PRODUCT SPECIFICATIONS

HEAT PUMP OUTDOOR UNITS
XP16
ELITE® Series R-410A - Two-Stage Compressor
Bulletin No. 210463 October 2017
Supersedes August 2017

SEER up to 17.00 2 to 5 Tons
Cooling Capacity - 23,600 to 59,000 Btuh Heating Capacity - 21,000 to 61,500 Btuh

MODEL NUMBER IDENTIFICATION

Refrigerant Type X = R-410A
Unit Type P = Heat Pump Outdoor Unit
Series

x p 16 - 036 - 230 - 6

Minor Revision Number

Voltage 230 = 208/230V-1phase-60hz
Nominal Cooling Capacity 024 = 2 tons 036 = 3 tons 048 = 4 tons 060 = 5 tons

FEATURES

CONTENTS AHRI System Matches............................................... 10 Dimensions................................................................... 7 Electrical Data.............................................................. 6 Features....................................................................... 2 Field Wiring................................................................... 8 Installation Clearances................................................. 8 Model Number Identification......................................... 1 Optional Accessories - Order Separately..................... 6 Sound Data................................................................... 8 Specifications............................................................... 6
WARRANTY
Compressor - Limited warranty for ten years in residential installations and five years in non-residential installations. All other covered components - Five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details.
APPROVALS AHRI Certified to AHRI Standard 210/240-2008. Sound rated in Lennox reverberant sound test room in accordance with test conditions included in AHRI Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated according to U.S. Department of Energy (DOE) test procedures. Air conditioners and components within bonded for grounding to meet safety standards for servicing required by UL and CEC. Units are ETL certified for the U.S. and Canada. ISO 9001 Registered Manufacturing Quality System. For expanded ratings, see www.LennoxPROs.com.

B

C

J

I D
H

K

E

G

F

APPLICATIONS
SEER up to 17.00.
HSPF (region IV) up to 9.50.
2 through 5 ton.
Single phase power supply.
Sound levels as low as 74 dB.
Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof.
Designed for applications with remotely located indoor air handler units or gas furnaces with indoor add-on coils.
When heat pumps are used with gas furnaces, a dual-fuel compatible thermostat or a zone control system with dual-fuel capabilities must be used (order separately).
Units shipped completely factory assembled, piped, and wired. Each unit is test operated at the factory insuring proper operation.
Installer must set heat pump, connect refrigerant lines, and make electrical connections to complete job.

XP16 - 2 to 5 Ton Heat Pump / Page 2

FEATURES
REFRIGERATION SYSTEM
R-410A Refrigerant Non-chlorine, ozone friendly, R-410A.
Unit is factory pre-charged. See Specification table.
Total system refrigerant charge is dependant on outdoor unit size, indoor unit size and refrigerant line length.
Refer to the unit-mounted charging sticker to determine correct amount of charge required.
AB Outdoor Coil Fan
Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. 060 models have a variable-speed outdoor fan motor for quiet operation.
Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs.
Fan motor has sleeve bearings and is inherently protected.
Motor totally enclosed for maximum protection from weather, dust and corrosion
Fan guard constructed of corrosion-resistant PVC (polyvinyl chloride) coated steel.
Fan service access accomplished by removal of fan guard.
C Copper Tube/Enhanced Fin Coil
Lennox designed and fabricated coil.
Ripple-edged aluminum fins.
Copper tube construction.
Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer.
Fin collars grip tubing for maximum contact area.
Inverted coil circuiting prevents ice buildup at coil base in low ambients. Discharge gas enters bottom of coil during defrost and heat of refrigerant flows counter to water drainage resulting in extremely clean and unobstructed fins and tubes.
Fin spacing allows rapid and complete water drainage.
Flared shoulder tubing connections/silver soldering construction.
Coil is factory tested under high pressure to insure leakproof construction.
Entire coil is accessible for cleaning.
D Expansion Valve - Outdoor Unit
Designed and sized specifically for use in heat pump system.
Sensing bulb is located on the line between reversing valve and the coil thus sensing suction temperature in the heat cycle.
Factory installed and piped.

Discharge Temperature Switch Shuts off unit if operating conditions cause the compressor discharge line temperature to rise above setpoint.
Protects compressor from excessive pressure / temperature.
Automatic reset when temperature drops below setpoint.
E High Pressure Switch
Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting.
Protects compressor from excessive condensing pressure.
Auto-reset.
F Low Pressure Switch
Shuts off unit if suction pressure falls below setting.
Provides loss of charge and freeze-up protection.
Auto-reset.
G Hi-Capacity Liquid Line Drier
Factory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system.
100% molecular-sieve bead type drier.
H Reversing Valve
4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa.
Valve operates on pressure differential between outdoor unit and indoor unit of the system. Factory installed.
Optional Accessories
Expansion Valve Kits Must be ordered separately and field installed on certain indoor units. See TXV Usage table.
Chatleff style fitting.
Freezestat Installs on or near the discharge line of the evaporator or on the suction line.
Senses suction line temperature and cycles the
compressor off when suction line temperature falls below its setpoint.
Opens at 29°F and closes at 58°F.
Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized, and sealed at factory.
Suction line fully insulated.
L15 lines are stubbed at both ends.
See Specifications table for selection.
Not available for -060 model and must be field fabricated.

XP16 - 2 to 5 Ton Heat Pump / Page 3

FEATURES

COMPRESSOR
I Copeland Scroll Ultra TechTM Two-Stage Compressor
Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced.
When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged.
During the compression process, there are several pockets in the scroll that are compressing gas. Modulation is achieved by venting a portion of the gas in the first suction pocket back to the low side of the compressor thereby reducing the effective displacement of the compressor.
A 24-volt DC solenoid valve inside the compressor controls staging. When the 3-way solenoid is energized it moves the lift ring assembly to block the ports and the compressor operates at full-load or 100% capacity. When the solenoid is de-energized the lift ring assembly moves to unblock the compressor ports and the compressor
operates at part-load or approximately 67% of its full-load capacity.
XP16 - 2 to 5 Ton Heat Pump / Page 4

The "loading" and "unloading" of the two stage scroll is done "on the fly" without shutting off the single-speed compressor motor between stages.
Low gas pulses during compression reduces operational sound levels.
Compressor motor is internally protected from excessive current and temperature.
Compressor is installed in the unit on specially formulated, resilient rubber mounts for better sound dampening and vibration free operation.
Crankcase Heater Crankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication.
CONTROLS
J Defrost Control
Control furnished as standard.
Gives a demand defrost cycle whenever system heating performance falls below optimum levels. The sensing element on coil determines when defrost cycle is required and when to terminate cycle.
Anti-short cycle (5 minutes) incorporated into the board.
Diagnostic LED's furnished as an aid in troubleshooting.
Conveniently located in control box.
Optional Accessories
Blower Relay Kit (For Use With EL195E and ML180E Gas Furnaces) Allows furnace blower speed changes when matched with two-stage heat pumps.
ComfortSense® 7500 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat.
4 Heat/2 Cool.
Auto-changeover.
Dual-fuel control with optional outdoor sensor.
Controls dehumidification during cooling mode and humidification during heating mode.
Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol® control, and equipment maintenance reminders.
Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen.
See the ComfortSense 7500 Product Specifications bulletin in the Controls section for more information.
Remote Outdoor Temperature Sensor for ComfortSense® 7500 Thermostat Allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol® applications.

FEATURES

CONTROLS (continued)
Optional Accessories
Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor.
This type of motor normally does not need a potential relay and start capacitor.
In conditions such as low voltage, kit may be required to increase the compressor starting torque.
Hard start kit is required in applications where the supply voltage is less than 230V.
Indoor Blower Off Delay Relay Delays the indoor blower-off time during the cooling cycle.
See AHRI Rating Tables for usage.
Indoor Blower Speed Relay Kit Relay kit provides the option of changing blower speeds on standard permanent split capacitor (PSC) multi-tap blower motors during cooling operation.
Provides optimum humidity control conditions by automatically reducing indoor blower speed during continuous fan operation or low stage compressor operation to reduce humidity levels.
Low Ambient Kit Heat pump will operate in the cooling mode satisfactorily down to 45°F outdoor air temperature without any additional controls.
Kit can be added in the field enabling unit to operate properly down to 30°F.
A Freezestat should be installed on compressors equipped with a low ambient kit.
A Compressor Low Ambient Cut-Off should be added to terminate compressor operation below recommended operation conditions (on/off operation, 30°F or modulating operation, 0°F.
Mild Weather Kit Heat pump units operate satisfactorily in the heating mode at outdoor air temperatures up to 75°F.
Mild Weather Kit can be field installed, allowing heating operation above 75°F.

CABINET
Heavy-gauge steel construction
Pre-painted cabinet finish.
Control box is conveniently located with all controls factory wired.
Large removable panel provides service access.
Drainage holes are provided in base section for moisture removal.
High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture.
PermaGuardTM Unit Base Durable zinc-coated base section resists rust and corrosion.
K SmartHingeTM Louvered Coil Protection
Steel louvered panels provides complete coil protection.
Panels are hinged to allow easy cleaning and servicing of coils.
Panels may be completely removed.
Interlocking tabs and slots assure tight fit on cabinet.
Refrigerant Line Connections, Electrical Inlets and Service Valves Vapor and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing.
Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Vapor valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system.
Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See dimension drawing.
Optional Accessories

Monitor Kit - Service Light Contains ambient compensating thermistor and service light thermostat.
For use with thermostats requiring input for indicator lights.
Outdoor Thermostat Kit An outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where twostage control is applicable.
Outdoor thermostat maintains the heating load on the low power input as long as possible before allowing the full power load to come on the line.
Thermostat kit and mounting box must be ordered extra.

