Single Packs

Single Pack SC12CL 220-240V 50Hz CSIR

Single pack code number: 195B4084

Single Pack Components
PositionTitleCodeAmount
1Compressor SC12CL104L26231
2Starting relay117U60051
3Starting capacitor (80µF 220V, 6.3mm)117U50171
4Cord relief103N10041
5Cover103N20091
6Bolt joint for one compressor | M6 | Ø16mm118-19171

Secop GmbH

Lise-Meitner-Straße 29 • 24941 Flensburg, Germany • Tel: +49 461 49410 • www.secop.com

Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.

Secop SC12CL Compressor Technical Data

General Information

Model: SC12CL

Designation: 220-240V/50Hz 1~

Sales Code: 104L2623

Compressor Design

Compressor Design Details
Oil typePolyolester
Oil viscosity32cST
Oil quantity550cm³ / 18.6fl.oz
Refrigerant charge - tech. limit1300g / 45.9oz
Free gas volume comp.1460cm³ / 49.4fl.oz
Weight13.1kg / 28.9lbs
Motor protection1# internal
Winding resistance main5.13Ω (at 25°C)
Winding resistance aux13.51Ω (at 25°C)
Max. winding temp.125°C / 257°F
Max. discharge temp.130°C / 266°F

Diagram: Image of the Secop SC12CL compressor, showing its S-Series design.

Key Specifications:

  • Refrigerant(s): R404A, R452A, R507
  • Displacement: 12.87cm³ / 0.79cu.in
  • Compressors on pallet: 80

General - Configurations with SC12CL

General Configurations
ParameterConf. 1Conf. 2
MotorconfigurationCSIRCSIR
Power supply (nominal)220-240V/50Hz220-240V/50Hz
Number of phases11
Voltage range198-254V198-254V
ApprovalsVDE, CCC, EACVDE, CCC
Starting torqueHSTHST
Note-/--/-

Applications with SC12CL

Applications
ParameterConf. 1Conf. 2
RefrigerantR404AR452A
ApplicationLBPLBP
System coolingfan 3m/sfan 3m/s
Hot gas defrostOKOK
Long interval pull downOKOK

Electrical Data - Configurations with SC12CL

Electrical Data
ParameterConf. 1Conf. 2
Starting device typerelayrelay
Run capacitor-/--/-
Start capacitor80µF80µF
LRA (locked rotor amps / 4s)23.4A16.2A
RLA (rated load amps / 1s)4.3A3.1A
Cut in current23.4A16.2A

Compressor Dimensions

Housing Dimensions

Housing Dimensions (mm / in)
A Height209 / 8.23
B Height203 / 7.99
C Length shell218 / 8.58
D Length w. cover255 / 10.04
E Width151 / 5.94

Diagram: Outline of the compressor showing dimensions A (Height), B (Height), C (Length shell), D (Length w. cover), E (Width). Also shows reference points X, Y, Z, and angles (vertical angle, horizontal angle).

Connectors

Connector Details (Suction, Discharge, Process)
ParameterUnitSuctionDischargeProcess
Diameter (i:inside, o:outside)mmøi 8.11-8.29øi 6.11-6.29øi 6.11-6.29
inØi 0.32-0.33øi 0.24-0.25øi 0.24-0.25
Material-coppercoppercopper
Horizontal angle°37°37°143°
°+2°30°150°
Position I/h/wmm107/183/55115/100/63-107/183/55
in4.2/7.2/2.24.5/3.9/2.5-4.2/7.2/2.2
Straight tube l.mm121212
in0.50.50.5

Compressor Fixation

Baseplate Dimensions

Baseplate Dimensions (mm / in)
Labelmminch
BI2048.03
Bw1505.9
ØEØ 9.7Ø 0.38

Large Holes

Large Holes Dimensions (mm / in)
Labelmminch
LI1656.5
Lw101.64
ØLØ 19Ø 0.75

Small Holes

Small Holes Dimensions (mm / in)
Labelmminch
SI1706.7
Sw702.76
ØSØ 16Ø 0.63
QI1275
Qw1275

Diagram: Shows compressor fixation points labeled ØS, ØL, SI, Sw, BI, Bw, ØE, QI, Qw. Includes detailed dimensions for baseplate, large holes, and small holes.

