Lennox Rooftop Units Manuals
PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS XP16 ELITE® Series R-410A - Two-Stage Compressor Bulletin No. 210463 October 2017 Supersedes August 2017 SEER up to 17.00 2 to 5 Tons Cooling Capacity - 23,600 to 59,000 Btuh Heating Capacity - 21,000 to 61,500 Btuh MODEL NUMBER IDENTIFICATION Refrigerant Type X = R-410A Unit Type P = Heat Pump Outdoor Unit Series x p 16 - 036 - 230 - 6 Minor Revision Number Voltage 230 = 208/230V-1phase-60hz Nominal Cooling Capacity 024 = 2 tons 036 = 3 tons 048 = 4 tons 060 = 5 tons FEATURES CONTENTS AHRI System Matches............................................... 10 Dimensions................................................................... 7 Electrical Data.............................................................. 6 Features....................................................................... 2 Field Wiring................................................................... 8 Installation Clearances................................................. 8 Model Number Identification......................................... 1 Optional Accessories - Order Separately..................... 6 Sound Data................................................................... 8 Specifications............................................................... 6 WARRANTY Compressor - Limited warranty for ten years in residential installations and five years in non-residential installations. All other covered components - Five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AHRI Certified to AHRI Standard 210/240-2008. Sound rated in Lennox reverberant sound test room in accordance with test conditions included in AHRI Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated according to U.S. Department of Energy (DOE) test procedures. Air conditioners and components within bonded for grounding to meet safety standards for servicing required by UL and CEC. Units are ETL certified for the U.S. and Canada. ISO 9001 Registered Manufacturing Quality System. For expanded ratings, see www.LennoxPROs.com. B C J I D H K E G F APPLICATIONS SEER up to 17.00. HSPF (region IV) up to 9.50. 2 through 5 ton. Single phase power supply. Sound levels as low as 74 dB. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Designed for applications with remotely located indoor air handler units or gas furnaces with indoor add-on coils. When heat pumps are used with gas furnaces, a dual-fuel compatible thermostat or a zone control system with dual-fuel capabilities must be used (order separately). Units shipped completely factory assembled, piped, and wired. Each unit is test operated at the factory insuring proper operation. Installer must set heat pump, connect refrigerant lines, and make electrical connections to complete job. XP16 - 2 to 5 Ton Heat Pump / Page 2 FEATURES REFRIGERATION SYSTEM R-410A Refrigerant Non-chlorine, ozone friendly, R-410A. Unit is factory pre-charged. See Specification table. Total system refrigerant charge is dependant on outdoor unit size, indoor unit size and refrigerant line length. Refer to the unit-mounted charging sticker to determine correct amount of charge required. AB Outdoor Coil Fan Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. 060 models have a variable-speed outdoor fan motor for quiet operation. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has sleeve bearings and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion Fan guard constructed of corrosion-resistant PVC (polyvinyl chloride) coated steel. Fan service access accomplished by removal of fan guard. C Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple-edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Inverted coil circuiting prevents ice buildup at coil base in low ambients. Discharge gas enters bottom of coil during defrost and heat of refrigerant flows counter to water drainage resulting in extremely clean and unobstructed fins and tubes. Fin spacing allows rapid and complete water drainage. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to insure leakproof construction. Entire coil is accessible for cleaning. D Expansion Valve - Outdoor Unit Designed and sized specifically for use in heat pump system. Sensing bulb is located on the line between reversing valve and the coil thus sensing suction temperature in the heat cycle. Factory installed and piped. Discharge Temperature Switch Shuts off unit if operating conditions cause the compressor discharge line temperature to rise above setpoint. Protects compressor from excessive pressure / temperature. Automatic reset when temperature drops below setpoint. E High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Auto-reset. F Low Pressure Switch Shuts off unit if suction pressure falls below setting. Provides loss of charge and freeze-up protection. Auto-reset. G Hi-Capacity Liquid Line Drier Factory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system. 100% molecular-sieve bead type drier. H Reversing Valve 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa. Valve operates on pressure differential between outdoor unit and indoor unit of the system. Factory installed. Optional Accessories Expansion Valve Kits Must be ordered separately and field installed on certain indoor units. See TXV Usage table. Chatleff style fitting. Freezestat Installs on or near the discharge line of the evaporator or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below its setpoint. Opens at 29°F and closes at 58°F. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized, and sealed at factory. Suction line fully insulated. L15 lines are stubbed at both ends. See Specifications table for selection. Not available for -060 model and must be field fabricated. XP16 - 2 to 5 Ton Heat Pump / Page 3 FEATURES COMPRESSOR I Copeland Scroll Ultra TechTM Two-Stage Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. During the compression process, there are several pockets in the scroll that are compressing gas. Modulation is achieved by venting a portion of the gas in the first suction pocket back to the low side of the compressor thereby reducing the effective displacement of the compressor. A 24-volt DC solenoid valve inside the compressor controls staging. When the 3-way solenoid is energized it moves the lift ring assembly to block the ports and the compressor operates at full-load or 100% capacity. When the solenoid is de-energized the lift ring assembly moves to unblock the compressor ports and the compressor operates at part-load or approximately 67% of its full-load capacity. XP16 - 2 to 5 Ton Heat Pump / Page 4 The "loading" and "unloading" of the two stage scroll is done "on the fly" without shutting off the single-speed compressor motor between stages. