REPORT No.SZ23050338W04
TEST REPORT

APPLICANT

: BLU Products, Inc.

PRODUCT NAME : Smart Phone

MODEL NAME

: C5L MAX

BRAND NAME

: BLU

FCC ID

: YHLBLUC5LMX176

STANDARD(S)

: 47 CFR Part 15 Subpart C

RECEIPT DATE

: 2023-06-29

TEST DATE

: 2023-07-04 to 2023-07-26

ISSUE DATE

: 2023-08-04

Edited by:

Peng Mi (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 1 of 111

REPORT No.SZ23050338W04
DIRECTORY
1. Summary of Test Result ················································································ 4 1.1. Testing Applied Standards ·········································································· 5 1.2. Test Equipment List ··················································································· 6 1.3. Measurement Uncertainty ··········································································· 8 1.4. Testing Laboratory····················································································· 8 2. General Description ····················································································· 9 2.1. Information of Applicant and Manufacturer ··················································· 9 2.2. Information of EUT····················································································· 9 2.3. Channel List of EUT ·················································································· 11 2.4. Test Configuration of EUT··········································································12 2.5. Test Conditions ························································································12 2.6. Test Setup Layout Diagram ········································································ 12 3. Test Results ·······························································································15 3.1. Antenna Requirement ···············································································15 3.2. Hopping Mechanism ················································································· 15 3.3. Number of Hopping Frequency···································································16 3.4. Duty Cycle of Test Signal ··········································································· 17 3.5. Maximum Peak Conducted Output Power ···················································· 18 3.6. Maximum Average Conducted Output Power ···············································19 3.7. 20 dB Bandwidth ······················································································ 20 3.8. Carried Frequency Separation ····································································21 3.9. Time of Occupancy (Dwell time) ·································································22 3.10. Conducted Spurious Emissions and Band Edge ··········································· 23 3.11. Conducted Emission·················································································24 3.12. Restricted Frequency Bands ······································································ 25 3.13. Radiated Emission····················································································26

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 2 of 111

REPORT No.SZ23050338W04 Annex A Test Data and Result ··········································································28

Version 1.0

Change History Date 2023-08-04

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 3 of 111

1. Summary of Test Result

REPORT No.SZ23050338W04

No. Section Description

1 15.203

2

15.247(a) 15.247(h)

3 15.247(a)

4

ANSI C63.10

5 15.247(b)

6 15.247(b) 7 15.247(a) 8 15.247(a) 9 15.247(a) 10 15.247(d) 11 15.207 12 15.247(d) 13 15.209,

Antenna Requirement Hopping Mechanism Number of Hopping Frequency
Duty Cycle
Maximum Peak Conducted Output Power Maximum Average Conducted Output Power 20dB Bandwidth Carrier Frequency Separation Time of Occupancy (Dwell time) Conducted Spurious Emission Conducted Emission Restricted Frequency Bands Radiated

Test Date N/A N/A
Jul. 11, 2023 Jul. 04, 2023 Jul. 08, 2023
Jul. 08, 2023 Jul. 04, 2023 Jul. 11, 2023 Jul. 11, 2023 Jul. 04, 2023 Jul. 10, 2023 Jul. 24, 2023 Jul. 24, 2023

Test Engineer
N/A

Result

Method Determination
/Remark

PASS No deviation

N/A

PASS No deviation

Zhong Yanshan
Zhong Yanshan
Zhong Yanshan

PASS PASS PASS

No deviation No deviation No deviation

Zhong Yanshan

PASS

Zhong Yanshan
Zhong Yanshan

PASS PASS

Zhong Yanshan

PASS

Zhong Yanshan

PASS

Fan Zehang PASS

No deviation No deviation No deviation No deviation No deviation No deviation

Gao Jianrou PASS Gao Jianrou PASS

No deviation No deviation

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 4 of 111

REPORT No.SZ23050338W04
15.247(d) Emission Note 1: The tests were performed according to the method of measurements prescribed in ANSI C63.10-2013, KDB558074 D01 v05r02 and DA 00-075. Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 3: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals.
1.1. Testing Applied Standards
According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:  47 CFR Part 15 Subpart C Radio Frequency Devices

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 5 of 111

1.2. Test Equipment List

REPORT No.SZ23050338W04

1.2.1 Conducted Test Equipments

Equipment Name Serial No.

EXA Signal Analzyer

MY53470836

RF Cable (30MHz-26GHz)

CB01

Coaxial Cable

CB02

SMA Connector

CN01

Type N9010A
RF01 RF02 RF03

Manufacturer Agilent

Cal. Date 2023.02.27

Morlab

N/A

Morlab

N/A

HUBER-SUHNER

N/A

Due Date 2024.02.26
N/A N/A N/A

1.2.2 Conducted Emission Test Equipments

Equipment Name Serial No.

Type

Receiver

MY56400093 N9038A

LISN
Pulse Limiter (10dB)
RF Coaxial Cable (DC-100MHz)

8127449
VTSD 9561 F-B #206
BNC

NSLK 8127 VTSD 9561-F
MRE04

Manufacturer KEYSIGHT

Cal. Date Due Date 2023.02.09 2024.02.08

Schwarzbeck 2023.02.21 2024.02.20

Schwarzbeck 2023.06.27 2024.06.26

Qualwave

N/A

N/A

1.2.3 List of Software Used Description Test System
Morlab EMCR V1.2 TS+ -[JS32-CE]

Manufacturer MaiWei Morlab Tonscend

Software Version 2.0.0.0 V1.0 V2.5.0.0

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 6 of 111

REPORT No.SZ23050338W04

1.2.4 Radiated Test Equipments

Equipment Name

Serial No.