Mounting Accessories

Mounting Accessories
Accessory TypePart Number (one comp.)Part Number (multi pack)
Bolt joint | M6 | Ø16mm118-1917118-1918
Bolt joint | Ø1/4" | Ø16mm118-1946118-1919
Bolt joint | Ø1/4" | Ø19mm118-1949-
Snap-on | Ø7.3 | Ø16mm118-1947-

Diagram: Illustrates a "Bolt joint" assembly with components: Washer, Compressor base, Nut, Sleeve, Cabinet base, Bolt, Rubber grommet. Also illustrates a "Snap-on" assembly with components: Washer, Compressor base, Clip, Steel pin, Cabinet base, Rubber grommet.

Application Notes: Provision for PE Grounding is located at the PE Stamp on the compressor.

Ambient/Machine Room Temperatures

Ambient temperature range: 10 - 38°C / 50 - 101°F

Machine room temperature range: 10 - 43°C / 50 - 110°F

Compressor cooling: fan 3m/s

Operation Limits

Diagram: Electrical accessories / wiring diagram for CSIR configuration. Shows compressor components (a2 relay, c start capacitor, d cord relief, b plastic cover) and their connections to the main winding and start winding, including a winding protector.

Operation Pressure Range

Graph: Operation pressure range plot. X-axis: Evaporation pressure (sat. temp.) in bars (0-22). Y-axis: Condensing pressure (sat. temp.) in bars (50-170). Shows curves for "continuous operation" and "transitory operation". Temperature scales (°C: -50 to 102, °F: -58 to 102) are provided.

Evaporation Pressure

Graph: Evaporation pressure plot. X-axis: Evaporation pressure [bars] (0-22). Y-axis: Condensing pressure [bars] (0-35). Shows curves for "continuous operation" and "transitory operation".

Components List

Electrical Components
ComponentPart Number
a2 relay117U6005
c start capacitor (80µF)117U5017
d cord relief103N1004
b plastic cover103N2009

Optimization + Standard Conditions

Conditions: R404A, 220V/50Hz, CSIR, fan 3m/s, VDE, CCC, EAC

Optimization + Standard Conditions (R404A)
Evaporating Pressure (pe)Condensing Pressure (pc)Return Gas Temp. (RGT)Liquid Temp. (Tliq)Cooling CapacityCOP
(W/W)
EERPower Consumption P1
(W)
Current Consumption I
(A)
Ref. mass flow m
(kg/h)
Standard
[W][Btu/h][kcal/h][Btu/Wh][kcal/Wh]
-23°C / -10°F54°C / 130°F32°C / 90°F32°C / 90°F514.51757442.81.103.750.94468.92.8911.99ASHRAE LBP
-25°C / -13°F55°C / 131°F32°C / 90°F55°C / 131°F335.91147289.10.762.590.65443.02.8010.50cecomaf LBP
-35°C / -31°F40°C / 104°F20°C / 68°F40°C / 104°F279.2953240.20.872.970.75321.52.437.59EN12900 LBP
-23°C / -10°F49°C / 120°F4.4°C / 40°F49°C / 120°F410.01400352.90.882.990.75468.32.9114.52ARI540 LBP
-23°C / -10°F41°C / 105°F32°C / 90°F32°C / 90°F665.52273572.71.444.921.24461.82.8715.51AHAM LBP
-35°C / -31°F45°C / 113°F32°C / 90°F45°C / 113°F238.8816205.50.762.590.65315.32.436.38opt

