Functional Devices™ RIBU1C | Geary Pacific Supply
RELAYS PILOT RELAYS: 1015 AMPS Enclosed | T Style | Track Mount Prepackaged For Convenience Great Time Saver · LED indicator · 10-15 Amp models · Multi-voltage coil input · Pre-wired · Several different contact ratings · Track mount panel style · True override switch on load side of relay · Time delay models · High/low voltage separation Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). ENCLOSED PILOT RELAYS COIL VOLTAGE MODEL # RIBU1C · RIBH1C · RIBU2C · RIBH2C · RIBL3C · RIBL4C · RIBU1S · RIBH1S · RIBU1SM-250 · RIBH1SM-250 · RIB2401D · RIB2402D · RIBU1SC · RIBH1SC · RIBL1C-DC · RIB2421C · RIBD2421C · RIBU2SC · RIBU2S2 · AC/DC 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 24 24 10-30 10-30 10-30 1 24 24 10-30 10-30 AC 120 208-277 120 208-277 120 208-277 120 208-277 120 208-277 120 208-277 120-277 120-277 120 120 RELAYS 1 1 2 2 3 4 1 1 1 1 1 1 1 1 1 1 1 2 2 CONTACTS SPDT SPDT 2 SPDT 2 SPDT 3 SPST 3 SPST, 1 SPDT SPST SPST SPST SPST DPDT DPDT SPDT SPDT SPDT SPDT SPDT 1 SPST, 1 SPDT 2 SPST OVERRIDE SWITCH 1 1 1+monitor 1+monitor 2 3 2 3 1 2 NOTES 2 SPEC PAGE 4 4 5 5 5 5 6 6 6 6 7 7 7 7 8 8 9 10 10 T STYLE PILOT RELAYS COIL VOLTAGE MODEL # RIBTU1C · RIBTH1C · RIBTU2C · RIBTH2C · RIBU1CW · RIBH1CW · RIBTU1S · RIBTH1S · RIBTU1SC · RIBTH1SC · RIBT2401D · AC/DC 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 24 AC 120 208-277 120 208-277 120 208-277 120 208-277 120 208-277 120 RELAYS 1 1 2 2 1 1 1 1 1 1 1 CONTACTS SPDT SPDT 2 SPDT 2 SPDT SPDT SPDT SPST SPST SPDT SPDT DPDT OVERRIDE SWITCH 1 1 2 3 2 3 NOTES SPEC PAGE 11 11 11 11 12 12 12 12 13 13 13 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 1 = DC Only 2 = Time Delay 3 = SPDT with override requires 2 switches (800) 888-5538 | www.functionaldevices.com 3 RELAYS TRACK MOUNT PILOT RELAYS COIL VOLTAGE MODEL # RIBAN12C · 1 RIBAN24C · 1 RIBM12C · RIBM12S · RIBM24C · RIBM24S · RIBM2401D · RIBM2402D · RIBMU1C · RIBMU1S · RIBMH1C · RIBMH1S · RIBMU2C · RIBMH2C · RIBMU1SM-250 · RIBMH1SM-250 · RIBMU1SC · RIBMH1SC · RIBMN12C · RIBMN12S · RIBMN24C · RIBMN24S · RIBMN24S-J · RIBMN24C-4T · RIBMN24S-4T · RIBMN2401D · RIBMNU1C · RIBMNU1S · RIBMNH1C · RIBMNH1S · RIBMNU1SM-250 · RIBMNH1SM-250 · AC/DC 12 24 12 12 24 24 24 24 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 10-30 12 12 24 24 24 24 24 24 10-30 10-30 10-30 10-30 10-30 10-30 AC 120 208-277 120 120 208-277 208-277 120 208-277 120 208-277 120 208-277 120 120 120 208-277 208-277 120 208-277 RELAYS 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 4 4 1 1 1 1 1 1 1 CONTACTS SPDT SPDT SPDT SPST SPDT SPST DPDT DPDT SPDT SPST SPDT SPST 2 SPDT 2 SPDT SPST SPST SPDT SPDT SPDT SPST SPDT SPST SPST 4 SPDT 4 SPST DPDT SPDT SPST SPDT SPST SPST SPST OVERRIDE SWITCH 1 1 1 1 1+monitor 1+monitor 2 2 2 2 1 1 1 4 1 1 1+monitor 1+monitor NOTES SPEC PAGE 14 14 15 15 15 15 16 16 16 17 16 17 17 17 18 18 18 18 19 19 19 19 20 20 20 21 21 22 21 22 18 18 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 1 = UL Listed : UL508 only ; USA & Canada 2 = SPDT with override requires 2 switches 10 AMP PILOT CONTROL RELAYS RIBU1C Enclosed Relay 10 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBH1C Enclosed Relay 10 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Made in USA Meets "Buy American" of ARRA 2009 RIBU1C-RD RIBH1C-RD · Red housing RIBU1C-N4 RIBH1C-N4 · NEMA 4X housing, UL508 only SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Contact Ratings: Coil Current: Expected Relay Life: 10 million cycles minimum mechanical 10 Amp Resistive @ 277 Vac 33 mA @ 10 Vac 13 mA @ 10 Vdc Operating Temperature: -30 to 140° F 10 Amp Resistive @ 28 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc Humidity Range: 5 to 95% (noncondensing) 480 VA Pilot Duty @ 240-277 Vac 46 mA @ 24 Vac 18 mA @ 24 Vdc Operate Time: 20ms 480 VA Ballast @ 277 Vac 55 mA @ 30 Vac 20 mA @ 30 Vdc Relay Status: LED On = Activated Not rated for Electronic Ballast 28 mA @ 120 Vac (RIBU1C) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple 600 Watt Tungsten @ 120 Vac (N/O) 39 mA @ 208-277 Vac (RIBH1C) Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 4 Functional Devices, Inc. | American Made. American Owned. RELAYS 10 AMP PILOT CONTROL RELAYS RIBU2C Enclosed Relays 10 Amp 2 SPDT with 10-30 Vac/dc/120 Vac Coil RIBH2C Enclosed Relays 10 Amp 2 SPDT with 10-30 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Red 120 Vac Gry/Wht 10-30 Vac/dc Wht/Prp Comm Gry N/C Prp Comm Brn N/O Wht/Org 208-277 Vac Gry/Wht 10-30 Vac/dc Wht/Prp Comm Gry N/C Prp Comm Brn N/O SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .75 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU2C) 39 mA @ 208-277 Vac (RIBH2C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 10 AMP PILOT CONTROL RELAYS RIBL3C Enclosed Relays 10 Amp 3 SPST-N/O with 10-30 Vac/dc Coil RIBL4C Enclosed Relays 10 Amp 3 SPST-N/O + 1 SPDT with 10-30 Vac/dc Coil Wht/Blk RELAY 1 Blk RELAY 1 Blk Wht/Blu RELAY 2 Blu RELAY 2 Blu Wht/Yel RELAY 3 Wht/Red COMM Yel RELAY 3 Yel · All relay coils use the same common · All relay coils 10-30 Vac/dc Wht/Blk RELAY 1 Wht/Blu RELAY 2 Wht/Yel RELAY 3 Wht/Brn RELAY 4 Wht/Red COMM · All relay coils use the same common · All relay coils 10-30 Vac/dc Blk RELAY 1 Blk Blu RELAY 2 Blu Yel RELAY 3 Yel Gry RELAY 4 Prp Brn Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Three (3) SPST Continuous Duty Coil (RIBL3C) Contact Ratings: Coil Current: Three (3) SPST + One (1) SPDT Continuous 10 Amp Resistive @ 277 Vac 33 mA @ 10 Vac 13 mA @ 10 Vdc Duty Coil (RIBL4C) 10 Amp Resistive @ 28 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc Expected Relay Life: 10 million cycles minimum mechanical 480 VA Pilot Duty @ 240-277 Vac 46 mA @ 24 Vac 18 mA @ 24 Vdc Operating Temperature: -30 to 140° F 480 VA Ballast @ 277 Vac 55 mA @ 30 Vac 20 mA @ 30 Vdc Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) Coil Voltage Input: 10-30 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Notes: · Order Normally Closed by adding "-NC" to end of model number Override Switch: No (800) 888-5538 | www.functionaldevices.com 5 10 AMP PILOT CONTROL RELAYS RIBU1S Enclosed Relay 10 Amp SPST-N/O + Override with 10-30 Vac/dc/120 Vac Coil RIBH1S Enclosed Relay 10 Amp SPST-N/O + Override with 10-30 Vac/dc/208-277 Vac Coil RELAYS Wht/Blk 120 Vac Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc CLOSED OPEN AUTO Wht/Blu 10-30 Vac/dc CLOSED OPEN AUTO Wht/Yel Wht/Yel Comm Org Comm Org Org Org Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1S) 39 mA @ 208-277 Vac (RIBH1S) Notes: · Order Normally Closed by adding "-NC" to end of model number 10 AMP PILOT CONTROL RELAYS RIBU1SM-250 Enclosed Relay 10 Amp SPST-N/O + Override + Monitor with 10-30 Vac/dc/120 Vac Coil RIBH1SM-250 Enclosed Relay 10 Amp SPST-N/O + Override + Monitor with 10-30 Vac/dc/208-277 Vac Coil AUTO COMM CLOSED AUTO COMM CLOSED Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO CLOSED OPEN AUTO Brn Prp Gry POLE 2 Org Org POLE 1 Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO CLOSED OPEN AUTO Brn Prp Gry POLE 2 Org Org POLE 1 Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes + Monitor Contact Ratings: 10 Amp Resistive @ 120/250 Vac 345 VA Pilot Duty @ 120/240 Vac 211 VA Pilot Duty @ 120/240 Vac 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) Coil Current: 55 mA @ 30 Vac 28 mA @ 120 Vac (RIBU1SM-250) 39 mA @ 208-277 Vac (RIBH1SM-250) 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 250 Vac max and 5 Amp max · Order Normally Closed by adding "-NC" to end of model number 6 Functional Devices, Inc. | American Made. American Owned. RELAYS 10 AMP PILOT CONTROL RELAYS RIB2401D Enclosed Relay 10 Amp DPDT with 24 Vac/dc/120 Vac Coil RIB2402D Enclosed Relay 10 Amp DPDT with 24 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Made in USA Meets "Buy American" of ARRA 2009 RIB2401D-RD RIB2402D-RD · Red housing RIB2401D-N4 RIB2402D-N4 · NEMA 4X housing, UL508 only SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max Coil Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 30 Vdc 31 mA @ 120 Vac (RIB2401D) 36 mA @ 208-277 Vac (RIB2402D) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401D) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402D) Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc 10 AMP PILOT CONTROL RELAYS RIBU1SC Enclosed Relay 10 Amp SPDT + Override with 10-30 Vac/dc/120 Vac Coil RIBH1SC Enclosed Relay 10 Amp SPDT + Override with 10-30 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Wht/Brn 208-277 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1SC) 39 mA @ 208-277 Vac (RIBH1SC) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc (800) 888-5538 | www.functionaldevices.com 7 RELAYS 10 AMP PILOT CONTROL RELAYS RIBL1C-DC Enclosed Relay 10 Amp SPDT with 10-30 Vdc Limited Inrush Coil Wht/Blu 10-30 Vdc Wht/Yel Comm Blu N/C Yel Comm Org N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No RIBL1C-DC-RD · Red housing RIBL1C-DC-N4 · NEMA 4X housing, UL508 only Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vdc Drop Out = 2.8 Vdc Pull In = 10 Vdc 10 AMP PILOT CONTROL RELAYS RIB2421C Enclosed Relay 10 Amp SPDT with 24 Vac/dc/120-277 Vac Coil Wht/Brn 120-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O RIB2421C-RD · Red housing RIB2421C-N4 · NEMA 4X housing, UL508 only GREAT SERVICE TRUCK RELAY ONE RELAY COVERS MOST APPLICATIONS Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 66 mA @ 24 Vac 38 mA @ 24 Vdc 40 mA @ 120-277 Vac Coil Voltage Input: 24 Vac/dc ; 120-277 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 8 Functional Devices, Inc. | American Made. American Owned. RELAYS 10 AMP PILOT CONTROL RELAY RIBD2421C Enclosed Time Delay Relay 10 Amp SPDT with 24 Vac/dc/120-277 Vac Coil Wht/Brn Blu 120-277 Vac N/C Wht/Blu 24 Vac/dc Yel Comm Wht/Yel Org Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms after time delay Relay Status: RED LED On = Activated Time Delay Status: PINK LED FLASHING = Timing Timing Mode: Delay On Make (N/O) Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Input Current: 66 mA @ 24 Vac 38 mA @ 24 Vdc 40 mA @ 120-277 Vac Coil Voltage Input: 24 Vac/dc ; 120-277 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Timing Adjustment C BD AE Range Selection 1234 Only Close 1 Switch Depressed for closed Depressed for open Switch Ranges 6s-20s 22s-1min15s 1min30s-5min 6min-20min Close Dip Switch 1 2 3 4 TIMING TABLE Potentiometer Setting A B C D 6s 9s 13s 16s 22s 36s 50s 1min4s 1min30s 2min10s 3min20s 4min16s 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min Coil Time Delay N/O N/C Time Delay Timing Diagram Time Delay Time Delay Time Delay Time Delay Time Delay Application Load 2 stays on selected amount of time after Load 1 goes off. Load 1 (Thermostat Controlled Heater, for example) In this example, voltage can be any voltage from 120-277 Vac. Blu Wht/Yel Neutral Blu Load 2 (Circulating Fan, for example) Yel RIB® Select RIB® with coil input appropriate to sense Load 1. Wht/Brn Yel RIBD2421C (800) 888-5538 | www.functionaldevices.com 9 RELAYS 10 AMP PILOT CONTROL RELAY RIBU2SC Enclosed Relays 10 Amp SPST-N/O + Override + 1 SPDT with 10-30 Vac/dc/120 Vac Coil Wht/Red Gry 120 Vac N/C Gry/Wht 10-30 Vac/dc Prp Comm Wht/Prp Brn Comm N/O Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO Org Org Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST + One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .75 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 10 AMP PILOT CONTROL RELAY RIBU2S2 Enclosed Relays 10 Amp 2 SPST-N/O + 2 Overrides with 10-30 Vac/dc/120 Vac Coil Wht/Blk 120 Vac Wht/Blu 10-30 Vac/dc CLOSED OPEN AUTO Wht/Yel Org Comm Org Wht/Red 120 Vac Gry/Wht 10-30 Vac/dc CLOSED OPEN AUTO Wht/Prp Brn Comm Brn SPECIFICATIONS # Relays & Contact Type: Two (2) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 28 mA @ 120 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc 10 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number RELAYS 10 AMP PILOT CONTROL RELAYS RIBTU1C Enclosed Relay Hi/Low Separation 10 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBTH1C Enclosed Relay Hi/Low Separation 10 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac Blu - N/C Yel - Comm Org - N/O Comm 10-30 Vac/dc 208-277 Vac Blu - N/C Yel - Comm Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1C) 39 mA @ 208-277 Vac (RIBTH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 10 AMP PILOT CONTROL RELAYS RIBTU2C Enclosed Relays Hi/Low Separation 10 Amp 2 SPDT with 10-30 Vac/dc/120 Vac Coil RIBTH2C Enclosed Relays Hi/Low Separation 10 Amp 2 SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac Comm 10-30 Vac/dc 120 Vac Comm 10-30 Vac/dc 208-277 Vac Comm 10-30 Vac/dc 208-277 Vac Blu - N/C Yel - Comm Org - N/O Brn - N/O Prp - Comm Gry - N/C Blu - N/C Yel - Comm Org - N/O Brn - N/O Prp - Comm Gry - N/C Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU2C) 39 mA @ 208-277 Vac (RIBTH2C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc (800) 888-5538 | www.functionaldevices.com 11 15 AMP PILOT CONTROL RELAYS RIBU1CW Enclosed Relay Hi/Low Separation 15 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBH1CW Enclosed Relay Hi/Low Separation 15 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil RELAYS Comm 10-30 Vac/dc 120 Vac N/O N/C Comm Comm 10-30 Vac/dc 208-277 Vac SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No N/O N/C Comm Contact Ratings: 15 Amp Resistive @ 150 Vac, 28Vdc 15 Amp Inductive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1CW) 39 mA @ 208-277 Vac (RIBH1CW) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBU1CW) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBH1CW) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 10 AMP PILOT CONTROL RELAYS RIBTU1S Enclosed Relay Hi/Low Separation 10 Amp SPST + Override with 10-30 Vac/dc/ 120 Vac Coil RIBTH1S Enclosed Relay Hi/Low Separation 10 Amp SPST + Override with 10-30 Vac/dc/ 208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac Selectable Jumper Wire Org CLOSED Org OPEN AUTO Comm 10-30 Vac/dc 208-277 Vac Selectable Jumper Wire Org CLOSED Org OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Notes: · Normally Open or Normally Closed selected by yellow jumper wire Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1S) 39 mA @ 208-277 Vac (RIBTH1S) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 12 Functional Devices, Inc. | American Made. American Owned. 10 AMP PILOT CONTROL RELAYS RIBTU1SC Enclosed Relay Hi/Low Separation 10 Amp SPDT + Override with 10-30 Vac/dc/ 120 Vac Coil Comm 10-30 Vac/dc Blu N/C N/C - CLOSED OPEN Org N/O N/O - CLOSED RIBTH1SC Enclosed Relay Hi/Low Separation 10 Amp SPDT + Override with 10-30 Vac/dc/ 208-277 Vac Coil Comm 10-30 Vac/dc Blu N/C N/C - CLOSED OPEN Org N/O N/O - CLOSED 120 Vac MANUAL AUTO Yel Comm 208-277 Vac MANUAL AUTO Yel Comm Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBTU1SC) 39 mA @ 208-277 Vac (RIBTH1SC) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 10 AMP PILOT CONTROL RELAY RIBT2401D Enclosed Relay Hi/Low Separation 10 Amp DPDT with 24 Vac/dc/120 Vac Coil 120 Vac 24 Vac/dc Comm Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max (800) 888-5538 | www.functionaldevices.com Coil Current: 24 mA @ 18 Vac 32 mA @ 24 Vac 40 mA @ 30 Vac 31 mA @ 120 Vac 20 mA @ 20 Vdc 24 mA @ 24 Vdc 36 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc 13 RELAYS 10 AMP TRACK MOUNT CONTROL RELAYS RIBAN24C Track Mount Relay 10 Amp SPDT with 24 Vac/dc Coil RIBAN12C Track Mount Relay 10 Amp SPDT with 12 Vac/dc Coil 24 Vac/dc 12 Vac/dc N/O N/O Comm Comm N/C N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.025 x 2.750 x 2.850 Terminals: Removable, Accepts 22-16 AWG copper wires Mounting: A: 2.750 Track Mount, See MT212 Series on page 152. MT212 Mounting Track Sold Separately. B: 35mm x 7.5mm symmetrical DIN rail EN50022 C: Screw Mount, See DS80625 on page 153. DS80625 Self-Tapping Drill Screws Sold Separately. D: Current Sensor Mount, See RIBXG Series on page 94 or RIBXK Series on page 93. Current Sensors Sold Separately. Approvals: UL Listed, UL508, C-UL, CE, RoHS Gold Flash: No Override Switch: No RELAY MOUNTING OPTIONS A & B Mounting Option A: 2.75" Track Mount MT212 Series K G Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Voltage Input (RIBAN24C): 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Coil Voltage Input (RIBAN12C): 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Made in USA Meets "Buy American" of ARRA 2009 REMOVABLE TERMINALS Coil Current (RIBAN24C): 26 mA @ 20 Vac 31 mA @ 24 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Current (RIBAN12C): 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc Notes: · Set of replacement terminals available. Order model number: TS-AN Mounting Option B: K G 35mm x 7.5mm symmetrical DIN rail EN50022 CURRENT SENSOR MOUNTING OPTION D K RIBXK Series Mounting Tab G RIBXG Series Mounting Tab 1. Slide current sensor onto corresponding mounting tab. 2. Snap into place. 3. Depress tab to remove current sensor. 14 Functional Devices, Inc. | American Made. American Owned. RELAYS 15 AMP TRACK MOUNT CONTROL RELAYS RIBM12C 4.00 Track Mount Relay 15 Amp SPDT with 12 Vac/dc Coil RIBM12S 4.00 Track Mount Relay 15 Amp SPST + Override with 12 Vac/dc Coil Comm 12 Vac/dc N/C Comm N/O Comm 12 Vac/dc AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBM12C) One (1) SPST Continuous Duty Coil (RIBM12S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBM12C) Yes (RIBM12S) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Made in USA Meets "Buy American" of ARRA 2009 Cut for N/O Cut for N/C Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 36 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBM12S) 15 AMP TRACK MOUNT CONTROL RELAYS RIBM24C 4.00 Track Mount Relay 15 Amp SPDT with 24 Vac/dc Coil RIBM24S 4.00 Track Mount Relay 15 Amp SPST + Override with 24 Vac/dc Coil Comm N/C Comm AUTO OPEN CLOSED Comm Made in USA Meets "Buy American" of ARRA 2009 24 Vac/dc Comm N/O SPECIFICATIONS 24 Vac/dc N/O or N/C Selectable Jumpers (must cut one only) Cut for N/O Cut for N/C # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBM24C) One (1) SPST Continuous Duty Coil (RIBM24S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBM24C) Yes (RIBM24S) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBM24S) (800) 888-5538 | www.functionaldevices.com 15 RELAYS 10 AMP TRACK MOUNT CONTROL RELAYS RIBM2401D 4.00 Track Mount Relay 10 Amp DPDT with 24 Vac/dc/120 Vac Coil RIBM2402D 4.00 Track Mount Relay 10 Amp DPDT with 24 Vac/dc/208-277 Vac Coil 120 Vac 24 Vac/dc Comm N/O Comm N/C N/O Comm N/C 208-277 Vac 24 Vac/dc Comm N/O Comm N/C N/O Comm N/C Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.700 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max Coil Current: 24 mA @ 18 Vac 20 mA @ 20 Vdc 32 mA @ 24 Vac 24 mA @ 24 Vdc 40 mA @ 30 Vac 36 mA @ 30 Vdc 31 mA @ 120 Vac (RIBM2401D) 36 mA @ 208-277 Vac (RIBM2402D) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401D) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402D) Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU1C 4.00 Track Mount Relay 15 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBMH1C 4.00 Track Mount Relay 15 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac N/C Comm N/O Comm 10-30 Vac/dc 208-277 Vac N/C Comm N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Inductive @ 150 Vac 15 Amp Resistive @ 150 Vac, 28 Vdc 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1C) 39 mA @ 208-277 Vac (RIBMH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 16 Functional Devices, Inc. | American Made. American Owned. 