Receiver

MY54130016

Test Antenna Bi-Log

9163-519

Test Antenna Loop

1519-022

Test Antenna ­ Horn

01774

Test Antenna ­ BBHA9170

Horn

#773

Preamplifier (10MHz-6GHz)

46732

Preamplifier (2GHz-18GHz)

61171/61172

Preamplifier (18GHz-40GHz)

DS77209

Type N9038A VULB 9163
FMZB1519
BBHA 9120D
BBHA9170 S10M100L38
02 S020180L32
03 DCLNA0118-
40C-S

RF Coaxial Cable (DC-18GHz)

MRE001

PE330

RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-18GHz)
Notch Filter
Anechoic Chamber

MRE002 MRE003 22290045 22290046 22120181
N/A N/A

CLU18
CLU18
QA360-40-K K-0.5
QA360-40-K KF-2
QA500-18-N N-5
WRCG-24002483.5-60SS
9m*6m*6m

Manufacturer Agilent
Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP.
Decentest
Pasternack
Pasternack Pasternack Qualwave Qualwave Qualwave Wainwright
CRT

Cal. Date 2023.06.21 2022.05.25 2022.02.11 2022.07.13 2022.07.14 2023.06.27 2023.06.27 2023.07.04
2023.06.27
2023.06.27 2023.06.27 2023.06.27 2023.06.27 2023.06.27
N/A 2022.05.10

Due Date 2024.06.20 2025.05.24 2025.02.10 2025.07.12 2025.07.13 2024.06.26 2024.06.26 2024.04.03
2024.06.26
2024.06.26 2024.06.26 2024.06.26 2024.06.26 2024.06.26
N/A 2025.05.09

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 7 of 111

1.3. Measurement Uncertainty

REPORT No.SZ23050338W04

Test Items Number of Hopping Frequency Peak Output Power Bandwidth Carrier Frequency Separation Time of Occupancy (Dwell time) Conducted Spurious Emission Restricted Frequency Bands Radiated Emission Conducted Emission
1.4. Testing Laboratory

Uncertainty ±5% ±2.22dB ±5% ±5% ±5% ±2.77dB ±5% ±2.95dB ±2.44dB

Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Confidence levels of 95%

Laboratory Name
Laboratory Address
Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192
226174

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 8 of 111

2. General Description

REPORT No.SZ23050338W04

2.1. Information of Applicant and Manufacturer

Applicant Applicant Address Manufacturer Manufacturer Address

BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA BLU Products, Inc. 8600 NW 36th Street, Suite #200 Doral, FL 33166, USA

2.2. Information of EUT

Product Name: Sample No.: Hardware Version: Software Version: Equipment Type: Bluetooth Version: Modulation Type: Operating Frequency Range: Antenna Type: Antenna Gain:
Accessory Information:

Smart Phone

1#

YK507-MB-V1.0

BLU_C0176_V13.0.G.02.00_GENERIC_26-06-2023_2000

Bluetooth classic

5.0

FHSS (GFSK(1Mbps), /4-DQPSK(EDR 2Mbps),

8-DPSK(EDR 3Mbps))

2402MHz-2480MHz

PIFA Antenna

-0.62dBi

Battery

Brand Name: BLU

Model No.:

C775444200L

Serial No.:

N/A

Capacity:

2000mAh

Rated Voltage: 3.8V

Charge Limit: 4.35V

Manufacturer: Shenzhen Aerospace Electronic Co.,Ltd.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 9 of 111

REPORT No.SZ23050338W04

AC Adapter

Brand Name: BLU

Model No.:

US-NB-1005

Accessory Information:

Serial No.: Rated Output:

N/A 5V 1000mA

Rated Input:

100-240V 50/60Hz, 0.3A

Manufacturer:

SHENZHEN NANBANG ELECTRONICS CO., LTD

Note 1: We use the dedicated software to control the EUT continuous transmission.

Note 2: For a more detailed description, please refer to Specification or User's Manual supplied by

the applicant and/or manufacturer.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 10 of 111

2.3. Channel List of EUT

REPORT No.SZ23050338W04

Channel

Frequency (MHz)

Channel

Frequency (MHz)

Channel

Frequency (MHz)

Channel

Frequency (MHz)

0

2402

20

2422

40

2442

60

2462

1

2403

21

2423

41

2443

61

2463

2

2404

22

2424

42

2444

62

2464

3

2405

23

2425

43

2445

63

2465

4

2406

24

2426

44

2446

64

2466

5

2407

25

2427

45

2447

65

2467

6

2408

26

2428

46

2448

66

2468

7

2409

27

2429

47

2449

67

2469

8

2410

28

2430

48

2450

68

2470

9

2411

29

2431

49

2451

69

2471

10

2412

30

2432

50

2452

70

2472

11

2413

31

2433

51

2453

71

2473

12

2414

32

2434

52

2454

72

2474

13

2415

33

2435

53

2455

73

2475

14

2416

34

2436

54

2456

74

2476

15

2417

35

2437

55

2457

75

2477

16

2418

36

2438

56

2458

76

2478

17

2419

37

2439

57

2459

77

2479

18

2420

38

2440

58

2460

78

2480

19

2421

39

2441

59

2461

Note 1: The black bold channels were selected for test.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 11 of 111

2.4. Test Configuration of EUT

REPORT No.SZ23050338W04

Test mode is used to control the EUT under the maximum power level during test.
2.5. Test Conditions

Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa)

15-35 30-60 86-106

2.6. Test Setup Layout Diagram

2.6.1.Conducted Measurement

2.6.2.Conducted Emission Measurement

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 12 of 111

2.6.3.Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz

REPORT No.SZ23050338W04

2) For radiated emissions from 30MHz to1GHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 13 of 111

3) For radiated emissions above 1GHz

REPORT No.SZ23050338W04

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 14 of 111

3. Test Results

REPORT No.SZ23050338W04

3.1. Antenna Requirement

3.1.1.Requirement

According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section.

3.1.2.Test Result Inside of the EUT has a PIFA antenna coupled with the metal shrapnel. Please refer to the EUT photos.
3.2. Hopping Mechanism

3.2.1.Requirement
According to FCC section 15.247(a)(1), a frequency hopping spread spectrum system shall hop to channel frequencies that are selected at the system hopping rate from a pseudo randomly ordered list of hopping frequencies. Each frequency must be used equally on the average by each transmitter. The system receivers shall have input bandwidths that match the hopping channel bandwidths of their corresponding transmitters and shall shift frequencies in synchronization with the transmitted signals. According to FCC section 15.247(h), the incorporation of intelligence within a frequency hopping spread spectrum system that permits the system to recognize other users within the spectrum band so that it individually and independently chooses and adapts its hop sets to avoid hopping on occupied channels is permitted. The coordination of frequency hopping systems in any other manner for the express purpose of avoiding the simultaneous occupancy of individual hopping frequencies by multiple transmitters is not permitted.

