User Guide for ZKTeco models including: ProFace X DS, ProFace X, ProFace DS, ProFace

ProFaceX (DS) Quick Start Guide V1.0-20220308

Download

ZKTeco Malaysia

ProFaceX (DS) Quick Start Guide V1.0-20220308

ProFaceX (DS) Quick Start Guide

Index of /wp-content/uploads/download-manager-files/


File Info : application/pdf, 17 Pages, 39.90MB

PDF preview unavailable. Download the PDF instead.

ProFaceX (DS) Quick Start Guide
Quick Start Guide
ProFace X (DS)
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.

1Overview

Near-infrared Flash
Microphone Camera 8-inch Touchscreen Under-screen Card Reading Area
Tamper Switch

Speaker Reset Button

RS232 RS485

12V 12V GND GND GND RXD1 TXD1 485B 485A GND 12V

Wiegand Out Wiegand In

WD1 WD0 INWD1 INWD0 GND 12V

Power interface

+12V GND GND AUX GND SEN GND BUT NO COM NC ALAL+

Power Auxiliary input Sensor Exit button Lock
Alarm

Networkinterface

Note: Not all products have the function with , the real product shall prevail. 1

2 Installation Environment
Please refer to the following recommendations for installation.

6.5ft 10ft
KEEP DISTANCE

window

AVOID GLASS REFRACTION

3 Device Installation

AVOID DIRECT SUNLIGHT
AND EXPOSURE

KEEP EFFECTIVE DISTANCE 0.3-2.5m

Install on the wall
Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
Fix the backplate on the wall using wall mounting screws. Attach the device to the backplate. Fasten the device to the backplate with a security screw.

1

2

1.5m

3

4



 2

3 Device Installation
Install on the barrier gate
Please thread the wire through the bracket before installation. Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut. Adjust the angle of the device.
1

 2
30mm 3

4 Standalone Installation
Alarm

Door Sensor

Reader

Lock

DSemteockteor

Exit Button

TCP/IP

PC

5 Door Sensor, Exit Button & Alarm Connection

Detector Power

+

COM GND

NO AUX

SmokeDetector GND SEN

GND BUT

Door Sensor

ExitButton

NO COM

Alarm

NC

-

+

AL-

AL+

-

+

Alarm Power

4

6 Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally unlocked when power-on) is connected with 'NO' and 'COM' terminals, and the NC LOCK (normally locked when power-on) is connected with 'NC' and 'COM' terminals. Take NC Lock as an example below:
1)Device not sharing power with the lock2)Devicesh aring power with the lock

DC12V

GND +12V

DC12V

+12V GND

Maximum 30V 3A input. DC12V
FR107
Normally Closed Lock

GND AUX GND SEN GND BUT NO COM NC ALAL+

FR107
Normally Closed Lock

GND AUX GND SEN GND BUT NO COM NC ALAL+

7 Wiegand Reader Connection

WD1 WD0 INWD1 INWD0 GND 12V
5

Access controller
GND +12V
Wiegand reader

8 Barrier Connection
12V 12V GND GND GND RXD1 TXD1 485B 485A GND 12V

Barrier gate

9 RS485 Connection

12V 12V GND GND GND RXD1 TXD1 485B 485A GND 12V

+12V GND 485485+ GND
485 reader

Note: 485A and 485B can be connected to the Barrier gate or the 485 Reader, separately, but cannot be connected to the gate and reader at the same time.

6

10 Power Connection

12V3ADC

Recommended power supply: 12V - 3A To share the power with other devices, use a power supply with higher current ratings.
11 Ethernet Connection
Connect the device and computer software over an Ethernet cable. An example is shown below:
ZKBioSecurity

Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0

IP address: 192.168.1.130 Subnet mask: 255.255.255.0

Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to ZKBioSecurity software.
Click on [Comm.] > [Ethernet] > [IP Address], input the IP address and click on [OK].

7

12 UserRegistration
When there is no super administrator set in the device, click on to enter the menu. After setting the super administrator, the system will request for the administrator's verification before entering the menu. For the security purpose, it is recommended to register a super administrator at the first time you use the device.
Method1: Register on the device Clickon> [User Mgt.] > [New User] to register a new user. Settings include entering user ID and name, face, card, password and profile photo, setting user role and access control role.

Main Menu

L User Mgt. User Role

COMM.

System

Personalize

Data Mgt. Access Control Attendance Search

New User

User Mgt.