Snow Guards For use in locations where the possibility of heavy snow or freezing rain accumulation may occur.
Heavy gauge powder coated steel guard deflects snow and ice away from the outdoor fan and prevents buildup on the fan guard.

XP16 - 2 to 5 Ton Heat Pump / Page 5

SPECIFICATIONS

General Data

Model No. Nominal Tonnage

Connections (sweat)

Liquid line (o.d.) - in. Vapor line (o.d.) - in.

Refrigerant

1 R-410A charge furnished

Outdoor Coil

Net face area - sq. ft. Outer coil Inner coil

Tube diameter - in.

No. of rows

Fins per inch

Outdoor Fan

Diameter - in. No. of blades

Motor hp

Cfm - 1st stage

2nd stage

Rpm - 1st stage

2nd stage

Watts - 1st stage

2nd stage

Shipping Data - lbs. 1 pkg.

XP16-024 2 3/8 3/4
8 lbs. 11 oz. 15.21 14.50 5/16 2 22 18 3 1/10 2232 - - 1035 - - 145
- - 222

XP16-036 3 3/8 7/8
10 lbs. 6 oz. 21.00 20.27 5/16 2 22 22 4 1/4 3900 - - 830 - - 295
- - 273

XP16-048 4 3/8 7/8
10 lbs. 9 oz. 22.17 21.51 5/16 2 2 26 3 1/3 4100 - - 855 - - 265
- - 294

XP16-060 5 3/8
1-1/8 11 lbs. 8 oz.
29.09 28.16 5/16
2 22 26 3 1/3 3690 4250 700 820 130
195 353

ELECTRICAL DATA

Line voltage data - 60hz

2 Maximum overcurrent protection (amps)

3 Minimum circuit ampacity

Compressor

Rated load amps

Locked rotor amps

Power factor

Outdoor Coil Fan Motor

Full load amps

4 208/230V-1ph 25 15.3
11.70 58.3 0.98 0.7

4 208/230V-1ph 35 20.8 15.3 83 0.99 1.7

4 208/230V-1ph 45 28.3
21.20 104 0.99 1.8

4 208/230V-1ph 60 36.8 27.1
152.9 0.99 2.8

OPTIONAL ACCESSORIES - ORDER SEPARATELY

Blower Relay Kit - for EL195E and

85W66

·

·

·

·

ML180E gas furnaces

ComfortSense® 7500 Thermostat

13H14

·

·

·

·

Outdoor Temperature Sensor - for

X2658

·

·

·

·

ComfortSense® 7500 Thermostat

Compressor Hard Start Kit - Required 63W22

·

in applications with less than 230V

10J42

·

·

63W24

·

Freezestat

3/8 in. tubing 93G35

·

·

·

·

5/8 in. tubing 50A93

·

·

·

·

Indoor Blower Speed Relay Kit

40K58

·

·

·

·

Indoor Blower Off Delay Relay

58M81

·

·

·

·

5 Low Ambient Kit

54M89

·

·

·

68M04

·

Mild Weather Kit

33M07

·

·

·

·

Monitor Kit - Service Light

76F53

·

·

·

·

Outdoor

Thermostat

56A87

·

·

·

·

Thermostat Kit

Mounting Box

31461

·

·

·

·

Refrigerant

L15-41-20 L15-41-40

·

Line Sets

L15-41-30 L15-41-50

L15-65-30 L15-65-40

·

·

L15-65-50

Field Fabricate

·

6 Snow Guards

28-1/2 x 27-1/2 in. X8781

·

39-1/2 x 35-5/8 in. Y1033

·

·

·

NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.

1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required.

2 HACR type breaker or fuse.

3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.

4 Hard start kit is required in applications where the supply voltage is less than 230V.

5 Compressor Low Ambient Cut-Off and Freezestat are recommended with Low Ambient Kit.

6 Adds 11-1/2 inches (292 mm) to unit height.

XP16 - 2 to 5 Ton Heat Pump / Page 6

DIMENSIONS - INCHES (MM)

TOP VIEW C
DISCHARGE AIR
SIDE VIEW UNIT SUPPORT FEET

SUCTION LINE CONNECTION
LIQUID LINE CONNECTION

B

LIQUID LINE CONNECTION
ELECTRICAL INLETS SUCTION LINE CONNECTION
4-3/4 4-1/4(108) (121)

A

2 (51)

1 (25)

END VIEW

UNIT SUPPORT FEET

8-1/2 (216)

9-1/2 (241)

16-7/8 (429)

26-7/8 (683)

8-3/4 (222)

8-1/4 (210)

5-1/2 (140)

13-1/2 (343)

XP16-024 BASE SECTION (Small Base)

8-3/4 (222)

3-3/4 (95)

3-1/8 (79)

30-3/4 (781)

4-5/8 (117)

XP16-036 TO -060 BASE SECTION (Large Base)

Model No.
XP16-024 XP16-036 XP16-048 XP16-060

A

B

C

in. mm in. mm in. mm

35 889 27 686 28 711

35 889 35-1/2 902 39-1/2 1003

35 889 35-1/2 902 39-1/2 1003

45 1143 35-1/2 902 39-1/2 1003

XP16 - 2 to 5 Ton Heat Pump / Page 7

FIELD WIRING

DISCONNECT SWITCH
(By Others)
A
OPTIONAL OUTDOOR THERMOSTAT
LENNOX OUTDOOR
UNIT

OPTIONAL ELECTRIC
HEAT LENNOX INDOOR UNIT
D

B
DISCONNECT SWITCH
(By Others) THERMOSTAT
(Optional)
C

A - Two Wire Power (see Electrical Data) B - Two or Three Wire Power (size to heater capacity) C - Twelve Wire Low Voltage 18 ga. minimum
Fourteen Wire Low Voltage with Optional Outdoor Thermostat D - Eight Wire Low Voltage 18 ga. minimum
Ten Wire Low Voltage with Optional Outdoor Thermostat NOTE - Field Wiring Not Furnished All wiring must conform to NEC or CEC and local electrical codes.

SOUND DATA

1 Unit Model No.

125

250

500

XP16-024

72.0

70.0

69.5

XP16-036

72.5

71.5

73.0

XP16-048

72.5

71.5

73.0

XP16-060

72.5

73.5

77.5

NOTE - the octave sound power data does not include tonal correction. 1 Tested according to AHRI Standard 270-2008 test conditions.

1000 68.5 70.5 70.5 72.5

2000 63.5 66.0 66.0 67.0

4000 58.0 60.5 60.5 62.5

8000 56.5 58.5 58.5 58.5

1 Sound Rating Number (dB)
74 76 76 78

INSTALLATION CLEARANCES
NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm). A clearance of 24 in. must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit.
XP16 - 2 to 5 Ton Heat Pump / Page 8

See NOTES

See NOTES

See NOTES

See NOTES

Control Box

TXV USAGE

Use this table for C33, CH23, CH33 and CR33 Field Installed TXV Match-Ups.

Model No.

Order No.

XP16-024

12J18

XP16-036

12J19

XP16-048

12J20

XP16-060

12J20

CX34 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed.
C33 and CH33 coils - Replace the factory installed orifice with the expansion valve listed.
CR33 and CH23 - Use the expansion valve listed.

MOST POPULAR MATCHES

Outdoor Unit Model No.

Indoor Unit Model No

XP16-024

CBX32MV-024/030

XP16-036

CBX32MV-036

XP16-048

CBX32MV-060

XP16-060

CBX32MV-060

AHRI STANDARD 210/240
Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation.

Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated.

XP16 - 2 to 5 Ton Heat Pump / Page 9

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-024-230 24200 16 12.5

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
21600 13300 3.64 2.48 8.5 C33-38A

Furnace SL280UH070V36A

AHRI Reference
7785776

XP16-024-230 24200 15.1 12.5 21600 13300 3.64 2.48 8.5 C33-38A

SL280UH070XV36A 7785773

XP16-024-230 24000 16 12.5 21600 13300 3.6 2.46 8.5 C33-38B

EL296UH070XV36B 7785768

XP16-024-230 24200 XP16-024-230 24000 XP16-024-230 23800 XP16-024-230 23800 XP16-024-230 23800

16 12.5 21600 13300 3.66 2.5 8.5 16 12.5 21600 13300 3.6 2.46 8.5 16 12.2 22400 13900 3.34 2.44 8.5 16 12.2 22400 13900 3.34 2.44 8.5 15.5 12.2 22400 13900 3.34 2.42 8.5

C33-38B C33-38B C35-30A C35-30A C35-30B

SL280UH090V36B SLP98UH070XV36B SL280UH070V36A SL280UH070XV36A EL296UH070XV36B

7785762 7785767 9910944 9910945 9910946

XP16-024-230 23600 15 12.2 22400 13800 3.36 2.44 8.5 C35-30B

SL280UH090V36B 9910947

XP16-024-230 23800 15.5 12.2 22400 13900 3.34 2.42 8.5 C35-30B

SLP98UH070XV36B 9910948

XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200

16 12.2 22200 13700 3.52 2.42 8.5 16 12.2 22200 13700 3.52 2.42 8.5 15.5 12.2 22200 13700 3.52 2.42 8.5 15 12.5 22000 13600 3.5 2.42 8.2 15.5 12.2 22200 13700 3.52 2.42 8.5

C35-36A C35-36A C35-36B C35-36B C35-36B

SL280UH070V36A SL280UH070XV36A EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B

9910949 9910950 9910951 9910952 9910953

XP16-024-230 24200 16 12.5 21600 13300 3.64 2.48 8.5 C37-38A

SL280UH070V36A 10084930

XP16-024-230 24200 15.1 12.5 21600 13300 3.64 2.48 8.5 C37-38A

SL280UH070XV36A 10084929

XP16-024-230 24000 XP16-024-230 24200 XP16-024-230 24000 XP16-024-230 24000 XP16-024-230 24000

16 12.5 21600 13300 3.6 2.46 8.5 16 12.5 21600 13300 3.66 2.5 8.5 16 12.5 21600 13300 3.6 2.46 8.5 15.5 12 22600 13600 3.6 2.54 8.5 14.5 12 23400 14400 3.4 2.42 8.2

