Motorola Mobility LLC T56AR2 Mobile Cellular Phone IHDT56AR2 IHDT56AR2 t56ar2
FCC RF Test Report Report No. : 381718 Spot Check Evaluation APPLICANT EQUIPMENT BRAND NAME MODEL NAME FCC ID STANDARD : Motorola Mobility LLC : Mobile Cellular Phone : Motorola : XT2421-3 : IHDT56AR2 : 47 CFR Part 2, 27(M) 47 CFR Part 15 Subpart C §15.247 47 CFR Part 15 Subpart E §15.407 We, Sporton International Inc. (Kunshan), would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards. The test results in this report apply exclusively to the tested model / sample. Without written approval of Sporton International Inc. (Kunshan), the test report shall not be reproduced except in full. Approved by: Jason Jia Sporton International Inc. (Kunshan) No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People's Republic of China Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 1 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 381718 TABLE OF CONTENTS REVISION HISTORY..........................................................................................................................................3 1 GENERAL DESCRIPTION..........................................................................................................................4 1.1 Applicant ............................................................................................................................................ 4 1.2 Manufacturer......................................................................................................................................4 1.3 Product Feature of Equipment Under Test........................................................................................4 1.4 Modification of EUT ........................................................................................................................... 4 1.5 Testing Site ........................................................................................................................................ 4 1.6 Test Software.....................................................................................................................................5 1.7 Applicable Standards.........................................................................................................................5 1.8 Specification of Accessory.................................................................................................................6 2 RE-USE OF MEASURED DATA.................................................................................................................7 2.1 Introduction Section ........................................................................................................................... 7 2.2 Model Difference Information ............................................................................................................ 7 2.3 Reference detail Section: .................................................................................................................. 7 2.4 Spot Check Verification Data Section................................................................................................ 8 3 LIST OF MEASURING EQUIPMENT........................................................................................................10 4 MEASUREMENT UNCERTAINTY ............................................................................................................ 11 APPENDIX A. SETUP PHOTOGRAPHS Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 2 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report REVISION HISTORY REPORT NO. 381718 VERSION DESCRIPTION Rev. 01 Initial issue of report Report No. : 381718 ISSUED DATE Nov. 28, 2023 Conformity Assessment Condition: 1. The test results (PASS/FAIL) with all measurement uncertainty excluded are presented against the regulation limits or in accordance with the requirements stipulated by the applicant/manufacturer who shall bear all the risks of non-compliance that may potentially occur if measurement uncertainty is taken into account. 2. The measurement uncertainty please refer to each test result in the section "Measurement Uncertainty" Disclaimer: The product specifications of the EUT presented in the test report that may affect the test assessments are declared by the manufacturer who shall take full responsibility for the authenticity. Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 3 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 381718 1 General Description 1.1 Applicant Motorola Mobility LLC 222 W,Merchandise Mart Plaza, Chicago IL 60654 USA 1.2 Manufacturer Motorola Mobility LLC 222 W,Merchandise Mart Plaza, Chicago IL 60654 USA 1.3 Product Feature of Equipment Under Test Product Feature Equipment Mobile Cellular Phone Brand Name Motorola Model Name XT2421-3 FCC ID IHDT56AR2 IMEI Code Conducted: 359058510002855/359058510002863 Radiation: 359058510028157/359058510028165 HW Version DVT2 SW Version EUT Stage ULA34.53 Identical Prototype Remark: The above EUT's information was declared by manufacturer. Please refer to the specifications or user's manual for more detailed description. 