~{EN}Liebert PDX, brochure, english, direct expansion, DX, Thermal Management, Liebert, PDX, identification, evaluation, selection, data center, perimeter cooling, efficiency, EC fans, MKA4L0UKPDX..

Dalma Ricci

PDX from 15 to 165 kW - Vertiv

2 LIEBERT PDX from 15 to 165 kW It comes complete with R410A refrigerant which allows the unit to reach significant levels of efficiency. The Liebert PDX

PDF preview unavailable. Download the PDF instead.

liebert-pdx-15-120-kw-brochure-english
Liebert®
PDX from 15 to 165 kW
Direct Expansion Solution for Small and Medium Data Centers

LIEBERT® PDX from 15 to 165 kW
VertivTM
Vertiv designs, builds and services mission critical technologies that enable the vital applications for data centers, communication networks, and commercial and industrial environments. We support today's growing mobile and cloud computing markets with our portfolio of power, thermal, infrastructure management products, software and solutions, all complemented by our global service network. Bringing together global reach and local knowledge, and our decades-long heritage including brands like Chloride®, Liebert® and NetSureTM our team of experts is ready to take on your most complex challenges, creating solutions that keep your systems running--and your business moving. Together, we're building the future of a world where critical technologies always work. YOUR VISION, OUR PASSION. VertivCo.eu
The Liebert® PDX direct expansion cooling unit is equipped with the most advanced industry technology, guaranteeing precise cooling of data centers and server rooms.
It comes complete with R410A refrigerant which allows the unit to reach significant levels of efficiency. The Liebert PDX range also includes new generation Liebert EC Fans 2.0, thus ensuring top energy efficiency. The complete unit design has furthermore been optimized with enhanced heat exchangers, delivering high levels of overall efficiency and cooling capacity. In addition, Liebert PDX also includes unique Digital Scroll technology, making it the ideal, scalable cooling system able to expand with evolving business needs. The Digital Scroll modulating capability greatly contributes to the efficiency levels reached by Liebert PDX with a 50 kW unit (inclusive of Digital Scroll) consuming as little as a 10 kW unit, thus delivering advantageous energy savings.
2

Liebert PDX designed for ultimate energy efficiency
3

LIEBERT® PDX from 15 to 165 kW

Liebert® PDX Key Features

R410A Refrigerant Designed for R410A Refrigerant.
Copeland Digital Scroll Technology The best solution in terms of variable cooling capacity.

European ErP 2015 Directive
Precision cooling floor mount products comply with the European ErP 2015 Directive requirements, respecting environmental commitments while reducing operating costs.

Eurovent Certified Eurovent certification guarantees that Liebert PDX undergoes independent testing, thus delivering rating accuracy and enhancing the unit's reliability. Check ongoing validity of certificate: www.eurovent-certification.com

23° 22° 21° 20° 19° 18° 17°
Precise Temperature Control
Digital Scroll based technology allows
for close monitoring and control of room
temperature.

Energy Efficiency
First-class energy efficiency achieved through the combination of market leading technologies.

Heat Load Monitoring
Continuous monitoring of heat load ensures that only necessary kilowatts are invested in targeted cooling, thus conserving energy.

Liebert® EC Fan 2.0
The new generation of Liebert EC Fan 2.0 is the core of the Liebert PDX, significantly minimizing noise levels and increasing the efficiency of the unit.

Ultrasonic Humidifier - The Efficient Humidification Technology
Liebert PDX's cutting-edge technology allows each of its components to save energy while delivering the required data center cooling performance. The infrared and electrode boiler humidifier are two efficient options made available.

24x7 Service Offering
Vertiv supports customers with an extensive service offering, guaranteeing availability and total peace of mind 24/7.

Electronic Expansion Valve This valve is designed to constantly optimize the refrigeration circuit's performance in order to achieve the highest efficiency also at partial load. The relevant valve management software is also embedded in the unit's VertivTM ICOMTM control function.
VertivTM ICOMTM Control - When Smart Means Efficient Smart mode is a control algorithm developed for Vertiv SmartAisleTM containment applications, meeting the cooling and airflow needs of the servers while ensuring only necessary kilowatts are invested in targeted cooling.