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on specially formulated, resilient rubber mounts for better sound dampening and vibration free operation. Crankcase Heater Crankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication. CONTROLS J Defrost Control Control furnished as standard. Gives a demand defrost cycle whenever system heating performance falls below optimum levels. The sensing element on coil determines when defrost cycle is required and when to terminate cycle. Anti-short cycle (5 minutes) incorporated into the board. Diagnostic LED's furnished as an aid in troubleshooting. Conveniently located in control box. Optional Accessories Blower Relay Kit (For Use With EL195E and ML180E Gas Furnaces) Allows furnace blower speed changes when matched with two-stage heat pumps. ComfortSense® 7500 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/2 Cool. Auto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol® control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. See the ComfortSense 7500 Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor for ComfortSense® 7500 Thermostat Allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol® applications. FEATURES CONTROLS (continued) Optional Accessories Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally does not need a potential relay and start capacitor. In conditions such as low voltage, kit may be required to increase the compressor starting torque. Hard start kit is required in applications where the supply voltage is less than 230V. Indoor Blower Off Delay Relay Delays the indoor blower-off time during the cooling cycle. See AHRI Rating Tables for usage. Indoor Blower Speed Relay Kit Relay kit provides the option of changing blower speeds on standard permanent split capacitor (PSC) multi-tap blower motors during cooling operation. Provides optimum humidity control conditions by automatically reducing indoor blower speed during continuous fan operation or low stage compressor operation to reduce humidity levels. Low Ambient Kit Heat pump will operate in the cooling mode satisfactorily down to 45°F outdoor air temperature without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30°F. A Freezestat should be installed on compressors equipped with a low ambient kit. A Compressor Low Ambient Cut-Off should be added to terminate compressor operation below recommended operation conditions (on/off operation, 30°F or modulating operation, 0°F. Mild Weather Kit Heat pump units operate satisfactorily in the heating mode at outdoor air temperatures up to 75°F. Mild Weather Kit can be field installed, allowing heating operation above 75°F. CABINET Heavy-gauge steel construction Pre-painted cabinet finish. Control box is conveniently located with all controls factory wired. Large removable panel provides service access. Drainage holes are provided in base section for moisture removal. High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture. PermaGuardTM Unit Base Durable zinc-coated base section resists rust and corrosion. K SmartHingeTM Louvered Coil Protection Steel louvered panels provides complete coil protection. Panels are hinged to allow easy cleaning and servicing of coils. Panels may be completely removed. Interlocking tabs and slots assure tight fit on cabinet. Refrigerant Line Connections, Electrical Inlets and Service Valves Vapor and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Vapor valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See dimension drawing. Optional Accessories Monitor Kit - Service Light Contains ambient compensating thermistor and service light thermostat. For use with thermostats requiring input for indicator lights. Outdoor Thermostat Kit An outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where twostage control is applicable. Outdoor thermostat maintains the heating load on the low power input as long as possible before allowing the full power load to come on the line. Thermostat kit and mounting box must be ordered extra. Snow Guards For use in locations where the possibility of heavy snow or freezing rain accumulation may occur. Heavy gauge powder coated steel guard deflects snow and ice away from the outdoor fan and prevents buildup on the fan guard. XP16 - 2 to 5 Ton Heat Pump / Page 5 SPECIFICATIONS General Data Model No. Nominal Tonnage Connections (sweat) Liquid line (o.d.) - in. Vapor line (o.d.) - in. Refrigerant 1 R-410A charge furnished Outdoor Coil Net face area - sq. ft. Outer coil Inner coil Tube diameter - in. No. of rows Fins per inch Outdoor Fan Diameter - in. No. of blades Motor hp Cfm - 1st stage 2nd stage Rpm - 1st stage 2nd stage Watts - 1st stage 2nd stage Shipping Data - lbs. 1 pkg. XP16-024 2 3/8 3/4 8 lbs. 11 oz. 15.21 14.50 5/16 2 22 18 3 1/10 2232 - - 1035 - - 145 - - 222 XP16-036 3 3/8 7/8 10 lbs. 6 oz. 21.00 20.27 5/16 2 22 22 4 1/4 3900 - - 830 - - 295 - - 273 XP16-048 4 3/8 7/8 10 lbs. 9 oz. 22.17 21.51 5/16 2 2 26 3 1/3 4100 - - 855 - - 265 - - 294 XP16-060 5 3/8 1-1/8 11 lbs. 8 oz. 29.09 28.16 5/16 2 22 26 3 1/3 3690 4250 700 820 130 195 353 ELECTRICAL DATA Line voltage data - 60hz 2 Maximum overcurrent protection (amps) 3 Minimum circuit ampacity Compressor Rated load amps Locked rotor amps Power factor Outdoor Coil Fan Motor Full load amps 4 208/230V-1ph 25 15.3 11.70 58.3 0.98 0.7 4 208/230V-1ph 35 20.8 15.3 83 0.99 1.7 4 208/230V-1ph 45 28.3 21.20 104 0.99 1.8 4 208/230V-1ph 60 36.8 27.1 152.9 0.99 2.8 OPTIONAL ACCESSORIES - ORDER SEPARATELY Blower Relay Kit - for EL195E and 85W66 · · · · ML180E gas furnaces ComfortSense® 7500 Thermostat 13H14 · · · · Outdoor Temperature Sensor - for X2658 · · · · ComfortSense® 7500 Thermostat Compressor Hard Start Kit - Required 63W22 · in applications with less than 230V 10J42 · · 63W24 · Freezestat 3/8 in. tubing 93G35 · · · · 5/8 in. tubing 50A93 · · · · Indoor Blower Speed Relay Kit 40K58 · · · · Indoor Blower Off Delay Relay 58M81 · · · · 5 Low Ambient Kit 54M89 · · · 68M04 · Mild Weather Kit 33M07 · · · · Monitor Kit - Service Light 76F53 · · · · Outdoor Thermostat 56A87 · · · · Thermostat Kit Mounting Box 31461 · · · · Refrigerant L15-41-20 L15-41-40 · Line Sets L15-41-30 L15-41-50 L15-65-30 L15-65-40 · · L15-65-50 Field Fabricate · 6 Snow Guards 28-1/2 x 27-1/2 in. X8781 · 39-1/2 x 35-5/8 in. Y1033 · · · NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Hard start kit is required in applications where the supply voltage is less than 230V. 5 Compressor Low Ambient Cut-Off and Freezestat are recommended with Low Ambient Kit. 6 Adds 11-1/2 inches (292 mm) to unit height. XP16 - 2 to 5 Ton Heat Pump / Page 6 DIMENSIONS - INCHES (MM) TOP VIEW C DISCHARGE AIR SIDE VIEW UNIT SUPPORT FEET SUCTION LINE CONNECTION LIQUID LINE CONNECTION B LIQUID LINE CONNECTION ELECTRICAL INLETS SUCTION LINE CONNECTION 4-3/4 4-1/4(108) (121) A 2 (51) 1 (25) END VIEW UNIT SUPPORT FEET 8-1/2 (216) 9-1/2 (241) 16-7/8 (429) 26-7/8 (683) 8-3/4 (222) 8-1/4 (210) 5-1/2 (140) 13-1/2 (343) XP16-024 BASE SECTION (Small Base) 8-3/4 (222) 3-3/4 (95) 3-1/8 (79) 30-3/4 (781) 4-5/8 (117) XP16-036 TO -060 BASE SECTION (Large Base) Model No. XP16-024 XP16-036 XP16-048 XP16-060 A B C in. mm in. mm in. mm 35 889 27 686 28 711 35 889 35-1/2 902 39-1/2 1003 35 889 35-1/2 902 39-1/2 1003 45 1143 35-1/2 902 39-1/2 1003 XP16 - 2 to 5 Ton Heat Pump / Page 7 FIELD WIRING DISCONNECT SWITCH (By Others) A OPTIONAL OUTDOOR THERMOSTAT LENNOX OUTDOOR UNIT OPTIONAL ELECTRIC HEAT LENNOX INDOOR UNIT D B DISCONNECT SWITCH (By Others) THERMOSTAT (Optional) C A - Two Wire Power (see Electrical Data) B - Two or Three Wire Power (size to heater capacity) C - Twelve Wire Low Voltage 18 ga. minimum Fourteen Wire Low Voltage with Optional Outdoor Thermostat D - Eight Wire Low Voltage 18 ga. minimum Ten Wire Low Voltage with Optional Outdoor Thermostat NOTE - Field Wiring Not Furnished All wiring must conform to NEC or CEC and local electrical codes. SOUND DATA 1 Unit Model No. 125 250 500 XP16-024 72.0 70.0 69.5 XP16-036 72.5 71.5 73.0 XP16-048 72.5 71.5 73.0 XP16-060 72.5 73.5 77.5 NOTE - the octave sound power data does not include tonal correction. 