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU1S 4.00 Track Mount Relay 15 Amp SPST-N/O + Override with 10-30 Vac/dc/120 Vac Coil RIBMH1S 4.00 Track Mount Relay 15 Amp SPST-N/O + Override with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac AUTO OPEN CLOSED Comm 10-30 Vac/dc 208-277 Vac AUTO OPEN CLOSED Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.275 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1S) 39 mA @ 208-277 Vac (RIBMH1S) Notes: · Order Normally Closed by adding "-NC" to end of model number 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU2C 4.00 Track Mount Relays 15 Amp 2 SPDT with 10-30 Vac/dc/120 Vac Coil RIBMH2C 4.00 Track Mount Relays 15 Amp 2 SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm N/C Comm N/C 10-30 Vac/dc Comm 10-30 Vac/dc Comm 120 Vac N/O Comm N/C 208-277 Vac N/O Comm N/C 10-30 Vac/dc Comm 10-30 Vac/dc Comm 120 Vac N/O 208-277 Vac N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Inductive @ 150 Vac 15 Amp Resistive @ 150 Vac, 28 Vdc 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) (800) 888-5538 | www.functionaldevices.com Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU2C) 39 mA @ 208-277 Vac (RIBMH2C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU2C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH2C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 17 RELAYS 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU1SM-250 4.00 Track Mount Relay 15 Amp SPST + Override + Monitor with 10-30 Vac/dc/ 120 Vac Coil RIBMH1SM-250 4.00 Track Mount Relay 15 Amp SPST + Override + Monitor with 10-30 Vac/dc/ 208-277 Vac Coil Closed Comm Auto Comm CLOSED OPEN AUTO Selectable Jumper Wire Closed Comm Auto Comm CLOSED OPEN AUTO Selectable Jumper Wire 10-30 Vac/dc 120 Vac CLOSED OPEN AUTO 10-30 Vac/dc 208-277 Vac CLOSED OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.000 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes + Monitor Contact Ratings: 15 Amp Resistive @ 125 Vac 10 Amp Resistive @ 250 Vac 345 VA Pilot Duty @ 120/240 Vac (N/O) 211 VA Pilot Duty @ 120/240 Vac (N/C) 1/3 HP for N/O @ 120-240 Vac 1/6 HP for N/C @ 120-240 Vac Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1SM-250) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1SM-250) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1SM-250) 39 mA @ 208-277 Vac (RIBMH1SM-250) Notes: · Normally Open or Normally Closed selected by yellow jumper wire · Second pole of override switch can be connected to digital-in of controller to report position of override switch · Rating of second pole is 50 Vac/dc, 0.25 Amp max 15 AMP TRACK MOUNT CONTROL RELAYS RIBMU1SC 4.00 Track Mount Relay 15 Amp SPDT + Override with 10-30 Vac/dc/120 Vac Coil RIBMH1SC 4.00 Track Mount Relay 15 Amp SPDT + Override with 10-30 Vac/dc/208-277 Vac Coil Comm Comm Made in USA Meets "Buy American" of ARRA 2009 10-30 Vac/dc 120 Vac AUTO MANUAL N/O CLOSED N/C CLOSED OPEN Comm N/C N/O 10-30 Vac/dc 208-277 Vac AUTO MANUAL N/O CLOSED N/C CLOSED OPEN Comm N/C N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.500 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes (2) Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMU1SC) 39 mA @ 208-277 Vac (RIBMH1SC) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMU1SC) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMH1SC) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 18 Functional Devices, Inc. | American Made. American Owned. RELAYS 15 AMP TRACK MOUNT CONTROL RELAYS RIBMN12C 2.75 Track Mount Relay 15 Amp SPDT with 12 Vac/dc Coil RIBMN12S 2.75 Track Mount Relay 15 Amp SPST + Override with 12 Vac/dc Coil Comm 12 Vac/dc N/C Comm N/O Comm 12 Vac/dc AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN12C) One (1) SPST Continuous Duty Coil (RIBMN12S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.100 x 2.750 x 1.750 (RIBMN12C) 1.250 x 2.750 x 1.750(RIBMN12S) Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN12C) Yes (RIBMN12S) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Made in USA Meets "Buy American" of ARRA 2009 Cut for N/O Cut for N/C Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN12S) 15 AMP TRACK MOUNT CONTROL RELAYS RIBMN24C 2.75 Track Mount Relay 15 Amp SPDT with 24 Vac/dc Coil RIBMN24S 2.75 Track Mount Relay 15 Amp SPST + Override with 24 Vac/dc Coil Made in USA Meets "Buy American" of ARRA 2009 Comm N/C Comm AUTO OPEN CLOSED Comm Comm N/O or N/C 24 Vac/dc Cut for N/O 24 Vac/dc N/O Selectable Jumpers (must cut one only) Cut for N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBMN24C) One (1) SPST Continuous Duty Coil (RIBMN24S) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.100 x 2.750 x 1.750 (RIBMN24C) 1.250 x 2.750 x 1.750 (RIBMN24S) Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN24C) Yes (RIBMN24S) (800) 888-5538 Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S) | www.functionaldevices.com 19 RELAYS 15 AMP TRACK MOUNT CONTROL RELAY RIBMN24S-J 2.75 Track Mount Relay 15 Amp SPST + Override with 24 Vac/dc Coil and Jumper Selectable Output Comm AUTO OPEN CLOSED 24 Vac/dc Selectable Jumper Wire SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.250 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Normally Open or Normally Closed selected by yellow jumper wire. 15 AMP TRACK MOUNT CONTROL RELAYS RIBMN24C-4T Four 2.75 Track Mount Relays 15 Amp SPDT with 24 Vac/dc Coil and 2.75 x 6.00 Mounting Track RIBMN24S-4T Four 2.75 Track Mount Relays 15 Amp SPST + Override with 24 Vac/dc Coil and 2.75 x 6.00 Mounting Track Comm 24 Vac/dc N/C Comm N/O Comm 24 Vac/dc AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Four (4) SPDT Continuous Duty Coils (RIBMN24C-4T) Four (4) SPST Continuous Duty Coils (RIBMN24S-4T) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 6.000 x 2.750 x 1.150 (RIBMN24C-4T) 6.000 x 2.750 x 1.500 (RIBMN24S-4T) Track Mount: 2.750 x 6.000 ; MT212-6 Mounting Track Included Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN24C-4T) Yes (RIBMN24S-4T) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac C300 Pilot Duty Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S-4T) 20 Functional Devices, Inc. | American Made. American Owned. RELAYS 10 AMP TRACK MOUNT CONTROL RELAY RIBMN2401D 2.75 Track Mount Relay 10 Amp DPDT with 24 Vac/dc/120 Vac Coil 120 Vac 24 Vac/dc Comm N/O Comm N/C N/O Comm N/C SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Relay Status: LED On = Activated Dimensions: 1.700 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 10 Amp Resistive @ 30 Vdc 10 Amp General Use @ 277 Vac 1/2 HP @ 120/240 Vac (N/O) 1/3 HP @ 120/240 Vac (N/C) B300 Pilot Duty 120 Vac 30A Make 3A Break (360 VA) 240 Vac 15 A Make 1.5A Break (360 VA) 208 Vac 17.3A Make 1.73A Break (360 VA) 277 Vac 13A Make 1.3A Break (360 VA) 24 Vac 30A Make 5A Break (120VA) 5A Max Coil Current: 36 mA @ 30Vdc 24 mA @ 18 Vac 32 mA @ 24 Vac 40 mA @ 30 Vac 31 mA @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 18 Vac / 20 Vdc 15 AMP TRACK MOUNT CONTROL RELAYS RIBMNU1C 2.75 Track Mount Relay 15 Amp SPDT with 10-30 Vac/dc/120 Vac Coil RIBMNH1C 2.75 Track Mount Relay 15 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac N/C Comm N/O Comm 10-30 Vac/dc 208-277 Vac N/C Comm N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.700 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 15 Amp Resistive @ 150 Vac, 28Vdc 15 Amp Inductive @ 150 Vac 10 Amp Resistive @ 120-277 Vac, 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) (800) 888-5538 | www.functionaldevices.com Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMNU1C) 39 mA @ 208-277 Vac (RIBMNH1C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1C) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1C) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc 21 RELAYS 15 AMP TRACK MOUNT CONTROL RELAYS RIBMNU1S 2.75 Track Mount Relay 15 Amp SPST + Override with 10-30 Vac/dc/120 Vac Coil RIBMNH1S 2.75 Track Mount Relay 15 Amp SPST + Override with 10-30 Vac/dc/208-277 Vac Coil Comm 10-30 Vac/dc 120 Vac AUTO OPEN CLOSED Selectable Jumper Wire Comm 10-30 Vac/dc 208-277 Vac AUTO OPEN CLOSED Selectable Jumper Wire Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.500 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: Yes Contact Ratings: 15 Amp Resistive @ 150 Vac 10 Amp Resistive @ 277 Vac 480 VA Pilot Duty @ 277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac ; 50-60 Hz (RIBMNU1S) 10-30 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBMNH1S) Drop Out = 2.1 Vac / 2.8 Vdc Pull In = 9 Vac / 10 Vdc Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBMNU1S) 39 mA @ 208-277 Vac (RIBMNH1S) Notes: · Normally Open or Normally Closed selected by yellow jumper wire 22 Functional Devices, Inc. | American Made. American Owned. POWER RELAYS: 2030 AMPS Enclosed | T Style | Track Mount Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). RELAYS ENCLOSED POWER RELAYS COIL VOLTAGE MODEL # RIB2401B AC/DC · 24 RIB2402B · 24 RIB2401SB · 24 RIB2402SB · 24 RIB2421B · 24 RIB2421SB · 24 RIB01P · RIB02P · RIB347P · RIB04P · RIB2401SBC · 24 RIB2402SBC · 24 RIB243P · 3 24 RIB013P · RIB023P · RIB043P · RIB24Z · 24 RIB12P · 12 RIB12P30 · 12 RIB24P · 24 RIB24P30 · 24 RIB01P30 · RIB01P30-S · RIB02P30 · AC 120 208-277 120 208-277 120/208-277 120/208-277 120 208-277 347 480 120 208-277 120 208-277 480 120 120 208-277 T STYLE POWER RELAYS COIL VOLTAGE MODEL # RIBT24B · RIBT2401B · RIBTD2401B · RIBT2402B · RIBT242B · RIBT243B · 3 RIBT24SB · RIBT2401SB · RIBT2402SB · RIBT2401SBC · RIBT2402SBC · RIBT24P · RIBT24Z · RIBT243P · 3 AC/DC 24 24 24 24 24 24 24 24 24 24 24 24 24 24 AC 120 120 208-277 120 208-277 120 208-277 RELAYS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CONTACTS SPDT SPDT SPST SPST SPDT SPST DPDT DPDT DPDT DPDT SPDT SPDT 3PST 3PST 3PST 3PST 1 SPST N/O, 1 SPST N/C DPDT DPDT DPDT DPDT DPST DPST DPST OVERRIDE SWITCH 1 1 1 2 1 2 1 1 NOTES NEW SPEC PAGE 24 24 25 25 25 25 26 27 27 28 26 26 28 29 29 30 30 31 31 31 31 32 32 32 RELAYS 1 1 1 1 2 3 1 1 1 1 1 1 1 1 CONTACTS SPDT SPDT SPDT SPDT 2 SPDT 2 SPST, 1 SPDT SPST SPST SPST SPDT SPDT DPDT 1 SPST N/O, 1 SPST N/C 3PST OVERRIDE SWITCH 1 1 1 2 1 2 1 NOTES 2 SPEC PAGE 33 33 35 33 36 36 33 34 34 34 34 36 37 37 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 3 = UL Listed : UL916 Energy Management ; USA & Canada 1 = SPDT with override requires 2 switches (800) 888-5538 | www.functionaldevices.com 2 = Time Delay 23 RELAYS TRACK MOUNT POWER RELAYS COIL VOLTAGE MODEL # AC/DC AC RIBM2401B · 24 120 RIBM2402B · 24 208-277 RIBM2401SB · 24 120 RIBM2402SB · 24 208-277 RIBM2401SBC · 24 120 RIBM2402SBC · 24 208-277 RIBM24ZN 24 RIBM24ZL · 24 RIBMN24ZL · 24 RIBM243PN 24 RIBM013PN 120 RIBM023PN 208-277 RIBM043PN 480 RIBM043PN-HD 480 RELAYS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada = UL Component Recognized : UL916 Energy Management; USA & Canada CONTACTS SPDT SPDT SPST SPST SPDT SPDT DPDT DPST DPST 3PDT 3PDT 3PDT 3PDT 3PDT OVERRIDE SWITCH 1 1 2 1 2 1 NOTES 1 = SPDT with override requires 2 switches SPEC PAGE 38 38 38 38 39 39 39 40 40 41 41 42 42 43 20 AMP POWER CONTROL RELAYS RIB2401B Enclosed Relay 20 Amp SPDT with 24 Vac/dc/120 Vac Coil RIB2402B Enclosed Relay 20 Amp SPDT with 24 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIB2401B) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIB2402B) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 24 Functional Devices, Inc. | American Made. American Owned. RELAYS 20 AMP POWER CONTROL RELAYS RIB2401SB Enclosed Relay 20 Amp SPST-N/O + Override with 24 Vac/dc/120 Vac Coil RIB2402SB Enclosed Relay 20 Amp SPST-N/O + Override with 24 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc CLOSED OPEN AUTO Wht/Blu 24 Vac/dc CLOSED OPEN AUTO Wht/Yel Wht/Yel Comm Org Comm Org Org Org SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, UL508, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIB2401SB) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIB2402SB) Notes: · Order Normally Closed by adding "-NC" to end of model number 20 AMP POWER CONTROL RELAYS RIB2421B Enclosed Relay 20 Amp with 24 Vac/dc/208-277 Vac/120 Vac Coil RIB2421SB Enclosed Relay 20 Amp + Override with 24 Vac/dc/208-277 Vac/120 Vac Coil Made in USA Meets "Buy American" of ARRA 2009 Wht/Brn 208-277 Vac Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm Blu N/C Yel Comm Org N/O Wht/Brn 208-277 Vac Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm CLOSED OPEN AUTO Org Org GREAT SERVICE TRUCK RELAY ONE RELAY COVERS MOST APPLICATIONS SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIB2421B) One (1) SPST Continuous Duty Coil (RIB2421SB) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIB2421B) Yes (RIB2421SB) Contact Ratings (RIB2421B): 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 83 mA @ 24 Vac 47 mA @ 120 Vac 69 mA @ 208-277 Vac 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 208-277 Vac ; 120 Vac ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Contact Ratings (RIB2421SB): 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number (RIB2421SB) (800) 888-5538 | www.functionaldevices.com 25 RELAYS 20 AMP POWER CONTROL RELAYS RIB2401SBC Enclosed Relay 20 Amp SPDT + Override with 24 Vac/dc/120 Vac Coil RIB2402SBC Enclosed Relay 20 Amp SPDT + Override with 24 Vac/dc/208-277 Vac Coil Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIB2401SBC) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIB2402SBC) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 20 AMP POWER CONTROL RELAY RIB01P Enclosed Relay 20 Amp DPDT with 120 Vac Coil Wht/Blk 120 Vac Wht/Blk 120 Vac Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 105 mA @ 120 Vac 26 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac RELAYS 20 AMP POWER CONTROL RELAY RIB02P Enclosed Relay 20 Amp DPDT with 208-277 Vac Coil Wht/Brn 208-277 Vac Wht/Brn 208-277 Vac Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 105 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac 20 AMP POWER CONTROL RELAY RIB347P Enclosed Relay 20 Amp DPDT with 347 Vac Coil Wht/Org 347 Vac Wht/Org 347 Vac Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O LIGHTING RETROFITS 347 VAC FOR OUR FRIENDS IN CANADA SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 105 mA @ 347 Vac Coil Voltage Input: 347 Vac ; 50-60 Hz Drop Out = 70 Vac Pull In = 295 Vac 27 RELAYS 20 AMP POWER CONTROL RELAY RIB04P Enclosed Relay 20 Amp DPDT with 480 Vac Coil Wht/Grn 480 Vac Wht/Grn 480 Vac Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 105 mA @ 480 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac 20 AMP POWER CONTROL RELAY RIB243P Enclosed Relay 20 Amp 3PST-N/O with 24 Vac/dc Coil Wht/Yel 24 Vac/dc Blu - N/O Blu - N/O Wht/Yel 24 Vac/dc Yel - N/O Yel - N/O Org - N/O Org - N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Contact Ratings: Coil Current: Expected Relay Life: 10 million cycles minimum mechanical 20 Amp Resistive @ 300 Vac, 28 Vdc 210 mA @ 24 Vac Operating Temperature: -30 to 140° F 20 Amp Ballast @ 277-480 Vac 154 mA @ 30 Vdc Humidity Range: 5 to 95% (noncondensing) Not rated for Electronic Ballast Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc California State Fire Marshal, CE, RoHS 1466 VA Pilot Duty @ 240 Vac, 3 Phase Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase Notes: · Order Normally Closed by adding "-NC" to end of model number 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase 28 Functional Devices, Inc. | American Made. American Owned. 20 AMP POWER CONTROL RELAY RIB013P Enclosed Relay 20 Amp 3PST-N/O with 120 Vac Coil RELAYS Wht/Blk 120 Vac Wht/Blk 120 Vac Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No 20 AMP POWER CONTROL RELAY RIB023P Enclosed Relay 20 Amp 3PST-N/O with 208-277 Vac Coil Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Wht/Brn 208-277 Vac Wht/Brn 208-277 Vac Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 154 mA @ 120 Vac Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 187 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number 29 RELAYS 20 AMP POWER CONTROL RELAY RIB043P Enclosed Relay 20 Amp 3PST-N/O with 480 Vac Coil Wht/Grn 480 Vac Wht/Grn 480 Vac Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 132 mA @ 480 Vac Coil Voltage Input: 480 Vac ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac Notes: · Order Normally Closed by adding "-NC" to end of model number 30 AMP POWER CONTROL RELAY RIB24Z Enclosed Relay 30 Amp SPST-N/O + SPST-N/C with 24 Vac/dc Coil Wht/Yel Blu 24 Vac/dc N/C Blu N/C Org N/O Wht/Yel 24 Vac/dc Org N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPST-N/O + SPST-N/C Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc 30 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 20 / 30 AMP POWER CONTROL RELAYS RIB12P Enclosed Relay 20 Amp DPDT with 12 Vac/dc Coil RIB12P30 Enclosed Relay 30 Amp DPDT with 12 Vac/dc Coil Wht/Yel 12 Vac/dc Wht/Yel 12 Vac/dc Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Wht/Yel 12 Vac/dc Wht/Yel 12 Vac/dc Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIB12P) 2.30 x 3.20 x 1.80 with .75 NPT Nipple (RIB12P30) Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: (RIB12P) 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Contact Ratings: (RIB12P30) 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 115 mA @ 10 Vac 180 mA @ 12 Vac 79 mA @ 11 Vdc 90 mA @ 12 Vdc 115 mA @ 15 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 4.5 Vac / 4.8 Vdc Pull In = 9.7 Vac / 11 Vdc 20 / 30 AMP POWER CONTROL RELAYS RIB24P Enclosed Relay 20 Amp DPDT with 24 Vac/dc Coil RIB24P30 Enclosed Relay 30 Amp DPDT with 24 Vac/dc Coil Wht/Yel 24 Vac/dc Wht/Yel 24 Vac/dc Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Wht/Yel 24 Vac/dc Wht/Yel 24 Vac/dc Blu N/C Yel Comm Org N/O Gry N/C Prp Comm Brn N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIB24P) 2.30 x 3.20 x 1.80 with .75 NPT Nipple (RIB24P30) Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, UL60947, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: (RIB24P) 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Contact Ratings: (RIB24P30) 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 31 RELAYS 30 AMP POWER CONTROL RELAYS RIB01P30 Enclosed Relay 30 Amp DPST-N/O with 120 Vac Coil RIB01P30-S Enclosed Relay 30 Amp DPST-N/O + Coil Side Override with 120 Vac Coil Org Org N/O N/O Wht/Blk 120 Vac Wht/Blk 120 Vac Continuous HAND Org N/O Wht/Red OFF Org N/O 120 Vac Control AUTO Brn Brn N/O N/O Wht/Blk 120 Vac Wht/Yel Brn Neutral Brn N/O N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No (RIB01P30) Coil Side (RIB01P30-S) Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 105 mA @ 120 Vac Control Input: (RIB01P30-S) Wht/Blk = 120 Vac Continuous Wht/Red = 120 Vac Control Wht/Yel = Neutral Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac Notes: · Order Both Poles Normally Closed by adding "-NC" to end of model number · Order Pole 1 Normally Open and Pole 2 Normally Closed by adding "-NONC" to end of model number 30 AMP POWER CONTROL RELAY RIB02P30 Enclosed Relay 30 Amp DPST-N/O with 208-277 Vac Coil Wht/Brn 208-277 Vac Wht/Brn 208-277 Vac Org N/O Pole 1 Org N/O Brn N/O Pole 2 Brn N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 105 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac Notes: · Order Both Poles Normally Closed by adding "-NC" to end of model number · Order Pole 1 Normally Open and Pole 2 Normally Closed by adding "-NONC" to end of model number 32 Functional Devices, Inc. | American Made. American Owned. RELAYS 20 AMP POWER CONTROL RELAYS RIBT24B Enclosed Relay Hi/Low Separation 20 Amp SPDT with 24 Vac/dc Coil RIBT24SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override with 24 Vac/dc Coil 24 Vac/dc Comm Blu N/C Yel Comm Org N/O 24 Vac/dc Comm Selectable Jumper Wire Org CLOSED Org OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil (RIBT24B) One (1) SPST Continuous Duty Coil (RIBT24SB) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIBT24B) Yes (RIBT24SB) Contact Ratings (RIBT24B): 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 45 mA @ 18 Vac 75 mA @ 24 Vac 30 mA @ 22 Vdc 32 mA @ 24 Vdc 42 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Contact Ratings (RIBT24SB): 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Notes: · Normally Open or Normally Closed selected by yellow jumper wire (RIBT24SB) 20 AMP POWER CONTROL RELAYS RIBT2401B Enclosed Relay Hi/Low Separation 20 Amp SPDT with 24 Vac/dc/120 Vac Coil RIBT2402B Enclosed Relay Hi/Low Separation 20 Amp SPDT with 24 Vac/dc/208-277 Vac Coil 120 Vac 24 Vac/dc Comm Blu N/C Yel Comm Org N/O 208-277 Vac 24 Vac/dc Comm Blu N/C Yel Comm Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBT2401B) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBT2402B) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 33 RELAYS 20 AMP POWER CONTROL RELAYS RIBT2401SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override with 24 Vac/dc/120 Vac Coil RIBT2402SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override with 24 Vac/dc/208-277 Vac Coil Selectable Jumper Wire Selectable Jumper Wire 120 Vac Org 208-277 Vac Org Made in USA Meets "Buy American" of ARRA 2009 24 Vac/dc Comm CLOSED Org OPEN AUTO 24 Vac/dc Comm CLOSED Org OPEN AUTO SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401SB) 69 mA @ 208-277 Vac (RIBT2402SB) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Notes: · Normally Open or Normally Closed selected by yellow jumper wire 20 AMP POWER CONTROL RELAYS RIBT2401SBC Enclosed Relay Hi/Low Separation 20 Amp SPDT + Override with 24 Vac/dc/120 Vac Coil RIBT2402SBC Enclosed Relay Hi/Low Separation 20 Amp SPDT + Override with 24 Vac/dc/208-277 Vac Coil 120 Vac 24 Vac/dc Comm 208-277 Vac 24 Vac/dc Comm Made in USA Meets "Buy American" of ARRA 2009 Yel MANUAL Comm AUTO Blu N/C - CLOSED N/C OPEN Org N/O - CLOSED N/O Yel MANUAL Comm AUTO Blu N/C - CLOSED N/C OPEN Org N/O - CLOSED N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBT2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBT2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIBT2401SBC) 69 mA @ 208-277 Vac (RIBT2402SBC) 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc 34 Functional Devices, Inc. | American Made. American Owned. 