Test Report-BLE

Promaster Electronic LLC WUA1 Wireless CP adaptor 2A6P9-WUA1 2A6P9WUA1 wua1

download (pdf)

WUA1 Wireless Cp Adaptor by Promaster Electronic

PDF preview unavailable. Download the PDF instead.

WUA1-Test-Report-Promaster-Electronic-2a6p9-wua1-ex-2-4
Shenzhen CTA Testing Technology Co., Ltd.
Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China

FCC PART 15 SUBPART C TEST REPORT

FCC PART 15.247

Report Reference No......................: CTA22061000203 FCC ID............................................. : 2A6P9-WUA1
Compiled by ( position+printed name+signature)..: File administrators Kevin Liu
Supervised by ( position+printed name+signature)..: Project Engineer Kevin Liu
Approved by ( position+printed name+signature)..: RF Manager Eric Wang

Date of issue.....................................: Jun. 14, 2022

Testing Laboratory Name ..............: Shenzhen CTA Testing Technology Co., Ltd.

Address

............................................ :

Room Fuhai

106, Building 1, Street, Bao'an

Yibaolai District,

Industrial Park, Qiaotou Shenzhen, China

Community,

Applicant's name............................: Promaster Electronic LLC

Address ............................................: 25511 Budde Rd, Ste 1602. Spring, TX, 77380. USA

Test specification ...........................:

Standard ...........................................: FCC Part 15.247
Shenzhen CTA Testing Technology Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

Equipment description...................: Wireless CP adaptor Trade Mark .......................................: Autosky Manufacturer ....................................: Huizhou Funnavi Electronics Co., Ltd Model/Type reference.......................: WUA-1 Listed Models ..................................: N/A

Modulation .......................................: GFSK

Frequency.......................................... From 2402MHz to 2480MHz

Ratings .............................................: DC 5V From external circuit

Result................................................: PASS

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203
TEST REPORT

Page 2 of 31

Equipment under Test : Wireless CP adaptor

Model /Type

: WUA-1

Listed Models

: N/A

Applicant

: Promaster Electronic LLC

Address

: 25511 Budde Rd, Ste 1602. Spring, TX, 77380. USA

Manufacturer

: Huizhou Funnavi Electronics Co., Ltd

Address

:

3rd floor, No.:25 Xiangda road Xiao Jin kou street, Huicheng district,

Huizhou city, China

Test Result:

PASS

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory.

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 3 of 31

Contents

1

TEST STANDARDS ................................................................. 4

2

SUMMARY ............................................................................ 5

2.1

General Remarks

5

2.2

Product Description

5

2.3

Equipment Under Test

5

2.4

Short description of the Equipment under Test (EUT)

5

2.5

EUT operation mode

6

2.6

Block Diagram of Test Setup

6

2.7

Related Submittal(s) / Grant (s)

6

2.8

Modifications

6

3

TEST ENVIRONMENT .............................................................. 7

3.1

Address of the test laboratory

7

3.2

Test Facility

7

3.3

Environmental conditions

7

3.4

Summary of measurement results

8

3.5

Statement of the measurement uncertainty

8

3.6

Equipments Used during the Test

9

4

TEST CONDITIONS AND RESULTS........................................... 10

4.1

AC Power Conducted Emission

10

4.2

Radiated Emissions and Band Edge

13

4.3

Maximum Peak Output Power

20

4.4

Power Spectral Density

21

4.5

6dB Bandwidth

23

4.6

Out-of-band Emissions

25

4.7

Antenna Requirement

29

5

TEST SETUP PHOTOS OF THE EUT ......................................... 30

6

PHOTOS OF THE EUT ........................................................... 31

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 4 of 31

1 TEST STANDARDS
The tests were performed according to following standards:
FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz. ANSI C63.10-2013: American National Standard for Testing Unlicensed Wireless Devices KDB558074 D01 V05r02: Guidance for Performing Compliance Measurements on Digital Transmission Systems (DTS) Operating Under §15.247

