FEATURES. • MEETS OR EXCEEDS ASHRAE 90.1-2013 / MEETS EPACT 2010. EFFICIENCY*. • SMART EQUIPMENT™ W/COMMUNICATION BACNET MS/TP.
SUBMITTAL DATA SHEET SPLIT-SYSTEM AIR CONDITIONING CONDENSING UNITS 7.5 - 25 TONS MODELS: YC090 through 300 and YE090, 2-PIPE YD120 through 240, 4-PIPE JOB NAME: PURCHASER: ENGINEER: SUBMITTED TO: SUBMITTED BY: UNIT DESIGNATION: FOR: REF: LOCATION: ORDER NO: APPROVAL: DATE: SCHEDULE NO. CONSTRUCTION: MODEL NO. _ COOLING PERFORMANCE TOTAL CAPACITY- - - - - - - - - - - - - - _____ MBH OUTDOOR DESIGN TMP. - - - - - - - - - - _____ °F SUCTION PRESSURE AT SATURATION - - - - - - - - - - - - - - - - - _____ PSIG SUCTION TEMPERATURE AT SATURATION - - - - - - - - - - - - - - - - - - - _____ °F ELECTRICAL DATA POWER SUPPLY - - - - - - - - - _____/_____/_____ TOTAL UNIT AMPACITY - - - - - - - - _____ AMPS POWER INPUT REQ. - - - - - - - - - - - - - _____ KW MINIMUM WIRE SIZE - - - - - - - - - - - - _____ AWG (COPPER CONDUCTORS) MAXIMUM FUSE SIZE - - - - - - - - - - _____ AMPS (DUAL ELEMENT) UNIT WEIGHT TOTAL OPERATING WEIGHT - - - - - _____ LBS FEATURES · MEETS OR EXCEEDS ASHRAE 90.1-2013 / MEETS EPACT 2010 EFFICIENCY* · SMART EQUIPMENTTM W/COMMUNICATION BACNET MS/TP (PROGRAMMABLE TO MODBUS OR N2 PROTOCOLS) · R-410A REFRIGERANT · POWDER PAINT FOR DURABILITY · WEATHERIZED CASING FOR OUTDOOR USE · PROPELLER-TYPE CONDENSER FANS · INHERENTLY PROTECTED FAN MOTORS · HIGH AND LOW PRESSURE SAFETIES · SCROLL COMPRESSORS · CRANKCASE HEATERS · ALUMINUM TUBE/ALUMINUM FIN "MICROCHANNEL" COILS · BACKSEATING SUCTION AND LIQUID LINE SERVICE VALVES · SINGLE AND DUAL REFRIGERATION CIRCUITS (SINGLE ON YC AND DUAL ON YD MODELS) · LOW AMBIENT TO 40°F - LOW AMBIENT AVAILABLE TO 0°F · PROVISIONS FOR HOT GAS BYPASS · CSA APPROVAL · ONE YEAR LIMITED PARTS WARRANTY ON COMPLETE UNIT · FIVE YEAR LIMITED COMPRESSOR WARRANTY · LIQUID LINE DRIERS (SUPPLIED FOR FIELD INSTALLATION) · FACTORY INSTALLED DISCONNECT OPTION · FACTORY INSTALLED POWERED OR NON-POWERED 120V OUT- LET OPTION · FULL PERIMETER BASE RAIL-FORK TRUCK ACCESSIBLE · CRANE RIGGING PROVISIONS *WHEN COUPLED WITH MATCHING INDOOR UNIT YC090, YE090, YC120, YD120, YC150, YD150 Johnson Controls Ducted Systems YC180, YD180, YC240, YD240, YC300 506413-YSD-J-0419 506413-YSD-J-0419 WEIGHT DISTRIBUTION CORNER WEIGHTS & CENTER OF GRAVITY Size (Tons) 090 (7.5) 120 (10) 150 (12.5) 180 (15) 240 (20) 300 (25) Model YC090 YE090 YC120 YD120 YC150 YD150 YC180 YD180 YC240 YD240 YC300 Weight (lbs.) Shipping Operating 390 387 386 383 499 497 493 490 499 497 493 490 914 909 899 894 945 942 930 927 945 942 Center of Gravity (in.) X Y 17 32.3 18 33.5 17.3 32.3 17.4 32.5 17 32.3 17.4 32.5 32.5 31.5 32.5 31.5 30.3 31.0 32.7 31.8 30.3 31.0 4 Point Load Location (lbs.) A B C D 99 113 94 82 95.0 124.3 92.8 70.9 124 147 122 103 123 147 120 100 127 145 120 105 123 147 120 100 239 246 215 209 235 242 212 206 261 234 212 236 244 255 218 210 261 234 212 236 LEFT D DIM X CG FRONT WIDTH C DIM Y LENGTH RIGHT YC090, YE090, YC120, YD120, YC150, YD150 D A DIM X REAR FRONT B WIDTH LEFT CG C DIM Y LENGTH RIGHT YC180, YD180, YC240, YD240, YC300 A REAR B 2 Johnson Controls Ducted Systems 31.90 UNIT DIMENSIONS YC090, YE090, YC/YD120, YC/YD150 RIGHT REAR LEFT 59.10 506413-YSD-J-0419 FRONT 1.33 2.097 BASE RAIL DETAIL 2.375 TOP BOTTOM 2.923 3.563 3.43 3.75 7.000 10.000 24.000 31.758 FRONT 7.000 CONVENIENCE OUTLET A 2X (Ø 1.375) 30.994 KNOCKOUT 12.126 9.876 4.751 3.883 3.664 2.933 1.664 SYSTEM 2 2X (Ø 0.875) KNOCKOUT 7.000 23.000 37.000 58.500 