20 AMP TIME DELAY RELAY RIBTD2401B Enclosed Time Delay Relay 20 Amp SPDT with 24 Vac/dc/120 Vac Coil RELAYS 120 Vac 24 Vac/dc Comm Blu N/C Yel Comm Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms after time delay Relay Status: RED LED On = Activated Time Delay Status: PINK LED FLASHING = Timing Timing Mode: Delay On Make (N/O) Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: Input Current: 20 Amp Resistive @ 277 Vac 133 mA @ 24 Vac 20 Amp Ballast @ 277 Vac 45 mA @ 24 Vdc 16 Amp Electronic Ballast @ 277 Vac (N/O) 51 mA @ 120 Vac 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Timing Adjustment Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc C BD AE Range Selection 1234 Only Close 1 Switch Depressed for closed Depressed for open Switch Ranges 6s-20s 22s-1min15s 1min30s-5min 6min-20min TIMING TABLE Close Dip Switch A Potentiometer Setting B C D 1 6s 9s 13s 16s 2 22s 36s 50s 1min4s 3 1min30s 2min10s 3min20s 4min16s 4 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min Time Delay Application Example #1 Load 2 stays ON selected amount of time after Load 1 turns ON (N/C) Load 2 stays OFF selected amount of time after Load 1 turns ON (N/O) Load 1 (Thermostat Controlled Heater, for example) 120 Vac Blu Time Delay Application Example #2 (Requires an Inverting Relay) Load 2 stays ON selected amount of time after Load 1 turns OFF (N/C) Load 2 stays OFF selected amount of time after Load 1 turns OFF (N/O) 120 Vac Hot Load 1 (Thermostat Blu Controlled Heater, for example) Blu Load 2 (Circulating Fan, for example) Load 1 Voltage Load 2 on N/O Contact Load 2 on N/C Contact Yel RIBTD2401B Time Delay Time Delay Load 2 (Circulating Fan, for example) Yel RIB® Select RIB® with coil input appropriate to sense Load 1. Present Absent ON OFF ON OFF Load 1 Voltage Load 2 on N/O Contact Load 2 on N/C Contact (800) 888-5538 | www.functionaldevices.com Yel RIBTD2401B Neutral Time Delay Time Delay Present Absent ON OFF ON OFF 35 RELAYS 20 AMP POWER CONTROL RELAYS RIBT242B Enclosed Relays Hi/Low Separation 20 Amp 2 SPDT with 24 Vac/dc Coil RELAY 2 24 Vac/dc Gry - N/C Prp - Comm RELAY 1 24 Vac/dc Brn - N/O Blu - N/C Comm Yel - Comm Org - N/O All relay coils use the same common RIBT243B Enclosed Relays Hi/Low Separation 20 Amp 2 SPST + 1 SPDT with 24 Vac/dc Coil RELAY 3 24 Vac/dc Gry - N/C Prp - Comm RELAY 2 24 Vac/dc Brn - N/O Yel - N/O RELAY 1 24 Vac/dc Yel - N/O Blu - N/O Comm Blu - N/O All relay coils use the same common Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil (RIBT242B) Two (2) SPST + One (1) SPDT Continuous Duty Coil (RIBT243B) Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Notes: · RIBT243B not rated for UL864. 20 AMP POWER CONTROL RELAY RIBT24P Enclosed Relay Hi/Low Separation 20 Amp DPDT with 24 Vac/dc Coil 24 Vac/dc Comm Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 36 Functional Devices, Inc. | American Made. American Owned. RELAYS 30 AMP POWER CONTROL RELAY RIBT24Z Enclosed Relay Hi/Low Separation 30 Amp SPST-N/O + SPST-N/C with 24 Vac/dc Coil 24 Vac/dc Comm Blu - N/C Blu - N/C Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPST-N/O + One (1) SPST-N/C Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Made in USA Meets "Buy American" of ARRA 2009 Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 20 AMP POWER CONTROL RELAY RIBT243P Enclosed Relay Hi/Low Separation 20 Amp 3PST-N/O with 24 Vac/dc Coil 24 Vac/dc Comm Blu - N/O Blu - N/O Yel - N/O Yel - N/O Org - N/O Org - N/O SPECIFICATIONS # Relays & Contact Type: One (1) 3PST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac, 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac, 1 Phase 1158 VA Pilot Duty @ 240 Vac, 1 Phase 1110 VA Pilot Duty @ 277 Vac, 1 Phase 1640 VA Pilot Duty @ 480 Vac, 1 Phase 1466 VA Pilot Duty @ 240 Vac, 3 Phase 2112 VA Pilot Duty @ 480 Vac, 3 Phase Heavy Pilot Duty @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 210 mA @ 24 Vac 154 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 37 RELAYS 20 AMP TRACK MOUNT CONTROL RELAYS RIBM2401B 4.00 Track Mount Relay 20 Amp SPDT with 24 Vac/dc/120 Vac Coil RIBM2402B 4.00 Track Mount Relay 20 Amp SPDT with 24 Vac/dc/208-277 Vac Coil Comm 24 Vac/dc Comm N/O Comm 24 Vac/dc Comm N/O Made in USA Meets "Buy American" of ARRA 2009 120 Vac N/C 208-277 Vac N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBM2401B) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBM2402B) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401B) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402B) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 20 AMP TRACK MOUNT CONTROL RELAYS RIBM2401SB 4.00 Track Mount Relay 20 Amp SPST + Override with 24 Vac/dc/120 Vac Coil RIBM2402SB 4.00 Track Mount Relay 20 Amp SPST + Override with 24 Vac/dc/208-277 Vac Coil Comm Selectable Jumper Wire Comm Selectable Jumper Wire 24 Vac/dc 24 Vac/dc 120 Vac CLOSED OPEN AUTO Not Used 208-277 Vac CLOSED OPEN AUTO Not Used Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.600 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBM2401SB) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBM2402SB) Notes: · Normally Open or Normally Closed selected by yellow jumper wire Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401SB) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402SB) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc 38 Functional Devices, Inc. | American Made. American Owned. 20 AMP TRACK MOUNT CONTROL RELAYS RIBM2401SBC 4.00 Track Mount Relay 20 Amp SPDT + Override with 24 Vac/dc/120 Vac Coil RIBM2402SBC 4.00 Track Mount Relay 20 Amp SPDT + Override with 24 Vac/dc/208-277 Vac Coil Comm 24 Vac/dc 120 Vac AUTO MANUAL N/C N/O CLOSED CLOSED OPEN Comm N/O N/C Comm 24 Vac/dc 208-277 Vac AUTO MANUAL N/C N/O CLOSED CLOSED OPEN Comm N/O N/C Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.350 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes (2) 30 AMP TRACK MOUNT CONTROL RELAY RIBM24ZN 4.00 Track Mount Relay 30 Amp DPDT with 24 Vac/dc Coil 24 Vac/dc Comm N/C N/O Comm N/C N/O Comm Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBM2401SBC) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBM2402SBC) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBM2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBM2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 1.600 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac NEMA B600 Pilot Duty Coil Current: 110 mA @ 20 Vac 125 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 70 mA @ 30 Vdc (800) 888-5538 | www.functionaldevices.com Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 39 RELAYS 30 AMP TRACK MOUNT CONTROL RELAY RIBM24ZL 4.00 Track Mount Relay 30 Amp DPST-N/O with 24 Vac/dc Coil Comm 24 Vac/dc Comm N/O Comm N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.350 x 4.000 x 2.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 30 AMP TRACK MOUNT CONTROL RELAY RIBMN24ZL 2.75 Track Mount Relay 30 Amp DPST-N/O with 24 Vac/dc Coil Comm 24 Vac/dc Comm N/O Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.350 x 2.750 x 2.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1109 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac Heavy Pilot Duty @ 600 Vac Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number 40 Functional Devices, Inc. | American Made. American Owned. RELAYS 30 AMP TRACK MOUNT CONTROL RELAY RIBM243PN 4.00 Track Mount Relay 30 Amp 3PDT with 24 Vac/dc Coil N/C N/O Comm N/C 24 Vac/dc Comm N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 190 mA @ 24 Vac 140 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 22 Vdc 30 AMP TRACK MOUNT CONTROL RELAY RIBM013PN 4.00 Track Mount Relay 30 Amp 3PDT with 120 Vac Coil N/C N/O Comm N/C Comm Not Used 120 Vac N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Coil Current: 140 mA @ 120 Vac Coil Voltage Input: 120 Vac ; 50-60 Hz Drop Out = 35 Vac Pull In = 85 Vac 41 RELAYS 30 AMP TRACK MOUNT CONTROL RELAY RIBM023PN 4.00 Track Mount Relay 30 Amp 3PDT with 208-277 Vac Coil N/C N/O Comm N/C Comm Not Used 208-277 Vac N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase Coil Current: 170 mA @ 208-277 Vac Coil Voltage Input: 208-277 Vac ; 50-60 Hz Drop Out = 60 Vac Pull In = 160 Vac 30 AMP TRACK MOUNT CONTROL RELAY RIBM043PN 4.00 Track Mount Relay 30 Amp 3PDT with 480 Vac Coil N/C Made in USA Meets "Buy American" of ARRA 2009 N/O Comm N/C Comm Not Used 480 Vac N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 2.450 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase 42 Functional Devices, Inc. | American Made. American Owned. Coil Current: 140 mA @ 480 Vac Coil Voltage Input: 480 Vac/dc ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac Notes: · See model RIBM043PN-HD for use in more transient prone environments RELAYS 30 AMP TRACK MOUNT CONTROL RELAY RIBM043PN-HD 4.00 Track Mount Relay 30 Amp 3PDT with 480 Vac Coil (-HD for More Transient Prone Environments) N/C N/O Comm N/C Comm Not Used 480 Vac N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 3.250 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916, UL864 C-UL, California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 30 Amp General Use @ 300 Vac 30 Amp Resistive @ 28 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240-277 Vac, 1 Phase 1 HP @ 120 Vac, 1 Phase Heavy Pilot Duty @ 600 Vac 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1110 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase Coil Current: 140 mA @ 480 Vac Coil Voltage Input: 480 Vac/dc ; 50-60 Hz Drop Out = 140 Vac Pull In = 340 Vac (800) 888-5538 | www.functionaldevices.com 43 RELAYS LATCHING RELAYS Enclosed Features · Prepackaged for convenience · Electromechanical relay · Mechanically latching · Status output contact · Electronic ballast rating · 20 Amp rating 24 Vac Supply Controller On Common O Latch Unlatch N/O Momentary Wall Switch Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Local Power 120-277 Vac Lighting Status to Controller N/O Momentary Wall Switch ENCLOSED LATCHING RELAYS COIL VOLTAGE MODEL # RIBL12B · RIBL12BM · RIBL12SB · RIBL12SBM · RIBL24B · RIBL24BM · RIBL24SB · RIBL24SBM · AC/DC 12 12 12 12 24 24 24 24 RELAYS 1 1 1 1 1 1 1 1 CONTACTS SPST SPST SPST SPST SPST SPST SPST SPST OVERRIDE SWITCH · · AUXILIARY OUTPUT · · · · · · NOTES = UL Listed : UL60947 Low-Voltage Switchgear and Controlgear SPEC PAGE 45 45 45 45 46 46 46 46 44 Functional Devices, Inc. | American Made. American Owned. RELAYS LATCHING RELAYS RIBL12B Enclosed Mechanically Latching Relay 20 Amp SPST with 12 Vac/dc Coil RIBL12BM Enclosed Mechanically Latching Relay 20 Amp SPST with 12 Vac/dc Coil, Status LED and Auxiliary Output Made in USA Meets "Buy American" of ARRA 2009 Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Wht/Red 12 Vac/dc () UNLATCH Org Line Org Load Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Wht/Red 12 Vac/dc () UNLATCH SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary Contact Closed: LED On = Voltage Detected on Load Wire (RIBL12BM) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple (RIBL12B) 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIBL12BM) Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Yel Line Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry RIBL12B-RD · Red housing RIBL12B-N4 · NEMA 4X housing (Not available on switched models) Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 182 mA @ 10 Vac 20 Amp Ballast @ 120-277 Vac 250 mA @ 12 Vac 16 Amp Electronic Ballast @ 120-277 Vac 165 mA @ 10 Vdc 5540 Watt Tungsten @ 277 Vac 198 mA @ 12 Vdc 20 Amp Tungsten @ 277 Vac 250 mA @ 15 Vdc 720 VA Pilot Duty @ 120-277 Vac 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 10 Vdc / 11 Vac Auxiliary Contact: 3 Amp @ 30 Vac/dc max. Notes: · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL12BM) LATCHING RELAYS RIBL12SB Enclosed Mechanically Latching Relay 20 Amp SPST + Override with 12 Vac/dc Coil Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Org Line * Wht/Red 12 Vac/dc () UNLATCH Org Load * Mechanically latches and unlatches with a coil input or by manual override RIBL12SBM Enclosed Mechanically Latching Relay 20 Amp SPST + Override with 12 Vac/dc Coil, Status LED and Auxiliary Output Wht/Blu 12 Vac/dc () LATCH Wht/Yel 12 Vac/dc (+) Wht/Red 12 Vac/dc () UNLATCH * Mechanically latches and unlatches with a coil input or by manual override Yel Line * Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay, Dual Coil Contact Ratings: Coil Current: Expected Relay Life: 1 million cycles minimum mechanical 20 Amp Resistive @ 120-277 Vac 182 mA @ 10 Vac Operating Temperature: -30 to 140° F 20 Amp Ballast @ 120-277 Vac 250 mA @ 12 Vac Humidity Range: 5 to 95% (noncondensing) 16 Amp Electronic Ballast @ 120-277 Vac 165 mA @ 10 Vdc Operate Time: 50ms 5540 Watt Tungsten @ 277 Vac 198 mA @ 12 Vdc Maximum Pulse Length: 30 seconds 20 Amp Tungsten @ 277 Vac 250 mA @ 15 Vdc Relay Status / Auxiliary Contact Closed: LED On = Voltage Detected on Load Wire (RIBL12SBM) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple (RIBL12SB) 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIBL12SBM) Wires: 16, 600V Rated 720 VA Pilot Duty @ 120-277 Vac 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Latch / Unlatch: Min. 10 Vdc / 11 Vac Auxiliary Contact: 3 Amp @ 30 Vac/dc max. Approvals: UL Listed, UL60947, C-UL, CE, RoHS Notes: Housing Rating: UL Accepted for Use in Plenum, NEMA 1 · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. Gold Flash: No · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. Override Switch: Yes · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL12SBM) (800) 888-5538 | www.functionaldevices.com 45 RELAYS LATCHING RELAYS RIBL24B Enclosed Mechanically Latching Relay 20 Amp SPST with 24 Vac/dc Coil RIBL24BM Enclosed Mechanically Latching Relay 20 Amp SPST with 24 Vac/dc Coil, Status LED and Auxiliary Output Made in USA Meets "Buy American" of ARRA 2009 Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Wht/Red 24 Vac/dc () UNLATCH Org Line Org Load Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Wht/Red 24 Vac/dc () UNLATCH SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary Contact Closed: LED On = Voltage Detected on Load Wire (RIBL24BM) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple (RIBL24B) 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIBL24BM) Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Yel Line Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry RIBL24B-RD · Red housing RIBL24B-N4 · NEMA 4X housing (Not available on switched models) Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 175 mA @ 20 Vac 20 Amp Ballast @ 120-277 Vac 210 mA @ 24 Vac 16 Amp Electronic Ballast @ 120-277 Vac 92 mA @ 20 Vdc 5540 Watt Tungsten @ 277 Vac 110 mA @ 24 Vdc 20 Amp Tungsten @ 277 Vac 138 mA @ 30 Vdc 720 VA Pilot Duty @ 120-277 Vac 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Notes: Latch / Unlatch: Min. 20 Vdc / 22 Vac Auxiliary Contact: 3 Amp @ 30 Vac/dc max. · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL24BM) LATCHING RELAYS RIBL24SB Enclosed Mechanically Latching Relay 20 Amp SPST + Override with 24 Vac/dc Coil Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Org Line * Wht/Red 24 Vac/dc () UNLATCH Org Load * Mechanically latches and unlatches with a coil input or by manual override RIBL24SBM Enclosed Mechanically Latching Relay 20 Amp SPST + Override with 24 Vac/dc Coil, Status LED and Auxiliary Output Wht/Blu 24 Vac/dc () LATCH Wht/Yel 24 Vac/dc (+) Wht/Red 24 Vac/dc () UNLATCH * Mechanically latches and unlatches with a coil input or by manual override Yel Line * Org Load Wht/Blk Load Neutral Gry AUXILIARY CONTACT Gry Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Latching Relay Dual Coil Expected Relay Life: 1 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 50ms Maximum Pulse Length: 30 seconds Relay Status / Auxiliary Contact Closed: LED On = Voltage Detected on Load Wire (RIBL24SBM) Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple (RIBL24SB) 2.30 x 3.20 x 1.80 with .50 NPT Nipple (RIBL24SBM) Wires: 16, 600V Rated Approvals: UL Listed, UL60947, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes 46 Functional Devices, Inc. | Contact Ratings: Coil Current: 20 Amp Resistive @ 120-277 Vac 175 mA @ 20 Vac 20 Amp Ballast @ 120-277 Vac 210 mA @ 24 Vac 16 Amp Electronic Ballast @ 120-277 Vac 92 mA @ 20 Vdc 5540 Watt Tungsten @ 277 Vac 110 mA @ 24 Vdc 20 Amp Tungsten @ 277 Vac 138 mA @ 30 Vdc 720 VA Pilot Duty @ 120-277 Vac 2 HP @ 277 Vac 3 HP @ 240 Vac 1.5 HP @ 120 Vac Notes: Latch / Unlatch: Min. 20 Vdc / 22 Vac Auxiliary Contact: 3 Amp @ 30 Vac/dc max. · Application of voltage on latch coil (Wht/Blu & Wht/Yel) will close the contact. · Application of voltage on unlatch coil (Wht/Red & Wht/Yel) will open the contact. · Auxiliary contact and status LED activate when 120-277 Vac is applied between Load (Org) wire and Load Neutral (Wht/Blk) wire. (RIBL24SBM) American Made. American Owned. RELAYS LOW-INPUT / OPTOISOLATED RELAYS Enclosed | Track Mount Prepackaged Like the Original RIB® with Special Features · Extremely low current draw on the input · Control input can connect to AO for relay control · Protect controller from feedback or voltage transients Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Controller High Voltage 60 Hz ac Controller Low Voltage 60 Hz ac Digital Out (or Analog Out) Power Supply Relay Opto Input Opto RIB® Load 24 Vac/dc Analog or Digital Out Power Supply Relay Opto Input Opto RIB® Load · Optoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from analog outputs. ENCLOSED LOW-INPUT / OPTOISOLATED RELAYS MODEL # RIBTELC CONTROL INPUT · 5-25 Vac/dc RIBTELS · 5-25 Vac/dc RIBTE24B · 5-25 Vac/dc RIBTE01B · 5-25 Vac/dc RIBTE02B · 5-25 Vac/dc RIBTE24SB · 5-25 Vac/dc RIBTE01SB · 5-25 Vac/dc RIBTE02SB · 5-25 Vac/dc RIBTE24P · 5-25 Vac/dc RIBTE01P · 5-25 Vac/dc RIBTE02P · 5-25 Vac/dc RIBTE01P-S · 5-25 Vac/dc RIBTE02P-S · 5-25 Vac/dc POWER INPUT 10-30 Vac/dc 10-30 Vac/dc 24 Vac/dc 120 Vac 208-277 Vac 24 Vac/dc 120 Vac 208-277 Vac 24 Vac/dc 120 Vac 208-277 Vac 120 Vac 208-277 Vac RELAYS 1 1 1 1 1 1 1 1 1 1 1 1 1 CONTACTS SPDT SPST SPDT SPDT SPDT SPST SPST SPST DPDT DPDT DPDT DPDT DPDT OVERRIDE SWITCH 1 1 1 1 1 1 NOTES SPEC PAGE 48 48 48 49 49 50 50 51 51 52 52 53 53 TRACK MOUNT LOW-INPUT / OPTOISOLATED RELAYS MODEL # RIBME2401B CONTROL INPUT · 5-25 Vac/dc RIBME2402B · 5-25 Vac/dc RIBME2401SB · 5-25 Vac/dc RIBME2402SB · 5-25 Vac/dc RIBME2401P · 5-25 Vac/dc RIBME2402P · 5-25 Vac/dc POWER INPUT 24 Vac/dc/120 Vac 24 Vac/dc/208-277 Vac 24 Vac/dc/120 Vac 24 Vac/dc/208-277 Vac 24 Vac/dc/120 Vac 24 Vac/dc/208-277 Vac RELAYS 1 1 1 1 1 1 CONTACTS SPDT SPDT SPST SPST DPST DPST = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada OVERRIDE SWITCH 1 1 NOTES SPEC PAGE 53 53 54 54 54 54 (800) 888-5538 | www.functionaldevices.com 47 RELAYS LOW COIL INPUT RELAYS RIBTELC Enclosed Relay Hi/Low Separation 10 Amp SPDT, 10-30 Vac/dc Power Input + 5-25 Vac/dc Control Input RIBTELS Enclosed Relay Hi/Low Separation 10 Amp SPST + Override, 10-30 Vac/dc Power Input + 5-25 Vac/dc Control Input Made in USA Meets "Buy American" of ARRA 2009 5-25 Vac/dc CONTROL INPUT 10-30 Vac/dc POWER INPUT Blu - N/C Yel - Comm Org - N/O 5-25 Vac/dc CONTROL INPUT 10-30 Vac/dc POWER INPUT Selectable Jumper Wire Org CLOSED Org OPEN AUTO SPECIFICATIONS Power Input: 10-30 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes (RIBTELC), No (RIBTELS) Override Switch: No (RIBTELC), Yes (RIBTELS) Contact Ratings: 10 Amp Resistive @ 120-277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 Watt Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 1/3 HP @ 120-240 Vac (N/O) 1/6 HP @ 120-240 Vac (N/C) 1/4 HP @ 277 Vac (N/O) 1/8 HP @ 277 Vac (N/C) Power Input Ratings: 33 mA @ 10 Vac 35 mA @ 12 Vac 46 mA @ 24 Vac 55 mA @ 30 Vac 13 mA @ 10 Vdc 15 mA @ 12 Vdc 18 mA @ 24 Vdc 20 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Normally Open or Normally Closed selected by yellow jumper wire (RIBTELS) LOW COIL INPUT RELAY RIBTE24B Enclosed Relay Hi/Low Separation 20 Amp SPDT, 24 Vac/dc Power Input + 5-25 Vac/dc Control Input 24 Vac/dc POWER INPUT Blu - N/C Yel - Comm 5-25 Vac/dc CONTROL INPUT Org - N/O SPECIFICATIONS Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) 48 Functional Devices, Inc. | American Made. American Owned. LOW COIL INPUT RELAY RIBTE01B Enclosed Relay Hi/Low Separation 20 Amp SPDT, 120 Vac Power Input + 5-25 Vac/dc Control Input RELAYS 5-25 Vac/dc CONTROL INPUT Wht/Blk 120 Vac POWER INPUT Wht/Blk Blu - N/C Yel - Comm Org - N/O SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: Power Input Ratings: 20 Amp Resistive @ 277 Vac 47 mA @ 120 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) LOW COIL INPUT RELAY RIBTE02B Enclosed Relay Hi/Low Separation 20 Amp SPDT, 208-277 Vac Power Input + 5-25 Vac/dc Control Input 5-25 Vac/dc CONTROL INPUT Wht/Brn 208-277 Vac POWER INPUT Wht/Brn Blu - N/C Yel - Comm Org - N/O SPECIFICATIONS Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: Power Input Ratings: 20 Amp Resistive @ 277 Vac 69 mA @ 208-277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Made in USA Meets "Buy American" of ARRA 2009 Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) 49 LOW COIL INPUT RELAY RIBTE24SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override, 24 Vac/dc Power Input + 5-25 Vac/dc Control Input 24 Vac/dc POWER INPUT Selectable Jumper Wire Org RELAYS 5-25 Vac/dc CONTROL INPUT CLOSED Org OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 50 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Normally Open or Normally Closed selected by yellow jumper wire LOW COIL INPUT RELAY RIBTE01SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override, 120 Vac Power Input + 5-25 Vac/dc Control Input Wht/Blk 120 Vac POWER INPUT Wht/Blk 5-25 Vac/dc CONTROL INPUT Selectable Jumper Wire Org CLOSED Org OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Power Input Ratings: 47 mA @ 120 Vac Notes: · Normally Open or Normally Closed selected by yellow jumper wire 50 Functional Devices, Inc. | American Made. American Owned. RELAYS LOW COIL INPUT RELAY RIBTE02SB Enclosed Relay Hi/Low Separation 20 Amp SPST + Override, 208-277 Vac Power Input + 5-25 Vac/dc Control Input Wht/Brn 208-277 Vac POWER INPUT Wht/Brn 5-25 Vac/dc CONTROL INPUT Selectable Jumper Wire Org CLOSED Org OPEN AUTO SPECIFICATIONS Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes LOW COIL INPUT RELAY RIBTE24P Enclosed Relay Hi/Low Separation 20 Amp DPDT, 24 Vac/dc Power Input + 5-25 Vac/dc Control Input Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 69 mA @ 208-277 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Normally Open or Normally Closed selected by yellow jumper wire 24 Vac/dc POWER INPUT 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O SPECIFICATIONS Power Input: 24 Vac/dc, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Power Input Ratings: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc Made in USA Meets "Buy American" of ARRA 2009 Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) (800) 888-5538 | www.functionaldevices.com 51 RELAYS LOW COIL INPUT RELAY RIBTE01P Enclosed Relay Hi/Low Separation 20 Amp DPDT, 120 Vac Power Input + 5-25 Vac/dc Control Input Wht/Blk 120 Vac POWER INPUT Wht/Blk 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) LOW COIL INPUT RELAY RIBTE02P Enclosed Relay Hi/Low Separation 20 Amp DPDT, 208-277 Vac Power Input + 5-25 Vac/dc Control Input Wht/Brn 208-277 Vac POWER INPUT Wht/Brn 5-25 Vac/dc CONTROL INPUT Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O SPECIFICATIONS Power Input: 208-277 Vac, 50-60 Hz Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 208-277 Vac 52 Functional Devices, Inc. | American Made. American Owned. Made in USA Meets "Buy American" of ARRA 2009 Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) RELAYS LOW COIL INPUT RELAYS RIBTE01P-S Enclosed Relay Hi/Low Separation 20 Amp DPDT +Override, 120 Vac Power Input + 5-25 Vac/dc Control Input Wht/Blk 120 Vac POWER INPUT COIL ON COIL OFF AUTO Wht/Blk Blu - N/C Yel - Comm Org - N/O Gry - N/C 5-25 Vac/dc CONTROL INPUT Prp - Comm Brn - N/O RIBTE02P-S Enclosed Relay Hi/Low Separation 20 Amp DPDT +Override, 208-277 Vac Power Input + 5-25 Vac/dc Control Input Wht/Brn 208-277 Vac POWER INPUT COIL ON COIL OFF AUTO Wht/Brn Blu - N/C Yel - Comm Org - N/O Gry - N/C 5-25 Vac/dc CONTROL INPUT Prp - Comm Brn - N/O SPECIFICATIONS Power Input: 120 Vac, 50-60 Hz (RIBTE01P-S) 208-277 Vac, 50-60 Hz (RIBTE02P-S) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: Yes* Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac Made in USA Meets "Buy American" of ARRA 2009 Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) Notes: · Override capability is made possible by supplying constant voltage on the Power Input. No Control Input Voltage is necessary to override the relay. * Power Input Ratings: 105 mA @ 120 Vac (RIBTE01P-S) 105 mA @ 208-277 Vac (RIBTE02P-S) LOW COIL INPUT TRACK MOUNT RELAYS RIBME2401B 4.00 Track Mount Relay 20 Amp SPDT, 24 Vac/dc/120 Vac Power Input + 5-25 Vac/dc Control Input RIBME2402B 4.00 Track Mount Relay 20 Amp SPDT, 24 Vac/dc/208-277 Vac Power Input + 5-25 Vac/dc Control Input 5-25 Vac/dc CONTROL INPUT Comm Comm N/O 5-25 Vac/dc CONTROL INPUT Comm Comm N/O 24 Vac/dc N/C POWER INPUTS 120 Vac 24 Vac/dc N/C POWER INPUTS 208-277 Vac Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 24 Vac/dc/120 Vac, 50-60 Hz (RIBME2401B) 24 Vac/dc/208-277 Vac, 50-60 Hz (RIBME2402B) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.050 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac (800) 888-5538 | www.functionaldevices.com Power Input Ratings: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBME2401B) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBME2402B) Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) 53 RELAYS LOW COIL INPUT TRACK MOUNT RELAYS RIBME2401SB 4.00 Track Mount Relay 20 Amp SPST + Override, 24 Vac/dc/120 Vac Power Input + 5-25 Vac/dc Control Input RIBME2402SB 4.00 Track Mount Relay 20 Amp SPST + Override, 24 Vac/dc/208-277 Vac Power Input + 5-25 Vac/dc Control Input 5-25 Vac/dc CONTROL INPUT 5-25 Vac/dc CONTROL INPUT Comm Selectable Jumper Wire Comm Selectable Jumper Wire 24 Vac/dc POWER INPUTS 120 Vac CLOSED OPEN AUTO Not Used 24 Vac/dc POWER INPUTS 208-277 Vac CLOSED OPEN AUTO Not Used Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 24 Vac/dc/120 Vac, 50-60 Hz (RIBME2401SB) 24 Vac/dc/208-277 Vac, 50-60 Hz (RIBME2402SB) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.550 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Control Input Ratings: .4 mA @ 5 Vdc 2 mA @ 24 Vdc .9 mA @ 10 Vdc 3 mA @ 24 Vac 1 mA @ 12 Vdc (Non Polarized) Power Input Ratings: 50 mA @ 18 Vac 33 mA @ 22 Vdc 83 mA @ 24 Vac 35 mA @ 24 Vdc 47 mA @ 120 Vac (RIBME2401SB) 47 mA @ 30 Vdc 69 mA @ 208-277 Vac (RIBME2402SB) Notes: · Normally Open or Normally Closed selected by yellow jumper wire LOW COIL INPUT TRACK MOUNT RELAYS RIBME2401P 4.00 Track Mount Relay 20 Amp DPST, 24 Vac/dc/120 Vac Power Input + 5-25 Vac/dc Control Input RIBME2402P 4.00 Track Mount Relay 20 Amp DPST, 24 Vac/dc/208-277 Vac Power Input + 5-25 Vac/dc Control Input 5-25 Vac/dc CONTROL INPUT 5-25 Vac/dc CONTROL INPUT Comm 24 Vac/dc POWER INPUTS 120 Vac N/O Comm N/O Comm Comm 24 Vac/dc POWER INPUTS 208-277 Vac N/O Comm N/O Comm Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Power Input: 24 Vac/dc/120 Vac, 50-60 Hz (RIBME2401P) 24 Vac/dc/208-277 Vac, 50-60 Hz (RIBME2402P) Control Input: 5-25 Vac/dc, 50-60 Hz # Relays & Contact Type: One (1) DPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 3.100 x 4.000 x 2.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: Yes Override Switch: No 54 Functional Devices, Inc. Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc, 15 Vdc 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 15 Amp Resistive @ 600 Vac 770 VA Pilot Duty @ 120 Vac 1158 VA Pilot Duty @ 240 Vac 1110 VA Pilot Duty @ 277 Vac 1640 VA Pilot Duty @ 480 Vac 3 HP @ 480-600 Vac 2 HP @ 240-277 Vac 1 HP @ 120 Vac | American Made. American Owned. Power Input Ratings: 138 mA @ 24 Vac 105 mA @ 120 Vac (RIBME2401P) 105 mA @ 208-277 Vac (RIBME2402P) 77 mA @ 30 Vdc Control Input Ratings: .4 mA @ 5 Vdc .9 mA @ 10 Vdc 1 mA @ 12 Vdc 2 mA @ 24 Vdc 3 mA @ 24 Vac (Non Polarized) RELAYS POLARIZED RELAYS Enclosed | Track Mount Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Same Great Prepackaging · Relays are polarized to work in a supervised system and may be turned on and off by reversing polarity. For fire alarm systems, smoke control systems, etc. Fire Alarm Systems Application · Coil input is polarity sensitive · For use with fire alarm systems · System supervision for controllers that utilize end-of-line resistors · Four wire circuit ensures indication of broken wiring connection with RIB® Load Load RIB24C-FA Coil + RIB24C-FA Coil + Controller Signaling Circuit End of Line Resistor ENCLOSED ALARM RELAYS MODEL # RIB12C-FA RIB24C-FA RIB12S-FA RIB24S-FA RIBT24B-FA RIB24P-FA COIL VOLTAGE · 12 Vac/dc · 24 Vac/dc · 12 Vac/dc · 24 Vac/dc · 24 Vac/dc · 24 Vac/dc RELAYS 1 1 1 1 1 1 CONTACTS SPDT SPDT SPST SPST SPDT DPDT OVERRIDE SWITCH 1 1 NOTES SPEC PAGE 56 56 56 56 57 57 TRACK MOUNT ALARM RELAYS MODEL # COIL VOLTAGE RIBMN12C-FA · 12 Vac/dc RIBMN24C-FA · 24 Vac/dc RIBMN12S-FA · 12 Vac/dc RIBMN24S-FA · 24 Vac/dc RELAYS 1 1 1 1 = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada CONTACTS SPDT SPDT SPST SPST OVERRIDE SWITCH 1 1 NOTES SPEC PAGE 58 58 58 58 (800) 888-5538 | www.functionaldevices.com 55 RELAYS FIRE ALARM RELAYS RIB12C-FA Enclosed Relay 10 Amp, Polarized with 12 Vac/dc Coil 2nd Wht/Blu 12 Vac/dc Wht/Blu + Blu 12 Vac/dc N/C RIB12S-FA Enclosed Relay 10 Amp + Override, Polarized with 12 Vac/dc Coil 2nd Wht/Blu 12 Vac/dc Wht/Blu + 12 Vac/dc Org Made in USA Meets "Buy American" of ARRA 2009 Wht/Yel Comm 2nd Wht/Yel Comm Yel Comm Org N/O Wht/Yel Comm 2nd Wht/Yel Comm CLOSED Org OPEN AUTO SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIB12C-FA) Yes (RIB12S-FA) Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac RIB12C-FA-RD RIB12S-FA-RD · Red housing RIB12C-FA-N4 · NEMA 4X housing, UL508 only Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 36 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number (RIB12S-FA) FIRE ALARM RELAYS RIB24C-FA Enclosed Relay 10 Amp, Polarized with 24 Vac/dc Coil 2nd Wht/Blu 24 Vac/dc Wht/Blu + Blu 24 Vac/dc N/C RIB24S-FA Enclosed Relay 10 Amp + Override, Polarized with 24 Vac/dc Coil 2nd Wht/Blu 24 Vac/dc Wht/Blu + 24 Vac/dc Org Made in USA Meets "Buy American" of ARRA 2009 Wht/Yel Comm 2nd Wht/Yel Comm Yel Comm Org N/O Wht/Yel Comm 2nd Wht/Yel Comm CLOSED Org OPEN AUTO RIB24C-FA-RD RIB24S-FA-RD · Red housing RIB24C-FA-N4 · NEMA 4X housing, UL508 only SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No (RIB24C-FA) Yes (RIB24S-FA) Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc Notes: · Order Normally Closed by adding "-NC" to end of model number (RIB24S-FA) 56 Functional Devices, Inc. | American Made. American Owned. RELAYS FIRE ALARM RELAY RIBT24B-FA Enclosed Relay Hi/Low Separation 20 Amp SPDT, Polarized with 24 Vac/dc Coil Comm 24 Vac/dc + Blu N/C Yel Comm Org N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Made in USA Meets "Buy American" of ARRA 2009 Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 47 mA @ 18 Vac 83 mA @ 24 Vac 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc FIRE ALARM RELAY RIB24P-FA Enclosed Relay 20 Amp DPDT, Polarized with 24 Vac/dc Coil 2nd Wht/Blu 24 Vac/dc Wht/Blu + 24 Vac/dc Wht/Yel Comm 2nd Wht/Yel Comm Blu - N/C Yel - Comm Org - N/O Gry - N/C Prp - Comm Brn - N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 20 Amp Resistive @ 300 Vac 20 Amp Resistive @ 28 Vdc, 15 Vdc 15 Amp Resistive @ 600 Vac 1 HP @ 120 Vac 2 HP @ 240-277 Vac 3 HP @ 480 Vac - 600 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA Pilot Duty @ 120 Vac 1,158 VA Pilot Duty @ 240 Vac 1,110 VA Pilot Duty @ 277 Vac 1,640 VA Pilot Duty @ 480 Vac Coil Current: 110 mA @ 20 Vac 138 mA @ 24 Vac 55 mA @ 20 Vdc 55 mA @ 24 Vdc 77 mA @ 30 Vdc (800) 888-5538 | www.functionaldevices.com Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 3 Vac / 3.8 Vdc Pull In = 20 Vac / 20 Vdc 57 RELAYS FIRE ALARM TRACK MOUNT RELAYS RIBMN12C-FA 2.75 Track Mount Relay 15 Amp, Polarized with 12 Vac/dc Coil RIBMN12S-FA 2.75 Track Mount Relay 15 Amp + Override, Polarized with 12 Vac/dc Coil 12 Vac/dc + Comm N/C Comm N/O 12 Vac/dc + Comm AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.100 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN12C-FA) Yes (RIBMN12S-FA) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Made in USA Meets "Buy American" of ARRA 2009 Cut for N/O Cut for N/C Coil Current: 53 mA @ 10 Vac 62 mA @ 12 Vac 29 mA @ 11 Vdc 35 mA @ 12 Vdc Coil Voltage Input: 12 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN12S-FA) FIRE ALARM TRACK MOUNT RELAYS RIBMN24C-FA 2.75 Track Mount Relay 15 Amp, Polarized with 24 Vac/dc Coil RIBMN24S-FA 2.75 Track Mount Relay 15 Amp + Override, Polarized with 24 Vac/dc Coil Comm 24 Vac/dc N/C Comm N/O 24 Vac/dc + Comm AUTO OPEN CLOSED Comm N/O or N/C Selectable Jumpers (must cut one only) SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 6ms Relay Status: LED On = Activated Dimensions: 1.100 x 2.750 x 1.750 Track Mount: 2.750, See MT212 Series on page 152 MT212 Mounting Track Sold Separately Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS Gold Flash: No Override Switch: No (RIBMN24C-FA) Yes (RIBMN24S-FA) Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Made in USA Meets "Buy American" of ARRA 2009 Cut for N/O Cut for N/C Coil Current: 26 mA @ 20 Vac 31 mA @ 24 Vac 48 mA @ 35 Vac 14 mA @ 20 Vdc 18 mA @ 24 Vdc 28 mA @ 35 Vdc Coil Voltage Input: 24 Vac/dc ; 50-60 Hz Drop Out = 2 Vac / 2.5 Vdc Pull In = 9 Vac / 11 Vdc Notes: · Must cut appropriate jumper to select Normally Open or Normally Closed (RIBMN24S-FA) 58 Functional Devices, Inc. | American Made. American Owned. DRY CONTACT INPUT RELAYS Enclosed | Track Mount Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). The Dry Contact Input RIB® Series offers all the advantages of the standard RIB® line plus it can be activated by a wide range of dry contacts such as thermostats, current switches, other relays, solid-state switches, etc. The Dry Contact Input RIB® accepts local power to provide the low-voltage (Class 2) power needed to activate the relay; just close the dry contact input. The power to energize the relay can be brought to the relay on a separate pair of wires along with the control output of a controller, or can be a local power source near the relay. The relay contacts are isolated from the input power and the dry contact input; thus, the relay contacts can be wired to switch any other power-load or low-voltage load (see specifications for contact ratings.) One model can be used for many installations (model RIB21CDC can be powered from any voltage from 120 Vac to 277 Vac; see specifications for the input power of other models.) RELAYS Can be activated by dry contacts such as thermostats, current switches, etc. · Self-powered current switches of the RIBX Series and relays of the Dry Contact Input RIB® Series may be applied to interlock Load 2 to Load 1. Current sensing may be internal or external Wire Being Monitored Load 1 RIBX Series Current Sensor Only (Class 2) Current Sensor Status Local Power 120, 208, 240, 277 Vac Dry Contact Input RIB® Series Load 2 ENCLOSED DRY CONTACT INPUT RELAYS MODEL # RIB21CDC · RIB01BDC · RIB02BDC · RIB01SBDC · RIB02SBDC · RIB01SBCDC · RIB02SBCDC · RIBD01BDC · RIBD02BDC · RIBD01BDC-DOB · RIBD02BDC-DOB · POWER INPUT 120-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac 120 Vac 208-277 Vac RELAYS 1 1 1 1 1 1 1 1 1 1 1 CONTACTS SPDT SPDT SPDT SPST SPST SPDT SPDT SPDT SPDT SPDT SPDT OVERRIDE SWITCH 1 1 2 2 NOTES # # # # SPEC PAGE 60 60 60 61 61 61 61 62 62 63 63 TRACK MOUNT DRY CONTACT INPUT RELAYS MODEL # RIBM01ZNDC · RIBM02ZNDC · RIBM013PNDC · POWER INPUT 120 Vac 208-277 Vac 120 Vac RELAYS 1 1 1 CONTACTS DPDT DPDT 3PDT OVERRIDE SWITCH = UL Listed : UL916 Energy Management; USA & Canada = UL Component Recognized : UL916 Energy Management; USA & Canada # = Time Delay (800) 888-5538 | www.functionaldevices.com NOTES SPEC PAGE 64 64 64 59 RELAYS DRY CONTACT INPUT RELAYS RIB21CDC Enclosed Relay 10 Amp SPDT, Class 2 Dry Contact Input, 120-277 Vac Power Input Blk 120 - 277 Vac Red Neutral or Other Phase CONTROL CIRCUIT Dry Contact Input Wht/Blu Wht/Red Org N/O Yel Comm Blu N/C SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 1.70 x 2.80 x 1.50 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Made in USA Meets "Buy American" of ARRA 2009 RIB21CDC-RD · Red housing RIB21CDC-N4 · NEMA 4X housing, UL508 only Power Input: 50 mA @ 240 Vac Max. Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. DRY CONTACT INPUT RELAYS RIB01BDC Enclosed Relay 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input RIB02BDC Enclosed Relay 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input Blk 120 Vac Wht Neutral CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Blk 208-277 Vac Red Neutral or Other Phase CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL California State Fire Marshal, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIB01BDC) 62 mA @ 208-277 Vac (RIB02BDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. 60 Functional Devices, Inc. | American Made. American Owned. RELAYS DRY CONTACT INPUT RELAYS RIB01SBDC Enclosed Relay 20 Amp SPST-N/O + Override, Class 2 Dry Contact Input, 120 Vac Power Input RIB02SBDC Enclosed Relay 20 Amp SPST-N/O + Override, Class 2 Dry Contact Input, 208-277 Vac Power Input Blk 120 Vac Wht Neutral CONTROL CIRCUIT CLOSED OPEN AUTO Org Org Dry Contact Input Wht/Red Wht/Blu Blk 208-277 Vac Red Neutral or Other Phase CONTROL CIRCUIT CLOSED OPEN AUTO Org Org Dry Contact Input Wht/Red Wht/Blu Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 240 Watt Tungsten @ 120 Vac (N/C) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIB01SBDC) 62 mA @ 208-277 Vac (RIB02SBDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. · Order Normally Closed by adding "-NC" to end of model number DRY CONTACT INPUT RELAYS RIB01SBCDC Enclosed Relay 20 Amp SPDT + Override, Class 2 Dry Contact Input, 120 Vac Power Input RIB02SBCDC Enclosed Relay 20 Amp SPDT + Override, Class 2 Dry Contact Input, 208-277 Vac Power Input Blk 120 Vac Wht Neutral CONTROL CIRCUIT Blk 208-277 Vac Red Neutral or Other Phase CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Dry Contact Input Wht/Red Wht/Blu MANUAL AUTO OPEN N/C N/O CLOSED CLOSED Yel Comm Blu N/C Org N/O Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 1.8 Seconds Relay Status: LED On = Activated Dimensions: 2.30 x 3.20 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIB01SBCDC) 62 mA @ 208-277 Vac (RIB02SBCDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to activate relay. If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. (800) 888-5538 | www.functionaldevices.com 61 RELAYS DRY CONTACT INPUT TIME DELAY RELAYS RIBD01BDC Enclosed Delay on Make Relay 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input RIBD02BDC Enclosed Delay on Make Relay 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input Wht/Blk 120 Vac Wht/Blk Neutral CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Wht/Brn 208-277 Vac Wht/Brn CONTROL Neutral or Other Phase CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms after time delay Relay Status: Red LED On = Activated Time Delay Status: Pink LED FLASHING = Timing / Relay Deactivated Timing Mode: Delay On Make Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIBD01BDC) 62 mA @ 208-277 Vac (RIBD02BDC) Notes: · Dry Contact Input Operation: Close White/Red wire to White/Blue wire to start timing. Relay will activate after timing sequence has ended. · If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. Range Selection 1234 Timing Adjustment C BD AE Only Close 1 Switch Depressed for closed Depressed for open TIMING TABLE Switch Ranges Close Dip Switch A Potentiometer Setting B C D 6s-20s 1 6s 9s 13s 16s 22s-1min15s 2 22s 36s 50s 1min4s 1min30s-5min 3 1min30s 2min10s 3min20s 4min16s 6min-20min 4 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min Dry Contact Input 1. Common Time Delay Operation (Dry contact from N/C pushbutton, for example.) Load on N/C Contact Load on N/O Contact (Not as commonly used but absolutely may be used) Time Delay 2. Extended Dry Contact Closure with Time Delay Operation (Dry contact from grocery door operating air curtain, for example, or any contact that is closed when door is open.) 3. Repeated Dry Contact Openings within Time Delay Setting (Keeps load on until dry contact openings cease.) Closed Open Time Delay