All Users

Display Style

Print

Autotest System Info

L

User ID Name

New User

User Role

Face

Card Number Password Profile Photo Access Control Role

1 Mike Normal User
**********

Enroll Card Number Card Number:1311129048

Enroll Face

8

Method2: Register on ZKBioSecurity software
Please set the IP address and cloud service server address in the Comm. Menu option on the device.
1. Click [Access] > [Access Device] > [Device] > [Search Device] to search the device on the software. When an appropriate server address and port is set on the device, the searched devices are displayed automatically.

Refresh

New

Delete

Export

Search Device

Device Control

Set up

Search Total Progress
IP Address

Step 1

Search Device

No device found? Download Search Tools to Local Disk

Step 2

Searched devices count:2 Number of devices added:1

Device Type

Serial Number

IP Address 192.168.0.31 192.168.10.214

MAC Address

Subnet Mask Gateway Address Serial Number Device Type

255.255.255.0 192.168.0.1

XXXX000000000 S***********

255.255.255.0 192.168.1.1

XXXX000000000 ProFace X (DS)

View and Get Device Info

Communication

Set Server

Operations
Step 3 This device has been added
Add

Add

Device Name*

192.168.4.18

Icon Type*

Door

Area*

Area Name

Add to Level

Clear Data in the Device when Adding
The current systen communication port is 8088, please make sure the device is set correctly. [Clear Data in the Device when Adding] will delete data in the device (except event record), please use with caution!

Step 4

OK

Cancel

2. Click [Add] in operation column, a new window will pop-up. Select Icon type, Area, and Add to Level from each dropdowns and click [OK] to add the device.
3. Click [Personnel] > [Person] > [New] and fill in all the required fields to register a new users in the software.
4. Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices] to synchronize all the data to the device including the new users.
For more details, please refer to the ZKBioSecurity User Manual.

9

Method 3: Register on the phone

1. Click [Personnel] > [Parameters], input `'http://Server address: Port'' in the QR Code UGL bar. The software will automatically generate a QR code. Scan the QR code or login onto `'http://Server address: Port/app/v1/adreg''by the mobile phone to register users.

Personnel Registration
Personnel Registration
Personnel ID 1 First Name Mike Last Name Last Name

Position Dismissed Personnel

Personnel ID Setting

The Maximum Length:

15

Support Letters:

Yes

No

Personnel ID Auto-increment: Yes

No

Card Setting

The Maximum Length: 32

Card Format Display:

Decimal

Multiple Cards per Person: Yes

Bits(Binary)

Hexadecimal No

Temporary Personnel Setting

Enable Temporary Personnel Auto-audit: Yes

No

Self-service Registration
Enable the declaration of health information: QR Code URL: http://Server address:Port Download QR code image

Yes

No

Card Management

2. The users will be displayed in [Personnel] > [Temporary Personnel], click [Review].

Position Dismissed Personnel

Personnel ID

The current query conditions None

Refresh

Delete

Personnel ID First Name

Name Last Name

1

Mike

Mobile Phone

Welcome, admin

Status

Create Time

Operations

Delete

Card Management

1-1

50 rows per page

Jump To 1

/0 Page Total of 0 records

10

13 Access Control Settings
Clickon > [Access Control]to enter the access control management interface and set relevant parameters of access control.

Main Menu

User Mgt. User Role

COMM.

System

Personalize

L Data Mgt. Access Control

Attendance Search

Print

Autotest System Info

Access Control Access Control Options Time Rule Settings Holidays Combined Verification Anti-passback Setup Duress Options

Access Control Options Gate Control Mode

Door Lock Delay (s)

5

Door Sensor Delay (s)

10

Door Sensor Type

None

Verification Mode

Face+Password

Door Available Time Period

1

Normal Open Time Period

None

Master Device

In

Slave Device

Out

Auxiliary Input Configuration

Verify Mode by RS485

Speaker Alarm

14 Ethernet and Cloud Server Settings
Clickon > [Comm.] > [Ethernet]to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface. Clickon > [Comm.] > [Cloud Server Setting] to set the server address and server port,that is, the IP address and port number of the server after the software is installed. If the device communicates with the server successfully, the icon will be displayed in the upper right corner of the standby interface.

Main Menu

User Mgt. User Role

L COMM.

