100L1 24 VDC Power Supply PAGE 1 OF 2

100L1 24 VDC Power Supply PAGE 1 OF 2 Installation Guide for PN 01895-100L NEC Class Output 1. Tools required: Wire strippers, drill, and screwdriver. 2. Supplies required: Conduit and

100L1 (Non-dimmable)

100L1 Power Supplies - 24 VDC - Refrigerated Display | SloanLED

Not Your Device? Search For Manuals / Datasheets:

File Info : application/pdf, 2 Pages, 691.33KB

Document
InstallGuide-PowerSupply-100L1
100L1 24 VDC Power Supply
Installation Guide for PN 701895-100L1 ­ NEC Class 2 Output

24 VDC Output (Red & Black)

PAGE 1 OF 2

1. Tools required: Wire strippers, drill, and screwdriver.

2. Supplies required: Conduit and electrical enclosure for power supply (if not placed in a sign made from enclosure rated material), #8 pan head screws, UL Listed PLTC cable, UL Listed electrical wire connectors (e.g., wirenuts), silicone. Europe: Electrical enclosure for power supply, M4 pan head screws, PLTC cable, silicone, 3MTM ScotchlokTMconnectors.

Mounting Tabs Primary Wires (Black & White)
3. Power Supply: Identify primary wires, secondary wires, and location of mounting tabs.

4. Mount Power Supplies: Use mounting tab in corner to secure power supply.

NOTE: Ensure adequate ventilation. Power supply operating ambient temperature is -40º to 55º C. Power supply must be mounted in an enclosure (i.e., transformer can/raceway). Power supply spacing to thermoplastic, wood, fiber, or other combustible type enclosure materials shall be 1" (25 mm). Two or more adjacent power supplies shall not be mounted closer than 1" (25 mm) end to end or 4" (102 mm) side to side. If mounted inside a sign cabinet, UL requires that cabinet is made from an enclosure rated material. Ensure power supplies are not overloaded by verifying output current is less than 4.15 DC Amps. It is recommended to use photocells or light sensors to prolong life of power supply and to keep unit at maximum operating efficiency.

5. Connect Primary: CAUTION: Have a licensed electrician connect primary. ATTENTION: Avoir un permis électricien connecter primaire.

100L1 24 VDC Power Supply
Installation Guide for PN 701895-100L1 ­ NEC Class 2 Output
TROUBLESHOOTING If sign is not functioning properly, check the following: · Primary voltage is between 120-277 VAC · Secondary voltage is 24 VDC · Output current is 4.15 Amps or less · Power supply is not overloaded (see power supply capacity chart in product installation guide or SloanLED.com) · There are no shorts in secondary wiring · All secondary connections are RED-TO-RED and BLACK-TO-BLACK
SloanLED products carry a limited warranty. For complete details refer to the warranty policy found at SloanLED.com

E336107 4ZG6

E215393

Some or all of the products shown are covered by U.S. and foreign patents pending and covered by one of more of the following U.S. patents issued:

6776504, 6969179, 7192157, 6932495, 7241031

Customer service and technical support SloanLED Headquarters 5725 Olivas Park Drive, Ventura, CA, USA 888.747.4LED (888.747.4533) · [email protected]
SloanLED.com

SloanLED Europe b.v. Argonstraat 110, 2718 SN Zoetermeer, NL +31 88 12 44 900 · [email protected]

P/N 402794 Rev A 2021-03-24

PAGE 2 OF 2



References

Adobe PDF Library 15.0