Performance Tables

Conditions: R404A, 220V/50Hz, CSIR, fan 3m/s, VDE, CCC, EAC

Performance Table 1 (R404A)
ConditionsCooling CapacityCOP
(W/W)
EERPower Consumption P1
(W)
Current Consumption I
(A)
Ref. mass flow m
(kg/h)
[W][Btu/h][kcal/h][Btu/Wh][kcal/Wh]
Evap. Pressure (pe)
-45°C / -49°F78.426867.50.411.400.35191.62.152.08
-35°C / -31°F238.8816205.50.762.590.65315.32.436.38
-30°C / -22°F350.61197301.70.933.160.80378.72.619.41
-25°C / -13°F485.61659417.91.093.740.94443.82.8213.10
-20°C / -4°F645.62205555.61.264.311.09511.13.0617.52
-15°C / 5°F832.22842716.21.434.891.23581.03.3422.73
-5°C / 23°F1291.844121111.81.776.041.52730.53.9735.91
Cond. Pressure (pc)
pc= 45/113
Return Gas Temp. (RGT)
RGT= 32/90
Liquid Temp. (Tliq)
Tliq= 45/113
Evap. Pressure (pe)
-45°C / -49°F22.27619.10.150.510.13148.01.980.68
-35°C / -31°F138.7474119.30.471.620.41293.12.334.29
-30°C / -22°F226.3773194.80.622.110.53367.22.557.03
-25°C / -13°F335.91147289.10.762.590.65443.02.8010.50
-20°C / -4°F468.91601403.50.903.070.77520.93.0814.75
-15°C / 5°F627.12142539.71.043.560.90601.33.3919.89
-5°C / 23°F1025.73503882.71.334.541.14771.94.0933.20

Configuration 2: Operation Limits & Wiring

Configuration: Conf. 2

Refrigerant: R452A

Ambient temperature range: 10 - 38°C / 50 - 101°F

Machine room temperature range: 10 - 43°C / 50 - 110°F

Compressor cooling: fan 3m/s

Diagram: Electrical accessories / wiring diagram for CSIR configuration. Shows compressor components (a2 relay, c start capacitor, d cord relief, b plastic cover) and their connections to the main winding and start winding, including a winding protector.

Operation Pressure Range

Graph: Operation pressure range plot. X-axis: Evaporation pressure (sat. temp.) in bars (0-20). Y-axis: Condensing pressure (sat. temp.) in bars (50-170). Shows curves for "continuous operation" and "transitory operation". Temperature scales (°C: -50 to 40, °F: -58 to 102) are provided.

Evaporation Pressure

Graph: Evaporation pressure plot. X-axis: Evaporation pressure [bars] (0-20). Y-axis: Condensing pressure [bars] (0-30). Shows curves for "continuous operation" and "transitory operation".

Components List

Electrical Components
ComponentPart Number
a2 relay117U6005
c start capacitor (80µF)117U5017
d cord relief103N1004
b plastic cover103N2009

Optimization + Standard Conditions (R452A)

Conditions: R452A, 220V/50Hz, CSIR, fan 3m/s, VDE, CCC

Optimization + Standard Conditions (R452A)
Evaporating Pressure (pe)Condensing Pressure (pc)Return Gas Temp. (RGT)Liquid Temp. (Tliq)Cooling CapacityCOP
(W/W)
EERPower Consumption P1
(W)
Current Consumption I
(A)
Ref. mass flow m
(kg/h)
Standard
[W][Btu/h][kcal/h][Btu/Wh][kcal/Wh]
-23°C / -10°F54°C / 130°F32°C / 90°F32°C / 90°F463.81584399.11.073.660.92432.32.8711.15ASHRAE LBP
-25°C / -13°F55°C / 131°F32°C / 90°F55°C / 131°F304.61040262.20.752.560.64406.72.789.69cecomaf LBP
-35°C / -31°F40°C / 104°F20°C / 68°F40°C / 104°F246.2841211.90.842.870.72293.12.376.88EN12900 LBP
-23°C / -10°F49°C / 120°F4.4°C / 40°F49°C / 120°F376.31285323.90.872.960.75433.72.8813.53ARI540 LBP
-23°C / -10°F41°C / 105°F32°C / 90°F32°C / 90°F607.32074522.71.414.821.21430.42.8714.60AHAM LBP
-35°C / -31°F45°C / 113°F32°C / 90°F45°C / 113°F208.6712179.50.732.490.63285.62.355.73opt

Performance Tables (R452A)

