30620-EN Ver3.0

ebp2692

TCSCTN011M11F-Datasheet

TCSCTN011M11F | Telemecanique Sensors Tee Socket Adapter | RS

PDF preview unavailable. Download the PDF instead.

0900766b814afc51
Presentation,

Ositrack® RFID

0

description

Radio frequency identification

13.56 MHz

Operating principle
RFID (Radio Frequency IDentification) is a term generally used for radio frequency identification systems. These frequencies range between 50 kHz and 2.5 GHz. The most widely used is 13.56 MHz.
The Ositrack® RFID identification system enables object traceability, identification (tracking) functions to be performed and access control. The information is stored in an accessible memory using a simple radio frequency link. This memory is in the form of an electronic tag, which contains an antenna and an integrated circuit. The tag contains the information associated with the object to which it is fixed. When a tag passes through the field generated by the reader/station, it detects the signal and exchanges the data (read or write) between its memory and the reader/station. The applications are numerous: b Logistics: dispatch, receipt, transit, etc. b Tracking and sorting of baggage b Automatic tolls b Access control, etc. The Ositrack® RFID system is also suited to difficult environments (humidity, temperature, mechanical shock, vibration, dust, etc.).
Ositrack® RFID
Ositrack® is open to the majority of ISO 18000-3, ISO 15693 and ISO 14443 electronic tags. Ositrack® integrates Modbus RTU, Uni-Telway and Modbus TCP/IP protocols.
The Ositrack® RFID offer comprises: b 2 models of 13.56 MHz compact stations (read/write) b 6 models of 13.56 MHz electronic tags b 1 portable RFID diagnostics terminal b 2 models of network connection boxes b connection and mounting accessories.
Setting-up Ositrack® compact stations are simple to set-up: v Integrated RFID and network functions v No programming v Automatic detection of the RFID electronic tags (read or write) v Automatic setting of the communication parameters (speed, format, parity, protocol, etc.) v Configuration of the network address (1 to 15) using badge included with the station v Read/write compatibility with the majority of 13.56 MHz tags on the market v Low sensitivity to metal environments.
Installation The Ositrack® stations are compact and robust. They can easily be integrated in flexible manufacturing production lines:
- quick connection using M12 connector - clip-on mounting. Ositrack® compact stations can be connected on Ethernet, Modbus and Uni-Telway networks and bus via a connection box.
Description
Ositrack® 13.56 MHz compact stations (1) Stations XGC S enable the reading and writing of 13.56 MHz RFID tags that comply to standards ISO 15693 and ISO 14443 A and B. 2 models of Ositrack® compact stations are available: b Format C compact station: Station XGC S490pppp: v Dimensions (mm): 40 x 40 x 15 v Nominal sensing distance: 18 to 70 mm depending on associated tag b Format D compact station: Station XGC S890pppp: v Dimensions (mm): 80 x 80 x 26 v Nominal sensing distance: 20 to 100 mm depending on associated tag.
(1) For station and tag selection according to passing speeds, see page 30620-EN_Ver3.0/14.

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5
2

References: pages 30620-EN_Ver3.0/6 to 30620-EN_Ver3.0/9

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
30620-EN_Ver2.0.indd

Description (continued)