On Time Delay Time Delay O (Retriggered) LED Status: · Pink LED ashes while Time Delay is in progress. · Red LED is o when N/C is closed. · Red LED is on when N/O is closed. Typical N/C Contact Wiring BLU Line YEL Switched Leg On O 62 Functional Devices, Inc. | American Made. American Owned. RELAYS DRY CONTACT INPUT TIME DELAY RELAYS RIBD01BDC-DOB Enclosed Delay on Break Relay 20 Amp SPDT, Class 2 Dry Contact Input, 120 Vac Power Input RIBD02BDC-DOB Enclosed Delay on Break Relay 20 Amp SPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input Wht/Blk 120 Vac Wht/Blk Neutral CONTROL CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Wht/Brn 208-277 Vac Wht/Brn CONTROL Neutral or Other Phase CIRCUIT Dry Contact Input Wht/Red Wht/Blu Org N/O Yel Comm Blu N/C Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms after time delay Relay Status: Red LED On = Activated Time Delay Status: Pink LED FLASHING = Timing / Relay Deactivated Timing Mode: Delay On Break Timing Range: 6 seconds - 20 minutes Timing Adjustment: 4 position DIP switch for range selection and single turn potentiometer for timing adjustment within range Timing Tolerance: Switches 1& 2 = +10% Switches 3 & 4 = +5% Timing Repeatability: +1% Temperature Timing Variance: +1% Voltage Timing Variance: +1% Recycle Time: 750ms Maximum Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL, CE, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 42 mA @ 120 Vac (RIBD01BDC-DOB) 62 mA @ 208-277 Vac (RIBD02BDC-DOB) Notes: · Dry Contact Input Operation: Open White/Red wire and White/Blue wire to start timing. Relay will activate after timing sequence has ended. · If more than one dry contact RIB® shares a single dry contact input, White/Blue must be common. Range Selection 1234 Timing Adjustment C BD AE Only Close 1 Switch Depressed for closed Depressed for open TIMING TABLE Switch Ranges Close Dip Switch A Potentiometer Setting B C D 6s-20s 1 6s 9s 13s 16s 22s-1min15s 2 22s 36s 50s 1min4s 1min30s-5min 3 1min30s 2min10s 3min20s 4min16s 6min-20min 4 6min 9min 13min20s 17min20s E 20s 1min15s 5min 20min 1. Common Time Delay Operation (Dry contact from N/O pushbutton, for example.) Dry Contact Input Load on N/C Contact Load on N/O Contact (Not as commonly used but absolutely may be used) Time Delay 2. Extended Dry Contact Closure with Time Delay Operation (Dry contact from grocery door operating air curtain, for example, or any contact that is closed when door is open.) Time Delay 3. Repeated Dry Contact Closures within Time Delay Setting (Keeps load on until dry contact closures cease.) Closed Open On Time Delay Time Delay O (Retriggered) LED Status: · Pink LED ashes while Time Delay is in progress. · Red LED is o when N/C is closed. · Red LED is on when N/O is closed. Typical N/C Contact Wiring BLU Line YEL Switched Leg On O (800) 888-5538 | www.functionaldevices.com 63 DRY CONTACT INPUT TRACK MOUNT RELAYS RIBM01ZNDC 4.00 Track Mount Relay 30 Amp DPDT, Class 2 Dry Contact Input, 120 Vac Power Input RIBM02ZNDC 4.00 Track Mount Relay 30 Amp DPDT, Class 2 Dry Contact Input, 208-277 Vac Power Input Dry Contact Input CONTROL CIRCUIT POWER INPUT 120 Vac Neutral N/C N/O Comm N/C N/O Comm Dry Contact Input CONTROL CIRCUIT POWER INPUT 208-277 Vac Neutral or Other Phase N/C N/O Comm N/C N/O Comm Made in USA Meets "Buy American" of ARRA 2009 RELAYS SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Relay Status: Red LED On = Activated Power Status: Green LED On = Activated Dimensions: 2.875 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: Yes Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 25 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 3 HP @ 480-600 Vac 2 HP @ 240/277 Vac 1 HP @ 120 Vac 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast 770 VA @ 120 Vac 1158 VA @ 240 Vac 1109 VA @ 277 Vac 1640 VA @ 480 Vac NEMA B600 Pilot Duty Power Input: 95 mA @ 120 Vac (RIBM01ZNDC) 95 mA @ 208-277 Vac (RIBM02ZNDC) Notes: · Dry Contact Input Operation: Close dry contact to activate relay. DRY CONTACT INPUT TRACK MOUNT RELAYS RIBM013PNDC 4.00 Track Mount Relay 30 Amp 3PDT, Class 2 Dry Contact Input, 120 Vac Power Input N/C Made in USA Meets "Buy American" of ARRA 2009 DRY CONTACT INPUT CONTROL CIRCUIT POWER INPUT 120 Vac Neutral N/O Comm N/C N/O Comm N/C N/O Comm SPECIFICATIONS # Relays & Contact Type: One (1) 3PDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: Red LED On = Activated Power Status: Green LED On = Activated Dimensions: 2.875 x 4.000 x 1.750 Track Mount: 4.000, See MT4 Series on page 152 MT4 Mounting Track Sold Separately Approvals: UL Component Recognized, UL916 C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 30 Amp Resistive @ 300 Vac 30 Amp Resistive @ 28 Vdc 15 Amp Resistive @ 600 Vac 7.5 HP @ 480 Vac, 3 Phase 5 HP @ 240 Vac, 3 Phase 3 HP @ 480-600 Vac, 1 Phase 2 HP @ 240/277 Vac, 1 Phase 1 HP @ 120 Vac, 1Phase 20 Amp Ballast @ 277-480 Vac Not rated for Electronic Ballast Heavy Pilot Duty 770 VA @ 120 Vac, 1 Phase 1158 VA @ 240 Vac, 1 Phase 1109 VA @ 277 Vac, 1 Phase 1640 VA @ 480 Vac, 1 Phase 1466 VA @ 240 Vac, 3 Phase 2122 VA @ 480 Vac, 3 Phase 64 Functional Devices, Inc. | American Made. American Owned. Power Input: 95 mA @ 120 Vac Notes: · Dry Contact Input Operation: Close dry contact to activate relay. NETWORK COMPATIBLE RELAYS LonMark® | BACnet® | Wi-Fi | Modbus® Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). Use These Devices When a More Expensive Multi-Output Controller is Too Much for the Job · UL Listed · LonWorks®,BACnet®, Wi-Fi, and Modbus® protocol · Analog input · Analog output · Binary output · Binary input · Thermistor inputs available · On-board current sensors available · Panel mount · Enclosed versions · NEMA 4X available RELAYS LONMARK® DEVICES MODEL # RIBTW2401B-LN · RIBTW2402B-LN · RIBTW2401SB-LN · RIBTW2402SB-LN · RIBMNWX2401SB-LN · RIBTWX2401SB-LN · RIBMNWX2402SB-LN · RIBTWX2402SB-LN · RIBMW24SB-LNAI · RIBTW24SB-LNAI · RIBMW24SB-LNT2 · RIBTW24SB-LNT2 · RIBMW24SB-LNT3 · RIBTW24SB-LNT3 · RELAY OUTPUT 1 1 1 1 1 1 1 1 1 1 1 1 1 1 DRY CONTACT BINARY INPUT 1 1 1 1 1 1 1 1 1 1 ANALOG INTERNAL CURRENT PRECON® INPUT SENSOR FEEDBACK THERMISTOR INPUT · · · · 1 1 10k Type 2 10k Type 2 10k Type 3 10k Type 3 DEVICE POWER AC/DC 24 24 24 24 24 24 24 24 24 24 24 24 24 24 AC 120 208-277 120 208-277 120 120 208-277 208-277 CONTACTS SPDT SPDT SPST SPST SPST SPST SPST SPST SPST SPST SPST SPST SPST SPST OVERRIDE SWITCH NOTES SPEC PAGE 66 66 1 67 1 67 1 68 1 68 1 69 1 69 1 70 1 70 1 71 1 71 1 71 1 71 BACNET® DEVICES DRY CONTACT RELAY BINARY ANALOG ANALOG MODEL # OUTPUT INPUT INPUT OUTPUT RIBTW2401B-BC · 1 1 RIBTW2402B-BC · 1 1 RIBMNWX2401B-BC · 1 1 RIBTWX2401B-BC · 1 1 RIBMNWX2402B-BC · 1 1 RIBTWX2402B-BC · 1 1 RIBMNW24B-BCAI · 1 2 1 RIBTW24B-BCAI · 1 2 1 RIBTW24B-BCAO · 1 2 1 1 RIBMNWD12-BCDI 12 RIBMNWD12-BC 12 RIBMW24B-44-BC · 4 4 ACCUMULATOR INPUT 2 INTERNAL CURRENT SENSOR FEEDBACK · · · · PRECON® THERMISTOR INPUT 10k Type 2 or 3 10k Type 2 or 3 10k Type 2 or 3 DEVICE POWER AC/DC AC 24 120 24 208-277 24 120 24 120 24 208-277 24 208-277 24 24 24 24 24 24 CONTACTS SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT OVERRIDE SWITCH NOTES # # # # # # # # # NEW # SPEC PAGE 72 72 73 73 74 74 75 75 76 77 78 79 WI-FI DEVICES MODEL # RIBTW24B-WI-N4 · · RIBTW2401B-WIUI-N4 RELAY OUTPUT 1 1 DRY CONTACT BINARY INPUT 1 1 UNIVERSAL INPUT 2 DEVICE POWER AC/DC AC 24 24 120 CONTACTS SPDT SPDT OVERRIDE SWITCH # # NOTES NEW NEW SPEC PAGE 80 81 MODBUS® DEVICES MODEL # RIBMNW24B-MBAI · RIBTW24B-MBAI · RELAY OUTPUT 1 1 DRY CONTACT BINARY INPUT 2 2 ANALOG INPUT 1 1 INTERNAL CURRENT SENSOR FEEDBACK PRECON® THERMISTOR INPUT 10k Type 2 10k Type 2 DEVICE POWER AC/DC AC 24 24 CONTACTS SPDT SPDT OVERRIDE SWITCH # # NOTES SPEC PAGE 82 82 = UL Listed : UL916 Energy Management, USA & Canada Precon® is a registered trademark of Kele and Associates. # = Coil Side Relay Override (requires unit to be powered) (800) 888-5538 | www.functionaldevices.com 65 NETWORK COMPATIBLE RELAYS RIBTW2401B-LN LonWorks® Twisted-Pair FT-10 Network Enclosed Dual I/O Device: One Binary Output (20 Amp Relay SPDT), One Binary Input (Dry Contact Class 2); 24 Vac/dc or 120 Vac Power Input RIBTW2402B-LN LonWorks® Twisted-Pair FT-10 Network Enclosed Dual I/O Device: One Binary Output (20 Amp Relay SPDT), One Binary Input (Dry Contact Class 2); 24 Vac/dc or 208-277 Vac Power Input Service Button Service Button RELAYS 24 Vac/dc Com LON LON PINK LED = Binary Input Status GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service 24 Vac/dc Com LON LON PINK LED = Binary Input Status GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service Class 2 Dry Contact Binary Input Class 2 Dry Contact Binary Input Made in USA Meets "Buy American" of ARRA 2009 Wht/Yel Wht/Blk Blu Yel Org Neutral 120 Vac N/C Comm N/O Wht/Yel Wht/Brn Blu Yel Org Neutral or 208-277 Vac N/C Comm N/O Other Phase SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Pink LED: Binary Input Status Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: No Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 20 Amp Ballast @ 277 Vac (N/C) 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 111 mA @ 24 Vac 96 mA @ 120 Vac (RIBTW2401B-LN) 105 mA @ 208-277 Vac (RIBTW2402B-LN) 81 mA @ 24 Vdc Power Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTW2401B-LN) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTW2402B-LN) Notes: · Order with P1 option by adding "-P1" to end of model number. The P1 option is pre-programmed to allow dry contact binary input to command the relay. Contact closure on the BI will activate relay. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Transceiver Compatibility: FT3120 / FT3150, FTT-10 / FTT-10A, and LPT-10 / LPT-11 Tranceivers Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. RIBTW2401B-LN or RIBTW2402B-LN Half-Wave Device DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer Status of Binary Input Invert status of Binary Input Max time between updates Min time between updates SNVT NAME nvi Value nvo Value Fb NondcieDOebfajeucltt nci Max Receive T nvo Value NV1 nvi Requesnt ci InveNrtV2 nvo Status nci Max Send T nci Min Send T SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_switch SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm 24 Vac 24 Vac/dc Com The relay will go to the default state when the cColomsemduLnoicoaptiAoncttuimateorr times out. Setting the timer value 24 Vac Com to zerNoowdiellOcabujesectthe communication to never time(Boinuatr.y Output) IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Iwt oisrkreacfotemrmpoewndeer dlotsos.pItuitsathvealrueespinonnsciibMilNiatVxy1Soef nnthvdieVTaultusoeeer ntosuernesNtuhVr2ee RnvIBo Vraelu-seyFnbchronizes itself on the netthis value does not cause conflicts in NV1 nnvei Rtewqouerskt but may traffic.N(NV2o vnavlouSeta=tuNs o "heartbeat" cause many traffic collisions; High updates / no re-sychronization; value = Fenwci uDpefdaaulttes but many Low Value = Many less collisions.) updates nci Max Receive T 66 Node Object NV1 nvi Request NV2 nvo Status Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb nci Default nci Max Receive T Open Loop Sensor Object (Binary Input) NV1 nvo Value nci Invert nci Max Send T nci Min Send T Closed Loop Actuator (Binary Output) Open Loop Sensor Object (Binary Input) NV1 nvi Value Functional Devices, Inc. | American Made. American Owned. NV2 nvo Value Fb NV1 nvo Value nci Default nci Invert NETWORK COMPATIBLE RELAYS RIBTW2401SB-LN LonWorks® Twisted-Pair FT-10 Network Enclosed Dual I/O Device: One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); 24 Vac/dc or 120 Vac Power Input RIBTW2402SB-LN LonWorks® Twisted-Pair FT-10 Network Enclosed Dual I/O Device: One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); 24 Vac/dc or 208-277 Vac Power Input Service Button Service Button 24 Vac/dc Com LON LON PINK LED = Binary Input Status GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service 24 Vac/dc Com LON LON PINK LED = Binary Input Status GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service RELAYS Class 2 Dry Contact Binary Input Wht/Yel Wht/Blk Neutral 120 Vac CLOSED OPEN AUTO Selectable Jumper Wire Org Org Class 2 Dry Contact Binary Input CLOSED OPEN AUTO Selectable Wht/Yel Jumper Wire Neutral or Wht/Brn Other Phase 208-277 Vac Org Org Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Pink LED: Binary Input Status Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 111 mA @ 24 Vac 96 mA @ 120 Vac (RIBTW2401SB-LN) 105 mA @ 208-277 Vac (RIBTW2402SB-LN) 81 mA @ 24 Vdc Power Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIBTW2401SB-LN) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIBTW2402SB-LN) Notes: · Order with P1 option by adding "-P1" to end of model number. The P1 option is pre-programmed to allow dry contact binary input to command the relay. Contact closure on the BI will activate relay. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Transceiver Compatibility: FT3120 / FT3150, FTT-10 / FTT-10A, and LPT-10 / LPT-11 Tranceivers Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer SNVT NAME nvi Value Nnovdoe VOablujeecFtb nci Default nci Max Receive T SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm Status of Binary Input Invert status of Binary Input NV1 nvi Requestnvo ValNuVe2 nvo Status nci Invert SNVT_switch SNVT_lev_disc Max time between updates nci Max Send T SNVT_elapsed_tm RIBTW2401SB-LN or RIBTW2402SB-LN Half-Wave Device Min time between updates nci Min Send T SNVT_elapsed_tm Closed Loop Actuator 24 Vac 24 Vac/dc Com 24 Vac TtohezerNreooladwyeiwllOiclblajgueoscettothtehecodmefmauulnt isctaattieonwthoennetvheerctoimme(mBionuuanrty.icOautitopunt)timer times out. Setting the timer value Com It is recommended to put a value in nci MNVa1x nvi Value Send T to ensureNtVh2enRvoIBVarelu-esFybnchronizes itself on the net- IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection NV1 nvwnieRoterwqkuoaersfkttetrrapfofiwcN.e(VNr2loosnvsva.olIuStteiast=utshNeor"ehsepaorntbsiebailti"tyupodf tahteesu/snneciroDtroeefa-esunyltscuhrreonthizisatviaolnu;eLdooweVsanluoet cause conflicts in = Many updates between devices. Band on diode faces towards RIB(s). but may cause many traffic collisions; High value =ncFi eMwaxuRpedceaivteesTbut many less collisions.) Node Object NV1 nvi Request NV2 nvo Status Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb nci Default nci Max Receive T Open Loop Sensor Object (Binary Input) NV1 nvo Value nci Invert nci Max Send T nci Min Send T Closed Loop Actuator (Binary Output) Open Loop Sensor Object (Binary Input) (800) 888-5538 | www.functionaldevices.com NV1 nvi Value NV2 nvo Value Fb NV1 nvo Value nci Invert 67 RELAYS GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service PINK LED = Current Flow NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMNWX2401SB-LN 2.75 Track Mount LonWorks® Twisted-Pair FT-10 Network Dual I/O Device; One Binary Output (20 Amp Relay SPST + Override); One Binary Input (Current Sensor 0.25 - 20 Amp, Relay Load Sensing), 24 Vac/dc or 120 Vac Power Input RIBTWX2401SB-LN Enclosed LonWorks® Twisted-Pair FT-10 Network Dual I/O Device; One Binary Output (20 Amp Relay SPST + Override); One Binary Input (Current Sensor 0.25 - 20 Amp, Relay Load Sensing), 24 Vac/dc or 120 Vac Power Input LON Service Button LON Open Loop Sensor Object * Internal Current Sensor Selectable Jumper Wire Com 24 Vac/dc Com 120 Vac CLOSED OPEN AUTO Not used Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Dimensions: 6.00 x 2.75 x 1.75 (RIBMNWX2401SB-LN) 7.00 x 4.28 x 2.00 with .75 NPT Nipple (RIBTWX2401SB-LN) Track Mount: MT212-6 Mounting Track Provided Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Override Switch: Yes Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. RIBMNWX2401SB-LN or RIBTWX2401SB-LN Half-Wave Device Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 105 mA @ 120 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. Notes: · Normally Open or Normally Closed selected by yellow jumper wire. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2401SB-LN-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2401SB-LN-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2401SB-LN-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer Status of Binary Input Invert status of Binary Input Max time between updates Min time between updates SNVT NAME nvi Value NondveoOVbajleucetFb nci Default nci Max Receive T NV1 nvi Request nvo Value NV2 nvo Status nci Invert nci Max Send T nci Min Send T SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_switch SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm 24 Vac 24 Vac/dc Com Closed Loop Actuator 24 Vac TtohezerNreooladwyeiwllOiclblajgueoscettothtehecodmefmauulnt isctaattieonwthoennetvheerctoimm(Beminoauurnyt.iOcuattpiount) timer times out. Setting the timer value Com It is recommended to put a value in nciNMVa1x Snevni VdalTueto ensurNeVt2henvRoIVBalruee-Fsbynchronizes itself on the net- IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection NV1 nvwnieRoterwqkuoaersfkttetrrapfofiwcN.e(VNr2loosnvsva.olIutSteiast=utshNeor"ehsepaorntbsiebailti"tyupodf tahteesun/scnei Droetrofeau-eslntyscuhrreonthizisatviaolnu;eLdooweVsanluoet cause conflicts in = Many updates between devices. Band on diode faces towards RIB(s). but may cause many traffic collisions; High valuen=ciFMeawx RuepcdeiaveteTs but many less collisions.) 68 Node Object NV1 nvi Request NV2 nvo Status Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb nci Default nci Max Receive T * Open Loop Sensor Object (Binary Input) NV1 nvo Value nci Invert nci Max Send T nci Min Send T Closed Loop Actuator (Binary Output) * Open Loop Sensor Object (Binary Input) NV1 nvi Value NV2 FnvuonVacluteioFbnal Devices, Inc. | AmNeVr1icannvoMValuaede. American Owned. nci Default nci Max Receive T nci Invert nci Max Send T GREEN LED = Network Status RED LED = Relay Activated YELLOW LED = Service PINK LED = Current Flow RELAYS NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMNWX2402SB-LN 2.75 Track Mount LonWorks® Twisted-Pair FT-10 Network Dual I/O Device; One Binary Output (20 Amp Relay SPST + Override); One Binary Input (Current Sensor 0.25 - 20 Amp, Relay Load Sensing), 24 Vac/dc or 208-277 Vac Power Input RIBTWX2402SB-LN Enclosed LonWorks® Twisted-Pair FT-10 Network Dual I/O Device; One Binary Output (20 Amp Relay SPST + Override); One Binary Input (Current Sensor 0.25 - 20 Amp, Relay Load Sensing), 24 Vac/dc or 208-277 Vac Power Input LON LON Com 24 Vac/dc Com 208-277 Vac Service Button Open Loop Sensor Object * Internal Current Sensor Selectable Jumper Wire CLOSED OPEN AUTO Not used Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Dimensions: 6.00 x 2.75 x 1.75 (RIBMNWX2402SB-LN) 7.00 x 4.28 x 2.00 with .75 NPT Nipple (RIBTWX2402SB-LN) Track Mount: MT212-6 Mounting Track Provided Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Override Switch: Yes Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 120 mA @ 208-277 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. Notes: · Normally Open or Normally Closed selected by yellow jumper wire. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2402SB-LN-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2402SB-LN-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2402SB-LN-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off SNVT NAME nvi Value Node ObnjevcotValue Fb nci Default SNVT TYPE SNVT_switch SNVT_switch SNVT_switch Communication timer Status of Binary Input nci Max Receive T NV1 nvi Request NnVv2o VnavlouSetatus SNVT_elapsed_tm SNVT_switch Invert status of Binary Input nci Invert SNVT_lev_disc Max time between updates nci Max Send T SNVT_elapsed_tm RIBMNWX2402SB-LN or RIBTWX2402SB-LN Half-Wave Device Min time between updates nci Min Send T SNVT_elapsed_tm Closed Loop Actuator 24 Vac 24 Vac/dc Com 24 Vac NoThdee rOeblajyecwtill go to the default state when t(hBeincaroymOmutpuunti)cation timer times out. Setting the timer value to zero will cause the communication to never time out. Com It is recommended to put a valueNinV1ncinMvi aVaxluSeend T toNeVn2snuvroeVtahluee Fb RIB re-synchronizes itself on the net- ^^ Option 2: IN4004 NV1 Add diode on 24 Vac power (Com) interconnection nvi Requewnsteotrwk oarfkteNtrrVap2fofiwncv.eo(NrSltooatsvussa. lIut eis=thNeor"ehsepaorntbsiebailti"tyupondfctai hDteeesfua/usnletrotroe-esnyscuhrreonthizisatviaolnu;eLdooweVsanluoet cause conflicts in = Many updates between devices. Band on diode faces towards RIB(s). but may cause many traffic collisions; HighnvciaMluaex =ReFceeiwveuTpdates but many less collisions.) Node Object NV1 nvi Request NV2 nvo Status Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb nci Default nci Max Receive T * Open Loop Sensor Object (Binary Input) NV1 nvo Value nci Invert nci Max Send T nci Min Send T Closed Loop Actuator (Binary Output) NV1 nvi Value NV2 nvo Value Fb * Open Loop Sensor Object (Binary Input) (800) 888-5538 | www.functionaldevices.com NV1 nvo Value 69 NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMW24SB-LNAI 4.00 Track Mount LonWorks® Twisted-Pair FT-10 Network Three I/O Device; One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); One Analog Input (0-5Vdc / 0-10 Vdc); 24 Vac/dc Power Input RIBTW24SB-LNAI Enclosed LonWorks® Twisted-Pair FT-10 Network Enclosed Three I/O Device; One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); One Analog Input (0-5Vdc / 0-10 Vdc); 24 Vac/dc Power Input. + 5V (typically not used) AI Com Analog-In 1 2 OPEN Class 2 Dry Contact Binary Input + 5V (typically not used) AI Com Analog-In 1 2 OPEN RELAYS Class 2 Dry Contact Binary Input Service Button YELLOW LED = Service PINK LED = Binary Input Status RED LED = Relay Activated GREEN LED = Network Status 5 V 10 V CLOSED OPEN AUTO Service Button YELLOW LED = Service PINK LED = Binary Input Status RED LED = Relay Activated GREEN LED = Network Status 5 V 10 V CLOSED OPEN AUTO Made in USA Meets "Buy American" of ARRA 2009 LON LON 24 Vac/dc Com LON LON 24 Vac/dc Com Selectable Jumper Wire Selectable Jumper Wire SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Pink LED: Binary Input Status Dimensions: 4.00 x 4.00 x 1.50 (RIBMW24SB-LNAI) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTW24SB-LNAI) Track Mount: MT4-4 Mounting Track Provided Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Override Switch: Yes Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Transceiver Compatibility: FT3120 / FT3150, FTT-10 / FTT-10A, and LPT-10 / LPT-11 Tranceivers Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object 0520 Analog Input Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. Closed Loop Actuator (BinaNryoOduetpOubt)ject OpeCnloLsoeodpLoSoenpsAocrtOuabtjoecr t ((BBiinnaarryy IOnputupt)ut) vo Status NV1 nvi Value NV2 nvo Value Fb NV1 nvi Request NV2 nvo Status nci Default nci Max Receive T NV1 nvi Value NNVV12 nnvvooVVaalulueeFb nci Invert nci nMcai xDSeefanudltT nnccii MMainx SReencedivTe T or OpeCnloLsoeodpLSoeonpsAorctOubajteocrt Open Loop Sensor Object t (B(BininaarryyInOpuutpt)ut) Analo(BginIanrpy uIntput) o Value Fb V2 nvo Status NV1 nvi Value NVN1V2 nnvvoo VVaalluuee Fb nci Invert nci MncaixDSeefnaudlTt nnccii MMianxSReencdeiTve T NV1 nvo NV1 AnnavloogValue nci MaxnSceinIndvTe1rt nci MninciSMenadx STe1nd T nci Mncini MDienltSaend T Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 111 mA @ 24 Vac 81 mA @ 24 Vdc Power Input: 24 Vac/dc ; 50-60 Hz * Notes: · Order with P1 option by adding "-P1" to end of model number. The P1 option is pre-programmed to allow dry contact binary input to command the relay. Contact closure on the BI will activate relay. · Normally Open or Normally Closed selected by yellow jumper wire. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24SB-LNAI-N4) · Close DIP switch 1 for 0-5 Vdc Analog Input. Close DIP switch 2 for 0-10 Vdc Analog Input. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ · See page 71 for -LNT2 or -LNT3 models if using a thermistor. If using a thermistor on the Analog Input, set DIP switches to the 0-5 Vdc setting. A look-up table must also be made. DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer Status of Binary Input Invert sOtapteunsLoofoBpinSaernysoInrpOubtject Max timeAbneatlw(oBgieneaInrnypuIunpptudta) tes Min time between updates Value of Analog-In NV1NVn1vo AnnvaoloVgalue Max time nbcei MtwaxenSeceinnIndAvTen1rat log updates Min time bnceitMwnicnei SeMenanxdASTne1nadloTg updates nci nMciinMDienltSaend T Min change in Analog before updates SNVT NAME nvi Value nvo Value Fb nci Default nci Max Receive T nvo Value nci Invert AnalongcIinMpuatx Send T nci Min Send T nvoNVA1nanvloo gAnalog nci ManxcSieMndaTx1 Send T1 nci MinnSceinMd iTn1 Send T1 nci MinnDceilMta in Delta SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_switch SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm SNVT_lev_percent SNVT_elapsed_tm SNVT_elapsed_tm SNVT_lev_percent The relay will go to the default state when the communication timer times out. Setting the timer value to zero will cAanuasloegtIhnepuctommunication to never time out. Iwt oisrkreacfotemrmpoewndeer dlotsoNsV.p1ItuintsvoatAhvneaalolrugeespinonnsciibMiliatxy Send T to ensure the of the user to ensure RIB re-synchronizes itself on the netthis value does not cause conflicts in network trafnnficccii MM. (ianNxSSoeennvddaTT11lue = No "heartbeat" updates / no re-sychronization; Low Value = Many updates but may causnecimMinanDeyltatraffic collisions; High value = Few updates but many less collisions.) 0-5Vdc or 0-10 Vdc Temperature, Humidity, Pressure Transducer 70 AI AI Com Analog 10K Input 24 Vac RIBMW24SB-LNAI or RIBTW24SB-LNAI 24 Vac/dc Com Half-Wave Device 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Functional Devices, Inc. | American Made. American Owned. RELAYS NETWORK COMPATIBLE RELAYS RIBMW24SB-LNT2 4.00 Track Mount LonWorks® Twisted-Pair FT-10 Network Three I/O Device; One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); Precon® Type 2 Thermistor Input; 24 Vac/dc Power Input Connect Precon® 10K @ 77 (25), Type 2, Model 24 (or equivalent) to Thermistor terminals: +5 Vdc and Analog-In. Set DIP switch to 5V (see below.) RIBTW24SB-LNT2 Enclosed LonWorks® Twisted-Pair FT-10 Network Three I/O Device; One Binary Output (20 Amp Relay SPST + Override), One Binary Input (Dry Contact, Class 2); Precon® Type 2 Thermistor Input; 24 Vac/dc Power Input Connect Precon® 10K @ 77 (25), Type 2, Model 24 (or equivalent) to Thermistor terminals: +5 Vdc and Analog-In. Set DIP switch to 5V (see below.) Class 2 Dry Contact Binary Input + 5V AI Com (typically not used) Analog-In 1 2 OPEN Class 2 Dry Contact Binary Input + 5V AI Com (typically not used) Analog-In 1 2 OPEN LON LON 24 Vac/dc Com LON LON 24 Vac/dc Com Service Button YELLOW LED = Service PINK LED = Binary Input Status RED LED = Relay Activated GREEN LED = Network Status 5 V 10 V CLOSED OPEN AUTO Selectable Jumper Wire Service Button YELLOW LED = Service PINK LED = Binary Input Status RED LED = Relay Activated GREEN LED = Network Status 5 V 10 V CLOSED OPEN AUTO Selectable Jumper Wire Made in USA Meets "Buy American" of ARRA 2009 THERMISTOR INPUT SPECIFICATIONS # Relays & Contact Type: One (1) SPST Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Status Red LED: Relay Status Yellow LED: Service Status Pink LED: Binary Input Status Dimensions: 4.00 x 4.00 x 1.50 (RIBMW24SB-LNT2) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTW24SB-LNT2) Track Mount: MT4-4 Mounting Track Provided Approvals: FCC, LonMark®, CE, RoHS UL Listed, UL916, C-UL Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Override Switch: Yes Channel: TP/FT-10 Transceiver Type: FT5000 Smart Transceiver Transceiver Compatibility: FT3120 / FT3150, FTT-10 / FTT-10A, and LPT-10 / LPT-11 Tranceivers Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object 1040 Temperature Sensor Downloadable Files: PDF, XIF, APB, VSS and NXE available on website. 24 Vac RIBMW24SB-LNT2, RIBTW24SB-LNT2, RIBMW24SB-LNT3 or RIBTW24SB-LNT3 24 Vac/dc Com Half-Wave Device 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac (N/O) 10 Amp Ballast @ 120/277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 111 mA @ 24 Vac 81 mA @ 24 Vdc Power Input: 24 Vac/dc ; 50/60 Hz ^ Notes: · Order with P1 option by adding "-P1" to end of model number. The P1 option is pre-programmed to allow dry contact binary input to command the relay. Contact closure on the BI will activate relay. · Normally Open or Normally Closed selected by yellow jumper wire. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24SB-LNT2-N4) · -35 to 100°C range in one degree steps. -36°C indicates below range, 101°C indicates above range. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ · Can be used with Precon® Type 3 Thermistor Input. Use suffix "-LNT3" instead of "LNT2" when ordering. Thermistor not included. DESCRIPTION Command to open/close relay Command status of relay Default state of relay on/off Communication timer Status of Digital-In Invert status of Digital-In Max time between updates Min time between updates T2 Thermistor input * Max time between Temperature updates Min time between Temperature updates Min change in Temperature before updates SNVT NAME nvi Value nvo Value Fb nci Default nci Max Receive T nvo Value nci Invert nci Max Send T nci Min Send T nvo HVACTemp nci Max Send T1 nci Min Send T1 nci Min Delta SNVT TYPE SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_switch SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm SNVT_temp_p SNVT_elapsed_tm SNVT_elapsed_tm SNVT_temp_p The relay will go to the default state when the communication timer times out. Setting the timer value to zero will cause the communication to never time out. It is recommended to put a value in nci Max Send T to ensure the RIB re-synchronizes itself on the network after power loss. It is the responsibility of the user to ensure this value does not cause conflicts in network traffic. (No value = No "heartbeat" updates / no re-sychronization; Low Value = Many updates but may cause many traffic collisions; High value = Few updates but many less collisions.) Object NV2 nvo Status Closed Loop Actuator N(oBidnearOy ObujetpcutNt)ode Object ClOospeednLLooooppCASlcoetsnuesadotroLOroobpjeActctuator (Binar(yBiOnuartypNuInto)p(dBuietn)aOrybOjeuctpt ut) Open LooCploSOseenpdseonLroLOoopbojpAecSteunastor Object * Te(mBinpaeryraI(ntBupinuraet)ryS(eOBniunstaporuyrtI)nput) Open Loop Sensor Object * Temperatur*eT(SeBeimnnapsryeoIrnaptuutr)e Sensor NV1 nvi Value NV2 nvo Value Fb NV1 NV1 nvi RequesNt V1 nvi RNeVq2uesntvo StatusNV2 nvo Status nci Default nci Max Receive T nvi ValueNV1 nvNi VVa2luNneVvo1 ValnuveoFNVbaVlu2envo Value Fb NV1 nvni RcieIqnuveesrtt NV2 nvo Status ncinDcieMfaauxltSendnTci Default nci ManxcRi MecienivSeennTcidMTax Receive T NV1 nvi ValueNNV1V1 nnvvoNoHVVVa2AluCneNTveoVmV1paluenvFobValue ncnicMi IanxveSretndT1 nci Invert nncicMi MaixnSSeennndcdiTDTn1ecfiaMulatx Send T ncni MciiMnniSnceiDnMdealTtxanRceicMeiivneSTend T NV1 nvo HVANCVTe1NmVp1nvnovoVHalVuAeCTemp nci Max SendT1nnccii IMnvaexrStendT1 nci Min SendnTc1inMciaMx iSneSnednTd T1 nci Min Delntaci Mncini MSeinndDeTlta (800) 888-5538 | www.functionaldevices.com * Temperature Sensor NV1 nvo HVACTemp nci Max SendT1 nci Min Send T1 nci Min Delta 71 RELAYS Dry Contact Binary Input REF A() B(+) MSB LSB Baud Rate Relay Override Dry Contact Binary Input REF A() B(+) MSB LSB Baud Rate Relay Override NETWORK COMPATIBLE RELAYS RIBTW2401B-BC Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); One Binary Input (Dry Contact, Class 2); 24 Vac/dc or 120 Vac Power Input, Optional End of Line Resistor (EOL) Included. RIBTW2402B-BC Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); One Binary Input (Dry Contact, Class 2); 24 Vac/dc or 208-277 Vac Power Input, Optional End of Line Resistor (EOL) Included. } } } } MSTP 0 1 1 2 3 4 5 6 7 8 9 10 11 12 24 Vac/dc Common MS/TP ADDRESS Connect Jumper for EOL. Disconnect for no terminating resistor. MSTP 0 1 1 2 3 4 5 6 7 8 9 10 11 12 24 Vac/dc Common MS/TP ADDRESS Connect Jumper for EOL. Disconnect for no terminating resistor. Made in USA Meets "Buy American" of ARRA 2009 Wht/Yel Wht/Blk Blu Yel Org Neutral 120 Vac N/C Comm N/O Wht/Yel Wht/Brn Blu Yel Org Neutral 208-277 Vac N/C Comm N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Green LED: Network Communication Red LED: Relay Status Dimensions: 4.00 x 4.00 x 1.80 with .50 NPT Nipple Wires: 16, 600V Rated Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac 96 mA @ 120 Vac (RIBTW2401B-BC) 121 mA @ 208-277 Vac (RIBTW2402B-BC) Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz (RIBTW2401B-BC) 24 Vac/dc ; 208-277 Vac ; 50/60 Hz (RIBTW2402B-BC) Notes: · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. http://www.functionaldevices.com/pdf/ pics/RIBTW240xB-BC_PICS.pdf Or scan QR code with your smart phone. DIP SWITCHES* BAUD RATE DIP SWITCHES* RELAY STATE** 8 9 10 11 12 0 0 0 9600 1 0 Auto 0 0 1 19200 X 1 Override on 0 1 0 38400 0 0 Override off 0 1 1 57600 * 0 = Open ; 1 = Closed 1 0 0 76800 ** Device must be powered for override 1 0 1 115200 All other combinations=9600 baud · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBTW2401B-BC or RIBTW2402B-BC Half-Wave Device 24 Vac 24 Vac/dc Com 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). 72 Functional Devices, Inc. | American Made. American Owned. NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMNWX2401B-BC 2.75 Track Mount BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (One Current Sensor 0.25 - 20 Amp, Relay Load Sensing & One Dry Contact Binary Input), 24 Vac/dc or 120 Vac Power Input, Optional End of Line Resistor (EOL) Included. RIBTWX2401B-BC Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (One Current Sensor 0.25 - 20 Amp, Relay Load Sensing & One Dry Contact Binary Input), 24 Vac/dc or 120 Vac Power Input, Optional End of Line Resistor (EOL) Included. } 1 2 3 4 5 6 7 8 9 10 11 12 1 0 Relay Override Baud Rate LSB MSB MS/TP ADDRESS Dry Contact Binary Input } } A() MSTP B(+) REF Red LED=Relay Status Green LED=Network Communication Pink LED=Current Sensor Status Pink LED=Binary Input Status Internal Current Sensor Contacts COM N/O N/C High Voltage } Power Input Low Voltage } Power Input Connect Jumper for EOL. Disconnect for no terminating resistor. Made in USA Meets "Buy American" of ARRA 2009 RELAYS Neutral 120 Vac 24 Vac/dc Comm SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00 x 2.75 x 1.75 (RIBMNWX2401B-BC) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTWX2401B-BC) Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 24 Vac/dc ; 120 Vac ; 50/60 Hz Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 105 mA @ 120 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 All other combinations=9600 baud BAUD RATE 9600 19200 38400 57600 76800 115200 DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBMNWX2401B-BC or RIBTWX2401B-BC Half-Wave Device Notes: · Device can be powered by either 24 Vac/dc or 120 Vac, but not both. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2401B-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2401B-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2401B-BC-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. http://www.functionaldevices.com/pdf/pics/ RIBxWX240xB-BC_PICS.pdf Or scan QR code with your smart phone. 24 Vac 24 Vac/dc Com 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). (800) 888-5538 | www.functionaldevices.com 73 NETWORK COMPATIBLE RELAY / CURRENT SENSOR COMBOS RIBMNWX2402B-BC 2.75 Track Mount BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (One Current Sensor 0.25 - 20 Amp, Relay Load Sensing & One Dry Contact Binary Input), 24 Vac/dc or 208-277 Vac Power Input, Optional End of Line Resistor (EOL) Included. RIBTWX2402B-BC Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (One Current Sensor 0.25 - 20 Amp, Relay Load Sensing & One Dry Contact Binary Input), 24 Vac/dc or 208-277 Vac Power Input, Optional End of Line Resistor (EOL) Included. } 1 2 3 4 5 6 7 8 9 10 11 12 1 0 Relay Override Baud Rate LSB MSB MS/TP ADDRESS Dry Contact Binary Input } } A() MSTP B(+) REF Red LED=Relay Status Green LED=Network Communication Pink LED=Current Sensor Status Pink LED=Binary Input Status Internal Current Sensor Contacts COM N/O N/C High Voltage } Power Input Low Voltage } Power Input Connect Jumper for EOL. Disconnect for no terminating resistor. Made in USA Meets "Buy American" of ARRA 2009 RELAYS Neutral 208-277 Vac 24 Vac/dc Comm SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00 x 2.75 x 1.75 (RIBMNWX2402B-BC) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTWX2402B-BC) Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input: 24 Vac/dc ; 208-277 Vac ; 50/60 Hz Power Input Ratings: 105 mA @ 24 Vac 78 mA @ 24 Vdc 120 mA @ 208-277 Vac Current Sensor Range: 0.25 - 20 Amps Threshold fixed at .25 Amps. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 All other combinations=9600 baud BAUD RATE 9600 19200 38400 57600 76800 115200 DIP SWITCHES* RELAY STATE** 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. RIBMNWX2402B-BC or RIBTWX2402B-BC Half-Wave Device Notes: · Device can be powered by either 24 Vac/dc or 208-277 Vac, but not both. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTWX2402B-BC-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTWX2402B-BC-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTWX2402B-BC-N4-GY) · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Internal current sensor input) · Device Instance changed via Object Identifier Property of Device Object · PIC Statement available on website. http://www.functionaldevices.com/pdf/pics/ RIBxWX240xB-BC_PICS.pdf Or scan QR code with your smart phone. 74 24 Vac 24 Vac/dc Com 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Functional Devices, Inc. | American Made. American Owned. NETWORK COMPATIBLE RELAYS RIBMNW24B-BCAI 2.75" Track Mount BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2/T3 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. RIBTW24B-BCAI Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2/T3 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. Made in USA Meets "Buy American" of ARRA 2009 RELAYS Green LED=Network Status Red LED=Relay Status Pink LED=BI 1 Status Pink LED=BI 2 Status BI 1 COM BI 1 BI 2 COM BI 2 5 V 10 V 1 2 A() B(+) REF MS/TP ^*See EOL resistor jumper. 1 0 Relay Control OPEN AI Voltage ^To select AI for Thermistor T2 or T3 input, install jumper. Select Switch ^* Connect Jumper for EOL. Disconnect for no terminating resistor. 1 2 3 4 5 6 7 8 9 10 11 12 Baud Rate LSB MS/TP ADDRESS MSB Both jumpers installed from factory. Move one to Thermistor-Input-Select^ for T2 or T3 Thermistor Input, otherwise leave both on for 5V or 10V Analog In. Connect Analog In between AI and AI common. Connect Thermistor between AI and Thermistor +5V. O O O On On O On On Not de ned T2 Thermistor T3 Thermistor Analog In 5V or 10V Type Analog AI AI COM Therm. +5V Analog In (Close only one) SW1 Closed 5 V SW2 Open 10 V SW1 Open SW2 Closed Thermistor T2 or T3 input, use 5 V selection Contacts Relay N/C } COM 24 Vac/dc Common N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.25 x 2.75 x 1.75 (RIBMNW24B-BCAI) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTW24B-BCAI) Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac Notes: · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24B-BCAI-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTW24B-BCAI-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTW24B-BCAI-N4-GY) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. Units default to 95 (no units). · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below.