3.2.2.Test Result
The hopping mechanism of the EUT is in compliance with the document "Bluetooth core specification v5.1".

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 15 of 111

3.3. Number of Hopping Frequency

REPORT No.SZ23050338W04

3.3.1.Requirement
According to FCC section 15.247(a)(1)(iii), frequency hopping systems operating in the 2400MHz to 2483.5MHz bands shall use at least 15 hopping frequencies.

3.3.2.Test Procedures
The EUT must have its hopping function enabled. Use the following spectrum analyzer settings: Span = the frequency band of operation RBW: To identify clearly the individual channels, set the RBW to less than 30% of the channel spacing or the 20 dB bandwidth, whichever is smaller. VBW  RBW Sweep = auto Detector function = peak Trace = max hold Allow the trace to stabilize

3.3.3.Test Setup Layout Refer to chapter 2.6.1 in this report.

3.3.4.Test Result Refer to Annex A.1 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 16 of 111

3.4. Duty Cycle of Test Signal

REPORT No.SZ23050338W04

3.4.1.Requirement
Preferably, all measurements of maximum conducted (average) output power will be performed with the EUT transmitting continuously (i.e., with a duty cycle of greater than or equal to 98%).When continuous operation cannot be realized, then the use of sweep triggering/signal gating techniques can be used to ensure that measurements are made only during transmissions at the maximum power control level. Such sweep triggering/signal gating techniques will require knowledge of the minimum transmission duration(T) over which the transmitter is on and is transmitting at its maximum power control level for the tested mode of operation. Sweep triggering/signal gating techniques can then be used if the measurement/sweep time of the analyzer can be set such that it does not exceed T at any time that data are being acquired (i.e.,no transmitter OFF-time is to be considered). When continuous transmission cannot be achieved and sweep triggering/signal gating cannot be implemented, alternative procedures are provided that can be used to measure the average power; however, they will require an additional measurement of the transmitter duty cycle (D). Within this sub clause, the duty cycle refers to the fraction of time over which the transmitter is ON and is transmitting at its maximum power control level. The duty cycle is considered to be constant if variations are less than ±2%; otherwise, the duty cycle is considered to be non constant.

3.4.2.Test Result Refer to Annex A.2 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 17 of 111

REPORT No.SZ23050338W04
3.5. Maximum Peak Conducted Output Power
3.5.1.Requirement According to FCC section 15.247(b)(1), for frequency hopping systems that operates in the 2400MHz to 2483.5MHz band employing at least 75 hopping channels, the maximum peak output power of the intentional radiator shall not exceed 1Watt. For all other frequency hopping systems in the 2400MHz to 2483.5MHz band, it is 0.125Watts.
3.5.2.Test Procedures KDB 558074 Section 8.3.1 was used in order to prove compliance.
3.5.3.Test Setup Layout Refer to chapter 2.6.1 in this report.
3.5.4.Test Result Refer to Annex A.3 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 18 of 111

REPORT No.SZ23050338W04
3.6. Maximum Average Conducted Output Power
3.6.1.Requirement According to FCC section 15.247(b)(1), for frequency hopping systems that operates in the 2400MHz to 2483.5MHz band employing at least 75 hopping channels, the maximum peak output power of the intentional radiator shall not exceed 1Watt. For all other frequency hopping systems in the 2400MHz to 2483.5MHz band, it is 0.125Watts.
3.6.2.Test Procedures KDB 558074 Section 8.3.2 was used in order to prove compliance.
3.6.3.Test Setup Layout Refer to chapter 2.6.1 in this report.
3.6.4.Test Result Refer to Annex A.4 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 19 of 111

3.7. 20 dB Bandwidth

REPORT No.SZ23050338W04

3.7.1.Requirement
According to FCC section 15.247(a)(1), the 20 dB bandwidth is known as the 99% emission bandwidth, or 20 dB bandwidth (10*log1% = 20 dB) taking the total RF output power.

3.7.1.Test Procedures
Use the following spectrum analyzer settings: Span = between 2 to 5 times the OBW, centered on the test channel RBW= 1% to 5% of the OBW VBW  3 x RBW Sweep = auto Detector function = peak Trace = max hold

3.7.2.Test Setup Layout

Refer to chapter 2.6.1 in this report.

3.7.3.Test Result Refer to Annex A.5 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 20 of 111

3.8. Carried Frequency Separation

REPORT No.SZ23050338W04

3.8.1.Requirement
According to FCC section 15.247(a)(1), frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25kHz or two-thirds of the 20dB bandwidth of the hopping channel, whichever is greater.

3.8.2.Test Procedures
The EUT must have its hopping function enabled. According to DA 00-705, use the following spectrum analyzer settings: Span = wide enough to capture the peaks of two adjacent channels Resolution (or IF) Bandwidth (RBW)  1% of the span Video (or Average) Bandwidth (VBW)  RBW Sweep = auto Detector function = peak Trace = max hold Allow the trace to stabilize. Use the marker-delta function to determine the separation between the peaks of the adjacent channels.

3.8.3.Test Setup Layout Refer to chapter 2.6.1 in this report.

3.8.4.Test Result Refer to Annex A.6 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 21 of 111

3.9. Time of Occupancy (Dwell time)

REPORT No.SZ23050338W04

3.9.1.Requirement
According to FCC section 15.247(a) (1) (iii), frequency hopping systems in the 2400 - 2483.5MHz band shall use at least 15 non-overlapping channels. The average time of occupancy on any channel shall not be greater than 0.4 seconds within a period of 0.4 seconds multiplied by the number of hopping channels employed. Frequency hopping systems may avoid or suppress transmissions on a particular hopping frequency provided that a minimum of 15 channels are used.