Freecooling Modes for Optimizing System Efficiency yyFresh Air/Direct Freecooling yyWater/Indirect Freecooling yyLiebert EconoPhaseTM Pumped
Refrigerant Economizer.
Liebert EconoPhase Economizer

Liebert MC Microchannel Condenser
Liebert PDX Floor-Mount Unit

The Liebert EconoPhase pumped refrigerant economizer is compatible with the Liebert PDX and Liebert MC to improve thermal management and control, while drastically cutting energy costs and lowering pPUE.

4

Liebert® MC: The New Condensing Technology

Liebert® MC new microchannel condensers are ideally designed to match the outstanding performances of Liebert PDX. The highly efficient Liebert MC unit directly communicates with Liebert PDX units via the integrated VertivTM ICOMTM Control, providing significant advantages in terms of condenser management. The Liebert MC can thus be managed through the Liebert PDX Vertiv ICOM control allowing the complete coordination of unit and condenser settings status and alarm conditions. The possibility of selecting silent functioning modes at defined times (i.e. during the night or the weekend), through the unit control, further ensures full operating flexibility.

High Efficiency at Full and Partial Load Conditions

Liebert MC microchannel condensers, equipped with EC fans, deliver a 20% increase in unit efficiency at full load, when compared to a standard condenser adopting the Variable Frequency Drive (VFD). Efficiency levels are further optimized at partial load where the EC Fans require a lower power input, thus reducing energy consumption and guaranteeing top-tier performances.

Power Input/Fan (Watts)

2000 1500

VFD EC Fans

1000

500

0 100%

80% 60% 40%
Fan Speed (%)

20% 0%

For specific environments in which microchannel condenser use is limited, Liebert HCR base condensers are available.

Liebert® MC: Enhancing Efficiency Levels

Microchannel Condensing Coil:
The full aluminum coil ensures enhanced efficiency levels also during
the mechanical cooling mode.

New generation EC Fans:
The new generation EC Fans guarantee the highest efficiency at full and at partial load, ensuring also extremely silent operations.

Microchannel Aluminum Coils
5

LIEBERT® PDX from 15 to 165 kW

VertivTM ICOMTM Control Drives Liebert® PDX to the Highest Efficiency Levels

The VertivTM ICOMTM device features a unique control algorithm designed to manage the operation of the Liebert® PDX units, ensuring top reliability in all conditions. Liebert PDX units with the Vertiv ICOM control graphic display, may be centrally monitored and controlled with the optional wall mounted display. The display allows access to the unit via the Network, making coordination between Liebert PDX units within the same room possible as a result of the integrated Ethernet connection. The self monitoring of redundant units alternates standby positions and gives priority to possible hot spots. The high-level supervision of multiple units allows them to work together as a single system optimizing room temperature and humidity. This is of particular importance for EC fans. EC fan power consumption

is exponential. Having five units running at 80% instead of four at 100% will lower the total energy used by the entire group by 36%. Vertiv ICOM manages the reduction of fan speed whenever operation at full capacity is not required. Liebert PDX digital modulates both fans and compressors thus increasing the entire system's efficiency. Efficiency is in turn further increased as a result of Liebert PDX's ability to share the heat load among installed units, guaranteeing ideal cooling levels while minimizing consumption.
Unit to Unit Communication Vertiv ICOM directly connects with the facility network (Ethernet) and enables communication between multiple Liebert PDX units for synchronized operation, guaranteeing increased reliability and precision cooling room control.

Smart mode is a control algorithm developed for Vertiv SmartAisleTM containment applications, meeting the exact cooling and airflow needs of the servers, investing only necessary kilowatts in targeted cooling.