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 5 of 31

2 SUMMARY

2.1 General Remarks
Date of receipt of test sample

: Jun. 01, 2022

Testing commenced on

: Jun. 01, 2022

Testing concluded on
2.2 Product Description

: Jun. 14, 2022

Product Description:

Wireless CP adaptor

Model/Type reference:

WUA-1

Power supply:

DC 5.0V From external circuit

PC information (Auxiliary test supplied by testing Lab
PC Adapter information (Auxiliary test supplied by testing Lab
Hardware version:

Model: TP00083A Input:AC 100-240V 50/60Hz Output:DC 20V 2.5A
Model: ADLX45NCC3A Input:AC 100-240V 50/60Hz Output:DC 20V 2.5A
V1.0

Software version: Testing sample ID Bluetooth BLE

V1.0
CTA220610002-1# (Engineer sample) CTA220610002-2# (Normal sample)

Supported type:

Bluetooth low Energy

Modulation:

GFSK

Operation frequency:

2402MHz to 2480MHz

Channel number:

40

Channel separation:

2 MHz

Antenna type:

PCB antenna

Antenna gain:

0.00 dBi

2.3 Equipment Under Test Power supply system utilised

Power supply voltage

:  230V / 50 Hz

 120V / 60Hz

 12 V DC

 24 V DC

 Other (specified in blank below)

DC 5V From external circuit
2.4 Short description of the Equipment under Test (EUT)
This is a Wireless CP adaptor . For more details, refer to the user's manual of the EUT.

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 6 of 31

2.5 EUT operation mode

The Applicant provides communication tools software(Engineer mode) to control the EUT for staying in

continuous transmitting (Duty Cycle more than 98%) and receiving mode for testing .There are 40 channels

provided to the EUT and Channel 00/19/39 were selected to test.

Operation Frequency Channel 00 01 02

Frequency (MHz) 2402 2404 2406

... ... ... ...

19

2440

37 38 39
2.6 Block Diagram of Test Setup

2476 2478 2480

EUT

DC 5.0V from PC

2.7 Related Submittal(s) / Grant (s)
This submittal(s) (test report) is intended for the device filing to comply with Section 15.247 of the FCC Part 15, Subpart C Rules.
2.8 Modifications
No modifications were implemented to meet testing criteria.

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 7 of 31

3 TEST ENVIRONMENT

3.1 Address of the test laboratory
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China

3.2 Test Facility

The test facility is recognized, certified, or accredited by the following organizations: FCC-Registration No.: 517856 Designation Number: CN1318
Shenzhen CTA Testing Technology Co., Ltd. has been listed on the US Federal Communications Commission list of test facilities recognized to perform electromagnetic emissions measurements.
A2LA-Lab Cert. No.: 6534.01
Shenzhen CTA Testing Technology Co., Ltd. has been listed by American Association for Laboratory Accreditation to perform electromagnetic emission measurement.
The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.10 and CISPR 16-1-4:2010.

3.3 Environmental conditions

During the measurement the environmental conditions were within the listed ranges:

Radiated Emission:

Temperature:

23 °C

Humidity:

44 %

Atmospheric pressure:

950-1050mbar

AC Main Conducted testing Temperature:

24 °C

Humidity:

47 %

Atmospheric pressure:

950-1050mbar

Conducted testing Temperature:

24 °C

Humidity:

46 %

Atmospheric pressure:

950-1050mbar

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 8 of 31

3.4 Summary of measurement results

Test Specification
clause

Test case

Test Mode

Test Channel

§15.247(e)

Power spectral density

BLE 1Mpbs

Lowest Middle Highest

§15.247(a)(2)

Spectrum bandwidth

BLE 1Mpbs

Lowest Middle

­ 6 dB bandwidth

Highest

§15.247(b)(3)

Maximum output Peak power

BLE 1Mpbs

Lowest Middle Highest

§15.247(d)

Band edge compliance conducted

BLE 1Mpbs

Lowest Highest

§15.205

Band edge compliance
radiated

BLE 1Mpbs

Lowest Highest

§15.247(d)