3.9.2.Test Procedures
Normal Mode: DH1: Dwell time equal to Pulse time (ms) *(1600 / 2 /79)*31.6 Millisecond DH3: Dwell time equal to Pulse time (ms) * (1600 /4 /79) *31.6 Millisecond DH5: Dwell time equal to Pulse Time (ms)* (1600 / 6 /79) *31.6 Millisecond AFH Mode: DH1: Dwell time equal to Pulse time (ms) *(800 / 2 /20)*(0.4*20) Millisecond DH3: Dwell time equal to Pulse time (ms) * (800 / 4 /20)*(0.4*20) Millisecond DH5: Dwell time equal to Pulse Time (ms)* (800 / 6 /20)*(0.4*20) Millisecond.

3.9.3.Test Setup Layout Refer to chapter 2.6.1 in this report.

3.9.4.Test Result Refer to Annex A.7 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 22 of 111

REPORT No.SZ23050338W04
3.10. Conducted Spurious Emissions and Band Edge
3.10.1.Requirement
According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement.
3.10.2.Test Procedures
Use the following spectrum analyzer settings: Span = wide enough to capture the peak level of the in-band emission and all spurious emissions (e.g., harmonics) from the lowest frequency generated in the EUT up through the 10th harmonic. Typically, several plots are required to cover this entire span. RBW = 100 kHz VBW  RBW Sweep = auto Detector function = peak Trace = max hold Allow the trace to stabilize.
3.10.3.Test Setup Layout
Refer to chapter 2.6.1 in this report.
3.10.4.Test Result
Refer to Annex A.8 and A.9 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 23 of 111

3.11. Conducted Emission

REPORT No.SZ23050338W04

3.11.1.Requirement

According to FCC section 15.207, for an intentional radiator that is designed to be connected to the

public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power

line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following

table, as measured using a 50µH/50 line impedance stabilization network (LISN).

Frequency Range (MHz)

Conducted Limit (dBµV)

Quai-peak

Average

0.15 - 0.50

66 to 56

56 to 46

0.50 - 5

56

46

5 - 30

60

50

Note:

(a) The lower limit shall apply at the band edges.

(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

3.11.2.Test Procedures

The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013.

3.11.3.Test Setup Layout Refer to chapter 2.6.2 in this report.

3.11.4.Test Result Refer to Annex A.10 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 24 of 111

3.12. Restricted Frequency Bands

REPORT No.SZ23050338W04

3.12.1.Requirement
According to FCC section 15.247(d), in any 100kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power, In addition, radiated emissions which fall in the restricted bands, as defined in 15.205(a), must also comply with the radiated emission limits specified in 15.209(a).

3.12.2.Test Procedures
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Span = wide enough to fully capture the emission being measured RBW = 1 MHz for f  1GHz, 100 kHz for f < 1GHz VBW = 3 MHz Sweep = auto Detector function = peak/average Trace = max hold Allow the trace to stabilize

3.12.3.Test Setup Layout

Refer to chapter 2.6.3 in this report.

3.12.4.Test Result Refer to Annex A.11 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 25 of 111

3.13. Radiated Emission

REPORT No.SZ23050338W04

3.13.1.Requirement

According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a).

According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions

from an intentional radiator shall not exceed the field strength levels specified in the following table:

Frequency (MHz)

Field Strength (µV/m)

Measurement Distance (m)

0.009 - 0.490

2400/F(kHz)

300

0.490 - 1.705

24000/F(kHz)

30

1.705 - 30.0

30

30

30 - 88

100

3

88 - 216

150

3

216 - 960

200

3

Above 960

500

3

Note1: For above 1000MHz, the emission limit in this paragraph is based on measurement

instrumentation employing an average detector, measurement using instrumentation with a peak

detector function, corresponding to 20dB above the maximum permitted average limit.

Note2:For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and

74dBuV/m@3m (PK).In addition, radiated emissions which fall in the restricted bands, as defined

in Section 15.205(a), also should comply with the radiated emission limits specified in Section

15.209(a)(above table).

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 26 of 111

REPORT No.SZ23050338W04
3.13.2.Test Procedures
The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode.
For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector.
For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak.
For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements.
The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response.
3.13.3.Test Setup Layout
Refer to chapter 2.6.3 in this report.
3.13.4.Test Result
Refer to Annex A.12 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 27 of 111

REPORT No.SZ23050338W04
Annex A Test Data and Result

A.1. Number of Hopping Frequency

Condition NVNT NVNT NVNT

Mode 1-DH5 2-DH5 3-DH5

Antenna Ant1 Ant1 Ant1

Hopping Number 79 79 79

Limit 15 15 15

Verdict Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 28 of 111

REPORT No.SZ23050338W04
Test Graphs Hopping No. NVNT 1-DH5 2402MHz Ant1
Hopping No. NVNT 2-DH5 2402MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 29 of 111

REPORT No.SZ23050338W04
Hopping No. NVNT 3-DH5 2402MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 30 of 111

REPORT No.SZ23050338W04

A.2. Duty Cycle of Test Signal

Condition Mode Frequency (MHz) Antenna Duty Cycle (%)

NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

1-DH5 1-DH5 1-DH5 2-DH5 2-DH5 2-DH5 3-DH5 3-DH5 3-DH5

2402 2441 2480 2402 2441 2480 2402 2441 2480

Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

76.8 77.07 76.8 76.8 77.01 77.13 77.07 77.13 77.01

Correction Factor (dB) 1.15 1.13 1.15 1.15 1.13 1.13 1.13 1.13 1.13

1/T (kHz)
0.35 0.35 0.35 0.35 0.35 0.34 0.35 0.34 0.35

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 31 of 111

REPORT No.SZ23050338W04
Test Graphs Duty Cycle NVNT 1-DH5 2402MHz Ant1
Duty Cycle NVNT 1-DH5 2441MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 32 of 111

REPORT No.SZ23050338W04
Duty Cycle NVNT 1-DH5 2480MHz Ant1
Duty Cycle NVNT 2-DH5 2402MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 33 of 111