C37-38B C37-38B C37-38B CBA27UHE-024 CBX25UHV-030

EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B

10084926 10084923 10084925 10258586 7785764

XP16-024-230 24200 15.5 11.2 22400 13700 3.7 2.54 8.5 CBX27UH-024

7785754

XP16-024-230 24000 16 12.5 22200 12900 3.62 2.38 8.5 CBX27UH-030

7785755

XP16-024-230 24400 16.5 12.5 22400 14000 3.72 2.6 8.5 CBX32MV-024/030

7785758

XP16-024-230 24400 17 XP16-024-230 24200 16 XP16-024-230 24000 16 XP16-024-230 24400 16 XP16-024-230 24800 16

12.5 22400 13100 3.66 2.38 8.5 12 22200 13000 3.6 2.38 8.5 12 22200 12900 3.6 2.36 8.5 12.5 22400 13100 3.68 2.4 8.5 12 21000 13900 3.3 2.5 8.5

CBX32MV-036 CBX40UHV-024 CBX40UHV-030 CBX40UHV-036 CH33-31B

EL296UH070XV36B

7785757 7785759 7785756 7785765 7785771

XP16-024-230 24800 15.1 12.2 21000 13900 3.34 2.52 8.2 CH33-31B

SL280UH090V36B 7785775

XP16-024-230 24800 16 12 21000 13900 3.3 2.5 8.5 CH33-31B

SLP98UH070XV36B 7785774

XP16-024-230 23800 XP16-024-230 23800 XP16-024-230 23800 XP16-024-230 23600 XP16-024-230 23600

15.5 12.2 21800 13600 3.24 2.3 8.2 15 12.2 21600 13500 3.24 2.3 8.2 15.5 12.2 21800 13600 3.24 2.3 8.2 16 12.5 23200 13900 3.36 2.34 8.2 16 12.5 23200 13900 3.36 2.36 8.2

CH35-30B CH35-30B CH35-30B CR33-30/36 CR33-30/36

EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B SLP98DF070XV36B SLP98DF090XV36C

9910941 9910942 9910943 7785772 7785766

XP16-024-230 24200 16 12.5 21600 13300 3.64 2.48 8.5 CX34-38A

SL280UH070V36A 7785760

XP16-024-230 24200 16 12.5 21600 13300 3.64 2.48 8.5 CX34-38A

SL280UH070XV36A 7785770

XP16-024-230 24200 16 XP16-024-230 24400 16 XP16-024-230 24000 16 XP16-024-230 23800 16 XP16-024-230 23800 16

12.5 21600 13400 3.62 2.48 8.5 12.5 21800 13400 3.68 2.48 8.5 12.5 21600 13300 3.6 2.46 8.5 12.2 22400 13900 3.34 2.44 8.5 12.2 22400 13900 3.34 2.44 8.5

CX34-38B CX34-38B CX34-38B CX35-30A CX35-30A

EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B SL280UH070V36A SL280UH070XV36A

7785769 7785761 7785763 9910931 9910932

XP16-024-230 23800 15.5 12.2 22400 13900 3.34 2.42 8.5 CX35-30B

EL296UH070XV36B 9910933

XP16-024-230 23600 15 12.2 22400 13800 3.36 2.44 8.5 CX35-30B

SL280UH090V36B 9910934

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 10

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-024-230 23800 15.5 12.2

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
22400 13900 3.34 2.42 8.5 CX35-30B

Furnace

AHRI Reference

SLP98UH070XV36B 9910935

XP16-024-230 24200 16 12.2 22200 13700 3.52 2.42 8.5 CX35-36A

SL280UH070V36A 9910936

XP16-024-230 24200 16 12.2 22200 13700 3.52 2.42 8.5 CX35-36A

SL280UH070XV36A 9910937

XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200 XP16-024-230 24200

15.5 12.2 22200 13700 3.52 2.42 8.5 15 12.5 22000 13600 3.5 2.42 8.2 15.5 12.2 22200 13700 3.52 2.42 8.5 16 12.5 21600 13300 3.64 2.48 8.5 16 12.5 21600 13300 3.64 2.48 8.5

CX35-36B CX35-36B CX35-36B CX38-38A CX38-38A

EL296UH070XV36B SL280UH090V36B SLP98UH070XV36B SL280UH070V36A SL280UH070XV36A

9910938 9910939 9910940 10084921 10084928

XP16-024-230 24200 16 12.5 21600 13400 3.62 2.48 8.5 CX38-38B

EL296UH070XV36B 10084927

XP16-024-230 24400 16 12.5 21800 13400 3.68 2.48 8.5 CX38-38B

SL280UH090V36B 10084922

XP16-024-230 24000 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37200

16 12.5 21600 13300 3.6 2.46 8.5 16 13 32800 21600 3.1 2.56 8.5 15.5 12.5 33600 22200 3.02 2.46 8.5 16 12.5 33200 21800 3.08 2.52 8.5 16 13 33000 21800 3.1 2.56 8.5

CX38-38B C33-43 C33-43 C33-43 C33-43

SLP98UH070XV36B EL180UH070E36B EL195UH045XE36B EL195UH070XE36B EL195UH090XE48C

10084924 7785832 7785808 7785837 7785849

XP16-036-230 37000 15.5 12.5 33600 22200 3.02 2.46 8.5 C33-43

EL296UH045XE36B 7785848

XP16-036-230 37000 16 12.5 33200 21800 3.08 2.52 8.5 C33-43

EL296UH070XE36B 7785822

XP16-036-230 37200 16 XP16-036-230 37200 16 XP16-036-230 37200 16 XP16-036-230 37000 16 XP16-036-230 37800 16

12.5 33200 22000 3.06 2.52 8.5 13 33000 21800 3.1 2.56 8.5 13 33000 21800 3.12 2.56 8.5 13 33000 21600 3.1 2.54 8.5 13 33400 22000 3.18 2.58 8.5

C33-43 C33-43 C33-43 C33-43 C33-43

EL296UH070XV36B EL296UH090XE48C EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C

7785843 7785811 7785844 7785833 7785828

XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 C33-43

EL296UH110XV60C 7785803

XP16-036-230 37200 16 13 32800 21600 3.12 2.56 8.5 C33-43

SL280UH090V36B 7785827

XP16-036-230 37200 16 13 33000 21800 3.14 2.58 8.5 C33-43

SL280UH090V48B 7785802

XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 C33-43 XP16-036-230 37200 16 13 33000 21800 3.14 2.58 8.5 C33-43 XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 C33-43 XP16-036-230 37600 16 13 33200 21800 3.16 2.56 8.5 C33-43 XP16-036-230 37600 16 13 33200 21800 3.16 2.56 8.5 C33-43

SL280UH090V60C SL280UH090XV48B SL280UH090XV60C SL280UH110V60C SL280UH110XV60C

7785810 7785809 7785839 7785850 7785812

XP16-036-230 37200 16 12.5 33200 22000 3.06 2.52 8.5 C33-43

SLP98UH070XV36B 7785838

XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 C33-43

SLP98UH090XV36C 7785845

XP16-036-230 37000 XP16-036-230 37800 XP16-036-230 37600 XP16-036-230 36800 XP16-036-230 36800

16 13 16 13 16 13 14.5 12 14.5 12

33000 33400 33200 33600 33600

21600 22000 21800 22400 22400

3.1 2.54 8.5 3.18 2.58 8.5 3.18 2.58 8.5 2.96 2.42 8.2 2.96 2.42 8.2

C33-43 C33-43 C33-43 C33-43B C33-43C

SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C

7785834 7785817 7785804 7785782 8444069

XP16-036-230 37400 16 13 34000 23000 2.88 2.4 8.2 C33-50/60C

EL296UH090XV60C 7785794

XP16-036-230 37200 16 13 33600 22800 2.86 2.4 8.2 C33-50/60C

EL296UH110XV60C 7785796

XP16-036-230 37400 16 13 33800 22800 2.88 2.4 8.2 C33-50/60C XP16-036-230 37400 16 13 33800 22800 2.88 2.4 8.2 C33-50/60C XP16-036-230 37400 16 13 34000 23000 2.88 2.4 8.2 C33-50/60C XP16-036-230 37200 16 13 33600 22800 2.86 2.4 8.2 C33-50/60C XP16-036-230 37000 16 13 32800 21600 3.1 2.56 8.5 C37-43B

SL280UH090V60C SL280UH090XV60C SLP98UH090XV60C SLP98UH110XV60C EL180UH070E36B

7785797 7785798 7785795 7785789 10084970

XP16-036-230 37000 15.5 12.5 33600 22200 3.02 2.46 8.5 C37-43B

EL195UH045XE36B 10084947

XP16-036-230 37000 16 12.5 33200 21800 3.08 2.52 8.5 C37-43B

EL195UH070XE36B 10084975

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 11

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-036-230 37000 15.5 12.5

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
33600 22200 3.02 2.46 8.5 C37-43B

Furnace

AHRI Reference

EL296UH045XE36B 10084985

XP16-036-230 37000 16 12.5 33200 21800 3.08 2.52 8.5 C37-43B

EL296UH070XE36B 10084960

XP16-036-230 37200 16 12.5 33200 22000 3.06 2.52 8.5 C37-43B

EL296UH070XV36B 10084980

XP16-036-230 37200 XP16-036-230 37200 XP16-036-230 37200 XP16-036-230 37200 XP16-036-230 36800

16 13 32800 21600 3.12 2.56 8.5 16 13 33000 21800 3.14 2.58 8.5 16 13 33000 21800 3.14 2.58 8.5 16 12.5 33200 22000 3.06 2.52 8.5 14.5 12 33600 22400 2.96 2.42 8.2