Ositrack® RFID

0

Radio frequency identification

13.56 MHz

1 2 3

5

4

3

IN

5

OUT

2

1

4

1 2 3

Description (continued)
Ositrack® RFID electronic tags (1) b Electronic tags XGH B offer the following advantages: v fast access to the data, v wide range of memory capacities, v access security to the contents, v operation without battery, v positioning flexibility, v and protection suited to the environmental conditions. The nominal transmission distance is 18 to 100 mm depending on the model of the tag and associated compact station.
Connection boxes
Two types of quick connection boxes are available: - an Ositrack® Ethernet box XGS Z33ETH for Ethernet network - an Ositrack® tap-off box TCS AMT31FP for Modbus and Uni-Telway
communication bus. b Ethernet box XGS Z33ETH The Ositrack® Ethernet box XGS Z33ETH enables connection of stations XGC S to the Ethernet network (Modbus TCP/IP protocol). It enables, from a PLC or PC, access to the functions of stations XGC S: v reading/writing of tags, v control and checking, v monitoring, v diagnostics. The Ethernet box XGS Z33ETH is fitted with M12 connectors. It is used to connect the supply, the Ethernet network and 1 to 3 stations XGC S. It comprises a sealed metal enclosure fitted with: 1 Ethernet network signalling LEDs 2 One Ethernet M12 type, D coding, socket 3 One green LED indicator: power on 4 One power supply M12 type 4-pin male socket 5 3 x M12 type female, A coding, sockets for connecting 1 to 3 stations XGC S.
b Tap-off box TCS AMT31FP Tap-off box TCS AMT31FP enables stations XGC S to be connected to Modbus or Uni-Telway communication bus. The tap-off box TCS AMT31FP is fitted with M12 connectors. It is used to connect the supply, the communication bus (Modbus) and 1 to 3 stations XGC S. It comprises a sealed metal enclosure fitted with: 1 One green LED indicator: power on 2 One network output M12 type 5-pin female, A coding, socket 3 One network input M12 type 5-pin male, A coding, socket 4 One power supply M12 type 4-pin male, A coding, socket 5 3 x M12 type female, A coding, sockets for connecting 1 to 3 compact stations
XGC S.
Portable 13.56 MHz RFID diagnostics terminal
The portable terminal XGS TP401 is designed for use in industrial applications. Its hardened structure combined with its numerous functions make it suitable for applications in arduous environments. It operates on Microsoft® Windows CE.NET Professional® version 4.2. The 13.56 MHz RFID function and Ositrack® software installed on the portable terminal enable maintenance operations to be performed on the electronic tags and compact stations. Transfer of data to a PC is made via an RS 232 communication port. The portable terminal XGS TP401 comprises a: 1 Colour touchscreen 2 Keypad (45 keys) 3 RS 232 port The following accessories are included with the terminal:
- a PC connecting cable, - Ositrack® software (installed), - a battery, - a universal battery charger, - 3 styluses, - a protective cover,
- a user guide.
(1) For station and tag selection according to passing speeds, see page 30620-EN_Ver3.0/14.

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5
30620-EN_Ver2.0.indd

References: pages 30620-EN_Ver3.0/6 to 30620-EN_Ver3.0/9

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
3

Characteristics

Ositrack® RFID

0

Radio frequency identification

13.56 MHz

Characteristics of Ositrack® compact stations

Station type

XGC S4901201

XGC S8901201

Certifications Conformity to standards

UL, FCC part 15c e, EN 301489-1, EN 301489-3, ETS 300330-1 and ETS 300330-2

Ambient air temperature

For operation

°C

- 25...+ 55

For storage

°C

- 40...+ 85

Degree of protection

Conforming to IEC 60529

IP 65

Vibration resistance Shock resistance

Conforming to EN 60068.2.27 Conforming to EN 60068.2.6

2 mm from 5 to 29.5 Hz / 7 gn from 29.5 to 150 Hz 30 g/11 ms

Conforming to EN 50102

Degree IK 02

Resistance to interference

Conforming to IEC 61000

Resistance to electrostatic discharge, radiated electromagnetic fields, fast transients, electrical surges, conducted and induced interference and network frequency magnetic fields.

Dimensions, W x H x D

mm C format: 40 x 40 x 15

D format: 80 x 80 x 26

RFID frequency

MHz 13.56

Type of associated tag

ISO 15693 and ISO 14443 standard tags. Automatic detection of the type of tag

Nominal sensing distance

Depending on associated tag mm

Nominal supply voltage

V

Supply voltage limits (including ripple)

V

18 to 70

20 to 100

c 24 PELV (Protective Extra Low Voltage)

c 19.2...29

Consumption

mA < 60

Serial links

Type

RS 485

Protocol Speed

Modbus RTU or Uni-Telway Bauds 9600...115 200 (automatic detection)

Display Connections

1 dual colour LED for the communication network: Modbus/Uni-Telway 1 dual colour LED for the RFID communication (Presence of tag / Station/tag dialogue)
M12, 5-pin male, shielded connector. Only for connection to the communication network and the supply.

