) | Other models: 1.6 kg (3.5 lb) | 12 V input and/or 12 V output models: 1.8 kg (3 lb) | Other models: 1.6 kg (3.5 lb) |
| Dimensions h x w x d | 12 V input and/or 12 V output models: 130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch) | Other models: 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch) | 12 V input and/or 12 V output models: 130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch) | Other models: 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch) |
| Protection category | IP43 (electronic components), IP22 (connection area) | |||
| Standards: Safety | EN 60950 | |||
| Emission / Immunity | EN 61000-6-3, EN 55014-1 / EN 61000-6-2, EN 61000-6-1, EN 55014-2 | |||
| Automotive Directive | ECE R10-5 | |||
Note 1: If the output voltage is set to nominal or lower, it remains stable within the specified input voltage range (buck-boost function). If set higher, the minimum input voltage for stability increases proportionally.
Note 2: The VictronConnect App does not display input or output current. The Orion-Tr Smart does not have a VE.Direct port.