C37-43B C37-43B C37-43B C37-43B C37-43B

SL280UH090V36B SL280UH090V48B SL280UH090XV48B SLP98UH070XV36B

10084965 10084941 10084948 10084976 10084111

XP16-036-230 37200 16 13 33000 21800 3.1 2.56 8.5 C37-43C

EL195UH090XE48C 10084986

XP16-036-230 37200 16 13 33000 21800 3.1 2.56 8.5 C37-43C

EL296UH090XE48C 10084950

XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 C37-43C XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 C37-43C XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 C37-43C XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 C37-43C XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 C37-43C

EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C EL296UH110XV60C SL280UH090V60C

10084981 10084971 10084966 10084942 10084949

XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 C37-43C

SL280UH090XV60C 10084977

XP16-036-230 37600 16 13 33200 21800 3.16 2.56 8.5 C37-43C

SL280UH110V60C 10084987

XP16-036-230 37600 16 13 33200 21800 3.16 2.56 8.5 C37-43C XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 C37-43C XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 C37-43C XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 C37-43C XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 C37-43C

SL280UH110XV60C SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C

10084951 10084982 10084972 10084956 10084943

XP16-036-230 36800 14.5 12 33600 22400 2.96 2.42 8.2 C37-43C

10084112

XP16-036-230 37400 16 13 34000 23000 2.88 2.4 8.2 C37-50/60C

EL296UH090XV60C 10084933

XP16-036-230 37200 16 13 33600 22800 2.86 2.4 8.2 C37-50/60C

EL296UH110XV60C 10084935

XP16-036-230 37400 16 XP16-036-230 37400 16 XP16-036-230 37400 16 XP16-036-230 37200 16 XP16-036-230 36000 16

13 33800 22800 2.88 2.4 8.2 13 33800 22800 2.88 2.4 8.2 13 34000 23000 2.88 2.4 8.2 13 33600 22800 2.86 2.4 8.2 12.5 35400 23000 3.46 2.66 9

C37-50/60C C37-50/60C C37-50/60C C37-50/60C CBA27UHE-042

SL280UH090V60C SL280UH090XV60C SLP98UH090XV60C SLP98UH110XV60C

10084936 10084937 10084934 10084931 10258587

XP16-036-230 36200 14.5 12 36800 24400 2.8 2.68 8.2 CBX25UH-036

7785904

XP16-036-230 36200 16 12.5 34600 23200 3.18 2.58 8.5 CBX25UHV-036

7785792

XP16-036-230 36200 XP16-036-230 37600 XP16-036-230 35600 XP16-036-230 36400 XP16-036-230 37600

15.5 12.5 34400 23000 3.2 2.6 9 16 13 34200 23400 3.36 2.84 9.5 14.5 12 34800 23400 3.12 2.52 8.7 16.5 12.5 34600 23200 3.2 2.6 9 16 13 34200 23400 3.36 2.84 9.5

CBX27UH-036 CBX27UH-042 CBX32M-036 CBX32MV-036 CBX32MV-048

7785786 7785903 7785785 7785784 7785901

XP16-036-230 36200 16 13 34400 23000 3.22 2.62 9

CBX40UHV-030

7785788

XP16-036-230 36200 16 12.5 34600 23200 3.22 2.6 9

CBX40UHV-036

7785787

XP16-036-230 37400 XP16-036-230 37400 XP16-036-230 38000 XP16-036-230 38000 XP16-036-230 37600

16 13.5 34400 23000 3.24 2.62 9 16 13.5 34400 22800 3.26 2.64 8.5 16 13 33000 22200 3.38 2.6 8.5 16 13 33000 22200 3.44 2.64 9 15.5 12.5 33200 22400 3.3 2.54 8.5

CBX40UHV-042 CBX40UHV-048 CH33-43B CH33-43B CH33-43B

EL180UH070E36B EL180UH090E48B EL195UH045XE36B

7785902 7785783 7785898 7785896 7785884

XP16-036-230 37800 15.5 12.5 33000 22400 3.3 2.56 8.5 CH33-43B

EL195UH070XE36B 7785889

XP16-036-230 37600 15.5 12.5 33200 22400 3.3 2.54 8.5 CH33-43B

EL296UH045XE36B 7785892

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 12

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-036-230 37800 16 12.5

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
33000 22400 3.34 2.58 8.5 CH33-43B

Furnace

AHRI Reference

EL296UH045XV36B 7785905

XP16-036-230 37800 15.5 12.5 33000 22400 3.3 2.56 8.5 CH33-43B

EL296UH070XE36B 7785894

XP16-036-230 37800 16 12.5 33000 22200 3.36 2.58 8.5 CH33-43B

EL296UH070XV36B 7785906

XP16-036-230 37800 XP16-036-230 38000 XP16-036-230 38000 XP16-036-230 37800 XP16-036-230 37400

16 13 32600 22000 3.4 2.64 8.5 16 13 32800 22000 3.4 2.62 8.5 16 13 32800 22000 3.4 2.62 8.5 16 12.5 33000 22200 3.36 2.58 8.5 14.5 12 33200 22600 3.22 2.5 8.5

CH33-43B CH33-43B CH33-43B CH33-43B CH33-43B

SL280UH090V36B SL280UH090V48B SL280UH090XV48B SLP98UH070XV36B

7785897 7785895 7785891 7785899 7785777

XP16-036-230 37400 16 13 33000 21800 3.16 2.58 8.5 CH33-43C

EL195UH090XE48C 7785900

XP16-036-230 37400 16 13 33000 21800 3.16 2.58 8.5 CH33-43C

EL296UH090XE48C 7785885

XP16-036-230 37400 16 13 32400 21800 3.32 2.56 8.5 CH33-43C XP16-036-230 37200 16 13 32400 21800 3.32 2.58 8.5 CH33-43C XP16-036-230 38000 16 13 32800 22000 3.36 2.58 8.5 CH33-43C XP16-036-230 37800 16 13 32600 22000 3.36 2.6 8.5 CH33-43C XP16-036-230 38000 16 13 32800 22000 3.36 2.58 8.5 CH33-43C

EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C EL296UH110XV60C SL280UH090V60C

7785890 7785893 7785790 7785791 7785883

XP16-036-230 38000 16 13 32600 22000 3.38 2.62 8.5 CH33-43C

SL280UH090XV60C 7785888

XP16-036-230 37800 16 13 32600 22000 3.36 2.6 8.5 CH33-43C

SL280UH110V60C 7785880

XP16-036-230 37800 16 13 32600 22000 3.34 2.58 8.5 CH33-43C XP16-036-230 37400 16 13 32400 21800 3.32 2.56 8.5 CH33-43C XP16-036-230 37200 16 13 32400 21800 3.32 2.58 8.5 CH33-43C XP16-036-230 38000 16 13 32800 22000 3.36 2.58 8.5 CH33-43C XP16-036-230 37800 16 13 32600 22000 3.36 2.6 8.5 CH33-43C

SL280UH110XV60C SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C

7785868 7785872 7785853 7785876 7785860

XP16-036-230 36800 14.5 12 33600 22400 3.02 2.44 8.2 CH33-43C

7785779

XP16-036-230 37000 16 13 33000 21800 3.16 2.54 8.5 CH33-48C

EL195UH090XE48C 7785855

XP16-036-230 37000 16 13 33000 21800 3.16 2.54 8.5 CH33-48C

EL296UH090XE48C 7785866

XP16-036-230 37000 16 13 33000 21800 3.16 2.54 8.5 CH33-48C XP16-036-230 36800 16 13 32800 21800 3.14 2.56 8.5 CH33-48C XP16-036-230 37600 16 13 33200 22000 3.2 2.56 8.5 CH33-48C XP16-036-230 37400 16 13 33000 21800 3.2 2.56 8.5 CH33-48C XP16-036-230 37600 16 13 33200 22000 3.24 2.6 8.5 CH33-48C

EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C EL296UH110XV60C SL280UH090V60C

7785881 7785877 7785869 7785873 7785854

XP16-036-230 37600 16 13 33200 22000 3.24 2.6 8.5 CH33-48C

SL280UH090XV60C 7785865

XP16-036-230 37200 16 13 33200 22000 3.2 2.56 8.5 CH33-48C

SL280UH110V60C 7785861

XP16-036-230 37200 16 13 33200 22000 3.2 2.56 8.5 CH33-48C XP16-036-230 37000 16 13 33000 21800 3.16 2.54 8.5 CH33-48C XP16-036-230 36800 16 13 32800 21800 3.14 2.56 8.5 CH33-48C XP16-036-230 37600 16 13 33200 22000 3.2 2.56 8.5 CH33-48C XP16-036-230 37400 16 13 33000 21800 3.2 2.56 8.5 CH33-48C

SL280UH110XV60C SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C

7785863 7785882 7785878 7785870 7785874

XP16-036-230 36400 14.5 12 33600 22400 3 2.42 8.2 CH33-48C

7785780

XP16-036-230 36400 16 13 35800 22400 3 2.68 8.5 CR33-48B

EL180DF070E36B 7785859

XP16-036-230 36600 XP16-036-230 36400 XP16-036-230 36600 XP16-036-230 36400 XP16-036-230 36000

15.5 12 36400 23000 2.96 2.6 8.5 15.5 12.5 36000 22600 3 2.64 8.7 15.5 12 36400 23000 2.96 2.6 8.5 15.5 12.5 36000 22600 3 2.64 8.7 15 12.5 36000 22800 2.96 2.62 8.5