1.4 Modification of EUT No modifications are made to the EUT during all test items. 1.5 Testing Site Sporton International Inc. (Kunshan) is accredited to ISO/IEC 17025:2017 by American Association for Laboratory Accreditation with Certificate Number 5145.02. Test Firm Sporton International Inc. (Kunshan) Test Site Location No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People's Republic of China TEL : +86-512-57900158 Test Site No. Sporton Site No. 03CH04-KS TH01-KS FCC Designation No. CN1257 FCC Test Firm Registration No. 314309 Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 4 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 381718 1.6 Test Software Item 1. Site TH01-KS 2. TH01-KS 3. TH01-KS 4. 03CH04-KS Manufacturer SPORTON SPORTON SPORTON AUDIX Name FCC 15C-15E Test Tools Ver10.0_210607 FCC BT2.0 Ver3.0_For_CHINA_190111 FCC LTE_Ver2.0 Auto_china_210503 E3 Version 10.0 3.0 2.0 210616 1.7 Applicable Standards According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: FCC KDB 484596 D01 Referencing Test Data v02r01 47 CFR Part 2, 27(M) 47 CFR Part 15 Subpart C §15.247 47 CFR Part 15 Subpart E §15.407 ANSI C63.10-2013 ANSI C63.26-2015 Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 5 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 381718 1.8 Specification of Accessory AC Adapter 1(US) AC Adapter 1(EU) AC Adapter 1(UK) AC Adapter 1(AU) AC Adapter 1(CHILE) AC Adapter 2(US) AC Adapter 2(EU) AC Adapter 2(UK) AC Adapter 2(AU) AC Adapter 3(US) AC Adapter 3(EU) AC Adapter 3(UK) AC Adapter 3(AU) Battery 1 Battery 2 Battery 3 Earphone 1 Earphone 2 USB Cable 1 USB Cable 2 Specification of Accessory Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Salcomp) Model Name Brand Name Motorola (Chenyang) Model Name Brand Name Motorola (Chenyang) Model Name Brand Name Motorola (Chenyang) Model Name Brand Name Motorola (Chenyang) Model Name Brand Name Motorola (Aohai) Model Name Brand Name Motorola (Aohai) Model Name Brand Name Motorola (Aohai) Model Name Brand Name Motorola (Aohai) Model Name Brand Name Motorola (ATL) Model Name Brand Name Motorola (sunwoda) Model Name Brand Name Motorola (SCUD) Model Name Brand Name Motorola (New leader) Model Name Brand Name Motorola (JWELL) Model Name Brand Name Motorola (JWELL) Model Name Brand Name Motorola (saibao) Model Name MC-101 MC-102 MC-103 MC-105 MC-109 MC-101 MC-102 MC-103 MC-105 MC-101 MC-102 MC-103 MC-105 QF50 QF50 QF50 NLD-EM313A-20SF JWEP1205-L20H JWUB1631-L20H SLQ-A238A Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 6 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 381718 2 Re-use of Measured Data 2.1 Introduction Section This application re-uses data collected on a similar device. The subject device of this application (Model: XT2421-3, FCC ID: IHDT56AR2) is electrically identical to the reference device (Model: XT2421-2, FCC ID: IHDT56AR1) for the portions of the circuitry corresponding to the data being re-used. Based on their similarity, the FCC Part 15C (equipment class: DTS, DSS) and FCC Part 15E (equipment class: NII) and FCC Part 27 (equipment class: PCE) reuse the original model's result and do spot-check, following the FCC KDB 484596 D01 Referencing Test Data v02r01. The applicant takes full responsibility that the test data as referenced in this report represent compliance for this FCC ID: IHDT56AR2 . 2.2 Model Difference Information The main difference between FCC ID: IHDT56AR1 and FCC ID: IHDT56AR2 is as below: Remove GSM1900, WCDMA II/ IV, LTE B2/4/13/26/66. Add LTE B20/41. Other differences and all the details of similarity and difference can be found in the confidential documents (XT2421-3_Operational Description of Product Equality Declaration). 2.3 Reference detail Section: Rule Equipment Part Class DSS (BR/EDR) 15C DTS (BLE) DTS (WLAN) 15E U-NII 27 PCE (LTE) Frequency Band (MHz) 2400~2483.5 2400~2483.5 2400~2483.5 5180~5240 5260~5320 5500~5700 5745~5825 B7 Reference FCC ID (Parent) IHDT56AR1 Type Grant/ Permissive Change Original Grant IHDT56AR1 Original Grant IHDT56AR1 Original Grant IHDT56AR1 Original Grant IHDT56AR1 Original Grant IHDT56AR1 Original Grant IHDT56AR1 Original Grant IHDT56AR1 Original Grant Reference Title FR381717A FR381717B FR381717C FR381717D FR381717D FZ381717 FR381717D FZ381717 FR381717D FG381717B FCC ID Filling (Variant) IHDT56AR2 IHDT56AR2 IHDT56AR2 IHDT56AR2 IHDT56AR2 IHDT56AR2 IHDT56AR2 IHDT56AR2 Report Title/Section All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable All sections applicable Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 7 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 381718 2.4 Spot Check Verification Data Section Conducted power test and radiated spurious emission test against the variant model based on the worst-case condition from the original model was performed in this filing to demonstrate the test data from original model remains representative for the variant model. All test procedures follow the related section of parent report. For any given test, the maximum identified difference between spot check and reference data shall be no larger than 25%, in linear units. |spot check data reference data| / |reference data| 0.25 where "| |" is the absolute