1 Tested according to AHRI Standard 270-2008 test conditions. 1000 68.5 70.5 70.5 72.5 2000 63.5 66.0 66.0 67.0 4000 58.0 60.5 60.5 62.5 8000 56.5 58.5 58.5 58.5 1 Sound Rating Number (dB) 74 76 76 78 INSTALLATION CLEARANCES NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm). A clearance of 24 in. must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. XP16 - 2 to 5 Ton Heat Pump / Page 8 See NOTES See NOTES See NOTES See NOTES Control Box TXV USAGE Use this table for C33, CH23, CH33 and CR33 Field Installed TXV Match-Ups. Model No. Order No. XP16-024 12J18 XP16-036 12J19 XP16-048 12J20 XP16-060 12J20 CX34 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. C33 and CH33 coils - Replace the factory installed orifice with the expansion valve listed. CR33 and CH23 - Use the expansion valve listed. MOST POPULAR MATCHES Outdoor Unit Model No. Indoor Unit Model No XP16-024 CBX32MV-024/030 XP16-036 CBX32MV-036 XP16-048 CBX32MV-060 XP16-060 CBX32MV-060 AHRI STANDARD 210/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated. XP16 - 2 to 5 Ton Heat Pump / Page 9 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-024-230 24200 16 12.5 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 21600 13300 3.64 2.48 8.5 C33-38A Furnace SL280UH070V36A AHRI Reference 7785776 XP16-024-230 24200 15.1 12.5 21600 13300 3.64 2.48 8.5 C33-38A SL280UH070XV36A 7785773 XP16-024-230 24000 16 12.5 21600 13300 3.6 2.46 8.5 C33-38B EL296UH070XV36B 7785768 XP16-024-230 24200 XP16-024-230 24000 XP16-024-230 23800 XP16-024-230 23800 XP16-024-230 23800 16 12.5 21600 13300 3.66 2.5 8.5 16 12.5 21600 13300 3.6 2.46 8.5 16 12.2 22400 13900 3.34 2.44 8.5 16 12.2 22400 13900 3.34 2.44 8.5 15.5 12.2 22400 13900 3.34 2.42 8.5 C33-38B C33-38B C35-30A C35-30A C35-30B SL280UH090V36B SLP98UH070XV36B SL280UH070V36A SL280UH070XV36A EL296UH070XV36B 7785762 7785767 9910944 9910945 9910946 XP16-024-230 23600 15 12.2 22400 13800 3.36 2.44 8.5 C35-30B SL280UH090V36B 9910947 XP16-024-230 23800 15.5 12.2 22400 13900 3.34 2.42 8.5 C35-30B SLP98UH070XV36B 9910948 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 16 12.2 22200 13700 3.52 2.42 8.5 16 12.2 22200 13700 3.52 2.42 8.5 15.5 12.2 22200 13700 3.52 2.42 8.5 15 12.5 22000 13600 3.5 2.42 8.2 15.5 12.2 22200 13700 3.52 2.42 8.5 C35-36A C35-36A C35-36B C35-36B C35-36B SL280UH070V36A SL280UH070XV36A EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B 9910949 9910950 9910951 9910952 9910953 XP16-024-230 24200 16 12.5 21600 13300 3.64 2.48 8.5 C37-38A SL280UH070V36A 10084930 XP16-024-230 24200 15.1 12.5 21600 13300 3.64 2.48 8.5 C37-38A SL280UH070XV36A 10084929 XP16-024-230 24000 XP16-024-230 24200 XP16-024-230 24000 XP16-024-230 24000 XP16-024-230 24000 16 12.5 21600 13300 3.6 2.46 8.5 16 12.5 21600 13300 3.66 2.5 8.5 16 12.5 21600 13300 3.6 2.46 8.5 15.5 12 22600 13600 3.6 2.54 8.5 14.5 12 23400 14400 3.4 2.42 8.2 C37-38B C37-38B C37-38B CBA27UHE-024 CBX25UHV-030 EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B 10084926 10084923 10084925 10258586 7785764 XP16-024-230 24200 15.5 11.2 22400 13700 3.7 2.54 8.5 CBX27UH-024 7785754 XP16-024-230 24000 16 12.5 22200 12900 3.62 2.38 8.5 CBX27UH-030 7785755 XP16-024-230 24400 16.5 12.5 22400 14000 3.72 2.6 8.5 CBX32MV-024/030 7785758 XP16-024-230 24400 17 XP16-024-230 24200 16 XP16-024-230 24000 16 XP16-024-230 24400 16 XP16-024-230 24800 16 12.5 22400 13100 3.66 2.38 8.5 12 22200 13000 3.6 2.38 8.5 12 22200 12900 3.6 2.36 8.5 12.5 22400 13100 3.68 2.4 8.5 12 21000 13900 3.3 2.5 8.5 CBX32MV-036 CBX40UHV-024 CBX40UHV-030 CBX40UHV-036 CH33-31B EL296UH070XV36B 7785757 7785759 7785756 7785765 7785771 XP16-024-230 24800 15.1 12.2 21000 13900 3.34 2.52 8.2 CH33-31B SL280UH090V36B 7785775 XP16-024-230 24800 16 12 21000 13900 3.3 2.5 8.5 CH33-31B SLP98UH070XV36B 7785774 XP16-024-230 23800 XP16-024-230 23800 XP16-024-230 23800 XP16-024-230 23600 XP16-024-230 23600 15.5 12.2 21800 13600 3.24 2.3 8.2 15 12.2 21600 13500 3.24 2.3 8.2 15.5 12.2 21800 13600 3.24 2.3 8.2 16 12.5 23200 13900 3.36 2.34 8.2 16 12.5 23200 13900 3.36 2.36 8.2 CH35-30B CH35-30B CH35-30B CR33-30/36 CR33-30/36 EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B SLP98DF070XV36B SLP98DF090XV36C 9910941 9910942 9910943 7785772 7785766 XP16-024-230 24200 16 12.5 21600 13300 3.64 2.48 8.5 CX34-38A SL280UH070V36A 7785760 XP16-024-230 24200 16 12.5 21600 13300 3.64 2.48 8.5 CX34-38A SL280UH070XV36A 7785770 XP16-024-230 24200 16 XP16-024-230 24400 16 XP16-024-230 24000 16 XP16-024-230 23800 16 XP16-024-230 23800 16 12.5 21600 13400 3.62 2.48 8.5 12.5 21800 13400 3.68 2.48 8.5 12.5 21600 13300 3.6 2.46 8.5 12.2 22400 13900 3.34 2.44 8.5 12.2 22400 13900 3.34 2.44 8.5 CX34-38B CX34-38B CX34-38B CX35-30A CX35-30A EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B SL280UH070V36A SL280UH070XV36A 7785769 7785761 7785763 9910931 9910932 XP16-024-230 23800 15.5 12.2 22400 13900 3.34 2.42 8.5 CX35-30B EL296UH070XV36B 9910933 XP16-024-230 23600 15 12.2 22400 13800 3.36 2.44 8.5 CX35-30B SL280UH090V36B 9910934 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 10 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-024-230 23800 15.5 12.2 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 22400 13900 3.34 2.42 8.5 CX35-30B Furnace AHRI Reference SLP98UH070XV36B 9910935 XP16-024-230 24200 16 12.2 22200 13700 3.52 2.42 8.5 CX35-36A SL280UH070V36A 9910936 XP16-024-230 24200 16 12.2 22200 13700 3.52 2.42 8.5 CX35-36A SL280UH070XV36A 9910937 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 15.5 12.2 22200 13700 3.52 2.42 8.5 15 12.5 22000 13600 3.5 2.42 8.2 15.5 12.2 22200 13700 3.52 2.42 8.5 16 12.5 21600 13300 3.64 2.48 8.5 16 12.5 21600 13300 3.64 2.48 8.5 CX35-36B CX35-36B CX35-36B CX38-38A CX38-38A EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B SL280UH070V36A SL280UH070XV36A 9910938 9910939 9910940 10084921 10084928 XP16-024-230 24200 16 12.5 21600 13400 3.62 2.48 8.5 CX38-38B EL296UH070XV36B 10084927 XP16-024-230 24400 16 12.5 21800 13400 3.68 2.48 8.5 CX38-38B SL280UH090V36B 10084922 XP16-024-230 24000 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37200 16 12.5 21600 13300 3.6 2.46 8.5 16 13 32800 21600 3.1 2.56 8.5 15.5 12.5 33600 22200 3.02 2.46 8.5 16 12.5 33200 21800 3.08 2.52 8.5 16 13 33000 21800 3.1 2.56 8.5 CX38-38B C33-43 C33-43 C33-43 C33-43 SLP98UH070XV36B EL180UH070E36B EL195UH045XE36B EL195UH070XE36B EL195UH090XE48C 10084924 7785832 7785808 7785837 7785849 XP16-036-230 37000 15.5 12.5 33600 22200 3.02 2.46 8.5 C33-43 EL296UH045XE36B 7785848 XP16-036-230 37000 16 12.5 33200 21800 3.08 2.52 8.5 C33-43 EL296UH070XE36B 7785822 XP16-036-230 37200 16 XP16-036-230 37200 16 XP16-036-230 37200 16 XP16-036-230 37000 16 XP16-036-230 37800 16 12.5 33200 22000 3.06 2.52 8.5 13 33000 21800 3.1 2.56 8.5 13 33000 21800 3.12 2.56 8.5 13 33000 21600 3.1 2.54 8.5 13 33400 22000 3.18 2.58 8.5 C33-43 C33-43 C33-43 C33-43 C33-43 EL296UH070XV36B EL296UH090XE48C EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C 7785843 7785811 7785844 7785833 