Tightening torque

Screws

Nm < 1

< 3

Characteristics of electronic tags
Tag type

Ambient air temperature
Degree of protection Standard supported Vibration resistance Shock resistance
Dimensions Housing material Fixing method

For operation

°C

For storage

°C

Conforming to EN 60068.2.27 Conforming to EN 60068.2.6 Conforming to EN 50102
mm

XGH B444345

XGH B445345

XGH B90E340

XGH B320345

- 25...+ 70

- 25...+ 50 - 25...+ 70

- 40...+ 85

- 40...+ 55 - 40...+ 85

IP 68

IP 65

ISO 14443

ISO 15693

2 mm from 5 to 29.5 Hz / 7 gn from 29.5 to 150 Hz

30 g/11 ms

Degree IK 02

40 x 40 x 15 40 x 40 x 15 54 x 85.5 x 1 Ø 30 x 3

PBT

PBT

PVC

PC

Screw or clip Screw or clip ­

Screw

XGH B221346

XGH B211345

IP 68

26 x 26 x 13 M18 x 1 x 12

PBT

PBT

Screw or clip Screw in

Memory capacity Type of memory Type of operation Type of associated station Nominal sensing distance (Read/Write) Number of read cycles Number of write cycles
Read time
Write time
Data retention time Mounting on metal support

With station XGC S49 With station XGC S89
Guaranteed minimum At 30 °C

bytes 3 408

13 632

256

112

256

EEPROM

Read/Write XGC Sppppppp

mm 33

30

70

48

40

18

mm 48

40

100

65

55

20

Unlimited

100 000 per data bit throughout the temperature range

2.5 million (typical value)

ms

9.25 +

16.25 +

12 + 0.825 x n (1)

0.375 x n (1) 0.375 x n (1)

ms

13 +

20 +

20 +

12 +

20 +

19 +

0.8 x n (2) 0.8 x n (2) 11.8 x n (2) 5.6 x n (2) 11.8 x n (2) 4.1 x n (2)

10 years

Yes (2)

No

Yes (2)

No

(1) n = number of 16-bit words.

(2) Installation precautions: see pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15.

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
4

References: pages 30620-EN_Ver3.0/6 to 30620-EN_Ver3.0/9

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
30620-EN_Ver2.0.indd

Characteristics (continued) Ositrack® RFID 0
Radio frequency identification 13.56 MHz

Characteristics of connection boxes
Connection box type Certifications
Conformity to standards

Tap-off box TCS AMT31FP UL
e

Ethernet box XGS Z33ETH

Ambient air temperature

For operation For storage

°C

- 25...+ 55

°C

- 40...+ 85

0...+ 50 - 40...+ 66

Relative humidity

RH

30...95% without condensation

Degree of protection Supply voltage

IP 65

V

c 24 PELV (limits 19.2 V...29 V). M12, 4-pin male, A coding, connector

Consumption (connection box only)

W

­

< 1

Station connection

M12 5-pin female, A coding, connector

Electromagnetic interference Conforming to IEC 61000 Conforming to EN 55022

Level 3 Class B

LED display

Power on (green)

- Ethernet network activity (RUN, green) - Collision detection (COL, red) - Diagnostics (STS, yellow) - Fault (Err, red) - Power on (green)

Transparent Ready Services Class

­

Basic Web server

­

Basic Ethernet TCP/IP

­

communication service

A10 Available later Modbus messaging (read/write of words)

Ethernet connection

Physical interface

­

Transfer rate

­

Medium

­

10 BASE-T/100BASE-TX
10/100 Mbps
Ethernet cable with M12 connection, reference TCS ECL1M1pS2 (Telemecanique ConneXium range)

Characteristics of portable 13.56 MHz RFID diagnostics terminal

Conformity to standards

e, FCC class A, Part 15225

Ambient air temperature

For operation

°C

0 ... + 50

For storage

°C

- 25... + 55

Relative humidity

RH

5...95% without condensation

Degree of protection

IP 65

Supply voltage Operating time

7.2 V NiMH type rechargeable battery (included with terminal) External: c 11-18 V 4 hours continuous operation (tag dialogue)