CR33-48B CR33-48B CR33-48B CR33-48B CR33-48B

EL195DF045XE36B EL195DF070XE48B EL296DF045XE36B EL296DF070XE48B EL296DF070XV48B

7785862 7785864 7785871 7785879 8203819

XP16-036-230 36600 16 12.5 36000 22600 3.02 2.66 8.5 CR33-48B

SL280DF090V48B 7785875

XP16-036-230 36200 16 12.5 36000 22600 2.98 2.64 8.5 CR33-48B

SLP98DF070XV36B 7785887

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 13

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-036-230 36000 14 11.5

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
36600 23200 2.88 2.54 8.2 CR33-48B

Furnace

AHRI Reference
7785778

XP16-036-230 37200 16 13 36000 22600 3.08 2.72 8.5 CR33-48C

SL280DF090V60C 7785856

XP16-036-230 36800 16 13 36000 22600 3.06 2.72 8.5 CR33-48C

SL280DF110V60C 7785867

XP16-036-230 36600 16 XP16-036-230 36600 16 XP16-036-230 36800 16 XP16-036-230 36800 16 XP16-036-230 37000 16

12.5 36000 22600 3 2.66 8.5 12.5 36000 22600 3.02 2.68 8.5 12.5 36200 22600 3.06 2.68 8.5 12.5 36200 22800 3.06 2.7 8.5 13 32800 21600 3.1 2.56 8.5

CR33-48C CR33-48C CR33-48C CR33-48C CX34-43

SLP98DF090XV36C SLP98DF090XV48C SLP98DF090XV60C SLP98DF110XV60C EL180UH070E36B

7785886 7785818 7785851 7785840 7785852

XP16-036-230 37000 15.5 12.5 33600 22200 3.02 2.46 8.5 CX34-43

EL195UH045XE36B 7785813

XP16-036-230 37000 16 12.5 33200 21800 3.08 2.52 8.5 CX34-43

EL195UH070XE36B 7785823

XP16-036-230 37200 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37200 XP16-036-230 37200

16 13 33000 21800 3.1 2.56 8.5 15.5 12.5 33600 22200 3.02 2.46 8.5 16 12.5 33200 21800 3.08 2.52 8.5 16 12.5 33200 22000 3.06 2.52 8.5 16 13 33000 21800 3.1 2.56 8.5

CX34-43 CX34-43 CX34-43 CX34-43 CX34-43

EL195UH090XE48C EL296UH045XE36B EL296UH070XE36B EL296UH070XV36B EL296UH090XE48C

7785835 7785846 7785857 7785819 7785858

XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 CX34-43

EL296UH090XV36C 7785820

XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 CX34-43

EL296UH090XV48C 7785841

XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 CX34-43 XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 CX34-43 XP16-036-230 37200 16 13 32800 21600 3.12 2.56 8.5 CX34-43 XP16-036-230 37200 16 13 33000 21800 3.12 2.58 8.5 CX34-43 XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 CX34-43

EL296UH090XV60C EL296UH110XV60C SL280UH090V36B SL280UH090V48B SL280UH090V60C

7785830 7785825 7785829 7785824 7785801

XP16-036-230 37200 16 13 33000 21800 3.12 2.58 8.5 CX34-43

SL280UH090XV48B 7785800

XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 CX34-43

SL280UH090XV60C 7785807

XP16-036-230 37400 16 13 33200 21800 3.14 2.56 8.5 CX34-43

SL280UH110V60C 7785836

XP16-036-230 37400 16 XP16-036-230 37200 16 XP16-036-230 37200 16 XP16-036-230 37000 16 XP16-036-230 37800 16

13 33200 21800 3.14 2.56 8.5 12.5 33200 22000 3.06 2.52 8.5 13 33000 21800 3.12 2.56 8.5 13 33000 21600 3.1 2.54 8.5 13 33400 22000 3.18 2.58 8.5

CX34-43 CX34-43 CX34-43 CX34-43 CX34-43

SL280UH110XV60C SLP98UH070XV36B SLP98UH090XV36C SLP98UH090XV48C SLP98UH090XV60C

7785847 7785806 7785821 7785842 7785831

XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 CX34-43

SLP98UH110XV60C 7785826

XP16-036-230 36800 14.5 12 33600 22400 2.96 2.42 8.2 CX34-43

7785781

XP16-036-230 37400 XP16-036-230 37200 XP16-036-230 37400 XP16-036-230 37400 XP16-036-230 37400

16 13 16 13 16 13 16.5 13 16 13

34000 23000 2.88 2.4 8.2 33600 22800 2.86 2.4 8.2 33800 22800 2.88 2.4 8.2 33800 22800 2.88 2.4 8.2 34000 23000 2.88 2.4 8.2

CX34-50/60C CX34-50/60C CX34-50/60C CX34-50/60C CX34-50/60C

EL296UH090XV60C EL296UH110XV60C SL280UH090V60C SL280UH090XV60C SLP98UH090XV60C

7785814 7785816 7785793 7785799 7785815

XP16-036-230 37400 16 13 33600 22800 2.86 2.4 8.2 CX34-50/60C

SLP98UH110XV60C 7785805

XP16-036-230 37000 16 13 32800 21600 3.1 2.56 8.5 CX38-43B

EL180UH070E36B 10084988

XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37000 XP16-036-230 37200

15.5 12.5 33600 22200 3.02 2.46 8.5 16 12.5 33200 21800 3.08 2.52 8.5 15.5 12.5 33600 22200 3.02 2.46 8.5 16 12.5 33200 21800 3.08 2.52 8.5 16 12.5 33200 22000 3.06 2.52 8.5

CX38-43B CX38-43B CX38-43B CX38-43B CX38-43B

EL195UH045XE36B EL195UH070XE36B EL296UH045XE36B EL296UH070XE36B EL296UH070XV36B

10084952 10084961 10084983 10084989 10084957

XP16-036-230 37200 16 13 32800 21600 3.12 2.56 8.5 CX38-43B

SL280UH090V36B 10084967

XP16-036-230 37200 16 13 33000 21800 3.12 2.58 8.5 CX38-43B

SL280UH090V48B 10084962

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 14

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-036-230 37200 16 13

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
33000 21800 3.12 2.58 8.5 CX38-43B

Furnace

AHRI Reference

SL280UH090XV48B 10084939

XP16-036-230 37200 16 12.5 33200 22000 3.06 2.52 8.5 CX38-43B

SLP98UH070XV36B 10084945

XP16-036-230 36800 14.5 12 33600 22400 2.96 2.42 8.2 CX38-43B

10086664

XP16-036-230 37200 16 13 33000 21800 3.1 2.56 8.5 CX38-43C XP16-036-230 37200 16 13 33000 21800 3.1 2.56 8.5 CX38-43C XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 CX38-43C XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 CX38-43C XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 CX38-43C

EL195UH090XE48C EL296UH090XE48C EL296UH090XV36C EL296UH090XV48C EL296UH090XV60C

10084973 10084990 10084958 10084978 10084968

XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 CX38-43C

EL296UH110XV60C 10084963

XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 CX38-43C

SL280UH090V60C 10084940

XP16-036-230 37800 16 13 33200 21800 3.18 2.58 8.5 CX38-43C XP16-036-230 37400 16 13 33200 21800 3.14 2.56 8.5 CX38-43C XP16-036-230 37400 16 13 33200 21800 3.14 2.56 8.5 CX38-43C XP16-036-230 37200 16 13 33000 21800 3.12 2.56 8.5 CX38-43C XP16-036-230 37000 16 13 33000 21600 3.1 2.54 8.5 CX38-43C

SL280UH090XV60C SL280UH110V60C SL280UH110XV60C SLP98UH090XV36C SLP98UH090XV48C

10084946 10084974 10084984 10084959 10084979

XP16-036-230 37800 16 13 33400 22000 3.18 2.58 8.5 CX38-43C

SLP98UH090XV60C 10084969

XP16-036-230 37600 16 13 33200 21800 3.18 2.58 8.5 CX38-43C

SLP98UH110XV60C 10084964

XP16-036-230 36800 XP16-036-230 37400 XP16-036-230 37200 XP16-036-230 37400 XP16-036-230 37400

14.5 12 16 13 16 13 16 13 16.5 13

33600 34000 33600 33800 33800

22400 23000 22800 22800 22800

2.96 2.42 8.2 2.88 2.4 8.2 2.86 2.4 8.2 2.88 2.4 8.2 2.88 2.4 8.2

CX38-43C CX38-50/60C CX38-50/60C CX38-50/60C CX38-50/60C

EL296UH090XV60C EL296UH110XV60C SL280UH090V60C SL280UH090XV60C

10086665 10084953 10084955 10084932 10084938

XP16-036-230 37400 16 13 34000 23000 2.88 2.4 8.2 CX38-50/60C

SLP98UH090XV60C 10084954

XP16-036-230 37400 16 13 33600 22800 2.86 2.4 8.2 CX38-50/60C

SLP98UH110XV60C 10084944

XP16-048-230 47000 15.5 12 41500 28000 3.46 2.58 9

C33-62C

EL180UH090E60C 7785931

XP16-048-230 47500 15 XP16-048-230 47000 15 XP16-048-230 47000 15 XP16-048-230 47000 15 XP16-048-230 47000 15

11.5 42000 28600 3.44 2.56 9 12 41500 28200 3.4 2.54 8.7 12 41500 28200 3.44 2.56 9 12 41500 28200 3.4 2.54 8.7 12 41500 28200 3.44 2.56 9