REPORT No.SZ23050338W04
Duty Cycle NVNT 2-DH5 2441MHz Ant1
Duty Cycle NVNT 2-DH5 2480MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 34 of 111

REPORT No.SZ23050338W04
Duty Cycle NVNT 3-DH5 2402MHz Ant1
Duty Cycle NVNT 3-DH5 2441MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 35 of 111

REPORT No.SZ23050338W04
Duty Cycle NVNT 3-DH5 2480MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 36 of 111

REPORT No.SZ23050338W04

A.3. Maximum Peak Conducted Output Power

Condition
NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

Mode
1-DH5 1-DH5 1-DH5 2-DH5 2-DH5 2-DH5 3-DH5 3-DH5 3-DH5

Frequency (MHz)
2402 2441 2480 2402 2441 2480 2402 2441 2480

Antenna
Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Conducted Power (dBm)
8.63 12.91 9.63 8.54 12.91 9.06 8.63 12.84 9.03

Duty Factor
(dB)
0 0 0 0 0 0 0 0 0

Total Conducted
Power (dBm) 8.63 12.91 9.63 8.54 12.91 9.06 8.63 12.84 9.03

Total Conducted
Power (mW) 7.29 19.54 9.18 7.14 19.54 8.05 7.29 19.23
8

Limit Conducted
(dBm)
30 30 30 30 30 30 30 30 30

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 37 of 111

REPORT No.SZ23050338W04
Test Graphs Peak Power NVNT 1-DH5 2402MHz Ant1
Peak Power NVNT 1-DH5 2441MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 38 of 111

REPORT No.SZ23050338W04
Peak Power NVNT 1-DH5 2480MHz Ant1
Peak Power NVNT 2-DH5 2402MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 39 of 111

REPORT No.SZ23050338W04
Peak Power NVNT 2-DH5 2441MHz Ant1
Peak Power NVNT 2-DH5 2480MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 40 of 111

REPORT No.SZ23050338W04
Peak Power NVNT 3-DH5 2402MHz Ant1
Peak Power NVNT 3-DH5 2441MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 41 of 111

REPORT No.SZ23050338W04
Peak Power NVNT 3-DH5 2480MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 42 of 111

REPORT No.SZ23050338W04

A.4. Maximum Average Conducted Output Power

Condition
NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

Mode
1-DH5 1-DH5 1-DH5 2-DH5 2-DH5 2-DH5 3-DH5 3-DH5 3-DH5

Frequency (MHz)
2402 2441 2480 2402 2441 2480 2402 2441 2480

Antenna
Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Conducted Power (dBm)
7.04 11.16 7.95 4.53 9.26 4.89 4.87 9.22 5.01

Duty Factor
(dB)
1.15 1.13 1.15 1.15 1.13 1.13 1.13 1.13 1.13

Total Conducted
Power (dBm) 8.19 12.29
9.1 5.68 10.39 6.02
6 10.35 6.14

Total Conducted
Power (mW) 6.59 16.94 8.13
3.7 10.94
4 3.98 10.84 4.11

Limit Conducted
(dBm)
30 30 30 30 30 30 30 30 30

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 43 of 111

REPORT No.SZ23050338W04
Test Graphs Average Power NVNT 1-DH5 2402MHz Ant1
Average Power NVNT 1-DH5 2441MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 44 of 111

REPORT No.SZ23050338W04
Average Power NVNT 1-DH5 2480MHz Ant1
Average Power NVNT 2-DH5 2402MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 45 of 111

REPORT No.SZ23050338W04
Average Power NVNT 2-DH5 2441MHz Ant1
Average Power NVNT 2-DH5 2480MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 46 of 111

REPORT No.SZ23050338W04
Average Power NVNT 3-DH5 2402MHz Ant1
Average Power NVNT 3-DH5 2441MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 47 of 111

REPORT No.SZ23050338W04
Average Power NVNT 3-DH5 2480MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 48 of 111

A.5. 20 dB Bandwidth

Condition NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

Mode 1-DH5 1-DH5 1-DH5 2-DH5 2-DH5 2-DH5 3-DH5 3-DH5 3-DH5

Frequency (MHz) 2402 2441 2480 2402 2441 2480 2402 2441 2480

Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

REPORT No.SZ23050338W04

-20 dB Bandwidth (MHz) 0.836 0.9 0.843 1.286 1.271 1.279 1.298 1.297 1.295

Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 49 of 111

REPORT No.SZ23050338W04
Test Graphs -20dB Bandwidth NVNT 1-DH5 2402MHz Ant1
-20dB Bandwidth NVNT 1-DH5 2441MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 50 of 111

REPORT No.SZ23050338W04
-20dB Bandwidth NVNT 1-DH5 2480MHz Ant1
-20dB Bandwidth NVNT 2-DH5 2402MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 51 of 111

REPORT No.SZ23050338W04
-20dB Bandwidth NVNT 2-DH5 2441MHz Ant1
-20dB Bandwidth NVNT 2-DH5 2480MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 52 of 111

REPORT No.SZ23050338W04
-20dB Bandwidth NVNT 3-DH5 2402MHz Ant1
-20dB Bandwidth NVNT 3-DH5 2441MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 53 of 111

REPORT No.SZ23050338W04
-20dB Bandwidth NVNT 3-DH5 2480MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 54 of 111

REPORT No.SZ23050338W04

A.6. Carried Frequency Separation

Condition Mode Antenna Hopping Freq1 (MHz) Hopping Freq2 (MHz)

NVNT NVNT NVNT

1-DH5 2-DH5 3-DH5

Ant1 Ant1 Ant1

2401.97 2402.026 2402.156

2402.974 2403.162 2403.156

HFS (MHz) 1.004 1.136
1

Limit (MHz) 0.557 0.857 0.865

Verdict
Pass Pass Pass

Test Graphs CFS NVNT 1-DH5 2402MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 55 of 111

REPORT No.SZ23050338W04
CFS NVNT 2-DH5 2402MHz Ant1
CFS NVNT 3-DH5 2402MHz Ant1

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 56 of 111

REPORT No.SZ23050338W04

A.7. Time of Occupancy (Dwell time)