Operating system

Microsoft Windows CE.NET Professional® version 4.2

Processor

Intel technology Xscale PXA255 CPU, 400 MHz

Memory

RAM Storage

SDRAM 64 Mb
Internal compact Flash: 64 Mb standard (16 Mb reserved for operating system), expandable to 128 Mb + Slot for compact Flash card

Display

Screen Resolution

Colour touchscreen: 72 mm x 54 mm, QVGA TFT 320 x 240 pixels

Keypad

45 booted keys

Signalling

5 LEDs + 1 charging LED

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
30620-EN_Ver2.0.indd

References: pages 30620-EN_Ver3.0/6 to 30620-EN_Ver3.0/9

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
5

105909

References

Ositrack® RFID 0
Radio frequency identification 13.56 MHz

Compact stations, 13.56 MHz

Description
Compact station C format (1) M12 male connector on flying lead

Protocols

Dimensions

mm

Modbus RTU 40 x 40 x 15

and Uni-Telway

Reference XGC S4901201

Weight kg
0.057

Compact station D format (1) M12 male connector on flying lead

Modbus RTU 80 x 80 x 26 and Uni-Telway

XGC S8901201

0.257

XGC S4901201

Electronic tags

Tag type

Nominal sensing dist. Dimensions according to station mm XGC S49p XGC S89p

C format 3 408 bytes

33 mm

48 mm

40 x 40 x 15

Sold in Unit reference lots of

­

XGH B444345

Weight kg
0.031

C format

30 mm

13 632 bytes

40 mm

40 x 40 x 15 ­

XGH B445345

0.031

ISO badge (2) 70 mm 256 bytes

100 mm 54 x 85.5 x 1 10

XGH B90E340

0.005

XGH B44p345

XGH B90E340

Disc

48 mm 65 mm Ø 30 x 3

5

112 bytes

E format 256 bytes

40 mm 55 mm 26 x 26 x 13 1

XGH B320345 XGH B221346

0.005 0.025

XGH B221346

XGH B211345

XGH B320345

Cylindrical 256 bytes

18 mm

20 mm

M18 x 1 x 12 5

XGH B211345

0.020

(1) Configuration badge XGS ZCNF01 included with station - installation guide to be ordered separately (reference DIA4ED3051001).
(2) Customised versions on request.

105910 105914

105911 105912
105913

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
6

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
30620-EN_Ver2.0.indd

105915

105918 PF540455

References (continued)
TCS AMT31FP

XGS TP401

XGS TP41CH

XGS TP41BA

XGS ZCNF01

Ositrack® RFID 0
Radio frequency identification 13.56 MHz

Connection boxes

Description

For use with

Ethernet box

Compact stations

3-channel

XGC S49p and

Integrated Ethernet port XGC S89p

(10/100 Mbps)

Modbus TCP/IP protocol

Class A10

Supply voltage c 24 V

Reference XGS Z33ETH

Weight kg
1.060

Tap-off box

Compact stations

3-channel

XGC S49p and

Modbus and Uni-Telway XGC S89p

c 24 V

TCS AMT31FP

1.060

Ositrack® terminal and accessories

Description

Application

Reference

Portable 13.56 MHz RFID diagnostics terminal (1)

Read/write operations on electronic tags and diagnostics on compact stations Operating system: Microsoft Windows CE.NET Professional® version 4.2

XGS TP401

Battery pack charger Portable terminal

XGS TP41CH

Battery, 7.2 V NiMH Portable terminal

XGS TP41BA

Compact Flash memory expansion

Portable terminal Capacity = 128 Mb

XBT ZGM128

Weight kg
0.943
0.675 0.168 0.050

Configuration badge (replacement)

Description

Application

Badge

Configuration of station addresses

Reference XGS ZCNF01

Weight kg
0.005

Ositrack® documentation
Description
Ositrack® compact stations guide

Reference DIA4ED3051001

Weight kg
0.130

(1) Ositrack® software (installed), universal battery charger, PC connecting cable, 3 styluses, protective cover, battery and user guide included with terminal.