TX spurious emissions

BLE 1Mpbs

Lowest Middle

conducted

Highest

§15.247(d)

TX spurious emissions

BLE 1Mpbs

Lowest Middle

radiated

Highest

TX spurious

§15.209(a)

Emissions radiated

BLE 1Mpbs

-/-

Below 1GHz

§15.107(a) §15.207

Conducted Emissions

BLE 1Mpbs

-/-

< 30 MHz

Remark:

1. The measurement uncertainty is not included in the test result.

2. We tested all test mode and recorded worst case in report

Recorded In Report

BLE 1Mpbs
BLE 1Mpbs
BLE 1Mpbs
BLE 1Mpbs

Lowest Middle Highest Lowest Middle Highest Lowest Middle Highest
Lowest Highest

BLE 1Mpbs

Lowest Highest

BLE 1Mpbs
BLE 1Mpbs

Lowest Middle Highest Lowest Middle Highest

BLE

1Mpbs

-/-

BLE

1Mpbs

-/-

Test result complies complies complies complies complies complies complies complies complies

3.5 Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. to TR-100028-01" Electromagnetic compatibility and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part 1" and TR-100028-02 "Electromagnetic compatibility and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part 2 " and is documented in the Shenzhen CTA Testing Technology Co., Ltd. quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

Hereafter the best measurement capability for Shenzhen CTA Testing Technology Co., Ltd. :

Test

Range

Measurement Uncertainty

Notes

Radiated Emission

30~1000MHz

4.06 dB

(1)

Radiated Emission

1~18GHz

5.14 dB

(1)

Radiated Emission

18-40GHz

5.38 dB

(1)

Conducted Disturbance

0.15~30MHz

2.14 dB

(1)

(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%

confidence level using a coverage factor of k=2.

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 9 of 31

3.6 Equipments Used during the Test

Test Equipment
LISN
LISN
EMI Test Receiver
EMI Test Receiver
Spectrum Analyzer Spectrum Analyzer
Vector Signal generator
Analog Signal Generator
Universal Radio Communication Temperature and humidity meter Ultra-Broadband
Antenna Horn Antenna Loop Antenna
Horn Antenna
Amplifier Amplifier Directional coupler High-Pass Filter High-Pass Filter Automated filter
bank Power Sensor
Amplifier

Manufacturer
R&S
R&S
R&S
R&S Agilent
R&S Agilent
R&S
CMW500
Chigo
Schwarzbeck Schwarzbeck
Zhinan Beijing Hangwei
Dayang Schwarzbeck Taiwan chengyi
NARDA XingBo XingBo Tonscend Agilent Schwarzbeck

Model No.
ENV216
ENV216
ESPI
ESCI N9020A
FSP N5182A
SML03
R&S
ZG-7020
VULB9163 BBHA 9120D
ZN30900C OBH100400
BBV 9745 EMC051845B
4226-10 XBLBQ-GTA18 XBLBQ-GTA27
JS0806-F U2021XA BBV9719

Equipment No.
CTA-308
CTA-314
CTA-307
CTA-306 CTA-301 CTA-337 CTA-305
CTA-304
CTA-302
CTA-326
CTA-310 CTA-309 CTA-311 CTA-336 CTA-312 CTA-313 CTA-303 CTA-402 CTA-403 CTA-404 CTA-405 CTA-406

Calibration Date
2021/08/06

Calibration Due Date
2022/08/05

2021/08/06 2022/08/05

2021/08/06 2022/08/05

2021/08/06 2021/08/06 2021/08/06 2021/08/06

2022/08/05 2022/08/05 2022/08/05 2022/08/05

2021/08/06 2022/08/05

2021/08/06 2022/08/05

2021/08/06 2022/08/05

2021/08/07 2021/08/07 2021/08/07
2021/08/06
2021/08/06 2021/08/06 2021/08/06 2021/08/06 2021/08/06
2021/08/06
2021/08/06 2021/08/06