System

Personalize

Data Mgt. Access Control Attendance Search

Print

Autotest System Info

IP Address

Ethernet

Subnet Mask

Gateway

DNS

TCP COMM. Port

DHCP

Display in Status Bar

192.168.163.150 255.255.255.0 192.168.163.1 0.0.0.0 4370

Cloud Server Setting Server mode Enable Domain Name Server Address Server port Enable Proxy Server HTTPS

ADMS
0.0.0.0 8081

11

15 Detection Management
Clickon > [Detection Management]to enter the setting interface.
1 You can enable mask detection function, and enable the Deny Access Without Mask and the Trigger External Alarm, the device will send an alarm prompt when the user doesn't wear a mask, meanwhile the user will be forbidden to access, as shown in the following figure.
2 When the Allow Unregistered People to Access is enabled, you can also set Enable Capture of Unregistered Person to save the user photo.

Main Menu

User Mgt. User Role

COMM.

L System

Personalize

Data Mgt. Access Control Attendance Search

Print

Autotest System Info

Date Time

System

Access Logs Settings

Face

Video Intercom Parameters

Temperature Mgt.
L Detection Management
Device Type Settings

Security Settings

Reset

Detection Management Enable Mask Detection

Deny Access Without Mask

Allow Unregistered People to Access

Enable Capture of Unregistered Person

Trigger External Alarm Clear External Alarm

External Alarm Delay(s)

10

Update Firmware

08:50

08:50

Mask Detected
Successfully verified.
Name:Mike User ID:1 Verify:Face

Without Mask
Failed to verify.
Verify:Face User ID:1

12

16 Multi-face Identifying Settings
Clickon > [System]> [Face] > [Face Identifying Settings] > [Identifying Mode] > [Multi-face Identifying] to enter the setting interface.
When the Multi-face Identifying is enabled, the device can perform facial recognition of multiple people at once. For more details, please refer to the User Manual.

Main Menu

User Mgt. User Role

COMM.

L System

Personalize

Data Mgt. Access Control Attendance Search

Print

Autotest System Info

Date Time

System

Access Logs Settings
L Face
Video Intercom Parameters

Temperature Mgt.

Detection Management

Device Type Settings

Security Settings

Reset

Face Anti-Spoofing Settings

Camera Exposure Settings

Face Identifying Settings

Flash Light Sensitivity

100

Motion Detection Sensitivity

4

Face Algorithm

Face Identifying Settings

1:N Threshold Value

90

1:1 Threshold Value

88

Face Enrollment Threshold

70

68

Face Pitch Angle

25

Face Rotation Angle

30

Image Quality

40

Minimum Face Size

80

Identifying Mode

Face Comparison Interval(s)

1

Visible-Infra Light Hybrid Matching Mode

Identifying Mode Multi-face Identifying

Content Mode to Display

User ID+Timestamp

Count to Display

3

Tracking Identification

13

17 Video Door Phone Connection
Visitors click the on the main interface of the device to call and the phone will ring. The user can select accept or decline the call. After the user accepting, it will enter the video door phone interface.
1. On the device, click on > [System] > [Video Intercom Parameters] > [QR Code Binding].
2. Download and install the ZSmart APP on the phone, open the APP and add the device by scanning the QRcode.

Date Time

System

Access Logs Settings

Face
L Video Intercom Parameters
Temperature Mgt.

Detection Management

Device Type Settings

Security Settings

Reset

L
13

18 QR Code as the Mobile Credential
1. In [System] > [Basic Management] > [Parameters] of ZKBioSecurity software, set Enable QR Code to"Yes", and select the QR code status according to the actual situation.
2. On the server, choose [System] > [Authority Management] > [Client Register] to add a registered App client.
3. Open the APP, enter the IP address or domain name of the server, and its port number, scan the Register QR-code. After the connection is successful, tap on Employee to switch to the Employee Login screen. Enter the Employee ID and Password (Default: 123456) to login.
4. Tap [Mobile Credential] on the APP, and a QR code will appear. Place the phone screen right in front of the device QR code scanner. For details, please refer to the ProFace x (DS) User Manual.
Note: 1. Place your phone within 15-50cm of the device (distance depends on the size of the phone
screen and the density of the QR code). Do not block the camera and the QR code. 2. For more details of Dynamic QR Code, please refer the ZKBioSecurity Mobile APP User Manual.
14

ZKTeco Industrial Park, No. 32, Industrial Road,

Tangxia Town, Dongguan, China.

Phone : +86 769 - 82109991

Fax

: +86 755 - 89602394

www.zkteco.com

Copyright@2022 ZKTECO CO., LTD. All Rights Reserved.



References

Corel PDF Engine Version 22.1.1.523 CorelDRAW 2020