User Guide for ZKTeco models including: ProFace X DS, ProFace X, ProFace DS, ProFace
ZKTeco Malaysia
Index of /wp-content/uploads/download-manager-files/
File Info : application/pdf, 17 Pages, 39.90MB
DocumentDocumentQuick Start Guide ProFace X (DS) Version: 1.0 Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual. 1Overview Near-infrared Flash Microphone Camera 8-inch Touchscreen Under-screen Card Reading Area Tamper Switch Speaker Reset Button RS232 RS485 12V 12V GND GND GND RXD1 TXD1 485B 485A GND 12V Wiegand Out Wiegand In WD1 WD0 INWD1 INWD0 GND 12V Power interface +12V GND GND AUX GND SEN GND BUT NO COM NC ALAL+ Power Auxiliary input Sensor Exit button Lock Alarm Networkinterface Note: Not all products have the function with , the real product shall prevail. 1 2 Installation Environment Please refer to the following recommendations for installation. 6.5ft 10ft KEEP DISTANCE window AVOID GLASS REFRACTION 3 Device Installation AVOID DIRECT SUNLIGHT AND EXPOSURE KEEP EFFECTIVE DISTANCE 0.3-2.5m Install on the wall Attach the mounting template sticker to the wall, and drill holes according to the mounting paper. Fix the backplate on the wall using wall mounting screws. Attach the device to the backplate. Fasten the device to the backplate with a security screw. 1 2 1.5m 3 4 2 3 Device Installation Install on the barrier gate Please thread the wire through the bracket before installation. Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut. Adjust the angle of the device. 1 2 30mm 3 4 Standalone Installation Alarm Door Sensor Reader Lock DSemteockteor Exit Button TCP/IP PC 5 Door Sensor, Exit Button & Alarm Connection Detector Power + COM GND NO AUX SmokeDetector GND SEN GND BUT Door Sensor ExitButton NO COM Alarm NC - + AL- AL+ - + Alarm Power 4 6 Lock Relay Connection The system supports Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally unlocked when power-on) is connected with 'NO' and 'COM' terminals, and the NC LOCK (normally locked when power-on) is connected with 'NC' and 'COM' terminals. Take NC Lock as an example below: 1)Device not sharing power with the lock2)Devicesh aring power with the lock DC12V GND +12V DC12V +12V GND Maximum 30V 3A input. DC12V FR107 Normally Closed Lock GND AUX GND SEN GND BUT NO COM NC ALAL+ FR107 Normally Closed Lock GND AUX GND SEN GND BUT NO COM NC ALAL+ 7 Wiegand Reader Connection WD1 WD0 INWD1 INWD0 GND 12V 5 Access controller GND +12V Wiegand reader 8 Barrier Connection 12V 12V GND GND GND RXD1 TXD1 485B 485A GND 12V Barrier gate 9 RS485 Connection 12V 12V GND GND GND RXD1 TXD1 485B 485A GND 12V +12V GND 485485+ GND 485 reader Note: 485A and 485B can be connected to the Barrier gate or the 485 Reader, separately, but cannot be connected to the gate and reader at the same time. 6 10 Power Connection 12V3ADC Recommended power supply: 12V - 3A To share the power with other devices, use a power supply with higher current ratings. 11 Ethernet Connection Connect the device and computer software over an Ethernet cable. An example is shown below: ZKBioSecurity Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0 IP address: 192.168.1.130 Subnet mask: 255.255.255.0 Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to ZKBioSecurity software. Click on [Comm.] > [Ethernet] > [IP Address], input the IP address and click on [OK]. 7 12 UserRegistration When there is no super administrator set in the device, click on to enter the menu. After setting the super administrator, the system will request for the administrator's verification before entering the menu. For the security purpose, it is recommended to register a super administrator at the first time you use the device. Method1: Register on the device Clickon> [User Mgt.] > [New User] to register a new user. Settings include entering user ID and name, face, card, password and profile photo, setting user role and access control role. Main Menu L User Mgt. User Role COMM. System Personalize Data Mgt. Access Control Attendance Search New User User Mgt. All Users Display Style Print Autotest System Info L User ID Name New User User Role Face Card Number Password Profile Photo Access Control Role 1 Mike Normal User ********** Enroll Card Number Card Number:1311129048 Enroll Face 8 Method2: Register on ZKBioSecurity software Please set the IP address and cloud service server address in the Comm. Menu option on the device. 