RIGHT 7.000 SYSTEM 1 15.53 12.70 REAR 6.26 7.52 8.98 10.60 2X (Ø 1.375) KNOCKOUT LEFT 2X (Ø 0.875) KNOCKOUT 12.000 10.000 4.875 4.132 2.382 1.882 *See UNIT HEIGHT DIMENSIONS, PIPING AND ELECTRICAL CONNECTIONS SIZES (next page) Johnson Controls Ducted Systems 3 506413-YSD-J-0419 UNIT HEIGHT DIMENSIONS (INCHES) MODEL A YC090 44.5 YE090 44.5 YC120 50.0 YD120 50.0 YC150 50.0 YD150 50.0 PIPING AND ELECTRICAL CONNECTIONS SIZES (INCHES) MODEL YC090 YE090 YC120 YD120 YC150 YD150 No. refrigeration circuits 1 1 1 2 1 2 Suction line OD (in.) 1 1/8 1 1/8 1 3/8 1 1/8 1 3/8 1 1/8 Liquid line OD (in.) 5/8 5/8 7/8 5/8 7/8 5/8 Power wiring knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 Control wiring knockout 7/8 7/8 7/8 7/8 7/8 7/8 4 Johnson Controls Ducted Systems UNIT DIMENSIONS YC/YD180, YC/YD240 & YC300 REAR 506413-YSD-J-0419 LEFT RIGHT 59.10 FRONT 64.10 1.33 2.097 BASE RAIL DETAIL 2.375 TOP SYSTEM 2 SYSTEM 1 BOTTOM 2.923 3.563 3.43 3.75 7.000 23.000 37.000 64.000 FRONT 7.000 A 30.994 11.375 9.125 4.750 4.132 3.913 3.181 1.913 2X (Ø 1.375) KNOCKOUT 2X (Ø 0.875) KNOCKOUT 7.000 23.000 37.000 59.000 RIGHT 7.000 SYSTEM 2 SYSTEM 1 16.133 13.133 17.367 18.867 20.617 22.617 FRONT (PIPING DETAIL) *See UNIT HEIGHT DIMENSIONS, PIPING AND ELECTRICAL CONNECTIONS SIZES (next page) Johnson Controls Ducted Systems 5 UNIT HEIGHT DIMENSIONS (INCHES) MODEL A YC180 44.5 YD180 44.5 YC240 50.0 YD240 50.0 YC300 50.0 PIPING AND ELECTRICAL CONNECTIONS SIZES (INCHES) MODEL YC180 YD180 YC240 YD240 YC300 No. Refrigeration Circuits 1 2 1 2 1 Suction Line OD (in.) 1 5/8 1 1/8 1 5/8 1 3/8 2 1/8 Liquid Line OD (in.) 7/8 5/8 7/8 5/8 7/8 Power Wiring Knockout 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 Control Wiring Knockout 7/8 7/8 7/8 7/8 7/8 MINIMUM CLEARANCES CLEARANCE DESCRIPTION DISTANCE IN INCHES Overhead (Top) 120 Front 36 Rear 24 Left Side 30 Right Side 30 Bottom1 0 1. In all installations where snow accumulates and winter operation is expected, additional height must be provided to insure normal condenser airflow. FACTORY-INSTALLED OPTIONS DISCONNECT - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - NON-POWERED CONV. OUTLET - - - - - - - - - - - - - - - - POWERED CONV. OUTLET - - - - - - - - - - - - - - - - - - - - PHASE MONITOR - - - - - - - - - - - - - - - - - - - - - - - - - - - COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - LOW AMBIENT TO 0° - - - - - - - - - - - - - - - - - - - - - - - - - TECHNICOATED COIL - - - - - - - - - - - - - - - - - - - - - - - - E-COAT COIL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FIELD-INSTALLED ACCESSORIES COIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HAIL GUARD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - LOW AMBIENT KIT - - - - - - - - - - - - - - - - - - - - - - - - - - - HOT GAS BYPASS KIT- - - - - - - - - - - - - - - - - - - - - - - - MATCHING AIR SIDE EQUIPMENT DATA MODEL NUMBER _______________________________ SUBMITTAL FORM NUMBER ______________________ REFER TO UNIT TECHNICAL GUIDE FOR THE LIST OF STANDARD FEATURES ATTACHED NOT ATTACHED NOTES: ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ ____________________________________________________________________________________________________ Subject to change without notice. Printed in U.S.A. Copyright © 2019 by Johnson Controls, Inc. All rights reserved. York International Corporation 5005 York Drive Norman, OK 73069 506413-YSD-J-0419 Supersedes: 506413-YSD-I-0218FrameMaker 2017 Acrobat Distiller 11.0 (Windows)