2022/08/06 2022/08/06 2022/08/06
2022/08/05
2022/08/05 2022/08/05 2022/08/05 2022/08/05 2022/08/05
2022/08/05
2022/08/05 2022/08/05

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 10 of 31

4 TEST CONDITIONS AND RESULTS
4.1 AC Power Conducted Emission

TEST CONFIGURATION

Vert. reference plane

EMI receiver

EUT

LISN

Reference ground plane

TEST PROCEDURE

1 The equipment was set up as per the test configuration to simulate typical actual usage per the user's manual. The EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is placed on the ground plane as per ANSI C63.10-2013. 2 Support equipment, if needed, was placed as per ANSI C63.10-2013 3 All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10-2013 4 The EUT received power from adapter, the adapter received AC120V/60Hz and AC 240V/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied power source and was grounded to the ground plane. 5 All support equipments received AC power from a second LISN, if any. 6 The EUT test program was started. Emissions were measured on each current carrying line of the EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT.The LISN has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver. 7 Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes. 8 During the above scans, the emissions were maximized by cable manipulation.
AC Power Conducted Emission Limit

For intentional device, according to § 15.207(a) AC Power Conducted Emission Limits is as following

Frequency range (MHz) 0.15-0.5

Quasi-peak 66 to 56*

Limit (dBuV)

Average 56 to 46*

0.5-5

56

46

5-30

60

50

* Decreases with the logarithm of the frequency.

TEST RESULTS Remark:
1. BLE 1Mpbs was tested at Low, Middle, and High channel; only the worst result of BLE 1Mpbs High channel was reported as below:

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 11 of 31

2. Both 120 VAC, 50/60 Hz and 240 VAC, 50/60 Hz power supply have been tested, only the worst result of 120 VAC, 60 Hz was reported as below:

Power supply:

DC 5.0V from PC AC 120V/60Hz

Polarization

L

Note:1).QP Value (dBµV)= QP Reading (dBµV)+ Factor (dB) 2). Factor (dB)=insertion loss of LISN (dB) + Cable loss (dB) 3). QPMargin(dB) = QP Limit (dBµV) - QP Value (dBµV) 4). AVMargin(dB) = AV Limit (dBµV) - AV Value (dBµV)
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Power supply:

DC 5.0V from PC AC 120V/60Hz

Page 12 of 31

Polarization

N

Note:1).QP Value (dBµV)= QP Reading (dBµV)+ Factor (dB) 2). Factor (dB)=insertion loss of LISN (dB) + Cable loss (dB) 3). QPMargin(dB) = QP Limit (dBµV) - QP Value (dBµV) 4). AVMargin(dB) = AV Limit (dBµV) - AV Value (dBµV)
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

4.2 Radiated Emissions and Band Edge
TEST CONFIGURATION Frequency range 9 KHz ­ 30MHz

Turntable EUT

Loop antenna 3m

0.8 m

Ground Plane Frequency range 30MHz ­ 1000MHz

Coaxial Cable

Page 13 of 31
Test Receiver

Turntable
Test Receiver

3m

EUT

0.8m

Ground Plane

Frequency range above 1GHz-25GHz

1m to 4m Coaxial Cable

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 14 of 31

TEST PROCEDURE

1. The EUT was placed on a turn table which is 0.8m above ground plane when testing

frequency range 9 KHz ­1GHz;the EUT was placed on a turn table which is 1.5m above

ground plane when testing frequency range 1GHz ­ 25GHz.

2. Maximum procedure was performed by raising the receiving antenna from 1m to 4m and rotating the turn table from 0 to 360 to acquire the highest emissions from EUT.

3. And also, each emission was to be maximized by changing the polarization of receiving

antenna both horizontal and vertical.

4. Repeat above procedures until all frequency measurements have been completed.

5. The EUT minimum operation frequency was 32.768KHz and maximum operation

frequency was 2480MHz.so radiated emission test frequency band from 9KHz to 25GHz.