C33-62C C33-62C C33-62C C33-62C C33-62C

EL180UH110E60C EL195UH090XE48C EL195UH110XE60C EL296UH090XE48C EL296UH110XE60C

7785924 7785914 7785917 7785915 7785918

XP16-048-230 46500 15 11.5 42000 28000 3.22 2.36 8.2 C35-49C

EL180UH090E60C 9910856

XP16-048-230 47000 15 11.5 42500 28600 3.22 2.36 8.2 C35-49C

EL180UH110E60C 9910857

XP16-048-230 46500 15 XP16-048-230 46500 15 XP16-048-230 46500 15 XP16-048-230 46500 15 XP16-048-230 46500 15

11.5 42000 28000 3.2 2.34 8.2 11.5 42500 28400 3.2 2.34 8.2 11.5 42500 28400 3.2 2.34 8.2 11.5 42000 28000 3.2 2.34 8.2 11.5 42000 28200 3.18 2.36 8.2

C35-49C C35-49C C35-49C C35-49C C35-49C

EL195UH110XE60C EL296UH090XV48C EL296UH090XV60C EL296UH110XE60C EL296UH110XV48C

9910858 9910859 9910860 9910862 9910861

XP16-048-230 46500 15 11.5 42500 28200 3.22 2.34 8.2 C35-49C

EL296UH110XV60C 9910863

XP16-048-230 46500 15.5 11.5 42000 28000 3.22 2.36 8.2 C35-49C

SL280UH090V60C 9910864

XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 47000

15.5 11.5 42000 28000 3.22 2.36 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2 15 11.5 42000 28200 3.18 2.34 8.2 15.5 12 43000 26000 3.52 2.32 8.2

C35-49C C35-49C C35-49C C35-49C C35-60C

SL280UH090XV60C SL280UH110V60C SL280UH110XV60C SLP98UH090XV48C EL180UH090E60C

9910865 9910866 9910867 9910868 9910869

XP16-048-230 47500 15.5 11.5 44000 26600 3.54 2.32 8.2 C35-60C

EL180UH110E60C 9910870

XP16-048-230 46500 15 11.5 43500 26200 3.5 2.3 8.2 C35-60C

EL195UH090XE48C 9910871

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 15

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-048-230 47000 15.5 11.5

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
43500 26000 3.52 2.3 8.2 C35-60C

Furnace

AHRI Reference

EL195UH110XE60C 9910872

XP16-048-230 46500 15 11.5 43500 26200 3.5 2.3 8.2 C35-60C

EL296UH090XE48C 9910873

XP16-048-230 47000 15.5 11.5 44000 26400 3.52 2.28 8.2 C35-60C

EL296UH090XV48C 9910874

XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000

15.5 11.5 44000 26400 3.52 2.28 8.2 15.5 11.5 43500 26000 3.52 2.3 8.2 15.5 11.5 43500 26200 3.52 2.3 8.2 15.5 11.5 43500 26200 3.5 2.28 8.2 15.5 11.5 43500 26000 3.54 2.32 8.2

C35-60C C35-60C C35-60C C35-60C C35-60C

EL296UH090XV60C EL296UH110XE60C EL296UH110XV48C EL296UH110XV60C SL280UH090V60C

9910875 9910877 9910876 9910878 9910879

XP16-048-230 47000 15.5 11.5 43500 26000 3.54 2.32 8.2 C35-60C

SL280UH090XV60C 9910880

XP16-048-230 47000 15.5 11.5 43500 26000 3.54 2.32 8.2 C35-60C

SL280UH110V60C 9910881

XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47500

15.5 11.5 43500 26000 3.54 2.32 8.2 15.5 11.5 43500 26200 3.5 2.3 8.2 15.5 11.5 43500 26200 3.5 2.3 8.2 15.5 11.5 43500 26200 3.5 2.28 8.2 15.5 12 43000 28200 3.24 2.36 8.2

C35-60C C35-60C C35-60C C35-60C C35-60D

SL280UH110XV60C SLP98UH090XV48C SLP98UH090XV60C SLP98UH110XV60C SL280UH135V60D

9910882 9910883 9910884 9910885 9910886

XP16-048-230 48000 15.5 12 43000 28400 3.24 2.36 8.2 C35-60D

SLP98UH135XV60D 9910887

XP16-048-230 47000 15.5 12 41500 28000 3.46 2.58 9

C37-62C

EL180UH090E60C 10084996

XP16-048-230 47500 15 XP16-048-230 47000 15 XP16-048-230 47000 15 XP16-048-230 47000 15 XP16-048-230 47000 15

11.5 42000 28600 3.44 2.56 9 12 41500 28200 3.4 2.54 8.7 12 41500 28200 3.44 2.56 9 12 41500 28200 3.4 2.54 8.7 12 41500 28200 3.44 2.56 9

C37-62C C37-62C C37-62C C37-62C C37-62C

EL180UH110E60C EL195UH090XE48C EL195UH110XE60C EL296UH090XE48C EL296UH110XE60C

10084995 10084991 10084993 10084992 10084994

XP16-048-230 47500 16 12 45000 30000 3.44 2.62 9

CBA27UHE-048

10258588

XP16-048-230 47000 15 11.5 44500 27400 3.58 2.68 9

CBA27UHE-060

10258974

XP16-048-230 47500 15 12 44000 29400 3.48 2.56 8.5 CBX25UHV-048

7785919

XP16-048-230 48500 XP16-048-230 47500 XP16-048-230 48000 XP16-048-230 48000 XP16-048-230 48500

16 12.5 45000 29800 3.4 2.64 9 15.5 11.5 44500 27200 3.58 2.54 9 15.5 12 45500 30200 3.32 2.58 8.7 16 12.5 45500 30000 3.38 2.62 8.5 16 12.5 45000 30800 3.56 2.72 9.5

CBX27UH-048 CBX27UH-060 CBX32M-048 CBX32MV-048 CBX32MV-060

7785916 7785972 7785973 7785968 7785913

XP16-048-230 48000 16 12.5 41000 26600 3.36 2.46 8.5 CBX32MV-068

7785962

XP16-048-230 48000 16 12.5 45500 30000 3.38 2.6 8.5 CBX40UHV-048

7785969

XP16-048-230 48500 16 XP16-048-230 48500 16 XP16-048-230 48500 16 XP16-048-230 48500 16 XP16-048-230 48500 16

12.5 45000 31000 3.6 2.76 9.5 12.5 45000 29200 3.62 2.62 9 12.5 45000 29200 3.6 2.62 9 12 45000 29400 3.56 2.58 8.5 12 45000 29400 3.58 2.6 9

CBX40UHV-060 CH23-68 CH23-68 CH23-68 CH23-68

EL180UH090E60C EL180UH110E60C EL195UH090XE48C EL195UH110XE60C

7785970 7785921 7785923 7785971 7785950

XP16-048-230 48500 16 12 45000 29400 3.56 2.58 8.5 CH23-68

EL296UH090XE48C 7785951

XP16-048-230 48500 16 12 45000 29400 3.58 2.6 9

CH23-68

EL296UH110XE60C 7785963

XP16-048-230 48500 XP16-048-230 48500 XP16-048-230 48500 XP16-048-230 48000 XP16-048-230 48000

16 12 45000 29400 3.62 2.62 9 16 12 45000 29200 3.6 2.6 9 16 12 45500 29400 3.62 2.6 9 14.5 11.5 45500 30000 3.44 2.52 8.5 15 12 45500 31600 3.26 2.64 8.7

CH23-68 CH23-68 CH23-68 CH23-68 CH33-60D

EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D
EL296UH135XV60D

7785959 7785965 7785956 7785907 7785966

XP16-048-230 48000 15 12 45000 31400 3.22 2.64 8.7 CH33-60D

SL280UH135V60D 7785957

XP16-048-230 48500 15 12 45500 31600 3.26 2.64 8.7 CH33-60D

SLP98UH135XV60D 7785960

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 16

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-048-230 47000 15 12

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
43500 28600 3.38 2.48 8.7 CH33-62D

Furnace

AHRI Reference

EL296UH135XV60D 7785952

XP16-048-230 46500 15 12 43500 28600 3.4 2.5 8.7 CH33-62D

SL280UH135V60D 7785964

XP16-048-230 47000 15 12 43500 28800 3.38 2.5 8.7 CH33-62D

SLP98UH135XV60D 7785953

XP16-048-230 48000 XP16-048-230 48000 XP16-048-230 48000 XP16-048-230 47500 XP16-048-230 48000

15.5 11.5 43500 29600 3.12 2.34 8.2 15.5 11.5 43500 29600 3.1 2.32 8.2 15 11.5 43500 29600 3.1 2.32 8.2 15.5 11.5 43000 29200 3.04 2.28 8.2 15 11.5 43500 29600 3.1 2.32 8.2

CH35-51C CH35-51C CH35-51C CH35-51C CH35-51C

EL180UH090E60C EL180UH110E60C EL195UH110XE60C EL296UH090XE48C EL296UH110XE60C

9910888 9910889 9910890 9910891 9910893

XP16-048-230 47500 15.5 11.5 43000 29200 3.06 2.3 8.2 CH35-51C

EL296UH110XV60C 9910894

XP16-048-230 47500 15.5 12 43000 29000 3.1 2.3 8.2 CH35-51C

SL280UH090V60C 9910895

XP16-048-230 47500 XP16-048-230 47500 XP16-048-230 47500 XP16-048-230 47500 XP16-048-230 47000

15.5 12 43000 29000 3.1 2.3 8.2 15.5 11.5 43000 29200 3.04 2.28 8.2 15.5 11.5 43000 29200 3.06 2.3 8.2 16 12.5 44000 30200 3.54 2.7 9.5 15.5 12 44500 30400 3.48 2.64 9.2

