Aquastrong Instruction Manual

Submersible Utility Pump

Models: ESU050PM, ESU100PM

1. Introduction

These operating instructions are provided to help users operate this pump safely and effectively. It is important to read these instructions carefully before use and pay close attention to all safety warnings.

This appliance may be used by children aged 8 years and above, and by persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, provided they are supervised or instructed on the safe use of the appliance and understand the associated hazards. Children should not play with the appliance, and cleaning and user maintenance should not be performed by children without supervision.

These instructions are intended for individuals with basic technical knowledge of pump operation. Inexperienced users are advised to seek guidance from an experienced person before operating the pump.

Keep all supplied documents with the pump for future reference and retain proof of purchase for warranty claims. The pump must not be sold or lent without these operating instructions and other accompanying documents. The pump must be connected to a residual current device (RCD) with a rated residual operating current not exceeding 30 mA.

2. Caution

The manufacturer is not liable for any damage resulting from the non-observance of operating or safety instructions.

Danger! Risk of personal injury or damage to the environment.

! Risk of electric shock!

Note: Additional information.

Caution! Risk of material damage.

Meaning of crossed-out wheeled dustbin: Do not dispose of electrical appliances as unsorted municipal waste; use separate collection facilities. Contact your local government for information on available collection systems. Improper disposal can lead to hazardous substances leaking into groundwater and the food chain, potentially harming health and well-being.

When replacing old appliances, the retailer is legally obligated to take back the old appliance for disposal, free of charge.

Range of Application and Pumping Media

This pump is designed for pumping clear water in domestic applications, such as for containers, sumps, and flooded basements. Its special design allows for pumping down to a very low water level, for circulation to prevent stagnation, and for feeding decorative water features.

Caution! The maximum permissible fluid temperature is 96°F (35°C). Pumping liquids containing abrasives (like sand) will reduce the pump's service life.

3. Safety

Specified Conditions of Use

This pump must not be used for drinking water or foodstuff. Do not pump explosive, flammable, aggressive fluids, or substances harmful to health. This equipment is not suitable for commercial or industrial use. Any other use is considered improper and may cause unforeseeable damage. Alterations to the machine or the use of unapproved parts are prohibited.

General Safety Instructions

Attention: Children should be supervised to ensure they do not play with the appliance. Observe all local regulations for the safe operation of submersible pumps.

The following residual risks exist and cannot be fully eliminated:

Hazard generated by ambient conditions! Do not use the pump in hazardous locations or near flammable liquids and gases!

Danger! Risk of electric shock! If the appliance or supply cord is damaged, it must be repaired by the manufacturer, its service agent, or a qualified person. Leakage of lubricants could pollute the liquid.

Unplug: Before all servicing.

Danger! Risk of electric shock!

4. Prior to Operation

Installation

5. Installation

Hose connections

Note: A larger connecting pipe diameter results in greater water flow.

Connections:

Caution! Do not lift the pump by the cable or discharge hose, as they are not designed to support the pump's weight.

  1. Submerge the pump at an angle to prevent an air cushion from forming, which could hinder priming. Once submerged, it can be set upright.
  2. Lower the pump to the bottom of the fluid container using a strong rope attached to the cable eye.
  3. The pump can also be operated while suspended by a rope.

6. Care and Maintenance

Danger! Prior to all servicing: Switch Off. Unplug.

Service and repair work beyond what is described here must be performed by qualified specialists.

Periodic maintenance

Regular maintenance ensures the pump's optimal performance. This is also important if the pump is used under demanding conditions or remains idle for extended periods (e.g., in well drains).

PS: For permanent installations, ensure the installation site is clear of sludge and pebbles before installing the pump. Placing the pump on a solid base is recommended.

Yearly service

  1. Check the pump casing and cables for damage.
  2. Rinse the pump with clean water. Remove stubborn dirt, such as algae deposits, using brushes and dishwashing liquid.
  3. To flush the pump's interior, place it in a container of clean water and briefly switch it ON.

Pump storage

Caution! Frost can damage the pump and accessories as they always contain water!

Before maintenance

WARNING! Electric shock! Risk of injury due to electric shock. Disconnect the product from the mains before performing maintenance.

7. Trouble Shooting

MalfunctionCause InvestigationTreatment Measures
The pump does not deliver water.
  • The water inlet filter is clogged.
  • The impeller is blocked or damaged.
  • The installation head is higher than the pump lift.
  • Air cannot escape as the pressure line is closed (e.g., kinked pressure hose).
  • Air locks in the suction base.
  • Water height falls below the minimum water level.
  • Clear the blockage.
  • Remove obstacles or replace the impeller.
  • Install a more powerful pump.
  • Open the pressure line.
  • Wait for approx. 60 seconds until the pump deaerates automatically via the vent valve. If necessary, switch it off and start it again.
  • Submerge the pump deeper into the water.
The water outlet valve does not start when it is closed and reopened.Check whether the check valve is blocked.Reinstall the check valve to ensure there is no blockage.
The flow becomes smaller.
  • Partial blockage of the water inlet filter.
  • The impeller is partially blocked.
  • Remove obstacles.
In the state of the water level when the switch is turned on, the pump will stop after working for a period.Check whether the fluid density or temperature is too high, causing the motor to overheat. The thermal overload protection device may be activated.Check fluid density and temperature. Allow the pump to cool down.
The motor does not start and there is no noise.
  • No power.
  • Check whether the plug connection is good.
  • Check the power supply and the plug.
Pump runs, but the output suddenly decreases.Suction base is clogged.Clean the suction base.