7785828 XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 C33-43 EL296UH110XV60C 7785803 XP16-036-230 37200 16 13 32800 21600 3.12 2.56 8.5 C33-43 SL280UH090V36B 7785827 XP16-036-230 37200 16 13 33000 21800 3.14 2.58 8.5 C33-43 SL280UH090V48B 7785802 XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 C33-43 XP16-036-230 37200 16 13 33000 21800 3.14 2.58 8.5 C33-43 XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 C33-43 XP16-036-230 37600 16 13 33200 21800 3.16 2.56 8.5 C33-43 XP16-036-230 37600 16 13 33200 21800 3.16 2.56 8.5 C33-43 SL280UH090V60C SL280UH090XV48B SL280UH090XV60C SL280UH110V60C SL280UH110XV60C 7785810 7785809 7785839 7785850 7785812 XP16-036-230 37200 16 12.5 33200 22000 3.06 2.52 8.5 C33-43 SLP98UH070XV36B 7785838 XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 C33-43 SLP98UH090XV36C 7785845 XP16-036-230 37000 XP16-036-230 37800 XP16-036-230 37600 XP16-036-230 36800 XP16-036-230 36800 16 13 16 13 16 13 14.5 12 14.5 12 33000 33400 33200 33600 33600 21600 22000 21800 22400 22400 3.1 2.54 8.5 3.18 2.58 8.5 3.18 2.58 8.5 2.96 2.42 8.2 2.96 2.42 8.2 C33-43 C33-43 C33-43 C33-43B C33-43C SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C 7785834 7785817 7785804 7785782 8444069 XP16-036-230 37400 16 13 34000 23000 2.88 2.4 8.2 C33-50/60C EL296UH090XV60C 7785794 XP16-036-230 37200 16 13 33600 22800 2.86 2.4 8.2 C33-50/60C EL296UH110XV60C 7785796 XP16-036-230 37400 16 13 33800 22800 2.88 2.4 8.2 C33-50/60C XP16-036-230 37400 16 13 33800 22800 2.88 2.4 8.2 C33-50/60C XP16-036-230 37400 16 13 34000 23000 2.88 2.4 8.2 C33-50/60C XP16-036-230 37200 16 13 33600 22800 2.86 2.4 8.2 C33-50/60C XP16-036-230 37000 16 13 32800 21600 3.1 2.56 8.5 C37-43B SL280UH090V60C SL280UH090XV60C SLP98UH090XV60C SLP98UH110XV60C EL180UH070E36B 7785797 7785798 7785795 7785789 10084970 XP16-036-230 37000 15.5 12.5 33600 22200 3.02 2.46 8.5 C37-43B EL195UH045XE36B 10084947 XP16-036-230 37000 16 12.5 33200 21800 3.08 2.52 8.5 C37-43B EL195UH070XE36B 10084975 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 11 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-036-230 37000 15.5 12.5 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 33600 22200 3.02 2.46 8.5 C37-43B Furnace AHRI Reference EL296UH045XE36B 10084985 XP16-036-230 37000 16 12.5 33200 21800 3.08 2.52 8.5 C37-43B EL296UH070XE36B 10084960 XP16-036-230 37200 16 12.5 33200 22000 3.06 2.52 8.5 C37-43B EL296UH070XV36B 10084980 XP16-036-230 37200 XP16-036-230 37200 XP16-036-230 37200 XP16-036-230 37200 XP16-036-230 36800 16 13 32800 21600 3.12 2.56 8.5 16 13 33000 21800 3.14 2.58 8.5 16 13 33000 21800 3.14 2.58 8.5 16 12.5 33200 22000 3.06 2.52 8.5 14.5 12 33600 22400 2.96 2.42 8.2 C37-43B C37-43B C37-43B C37-43B C37-43B SL280UH090V36B SL280UH090V48B SL280UH090XV48B SLP98UH070XV36B 10084965 10084941 10084948 10084976 10084111 XP16-036-230 37200 16 13 33000 21800 3.1 2.56 8.5 C37-43C EL195UH090XE48C 10084986 XP16-036-230 37200 16 13 33000 21800 3.1 2.56 8.5 C37-43C EL296UH090XE48C 10084950 XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 C37-43C XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 C37-43C XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 C37-43C XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 C37-43C XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 C37-43C EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C EL296UH110XV60C SL280UH090V60C 10084981 10084971 10084966 10084942 10084949 XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 C37-43C SL280UH090XV60C 10084977 XP16-036-230 37600 16 13 33200 21800 3.16 2.56 8.5 C37-43C SL280UH110V60C 10084987 XP16-036-230 37600 16 13 33200 21800 3.16 2.56 8.5 C37-43C XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 C37-43C XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 C37-43C XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 C37-43C XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 C37-43C SL280UH110XV60C SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C 10084951 10084982 10084972 10084956 10084943 XP16-036-230 36800 14.5 12 33600 22400 2.96 2.42 8.2 C37-43C 10084112 XP16-036-230 37400 16 13 34000 23000 2.88 2.4 8.2 C37-50/60C EL296UH090XV60C 10084933 XP16-036-230 37200 16 13 33600 22800 2.86 2.4 8.2 C37-50/60C EL296UH110XV60C 10084935 XP16-036-230 37400 16 XP16-036-230 37400 16 XP16-036-230 37400 16 XP16-036-230 37200 16 XP16-036-230 36000 16 13 33800 22800 2.88 2.4 8.2 13 33800 22800 2.88 2.4 8.2 13 34000 23000 2.88 2.4 8.2 13 33600 22800 2.86 2.4 8.2 12.5 35400 23000 3.46 2.66 9 C37-50/60C C37-50/60C C37-50/60C C37-50/60C CBA27UHE-042 SL280UH090V60C SL280UH090XV60C SLP98UH090XV60C SLP98UH110XV60C 10084936 10084937 10084934 10084931 10258587 XP16-036-230 36200 14.5 12 36800 24400 2.8 2.68 8.2 CBX25UH-036 7785904 XP16-036-230 36200 16 12.5 34600 23200 3.18 2.58 8.5 CBX25UHV-036 7785792 XP16-036-230 36200 XP16-036-230 37600 XP16-036-230 35600 XP16-036-230 36400 XP16-036-230 37600 15.5 12.5 34400 23000 3.2 2.6 9 16 13 34200 23400 3.36 2.84 9.5 14.5 12 34800 23400 3.12 2.52 8.7 16.5 12.5 34600 23200 3.2 2.6 9 16 13 34200 23400 3.36 2.84 9.5 CBX27UH-036 CBX27UH-042 CBX32M-036 CBX32MV-036 CBX32MV-048 7785786 7785903 7785785 7785784 7785901 XP16-036-230 36200 16 13 34400 23000 3.22 2.62 9 CBX40UHV-030 7785788 XP16-036-230 36200 16 12.5 34600 23200 3.22 2.6 9 CBX40UHV-036 7785787 XP16-036-230 37400 XP16-036-230 37400 XP16-036-230 38000 XP16-036-230 38000 XP16-036-230 37600 16 13.5 34400 23000 3.24 2.62 9 16 13.5 34400 22800 3.26 2.64 8.5 16 13 33000 22200 3.38 2.6 8.5 16 13 33000 22200 3.44 2.64 9 15.5 12.5 33200 22400 3.3 2.54 8.5 CBX40UHV-042 CBX40UHV-048 CH33-43B CH33-43B CH33-43B EL180UH070E36B EL180UH090E48B EL195UH045XE36B 7785902 7785783 7785898 7785896 7785884 XP16-036-230 37800 15.5 12.5 33000 22400 3.3 2.56 8.5 CH33-43B EL195UH070XE36B 7785889 XP16-036-230 37600 15.5 12.5 33200 22400 3.3 2.54 8.5 CH33-43B EL296UH045XE36B 7785892 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 12 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-036-230 37800 16 12.5 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 33000 22400 3.34 2.58 8.5 CH33-43B Furnace AHRI Reference EL296UH045XV36B 7785905 XP16-036-230 37800 15.5 12.5 33000 22400 3.3 2.56 8.5 CH33-43B EL296UH070XE36B 7785894 XP16-036-230 37800 16 12.5 33000 22200 3.36 2.58 8.5 CH33-43B EL296UH070XV36B 7785906 XP16-036-230 37800 XP16-036-230 38000 XP16-036-230 38000 XP16-036-230 37800 XP16-036-230 37400 16 13 32600 22000 3.4 2.64 8.5 16 13 32800 22000 3.4 2.62 8.5 16 13 32800 22000 3.4 2.62 8.5 16 12.5 33000 22200 3.36 2.58 8.5 14.5 12 33200 22600 3.22 2.5 8.5 CH33-43B CH33-43B CH33-43B CH33-43B CH33-43B SL280UH090V36B SL280UH090V48B SL280UH090XV48B SLP98UH070XV36B 7785897 7785895 7785891 7785899 7785777 XP16-036-230 37400 16 13 33000 21800 3.16 2.58 8.5 CH33-43C EL195UH090XE48C 7785900 XP16-036-230 37400 16 13 33000 21800 3.16 2.58 8.5 CH33-43C EL296UH090XE48C 7785885 XP16-036-230 37400 16 13 32400 21800 3.32 2.56 8.5 CH33-43C XP16-036-230 37200 16 13 32400 21800 3.32 2.58 8.5 CH33-43C XP16-036-230 38000 16 13 32800 22000 3.36 2.58 8.5 CH33-43C XP16-036-230 37800 16 13 32600 22000 3.36 2.6 8.5 CH33-43C XP16-036-230 38000 16 13 32800 22000 3.36 2.58 8.5 CH33-43C EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C EL296UH110XV60C