1. Click [Access] > [Access Device] > [Device] > [Search Device] to search the device on the software. When an appropriate server address and port is set on the device, the searched devices are displayed automatically. Refresh New Delete Export Search Device Device Control Set up Search Total Progress IP Address Step 1 Search Device No device found? Download Search Tools to Local Disk Step 2 Searched devices count:2 Number of devices added:1 Device Type Serial Number IP Address 192.168.0.31 192.168.10.214 MAC Address Subnet Mask Gateway Address Serial Number Device Type 255.255.255.0 192.168.0.1 XXXX000000000 S*********** 255.255.255.0 192.168.1.1 XXXX000000000 ProFace X (DS) View and Get Device Info Communication Set Server Operations Step 3 This device has been added Add Add Device Name* 192.168.4.18 Icon Type* Door Area* Area Name Add to Level Clear Data in the Device when Adding The current systen communication port is 8088, please make sure the device is set correctly. [Clear Data in the Device when Adding] will delete data in the device (except event record), please use with caution! Step 4 OK Cancel 2. Click [Add] in operation column, a new window will pop-up. Select Icon type, Area, and Add to Level from each dropdowns and click [OK] to add the device. 3. Click [Personnel] > [Person] > [New] and fill in all the required fields to register a new users in the software. 4. Click [Access] > [Device] > [Device Control] > [Synchronize All Data to Devices] to synchronize all the data to the device including the new users. For more details, please refer to the ZKBioSecurity User Manual. 9 Method 3: Register on the phone 1. Click [Personnel] > [Parameters], input `'http://Server address: Port'' in the QR Code UGL bar. The software will automatically generate a QR code. Scan the QR code or login onto `'http://Server address: Port/app/v1/adreg''by the mobile phone to register users. Personnel Registration Personnel Registration Personnel ID 1 First Name Mike Last Name Last Name Position Dismissed Personnel Personnel ID Setting The Maximum Length: 15 Support Letters: Yes No Personnel ID Auto-increment: Yes No Card Setting The Maximum Length: 32 Card Format Display: Decimal Multiple Cards per Person: Yes Bits(Binary) Hexadecimal No Temporary Personnel Setting Enable Temporary Personnel Auto-audit: Yes No Self-service Registration Enable the declaration of health information: QR Code URL: http://Server address:Port Download QR code image Yes No Card Management 2. The users will be displayed in [Personnel] > [Temporary Personnel], click [Review]. Position Dismissed Personnel Personnel ID The current query conditions None Refresh Delete Personnel ID First Name Name Last Name 1 Mike Mobile Phone Welcome, admin Status Create Time Operations Delete Card Management 1-1 50 rows per page Jump To 1 /0 Page Total of 0 records 10 13 Access Control Settings Clickon > [Access Control]to enter the access control management interface and set relevant parameters of access control. Main Menu User Mgt. User Role COMM. System Personalize L Data Mgt. Access Control Attendance Search Print Autotest System Info Access Control Access Control Options Time Rule Settings Holidays Combined Verification Anti-passback Setup Duress Options Access Control Options Gate Control Mode Door Lock Delay (s) 5 Door Sensor Delay (s) 10 Door Sensor Type None Verification Mode Face+Password Door Available Time Period 1 Normal Open Time Period None Master Device In Slave Device Out Auxiliary Input Configuration Verify Mode by RS485 Speaker Alarm 14 Ethernet and Cloud Server Settings Clickon > [Comm.] > [Ethernet]to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface. Clickon > [Comm.] > [Cloud Server Setting] to set the server address and server port,that is, the IP address and port number of the server after the software is installed. If the device communicates with the server successfully, the icon will be displayed in the upper right corner of the standby interface. Main Menu User Mgt. User Role L COMM. System Personalize Data Mgt. Access Control Attendance Search Print Autotest System Info IP Address Ethernet Subnet Mask Gateway DNS TCP COMM. Port DHCP Display in Status Bar 192.168.163.150 255.255.255.0 192.168.163.1 0.0.0.0 4370 Cloud Server Setting Server mode Enable Domain Name Server Address Server port Enable Proxy Server HTTPS ADMS 0.0.0.0 8081 11 15 Detection Management Clickon > [Detection Management]to enter the setting interface. 