6. The distance between test antenna and EUT as following table states:

Test Frequency range

Test Antenna Type

Test Distance

9KHz-30MHz

Active Loop Antenna

3

30MHz-1GHz

Ultra-Broadband Antenna

3

1GHz-18GHz

Double Ridged Horn Antenna 3

18GHz-25GHz

Horn Anternna

1

7. Setting test receiver/spectrum as following table states:

Test Frequency range

Test Receiver/Spectrum Setting

Detector

9KHz-150KHz

RBW=200Hz/VBW=3KHz,Sweep time=Auto

QP

150KHz-30MHz

RBW=9KHz/VBW=100KHz,Sweep time=Auto

QP

30MHz-1GHz

RBW=120KHz/VBW=1000KHz,Sweep time=Auto

QP

Peak Value: RBW=1MHz/VBW=3MHz,

1GHz-40GHz

Sweep time=Auto Average Value: RBW=1MHz/VBW=10Hz,

Peak

Sweep time=Auto

Field Strength Calculation

The field strength is calculated by adding the Antenna Factor and Cable Factor and subtracting the Amplifier Gain and Duty Cycle Correction Factor(if any) from the measured reading. The basic equation with a sample calculation is as follows:

FS = RA + AF + CL - AG

Where FS = Field Strength RA = Reading Amplitude AF = Antenna Factor

CL = Cable Attenuation Factor (Cable Loss) AG = Amplifier Gain

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 15 of 31

Transd=AF +CL-AG

RADIATION LIMIT

For intentional device, according to § 15.209(a), the general requirement of field strength of radiated emission from intentional radiators at a distance of 3 meters shall not exceed the following table. According to § 15.247(d), in any 100kHz bandwidth outside the frequency band in which the EUT is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the100kHz bandwidth within the band that contains the highest level of desired power.

The pre-test have done for the EUT in three axes and found the worst emission at position shown in test setup photos.

Frequency (MHz)
0.009-0.49 0.49-1.705 1.705-30
30-88 88-216 216-960 Above 960

Distance (Meters)
3 3 3 3 3 3 3

Radiated (dBV/m)
20log(2400/F(KHz))+40log(300/3) 20log(24000/F(KHz))+ 40log(30/3)
20log(30)+ 40log(30/3) 40.0 43.5 46.0 54.0

Radiated (V/m)
2400/F(KHz) 24000/F(KHz)
30 100 150 200 500

TEST RESULTS Remark: 1. This test was performed with EUT in X, Y, Z position and the worse case was found when EUT in X
position. 2. BLE 1Mpbs were tested at Low, Middle, and High channel and recorded worst mode at BLE 1Mpbs. 3. Radiated emission test from 9 KHz to 10th harmonic of fundamental was verified, and no emission found
except system noise floor in 9 KHz to 30MHz and not recorded in this report.
For 30MHz-1GHz

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Horizontal

Page 16 of 31

Note:1).Level (dBµV/m)= Reading (dBµV)+ Factor (dB/m) 2). Factor(dB/m)=Antenna Factor (dB/m) + Cable loss (dB) - Pre Amplifier gain (dB) 3). Margin(dB) = Limit (dBµV/m) - Level (dBµV/m)

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Vertical

Page 17 of 31

Note:1).Level (dBµV/m)= Reading (dBµV)+ Factor (dB/m) 2). Factor(dB/m)=Antenna Factor (dB/m) + Cable loss (dB) - Pre Amplifier gain (dB) 3). Margin(dB) = Limit (dBµV/m) - Level (dBµV/m)

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 18 of 31

For 1GHz to 25GHz

Frequency(MHz):

Frequency (MHz)

Emission Level
(dBuV/m)

4804.00 4804.00 7206.00 7206.00

60.55 PK 44.79 AV 53.58 PK 42.64 AV

GFSK (above 1GHz)

2402

Polarity:

Limit (dBuV/m)

Margin (dB)

Raw Value (dBuV)

Antenna Factor (dB/m)