Condition
NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

Mode
1-DH1 1-DH3 1-DH5 2-DH1 2-DH3 2-DH5 3-DH1 3-DH3 3-DH5

Frequency (MHz) 2402 2402 2402 2402 2402 2402 2402 2402 2402

Antenna
Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Pulse Time (ms) 0.377 1.634 2.882 0.385 1.637 2.885 0.386 1.636 2.886

Total Dwell Time (ms)
118.378 233.662 129.69 120.12 232.454 106.745 119.274 232.312 118.326

Burst Count
314 143 45 312 142 37 309 142 41

Period Time (ms)
31600 31600 31600 31600 31600 31600 31600 31600 31600

Limit (ms) 400 400 400 400 400 400 400 400 400

Verdict
Pass Pass Pass Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 57 of 111

REPORT No.SZ23050338W04
Test Graphs Dwell NVLT 1-DH1 2402MHz Ant1 One Burst
Dwell NVLT 1-DH1 2402MHz Ant1 Accumulated

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 58 of 111

REPORT No.SZ23050338W04
Dwell NVLT 1-DH3 2402MHz Ant1 One Burst
Dwell NVLT 1-DH3 2402MHz Ant1 Accumulated

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 59 of 111

REPORT No.SZ23050338W04
Dwell NVLT 1-DH5 2402MHz Ant1 One Burst
Dwell NVLT 1-DH5 2402MHz Ant1 Accumulated

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 60 of 111

REPORT No.SZ23050338W04
Dwell NVLT 2-DH1 2402MHz Ant1 One Burst
Dwell NVLT 2-DH1 2402MHz Ant1 Accumulated

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 61 of 111

REPORT No.SZ23050338W04
Dwell NVLT 2-DH3 2402MHz Ant1 One Burst
Dwell NVLT 2-DH3 2402MHz Ant1 Accumulated

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 62 of 111

REPORT No.SZ23050338W04
Dwell NVLT 2-DH5 2402MHz Ant1 One Burst
Dwell NVLT 2-DH5 2402MHz Ant1 Accumulated

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 63 of 111

REPORT No.SZ23050338W04
Dwell NVLT 3-DH1 2402MHz Ant1 One Burst
Dwell NVLT 3-DH1 2402MHz Ant1 Accumulated

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 64 of 111

REPORT No.SZ23050338W04
Dwell NVLT 3-DH3 2402MHz Ant1 One Burst
Dwell NVLT 3-DH3 2402MHz Ant1 Accumulated

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 65 of 111

REPORT No.SZ23050338W04
Dwell NVLT 3-DH5 2402MHz Ant1 One Burst
Dwell NVLT 3-DH5 2402MHz Ant1 Accumulated

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 66 of 111

A.8. Conducted Spurious Emissions

Condition NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

Mode 1-DH5 1-DH5 1-DH5 2-DH5 2-DH5 2-DH5 3-DH5 3-DH5 3-DH5

Frequency (MHz) 2402 2441 2480 2402 2441 2480 2402 2441 2480

Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

REPORT No.SZ23050338W04

Max Value (dBc) -55.53 -58.48 -56.37 -53.91 -56.94 -54.65 -54.95 -56.35 -55.63

Limit (dBc) -20 -20 -20 -20 -20 -20 -20 -20 -20

Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 67 of 111

REPORT No.SZ23050338W04
Test Graphs Tx. Spurious NVLT 1-DH5 2402MHz Ant1 Ref
Tx. Spurious NVLT 1-DH5 2402MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 68 of 111

REPORT No.SZ23050338W04
Tx. Spurious NVLT 1-DH5 2441MHz Ant1 Ref
Tx. Spurious NVLT 1-DH5 2441MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 69 of 111

REPORT No.SZ23050338W04
Tx. Spurious NVLT 1-DH5 2480MHz Ant1 Ref
Tx. Spurious NVLT 1-DH5 2480MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 70 of 111

REPORT No.SZ23050338W04
Tx. Spurious NVLT 2-DH5 2402MHz Ant1 Ref
Tx. Spurious NVLT 2-DH5 2402MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 71 of 111

REPORT No.SZ23050338W04
Tx. Spurious NVLT 2-DH5 2441MHz Ant1 Ref
Tx. Spurious NVLT 2-DH5 2441MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 72 of 111

REPORT No.SZ23050338W04
Tx. Spurious NVLT 2-DH5 2480MHz Ant1 Ref
Tx. Spurious NVLT 2-DH5 2480MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 73 of 111

REPORT No.SZ23050338W04
Tx. Spurious NVLT 3-DH5 2402MHz Ant1 Ref
Tx. Spurious NVLT 3-DH5 2402MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 74 of 111

REPORT No.SZ23050338W04
Tx. Spurious NVLT 3-DH5 2441MHz Ant1 Ref
Tx. Spurious NVLT 3-DH5 2441MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 75 of 111

REPORT No.SZ23050338W04
Tx. Spurious NVLT 3-DH5 2480MHz Ant1 Ref
Tx. Spurious NVLT 3-DH5 2480MHz Ant1 Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 76 of 111

REPORT No.SZ23050338W04

A.9. Band Edge

Condition NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT NVNT

Mode 1-DH5 1-DH5 2-DH5 2-DH5 3-DH5 3-DH5 1-DH5 1-DH5 2-DH5 2-DH5 3-DH5 3-DH5

Frequency (MHz) 2402 2480 2402 2480 2402 2480 2402 2480 2402 2480 2402 2480

Antenna Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Hopping Mode No-Hopping No-Hopping No-Hopping No-Hopping No-Hopping No-Hopping Hopping Hopping Hopping Hopping Hopping Hopping

Max Value (dBc) -62.1 -62.9 -49.57 -62.29 -51.42 -59.07 -61.55 -63.79 -57.97 -62.44 -61.36 -61.12

Limit (dBc) -20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20 -20

Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 77 of 111

REPORT No.SZ23050338W04
Test Graphs Band Edge NVLT 1-DH5 2402MHz Ant1 No-Hopping Ref
Band Edge NVLT 1-DH5 2402MHz Ant1 No-Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 78 of 111