1 You can enable mask detection function, and enable the Deny Access Without Mask and the Trigger External Alarm, the device will send an alarm prompt when the user doesn't wear a mask, meanwhile the user will be forbidden to access, as shown in the following figure. 2 When the Allow Unregistered People to Access is enabled, you can also set Enable Capture of Unregistered Person to save the user photo. Main Menu User Mgt. User Role COMM. L System Personalize Data Mgt. Access Control Attendance Search Print Autotest System Info Date Time System Access Logs Settings Face Video Intercom Parameters Temperature Mgt. L Detection Management Device Type Settings Security Settings Reset Detection Management Enable Mask Detection Deny Access Without Mask Allow Unregistered People to Access Enable Capture of Unregistered Person Trigger External Alarm Clear External Alarm External Alarm Delay(s) 10 Update Firmware 08:50 08:50 Mask Detected Successfully verified. Name:Mike User ID:1 Verify:Face Without Mask Failed to verify. Verify:Face User ID:1 12 16 Multi-face Identifying Settings Clickon > [System]> [Face] > [Face Identifying Settings] > [Identifying Mode] > [Multi-face Identifying] to enter the setting interface. When the Multi-face Identifying is enabled, the device can perform facial recognition of multiple people at once. For more details, please refer to the User Manual. Main Menu User Mgt. User Role COMM. L System Personalize Data Mgt. Access Control Attendance Search Print Autotest System Info Date Time System Access Logs Settings L Face Video Intercom Parameters Temperature Mgt. Detection Management Device Type Settings Security Settings Reset Face Anti-Spoofing Settings Camera Exposure Settings Face Identifying Settings Flash Light Sensitivity 100 Motion Detection Sensitivity 4 Face Algorithm Face Identifying Settings 1:N Threshold Value 90 1:1 Threshold Value 88 Face Enrollment Threshold 70 68 Face Pitch Angle 25 Face Rotation Angle 30 Image Quality 40 Minimum Face Size 80 Identifying Mode Face Comparison Interval(s) 1 Visible-Infra Light Hybrid Matching Mode Identifying Mode Multi-face Identifying Content Mode to Display User ID+Timestamp Count to Display 3 Tracking Identification 13 17 Video Door Phone Connection Visitors click the on the main interface of the device to call and the phone will ring. The user can select accept or decline the call. After the user accepting, it will enter the video door phone interface. 1. On the device, click on > [System] > [Video Intercom Parameters] > [QR Code Binding]. 2. Download and install the ZSmart APP on the phone, open the APP and add the device by scanning the QRcode. Date Time System Access Logs Settings Face L Video Intercom Parameters Temperature Mgt. Detection Management Device Type Settings Security Settings Reset L 13 18 QR Code as the Mobile Credential 1. In [System] > [Basic Management] > [Parameters] of ZKBioSecurity software, set Enable QR Code to"Yes", and select the QR code status according to the actual situation. 2. On the server, choose [System] > [Authority Management] > [Client Register] to add a registered App client. 3. Open the APP, enter the IP address or domain name of the server, and its port number, scan the Register QR-code. After the connection is successful, tap on Employee to switch to the Employee Login screen. Enter the Employee ID and Password (Default: 123456) to login. 4. Tap [Mobile Credential] on the APP, and a QR code will appear. Place the phone screen right in front of the device QR code scanner. For details, please refer to the ProFace x (DS) User Manual. Note: 1. Place your phone within 15-50cm of the device (distance depends on the size of the phone screen and the density of the QR code). Do not block the camera and the QR code. 2. For more details of Dynamic QR Code, please refer the ZKBioSecurity Mobile APP User Manual. 14 ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 - 82109991 Fax : +86 755 - 89602394 www.zkteco.com Copyright@2022 ZKTECO CO., LTD. All Rights Reserved.