SL280UH090V60C 7785890 7785893 7785790 7785791 7785883 XP16-036-230 38000 16 13 32600 22000 3.38 2.62 8.5 CH33-43C SL280UH090XV60C 7785888 XP16-036-230 37800 16 13 32600 22000 3.36 2.6 8.5 CH33-43C SL280UH110V60C 7785880 XP16-036-230 37800 16 13 32600 22000 3.34 2.58 8.5 CH33-43C XP16-036-230 37400 16 13 32400 21800 3.32 2.56 8.5 CH33-43C XP16-036-230 37200 16 13 32400 21800 3.32 2.58 8.5 CH33-43C XP16-036-230 38000 16 13 32800 22000 3.36 2.58 8.5 CH33-43C XP16-036-230 37800 16 13 32600 22000 3.36 2.6 8.5 CH33-43C SL280UH110XV60C SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C 7785868 7785872 7785853 7785876 7785860 XP16-036-230 36800 14.5 12 33600 22400 3.02 2.44 8.2 CH33-43C 7785779 XP16-036-230 37000 16 13 33000 21800 3.16 2.54 8.5 CH33-48C EL195UH090XE48C 7785855 XP16-036-230 37000 16 13 33000 21800 3.16 2.54 8.5 CH33-48C EL296UH090XE48C 7785866 XP16-036-230 37000 16 13 33000 21800 3.16 2.54 8.5 CH33-48C XP16-036-230 36800 16 13 32800 21800 3.14 2.56 8.5 CH33-48C XP16-036-230 37600 16 13 33200 22000 3.2 2.56 8.5 CH33-48C XP16-036-230 37400 16 13 33000 21800 3.2 2.56 8.5 CH33-48C XP16-036-230 37600 16 13 33200 22000 3.24 2.6 8.5 CH33-48C EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C EL296UH110XV60C SL280UH090V60C 7785881 7785877 7785869 7785873 7785854 XP16-036-230 37600 16 13 33200 22000 3.24 2.6 8.5 CH33-48C SL280UH090XV60C 7785865 XP16-036-230 37200 16 13 33200 22000 3.2 2.56 8.5 CH33-48C SL280UH110V60C 7785861 XP16-036-230 37200 16 13 33200 22000 3.2 2.56 8.5 CH33-48C XP16-036-230 37000 16 13 33000 21800 3.16 2.54 8.5 CH33-48C XP16-036-230 36800 16 13 32800 21800 3.14 2.56 8.5 CH33-48C XP16-036-230 37600 16 13 33200 22000 3.2 2.56 8.5 CH33-48C XP16-036-230 37400 16 13 33000 21800 3.2 2.56 8.5 CH33-48C SL280UH110XV60C SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C 7785863 7785882 7785878 7785870 7785874 XP16-036-230 36400 14.5 12 33600 22400 3 2.42 8.2 CH33-48C 7785780 XP16-036-230 36400 16 13 35800 22400 3 2.68 8.5 CR33-48B EL180DF070E36B 7785859 XP16-036-230 36600 XP16-036-230 36400 XP16-036-230 36600 XP16-036-230 36400 XP16-036-230 36000 15.5 12 36400 23000 2.96 2.6 8.5 15.5 12.5 36000 22600 3 2.64 8.7 15.5 12 36400 23000 2.96 2.6 8.5 15.5 12.5 36000 22600 3 2.64 8.7 15 12.5 36000 22800 2.96 2.62 8.5 CR33-48B CR33-48B CR33-48B CR33-48B CR33-48B EL195DF045XE36B EL195DF070XE48B EL296DF045XE36B EL296DF070XE48B EL296DF070XV48B 7785862 7785864 7785871 7785879 8203819 XP16-036-230 36600 16 12.5 36000 22600 3.02 2.66 8.5 CR33-48B SL280DF090V48B 7785875 XP16-036-230 36200 16 12.5 36000 22600 2.98 2.64 8.5 CR33-48B SLP98DF070XV36B 7785887 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 13 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-036-230 36000 14 11.5 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 36600 23200 2.88 2.54 8.2 CR33-48B Furnace AHRI Reference 7785778 XP16-036-230 37200 16 13 36000 22600 3.08 2.72 8.5 CR33-48C SL280DF090V60C 7785856 XP16-036-230 36800 16 13 36000 22600 3.06 2.72 8.5 CR33-48C SL280DF110V60C 7785867 XP16-036-230 36600 16 XP16-036-230 36600 16 XP16-036-230 36800 16 XP16-036-230 36800 16 XP16-036-230 37000 16 12.5 36000 22600 3 2.66 8.5 12.5 36000 22600 3.02 2.68 8.5 12.5 36200 22600 3.06 2.68 8.5 12.5 36200 22800 3.06 2.7 8.5 13 32800 21600 3.1 2.56 8.5 CR33-48C CR33-48C CR33-48C CR33-48C CX34-43 SLP98DF090XV36C SLP98DF090XV48C SLP98DF090XV60C SLP98DF110XV60C EL180UH070E36B 7785886 7785818 7785851 7785840 7785852 XP16-036-230 37000 15.5 12.5 33600 22200 3.02 2.46 8.5 CX34-43 EL195UH045XE36B 7785813 XP16-036-230 37000 16 12.5 33200 21800 3.08 2.52 8.5 CX34-43 EL195UH070XE36B 7785823 XP16-036-230 37200 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37200 XP16-036-230 37200 16 13 33000 21800 3.1 2.56 8.5 15.5 12.5 33600 22200 3.02 2.46 8.5 16 12.5 33200 21800 3.08 2.52 8.5 16 12.5 33200 22000 3.06 2.52 8.5 16 13 33000 21800 3.1 2.56 8.5 CX34-43 CX34-43 CX34-43 CX34-43 CX34-43 EL195UH090XE48C EL296UH045XE36B EL296UH070XE36B EL296UH070XV36B EL296UH090XE48C 7785835 7785846 7785857 7785819 7785858 XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 CX34-43 EL296UH090XV36C 7785820 XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 CX34-43 EL296UH090XV48C 7785841 XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 CX34-43 XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 CX34-43 XP16-036-230 37200 16 13 32800 21600 3.12 2.56 8.5 CX34-43 XP16-036-230 37200 16 13 33000 21800 3.12 2.58 8.5 CX34-43 XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 CX34-43 EL296UH090XV60C EL296UH110XV60C SL280UH090V36B SL280UH090V48B SL280UH090V60C 7785830 7785825 7785829 7785824 7785801 XP16-036-230 37200 16 13 33000 21800 3.12 2.58 8.5 CX34-43 SL280UH090XV48B 7785800 XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 CX34-43 SL280UH090XV60C 7785807 XP16-036-230 37400 16 13 33200 21800 3.14 2.56 8.5 CX34-43 SL280UH110V60C 7785836 XP16-036-230 37400 16 XP16-036-230 37200 16 XP16-036-230 37200 16 XP16-036-230 37000 16 XP16-036-230 37800 16 13 33200 21800 3.14 2.56 8.5 12.5 33200 22000 3.06 2.52 8.5 13 33000 21800 3.12 2.56 8.5 13 33000 21600 3.1 2.54 8.5 13 33400 22000 3.18 2.58 8.5 CX34-43 CX34-43 CX34-43 CX34-43 CX34-43 SL280UH110XV60C SLP98UH070XV36B SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C 7785847 7785806 7785821 7785842 7785831 XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 CX34-43 SLP98UH110XV60C 7785826 XP16-036-230 36800 14.5 12 33600 22400 2.96 2.42 8.2 CX34-43 7785781 XP16-036-230 37400 XP16-036-230 37200 XP16-036-230 37400 XP16-036-230 37400 XP16-036-230 37400 16 13 16 13 16 13 16.5 13 16 13 34000 23000 2.88 2.4 8.2 33600 22800 2.86 2.4 8.2 33800 22800 2.88 2.4 8.2 33800 22800 2.88 2.4 8.2 34000 23000 2.88 2.4 8.2 CX34-50/60C CX34-50/60C CX34-50/60C CX34-50/60C CX34-50/60C EL296UH090XV60C EL296UH110XV60C SL280UH090V60C SL280UH090XV60C SLP98UH090XV60C 7785814 7785816 7785793 7785799 7785815 XP16-036-230 37400 16 13 33600 22800 2.86 2.4 8.2 CX34-50/60C SLP98UH110XV60C 7785805 XP16-036-230 37000 16 13 32800 21600 3.1 2.56 8.5 CX38-43B EL180UH070E36B 10084988 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37200 15.5 12.5 33600 22200 3.02 2.46 8.5 16 12.5 33200 21800 3.08 2.52 8.5 15.5 12.5 33600 22200 3.02 2.46 8.5 16 12.5 33200 21800 3.08 2.52 8.5 16 12.5 33200 22000 3.06 2.52 8.5 CX38-43B CX38-43B CX38-43B CX38-43B CX38-43B EL195UH045XE36B EL195UH070XE36B EL296UH045XE36B EL296UH070XE36B EL296UH070XV36B 10084952 10084961 10084983 10084989 10084957 XP16-036-230 37200 16 13 32800 21600 3.12 2.56 8.5 CX38-43B SL280UH090V36B 10084967 XP16-036-230 37200 16 13 33000 21800 3.12 2.58 8.5 CX38-43B SL280UH090V48B 10084962 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 14 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-036-230 37200 16 13 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 33000 21800 3.12 2.58 8.5 CX38-43B Furnace AHRI Reference SL280UH090XV48B 10084939 XP16-036-230 37200 16 12.5 33200 22000 3.06 2.52 8.5 CX38-43B SLP98UH070XV36B 10084945 XP16-036-230 36800 14.5 12 33600 22400 2.96 2.42 8.2 CX38-43B 10086664 XP16-036-230 37200 16 13 33000 21800 3.1 2.56 8.5 CX38-43C XP16-036-230 37200 16 13 33000 21800 3.1 2.56 8.5 CX38-43C XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 CX38-43C XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 CX38-43C XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 CX38-43C EL195UH090XE48C EL296UH090XE48C EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C 10084973 10084990 10084958 10084978 10084968 XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 CX38-43C EL296UH110XV60C 10084963 XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 CX38-43C SL280UH090V60C 10084940 XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 CX38-43C XP16-036-230 37400 16 13 33200 21800 3.14 2.56 8.5 CX38-43C XP16-036-230 37400 16 13 33200 21800 3.14 2.56 8.5 CX38-43C XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 CX38-43C XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 CX38-43C SL280UH090XV60C SL280UH110V60C SL280UH110XV60C SLP98UH090XV36C SLP98UH090XV48C 10084946 10084974 10084984 10084959 10084979 XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 CX38-43C SLP98UH090XV60C 10084969 XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 CX38-43C SLP98UH110XV60C 10084964 XP16-036-230 36800 XP16-036-230 37400 XP16-036-230 37200 XP16-036-230 37400 XP16-036-230 37400 14.5 12 16 13 16 13 16 13 16.5 13 33600 34000 33600 33800 33800 22400 23000 22800 22800 22800 2.96 2.42 8.2 2.88 2.4 8.2 2.86 2.4 8.2 2.88 2.4 8.2 2.88 2.4 8.2 CX38-43C CX38-50/60C CX38-50/60C CX38-50/60C CX38-50/60C EL296UH090XV60C EL296UH110XV60C SL280UH090V60C SL280UH090XV60C 10086665 10084953 10084955 10084932 10084938 XP16-036-230 37400 16 13 34000 23000 2.88 2.4 8.2 CX38-50/60C SLP98UH090XV60C 10084954 XP16-036-230 37400 16 13 33600 22800 2.86 2.4 8.2 CX38-50/60C SLP98UH110XV60C 10084944 XP16-048-230 47000 15.5 12 41500 28000 3.46 2.58 9 C33-62C EL180UH090E60C 7785931 XP16-048-230 47500 15 XP16-048-230 47000 15 XP16-048-230 47000 15 XP16-048-230 47000 15 XP16-048-230 47000 15 11.5 42000 28600 3.44 2.56 9 12 41500 28200 3.4 2.54 8.7 12 41500 28200 3.44 2.56 9 12 41500 28200 3.4 2.54 8.7 12 41500 28200 3.44 2.56 9 C33-62C C33-62C C33-62C C33-62C C33-62C EL180UH110E60C EL195UH090XE48C EL195UH110XE60C EL296UH090XE48C EL296UH110XE60C 7785924 7785914 7785917 7785915 7785918 XP16-048-230 46500 15 11.5 42000 28000 3.22 2.36 8.2 C35-49C EL180UH090E60C 9910856 XP16-048-230 47000 15 11.5 42500 28600 3.22 2.36 8.2 C35-49C EL180UH110E60C 9910857 XP16-048-230 46500 15 XP16-048-230 46500 15 XP16-048-230 46500 15 XP16-048-230 46500 15 XP16-048-230 46500 15 11.5 42000 28000 3.2 2.34 8.2 11.5 42500 28400 3.2 2.34 8.2 11.5 42500 28400 3.2 2.34 8.2 11.5 42000 28000 3.2 2.34 8.2 11.5 42000 28200 3.18 2.36 8.2 C35-49C C35-49C C35-49C C35-49C C35-49C EL195UH110XE60C EL296UH090XV48C EL296UH090XV60C EL296UH110XE60C EL296UH110XV48C 9910858 9910859 9910860 9910862 9910861 XP16-048-230 46500 15 11.5 42500 28200 3.22 2.34 8.2 C35-49C EL296UH110XV60C 9910863 XP16-048-230 46500 15.5 11.5 42000 28000 3.22 2.36 8.2 C35-49C SL280UH090V60C 9910864 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 47000 15.5 11.5 42000 28000 3.22 2.36 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2 15 11.5 42000 28200 3.18 2.34 8.2 15.5 12 43000 26000 3.52 2.32 8.2 C35-49C C35-49C C35-49C C35-49C C35-60C SL280UH090XV60C SL280UH110V60C SL280UH110XV60C SLP98UH090XV48C EL180UH090E60C 9910865 9910866 9910867 9910868 9910869 XP16-048-230 47500 15.5 11.5 44000 26600 3.54 2.32 8.2 C35-60C EL180UH110E60C 9910870 XP16-048-230 46500 15 11.5 43500 26200 3.5 2.3 8.2 C35-60C EL195UH090XE48C 9910871 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 15 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-048-230 47000 15.5 11.5 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 43500 26000 3.52 2.3 8.2 C35-60C Furnace AHRI Reference EL195UH110XE60C 9910872 XP16-048-230 46500 15 11.5 43500 26200 3.5 2.3 8.2 C35-60C EL296UH090XE48C 9910873 XP16-048-230 47000 15.5 11.5 44000 26400 3.52 2.28 8.2 C35-60C EL296UH090XV48C 9910874 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 15.5 11.5 44000 26400 3.52 2.28 8.2 15.5 11.5 43500 26000 3.52 2.3 8.2 15.5 11.5 43500 26200 3.52 2.3 8.2 15.5 11.5 43500 26200 3.5 2.28 8.2 15.5 11.5 43500 26000 3.54 2.32 8.2 C35-60C C35-60C C35-60C C35-60C C35-60C EL296UH090XV60C EL296UH110XE60C EL296UH110XV48C EL296UH110XV60C SL280UH090V60C 9910875 9910877 9910876 9910878 9910879 XP16-048-230 47000 15.5 11.5 43500 26000 3.54 2.32 8.2 C35-60C SL280UH090XV60C 9910880 XP16-048-230 47000 15.5 11.5 43500 26000 3.54 2.32 8.2 C35-60C SL280UH110V60C 9910881 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47500 15.5 11.5 43500 26000 3.54 2.32 8.2 15.5 11.5 43500 26200 3.5 2.3 8.2 15.5 11.5 43500 26200 3.5 2.3 8.2 15.5 11.5 43500 26200 3.5 2.28 8.2 15.5 12 43000 28200 3.24 2.36 8.2 C35-60C C35-60C C35-60C C35-60C C35-60D SL280UH110XV60C SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C SL280UH135V60D 9910882 9910883 9910884 9910885 9910886 XP16-048-230 48000 15.5 12 43000 28400 3.24 2.36 8.2 C35-60D SLP98UH135XV60D 9910887 XP16-048-230 47000 15.5 12 41500 28000 3.46 2.58 9 C37-62C EL180UH090E60C 10084996 XP16-048-230 47500 15 XP16-048-230 47000 15 XP16-048-230 47000 15 XP16-048-230 47000 15 XP16-048-230 47000 15 11.5 42000 28600 3.44 2.56 9 12 41500 28200 3.4 2.54 8.7 12 41500 28200 3.44 2.56 9 12 41500 28200 3.4 2.54 8.7 12 41500 28200 3.44 2.56 9 C37-62C C37-62C C37-62C C37-62C C37-62C EL180UH110E60C EL195UH090XE48C EL195UH110XE60C EL296UH090XE48C EL296UH110XE60C 10084995 10084991 10084993 10084992 10084994 XP16-048-230 47500 16 12 45000 30000 3.44 2.62 9 CBA27UHE-048 10258588 XP16-048-230 47000 15 11.5 44500 27400 3.58 2.68 9 CBA27UHE-060 10258974 XP16-048-230 47500 15 12 44000 29400 3.48 2.56 8.5 CBX25UHV-048 7785919 XP16-048-230 48500 XP16-048-230 47500 XP16-048-230 48000 XP16-048-230 48000 XP16-048-230 48500 16 12.5 45000 29800 3.4 2.64 9 15.5 11.5 44500 27200 3.58 2.54 9 15.5 12 45500 30200 3.32 2.58 8.7 16 12.5 45500 30000 3.38 2.62 8.5 16 12.5 45000 30800 3.56 2.72 9.5 CBX27UH-048 CBX27UH-060 CBX32M-048 CBX32MV-048 CBX32MV-060 7785916 7785972 7785973 7785968 7785913 XP16-048-230 48000 16 12.5 41000 26600 3.36 2.46 8.5 CBX32MV-068 7785962 XP16-048-230 48000 16 12.5 45500 30000 3.38 2.6 8.5 CBX40UHV-048 7785969 XP16-048-230 48500 16 XP16-048-230 48500 16 XP16-048-230 48500 16 XP16-048-230 48500 16 XP16-048-230 48500 16 12.5 45000 31000 3.6 2.76 9.5 12.5 45000 29200 3.62 2.62 9 12.5 45000 29200 3.6 2.62 9 12 45000 29400 3.56 2.58 8.5 12 45000 29400 3.58 2.6 9 CBX40UHV-060 CH23-68 CH23-68 CH23-68 CH23-68 EL180UH090E60C EL180UH110E60C EL195UH090XE48C EL195UH110XE60C 7785970 7785921 7785923 7785971 7785950 XP16-048-230 48500 16 12 45000 29400 3.56 2.58 8.5 CH23-68 EL296UH090XE48C 7785951 XP16-048-230 48500 16 12 45000 29400 3.58 2.6 9 CH23-68 EL296UH110XE60C 7785963 XP16-048-230 48500 XP16-048-230 48500 XP16-048-230 48500 XP16-048-230 48000 XP16-048-230 48000 16 12 45000 29400 3.62 2.62 9 16 12 45000 29200 3.6 2.6 9 16 12 45500 29400 3.62 2.6 9 14.5 11.5 45500 30000 3.44 2.52 8.5 15 12 45500 31600 3.26 2.64 8.7 CH23-68 CH23-68 CH23-68 CH23-68 CH33-60D EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D EL296UH135XV60D 7785959 7785965 7785956 7785907 7785966 XP16-048-230 48000 15 12 45000 31400 3.22 2.64 8.7 CH33-60D SL280UH135V60D 7785957 XP16-048-230 48500 15 12 45500 31600 3.26 2.64 8.7 CH33-60D SLP98UH135XV60D 7785960 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 16 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-048-230 