SINUMERIK 840D sl Upgrade Instructions SINUMERIK Operate 4.5 SP4 for PCU 50.5

PDF preview unavailable. Download the PDF instead.

siemense Operate 45 SP4 PCU50
SINUMERIK 840D sl

2014-10-28

Upgrade Instructions

SINUMERIK Operate 4.5 SP4 for PCU 50.5
freely Available
_________________________________________________________________________________________

SINUMERIK Operate 04.05.04.00 (internal Version 04.05.04.00.010) for PCU 50.5 _________________________________________________________________________________________

A PCU 50.5 with pre-installed PCU base software WinXP from V1.3 or a PCU 50.5 with pre-installed PCU base software Win7 V1.0 is required in order to install this software:: - PCU 50.5-C/XP 6FC5210-0DF52-2AA0 with PCU base software from V1.3 - PCU 50.5-P/XP 6FC5210-0DF53-2AA0 with PCU base software from V1.3 - PCU 50.5-C/W7 6FC5210-0DF52-3AA0 with PCU base software from V1.0 - PCU 50.5-P/W7 6FC5210-0DF53-3AA0 with PCU base software from V1.0

The Commissioning Guide for SINUMERIK Operate Operate 4.5 SP2, PCU base software V1.3 or Win7 V1.0, the Operator Components Manual and the Operating Manual SINUMERIK Operate 4.5 SP2 apply. Furthermore, the supplementary conditions published for CNC Software 4.5 SP4 must be taken into account.

Before using SINUMERIK Integrate for Production (SIP), please read the notes provided in the Annex "SINUMERIK_Integrate_liesmich_Operate_45SP4.pdf".

SINUMERIK Operate comprises all texts in German, English, French, Italian, Spanish and "Chinese simplified". In general, the help for setting and machine data is only provided in German and English. The V2.7.1 additional languages for SINUMERIK Operate can be used.

SINUMERIK Operate 4.5 SP4 has only been released for operating x an 840D sl NCU7x0 with CNC Software 4.5 SP4 or for a
x SIMATIC-CPU 317 / 319 in combination with HMI Pro sl. To do this, the PCU 50 must be integrated in the plant / system network. By default, the SINUMERIK Operate is connected to the NCU address 192.168.214.1. The NCU address can be set in the "NCU connection" screen under Commissioning / HMI. Note for laboratory operation: When connecting the PCU 50 to the X130 of the NCU, the simulation cannot be executed.

The SINUMERIK Operate for PCU 50 does not include any technological cycles or measuring and ISO cycles. These are available on the CF card of the NCU and are automatically installed during the NCU startup ­ see also the relevant information provided in the Upgrade Instructions for the CNC Software 4.5 SP4.

User texts must always be downloaded into the system in the UTF-8 format.

SINUMERIK Operate for PCU 50 does not have general access to the CF card of the NCU. This means that option "user memory on CF card of the NCU" cannot be used. The "Local drive" in SINUMERIK Operate for PCU 50 is located on the hard disk under F:\hmisl\user\sinumerik\data and is always available without option.

STEP7 5.5 for SINUMERIK PCU 50 can also be integrated for SINUMERIK Operate. The desktop function "Step7 authorization" is used for this purpose.

Important note for operation on PCU 50.5 Windows 7: Before deactivating the power supply of the PCU 50.5, shut down the system via the Operate softkey EXIT resp. Windows shutdown, analogously to a PC with Windows 7. You can use a UPS to protect the system against unexpected power cuts. The EXIT softkey can be made accessible to all operators by setting the display MD 9110 = 7.

Installation Important: If a version <= 4.5 SP2 of SINUMERIK Operate for PCU 50 has already been installed, it must first be

© Siemens AG 2014 All rights reserved

I DT MC R&D 5

Page 1 of 4

SINUMERIK 840D sl

2014-10-28

Upgrade Instructions SINUMERIK Operate 4.5 SP3 HF2 for PCU 50.5

uninstalled under Control Panel / Add or Remove Programs or Programs and Features. SINUMERIK Operate for PCU 50 is installed by calling the file Setup_HMIsl_......exe from the Windows desktop of the PCU 50. To do this, establish either a network connection to a PC using the DVD supplied or copy the software from the DVD supplied to a USB data medium that can then be directly connected to the PCU 50.3. The installation directory is permanently specified as f:\hmisl or c:\Program Files. The installation version is requested during the installation:
x Operation on a SINUMERIK NCU (default) x Operation on a SIMATIC-CPU 317 / 319 x Integration of .NET-Framework for OEM applications

Function improvements in Operate SW 4.5 SP4 compared to SW 4.5 SP3 HF2:

PR number

225037

225435

226003

226012

226161

226185

226266

226269

226302

226360

226373

226375

226396

298159

305097

306625

308384

308405

308568

308950

309189

309309

310320

310366

310433

310753

310992

310996

311533

311806

312013

312119

312128

312281

312731

312866

313240

314713

314895

315977

315983

316835

316841

317161

317511

318224

318227

318269

321235

321817

322470

322622

322728

322894

323045

323051

323629

323734

323755

325048

325106

325267

325521

325726

325837

325844

326040

326471

326549

327032

327676

327927

328179

328587

329486

329793

329810

330322

330334

331375

331613

331990

332018

332331

333785

333828

334403

334613

334816

334970

334983

336582

300998

328717

226103 226332 298576 308617 310428 311772 312383 315964 317351 321320 322966 324073 325768 326956 328688 331116 332598 334930