105920 105921

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
30620-EN_Ver2.0.indd

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
7

References (continued)

Ositrack® RFID

0

Radio frequency identification

13.56 MHz

105925

105927

105924

TCS MCN1FQM2 TCS MCN1F9M2P TCS ECL1M3Mppp TCS ESU051F0 TCS EAAF11F13F00 TCS CTN011M11F

Connection accessories

Description

Application

Length m

Modbus network connection accessories

Modbus shielded connecting cable, black, IP 67 M12 connectors, male/female, A coding (1)

RS485 connection between 1 a compact station and a 2 tap-off box TCS AMT31FP or between 2 tap-off boxes 5
10

Modbus shielded pre-wired M12 connector, IP 67, female/bare wires, A coding (1)

Connection between tap-off 2

box TCS AMT31FP and 5

Modbus/Uni-Telway (TSX SCA50)

network

10

Reference
TCS MCN1M1F1 TCS MCN1M1F2 TCS MCN1M1F5 TCS MCN1M1F10
TCS MCN1F2 TCS MCN1F5 TCS MCN1F10

Weight kg
0.080 0.115 0.270 0.520
0.115 0.270 0.520

Modbus shielded connecting cable, black, M12/SUB-D15, A coding

Connection between tap-off 2 box TCS AMT31FP and Modbus/Uni-Telway network (TSX SCA62)

TCS MCN1FQM2

0.270

Modbus shielded connecting cable, black, M12/Mini-DIN 8-way, A coding

Modbus connection

2

between tap-off box

TCS AMT31FP and a PLC

(Twido...)

Modbus SL serial link Modbus SL serial link

100

cable (Shielded dual

200

twisted pair RS485 main cables)

500

TCS MCN1F9M2P

0.350

TSX CSA100 TSX CSA200 TSX CSA500

5.680 10.920 30.000

Ethernet connection accessories

Ethernet connecting Connection between the 1

cable, green, M12

Ethernet box XGS Z33ETH 2

ConneXium (2) 2 M12 4-pin connectors,

and an M12 Ethernet TCS ESU051F0

switch

5

D coding

10

Ethernet shielded

Connection between the 1

connecting cable,

Ethernet box and the

3

ConneXium (2), M12 male

Ethernet network

5

D coding/RJ45, 4-pin

10

40

TCS ECL1M1M1S2 TCS ECL1M1M2S2 TCS ECL1M1M5S2 TCS ECL1M1M10S2

0.080 0.115 0.270 0.520

TCS ECL1M3M1S2 TCS ECL1M3M3S2 TCS ECL1M3M5S2 TCS ECL1M3M10S2 TCS ECL1M3M40S2

0.075 0.110 0.265 0.515 2.000

M12 Ethernet switch ­

­

IP 67, ConneXium (2)

Adaptor

Ethernet connection

­

M12 female/RJ45

TCS ESU051F0

0.210

TCS EAAF11F13F00

­

Other connection accessories

Pre-wired M12 4-pin c 24 V supply to

2

female connector,

connection boxes

5

A coding (1)

XGS Z33ETH and TCS AMT31FP

10

Shielded M12 5-pin ­

­

female, A coding,

connector

Shielded M12 5-pin ­

­

male, A coding,

connector

Network "T" connector, RS485 network

­

M12, 1 male/2 female

5-pin, A coding

Supply connector,

­

­

screw terminals,

M12 straight, A coding

Protective cap (Sold in lots of 10)

M12 female connector

­

Network terminator, ­

­

M12 male, 120 

XGS Z08L2 XGS Z08L5 XGS Z08L10
FTX CN12F5

0.115 0.270 0.520
0.050

FTX CN12M5

0.050

TCS CTN011M11F

0.035

XZC C12FDM40B

0.020

FTX CM12B FTX CNTL12

0.100 0.010

(1) Holder for identification legend included with product. (2) Other ConneXium connection accessories: please refer to www.telemecanique.com.

