Cisco Business 110 Series Unmanaged Switches Mounting Guide

lisutera

Leggi le istruzioni

Cisco CBS110 | Confronta prezzi | Trovaprezzi.it

PDF preview unavailable. Download the PDF instead.

cisco cbs110 8t d
Questo manuale d'istruzione è fornito da trovaprezzi.it. Scopri tutte le offerte per Cisco CBS110 CBS110-8T-D o cerca il tuo prodotto tra le migliori offerte di Switch
Quick Start Guide
Cisco 110 Series Unmanaged Switches

Unbox 2

239954

110 Series Unmanaged Switches

Rack-mount (Optional) - Size 1
1
2

Lorem ipsum

4m4.m45

m10m1

50 mm

3

391444

110 Series Unmanaged Switches

3

Rack-mount (Optional) - Size 2
1 2
4

4m3m.2

2m1m.3

70 mm

3

391445

110 Series Unmanaged Switches

Rack-mounting SG110-24 and SG110-24HP
1 2
110 Series Unmanaged Switches

4m4.m45

2m1m.3

65 mm

3

391446

5

Rack-mounting SG112-24
1 2
6

4m4.m45

1m01m.6

65 mm

3

391447

110 Series Unmanaged Switches

Safety Instructions for Rack Mounting

Safety Instructions - Rack Mount

The following or similar rack-mount instructions are included with the installation instructions.
A) Elevated Operating Ambient - If installed in a closed or multi-rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in the rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
C) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
D) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing these concerns.
E) Reliable Earthing - Reliable Earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch current (e.g. use of power strips)."

110 Series Unmanaged Switches

7

Wall-mount (Optional)

X.XX

X.XX

239959

X.XX=
SG110D-05, SF110D-05 SF110D-08/08HP/16/16HP, SG110D-08/08HP SF110-16/24, SG110-16/16HP
8

1.7 in/43 mm 2.5 in/63 mm 3.7 in/94 mm

110 Series Unmanaged Switches

Wall-mount if needed (continued)
1

2

SF110D-05/08, SG110D-05, SF110D-16/16HP

1=0.3 in/7.6 mm

2=0.6 in/15 mm

SF110D-08HP, SG110D-08/08HP

1=0.3 in/7.7 mm

2=0.85 in/21.8 mm

SF110-16/24, SG110-16/16HP

1=0.31 in/8 mm

2=0.87 in/22.2 mm

Wall Mount - Placement Options

110 Series Unmanaged Switches

3 4
3=0.17 in/4.3 mm 3=0.25 in/6.5 mm 3=0.27 in/6.8 mm

4=0.6 in/15.7 mm 4=0.68 in/17.4 mm 4=0.62 in/17.6 mm
9

196243

To install the switch, either set it on its four rubber pads and place it on a flat surface, or mount it on a wall using the wallmount slots on the bottom panel of the switch.
1

391490

To use the wall mount option, follow these steps: Step 1 : Attach two screws to the wall such that the wall-mount slots of the switch lineup with the two screws.
SF110D-05 - The screws should be 1.7 in (43 mm) apart. SF110D-08 - The screws should be 2.5 in (63.5 mm) apart. SF110D-16 - The screws should be 2.5 in (63.5 mm) apart. The wall-mount slots are two criss-cross slots on the bottom panel of the switch. Step 2: Maneuver the switch to insert the screws into the two wall-mount slots.

10

110 Series Unmanaged Switches

Power On Switch

239957

110 Series Unmanaged Switches

11

Attach Devices

239958

12

110 Series Unmanaged Switches

Ambient Temperature Ratings Switch Model
SF110D-05 SF110D-08 SF110D-08HP SF110-16 SF110D-16 SF110D-16HP SF110-24 SF112-24 SG110D-05 SG110D-08 SG110D-08HP SG110-16 SG110-16HP SG110-24

Temperature Range
32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C) 32o to 122o F (0o to 50o C)

110 Series Unmanaged Switches

13

Switch Model
SG110-24HP SG112-24

Temperature Range
32o to 113o F (0o to 45o C) 32o to 122o F (0o to 50o C)

Physical Cable Diagnostics The 110 Series Unmanaged Switches have built-in diagnostics for cables which can detect cable issues upon connection to the port. It provides network integrity and can detect loops within the network when storm conditions are discovered. For best detection accuracy, please use a minimum cable length of 10 meters (~30 feet). Cable Diagnostic Output · Physical cable fault enables amber LED continuously · Loop detection will enable periodic amber LED blinking
Procedure
STEP 1 Ensure that the switch is powered on.. STEP 2 With the suspected cable connected to the switch, look at the pertinent interface's LED outputs. A solid amber
LED indicates a cable fault or open end. A blinking amber LED indicates a loop.

14

110 Series Unmanaged Switches

For More Information
110 Series Unmanaged Switches: www.cisco.com/go/110switches Regulatory, Compliance, and Safety Information: www.cisco.com/go/110switches Click on the Resources tab, and scroll down to Technical Documentation. End User License Agreement: www.cisco.com/go/eula Warranty Information: www.cisco-warrantyfinder.com EU lot 26 related test result www.cisco.com/go/eu-lot26-results

110 Series Unmanaged Switches

15

Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA www.cisco.com Support US: 1-866-606-1866 Support, Global: www.cisco.com/go/sbsc
Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1005R) © 2021 Cisco Systems, Inc. All rights reserved.