REPORT No.SZ23050338W04
Band Edge NVLT 1-DH5 2480MHz Ant1 No-Hopping Ref
Band Edge NVLT 1-DH5 2480MHz Ant1 No-Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 79 of 111

REPORT No.SZ23050338W04
Band Edge NVLT 2-DH5 2402MHz Ant1 No-Hopping Ref
Band Edge NVLT 2-DH5 2402MHz Ant1 No-Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 80 of 111

REPORT No.SZ23050338W04
Band Edge NVLT 2-DH5 2480MHz Ant1 No-Hopping Ref
Band Edge NVLT 2-DH5 2480MHz Ant1 No-Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 81 of 111

REPORT No.SZ23050338W04
Band Edge NVLT 3-DH5 2402MHz Ant1 No-Hopping Ref
Band Edge NVLT 3-DH5 2402MHz Ant1 No-Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 82 of 111

REPORT No.SZ23050338W04
Band Edge NVLT 3-DH5 2480MHz Ant1 No-Hopping Ref
Band Edge NVLT 3-DH5 2480MHz Ant1 No-Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 83 of 111

REPORT No.SZ23050338W04
Test Graphs Band Edge(Hopping) NVLT 1-DH5 2402MHz Ant1 Hopping Ref
Band Edge(Hopping) NVLT 1-DH5 2402MHz Ant1 Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 84 of 111

REPORT No.SZ23050338W04
Band Edge(Hopping) NVLT 1-DH5 2480MHz Ant1 Hopping Ref
Band Edge(Hopping) NVLT 1-DH5 2480MHz Ant1 Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 85 of 111

REPORT No.SZ23050338W04
Band Edge(Hopping) NVLT 2-DH5 2402MHz Ant1 Hopping Ref
Band Edge(Hopping) NVLT 2-DH5 2402MHz Ant1 Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 86 of 111

REPORT No.SZ23050338W04
Band Edge(Hopping) NVLT 2-DH5 2480MHz Ant1 Hopping Ref
Band Edge(Hopping) NVLT 2-DH5 2480MHz Ant1 Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 87 of 111

REPORT No.SZ23050338W04
Band Edge(Hopping) NVLT 3-DH5 2402MHz Ant1 Hopping Ref
Band Edge(Hopping) NVLT 3-DH5 2402MHz Ant1 Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 88 of 111

REPORT No.SZ23050338W04
Band Edge(Hopping) NVLT 3-DH5 2480MHz Ant1 Hopping Ref
Band Edge(Hopping) NVLT 3-DH5 2480MHz Ant1 Hopping Emission

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 89 of 111

REPORT No.SZ23050338W04
A.10. Conducted Emission
The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT+ Adapter +Earphone + BT TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 90 of 111

B. Test Plot:

REPORT No.SZ23050338W04

(L Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.3266

36.78

26.31

2 0.4224

38.37

26.58

3 0.5262

35.10

25.63

4 0.5617

33.32

24.85

5 0.6652

34.07

25.18

6 0.7704

33.85

24.02

Limit (dBµV)

Quai-peak 59.54 57.40 56.00 56.00 56.00 56.00

Average 49.54 47.40 46.00 46.00 46.00 46.00

Power-line Verdict

PASS

PASS

Line

PASS PASS

PASS

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 91 of 111

REPORT No.SZ23050338W04

(N Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.2353

36.62

29.42

2 0.2840

33.35

26.27

3 0.3343

36.80

28.76

4 0.3701

33.57

26.37

5 1.0776

39.16

30.56

6 1.2300

37.62

26.81

Limit (dBµV)

Quai-peak 62.26 60.70 59.34 58.50 56.00 56.00

Average 52.26 50.70 49.34 48.50 46.00 46.00

Power-line Verdict

Neutral

PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 92 of 111

REPORT No.SZ23050338W04

A.11. Restricted Frequency Bands

The lowest and highest channels are tested to verify the Restricted Frequency Bands. The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m
Note: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (vertical) was recorded in this test report.

GFSK Mode

Receiver

Max.

Channel

Frequency (MHz)

Detector

Reading UR

AT (dB)

AFactor (dB@3m)

Emission E

Limit (dBµV/m)

Verdict

PK/ AV (dBµV)

(dBµV/m)

0

2362.19

PK

23.49 6.74

27.20

57.43

74

PASS

0

2386.63

AV

11.34 6.74

27.20

45.28

54

PASS

78

2496.52

PK

23.44 6.74

27.20

57.38

74

PASS

78

2489.86

AV

13.06 6.74

27.20

47.00

54

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 93 of 111

REPORT No.SZ23050338W04
(PEAK, Channel 0, GFSK)

(AVERAGE, Channel 0, GFSK)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 94 of 111

REPORT No.SZ23050338W04
(PEAK, Channel 78, GFSK)

(AVERAGE, Channel 78, GFSK)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 95 of 111

REPORT No.SZ23050338W04

/4-DQPSK Mode

Receiver

Max.

Channel

Frequency Detector (MHz)

Reading UR

AT (dB)

AFactor (dB@3m)

Emission E

Limit (dBµV/m)

Verdict

PK/ AV (dBµV)

(dBµV/m)

0

2351.06

PK

23.34 6.74 27.20

57.28

74

PASS

0

2371.55

AV

10.98 6.74 27.20

44.92

54

PASS

78

2484.29

PK

22.64 6.74 27.20

56.58

74

PASS

78

2483.63

AV

13.20 6.74 27.20

47.14

54

PASS

(PEAK, Channel 0,/4-DQPSK)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 96 of 111

REPORT No.SZ23050338W04
(AVERAGE, Channel 0, /4-DQPSK)

(PEAK, Channel 78, /4-DQPSK)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 97 of 111

REPORT No.SZ23050338W04
(AVERAGE, Channel 78, /4-DQPSK)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 98 of 111

REPORT No.SZ23050338W04

8-DPSK Mode

Channel

Frequency (MHz)

Detector PK/ AV

Receiver Reading
UR (dBµV)