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
8

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
30620-EN_Ver2.0.indd

535803

535625

540456

105922

References (continued)
XGS Z3P XGS Z05 ABL 8MEM24003

Ositrack® RFID 0
Radio frequency identification 13.56 MHz

Mounting accessories

Description

For use with

"Clip-on" 90° mounting bracket

C format station: XGC S4901201 C format tags: XGH B44p345
Tags XGH B221346

"Clip-on" mounting plate

C format station: XGC S4901201 C format tags: XGH B44p345
Tags XGH B221346

Mounting plate

Connection boxes TCS AMT31FP and XGS Z33ETH

Reference XSZ BC90
XSZ BE90 XSZ BC00
XSZ BE00 XGS Z3P

Weight kg
0.060
0.060 0.025
0.025 0.195

Complementary accessories
Description

Sold in lots of

Key for screwing in/unscrewing Ø 18 mm

5

cylindrical tag

Identification legend for 23 x 4 mm connecting 200 cables

Power supplies

Description

Output voltage c V

Regulated power

24

supply

100/240 V

Nominal power W 7
30

Nominal current A 3
1.2

Unit reference XGS Z05

Weight
kg 0.011

XGS Z08MKW

0.056

Reference

Weight

ABL8 MEM24003

kg 0.180

ABL8 MEM24012 0.520

806603

106410

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
30620-EN_Ver2.0.indd

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
9

Dimensions

Ositrack® RFID 0
Radio frequency identification 13.56 MHz

Compact stations

XGC S4901201

15

40

9,8

33

4XØ4,5

XGC S8901201 26 16

80
65 4XØ5,5

14 40

80

() (1)

(1) For CHC type screws. (2) Shielded cable (length: 20 cm).

Read/write electronic tags

Square format tags XGH B44p345

15

40

9,8

33

4XØ4,5 (1)

40

(1) For CHC type screws. Rectangular format tags

XGH B90E340

1

85,5

14

()
(1) (3) M12 5-pin male, A coding, shielded connector.

XGH B221346

13

26

8,8

33 4XØ3,5 (1)

Cylindrical format tags XGH B320345
3 Ø3

XGH B211345 12

M18X1

Ø30 26

54

Connection boxes (1)
TCS AMT31FP

XGS Z33ETH

=

80

50

IN

OUT

=

51

=

115

=

130

(1) Allow a 110 mm clearance zone for connecting the cables. Mounting plate XGS Z3P

=

140

=

60

2xØ4,3 2xØ5,4

2,5

=

115

=

10

= 50

=

74

51

=

115

=

130

30620-EN_Ver2.0.indd

=

50

=

80

Dimensions (continued)

Ositrack® RFID

0

Radio frequency identification

13.56 MHz

Ositrack® RFID portable diagnostics terminal
XGS TP401

120,6

333,5 250

39,6

96

62

Mounting brackets
XSZ BC90

Mounting plates
XSZ BC00

16

(1)

M5

16

(1)

6 17
10 30 42 27,4 42 17 6 30 10 27,4

36,9

M5

44,4

(1) Four M4 x 14 screws (included).

XSZ BE90

30,8

23,9

(1)

4,5

77,2

44,3

12

(1) Four M4 x 14 screws (included).

XSZ BE00

11,9

M3

10

10

M3

29,4

(1) Two M3 x 12 screws (included).

5,5

(1)

48,5

(1) Two M3 x 12 screws (included).

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
30620-EN_Ver2.0.indd

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5

References: pages 30620-EN_Ver3.0/6 to 30620-EN_Ver3.0/9

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
11

Connections

Ositrack® RFID 0
Radio frequency identification 13.56 MHz

Modbus connections Stations XGC Sp901201

4

3

(1)

5

1

2

(2)

(1) Shielding per pair. (2) General cable shielding. Tap-off box TCS AMT31FP Socket to station cabling

Pin n°

Signal

1

2 1­

5

2 Red

Drain (Modbus-SHLD) c + 24 V

4

3 3 Black 0 V/Modbus-GND

4 White D0

5 Blue D1

Connector Shielding casing

Pin n° 1 2 3 4 5 Connector casing

Station - Modbus signal Drain (Modbus-SHLD) c + 24 V 0 V/Modbus-GND D0 D1 Shielding

