SINUMERIK 840D sl Upgrade Instructions SINUMERIK Operate 4.5 SP4 for PCU 50.5
siemense Operate 45 SP4 PCU50 SINUMERIK 840D sl
2014-10-28
Upgrade Instructions
SINUMERIK Operate 4.5 SP4 for PCU 50.5
freely Available
_________________________________________________________________________________________
SINUMERIK Operate 04.05.04.00 (internal Version 04.05.04.00.010) for PCU 50.5 _________________________________________________________________________________________
A PCU 50.5 with pre-installed PCU base software WinXP from V1.3 or a PCU 50.5 with pre-installed PCU base software Win7 V1.0 is required in order to install this software:: - PCU 50.5-C/XP 6FC5210-0DF52-2AA0 with PCU base software from V1.3 - PCU 50.5-P/XP 6FC5210-0DF53-2AA0 with PCU base software from V1.3 - PCU 50.5-C/W7 6FC5210-0DF52-3AA0 with PCU base software from V1.0 - PCU 50.5-P/W7 6FC5210-0DF53-3AA0 with PCU base software from V1.0
The Commissioning Guide for SINUMERIK Operate Operate 4.5 SP2, PCU base software V1.3 or Win7 V1.0, the Operator Components Manual and the Operating Manual SINUMERIK Operate 4.5 SP2 apply. Furthermore, the supplementary conditions published for CNC Software 4.5 SP4 must be taken into account.
Before using SINUMERIK Integrate for Production (SIP), please read the notes provided in the Annex "SINUMERIK_Integrate_liesmich_Operate_45SP4.pdf".
SINUMERIK Operate comprises all texts in German, English, French, Italian, Spanish and "Chinese simplified". In general, the help for setting and machine data is only provided in German and English. The V2.7.1 additional languages for SINUMERIK Operate can be used.
SINUMERIK Operate 4.5 SP4 has only been released for operating x an 840D sl NCU7x0 with CNC Software 4.5 SP4 or for a
x SIMATIC-CPU 317 / 319 in combination with HMI Pro sl. To do this, the PCU 50 must be integrated in the plant / system network. By default, the SINUMERIK Operate is connected to the NCU address 192.168.214.1. The NCU address can be set in the "NCU connection" screen under Commissioning / HMI. Note for laboratory operation: When connecting the PCU 50 to the X130 of the NCU, the simulation cannot be executed.
The SINUMERIK Operate for PCU 50 does not include any technological cycles or measuring and ISO cycles. These are available on the CF card of the NCU and are automatically installed during the NCU startup see also the relevant information provided in the Upgrade Instructions for the CNC Software 4.5 SP4.
User texts must always be downloaded into the system in the UTF-8 format.
SINUMERIK Operate for PCU 50 does not have general access to the CF card of the NCU. This means that option "user memory on CF card of the NCU" cannot be used. The "Local drive" in SINUMERIK Operate for PCU 50 is located on the hard disk under F:\hmisl\user\sinumerik\data and is always available without option.
STEP7 5.5 for SINUMERIK PCU 50 can also be integrated for SINUMERIK Operate. The desktop function "Step7 authorization" is used for this purpose.
Important note for operation on PCU 50.5 Windows 7: Before deactivating the power supply of the PCU 50.5, shut down the system via the Operate softkey EXIT resp. Windows shutdown, analogously to a PC with Windows 7. You can use a UPS to protect the system against unexpected power cuts. The EXIT softkey can be made accessible to all operators by setting the display MD 9110 = 7.
Installation Important: If a version <= 4.5 SP2 of SINUMERIK Operate for PCU 50 has already been installed, it must first be
© Siemens AG 2014 All rights reserved
I DT MC R&D 5
Page 1 of 4
SINUMERIK 840D sl
2014-10-28
Upgrade Instructions SINUMERIK Operate 4.5 SP3 HF2 for PCU 50.5
uninstalled under Control Panel / Add or Remove Programs or Programs and Features. SINUMERIK Operate for PCU 50 is installed by calling the file Setup_HMIsl_......exe from the Windows desktop of the PCU 50. To do this, establish either a network connection to a PC using the DVD supplied or copy the software from the DVD supplied to a USB data medium that can then be directly connected to the PCU 50.3. The installation directory is permanently specified as f:\hmisl or c:\Program Files. The installation version is requested during the installation:
x Operation on a SINUMERIK NCU (default) x Operation on a SIMATIC-CPU 317 / 319 x Integration of .NET-Framework for OEM applications
Function improvements in Operate SW 4.5 SP4 compared to SW 4.5 SP3 HF2:
PR number
225037
225435
226003
226012
226161
226185
226266
226269
226302
226360
226373
226375
226396
298159
305097
306625
308384
308405
308568
308950
309189
309309
310320
310366
310433
310753
310992
310996
311533
311806
312013
312119
312128
312281
312731
312866
313240
314713
314895
315977
315983
316835
316841
317161
317511
318224
318227
318269
321235
321817
322470
322622
322728
322894
323045
323051
323629
323734
323755
325048
325106
325267
325521
325726
325837
325844
326040
326471
326549
327032
327676
327927
328179
328587
329486
329793
329810
330322
330334
331375
331613
331990
332018
332331
333785