6

Liebert® PDX: Remote Diagnostic and Preventive Monitoring Services

VertivTM LIFETM Services Remote Diagnostic and Preventive Monitoring Proactive equipment maintenance reduces downtime and extends equipment life which in turn maximizes return on investment and increases system availability. Vertiv supports entire critical infrastructures with an extensive service offering, guaranteeing network availability and total peace of mind 24/7. Our approach to servicing critical infrastructure covers all aspects of availability and performance, from single units to entire mission critical systems, providing customers with tailored services to meet their individual business needs. Vertiv's service program is designed to ensure that your critical Thermal Management system is maintained in an optimum state of readiness at all times. Vertiv LIFE Services enable 24/7 Remote Diagnostic and Preventive Monitoring providing early warning of Thermal Management units conditions and out of tolerances. This allows proactive maintenance and remote trouble shooting minimizing the risk of downtime and optimizing Mean Time Between Failures and First Time Fix Rate, granting total peace of mind. Basic Web Access Basic operational information can be made available through the monitoring feature offered by the Vertiv ICOMTM Control over Ethernet. A web browser is the only requirement needed for the unit to communicate directly with the local or remote web interface.
Basic Web Access

Monitoring and Control Through Existing Network Via your Web Browser The Liebert® PDX system can be fitted with a Vertiv IntelliSlot® Unity Card allowing full advantage to be taken of the Ethernet network and remote monitoring from your computer desktop, network operations center or any network access simply utilizing a standard web browser. A standard web browser, via HTTP protocol or Network Management System software via SNMP protocol, can be used to access the unit information.
Monitoring Integration with Existing Building Management System If required, Liebert PDX may be integrated with an existing Building Management System, while the Vertiv IntelliSlot Unity Card provides Modbus RTU and Modbus TCP compatibility. SCADA support is completed through the Bacnet over IP card.
Vertiv NformTM Software Centralized Management As business grows, critical equipment infrastructure expands, thus the need for centralized management of any equipment is key to business success. Connecting to equipment in the distributed critical space is only part of the monitoring challenge. Vertiv Nform leverages the network connectivity capabilities of Liebert PDX to provide centralized monitoring of the distributed equipment. Utilizing the SNMP and Web
Vertiv SiteScan Web Control, Data Capture, Energy Management and Planning

technologies integrated in the IntelliSlot communication card, Vertiv Nform centrally manages alarm notifications and provides an intuitive interface to access critical status information. Vertiv Nform allows critical system information to be readily available to support personnel wherever they are, increasing responsiveness to alarm-event conditions, thus allowing IT organizations to maximize their system availability.
Vertiv SiteScan® Web Control, Data Capture, Energy Management and Planning
For customers who require extensive management of critical system equipment spanning multiple locations in an evermoving global enterprise, Vertiv SiteScan Web will centrally manage critical equipment and give the power to move beyond the event responsive service paradigm.
Vertiv SiteScan Web does it all yyReal-Time Monitoring and
Control yyEvent Management and
Reporting yyData Analysis and Trending yyBuilding Management
Integration.
Vertiv SiteScan Web is a comprehensive critical system management solution dedicated to ensuring reliability through graphics, event management and data export. The standard web interface allows users easy access from anywhere, anytime.

ces

Ver

Advanced Access with Vertiv Intellislot Card

tiv LIFE Servi

Monitoring and Alarm Notification through Vertiv Nform

7

LIEBERT® PDX from 15 to 165 kW

Liebert® PDX - Scroll Specifications

SINGLE CIRCUIT Model

Total Gross Cooling Capacity

kW

Net Sensible Cooling Capacity

kW

SHR

Net Sensible EER

Airflow

m3/h

Max. ESP

Pa

Dimensions (W x D)

mm

Height (H)

