14-1011-27 1Q SH 01/01/2012 American Standard 2012 Quick Reference Guide Split System Heat Pumps Section

mroche

PDF preview unavailable. Download the PDF instead.

American Standard 4A6H3042B1000A Catalog
Split System Heat Pumps Single Phase ­ 1½-5 Tons

Gold SI (4A6H3-B)

Table SH-3-A-- Gold SI Heat Pump (Previously Heritage 13)

Model Number

Power Suppy

Nom. Cap. Cooling (BTUH)

Uncrated Dimensions(in.) HW D

Shipping Weight (lbs.)

4A6H3018C1000A 208/230/1/60 19,000 29 33 30 189

4A6H3024C1000A 208/230/1/60 24,000 29 33 30 191

4A6H3030B1000A 200/230/1/60 29,400 33 33 30 221

4A6H3036B1000A 208/230/1/60 34,800 33 37 34 261

4A6H3042B1000A 208/230/1/60 41,500 33 37 34 253

4A6H3048B1000A 208/230/1/60 47,000 37 37 34 269

4A6H3060B1000A 208/230/1/60 57,500 41 37 34 284

Sound** Rating
76 75 76 75 75 75 75

MCA* 9 12 15 18 26 28 34

Max.
Fuse* 15 20 25 30 45 50 60

Line Size OD OD Gas Liq.
5/8 3/8 5/8 3/8 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/8 7/8 3/8

Silver XI (4A6B4)

Table SH-3-B-- Silver XI Heat Pump (Previously American Standard 14)

Model Number

Power Suppy

Nom. Cap. Cooling (BTUH)

Uncrated Dimensions(in.) HW D

Shipping Weight (lbs.)

Sound**
Rating MCA*

4A6B4018G1000A 208/230/1/60 18,000 29 33 30 204

76 9

4A6B4024G1000A 208/230/1/60 24,000 33 33 30 236

76 11

4A6B4030G1000A 208/230/1/60 30,000 33 37 34 273

78 15

4A6B4036G1000A 208/230/1/60 36,000 33 37 34 261

76 18

4A6B4042E1000A 208/230/1/60 42,000 41 37 34 313

78 27

4A6B4048E1000A 208/230/1/60 48,000 45 37 34 331

78 29

4A6B4049E1000B 208/230/1/60 48,000 45 37 34 331

76 28

4A6B4060E1000A 208/230/1/60 60,000 45 37 34 332

78 35

4A6B4061E1000A 208/230/1/60 60,000 45 37 34 332

76 36

Max.
Fuse* 15 15 25 30 45 50 50 60 60

Line Size OD OD Gas Liq.
5/8 3/8 5/8 3/8 3/4 3/8 3/4 3/8 3/4 3/8 7/8 3/8 7/8 3/8 7/8 3/8 11/8 3/8

Silver SI (4A6B3)

Table SH-3-C-- Silver SI Heat Pump (Previously American Standard 13)

Model Number

Power Suppy

Nom. Cap. Cooling (BTUH)

Uncrated Dimensions(in.) HW D

Shipping Weight (lbs.)

Sound**
Rating MCA*

Max.
Fuse*

Line Size OD OD Gas Liq.

4A6B3018B1000A 208/230/1/60 17,000 29 33 30 201

79 9

15

5/8 3/8

PHASING 4A6B3024B1000A 208/230/1/60 23,000 29 33 30 204

81

4A6B3030B1000A 208/230/1/60 28,500 33 33 30 221

80

4A6B3036B1000A 208/230/1/60 34,500 33 37 34 261

79

4A6B3042B1000A 208/230/1/60 40,500 33 37 34 253

80

OUT 12

20

5/8 3/8

15

25

3/4 3/8

18

30

3/4 3/8

26

45

3/4 3/8

4A6B3048B1000A 208/230/1/60 46,500 37 37 34 269

78 28

50

7/8 3/8

4A6B3060B1000A 208/230/1/60 58,500 41 37 34 284

78 34

60

7/8 3/8

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

** Rated in accordance with AHRI Standard 270-2008.

Silver SI (4TWB3)

Table SH-3-D -- Silver SI Heat Pump (Previously American Standard 13)

Model Number

Power Supply

Nom. Cap. Cooling (BTUH)

Uncrated Dimensions(in.) HW D

Shipping Weight Sound** (lbs.) Rating

Line Size (in) Max. OD OD MCA* Fuse* Gas Liq.

4TWB3018C1000A 208/230/1/60 17,000 29 33 30 189 79

9 15 5/8 3/8

4TWB3024C1000A 208/230/1/60 23,000 29 33 30 191 81

12 20 5/8 3/8

4TWB3030B1000B 208/230/1/60 28,500 33 33 30 221 80

15 25 3/4 3/8

4TWB3036B1000B 208/230/1/60 34,500 33 37 34 261 79

18 30 3/4 3/8

4TWB3042B1000B 208/230/1/60 40,500 33 37 34 253 80

26 45 3/4 3/8

4TWB3048B1000B 208/230/1/60 46,500 37 37 34 269 78

28 50 7/8 3/8

4TWB3060B1000B 208/230/1/60 58,500 41 37 34 284 78

34 60 7/8 3/8

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

** Rated in accordance with AHRI Standard 270-2008.

For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.