Conditions: R452A, 220V/50Hz, CSIR, fan 3m/s, VDE, CCC

Performance Table 2 (R452A)
ConditionsCooling CapacityCOP
(W/W)
EERPower Consumption P1
(W)
Current Consumption I
(A)
Ref. mass flow m
(kg/h)
[W][Btu/h][kcal/h][Btu/Wh][kcal/Wh]
Evap. Pressure (pe)
-45°C / -49°F60.420652.00.361.220.31168.51.921.65
-35°C / -31°F208.6712179.50.732.490.63285.62.355.73
-30°C / -22°F313.81072270.00.903.090.78347.12.578.64
-25°C / -13°F442.01509380.41.083.670.93410.92.8012.23
-20°C / -4°F595.02032512.11.254.261.07477.53.0416.55
-15°C / 5°F774.82646666.81.424.841.22547.13.2921.67
-5°C / 23°F1221.441711051.11.755.991.51696.93.8334.71
Cond. Pressure (pc)
pc= 45/113
Return Gas Temp. (RGT)
RGT= 32/90
Liquid Temp. (Tliq)
Tliq= 45/113
Evap. Pressure (pe)
-45°C / -49°F15.45313.20.120.410.10126.71.770.48
-35°C / -31°F119.7409103.00.461.560.39262.02.263.77
-30°C / -22°F201.2687173.10.602.060.52333.02.526.37
-25°C / -13°F304.61040262.20.752.560.64406.72.789.69
-20°C / -4°F431.81475371.60.893.050.77483.43.0613.82
-15°C / 5°F584.61996503.11.043.540.89563.43.3518.84
-5°C / 23°F973.83326838.11.334.531.14734.93.9631.96

SC Compressors - Diagrams and Service Information

Diagram: General outline of SC Compressors with reference numbers (e.g., 8238-22).

Diagrams: Exploded views of compressor components and assembly, showing electrical connections and accessories (e.g., 8221-2, 8222-2, 8227-2).

Diagram: Wiring schematic for SC Compressors, illustrating main winding, start winding, and winding protector connections.

Diagram: Electrical accessories and wiring diagram for CSIR configuration, showing components like relay (a2), start capacitor (c), cord relief (d), and plastic cover (b).

Service/Repair - R290

Warning Symbol: A triangular warning symbol indicating flammable refrigerant R290.

Diagram: Illustrates correct and incorrect procedures for connecting/disconnecting refrigerant lines, using tools. A checkmark (✔️) indicates correct procedure, and a cross (❌) indicates incorrect procedure.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4084 GPL Ghostscript 10.05.1

Related Documents

PreviewSECOP SC15CL Compressor Technical Data
Detailed technical specifications and performance data for the SECOP SC15CL compressor, including electrical data, operating ranges, and performance tables for various refrigerants and conditions.
PreviewSECOP NLE10CN Compressor Technical Data
Detailed technical specifications and performance data for the SECOP NLE10CN compressor, designed for R290 refrigerant and 220-240V/50Hz operation. Includes dimensions, electrical data, operating ranges, and performance tables.
PreviewSecop SC18CLX.2 Compressor Technical Data Sheet
Comprehensive technical specifications, performance data, dimensions, and electrical information for the Secop SC18CLX.2 compressor, suitable for 220-240V, 50Hz, CSIR applications. Includes optimization conditions and performance tables.
PreviewSecop NL8.4FT Compressor Technical Data, Specifications, and Performance
Comprehensive technical specifications, dimensions, performance data, configuration details (CSIR/RSIR), and electrical information for the Secop NL8.4FT compressor (220-240V, 50Hz). Includes single pack component list and optimization conditions.
PreviewSecop SC18CLX.2 Compressor Technical Data and Specifications
Detailed technical specifications, dimensions, electrical data, and performance tables for the Secop SC18CLX.2 compressor. Includes information on operating limits, configurations, and mounting accessories.
PreviewSecop SC15CL Compressor Technical Data Sheet
Comprehensive technical data, specifications, dimensions, electrical information, and performance tables for the Secop SC15CL compressor (220-240V, 50Hz, CSIR) with configurations for R404A and R452A refrigerants.
PreviewSECOP FRK6G Compressor Technical Data Sheet
Detailed technical specifications, dimensions, electrical data, and performance tables for the SECOP FRK6G compressor, designed for R134a refrigerant and operating on 220-240V/50Hz and 208-230V/60Hz power supplies.
PreviewSecop SC10DL Compressor: Technical Data, Specifications, and Performance
Comprehensive technical datasheet for the Secop SC10DL compressor (Model 104L2525), detailing its specifications, dimensions, electrical data, performance tables, and operating limits for refrigerants like R404A, R507, and R407C. Includes single pack component list and service information for R290.