47000 15 12 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 43500 28600 3.38 2.48 8.7 CH33-62D Furnace AHRI Reference EL296UH135XV60D 7785952 XP16-048-230 46500 15 12 43500 28600 3.4 2.5 8.7 CH33-62D SL280UH135V60D 7785964 XP16-048-230 47000 15 12 43500 28800 3.38 2.5 8.7 CH33-62D SLP98UH135XV60D 7785953 XP16-048-230 48000 XP16-048-230 48000 XP16-048-230 48000 XP16-048-230 47500 XP16-048-230 48000 15.5 11.5 43500 29600 3.12 2.34 8.2 15.5 11.5 43500 29600 3.1 2.32 8.2 15 11.5 43500 29600 3.1 2.32 8.2 15.5 11.5 43000 29200 3.04 2.28 8.2 15 11.5 43500 29600 3.1 2.32 8.2 CH35-51C CH35-51C CH35-51C CH35-51C CH35-51C EL180UH090E60C EL180UH110E60C EL195UH110XE60C EL296UH090XE48C EL296UH110XE60C 9910888 9910889 9910890 9910891 9910893 XP16-048-230 47500 15.5 11.5 43000 29200 3.06 2.3 8.2 CH35-51C EL296UH110XV60C 9910894 XP16-048-230 47500 15.5 12 43000 29000 3.1 2.3 8.2 CH35-51C SL280UH090V60C 9910895 XP16-048-230 47500 XP16-048-230 47500 XP16-048-230 47500 XP16-048-230 47500 XP16-048-230 47000 15.5 12 43000 29000 3.1 2.3 8.2 15.5 11.5 43000 29200 3.04 2.28 8.2 15.5 11.5 43000 29200 3.06 2.3 8.2 16 12.5 44000 30200 3.54 2.7 9.5 15.5 12 44500 30400 3.48 2.64 9.2 CH35-51C CH35-51C CH35-51C CR33-50/60 CR33-50/60 SL280UH090XV60C SLP98UH090XV48C SLP98UH110XV60C EL180DF110E60C EL195DF090XE48C 9910896 9910897 9910898 7785925 7785967 XP16-048-230 47000 16 12 44000 30200 3.5 2.68 9 CR33-50/60 EL195DF110XE60C 7785958 XP16-048-230 47000 15.5 12 44500 30400 3.48 2.64 9.2 CR33-50/60 EL296DF090XE48C 7785961 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 16 12 16 12 16 12 16 12 14.5 11.5 44000 44500 44500 44500 44500 30200 30600 30400 30600 30800 3.5 2.68 9 3.48 2.64 9 3.48 2.64 9 3.48 2.64 9 3.38 2.6 9 CR33-50/60 CR33-50/60 CR33-50/60 CR33-50/60 CR33-50/60 EL296DF110XE60C EL296DF110XV60C SLP98DF090XV60C SLP98DF110XV60C 7785933 8688153 7785948 7785928 7785908 XP16-048-230 47000 16 12 44500 30400 3.48 2.64 9 CR33-60 SLP98DF090XV60C 7785944 XP16-048-230 47000 16 12 44500 30400 3.48 2.62 9 CR33-60 SLP98DF110XV60C 7785938 XP16-048-230 47000 14.5 11.5 44500 30600 3.38 2.58 9 CR33-60 7785909 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46000 XP16-048-230 47000 XP16-048-230 47500 15.5 11.5 43000 28800 3.34 2.5 8.5 16 11.5 43500 29000 3.36 2.5 8.5 14 11 43500 29400 3.22 2.42 8.2 15.5 12 41500 28000 3.46 2.58 9 15 11.5 42000 28600 3.44 2.56 9 CX34-60D CX34-60D CX34-60D CX34-62C CX34-62C SL280UH135V60D SLP98UH135XV60D EL180UH090E60C EL180UH110E60C 7785934 7785937 7785912 7785920 7785922 XP16-048-230 47000 15 12 41500 28200 3.4 2.54 8.7 CX34-62C EL195UH090XE48C 7785929 XP16-048-230 47000 15 12 41500 28200 3.44 2.56 9 CX34-62C EL195UH110XE60C 7785954 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 15 12 41500 28200 3.4 2.54 8.7 15.5 11.5 42000 28400 3.42 2.54 8.7 15.5 11.5 42000 28400 3.42 2.54 8.7 15 12 41500 28200 3.44 2.56 9 15.5 12 41500 28200 3.42 2.56 8.7 CX34-62C CX34-62C CX34-62C CX34-62C CX34-62C EL296UH090XE48C EL296UH090XV48C EL296UH090XV60C EL296UH110XE60C EL296UH110XV48C 7785945 7785942 7785935 7785939 7785926 XP16-048-230 47000 15.5 11.5 42000 28400 3.44 2.54 8.7 CX34-62C EL296UH110XV60C 7785949 XP16-048-230 47000 15.5 12 41500 28200 3.46 2.58 9 CX34-62C SL280UH090V60C 7785930 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 11.5 42000 28200 3.44 2.54 8.7 15 11.5 42000 28200 3.46 2.54 8.7 CX34-62C CX34-62C CX34-62C CX34-62C CX34-62C SL280UH090XV60C SL280UH110V60C SL280UH110XV60C SLP98UH090XV48C SLP98UH090XV60C 7785955 7785946 7785940 7785943 7785936 XP16-048-230 47000 15.5 11.5 42000 28400 3.44 2.54 8.7 CX34-62C SLP98UH110XV60C 7785927 XP16-048-230 46500 14 11 42000 28800 3.32 2.5 8.5 CX34-62C 7785911 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 17 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-048-230 48500 16 12 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 43000 27600 3.42 2.44 8.5 CX34-62D Furnace AHRI Reference EL296UH135XV60D 7785947 XP16-048-230 48000 16 12 42500 27600 3.4 2.46 8.5 CX34-62D SL280UH135V60D 7785941 XP16-048-230 48500 16 12 43000 27800 3.44 2.46 8.5 CX34-62D SLP98UH135XV60D 7785932 XP16-048-230 48000 15 XP16-048-230 46500 15 XP16-048-230 47000 15 XP16-048-230 46500 15 XP16-048-230 46500 15 11.5 43000 28200 3.28 2.4 8.2 11.5 42000 28000 3.22 2.36 8.2 11.5 42500 28600 3.22 2.36 8.2 11.5 42000 28000 3.2 2.34 8.2 11.5 42500 28400 3.2 2.34 8.2 CX34-62D CX35-49C CX35-49C CX35-49C CX35-49C EL180UH090E60C EL180UH110E60C EL195UH110XE60C EL296UH090XV48C 7785910 9910899 9910900 9910901 9910902 XP16-048-230 46500 15 11.5 42500 28400 3.2 2.34 8.2 CX35-49C EL296UH090XV60C 9910903 XP16-048-230 46500 15 11.5 42000 28000 3.2 2.34 8.2 CX35-49C EL296UH110XE60C 9910905 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500 15 11.5 42000 28200 3.18 2.36 8.2 15 11.5 42500 28200 3.22 2.34 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2 CX35-49C CX35-49C CX35-49C CX35-49C CX35-49C EL296UH110XV48C EL296UH110XV60C SL280UH090V60C SL280UH090XV60C SL280UH110V60C 9910904 9910906 9910907 9910908 9910909 XP16-048-230 46500 15.5 11.5 42000 28000 3.22 2.36 8.2 CX35-49C SL280UH110XV60C 9910910 XP16-048-230 46500 15 11.5 42000 28200 3.18 2.34 8.2 CX35-49C SLP98UH090XV48C 9910911 XP16-048-230 47000 XP16-048-230 47500 XP16-048-230 46500 XP16-048-230 47000 XP16-048-230 46500 15.5 12 43000 26000 3.52 2.32 8.2 15.5 11.5 44000 26600 3.54 2.32 8.2 15 11.5 43500 26200 3.5 2.3 8.2 15.5 11.5 43500 26000 3.52 2.3 8.2 15 11.5 43500 26200 3.5 2.3 8.2 CX35-60C CX35-60C CX35-60C CX35-60C CX35-60C EL180UH090E60C EL180UH110E60C EL195UH090XE48C EL195UH110XE60C EL296UH090XE48C 9910912 9910913 9910914 9910915 9910916 XP16-048-230 47000 15.5 11.5 44000 26400 3.52 2.28 8.2 CX35-60C EL296UH090XV48C 9910917 XP16-048-230 47000 15.5 11.5 44000 26400 3.52 2.28 8.2 CX35-60C EL296UH090XV60C 9910918 XP16-048-230 47000 15.5 11.5 43500 26000 3.52 2.3 8.2 CX35-60C EL296UH110XE60C 9910920 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 15.5 11.5 43500 26200 3.52 2.3 8.2 15.5 11.5 43500 26200 3.5 2.28 8.2 15.5 11.5 43500 26000 3.54 2.32 8.2 15.5 11.5 43500 26000 3.54 2.32 8.2 15.5 11.5 43500 26000 3.54 2.32 8.2 CX35-60C CX35-60C CX35-60C CX35-60C CX35-60C EL296UH110XV48C EL296UH110XV60C SL280UH090V60C SL280UH090XV60C SL280UH110V60C 9910919 9910921 9910922 9910923 9910924 XP16-048-230 47000 15.5 11.5 43500 26000 3.54 2.32 8.2 CX35-60C SL280UH110XV60C 9910925 XP16-048-230 47000 15.5 11.5 43500 26200 3.5 2.3 8.2 CX35-60C SLP98UH090XV48C 9910926 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47500 XP16-048-230 48000 XP16-048-230 46500 15.5 11.5 43500 26200 3.5 2.3 8.2 15.5 11.5 43500 26200 3.5 2.28 8.2 15.5 12 43000 28200 3.24 2.36 8.2 15.5 12 43000 28400 3.24 2.36 8.2 15.5 11.5 43000 28800 3.34 2.5 8.5 CX35-60C CX35-60C CX35-60D CX35-60D CX38-60D SLP98UH090XV60C SLP98UH110XV60C SL280UH135V60D SLP98UH135XV60D SL280UH135V60D 9910927 9910928 9910929 9910930 10086733 XP16-048-230 46500 16 11.5 43500 29000 3.36 2.5 8.5 CX38-60D SLP98UH135XV60D 10086735 XP16-048-230 46000 14 11 43500 29400 3.22 2.42 8.2 CX38-60D 10086667 XP16-048-230 47000 XP16-048-230 47500 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 15.5 12 41500 28000 3.46 2.58 9 15 11.5 42000 28600 3.44 2.56 9 15 12 41500 28200 3.4 2.54 8.7 15 12 41500 28200 3.44 2.56 9 15 12 41500 28200 3.4 2.54 8.7 CX38-62C CX38-62C