SH-3

Effective 1/1/12 14-1011-27

Split System Heat Pumps Single Phase ­ 1½-5 Tons

PHASING OUT

Table SH-4-A -- Features

(4A6H3-B) (4A6B4)

s 3%%2UPTO ......................................................................................................................................... s (30&UPTO.......................................................................................................................................... s DurationTM compressor...................................................................................................................... s Comfort-RTM mode approved............................................................................................................. s DuraBaseTM base, fast complete drain, weatherproof ....................................................................... s Easy-SessTM cabinet, service access & refrigerant connections with full coil protection .................. s Spine FinTM coil .................................................................................................................................. s #OMPRESSORSUMPHEAT
FACTORYINSTALLED .......................................................................................... s $EMAND$EFROST#ONTROLW/Lite PortTM/Stored Diagnostics ............................................................... s 1UICKSTARTKIT
FACTORYINSTALLED ........................................................................................................... s ,OW0RESSURE3WITCH........................................................................................................................... s &ACTORYSUPPLIEDCHARGE..................................................................................................................... s 'LOSSYCORROSIONRESISTANTlNISH ......................................................................................................... s (IGHPRESSURESWITCH........................................................................................................................... s )NTERNALHIGHLOWPRESSURETEMPERATUREPROTECTION ........................................................................ s ,IQUIDLINElLTERDRIER
FACTORYINSTALLED................................................................................................ s 0OLYSLATEGRAYCABINET ......................................................................................................................... s 3PINNAKERGRAYCABINET........................................................................................................................ s 10-year registered limited warranty on compressor,
outdoor coil & all other functional parts (Residential Use)3 .....................................................
s Extended warranties available ........................................................................................................

14.50 9.00
     --  1½-3,5 3.5-5 R-410A     -- 
 

16.00 9.00
       1½-3,5 3.5-5 R-410A      --
 

(4A6B3)
14.00 8.50
     --  1½-3 3.5-5 R-410A      --
 

(4TWB3)
14.00 8.50
     --  1½-3 3.5-5 R-410A      --
 

Table SH-4-B -- Optional Accessories

Model Number

Description

Shipping Weight

AY28X084....................Evaporator Defrost Control .................................. 1 ........................................... BAYCCHT300 .............#RANKCASE(EATER+IT2ECIPROCATING ................. 1 ........................................... BAYCCHT301 .............#RANKCASE(EATER+IT3CROLL .............................. 1 ........................................... BAYECMT023 .............%XTREME#ONDITIONS-OUNTING+IT"ASE ....... 2 ........................................... BAYECMT004 .............%XTREME#ONDITIONS-OUNTING+IT"ASE .......... 2 ........................................... BAYINS001..................Insulation Kit....................................................................................................... BAYISLT101 ................Rubber Isolators................................................... 1 ........................................... BAYKSKT260 .............3TARTKIT3CROLL ..................................................... 1 ........................................... BAYLEGS002A ...........3NOW,EGS"ASEAND#AP(IGH"LACK  ......... 1 ........................................... BAYLEGS003A ...........%XTENSION"LACK ............................................. 1 ........................................... BAYLOAM103 .............Low Ambient Kit ................................................... 1 ........................................... BAYSEAC001..............Seacoast Kit ......................................................... 1 ........................................... TAYASCT501A12 .....Anti-Short Cycle Timer ......................................... 2 ........................................... TAYPLUS103A ............Heat Pump Control Kit ......................................... 3 ........................................... PAI003095..................Heresite Spraypaint.............................................. 1 ...........................................

 1½-3 3½-5 1½-2½ 3-5
  3½-4       

 1½-3 3½-5 1½-2½ 3-5
  3½-5   4    

PHASING OUT

 1½-3 3½-5 1½-2½ 3-5
  3½-5       

 1½-3 3½-5 1½-2½ 3-5
  3½-5       

Comfort Controls -- See Comfort Controls/Zone Sensors Section
1 Not for use with programmable thermostats. 2 Activated on Power Off. 3 Registered Limited Warranty terms are available when you register within 60 days of installation. You can register online at americanstandardair.com or by phone
at 800-554-8005; otherwise American Standard Heating & Air Conditioning's Base Limited Warranty terms will apply. Base Limited Warranty information on specific products can be found on ASDealerNet.com. 4 For operation to 20°F outdoor ambient. 55SEDFORADDITIONALSEACOASTCORROSIONPROTECTION2EFERTOBULLETINNUMBER5.
36"!
%.FORAPPLICATIONINFORMATION

For complete equipment / combination selections, installation instructions and warranty information, please refer to Product Data/Ratings and/or Installers Guides and Limited Warranty Handbooks.

SH-4

Effective 1/1/12 14-1011-27


Acrobat Distiller 8.1.0 (Windows)