CH35-51C CH35-51C CH35-51C CR33-50/60 CR33-50/60

SL280UH090XV60C SLP98UH090XV48C SLP98UH110XV60C EL180DF110E60C EL195DF090XE48C

9910896 9910897 9910898 7785925 7785967

XP16-048-230 47000 16 12 44000 30200 3.5 2.68 9

CR33-50/60

EL195DF110XE60C 7785958

XP16-048-230 47000 15.5 12 44500 30400 3.48 2.64 9.2 CR33-50/60

EL296DF090XE48C 7785961

XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000

16 12 16 12 16 12 16 12 14.5 11.5

44000 44500 44500 44500 44500

30200 30600 30400 30600 30800

3.5 2.68 9 3.48 2.64 9 3.48 2.64 9 3.48 2.64 9 3.38 2.6 9

CR33-50/60 CR33-50/60 CR33-50/60 CR33-50/60 CR33-50/60

EL296DF110XE60C EL296DF110XV60C SLP98DF090XV60C SLP98DF110XV60C

7785933 8688153 7785948 7785928 7785908

XP16-048-230 47000 16 12 44500 30400 3.48 2.64 9

CR33-60

SLP98DF090XV60C 7785944

XP16-048-230 47000 16 12 44500 30400 3.48 2.62 9

CR33-60

SLP98DF110XV60C 7785938

XP16-048-230 47000 14.5 11.5 44500 30600 3.38 2.58 9

CR33-60

7785909

XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46000 XP16-048-230 47000 XP16-048-230 47500

15.5 11.5 43000 28800 3.34 2.5 8.5 16 11.5 43500 29000 3.36 2.5 8.5 14 11 43500 29400 3.22 2.42 8.2 15.5 12 41500 28000 3.46 2.58 9 15 11.5 42000 28600 3.44 2.56 9

CX34-60D CX34-60D CX34-60D CX34-62C CX34-62C

SL280UH135V60D SLP98UH135XV60D
EL180UH090E60C EL180UH110E60C

7785934 7785937 7785912 7785920 7785922

XP16-048-230 47000 15 12 41500 28200 3.4 2.54 8.7 CX34-62C

EL195UH090XE48C 7785929

XP16-048-230 47000 15 12 41500 28200 3.44 2.56 9

CX34-62C

EL195UH110XE60C 7785954

XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000

15 12 41500 28200 3.4 2.54 8.7 15.5 11.5 42000 28400 3.42 2.54 8.7 15.5 11.5 42000 28400 3.42 2.54 8.7 15 12 41500 28200 3.44 2.56 9 15.5 12 41500 28200 3.42 2.56 8.7

CX34-62C CX34-62C CX34-62C CX34-62C CX34-62C

EL296UH090XE48C EL296UH090XV48C EL296UH090XV60C EL296UH110XE60C EL296UH110XV48C

7785945 7785942 7785935 7785939 7785926

XP16-048-230 47000 15.5 11.5 42000 28400 3.44 2.54 8.7 CX34-62C

EL296UH110XV60C 7785949

XP16-048-230 47000 15.5 12 41500 28200 3.46 2.58 9

CX34-62C

SL280UH090V60C 7785930

XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000

15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 11.5 42000 28200 3.44 2.54 8.7 15 11.5 42000 28200 3.46 2.54 8.7

CX34-62C CX34-62C CX34-62C CX34-62C CX34-62C

SL280UH090XV60C SL280UH110V60C SL280UH110XV60C SLP98UH090XV48C SLP98UH090XV60C

7785955 7785946 7785940 7785943 7785936

XP16-048-230 47000 15.5 11.5 42000 28400 3.44 2.54 8.7 CX34-62C

SLP98UH110XV60C 7785927

XP16-048-230 46500 14 11 42000 28800 3.32 2.5 8.5 CX34-62C

7785911

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 17

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-048-230 48500 16 12

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
43000 27600 3.42 2.44 8.5 CX34-62D

Furnace

AHRI Reference

EL296UH135XV60D 7785947

XP16-048-230 48000 16 12 42500 27600 3.4 2.46 8.5 CX34-62D

SL280UH135V60D 7785941

XP16-048-230 48500 16 12 43000 27800 3.44 2.46 8.5 CX34-62D

SLP98UH135XV60D 7785932

XP16-048-230 48000 15 XP16-048-230 46500 15 XP16-048-230 47000 15 XP16-048-230 46500 15 XP16-048-230 46500 15

11.5 43000 28200 3.28 2.4 8.2 11.5 42000 28000 3.22 2.36 8.2 11.5 42500 28600 3.22 2.36 8.2 11.5 42000 28000 3.2 2.34 8.2 11.5 42500 28400 3.2 2.34 8.2

CX34-62D CX35-49C CX35-49C CX35-49C CX35-49C

EL180UH090E60C EL180UH110E60C EL195UH110XE60C EL296UH090XV48C

7785910 9910899 9910900 9910901 9910902

XP16-048-230 46500 15 11.5 42500 28400 3.2 2.34 8.2 CX35-49C

EL296UH090XV60C 9910903

XP16-048-230 46500 15 11.5 42000 28000 3.2 2.34 8.2 CX35-49C

EL296UH110XE60C 9910905

XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500 XP16-048-230 46500

15 11.5 42000 28200 3.18 2.36 8.2 15 11.5 42500 28200 3.22 2.34 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2 15.5 11.5 42000 28000 3.22 2.36 8.2

CX35-49C CX35-49C CX35-49C CX35-49C CX35-49C

EL296UH110XV48C EL296UH110XV60C SL280UH090V60C SL280UH090XV60C SL280UH110V60C

9910904 9910906 9910907 9910908 9910909

XP16-048-230 46500 15.5 11.5 42000 28000 3.22 2.36 8.2 CX35-49C

SL280UH110XV60C 9910910

XP16-048-230 46500 15 11.5 42000 28200 3.18 2.34 8.2 CX35-49C

SLP98UH090XV48C 9910911

XP16-048-230 47000 XP16-048-230 47500 XP16-048-230 46500 XP16-048-230 47000 XP16-048-230 46500

15.5 12 43000 26000 3.52 2.32 8.2 15.5 11.5 44000 26600 3.54 2.32 8.2 15 11.5 43500 26200 3.5 2.3 8.2 15.5 11.5 43500 26000 3.52 2.3 8.2 15 11.5 43500 26200 3.5 2.3 8.2

CX35-60C CX35-60C CX35-60C CX35-60C CX35-60C

EL180UH090E60C EL180UH110E60C EL195UH090XE48C EL195UH110XE60C EL296UH090XE48C

9910912 9910913 9910914 9910915 9910916

XP16-048-230 47000 15.5 11.5 44000 26400 3.52 2.28 8.2 CX35-60C

EL296UH090XV48C 9910917

XP16-048-230 47000 15.5 11.5 44000 26400 3.52 2.28 8.2 CX35-60C

EL296UH090XV60C 9910918

XP16-048-230 47000 15.5 11.5 43500 26000 3.52 2.3 8.2 CX35-60C

EL296UH110XE60C 9910920

XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000

15.5 11.5 43500 26200 3.52 2.3 8.2 15.5 11.5 43500 26200 3.5 2.28 8.2 15.5 11.5 43500 26000 3.54 2.32 8.2 15.5 11.5 43500 26000 3.54 2.32 8.2 15.5 11.5 43500 26000 3.54 2.32 8.2

CX35-60C CX35-60C CX35-60C CX35-60C CX35-60C

EL296UH110XV48C EL296UH110XV60C SL280UH090V60C SL280UH090XV60C SL280UH110V60C

9910919 9910921 9910922 9910923 9910924

XP16-048-230 47000 15.5 11.5 43500 26000 3.54 2.32 8.2 CX35-60C

SL280UH110XV60C 9910925

XP16-048-230 47000 15.5 11.5 43500 26200 3.5 2.3 8.2 CX35-60C

SLP98UH090XV48C 9910926

XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47500 XP16-048-230 48000 XP16-048-230 46500

15.5 11.5 43500 26200 3.5 2.3 8.2 15.5 11.5 43500 26200 3.5 2.28 8.2 15.5 12 43000 28200 3.24 2.36 8.2 15.5 12 43000 28400 3.24 2.36 8.2 15.5 11.5 43000 28800 3.34 2.5 8.5

CX35-60C CX35-60C CX35-60D CX35-60D CX38-60D

SLP98UH090XV60C SLP98UH110XV60C SL280UH135V60D SLP98UH135XV60D SL280UH135V60D

9910927 9910928 9910929 9910930 10086733

XP16-048-230 46500 16 11.5 43500 29000 3.36 2.5 8.5 CX38-60D

SLP98UH135XV60D 10086735

XP16-048-230 46000 14 11 43500 29400 3.22 2.42 8.2 CX38-60D

10086667

XP16-048-230 47000 XP16-048-230 47500 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000

15.5 12 41500 28000 3.46 2.58 9 15 11.5 42000 28600 3.44 2.56 9 15 12 41500 28200 3.4 2.54 8.7 15 12 41500 28200 3.44 2.56 9 15 12 41500 28200 3.4 2.54 8.7

CX38-62C CX38-62C CX38-62C CX38-62C CX38-62C

EL180UH090E60C EL180UH110E60C EL195UH090XE48C EL195UH110XE60C EL296UH090XE48C

10086727 10086728 10086731 10086743 10086740

XP16-048-230 47000 15.5 11.5 42000 28400 3.42 2.54 8.7 CX38-62C

EL296UH090XV48C 10086738

XP16-048-230 47000 15.5 11.5 42000 28400 3.42 2.54 8.7 CX38-62C

EL296UH090XV60C 10086902

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 18

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-048-230 47000 15 12

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler

41500 28200 3.44 2.56 9

CX38-62C

Furnace

AHRI Reference

EL296UH110XE60C 10086736

XP16-048-230 47000 15.5 12 41500 28200 3.42 2.56 8.7 CX38-62C

EL296UH110XV48C 10086729

XP16-048-230 47000 15.5 11.5 42000 28400 3.44 2.54 8.7 CX38-62C

EL296UH110XV60C 10086742

XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000 XP16-048-230 47000

15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 12 41500 28200 3.46 2.58 9 15.5 11.5 42000 28200 3.44 2.54 8.7