value of the measured quantity. Summary for power and RSE spot check for each rule entry and technology is listed as below: IHDT56AR1 IHDT56AR2 Test Item Mode Parent Worst mode Variant Check Test Difference Limit Test Result Result BT BR/EDR 10.42 9.82 0.129 0.25 BLE 1M 1.05 0.98 0.016 0.25 BLE 2M 1.03 0.77 0.058 0.25 11b 20.37 20.25 0.027 0.25 11g 24.68 24.52 0.036 0.25 11n20 24.59 24.43 0.036 0.25 11a UNII-1 18.48 18.44 0.009 0.25 11a UNII-2A 18.17 17.94 0.052 0.25 Conducted 11a UNII-2C 18.53 18.41 0.027 0.25 Power 11a UNII-3 18.25 18.16 0.021 0.25 (dBm) 11n20 UNII-1 18.45 18.39 0.014 0.25 11n20 UNII-2A 18.18 17.97 0.047 0.25 11n20 UNII-2C 18.58 18.42 0.036 0.25 11n20 UNII-3 18.39 18.31 0.018 0.25 11ac20 UNII-1 17.49 17.36 0.029 0.25 11ac20 UNII-2A 17.39 17.12 0.060 0.25 11ac20 UNII-2C 17.67 17.36 0.069 0.25 11ac20 UNII-3 17.53 17.25 0.062 0.25 LTE Band 7 22.41 22.55 0.033 0.25 For example: BT BR/EDR (dBm): mW = 10^(dBm/10) Difference = |spot check data reference data| / |reference data| = |10^(9.82/10) - 10^(10.42/10)| / |10^(10.42/10)| = 0.129 Test Item Radiated Spurious Emission (dBm) Mode LTE Band 7 IHDT56AR1 Parent Worst Result -56.45 IHDT56AR2 Variant Check Result -56.95 Difference 0.109 Limit 0.25 Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 8 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 381718 Conclusion: Radiated spurious emission test against the variant model based on the worst-case condition from the original model was performed in this filing to demonstrate the test data from original model remains representative for the variant model. Based on the spot check test result, the test data from the original model is representative for the variant model. The power level and RSE spot check are shown within expected level compliant to limit line. We are using power and ERP/EIRP measurements from the original parent model reports to list on the grant. The same DFS detection is used in the variant. Hence, there is no spot check data for DFS. We confirm that the test data reuse policy of FCC KDB 484596 D01 Referencing Test Data v02r01 has been followed and the test data as referenced from the parent model report represents compliance with new FCC ID. Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 9 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 381718 3 List of Measuring Equipment Instrument Spectrum Analyzer Pulse Power Senor Power Meter Power divider EXA Spectrum Analyzer Loop Antenna Calibration Manufacturer Model No. Serial No. Characteristics Date R&S FSV40 101040 10Hz~40GHz Oct. 11, 2023 Anritsu Anritsu MA2411B ML2495A 0917070 1005002 300MHz~40GH z 50MHz Bandwidth Jan. 05, 2023 Jan. 05, 2023 STI STI08-0055 - 0.5~40GHz NCR Keysight N9010B MY574710 10Hz-44G,MAX 79 30dB Oct. 10, 2023 R&S HFH2-Z2E 101125 9kHz~30MHz Sep. 11, 2023 Bilog Antenna TeseQ CBL6111D 49922 30MHz-1GHz Apr. 09, 2023 Horn Antenna Schwarzbeck BBHA9120D 1284 1GHz~18GHz Oct. 10, 2023 SHF-EHF Horn Com-power AH-840 101070 18GHz~40GHz Jan. 08, 2023 Amplifier Amplifier high gain Amplifier Amplifier AC Power Source Turn Table SONOMA MITEQ EM Agilent Chroma ChamPro 310N 380827 EM18G40GG A 060728 EM01G18GA 060840 8449B 61601 3008A023 70 F1040900 04 EM 1000-T 060762-T 9KHz-1GHz 18~40GHz 1Ghz-18Ghz 1Ghz-18Ghz N/A 0~360 degree Jul. 06, 2023 Jan. 05, 2023 Oct. 10, 2023 Oct. 10, 2023 NCR NCR Antenna Mast ChamPro EM 1000-A 060762-A 1 m~4 m NCR Test Date Nov. 06, 2023 Nov. 06, 2023 Nov. 06, 2023 Nov. 06, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Nov. 07, 2023 Due Date Oct. 10, 2024 Jan. 04, 2024 Jan. 04, 2024 NCR Oct. 09, 2024 Sep. 10, 2024 Apr. 08, 2024 Oct. 09, 2024 Jan. 07, 2024 Jul. 05, 2024 Jan. 04, 2024 Oct. 09, 2024 Oct. 09, 2024 NCR NCR NCR Remark Conducted (TH01-KS) Conducted (TH01-KS) Conducted (TH01-KS) Conducted (TH01-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) Radiation (03CH04-KS) NCR: No Calibration Required. Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 10 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0 FCC RF Test Report Report No. : 381718 4 Measurement Uncertainty The measurement uncertainties shown below were calculated in accordance with the requirements of ANSI 63.26-2015. All the measurement uncertainty value were shown with a coverage K=2 to indicate 95% level of confidence. The measurement data show herein meets or exceeds the CISPR measurement uncertainty values specified in CISPR 16-4-2 and can be compared directly to specified limit to determine compliance. Uncertainty of Conducted Measurement Test Item Conducted Power Uncertainty ±0.46 dB Uncertainty of Radiated Emission Measurement (30 MHz ~ 1000 MHz) Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) 3.82dB Uncertainty of Radiated Emission Measurement (1 GHz ~ 18 GHz) Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) 3.56dB Uncertainty of Radiated Emission Measurement (18 GHz ~ 40 GHz) Measuring Uncertainty for a Level of Confidence of 95% (U = 2Uc(y)) 3.54dB -THE END- Sporton International Inc. (Kunshan) TEL : +86-512-57900158 Page Number : 11 of 11 Report Issued Date : Nov. 28, 2023 Report Version : Rev. 01 Report Template No.: SCE Version 1.0Microsoft Word 2010 Microsoft Word 2010