^^ · PIC Statement available on website. http://www.functionaldevices.com/pdf/ pics/BACnet-BCAI_PICS.pdf Or scan QR code with your smart phone. BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), BI 2 (Dry contact binary input), AI 1 (Analog input) · Device Instance changed via Object Identifier Property of Device Object DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 DIP SWITCHES* 11 12 1 0 X 1 0 0 RELAY STATE** Auto Override on Override off * 0 = Open ; 1 = Closed ** Device must be powered for override All other combinations=9600 baud · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included. · For both T2 and T3, MIN_PRES_VAL must be set to -36 (real value) and MAX_PRES_VAL must be set to 66.3 (real value) for Celcius. For Fahrenheit, MIN_PRES_VAL must be set to -32.8 (real value) and MAX_PRES_VAL must be set to 151.34 (real value). · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps 24 Vac RIBMNW24B-BCAI or RIBTW24B-BCAI 24 Vac/dc Com Half-Wave Device 24 Vac Com ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). IN4004 (800) 888-5538 | www.functionaldevices.com 75 NETWORK COMPATIBLE RELAY RIBTW24B-BCAO Enclosed BACnet® MS/TP Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); One Binary Input (Dry Contact, Class 2); One Analog Output (0-5 Vdc, 0-10 Vdc, or 4-20 mA), One Analog Input (T2/T3 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. Thermistor Select Made in USA Meets "Buy American" of ARRA 2009 BI COM B I Analog Output () 4-20 mA (+) Analog Output () 0-5 Vdc 0-10 Vdc (+) 24 Vac/dc Power Therm. +5V AI COM AI REF LSB B(+) A() RELAYS MS/TP RELAY CONTROL 1 2 3 4 5 6 7 8 9 10 11 12 MSB MS/TP ADDRESS BAUD RATE J1: Jumper for EOL resistor Green LED=Network Status J2 J3 Analog In ON ON T3 Thermistor ON OFF T2 Thermistor OFF ON Not de ned OFF OFF 10 V 5 V 1 2 OPEN AI Voltage Select Switch Red LED=Relay Status J5: Install for 0-10 V Relay Contacts Pink LED=BI Status N/O N/C COM Dry Contact Binary Input Shown With Cover } SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Relay Activated Binary Input Status: Pink LED On = Activated Dimensions: 4.28 x 7.00 x 2.00 with .75 NPT Nipple Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Gold Flash: No Relay Override: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Magnetic Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 176 mA @ 24 Vac 150 mA @ 24 Vdc Notes: · Use a separate 24 Vac transformer, or an isolated 24 Vdc power supply to power-up this product. · Complete Installation Instructions: Bulletin B1756 available on website. www.functionaldevices.com/pdf/bulletins/ B1756_393218.pdf · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below. ^^ Thermistor Specifications: · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor Type 3 (T3) Precon 10 K @ 77°F (25°C) Model 3, (or equivalent.) Thermistor not included. · -35 to 10°C range in 1° steps / -31 to 50°F range in 1.8° steps 10 to 32°C range in 0.1° steps / 50 to 90°F range in 0.18° steps 32 to 100°C range in 1° steps / 90 to 212°F range in 1.8° steps BACnet® Details: · This model utilizes: BO 1 (Relay output), BI 1 (Dry contact binary input), AI 1 (Analog input), AO 1 (Analog output) · PIC Statement available on website. http://www.functionaldevices.com/pdf/ pics/RIBTW24B-BCAO_PICS.pdf Or scan QR code with your smart phone. · Addressing Specifications: Bulletin B2028 available on website. www.functionaldevices.com/pdf/bulletins/B2028_393243.pdf Analog Output Voltage (0-5 Vdc; 0-10 Vdc) Analog Output Current (4-20 mA) ANALOG OUTPUT ACCURACY AS A FUNCTION OF OUTPUT SPAN (USING STANDARD CONDITIONS *) Span 20% - 100% Span 10% - 100% Span 0% - 100% +/- 2% error +/- 5% error +/- 11% error +/- 2% error +/- 3% error +/- 12% error * Standard Conditions: Power Supply Input: 22 Vac/dc to 28 Vac/dc ; Loop Resistance (Analog Output 4-20 mA Loop): 530 Ohms max. Load Resistance [Analog Output Voltage (0-5 Vdc, 0-10 Vdc)]: 10 K Ohms min. ; Ambient Temperature: -30 to 140° F 0-5Vdc or 0-10 Vdc Temperature, Humidity, Pressure Transducer 76 AI AI Com Analog 10K Input RIBTW24B-BCAO Half-Wave Device 24 Vac 24 Vac/dc Com 24 Vac Com IN4004 ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). Functional Devices, Inc. | American Made. American Owned. RELAYS NETWORK COMPATIBLE DEVICE RIBMNWD12-BCDI 2.75 Track Mount BACnet® MS/TP Network 12 Binary Input Device; Optional End of Line Resistor (EOL) Included. } } MSTP 24 Vac/dc A() B(+) REF BI 1 BI 2 BI 3 BI 4 BI 5 BI 6 +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM Made in USA Meets "Buy American" of ARRA 2009 Green LED = Network Communication Red LED = Power } } } } } } 1 0 Not Used Baud Rate LSB Pink LED = Digital Input Status Connect Jumper for Dry Contact Operation. Disconnect for voltage input operation. 1 2 3 4 5 6 7 8 9 10 MS/TP ADDRESS Connect Jumper for EOL. MSB Disconnect for no terminating resistor. COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V } } } } } } BI 12 BI 11 BI 10 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Green LED: Network Communication Red LED: ON = Power Present Dimensions: 5.85 x 2.75 x 1.75 Track Mount: MT212-6 Mounting Track Provided Approvals: CE, RoHS Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Band Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) BI 9 BI 8 BI 7 Power Input Ratings: 41 mA @ 24 Vdc 53 mA @ 24 Vac Binary Input Ratings: Dry Contact: 3 mA @ 30 Vdc max. Voltage Input: 12 mA @ 25 Vac/dc max. BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Device Instance changed via Object Identifier Property of Device Object · Full wave rectified · Objects included in device are: BI 1 (Binary input) BI 7 (Binary input) BI 2 (Binary input) BI 8 (Binary input) BI 3 (Binary input) BI 9 (Binary input) BI 4 (Binary input) BI 10 (Binary input) BI 5 (Binary input) BI 11 (Binary input) BI 6 (Binary input) BI 12 (Binary input) · PIC Statement available on website. http://www.functionaldevices.com/pdf/pics/ RIBMNWD12-BCDI_PICS.pdf Or scan QR code with your smart phone. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 * 0 = Open ; 1 = Closed All other combinations=9600 baud Example of Dry Contact Input Operation Dry Contact N/C +V Vin COM Example of Voltage Input Operation Voltage Source + +V Vin COM Jumper Connected Jumper Disconnected (800) 888-5538 | www.functionaldevices.com 77 RELAYS NETWORK COMPATIBLE DEVICE RIBMNWD12-BC 2.75 Track Mount BACnet® MS/TP Network 12 Binary Input Device (With Accumulators); Optional End of Line Resistor (EOL) Included. } } MSTP 24 Vac/dc A() B(+) REF BI 1 / ACC 1 BI 2 / ACC 2 BI 3 BI 4 BI 5 BI 6 +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM +V Vin COM Made in USA Meets "Buy American" of ARRA 2009 Green LED = Network Communication Red LED = Power } } } } } } 1 0 Not Used Baud Rate LSB Pink LED = Digital Input Status Connect Jumper for Dry Contact Operation. Disconnect for voltage input operation. 1 2 3 4 5 6 7 8 9 10 MS/TP ADDRESS MSB Connect Jumper for EOL. Disconnect for no terminating resistor. } } } } } } COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V COM Vin +V BI 12 BI 11 BI 10 BI 9 BI 8 BI 7 TWO (ACCUMULATOR) INPUTS CAN BE USED FOR POWER MONITORING OR OTHER PULSE COUNTING APPLICATION. SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Green LED: Network Communication Red LED: ON = Power Present Dimensions: 5.85 x 2.75 x 1.75 Track Mount: MT212-6 Mounting Track Provided Approvals: CE, RoHS Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (DIP Switch Selectable) Power Input Ratings: 41 mA @ 24 Vdc 53 mA @ 24 Vac Max. Accumulator Frequency: 50 Hz Binary Input Ratings: Dry Contact: 3 mA @ 30 Vdc max. Voltage Input: 12 mA @ 25 Vac/dc max. BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 MS/TP Address - 121 Device ID - 277004 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique.) · Device Instance changed via Object Identifier Property of Device Object · Objects included in device are: } BI 1 (Binary input) Use Same ACC 1 (Accumulator) Physical Input } BI 2 (Binary input) Use Same ACC 2 (Accumulator) Physical Input BI 3 (Binary input) BI 4 (Binary input) BI 5 (Binary input) BI 6 (Binary input) BI 7 (Binary input) BI 8 (Binary input) BI 9 (Binary input) BI 10 (Binary input) BI 11 (Binary input) BI 12 (Binary input) · PIC Statement available on website. http://www.functionaldevices.com/pdf/pics/ RIBMNWD12-BC_PICS.pdf Or scan QR code with your smart phone. DIP SWITCHES* 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 BAUD RATE 9600 19200 38400 57600 76800 115200 * 0 = Open ; 1 = Closed All other combinations=9600 baud Example of Dry Contact Input Operation Dry Contact N/C +V Vin COM Jumper Connected Example of Voltage Input Operation Voltage Source + +V Vin COM Jumper Disconnected 78 Functional Devices, Inc. | American Made. American Owned. NETWORK COMPATIBLE RELAY RIBMW24B-44-BC 4.00 Track Mount BACnet® MS/TP Network Relay Device; Four Binary Outputs (20 Amp Relay SPDT + Override); Four Binary Inputs (Dry Contact Binary Inputs), 24 Vac/dc Power Input, Optional End of Line Resistor (EOL) Included. DIP 1 DIP 2 REF B(+) A() 1 2 3 4 5 6 7 8 9 10 12345678 1 0 Baud Rate LSB MSB MSTP Relay 1 Contacts Relay 2 Contacts MS/TP ADDRESS BO1 BO2 RELAY OVERRIDE Connect Jumper Red LEDs BO3 BO4 for terminating resistor. Disconnect for no Network Status terminating resistor. Green LED Pink LEDs BI1 BI2 BI3 BI4 Relay 3 Contacts Relay 4 Contacts Power Input BO1 COM BO1 N/O BO1 N/C BO2 COM BO2 N/O BO2 N/C Made in USA Meets "Buy American" of ARRA 2009 RELAYS BO3 N/C BO3 N/O BO3 COM BO4 N/C BO4 N/O BO4 COM BI1 COM BI1 BI2 COM BI2 BI3 COM BI3 BI4 COM BI4 24 Vac/dc Comm SPECIFICATIONS # Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.00 L x 4.27 W x 1.34 H Track Mount: MT4-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Gold Flash: No Relay Override Switch: DIP Switch Control Network Media: Twisted Pair 22-24AWG, shielded recommended Terminations: Functional Devices product installed at both ends of the MS/TP network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the MS/TP network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600, 76800, 115200 (Dip Switch Selectable) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 120/277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 24 Vac : 400 mA 24 Vdc : 190 mA NEED AN ENCLOSURE? ORDER MODEL MH1210 (PAGE 142) NEED A POWER SUPPLY AND AN ENCLOSURE? ORDER MODEL CTRL-PS (PAGE 113) & AT4-8 (PAGE 152) BACnet® Details: · MS/TP Address & Baud Rate must be set prior to power up via DIP switches. · Device ID will default to 277XXX where XXX is the MS/TP Address. Examples: MS/TP Address - 004 Device ID - 277004 MS/TP Address - 121 Device ID - 277121 · Device ID can be changed via network command. Once changed, it will no longer default to 277XXX. (MS/TP Address & Device ID must be unique) · This model utilizes: BO1, BO2, BO3, BO4, (Relay outputs), BI1, BI2, BI3, BI4 (Dry contact inputs) · Device Instance changed via Object Identifier Property of Device Object · Each unit is 1/8 unit load · PIC Statement available on website. http://www.functionaldevices.com/pdf/ pics/RIBMW24B-44-BC_PICS.pdf Or scan QR code with your smart phone. DIP 1 DIP 2 DIP Switches 1-7 8 9 10 0 0 0 0 0 1 See Bulletin B1082 for 0 1 0 full MS/TP 0 1 1 Addressing 1 0 0 1 0 1 All other combinations=9600 baud Baud Rate 9600 19200 38400 57600 76800 115200 · Dry contact digital input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to report back to the network. Relay BO1 BO2 BO3 BO4 Relay State** Auto ON OFF Auto ON OFF Auto ON OFF Auto ON OFF 1 2 1 X X X 0 X X 1 X X X 0 X X X X X X X X X X X X DIP Switches* 3 4 5 6 X X 0 X X X 1 X X X 0 X X X X 0 X X X 1 X X X 0 1 X X X X X X X 0 X X X X 1 X X X X X X X 0 X X 7 8 X X X X X X X X X X X X 0 X 1 X 0 X X 0 X 1 X 0 * 0 = Open ; 1 = Closed ** Device must be powered for override (800) 888-5538 | www.functionaldevices.com 79 RELAYS SW 1 SW 2 Pink LED = BI Status Green LED = Ad-Hoc Status Yellow LED = Infrastructure Status Green LED = Device Status Red LED = Relay Status BI COM BI 24 Vac/dc Common NETWORK COMPATIBLE RELAY RIBTW24B-WI-N4 Enclosed Wifi IEEE 802.11 b/g Network Enclosed I/O Device: One Discrete Output (20 Amp Relay SPDT + Override), One Discrete Input (Dry Contact, Class 2); 24 Vac/dc DIP Switch CLOSED X 12 OPEN Relay State AUTO Override ON Override OFF RESET to Factory Defaults Pushbutton (Activate with insulated tool) Relay Contacts N/C N/O COM Shown With Cover Code Version 4.0.1 Made in USA Meets "Buy American" of ARRA 2009 Wi-Fi RIBTM SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Operate Time: 18ms Pink LED: Digital Input Status Green LED: Wifi Ad-Hoc Status Yellow LED: Wifi Infrastructure Status Green LED: Device Status Red LED: Relay Status Dimensions: 4.28 x 7.00 x 2.00 with .75 NPT Nipple Approvals: UL Listed, UL916, C-UL FCC, CE, RoHS, Wifi Certified ASD Device Housing Rating: UL Accepted for Use in Plenum, NEMA 4 Gold Flash: No Relay Override Switch: DIP Switch Control Wifi: IEEE 802.11 b/g/n Compatible, (G) 54 Mbps Data Rate 95 dBm Min. Sensitivity +16 dBm Max Output Power Currently Unsecured Connection in Ad-Hoc (WPA-PSK or WPA-2-PSK Available) Supports PING and ARP DSSS Modulation Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 200 mA Max @ 24 Vac 200 mA Max @ 24 Vdc Available TCP/IP Settings: · IP Address (Static) · Port Number · Subnet Mask · Gateway Address · Ad-Hoc mode · Infrastructure mode · Scan for wireless networks Device Settings: · Local Override · Reset to Network Defaults Pushbutton Power Input: 24 Vac = Terminal Strip (20 Vac min. ; 28 Vac max.) 24 Vdc = Terminal Strip (24 Vdc min. ; 28 Vdc max.) Device Settings by Network: · Power up default relay state · Host name and location labels · Relay bound to digital input · Setup instructions available on website. http://www.functionaldevices.com/pdf/ bulletins/B1802_393224.pdf Or scan QR code with your smart phone. 80 Functional Devices, Inc. | American Made. American Owned. RELAYS NETWORK COMPATIBLE RELAY RIBTW2401B-WIUI-N4 Wifi IEEE 802.11 b/g Network Enclosed I/O Device: One Discrete Output (20 Amp Relay SPDT + Override), One Discrete Input (Dry Contact, Class 2); Two Universal Inputs; 24 Vac/dc, 120 Vac Power AUTO OFF ON Relay Operation Universal Input 1 Universal Input 2 RESET to Factory Defaults Pushbutton + 5V UI1 COM UI1 UI2 420 420 + 5V UI2 COM COM 24Vac 24Vdc 24V Optional Power Input SW 1 X SW 2 (Activate with insulated tool) COM DI General Purpose Dry Contact Input Term A: (Not used) Term B: 120 Vac Term C: Neut 120 Vac Optional Power Input COM N/C N/O Relay Contacts SPECIFICATIONS Pink LED = DI Status Green LED = Ad-Hoc Status Yellow LED = Infrastructure Status Green LED = Device Status Red LED = Relay Status Shown With Cover Code Version 4.0.9.1.0 Made in USA Meets "Buy American" of ARRA 2009 Wi-Fi RIBTM # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Operate Time: 18ms Pink LED: Digital Input Status Green LED: Wifi Ad-Hoc Status Yellow LED: Wifi Infrastructure Status Green LED: Device Status Red LED: Relay Status Dimensions: 4.28 x 7.00 x 2.00 with .75 NPT Nipple Wires: 16, 600V Rated Approvals: UL Listed, UL916, C-UL FCC, CE, RoHS, Wifi Certified ASD Device Housing Rating: UL Accepted for Use in Plenum, NEMA 4X Gold Flash: No Relay Override Switch: DIP Switch Control Wifi: IEEE 802.11 b/g/n Compatible, (G) 54 Mbps Data Rate 95 dBm Sensitivity +16 dBm Output Power (WPA-PSK or WPA-2-PSK Available) Supports PING and ARP DSSS Modulation Security: Customer can choose to have Webpage and Controller Commands authentication-secured with Username and Password. Contact Ratings: 20 Amp Resistive @ 277 Vac 5 Amp Resistive @ 480 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 1 HP @ 120 Vac 2 HP @ 277 Vac Power Input Ratings: 158 mA Max @ 24 Vac 110 mA Max @ 24 Vdc 55 mA Max @ 120 Vac Available TCP/IP Settings: · IP Address (Static) · Port Number · Subnet Mask · Gateway Address · Ad-Hoc mode (Default) · Infrastructure mode · Scan for wireless networks Device Settings: · Local Override · Reset to Network Defaults Pushbutton Power Input: 24 Vac = Terminal Strip (20 Vac min. ; 28 Vac max.) 24 Vdc = Terminal Strip (24 Vdc min. ; 28 Vdc max.) 120 Vac = Wht/Blk Wire Neutral = Wht/Yel Wire Device Settings by Network: · Power up default relay state · Host name and location labels · Relay bound to digital input · Username and Password security: Note: There will be no security if password field is left blank. A password may be entered that will secure the webpage as well as Controller Commands. Eight alpha-numerical characters case-sensitive. · Setup instructions available on website. http://www.functionaldevices.com/pdf/ bulletins/B1783_393223.pdf Or scan QR code with your smart phone. CAUTION: Remove all connections to UI 1 and UI 2 when setting input. Universal Input: Configurable by internal device web page, accessible in either Ad-Hoc or Infrastructure. · Analog value returned, user configurable min. and max. scale, and label, 0-5 Vdc, 0-10 Vdc, or 4-20 mA* · Direct temperature reading from Type T2 Thermistor. Connect between +5 Vdc and UI input. · Digital Input, connect between +5 Vdc and UI input. * 4-20 mA, when used, requires jumper to be installed on UI set for 4-20 mA input. Jumper MUST be removed when UI input used as anything other than 4-20 mA. For application manual, please visit: www.functionaldevices.com (800) 888-5538 | www.functionaldevices.com 81 RELAYS NETWORK COMPATIBLE RELAYS RIBMNW24B-MBAI 2.75" Track Mount Modbus® RTU Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. RIBTW24B-MBAI Enclosed Modbus® RTU Network Relay Device; One Binary Output (20 Amp Relay SPDT + Override); Two Binary Inputs (Dry Contact, Class 2); One Analog Input (T2 Thermistor / 0-5 Vdc / 0-10 Vdc); 24 Vac/dc Power Input; Optional End of Line Resistor (EOL) Included. Made in USA Meets "Buy American" of ARRA 2009 Green LED=Network Status Red LED=Relay Status Pink LED=BI 1 Status Pink LED=BI 2 Status BI 1 COM BI 1 BI 2 COM BI 2 5 V 10 V 1 2 A() B(+) REF OPEN ^ To select AI for Thermistor Standard RS-485 Modbus® RTU Protocol. AI Voltage Select Switch T2 input, install jumper. EOL termination resistor jumper. 1 0 Connect jumper for terminating resistor. Relay Control 1 2 3 4 5 6 7 8 9 10 11 12 Baud Rate LSB Modbus® RTU ADDRESS MSB Both jumpers installed from factory. Remove left jumper from Thermistor-Input-Select^ for T2 Thermistor Input, otherwise leave both on for 5V or 10V Analog In. Connect Analog In between AI and AI common. Connect Thermistor between AI and Thermistor +5V. O O Not de ned O On T2 Thermistor On On Analog In 5V or 10V Type Analog AI AI COM Therm. +5V Analog In (Close only one) SW1 Closed 5 V SW2 Open 10 V SW1 Open SW2 Closed Thermistor T2 input, use 5 V selection Contacts Relay N/C } COM 24 Vac/dc Common N/O SPECIFICATIONS # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 18ms Network Communication: Green LED Relay Status: Red LED On = Activated Current Sensor Status: Pink LED On = Activated Binary Input Status: Pink LED On = Activated Dimensions: 6.25 x 2.75 x 1.75 (RIBMNW24B-MBAI) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBTW24B-MBAI) Track Mount: MT212-6 Mounting Track Provided Approvals: CE, UL Listed, UL916, C-UL, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Also available NEMA 4 / 4X Gold Flash: No Relay Override Switch: DIP Switch Control Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac 16 Amp Electronic Ballast @ 277 Vac (N/O) 10 Amp Tungsten @ 120 Vac (N/O) 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Power Input Ratings: 81 mA @ 24 Vdc 111 mA @ 24 Vac Network Media: Twisted Pair 22-24AWG, shielded recommended, EIA/TIA-485 (standard RS485) Terminations: Functional Devices product installed at both ends of the standard RS485 Modbus® RTU network Use 120 end of line resistors. All other cases Follow instructions from the device installed at the end of the Modbus® network. Polarity: Network is polarity sensitive Baud Rate: 9600, 19200, 38400, 57600 (DIP Switch Selectable) Notes: · Modbus®Address & Baud Rate must be set prior to power up via DIP switches. · Order NEMA 4 housing by adding "-N4" to end of model number. (RIBTW24B-MBAI-N4) · Order with grey lid by adding "-GY" to end of model number. (RIBTW24B-MBAI-GY) · Order NEMA 4 housing with grey lid by adding "-N4-GY" to end of model number. (RIBTW24B-MBAI-N4-GY) · This model utilizes: Physical coil 1 (Relay output) Physical binary input 1 (Dry contact binary input) Physical binary input 2 (Dry contact binary input) Physical input register AI 1 (Analog input) · Thermistor Type 2 (T2) Precon 10 K @ 77°F (25°C) PN ST-R24, Model 24, (or equivalent.) Thermistor not included. (Range -39 to 187°F) · For all versions, raw analog default settings are 0 and 1023 (real), respectively. · When connecting 24 Vac to both the RIB(s) and a half-wave device, damage to device can occur. Option 1: Use separate transformers for each device. Option 2: Add diode between devices, see Option 2 note below.