CX38-62C CX38-62C CX38-62C EL180UH090E60C EL180UH110E60C EL195UH090XE48C EL195UH110XE60C EL296UH090XE48C 10086727 10086728 10086731 10086743 10086740 XP16-048-230 47000 15.5 11.5 42000 28400 3.42 2.54 8.7 CX38-62C EL296UH090XV48C 10086738 XP16-048-230 47000 15.5 11.5 42000 28400 3.42 2.54 8.7 CX38-62C EL296UH090XV60C 10086902 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 18 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-048-230 47000 15 12 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 41500 28200 3.44 2.56 9 CX38-62C Furnace AHRI Reference EL296UH110XE60C 10086736 XP16-048-230 47000 15.5 12 41500 28200 3.42 2.56 8.7 CX38-62C EL296UH110XV48C 10086729 XP16-048-230 47000 15.5 11.5 42000 28400 3.44 2.54 8.7 CX38-62C EL296UH110XV60C 10086742 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 11.5 42000 28200 3.44 2.54 8.7 CX38-62C CX38-62C CX38-62C CX38-62C CX38-62C SL280UH090V60C SL280UH090XV60C SL280UH110V60C SL280UH110XV60C SLP98UH090XV48C 10086732 10086744 10086741 10086737 10086739 XP16-048-230 47000 15 11.5 42000 28200 3.46 2.54 8.7 CX38-62C SLP98UH090XV60C 10086734 XP16-048-230 47000 15.5 11.5 42000 28400 3.44 2.54 8.7 CX38-62C SLP98UH110XV60C 10086730 XP16-048-230 46500 14 XP16-048-230 48500 16 XP16-048-230 48000 16 XP16-048-230 48500 16 XP16-048-230 48000 15 11 42000 28800 3.32 2.5 8.5 12 43000 27600 3.42 2.44 8.5 12 42500 27600 3.4 2.46 8.5 12 43000 27800 3.44 2.46 8.5 11.5 43000 28200 3.28 2.4 8.2 CX38-62C CX38-62D CX38-62D CX38-62D CX38-62D EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D 10086666 10084999 10084998 10084997 10084113 XP16-060-230 58500 15.7 12.2 53000 34800 3.22 2.38 8.5 C33-62D EL180UH135E60D 7785992 XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 C33-62D EL195UH135XE60D 7785987 XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 57000 15.2 11.5 53000 35200 3.18 2.36 8.2 15.7 12 53000 34800 3.22 2.38 8.5 15.7 12 53000 35000 3.2 2.38 8.5 15.7 12 53000 34800 3.22 2.38 8.5 14.5 11.5 53000 35000 3.16 2.36 8.2 C33-62D C33-62D C33-62D C33-62D C33-62D EL296UH135XE60D EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D 7785985 7785990 7785994 7786000 7785977 XP16-060-230 58500 15.7 12.2 53000 34800 3.22 2.38 8.5 C37-62D EL180UH135E60D 10085007 XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 C37-62D EL195UH135XE60D 10085003 XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 C37-62D EL296UH135XE60D 10085001 XP16-060-230 58500 XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 57000 XP16-060-230 57000 15.7 12 15.7 12 15.7 12 14.5 11.5 14.5 11.5 53000 53000 53000 53000 56000 34800 35000 34800 35000 34400 3.22 2.38 8.5 3.2 2.38 8.5 3.22 2.38 8.5 3.16 2.36 8.2 3.44 2.48 8.5 C37-62D C37-62D C37-62D C37-62D CBA27UHE-060 EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D 10085005 10085009 10085011 10084115 10258975 XP16-060-230 57000 15 11.5 53500 35400 3.24 2.44 8.2 CBX25UHV-060 7785988 XP16-060-230 58000 15.5 12 56500 34400 3.62 2.52 8.5 CBX27UH-060 7785978 XP16-060-230 57000 XP16-060-230 57000 XP16-060-230 58000 XP16-060-230 57000 XP16-060-230 58500 14.5 11.5 56000 36200 3.32 2.46 8.5 15.7 12 55500 35800 3.34 2.48 8.5 15.7 12.2 55500 34000 3.38 2.42 8.2 15.5 11.5 56000 36000 3.36 2.46 8.5 15.5 11.5 61000 37400 3.48 2.44 8.5 CBX32M-060 CBX32MV-060 CBX32MV-068 CBX40UHV-060 CH23-68 EL180UH135E60D 7785980 7785979 7785982 7785981 7785983 XP16-060-230 58500 15.2 11.5 61500 37600 3.44 2.4 8.5 CH23-68 EL195UH135XE60D 7786017 XP16-060-230 58500 15.2 11.5 61500 37600 3.44 2.4 8.5 CH23-68 EL296UH135XE60D 7786015 XP16-060-230 59000 XP16-060-230 58500 XP16-060-230 59000 XP16-060-230 58500 XP16-060-230 54500 15.5 11.5 61500 37600 3.46 2.42 8.5 15.7 11.5 61000 37400 3.46 2.42 8.5 15.5 11.5 61500 37600 3.46 2.42 8.5 14.5 11.5 61500 37800 3.42 2.4 8.2 15.7 11.5 52500 34600 3.14 2.34 8.2 CH23-68 CH23-68 CH23-68 CH23-68 CH33-62D EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D EL180UH135E60D 7786013 7786012 7786014 7785974 7786008 XP16-060-230 54500 15.2 11 53000 35000 3.1 2.32 8.2 CH33-62D EL195UH135XE60D 7786007 XP16-060-230 54500 15.2 11 53000 35000 3.1 2.32 8.2 CH33-62D EL296UH135XE60D 7786016 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 19 AHRI SYSTEM MATCHES Model No. Cooling Capacity SEER EER XP16-060-230 54500 15.5 11 Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler 53000 34800 3.14 2.32 8.2 CH33-62D Furnace AHRI Reference EL296UH135XV60D 7786002 XP16-060-230 54500 15.7 11 53000 34800 3.14 2.32 8.2 CH33-62D SL280UH135V60D 7786010 XP16-060-230 54500 15.5 11 53000 34800 3.14 2.32 8.2 CH33-62D SLP98UH135XV60D 7786011 XP16-060-230 57500 XP16-060-230 57000 XP16-060-230 56500 XP16-060-230 57000 XP16-060-230 56500 15.2 12 57500 37200 3.28 2.46 8.5 15 12 57000 37200 3.18 2.44 8.2 15 11.5 57000 37400 3.14 2.42 8.2 15 12 57000 37200 3.18 2.44 8.2 15 11.5 57000 37400 3.14 2.42 8.2 CR33-50/60 CR33-50/60 CR33-50/60 CR33-50/60 CR33-50/60 EL180DF110E60C EL195DF110XE60C EL296DF090XV60C EL296DF110XE60C EL296DF110XV60C 7786006 7785997 7785998 7785995 7785996 XP16-060-230 57000 15.2 11.5 57500 37400 3.24 2.46 8.5 CR33-50/60 SL280DF090V60C 7786004 XP16-060-230 57000 15.2 12 57500 37200 3.24 2.46 8.5 CR33-50/60 SL280DF110V60C 7786018 XP16-060-230 56500 XP16-060-230 56500 XP16-060-230 56500 XP16-060-230 56500 XP16-060-230 57000 15 11.5 57000 37400 3.14 2.42 8.2 15 11.5 57000 37400 3.14 2.42 8.2 15 11.5 57000 37400 3.14 2.42 8.2 15 11.5 57000 37400 3.14 2.42 8.2 14.2 11.5 57500 37600 3.16 2.4 8.2 CR33-50/60 CR33-50/60 CR33-60 CR33-60 CR33-60 SLP98DF090XV60C SLP98DF110XV60C EL296DF110XV60C SLP98DF110XV60C 7786003 7786001 7786005 7786009 7785975 XP16-060-230 58500 15.7 12.2 53000 34800 3.22 2.38 8.5 CX34-62D EL180UH135E60D 7785991 XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 CX34-62D EL195UH135XE60D 7785986 XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 57000 15.2 11.5 53000 35200 3.18 2.36 8.2 15.7 12 53000 34800 3.22 2.38 8.5 15.7 12 53000 35000 3.2 2.38 8.5 15.7 12 53000 34800 3.22 2.38 8.5 14.5 11.5 53000 35000 3.16 2.36 8.2 CX34-62D CX34-62D CX34-62D CX34-62D CX34-62D EL296UH135XE60D EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D 7785984 7785989 7785993 7785999 7785976 XP16-060-230 58500 15.7 12.2 53000 34800 3.22 2.38 8.5 CX38-62D EL180UH135E60D 10085006 XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 CX38-62D EL195UH135XE60D 10085002 XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 CX38-62D EL296UH135XE60D 10085000 XP16-060-230 58500 15.7 12 53000 34800 3.22 2.38 8.5 CX38-62D EL296UH135XV60D 10085004 XP16-060-230 58000 15.7 12 53000 35000 3.2 2.38 8.5 CX38-62D SL280UH135V60D 10085008 XP16-060-230 58500 15.7 12 53000 34800 3.22 2.38 8.5 CX38-62D SLP98UH135XV60D 10085010 XP16-060-230 57000 14.5 11.5 53000 35000 3.16 2.36 8.2 CX38-62D 10084114 NOTES: All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section. When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra). To convert HSPF from Region IV to Region V - Divide by 1.15. XP16 - 2 to 5 Ton Heat Pump / Page 20 REVISIONS Sections AHRI System Matches Description of Change Updated Visit us at www.lennox.com For the latest technical information, www.LennoxPROs.com Contact us at 1-800-4-LENNOX NOTE - Due to Lennox' ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2017 Lennox Industries, Inc.Adobe PDF Library 10.0.1