0

2386.74

PK

22.33

AT (dB)
6.74

AFactor (dB@3m)

Max. Emission
E (dBµV/m)

Limit (dBµV/m)

Verdict

27.20

56.27

74

PASS

0

2387.98

AV

11.31

6.74

27.20

45.25

54

PASS

78

2484.64

PK

22.74 6.74

27.20

56.68

74

PASS

78

2483.50

AV

13.00 6.74

27.20

46.94

54

PASS

(PEAK, Channel 0, 8-DPSK)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 99 of 111

REPORT No.SZ23050338W04
(AVERAGE, Channel 0, 8-DPSK)

(PEAK, Channel 78, 8-DPSK)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 100 of 111

REPORT No.SZ23050338W04
(AVERAGE, Channel 78, 8-DPSK)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 101 of 111

REPORT No.SZ23050338W04
A.12. Radiated Emission
According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform an quasi-peak measurement (or average).
The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 10th harmonic of the highest frequency, was pre-scanned and the result which was 20dB lower than the limit was not recorded.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 102 of 111

GFSK Mode Plots for Channel 0

REPORT No.SZ23050338W04

Fre. (MHz)
110.510 1971.200 4109.200 5556.800 8461.240 12209.600

PK (dBV/m)
32.56 46.95
45.54
47.48 47.17
47.83

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
99.840 1884.267 3939.800 5643.040 9003.320 12881.040

PK (dBV/m)
32.65 47.41
45.34
47.95 47.18
48.28

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 103 of 111

Plot for Channel 39

REPORT No.SZ23050338W04

Fre. (MHz)
102.750 1922.133 3844.320 5356.600 9206.600 12896.440

PK (dBV/m)
32.03
47.27 45.22
47.03
46.94 47.56

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
104.690 2453.333 3835.080 4996.240 8433.520 11002.240

PK (dBV/m)
31.99 47.08
44.73
46.37 47.58
48.04

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 104 of 111

Plot for Channel 78

REPORT No.SZ23050338W04

Fre. (MHz)
111.480 1907.733 3714.960 5643.040 8384.240 12212.680

PK (dBV/m)
31.89
47.11 44.21
47.14
47.53 49.06

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
113.420 2086.933 3678.000 5704.640 9031.040 12680.840

PK (dBV/m)
32.08
47.66 44.63
46.51
47.30 47.40

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 105 of 111

/4-DQPSK Mode Plots for Channel 0

REPORT No.SZ23050338W04

Fre. (MHz)
105.660 1577.067 3890.520 5667.680 8501.280 12610.000

PK (dBV/m)
31.55 47.12
44.61
46.75 46.65
48.17

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna Verdict

Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

PASS PASS PASS PASS PASS PASS

Fre. (MHz)
98.870 1988.267 4414.120 5673.840 8458.160 12576.120

PK (dBV/m)
31.20 47.70
45.85
48.63 47.75
47.53

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 106 of 111

Plot for Channel 39

REPORT No.SZ23050338W04

Fre. (MHz)
100.810 2023.467 3850.480 5067.080 10284.600 12887.200

PK (dBV/m)
31.50
47.51 45.17
46.19
48.24 47.68

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
102.750 1457.600 3684.160 5393.560 8470.480 12893.360

Pk (dBV/m)
32.54 47.46
44.58
46.84 47.70
48.02

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 107 of 111

Plot for Channel 78

REPORT No.SZ23050338W04

Fre. (MHz)
109.540 1866.667 3872.040 5667.680 7986.920 12132.600

Pk (dBV/m)
31.30
47.19 45.10
47.88
46.76 47.23

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
112.450 1544.000 3770.400 5193.360 8960.200 10355.440

Pk (dBV/m)
32.55 47.38
45.00
46.26 47.24
47.87

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 108 of 111

8-DPSK Mode Plots for Channel 0

REPORT No.SZ23050338W04

Fre. (MHz)
106.630 1684.267 4189.280 5787.800 8390.400 12902.600

Pk (dBV/m)
31.28 47.03
44.88
47.14 47.95
48.24

QP (dBV/m)
N/A

AV (dBV/m)
N/A

Limit-PK (dBV/m)
N/A

Limit-QP (dBV/m)
43.50

Limit-AV (dBV/m)
N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
106.630 2490.133 3893.600 5174.880 8408.880 12188.040

Pk (dBV/m)
31.31 48.08
45.47
46.81 47.74
48.22

QP (dBV/m)
N/A

AV (dBV/m)
N/A

Limit-PK (dBV/m)
N/A

Limit-QP (dBV/m)
43.50

Limit-AV (dBV/m)
N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 109 of 111

Plot for Channel 39

REPORT No.SZ23050338W04

Fre. (MHz)
100.810 1925.333 3890.520 5716.960 9058.760 12591.520

Pk (dBV/m)
31.74
47.07 44.91
47.64
47.31 47.37

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
110.510 1880.533 3887.440 5670.760 8455.080 12511.440

Pk (dBV/m)
31.69 46.87
45.11
47.04 47.72
47.90

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 110 of 111

Plot for Channel 78

REPORT No.SZ23050338W04

Fre. (MHz)
110.510 1678.400 3745.760 4959.280 8365.760 12194.200

Pk (dBV/m)
31.47
46.79
44.36 45.80
47.02
47.90

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Horizontal, 30MHz to 18GHz)

Antenna
Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Verdict
PASS PASS PASS PASS PASS PASS

Fre. (MHz)
103.720 2029.333 3791.960 5867.880 8448.920 12151.080

Pk (dBV/m)
32.28 46.56
44.43
48.32 47.20
47.62

QP

AV

Limit-PK Limit-QP Limit-AV

(dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m)

N/A

N/A

N/A

43.50

N/A

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

N/A

N/A

74.00

N/A

54.00

(Antenna Vertical, 30MHz to 18GHz)

Antenna
Vertical Vertical Vertical Vertical Vertical Vertical

Verdict
PASS PASS PASS PASS PASS PASS

END OF REPORT

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 111 of 111


Acrobat Distiller 11.0 (Windows)