Function improvements in Operate SW 4.5 SP3 HF2 compared to SW 4.5 SP3 HF1:

PR number

298305

298309

298791

309190

306250

Function improvements in Operate SW 4.5 SP3 HF1 compared to SW 4.5 SP3:

PR number:

AP01600629

AP01600418

298306

298304

298173

Function improvements in Operate SW 4.5 SP3 compared to SW 4.5 SP2 HF4:

PR number:

AP01346367

AP01391082

AP01420102

AP01480648

AP01490353

AP01497696

AP01499269

AP01504646

AP01505147

AP01514499

AP01515592

AP01522116

AP01522651

AP01522858

AP01524335

AP01526932

AP01527942

AP01530542

AP01531894

AP01537486

AP01540703

AP01541443

AP01541724

AP01542532

AP01545746

AP01545955

AP01546093

AP01548921

AP01549206

AP01554790

AP01555581

AP01556010

AP01556150

AP01556379

AP01557835

AP01558129

AP01560162

AP01561224

AP01563018

AP01564804

AP01568067

AP01569241

AP01570136

AP01570396

AP01573010

AP01573603

AP01573677

AP01574302

AP01574754

AP01575754

AP01575855

AP01576692

AP01577258

AP01577739

AP01579353

AP01579878

AP01580389

AP01580604

AP01580796

298290
AP01481109 AP01508971 AP01523166 AP01532925 AP01545702 AP01550296 AP01556747 AP01563236 AP01571221 AP01574882 AP01577880 AP01580879

© Siemens AG 2014

Page 2 of 4

SINUMERIK 840D sl

Upgrade Instructions SINUMERIK Operate 4.5 SP3 HF2 for PCU 50.5

AP01581342 AP01583052 AP01589476 AP01592058 AP01597712

AP01581929 AP01584985 AP01589524 AP01594397 AP01598853

AP01582228 AP01585041 AP01589615 AP01594591

AP01582393 AP01585860 AP01589966 AP01595100

AP01582526 AP01587126 AP01590460 AP01595394

2014-10-28
AP01582751 AP01588294 AP01590715 AP01596303

==================================================================== Compatibility ==================================================================== x SINUMERIK Operate 4.5 SP4 can be combined with 840D sl NCU 7x0.3 with CNC SW 4.5 SP4. x The help system is based on the documentation for the CNC SW 4.5 SP2. x The NC alarm texts are based on the CNC SW 4.5 SP2. x STEP7 for SINUMERIK PCU 50 from V5.5 can be integrated in SINUMERIK Operate 4.5 SPx where it can
run. x OEM applications which are based on the SINUMERIK Operate Programming Package 4.5 can run when
using generally released interfaces. x The available additional languages V4.5.2 for SINUMERIK Operate can be used.

====================================================================

Notes

====================================================================

System:

x If, in conjunction with STEP7 on PCU 50 WinXP, no communication is established between the HMI and the

NCU, please check the settings made under Control Panel / Set PG/PC Interface. In addition to S7ONLINE,

an Access Point

SINUMERIK_CP (SINUMERIK 7xx) -> TCP/IP -> VIA Rhine III Fast Eth. ..<Board 2>

must be included. If necessary, configure this Access Point as indicated.

x Editor: The key combination Shift+Insert must be used to edit cycle calls directly in the DIN code. At present,

this is not provided on all SINUMERIK OPs. Remedy: Use an external PC keyboard.

x To operate the simulation, the NC-MD $MC_FRAME_ACS_SET must be set to 1.

x To operate a PCU50 with an external monitor, you can set the screen size of the Operate in the file

F:\hmisl\user\sinumerik\hmi\cfg\run_hmi.ini with the entry

[Global]

Resolution =

; permissible values: 640x480, 800x600, 1024x768, 1280x1024

x As standard, in the Machine area, the "Retract" softkey is no longer available. It can be reactivated by

creating the slmaconfig.xml in /oem/sinumerik/hmi/cfg file with the following content:

<?xml version="1.0" encoding="UTF-8" standalone="yes" ?>

<CONFIGURATION>

<Settings>

<ShowRetractSoftkey type="bool" value="true" />

</Settings></CONFIGURATION>

x Subsequently enter Autostart of Operate for a (another) user on PCU 50.5-Win7:

On the desktop, start menu "All Programs", select Startup. Right-click on "Open". An Explorer is then

opened. In the right-hand window of Explorer, right click on "New" create " Shortcut".

Then using "Browse ...", enter the "C:\Program Files(x86)\Siemens\MotionControl \siemens\sinumerik\hmi\

autostart\slstartup.exe" file.

x The "AppSight-Blackbox" is available in Operate (resource to analyze the causes of application crashes) and

is active as standard. It can be deactivated using an entry in the run_hmi.ini file:

[AppSight]

; enabled could be set to true or false. Default: true

enabled=true

The log file generated by AppSight-Blackbox in the case of a fault is called:

© Siemens AG 2014

Page 3 of 4

SINUMERIK 840D sl

2014-10-28

Upgrade Instructions SINUMERIK Operate 4.5 SP3 HF2 for PCU 50.5

.../user/sinumerik/hmi/log/hmi/blackbox_run_hmi.asl It is written to when exiting Operate. It may be necessary to explicitly exit processes that are running. Together with the HMI crash or, this log file must be sent to the SINUMERIK hotline.

© Siemens AG 2014

Page 4 of 4


PDF-XChange 4.0.194.0 (Windows Seven Ultimate x64 Service Pack 1 (Build 7601))