74

13.45

64.82

32.33

54

9.21

49.06

32.33

74

20.42

54.10

36.6

54

11.36

43.16

36.6

HORIZONTAL

Cable Factor (dB)

Pre- Correction

amplifier Factor

(dB)

(dB/m)

5.12

41.72

-4.27

5.12

(4d1B.7)e2-

-4.27

6.49 am43p.l6if1ier -0.52

6.49

F4a3c.6to1r

-0.52

Frequency(MHz):

Frequency (MHz)

Emission Level
(dBuV/m)

4804.00 4804.00 7206.00

58.19 PK 42.43 AV 51.22 PK

7206.00

40.28 AV

2402

Limit (dBuV/m)
74 54 74 54

Margin (dB)
15.81 11.57 22.78 13.72

Polarity:

Raw Value (dBuV)

Antenna Factor (dB/m)

62.46

32.33

46.70

32.33

51.74

36.6

40.80

36.6

Cable Factor (dB) 5.12 5.12
6.49
6.49

VERTICAL

Pre- Correction

amplifier Factor

(dB)

(dB/m)

41.72 (4d1B.7)e2aFm4a3pc.l6tifo1ier r 43.61

-4.27 -4.27 -0.52 -0.52

Frequency(MHz):

Frequency (MHz)
4880.00 4880.00 7320.00 7320.00

Emission Level
(dBuV/m) 60.22 PK 45.46 AV 53.18 PK 42.83 AV

2440

Limit (dBuV/m)
74 54 74 54

Margin (dB)
13.78 8.54 20.82 11.17

Polarity:

Raw Value (dBuV) 64.10 49.34 53.29 42.94

Antenna Factor (dB/m) 32.6 32.6 36.8 36.8

HORIZONTAL

Cable Factor (dB)

Pre- Correction

amplifier Factor

(dB)

(dB/m)

5.34

41.82

-3.88

5.34

(4d1B.8)e2-

-3.88

6.81 am43p.l7if2ier -0.11

6.81

F4a3c.7to2r

-0.11

Frequency(MHz):

Frequency (MHz)
4880.00 4880.00 7320.00 7320.00

Emission Level
(dBuV/m)
57.86 PK 43.10 AV 50.82 PK 40.47 AV

2440

Limit (dBuV/m)
74 54 74 54

Margin (dB)
16.14 10.90 23.18 13.53

Polarity:

Raw Value (dBuV)
61.74 46.98 50.93 40.58

Antenna Factor (dB/m)
32.6 32.6 36.8 36.8

Cable Factor (dB)
5.34 5.34 6.81 6.81

VERTICAL

Pre- Correction

amplifier Factor

(dB)

(dB/m)

41.82 (4d1B.8)e2am43p.l7if2ier F4a3c.7to2r

-3.88 -3.88 -0.11 -0.11

Frequency(MHz):

Frequency (MHz)

Emission Level
(dBuV/m)

4960.00 4960.00

60.99 PK 44.98 AV

7440.00 7440.00

54.79 PK 43.72 PK

2480

Limit (dBuV/m)
74 54 74 54

Margin (dB)
13.01 9.02 19.21 10.28

Polarity:

Raw Value (dBuV)

Antenna Factor (dB/m)

64.07

32.73

48.06

32.73

54.34 43.27

37.04 37.04

HORIZONTAL

Cable Factor (dB)

Pre- Correction

amplifier Factor

(dB)

(dB/m)

5.66

41.47

-3.08

5.66

(4d1B.4)e7-

-3.08

7.25

aFm4a3pc.l8tifo4ier r

0.45

7.25

43.84

0.45

Frequency(MHz):

Frequency (MHz)

Emission Level
(dBuV/m)

4960.00

58.63 PK

4960.00

42.62 AV

7440.00

52.43 PK

7440.00

41.36 PK

REMARKS:

2480

Limit (dBuV/m)
74 54 74 54

Margin (dB)
15.37 11.38 21.57 12.64

Polarity:

Raw Value (dBuV) 61.71 45.70 51.98 40.91

Antenna Factor (dB/m) 32.73 32.73 37.04 37.04

Cable Factor (dB) 5.66 5.66 7.25 7.25

VERTICAL

Pre- Correction

amplifier Factor

(dB)

(dB/m)

41.47 (4d1B.4)e7am43p.l8if4ier F4a3c.8to4r

-3.08 -3.08 0.45 0.45

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 19 of 31

1. Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m) 2. Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)- Pre-amplifier 3. Margin value = Limit value- Emission level. 4. -- Mean the PK detector measured value is below average limit. 5. The other emission levels were very low against the limit.

Results of Band Edges Test (Radiated)

GFSK

Frequency(MHz):

2402

Polarity:

HORIZONTAL

Frequency (MHz)

Emission Level
(dBuV/m)

Limit (dBuV/m)

Margin (dB)

Raw Value (dBuV)

Antenna Factor (dB/m)

Cable Factor (dB)

Pre- Correction

amplifier Factor

(dB)

(dB/m)

2390.00 2390.00

60.62 PK 43.42 AV

Frequency(MHz):

Frequency (MHz)
2390.00 2390.00

Emission Level
(dBuV/m)
58.26 PK 41.06 AV

Frequency(MHz):

Frequency (MHz)

Emission Level
(dBuV/m)

74

13.38

54

10.58

2402

Limit (dBuV/m)

Margin (dB)

74

15.74

54

12.94

2480

Limit (dBuV/m)

Margin (dB)

71.04 53.84

27.42 27.42

Polarity:

Raw Value (dBuV)

Antenna Factor (dB/m)

68.68 51.48

27.42 27.42

P olarity:

Raw Value (dBuV)

Antenna Factor (dB/m)

4.31 4.31
Cable

42.15 -10.42

(4d2B.1)e5-

-10.42

amplifier

VEFRaTcItCorAL

Pre- Correction

Factor amplifier Factor

(dB)

(dB)

(dB/m)

4.31

42.15 -10.42

4.31

(4d2B.1)e5-

-10.42

HOaRFmIaZpcOltifoNierTr AL

Cable

Pre- Correction

Factor amplifier Factor

(dB)

(dB)

(dB/m)

2483.50 2483.50

59.85 PK 41.89 AV

Frequency(MHz):

Frequency (MHz)

Emission Level
(dBuV/m)

74

14.15

54

12.11

2480

Limit (dBuV/m)

Margin (dB)

69.96

27.7

52.00

27.7

Polarity:

Raw Value (dBuV)

Antenna Factor (dB/m)

4.47 4.47
Cable Factor (dB)

42.28 -10.11

(4d2B.2)e8-

-10.11

VaEFmRapTclItiCfoierArL

Pre- Correction

amplifier Factor

(dB)

(dB/m)

2483.50

57.49 PK

74

16.51

67.60

27.7

4.47

2483.50

39.53 AV

54

14.47

49.64

27.7

4.47

REMARKS:

1. Emission level (dBuV/m) =Raw Value (dBuV)+Correction Factor (dB/m)

2. Correction Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)- Pre-amplifier

3. Margin value = Limit value- Emission level.

4. -- Mean the PK detector measured value is below average limit.

5. The other emission levels were very low against the limit.

42.28 (4d2B.2)e8amplifier
Factor

-10.11 -10.11

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 20 of 31

4.3 Maximum Peak Output Power
Limit The Maximum Peak Output Power Measurement is 30dBm. Test Procedure Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to the power sensor. Test Configuration

EUT

Power Sensor

Test Results Type
GFSK 1Mbps

Channel
00 19 39

Output power (dBm) 0.45
1.03
1.31

Note: 1.The test results including the cable lose.S

Limit (dBm) 30.00

Result Pass

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 21 of 31

4.4 Power Spectral Density
Limit
For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. Test Procedure 1. Use this procedure when the maximum peak conducted output power in the fundamental emission is used
to demonstrate compliance. 2. Set the RBW  3 kHz. 3. Set the VBW  3× RBW. 4. Set the span to 1.5 times the DTS channel bandwidth. 5. Detector = peak. 6. Sweep time = auto couple. 7. Trace mode = max hold. 8. Allow trace to fully stabilize. 9. Use the peak marker function to determine the maximum power level. 10. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat. 11. The resulting peak PSD level must be 8dBm. Test Configuration