Socket to power supply cabling

Pin n° Signal

2

11

c + 24 V

2

3

43

4

c + 24 V c 0 V c 0 V

Socket to another connection box cabling

Pin n° Signal

1

21

5

2

Drain (Modbus-SHLD)
­

4

33

0 V/Modbus-GND

4

D0

5

D1

Connector Shielding casing

Socket to industrial PLC cabling

Pin n° Signal

2

11

5

2

Drain (Modbus-SHLD)
­

3

43

0 V/Modbus-GND

4

D0

5

D1

Connector Shielding casing

Cable connections TCS MCN1Fp

1

2

5

4

3

Pin n° 1 ­
2 Red 3 Black 4 White 5 Blue Connector casing

Signal Drain (Modbus-SHLD) c + 24 V 0 V/Modbus-GND D0 D1 Shielding

XGS Z08L

1

2

4

3

Pin n° 1 Brown
2 White 3 Blue 4 Black

Signal c + 24 V
c + 24 V c 0 V c 0 V

Mounting example for Modbus network Premium
IN L
l1

L1

OUT

IN

24 V

l2

l3

OUT
24 V l4

Maximum length of bus The maximum length of the bus (L + L1 + l4) depends on the speed of the network: - 9600 bauds: 1000 m, - 19 200 bauds: 500 m.
Maximum length of tap-offs: l1, l2 and l3: 10 m.

Example of connection to a Telemecanique PLC Direct connection
PLC

Connection via a TSX SCA62 PLC

IN TCS MCN1F9M2P
TCS MCN1M1Fp

OUT XGS Z08Lp c 24 V

TSX CSAp00

TSX CSA62

IN TCS MCN1FQM2

TCS MCN1M1Fp

OUT XGS Z08Lp c 24 V

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
12

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5

References: pages 30620-EN_Ver3.0/6 to 30620-EN_Ver3.0/9

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
30620-EN_Ver2.0.indd

Connections (continued)

Ositrack® RFID

0

Radio frequency identification

13.56 MHz

Ethernet connection

Ethernet box XGS Z33ETH

Socket to station cabling

Pin n°

Signal

1

2 1­

5

2 Red

Drain (Modbus-SHLD) c + 24 V

4

3 3 Black 0 V/Modbus-GND

4 White D0

5 Blue D1

Connector Shielding casing

Ethernet socket connection 1

4

52

3

Socket to power supply cabling

Pin n° Signal

2

11

c + 24 V

2

3

43

4

c + 24 V c 0 V c 0 V

Cable XGS Z08L connections

Pin n°

Signal

1

2 1 Brown c + 24 V

2 White c + 24 V

4

3 3 Blue

c 0 V

4 Black

c 0 V

Cable TCS ECL1M3MppS2

M12 Signal 1 TD + 3 TD ­ 2 RD + 4 RD ­

Signal RJ45 TD + 1 TD ­ 2 RD + 3 RD ­ 6

Connection example on Ethernet Modbus TCP/IP network IP 67

IP 20 PLC

TCS ECL1M1MpS2

TCS ESU051F0 TCS ECL1M1MpS2 TCS ECL1M3MpS2

TCS EAAF11F13F00

TCS ECL1M1MpS2

ABL 7

c 24 V

c 24 V

c 24 V

XGS Z08Lp

XGC S49/89

XGS Z33ETH

XGS Z33ETH

XGS Z33ETH TCS MCN1M1Fp

XGC S49/89

XGC S49/89

ConneXium switch

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
30620-EN_Ver2.0.indd

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5

References: pages 30620-EN_Ver3.0/6 to 30620-EN_Ver3.0/9

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Curves, installation: pages 30620-EN_Ver3.0/14 and 30620-EN_Ver3.0/15
13

Curves

Ositrack® RFID 0
Radio frequency identification 13.56 MHz

(1)

Detection zones of compact stations Sn

Angular positioning between station and tag

K

1



0,85

y 60°

0

0

60 90 (°)

(1) Recommended crossing zone: between 0.4 and 0.8 Sn.

K = correction coefficient to be applied to the nominal sensing distance. Read distance = nominal sensing distance x K.