CX38-62C CX38-62C CX38-62C CX38-62C CX38-62C

SL280UH090V60C SL280UH090XV60C SL280UH110V60C SL280UH110XV60C SLP98UH090XV48C

10086732 10086744 10086741 10086737 10086739

XP16-048-230 47000 15 11.5 42000 28200 3.46 2.54 8.7 CX38-62C

SLP98UH090XV60C 10086734

XP16-048-230 47000 15.5 11.5 42000 28400 3.44 2.54 8.7 CX38-62C

SLP98UH110XV60C 10086730

XP16-048-230 46500 14 XP16-048-230 48500 16 XP16-048-230 48000 16 XP16-048-230 48500 16 XP16-048-230 48000 15

11 42000 28800 3.32 2.5 8.5 12 43000 27600 3.42 2.44 8.5 12 42500 27600 3.4 2.46 8.5 12 43000 27800 3.44 2.46 8.5 11.5 43000 28200 3.28 2.4 8.2

CX38-62C CX38-62D CX38-62D CX38-62D CX38-62D

EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D

10086666 10084999 10084998 10084997 10084113

XP16-060-230 58500 15.7 12.2 53000 34800 3.22 2.38 8.5 C33-62D

EL180UH135E60D 7785992

XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 C33-62D

EL195UH135XE60D 7785987

XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 57000

15.2 11.5 53000 35200 3.18 2.36 8.2 15.7 12 53000 34800 3.22 2.38 8.5 15.7 12 53000 35000 3.2 2.38 8.5 15.7 12 53000 34800 3.22 2.38 8.5 14.5 11.5 53000 35000 3.16 2.36 8.2

C33-62D C33-62D C33-62D C33-62D C33-62D

EL296UH135XE60D EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D

7785985 7785990 7785994 7786000 7785977

XP16-060-230 58500 15.7 12.2 53000 34800 3.22 2.38 8.5 C37-62D

EL180UH135E60D 10085007

XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 C37-62D

EL195UH135XE60D 10085003

XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 C37-62D

EL296UH135XE60D 10085001

XP16-060-230 58500 XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 57000 XP16-060-230 57000

15.7 12 15.7 12 15.7 12 14.5 11.5 14.5 11.5

53000 53000 53000 53000 56000

34800 35000 34800 35000 34400

3.22 2.38 8.5 3.2 2.38 8.5 3.22 2.38 8.5 3.16 2.36 8.2 3.44 2.48 8.5

C37-62D C37-62D C37-62D C37-62D CBA27UHE-060

EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D

10085005 10085009 10085011 10084115 10258975

XP16-060-230 57000 15 11.5 53500 35400 3.24 2.44 8.2 CBX25UHV-060

7785988

XP16-060-230 58000 15.5 12 56500 34400 3.62 2.52 8.5 CBX27UH-060

7785978

XP16-060-230 57000 XP16-060-230 57000 XP16-060-230 58000 XP16-060-230 57000 XP16-060-230 58500

14.5 11.5 56000 36200 3.32 2.46 8.5 15.7 12 55500 35800 3.34 2.48 8.5 15.7 12.2 55500 34000 3.38 2.42 8.2 15.5 11.5 56000 36000 3.36 2.46 8.5 15.5 11.5 61000 37400 3.48 2.44 8.5

CBX32M-060 CBX32MV-060 CBX32MV-068 CBX40UHV-060 CH23-68

EL180UH135E60D

7785980 7785979 7785982 7785981 7785983

XP16-060-230 58500 15.2 11.5 61500 37600 3.44 2.4 8.5 CH23-68

EL195UH135XE60D 7786017

XP16-060-230 58500 15.2 11.5 61500 37600 3.44 2.4 8.5 CH23-68

EL296UH135XE60D 7786015

XP16-060-230 59000 XP16-060-230 58500 XP16-060-230 59000 XP16-060-230 58500 XP16-060-230 54500

15.5 11.5 61500 37600 3.46 2.42 8.5 15.7 11.5 61000 37400 3.46 2.42 8.5 15.5 11.5 61500 37600 3.46 2.42 8.5 14.5 11.5 61500 37800 3.42 2.4 8.2 15.7 11.5 52500 34600 3.14 2.34 8.2

CH23-68 CH23-68 CH23-68 CH23-68 CH33-62D

EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D
EL180UH135E60D

7786013 7786012 7786014 7785974 7786008

XP16-060-230 54500 15.2 11 53000 35000 3.1 2.32 8.2 CH33-62D

EL195UH135XE60D 7786007

XP16-060-230 54500 15.2 11 53000 35000 3.1 2.32 8.2 CH33-62D

EL296UH135XE60D 7786016

NOTES:
All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).
To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 19

AHRI SYSTEM MATCHES

Model No.

Cooling Capacity

SEER

EER

XP16-060-230 54500 15.5 11

Heat Capacity Heat COP HSPF Coil or High Low High Low (IV) Air Handler
53000 34800 3.14 2.32 8.2 CH33-62D

Furnace

AHRI Reference

EL296UH135XV60D 7786002

XP16-060-230 54500 15.7 11 53000 34800 3.14 2.32 8.2 CH33-62D

SL280UH135V60D 7786010

XP16-060-230 54500 15.5 11 53000 34800 3.14 2.32 8.2 CH33-62D

SLP98UH135XV60D 7786011

XP16-060-230 57500 XP16-060-230 57000 XP16-060-230 56500 XP16-060-230 57000 XP16-060-230 56500

15.2 12 57500 37200 3.28 2.46 8.5 15 12 57000 37200 3.18 2.44 8.2 15 11.5 57000 37400 3.14 2.42 8.2 15 12 57000 37200 3.18 2.44 8.2 15 11.5 57000 37400 3.14 2.42 8.2

CR33-50/60 CR33-50/60 CR33-50/60 CR33-50/60 CR33-50/60

EL180DF110E60C EL195DF110XE60C EL296DF090XV60C EL296DF110XE60C EL296DF110XV60C

7786006 7785997 7785998 7785995 7785996

XP16-060-230 57000 15.2 11.5 57500 37400 3.24 2.46 8.5 CR33-50/60

SL280DF090V60C 7786004

XP16-060-230 57000 15.2 12 57500 37200 3.24 2.46 8.5 CR33-50/60

SL280DF110V60C 7786018

XP16-060-230 56500 XP16-060-230 56500 XP16-060-230 56500 XP16-060-230 56500 XP16-060-230 57000

15 11.5 57000 37400 3.14 2.42 8.2 15 11.5 57000 37400 3.14 2.42 8.2 15 11.5 57000 37400 3.14 2.42 8.2 15 11.5 57000 37400 3.14 2.42 8.2 14.2 11.5 57500 37600 3.16 2.4 8.2

CR33-50/60 CR33-50/60 CR33-60 CR33-60 CR33-60

SLP98DF090XV60C SLP98DF110XV60C EL296DF110XV60C SLP98DF110XV60C

7786003 7786001 7786005 7786009 7785975

XP16-060-230 58500 15.7 12.2 53000 34800 3.22 2.38 8.5 CX34-62D

EL180UH135E60D 7785991

XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 CX34-62D

EL195UH135XE60D 7785986

XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 58000 XP16-060-230 58500 XP16-060-230 57000

15.2 11.5 53000 35200 3.18 2.36 8.2 15.7 12 53000 34800 3.22 2.38 8.5 15.7 12 53000 35000 3.2 2.38 8.5 15.7 12 53000 34800 3.22 2.38 8.5 14.5 11.5 53000 35000 3.16 2.36 8.2

CX34-62D CX34-62D CX34-62D CX34-62D CX34-62D

EL296UH135XE60D EL296UH135XV60D SL280UH135V60D SLP98UH135XV60D

7785984 7785989 7785993 7785999 7785976

XP16-060-230 58500 15.7 12.2 53000 34800 3.22 2.38 8.5 CX38-62D

EL180UH135E60D 10085006

XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 CX38-62D

EL195UH135XE60D 10085002

XP16-060-230 58000 15.2 11.5 53000 35200 3.18 2.36 8.2 CX38-62D

EL296UH135XE60D 10085000

XP16-060-230 58500 15.7 12 53000 34800 3.22 2.38 8.5 CX38-62D

EL296UH135XV60D 10085004

XP16-060-230 58000 15.7 12 53000 35000 3.2 2.38 8.5 CX38-62D

SL280UH135V60D 10085008

XP16-060-230 58500 15.7 12 53000 34800 3.22 2.38 8.5 CX38-62D

SLP98UH135XV60D 10085010

XP16-060-230 57000 14.5 11.5 53000 35000 3.16 2.36 8.2 CX38-62D

10084114

NOTES:

All matches with EL195E and ML180E gas furnaces require the use of a Blower Motor Relay Kit (85W66) for proper unit operation.

Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); · Cooling Ratings - 95°F outdoor air temperature and 80°F db/67°F wb entering indoor coil air. · High Temperature Heating Ratings - 47°F db/43°F wb outdoor air temperature and 70°F db entering indoor coil air. · Low Temperature Heating Ratings - 17°F db/15°F wb outdoor air temperature and 70°F db entering indoor coil air.

All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.

Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.

When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used (ordered extra).

To convert HSPF from Region IV to Region V - Divide by 1.15.

XP16 - 2 to 5 Ton Heat Pump / Page 20

REVISIONS
Sections AHRI System Matches

Description of Change Updated

Visit us at www.lennox.com For the latest technical information, www.LennoxPROs.com Contact us at 1-800-4-LENNOX

NOTE - Due to Lennox' ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.

Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.

Installation and service must be performed by a qualified installer and servicing agency.

©2017 Lennox Industries, Inc.


Adobe PDF Library 10.0.1