EUT

SPECTRUM ANALYZER

Test Results

Type GFSK 1Mbps Test plot as follows:

Channel
00 19 39

Power Spectral Density (dBm/3KHz) -17.66
-16.9 -16.6

Limit (dBm/3KHz) 8.00

Result Pass

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

BLE GFSK 1Mpbs

Page 22 of 31

CH00

CH19

CH39
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 23 of 31

4.5 6dB Bandwidth
Limit For digital modulation systems, the minimum 6 dB bandwidth shall be at least 500 kHz Test Procedure
The transmitter output was connected to the spectrum analyzer through an attenuator. The bandwidth of the fundamental frequency was measured by spectrum analyzer with 100 KHz RBW and 300 KHz VBW. The 6dB bandwidth is defined as the total spectrum the power of which is higher than peak power minus 6dB.
Test Configuration

EUT

Test Results Type
GFSK 1Mbps Test plot as follows:

Channel
00 19 39

SPECTRUM ANALYZER

6dB Bandwidth (MHz) 0.652 0.660 0.600

Limit (KHz) 500

Result Pass

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

BLE GFSK 1Mpbs

Page 24 of 31

CH00

CH19

CH39
Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 25 of 31

4.6 Out-of-band Emissions
Limit In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF con-ducted or a radiated measurement, pro-vided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter com-plies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not required.
Test Procedure
Connect the transmitter output to spectrum analyzer using a low loss RF cable, and set the spectrum analyzer to RBW=100 kHz, VBW= 300 kHz, peak detector , and max hold. Measurements utilizing these setting are made of the in-band reference level, bandedge and out-of-band emissions.

Test Configuration

EUT

SPECTRUM ANALYZER

Test Results Remark: The measurement frequency range is from 30MHz to the 10th harmonic of the fundamental frequency. The lowest, middle and highest channels are tested to verify the spurious emissions and bandage measurement data.
Test plot as follows:

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203 GFSK 1Mbps (CH00)

Page 26 of 31 GFSK 1Mbps (CH19)

reference

reference

30MHz-1G

30MHz-1G

1G-26.5G

1G-26.5G

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203 GFSK 1Mbps (CH39)

Page 27 of 31

reference
30MHz-1G
1G-26.5G Shenzhen CTA Testing Technology Co., Ltd.
Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203 Band-edge Measurements for RF Conducted Emissions:
BLE GFSK 1Mpbs

Page 28 of 31

Left bandedge

Right bandedge

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 29 of 31

4.7 Antenna Requirement
Standard Applicable
For intentional device, according to FCC 47 CFR Section 15.203:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited
FCC CFR Title 47 Part 15 Subpart C Section 15.247(c) (1) (I):
(i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point operations may employ transmitting antennas with directional gain greater than 6dBi provided the maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6dBi.
Antenna Connected Construction
The maximum gain of antenna was 0.00 dBi.
Remark:The antenna gain is provided by the customer , if the data provided by the customer is not accurate, Shenzhen CTA Testing Technology Co., Ltd. does not assume any responsibility.

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203
5 Test Setup Photos of the EUT

Page 30 of 31

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

Report No.: CTA22061000203

Page 31 of 31

6 Photos of the EUT
Reference to the test report No. CTA22061000201 ********************** End of Report **********************

Shenzhen CTA Testing Technology Co., Ltd. Room 106, Building 1, Yibaolai Industrial Park, Qiaotou Community, Fuhai Street, Bao'an District, Shenzhen, China
Tel:+86-755 2322 5875 E-mail:cta@cta-test.cn Web:http://www.cta-test.cn