Station and tag selection according to passing speeds

Read time with station XGC S49ppppp

Write time with station XGC S49ppppp

Passing speed (m/min)

Passing speed (m/min)

1 XGH B444345

300

250

2 XGH B445345

3 XGH B211345

250

4 XGH B320345

200

5 XGH B90E340

200

6 XGH B221346

150

150

41

100 2

1

100 2

50

50

3

0

3-4-5-6

0 20 40 60 80 100 120

Number of words

0 5-6 0 20 40 60 80 100 120
Number of words

Read time with station XGC S89ppppp Passing speed (m/min) 600

500

400

300

200 2

1

100

0

3-4-5-6

0 20 40 60 80 100 120

Number of words

Write time with station XGC S89pppp Passing speed (m/min) 450

400

350

300

4 250
1 200

150

2

100 3
50
0 5-6 0 20 40 60 80 100 120
Number of words

1 XGH B444345 2 XGH B445345 3 XGH B211345 4 XGH B320345 5 XGH B90E340 6 XGH B221346

Application example

Read time with station XGC S49ppppp

Read time with station XGC S89ppppp

On an assembly line, the object passing speed is 100 m/min. The application requires that 60 words be read.

Passing speed (m/min)
300

Passing speed (m/min)
600

250

500

200

400

150 100 2
50 0 0 20

1

3-4-5-6 40 60

80 100 120
Number of words

300

200 2

1

100

0

3-4-5-6

0 20 40 60 80 100 120

Number of words

Station XGC S49 cannot be used; no Ositrack® tag can be read under these conditions (Speed/Number of words).

Station XGC S89 can be used; only tags XGH B444345 and XGH B445345 meet the requirements (Speed/Number of words).

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
14

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5

References: pages 30620-EN_Ver3.0/6 to 30620-EN_Ver3.0/9

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13
30620-EN_Ver2.0.indd

Installation precautions

Ositrack® RFID

0

Radio frequency identification

13.56 MHz

Minimum mounting distances between system components Distance between stations Minimum distance between 2 identical stations in relation to their positioning and type of tag used (mm)

e1 e2

Tag

C format XGC S4 stations D format XGC S8 stations

e1

e2

e3

e1

e2

e3

XGH B90E340 310

550

120

430

750

280

XGH B221346 200

320

100

280

530

260

XGH B320345 140

360

110

310

540

240

e3

XGH B211345 210

180

60

200

370

170

XGH B444345 90

190

30

310

400

160

XGH B445345 110

170

30

310

380

160

Distance between tags Minimum distance between 2 identical tags in relation to their positioning and type of station used (mm)

e1

Tag

C format XGC S4 stations D format XGC S8 stations

e1

e2

e1

e2

XGH B90E340 35

60

110

140

e2

XGH B221346 50

10

120

50

XGH B320345 70

50

190

60

XGH B211345 40

10

120

20

XGH B444345 20

10

70

40

XGH B445345 10

10

60

10

Minimum permissible mounting distances in a metal structure

Stations XGC S49/S89 and Tags XGH B221346/B444345/B445345

Tags XGH B90E340 and XGH B211345

Tag XGH B320345

No metal parts within 25 mm of the tag. (1)

e

e

e

e

e u 20 mm.

e

e

e u 20 mm.

Tags
XGH B90E340 XGH B221346 XGH B320345 XGH B211345 XGH B444345 XGH B445345

Nominal sensing distance (mm)

XGC S49 70 40 48 18 33 30

XGC S89 100 55 65 20 48 40

e u 15 mm.

Reduced sensing distance with presence of metal (mm)

XGC S49

XGC S89

58

80

30

33

45

56

16

15

28

34

24

28

(1) Tightening torque y 1 N.m.

e

Presentation, description: pages 30620-EN_Ver3.0/2 and 30620-EN_Ver3.0/3
30620-EN_Ver2.0.indd

Characteristics: pages 30620-EN_Ver3.0/4 and 30620-EN_Ver3.0/5

References: pages 30620-EN_Ver3.0/6 to 30620-EN_Ver3.0/9

Dimensions: pages 30620-EN_Ver3.0/10 and 30620-EN_Ver3.0/11

Connections: pages 30620-EN_Ver3.0/12 and 30620-EN_Ver3.0/13
15


Acrobat Distiller 8.1.0 (Windows)