^^ · Address and Baud Rate Settings on Bulletin B1676 available on website. http://functionaldevices.com/pdf/bulletins/B1676_393208.pdf Or scan QR code with your smart phone. DIP SWITCHES* BAUD RATE DIP SWITCHES* RELAY STATE** 8 9 10 0 0 0 0 0 1 0 1 0 0 1 1 All other combinations=9600 baud 9600 19200 38400 57600 11 12 1 0 Auto X 1 Override on 0 0 Override off * 0 = Open ; 1 = Closed ** Device must be powered for override · Dry contact binary input is a general purpose input that is not tied to the relay internally. Can be used with any dry contact switching device, such as a current sensor, to feed back to the network. Modbus® is a registered trademark of Schneider Electric licensed to the Modbus Organization, Inc. 24 Vac RIBMNW24B-MBAI or RIBTW24B-MBAI 24 Vac/dc Com Half-Wave Device 24 Vac Com ^^ Option 2: Add diode on 24 Vac power (Com) interconnection between devices. Band on diode faces towards RIB(s). IN4004 82 Functional Devices, Inc. | American Made. American Owned. RELAYS SPECIALTY PERIPHERAL CONTROLS Fan Safety Alarm Circuits I/O Expanders Manual Analog Override Switch Made in the U.S.A. Meets the "Buy American" provisions of Section 1605 of the American Recovery and Reinvestment Act of 2009 (ARRA). If we do not already build a device with specifications or packaging configurations you require, we will be happy to quote and design one for you. Functional Devices, Inc. is actively involved in the development, manufacturing, and production of special peripheral devices. They are either variations of existing Functional Devices products or entirely unique devices. We will help provide you with a product to fit your specific needs. Please contact us so we may review your project and special requirements. FAN SAFETY ALARM CIRCUITS MODEL # RIBMNLB · RIBLB · RIBMNLB-6 · RIBMNLB-4 · RIBMNLB-2 · RIBMNLB-1 · RIBLB-6 · RIBLB-4 · RIBLB-2 · RIBMNLB-6NO · RIBMNLB-4NO · RIBMNLB-2NO · RIBLB-6NO · RIBLB-4NO · RIBLB-2NO · POWER INPUT 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac 24 Vac ALARM CIRCUITS 4 4 6 4 2 2 6 4 2 6 4 2 6 4 2 CONTACTS SWITCH ENCLOSED · · · · · · · NOTES NEW NEW NEW NEW NEW NEW NEW SPEC PAGE 84 84 85 85 85 87 85 85 85 86 86 86 86 86 86 I/O EXPANDERS MODEL # RIBMN24Q2C 1 POWER INPUT · 24 Vac/dc RIBMN24Q3C · 24 Vac/dc RIBMN24Q4C · 24 Vac/dc RIBMN24Q4C-PX · 24 Vac/dc RELAYS 2 3 4 4 CONTACTS 2 SPDT 3 SPDT 4 SPDT 4 SPDT SWITCH (Quick reference only. See individual spec page for more information.) ENCLOSED NOTES SPEC PAGE 87 88 88 89 MANUAL ANALOG OVERRIDE SWITCH MODEL # RIBMNA1D0 POWER INPUT 24 Vac/dc RELAYS SWITCH Manual / Auto = UL Listed : UL916 Energy Management, UL864 Fire ; USA & Canada 1= UL Listed : UL916 Energy Management ; USA & Canada ENCLOSED · NOTES SPEC PAGE 89 (800) 888-5538 | www.functionaldevices.com 83 RELAYS FAN SAFETY ALARM CIRCUITS RIBMNLB 2.75 Track Mount AHU Fan Safety Alarm Circuit, 24 Vac Power Input RIBLB Enclosed AHU Fan Safety Alarm Circuit, 24 Vac Power Input Power Input 4A Max. Dry Contact Inputs (From Field) Powered Contact Outputs 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 2mA @ 24Vac/dc 3A @ 24Vac /dc 750mA @ 24Vac/dc 1 2 24 Vac/dc Power On 3 4 Low Limit 1 5 Static Pressure Limit 1 6 Smoke Detector/FA Low Limit On Static Smoke Pressure Detector/FA On On Latched Input Selector DIP Switch Latch Reset Low Limit Relay Static Pressure Relay Low Limit Static Pressure Digital In Digital In 10 11 12 13 1 7 Fan Status Fan Status On 1 8 24V COM Actuator Power 1 9 24V COM Fan Safety Smoke Detector/ FA Relay Fan Status Relay Master Relay Master Relay On Smoke Detector/ Fan Status FA Digital In Digital In 14 15 16 17 For Indoor Use in Dry Locations 8A @ 2424Vac/dc J1 Jumper 8A @ 2424Vac/dc 8A @ 2424Vac/dc 8A @ 2424Vac/dc Dry Contact Outputs (To Controller) Dry Contact Output 10A @ 277 Vac 10A @ 30 Vdc 1/2 HP@120/240Vac B300 Pilot Duty CAN BE USED TO ISOLATE FIELD DEVICES FROM EACH OTHER AND FROM CONTROLLER, NOT ONLY FAN CIRCUITS SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 250ms Power Input: 4 Amp @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.000 x 2.750 x 1.200 (RIBMNLB) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBLB) Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL864, C-UL, CE, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved Gold Flash: No Override Switch: No Notes: · RIBMNLB and RIBLB have four Alarm Inputs and one Master Alarm. Panel Black Black RC-1 5Amp White White Green TX-1 1 x 1 24Vac 1 x 2 DC-1 Power 24Vac COM DC-1 DO-3 A master relay will open if any one of the normally-closed (N/C) inputs open. LED status of all outputs and the master relay is provided. The RIBMNLB is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB is enclosed in a NEMA 1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The master relay has two general-purpose outputs: one 24 V output terminal and one dry contact output rated up to 10 Amp @ 277 Vac. Fan status contact controls actuator power. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown. Model RIBMNLB combines all the relay logic to facilitate fan status, fan safety control, and damper actuator control. It is intended for use in a circuit that will control fan start/stop and fan safety shut-down circuit monitors three critical inputs: · Low-limit freeze protection (to stop fan and remove power from damper actuator) · Static pressure (to monitor for hi/low pressure condition) · Smoke detector / fire alarm Master relay opens to shut down AHU when any Normally Closed input opens. Integral DIP switch allows any input to be latched. Input can be reset with push button or by cycling unit power. Installing J1 jumper allows Fan Status input to control Master Relay, like the other 3 inputs. Digital inputs to controller 1 R4 FS-S 24Vac 16 Fan Status DI 17 R1 LL-A 10 Low Limit DI 11 R2 SP-A 12 Static Press Alarm DI 13 R3 Smoke/Fire Alarm 14 Smoke / Fire Alarm DI 15 DL-1 2 24Vac R1 LL-A R2 SP-A R3 SMK/FA 1 9 PB-1 R1 LL-A R1 LL-A 3 4 1 5 R2 SP-A 1 6 R3 SMK/FA 1 R4 FS-S 7 RIBMNLB (Track Mount) RIBLB (Enclosed) At power-up, delay 2 sec before DL-1 becomes activated R4 FS-S 1 8 DL-1 Made in USA Meets "Buy American" of ARRA 2009 CODE VER. 1.0 Field H 120Vac N Emergency Power G with ground X1 120Vac X2 Starter H O A Contactor Ols RIBTU2C Wht/Blu Blu Yel Wht/Yel Org Gry/Wht Gry Prp Wht/Prp Brn Fan Safety Relay Low Limit Static Pressure Smoke Detector / Fire Alarm Tn To Motor Status FS-S RIBX Series Fan Status Actuator Power This drawing represents: · Only Low Limit Latch Set · J1 Jumper Not Installed 84 Functional Devices, Inc. | American Made. American Owned. FAN SAFETY ALARM CIRCUITS RIBMNLB-6/-4/-2 2.75 Track Mount AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input Isolated Dry Contact Outputs, Each Rated 1.5A @ 24 Vac/dc RIBLB-6/-4/-2 Enclosed AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input 3A Total Sourced from 24 Vac/dc Input Made in USA Meets "Buy American" of ARRA 2009 R7 N/O POLE 2 R7 N/O POLE 1 R7 N/O POLE 1 RELAYS R1 OUT N/C R1 R2 OUT N/C R3 OUT N/C R4 OUT N/C R2 R3 R4 R5 OUT N/C R5 R6 OUT N/C R6 COM N/O COM N/O CLOSE R1 R2 R3 R4 R5 R7 R6 R1-R6 CLOSE TO BYPASS COM 24Vac/dc 10A @ 277 Vac 10A @ 24 Vdc 1/2 HP @ 120/240 Vac B300 Pilot Duty Max. Isolated Dry Contact Output R1-R6 N/C INPUTS Alarm Alarm Alarm Alarm Alarm Input 1 Input 2 Input 3 Input 4 Input 5 Each Input Pulls 39mA from 24 V Input SPECIFICATIONS Alarm Input 6 4A Max Power Input Green LED 24 V Power Master Alarm Indicator Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Power Input: 4 Amp @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 6.000 x 2.750 x 1.750 (RIBMNLB-6) 4.740 x 2.750 x 1.750 (RIBMNLB-4) 3.200 x 2.750 x 1.750 (RIBMNLB-2) 4.28 x 7.00 x 2.00 with .75 NPT Nipple (RIBLB-6/-4/-2) Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS Housing Rating: UL Listed, NEMA 1, C-UL, CE Approved, UL Accepted for Use in Plenum, Gold Flash: No Override Switch: No Notes: · RIBMNLB-6 and RIBLB-6 shown above. · RIBMNLB-4 and RIBLB-4 have four Alarm Inputs and one Master Alarm. RIBMNLB-2 and RIBLB-2 have two Alarm Inputs and one Master Alarm. 10A @ 277 Vac (Typically used to shut down fan) 24 Vac (Typically used to shut down other relays) Low Temp Alarm to DDC Controller High Temp Alarm to DDC Controller Models RIBMNLB-6, RIBMNLB-4, and RIBMNLB-2; and RIBLB-6, RIBLB-4, and RIBLB-2 are simply devices that combine a common relay-logic function into a small, easy-to-install, and less expensive form. A master relay will open if any one of the normally-closed (N/C) inputs open. There are six, four, or two inputs depending on the model chosen. LED status of all inputs, the master relay, and power input is provided. Bypass of un-used inputs is also provided. The RIBMNLB series is provided with mounting track for mounting in user-provided electrical enclosures. The RIBLB series is enclosed in a NEMA-1, 4 x 7 enclosure with a clear lid to allow viewing of the status LEDs. The master relay has three general-purpose outputs: two 24 V output terminals and one dry-contact output rated up to 10 Amp @ 277 Vac (terminals on RIBMNLB series, wires on RIBLB series.) The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown. SELECTION GUIDE Model# Inputs RIBMNLB-6 6 MT212 Mounting Track RIBMNLB-4 4 MT212 Mounting Track RIBMNLB-2 2 MT212 Mounting Track RIBLB-6 6 PE6020 Enclosure RIBLB-4 4 RIBLB-2 2 PE6020 Enclosure PE6020 Enclosure Low Press Alarm to DDC Controller High Press Alarm to DDC Controller Smoke Alarm #1 to DDC Controller Smoke Alarm #2 to DDC Controller R7-2 R1-1 R2-1 R3-1 R4-1 R5-1 R6-1 R7 R7-1 Close bypass switch if input not in use. R1-2 Input 1 Bypass R1 R1-3 Input 1 Alarm Indicator R2-2 Input 2 Bypass R2 R2-3 Input 2 Alarm Indicator R3-2 Input 3 Bypass R3 R3-3 Input 3 Alarm Indicator R4-2 Input 4 Bypass R4 R4-3 Input 4 Alarm Indicator R5-2 Input 5 Bypass R5 R5-3 Input 5 Alarm Indicator R6-2 Input 6 Bypass R6 R6-3 Input 6 Alarm Indicator RIBMNLB-6 (Track Mount) RIBLB-6 (Enclosed) (800) 888-5538 | www.functionaldevices.com 24 Vac Power Input Typical alarm inputs shown below. Any alarm inputs may be used and in any order. (Alarm inputs must be N/C.) Input 1 Low Temp Alarm Input 2 High Temp Alarm Input 3 Low Press Alarm Input 4 High Press Alarm Input 5 Smoke Alarm #1 Input 6 Smoke Alarm #2 85 RELAYS R1-R6 N/C INPUTS FAN SAFETY ALARM CIRCUITS RIBMNLB-6NO/-4NO/-2NO 2.75 Track Mount AHU Fan Safety Alarm and General Purpose Logic Circuit, 24 Vac/dc Power Input Isolated Dry Contact Outputs, Each rated 1.5A @ 24 Vac/dc Each 1.5A @ 24 Vac/dc (wet or dry) R1 OUT N/O R1 R2 OUT N/O R3 OUT N/O R4 OUT N/O R2 R3 R4 R5 OUT N/O R5 R6 OUT N/O R6 CLOSE R1 R2 R3 R7 N/O POLE 1 R7 N/O POLE 2 R4 R5 R6 R1-R6 CLOSE TO BYPASS Master COM 24Vac/dc Legend for Jumper Selection Dry = 24V = Alarm Input 1 Alarm Alarm Alarm Alarm Input 2 Input 3 Input 4 Input 5 Each input can accept 39mA Alarm Input 6 4A Max Power Input Green LED 24 Vac/dc Power Master Alarm Indicator SPECIFICATIONS Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Power Input: 4 Amp @ 24 Vac/dc ; 50-60 Hz Alarm Status: LED On = Activated Dimensions: 5.120 x 2.750 x 1.750 (RIBMNLB-6NO) 4.020 x 2.750 x 1.750 (RIBMNLB-4NO) 3.910 x 2.750 x 1.750 (RIBMNLB-2NO) Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, UL864, C-UL, CE, RoHS Gold Flash: No Override Switch: No Models RIBMNLB-6NO, RIBMNLB-4NO, and RIBMNLB-2NO are simply devices that combine a common relay-logic function into a small, easy-to-install, and less expensive form. A master relay will open if any one of the normally-closed (N/C) inputs open. There are six, four, or two inputs depending on the model chosen. LED status of all inputs, the master relay, and power input is provided. Bypass of un-used inputs is also provided. The RIBMNLB series is provided with mounting track for mounting in user-provided electrical enclosures. The master relay has two general-purpose outputs: both can be jumper selected at 24 V (sourced from input) or dry contact. The most common application is an Air Handling Unit (AHU) fan-safety-shutdown where the master relay is used to shutdown the fan. Contact closure outputs are provided so that a DDC controller can determine the cause of a shutdown. Notes: · RIBMNLB-6NO shown. · RIBMNLB-4NO has four Alarm Inputs and one Master Alarm. · RIBMNLB-2NO has two Alarm Inputs and one Master Alarm. · This is a half wave device. When connecting 24 Vac to both this device and a full-wave device, damage to device can occur. Input 1 24 Vac Input Power Com 24 V R1-3 Input 2 R2-3 Input 3 R3-3 Input 4 R4-3 Input 5 R5-3 Input 6 R6-3 R1-1 R2-1 R3-1 Input 1 Bypass Input 2 Bypass Input 3 Bypass R7-3 R7-1 Output Con guration Jumper Dry Contact Wet Contact P1 P2 P3 P4 R4-1 Input 4 Bypass 24 Vac Preset Indicator R1 R1 Alarm Indicator R2 R2 Alarm Indicator R3 R3 Alarm Indicator R4 R4 Alarm Indicator R5-1 Input 5 Bypass R5 R5 Alarm Indicator R6 R6 Alarm Indicator R6-1 R7 Input 6 Bypass R7 Alarm Indicator R7-2 Output Con guration Jumper R7-1 Dry Contact Wet Contact P5 P6 P7 P8 R7-2 RIBMNLB-6NO SELECTION GUIDE Model# Inputs RIBMNLB-6NO 6 MT212 Mounting Track RIBMNLB-4NO 4 MT212 Mounting Track RIBMNLB-2NO 2 MT212 Mounting Track Made in USA Meets "Buy American" of ARRA 2009 R1-2 R2-2 R3-2 To DDC Controller R4-2 R5-2 R6-2 86 Functional Devices, Inc. | American Made. American Owned. FAN SAFETY ALARM CIRCUIT RIBMNLB-1 2.75" Track Mount General Purpose Latching Logic Circuit; One Latching/Fault Input (Dry Contact, Class 2); 24 Vac/dc Power Input 24 Vac/dc Comm Power Input RESET Pushbutton Latch/Fault Input · MANUAL RESET · ONE ALARM OUTPUT · ONE RELAY OUTPUT Made in USA Meets "Buy American" of ARRA 2009 RELAYS N/C Com N/O N/O Com N/C Power Latch/Fault Status Status SPECIFICATIONS # Relays & Contact Type: One (1) DPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Operate Time: 8ms Green LED: Power Status (ON: Power present) Red LED: Fault Status (ON: Latched/Fault State) Dimensions: 4.00 x 2.75 x 1.25 Track Mount: MT212-4 Mounting Track Provided Approvals: CE, UL Listed, UL864, C-UL, RoHS Gold Flash: No Relay Override Switch: No Fault Reset Switch: Yes Contact Ratings: 10 Amp Resistive @ 30Vdc 10 Amp General Use @ 277Vac 1/2 HP @ 120/240Vac (N/O) 1/3 HP @ 120/240Vac (N/C) Power Input Ratings: 53 mA @ 24Vac 25 mA @ 24Vdc 50/60 Hz Alarm Fault Application: When the Latch/Fault Input is Closed (Normal state), the Relay is activated, and Red LED is Off. When Latch/Fault Input Opens (Alarm state), the Relay deactivates, and Red LED turns On. Until the Latch/ Fault Input is Closed AND either power is cycled or the RESET button is pressed, relay will remain in the Alarm state. Notes: · Fault conditions must last for at least 500 ms in order for the unit to go into Alarm state. · Reset signal, whether via pushbutton or power cycling, must last for at least 30 ms in order to reset the device to go from Alarm state to Normal state. I/O EXPANDER RIBMN24Q2C 2.75 Track Mount 2 Output I/O Expander with 24 Vac/dc Power Input and 0-10 Vdc / 0-5 Vdc Control Input AI Comm 0-10 Vdc / 0-5 Vdc 24 Vac/dc Comm * Relay 1 Relay 2 0-10 VDC CONTROL VOLTAGE 0-2.117Vdc 0-5 VDC * CONTROL VOLTAGE 0-1.058Vdc RELAY 1 STATUS OFF RELAY 2 STATUS OFF 2.745-4.627Vdc 1.373-2.313Vdc ON OFF 5.255-7.137Vdc 2.628-3.568Vdc OFF ON 7.765-10.000Vdc 3.883-5.000Vdc ON ON Made in USA Meets "Buy American" of ARRA 2009 GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS, OR MULTI-STAGE HEATING N/C COM N/O N/C COM N/O SPECIFICATIONS # Relays & Contact Type: Two (2) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 3.100 x 2.750 x 1.750 Track Mount: MT212-4 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 100mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders. (800) 888-5538 | www.functionaldevices.com 87 RELAYS I/O EXPANDER RIBMN24Q3C 2.75 Track Mount 3 Output I/O Expander with 24 Vac/dc Power Input and 0-10 Vdc / 0-5 Vdc Control Input AI Comm 0-10 Vdc / 0-5 Vdc 24 Vac/dc Comm 0-10 VDC 0-5 VDC * RELAY RELAY RELAY CONTROL CONTROL 1 2 3 VOLTAGE VOLTAGE STATUS STATUS STATUS 0-0.988Vdc 0-0.494Vdc OFF OFF OFF * 1.366-2.242Vdc 0.683-1.121Vdc ON OFF OFF Made in USA Meets "Buy American" of ARRA 2009 2.620-3.496Vdc 1.310-1.748Vdc OFF ON OFF Relay 1 Relay 2 Relay 3 3.876-4.752Vdc 1.938-2.376Vdc ON ON OFF 5.130-6.006Vdc 2.565-3.003Vdc OFF OFF ON 6.386-7.262Vdc 3.193-3.631Vdc ON OFF ON N/C COM N/O N/C COM N/O N/C COM N/O SPECIFICATIONS 7.640-8.516Vdc 3.820-4.258Vdc OFF ON ON 8.896-10.000Vdc 4.448-5.000Vdc ON ON ON GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS, OR MULTI-STAGE HEATING # Relays & Contact Type: Three (3) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 4.000 x 2.750 x 1.750 Track Mount: MT212-4 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 150mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders. I/O EXPANDER RIBMN24Q4C 2.75 Track Mount 4 Output I/O Expander with 24 Vac/dc Power Input and 0-10 Vdc / 0-5 Vdc Control Input 0-10 VDC CONTROL VOLTAGE 0-0.372Vdc 0-5 VDC * CONTROL VOLTAGE 0-0.186Vdc RELAY RELAY RELAY RELAY 1 2 3 4 STATUS STATUS STATUS STATUS OFF OFF OFF OFF Made in USA Meets "Buy American" of ARRA 2009 AI Comm 0-10 Vdc / 0-5 Vdc 24 Vac/dc Comm 0.726-1.000Vdc 0.363-0.500Vdc ON OFF OFF OFF 1.354-1.626Vdc 0.677-0.813Vdc OFF ON OFF OFF 1.982-2.254Vdc 0.991-1.127Vdc ON ON OFF OFF * 2.608-2.882Vdc 1.304-1.441Vdc OFF OFF ON OFF 3.236-3.508Vdc 1.618-1.754Vdc ON OFF ON OFF 3.864-4.136Vdc 1.932-2.068Vdc OFF ON ON OFF Relay 1 Relay 2 Relay 3 Relay 4 4.492-4.764Vdc 2.246-2.382Vdc ON ON ON OFF 5.118-5.392Vdc 2.559-2.696Vdc OFF OFF OFF ON N/C COM N/O N/C COM N/O N/C COM N/O N/C COM N/O 5.746-6.018Vdc 2.873-3.009Vdc ON OFF OFF ON 6.374-6.646Vdc 3.187-3.323Vdc OFF ON OFF ON 7.000-7.274Vdc 3.500-3.637Vdc ON ON OFF ON 7.628-7.902Vdc 3.814-3.951Vdc OFF OFF ON ON GREAT FOR STAGING LOADS SUCH AS CHILLERS, PUMPS, ACTUATORS, OR MULTI-STAGE HEATING 8.256-8.528Vdc 4.128-4.264Vdc ON OFF ON ON 8.884-9.156Vdc 4.442-4.578Vdc OFF ON ON ON SPECIFICATIONS 9.510-10.000Vdc 4.755-5.000Vdc ON ON ON ON # Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Dimensions: 4.950 x 2.750 x 1.750 Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 200mA max. Notes: · Must clip resistor in white box for 0-5Vdc.* · Custom Programming Available for Large Orders. 88 Functional Devices, Inc. | American Made. American Owned. RELAYS I/O EXPANDER RIBMN24Q4C-PX 2.75 Track Mount 4 Output Field Adjustable Staging Threshold Relay Module with 24 Vac/dc Power and 0-10 Vdc Control Input AI Comm () 0-10 Vdc 24 Vac/dc Comm (+) Analog }Input Power }Input Setup Display DN UP Relay 1 Relay 2 Relay 3 Relay 4 · CONTROL FOUR RELAY OUTPUTS WITH ONE (0-10 VDC) ANALOG SIGNAL FROM CONTROLLER OR THERMOSTAT · CAPABILITY TO SET DESIRED ON AND OFF VOLTAGES FOR EACH RELAY · NO POTS TO ADJUST · NO NEED FOR VOLT METER FOR SETUP · ON BOARD "FIELD SELECTABLE" DIGITAL DISPLAY Made in USA Meets "Buy American" of ARRA 2009 N/C COM N/O N/C COM N/O N/C COM N/O N/C COM N/O SPECIFICATIONS # Relays & Contact Type: Four (4) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Power Status: Green LED On = Power On Relay Status: Red LED On = Relay Activated Heartbeat Status: Right-most decimal point Dimensions: 4.950 x 2.750 x 1.750 Track Mount: MT212-6 Mounting Track Provided Approvals: UL Listed, UL916, C-UL, CE, RoHS Gold Flash: No Override Switch: No Contact Ratings: 15 Amp General Use @ 125 Vac 10 Amp General Use @ 277 Vac 10 Amp Resistive @ 30 Vdc (N/O) 7 Amp Resistive @ 30 Vdc (N/C) 1/2 HP @ 125 Vac 1 HP @ 250 Vac 1/4 HP @ 277 Vac 470 VA Pilot Duty @ 125 Vac 770 VA Pilot Duty @ 250 Vac Power Input: 24 Vac/dc ; 50-60 Hz 200mA max. Notes: · For AC applications, an isolation transformer, to be used solely for the power input, is recommended. · Relay will activate when control signal voltage reaches or exceeds individual relay ON point. Relay will deactivate when control voltage reaches or drops below individual OFF point. · Factory relay ON / OFF voltages: · Relay 1: 3V / 2.8V · Relay 2: 5V / 4.8V · Relay 3: 7V / 6.8V · Relay 4: 9V / 8.8 V · Minimum ON point: 0.5V · Maximum ON point: 9.9V · Minimum OFF point: 0.3V · Relay number will flash 3 times when voltage exceeds setpoint. · Pressing UP or DN button in normal run mode will display the voltage present on Analog Input. · ON/OFF points can be changed at any time, by the user, by entering "Program Mode" · User defined ON/OFF points will be maintained upon power loss. MANUAL ANALOG OVERRIDE SWITCH RIBMNA1D0 2.75 Track Mount Manual Analog Override Switch + Monitor with 24 Vac/dc Power Input Signal + Signal Power Power + Manual Auto 80% 60% 40% 20% + Potentiometer Output + Output Feedback Legend for Selecting Output for Jumpers Top 2 pins covered by jumper Bottom 2 pins covered by jumper Only 1 pin covered by jumper 5 Vdc 10 Vdc 15 Vdc 20 mA Made in USA Meets "Buy American" of ARRA 2009 SPECIFICATIONS Operating Temperature: -30 to 140° F Humidity Range: 5 to 95% (noncondensing) Dimensions: 2.450 x 2.750 x 1.270 Track Mount: 2.750", See MT212 Series on page 142 MT212 Mounting Track Sold Separately Input Voltage: 24 Vac/dc Input Current: 90mA Max. Range/Impedance Override: 0-5 Vdc, 200 Min. 0-10 Vdc, 400 Min. 0-15 Vdc, 1 k Min. 0-20mA dc, 500 Max. Feedback Contact: 2A Max. @ 24 Vac/dc Notes: · Set the jumpers according to your input signal (Analog signal from the controller.) Example: When controlling a damper with 0-10 Vdc, the jumpers need to be in position for the 0-10 Vdc override range. If the LED range does not match your analog scale, ensure the jumpers are set for the proper range. · Feedback contact closed when switch is in Manual position, open when switch is in Auto position. · PROVIDES MANUAL OVERRIDE IF CONTROLLER DOES NOT SUPPORT OVERRIDE CAPABILITY · ALLOWS YOU TO MANUALLY MAKE ADJUSTMENTS TO YOUR END DEVICE REMOTELY INSTEAD OF AT YOUR CONTROL PANEL · SENDS OVERRIDE STATUS BACK TO CONTROLLER VIA FEEDBACK · MULTI-RANGE ANALOG OUTPUT (800) 888-5538 | www.functionaldevices.com 89 Notes RELAYS 90 Functional Devices, Inc. | American Made. American Owned.Adobe InDesign CC 2015 (Macintosh) Adobe PDF Library 15.0