If in doubt, please contact the Aquastrong Service Team by email.

8. Technical Data

Technical parameters

ModelESU050PMESU100PM
Power1/2 HP1 HP
Max Flow3159 GPH4500 GPH
Max Head26 ft30 ft
Degree of Motor ProtectionClass FClass F
Protection ClassIPX8IPX8
Ambient Temperature23°F - 104°F (-5°C - 40°C)23°F - 104°F (-5°C - 40°C)
Fluid Temperature32°F - 95°F (0°C - 35°C)32°F - 95°F (0°C - 35°C)
Max. Dia. of Particle0.19" (5 mm)0.19" (5 mm)
Min. Suction Water Level0.6" (15 mm)0.6" (15 mm)
Min. Residual Water Level0.19" (5 mm)0.19" (5 mm)

ESU050PM:

HorsepowerVoltageAMPDischarge NPT (In)Power cord length(ft)GPH of Water @ Total Ft. of HeadMax. Head Ft
5ft10ft20ft25ft
1/2 HP115V31-1/2 in1031592547110729926ft

ESU100PM:

HorsepowerVoltageAMPDischarge NPT (In)Power cord length(ft)GPH of Water @ Total Ft. of HeadMax. Head Ft
5ft10ft20ft25ft
1 HP115V31-1/2 in1045003807194094830ft

9. Repairs

Danger! Repairs to electric tools must only be carried out by a qualified electrician! Electric tools needing repair can be sent to an authorized service center in your country. Please include a description of the fault with the electric tool.

Environmental Protection

The pump's packaging is 100% recyclable. Worn-out power tools and accessories contain valuable raw and plastic materials that can be recycled.

This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Attention! Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

Meaning of crossed-out wheeled dustbin: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available.

Models: ESU050PM, ESU100PM, ESU050PM Utility Pump, ESU050PM, Utility Pump, Pump

PDF preview unavailable. Download the PDF instead.

ESU100PM manual ?v=1730180275 Adobe PDF library 16.07 Adobe Illustrator(R) 24.0

Related Documents

PreviewAquastrong PGA150SA Shallow Well Jet Pump Instruction Manual
Comprehensive instruction manual for the Aquastrong PGA150SA shallow well jet pump with pressure tank, detailing applications, safety, installation, start-up, maintenance, troubleshooting, and technical specifications.
PreviewAquastrong Centrifugal Pump User Manual
User manual for Aquastrong Centrifugal Pumps, including models SPRK150 and SPRK200. Provides information on intended use, safety, installation, operation, maintenance, and troubleshooting.
PreviewAquastrong SEP100CA Sewage Pump Instruction Manual
Instruction manual for the Aquastrong SEP100CA submersible sewage grinder pump, covering applications, operation, safety, installation, maintenance, and troubleshooting.
PreviewAquastrong Condensate Tank Pump User Manual - Installation & Troubleshooting
Comprehensive user manual for Aquastrong Condensate Tank Pumps (CDS125S-LV, CDS125STU, CDS320, CDS320TU, CDS325, CDS325TU). Includes important notes, technical specifications, installation guides, and troubleshooting tips.
PreviewAQUASTRONG SMART45 Permanent Magnet Pump Installation and Operation Manual
Comprehensive guide for the AQUASTRONG SMART45 Permanent Magnet Pump, covering installation, operation, troubleshooting, and warranty information. Learn how to set up and maintain your pump for optimal performance.
PreviewAquastrong Sand Filter Pump Limited Warranty and Operation Manual
This document provides the limited warranty, safety instructions, product specifications, assembly breakdown, operating instructions, maintenance tips, and troubleshooting guide for Aquastrong Sand Filter Pumps, including models SFPV120T, SFPV120, SFPV121T, SFPV122T, SFPV140T, and SFPV160T.
PreviewAquastrong Electric Pumps Product Catalog - GoodsDirect2U
Explore the comprehensive Aquastrong Electric Pumps product catalog from GoodsDirect2U. Discover a wide range of water pumps, including jet, submersible, solar, and sewerage pumps, along with essential accessories like pressure switches and tanks. Find specifications, applications, and solutions for your water transfer needs.
PreviewAquastrong Dual Speed Pool Pump: User Manual, Installation, and Maintenance Guide
Comprehensive user manual for Aquastrong Dual Speed Pool Pumps (PSP150AD, PSP200AD), covering installation, operation, maintenance, troubleshooting, and technical specifications. Includes safety instructions and technical data.