333828
334403
334613
334816
334970
334983
336582
300998
328717
226103 226332 298576 308617 310428 311772 312383 315964 317351 321320 322966 324073 325768 326956 328688 331116 332598 334930
Function improvements in Operate SW 4.5 SP3 HF2 compared to SW 4.5 SP3 HF1:
PR number
298305
298309
298791
309190
306250
Function improvements in Operate SW 4.5 SP3 HF1 compared to SW 4.5 SP3:
PR number:
AP01600629
AP01600418
298306
298304
298173
Function improvements in Operate SW 4.5 SP3 compared to SW 4.5 SP2 HF4:
PR number:
AP01346367
AP01391082
AP01420102
AP01480648
AP01490353
AP01497696
AP01499269
AP01504646
AP01505147
AP01514499
AP01515592
AP01522116
AP01522651
AP01522858
AP01524335
AP01526932
AP01527942
AP01530542
AP01531894
AP01537486
AP01540703
AP01541443
AP01541724
AP01542532
AP01545746
AP01545955
AP01546093
AP01548921
AP01549206
AP01554790
AP01555581
AP01556010
AP01556150
AP01556379
AP01557835
AP01558129
AP01560162
AP01561224
AP01563018
AP01564804
AP01568067
AP01569241
AP01570136
AP01570396
AP01573010
AP01573603
AP01573677
AP01574302
AP01574754
AP01575754
AP01575855
AP01576692
AP01577258
AP01577739
AP01579353
AP01579878
AP01580389
AP01580604
AP01580796
298290
AP01481109 AP01508971 AP01523166 AP01532925 AP01545702 AP01550296 AP01556747 AP01563236 AP01571221 AP01574882 AP01577880 AP01580879
© Siemens AG 2014
Page 2 of 4
SINUMERIK 840D sl
Upgrade Instructions SINUMERIK Operate 4.5 SP3 HF2 for PCU 50.5
AP01581342 AP01583052 AP01589476 AP01592058 AP01597712
AP01581929 AP01584985 AP01589524 AP01594397 AP01598853
AP01582228 AP01585041 AP01589615 AP01594591
AP01582393 AP01585860 AP01589966 AP01595100
AP01582526 AP01587126 AP01590460 AP01595394
2014-10-28
AP01582751 AP01588294 AP01590715 AP01596303
==================================================================== Compatibility ==================================================================== x SINUMERIK Operate 4.5 SP4 can be combined with 840D sl NCU 7x0.3 with CNC SW 4.5 SP4. x The help system is based on the documentation for the CNC SW 4.5 SP2. x The NC alarm texts are based on the CNC SW 4.5 SP2. x STEP7 for SINUMERIK PCU 50 from V5.5 can be integrated in SINUMERIK Operate 4.5 SPx where it can
run. x OEM applications which are based on the SINUMERIK Operate Programming Package 4.5 can run when
using generally released interfaces. x The available additional languages V4.5.2 for SINUMERIK Operate can be used.
====================================================================
Notes
====================================================================
System:
x If, in conjunction with STEP7 on PCU 50 WinXP, no communication is established between the HMI and the
NCU, please check the settings made under Control Panel / Set PG/PC Interface. In addition to S7ONLINE,
an Access Point
SINUMERIK_CP (SINUMERIK 7xx) -> TCP/IP -> VIA Rhine III Fast Eth. ..<Board 2>
must be included. If necessary, configure this Access Point as indicated.
x Editor: The key combination Shift+Insert must be used to edit cycle calls directly in the DIN code. At present,
this is not provided on all SINUMERIK OPs. Remedy: Use an external PC keyboard.
x To operate the simulation, the NC-MD $MC_FRAME_ACS_SET must be set to 1.
x To operate a PCU50 with an external monitor, you can set the screen size of the Operate in the file
F:\hmisl\user\sinumerik\hmi\cfg\run_hmi.ini with the entry
[Global]
Resolution =
; permissible values: 640x480, 800x600, 1024x768, 1280x1024
x As standard, in the Machine area, the "Retract" softkey is no longer available. It can be reactivated by
creating the slmaconfig.xml in /oem/sinumerik/hmi/cfg file with the following content:
<?xml version="1.0" encoding="UTF-8" standalone="yes" ?>
<CONFIGURATION>
<Settings>
<ShowRetractSoftkey type="bool" value="true" />
</Settings></CONFIGURATION>
x Subsequently enter Autostart of Operate for a (another) user on PCU 50.5-Win7:
On the desktop, start menu "All Programs", select Startup. Right-click on "Open". An Explorer is then
opened. In the right-hand window of Explorer, right click on "New" create " Shortcut".
Then using "Browse ...", enter the "C:\Program Files(x86)\Siemens\MotionControl \siemens\sinumerik\hmi\
autostart\slstartup.exe" file.
x The "AppSight-Blackbox" is available in Operate (resource to analyze the causes of application crashes) and
is active as standard. It can be deactivated using an entry in the run_hmi.ini file:
[AppSight]
; enabled could be set to true or false. Default: true
enabled=true
The log file generated by AppSight-Blackbox in the case of a fault is called:
© Siemens AG 2014
Page 3 of 4
SINUMERIK 840D sl
2014-10-28
Upgrade Instructions SINUMERIK Operate 4.5 SP3 HF2 for PCU 50.5
.../user/sinumerik/hmi/log/hmi/blackbox_run_hmi.asl It is written to when exiting Operate. It may be necessary to explicitly exit processes that are running. Together with the HMI crash or, this log file must be sent to the SINUMERIK hotline.
© Siemens AG 2014
Page 4 of 4
PDF-XChange 4.0.194.0 (Windows Seven Ultimate x64 Service Pack 1 (Build 7601))