mm

Weight

kg

Number of Capacity Steps

Aiflow Delivery Down Flow UP - Fans Over the Raised Floor

Up Flow

Frontal

Downflow Down - Fans in Raised Floor

PX015 13.9 13.4 1.00 4.37 4462 250
844 x890 1970 290 1

PX021 19.1 18.2 1.00 3.93 5672 250
844 x 890 1970 300 1

PX025 25.0 23.2 0.98 3.53 6792 250
844 x 890 1970 320 1

PX031 30.1 26.5 0.94 3.21 7752 220
844 x 890 1970 340 1

PX033 34.2 28.7 0.90 3.09 7944 180
844 x 890 1970 340 1

PX041 PX045 PX059 PX047 PX051 PX057

40.41

44.6

57.3

46.28

53.1

59.0

35.8

39.1

45.1

43.8

50.0

54.6

0.93

0.93

0.82

1.00

1.00

0.98

3.51

3.33

2.99

3.70

3.47

3.40

10000

10900

11200

14500

15800

16300

250

100

80

300

300

300

1200 x 890 1200 x 890 1200 x 890 1750 x 890 1750 x 890 1750 x 890

1970

1970

2570

1970

1970

1970

452

456

803

620

621

675

1

1

2

1

1

2

Cooling Version: Air Cooled
Water Cooled

Dual fluid (Chilled water + DX Air Cooled) Dual fluid - Chilled water + DX Water Cooled Freecooling EconoPhase

DOUBLE CIRCUITS

Model

Total Gross Cooling Capacity

kW

Net Sensible Cooling Capacity

kW

SHR

Net Sensible EER

Airflow

m3/h

Max. ESP

Pa

Dimensions (W x D)

mm

Height (H)

mm

Weight

kg

Number of Capacity Steps

Aiflow Delivery Down Flow UP - Fans Over the Raised Floor

Up Flow

PX044 44.8 42.3 0.99 3.79 12500 300
1750 x 890 1970 638 2

Frontal Downflow Down - Fans in Raised Floor

Cooling Version: Air Cooled
Water Cooled

Dual fluid (Chilled water + DX Air Cooled) Dual fluid - Chilled water + DX Water Cooled Freecooling EconoPhase

PX054 55.1 51.2 0.99 3.53 15500 200
1750 x 890 1970 642 2

PX062 62.5 55.6 0.95 3.35 16300 200
1750 x 890 1970 680 2

PX068 66.1 62.2 0.98 4.08 18500 300
2550 x 890 1970 887 2

PX074 74.8 62.9 0.90 3.09 17600 80
1750 x 890 1970 680 2

PX092 92.5 72.2 0.82 2.93 17950 180
1750 x 890 2570 986 2

PX082 85.7 78.4 0.97 3.60 24000 250
2550 x 890 1970 901 2

PX094 94.5 84.9 0.96 3.38 26000 150
2550 x 890 1970 901 2

PX104 PX120

106.5

123.9

91.7

100.7

0.92

0.86

3.10

2.95

27000

27000

100

100

2550 x 890 2550 x 890

1970

1970

901

954

2

4

Performances at 24°C 50% - 45°C condensing temperature - Nominal ESP 20 Pa

8

Liebert® PDX - Digital Scroll - VertivTM SmartAisleTM

SINGLE CIRCUIT

Model

Total Gross Cooling Capacity

kW

Net Sensible Cooling Capacity

kW

SHR

Net Sensible EER

Airflow

m3/h

Max. ESP

Pa

Dimensions (W x D)

mm

Height (H)

mm

Weight

kg

Minimum Nominal Capacity Modulation

Aiflow Delivery

Down Flow UP - Fans Over the Raised Floor

Up Flow

Frontal

Downflow Down - Fans in Raised Floor

Cooling Version: Air Cooled

Water Cooled

Dual fluid (Chilled water + DX Air Cooled) Dual fluid - Chilled water + DX Water Cooled

Freecooling

EconoPhase

PX021 24.9 24.1 1.00 4.79 5672 250
844 x890 1970 300 20%

PX025 32.4 31.1 1.00 4.65 6792 250
844 x 890 1970 320 20%

PX031 37.8 36.0 0.98 4.24 7752 230
845 x 890 1970 340 20%

PX033 41.9 39.9 0.94 4.18 7944 200
844 x 890 1970 340 20%

PX041 50.3 48.4 0.90 4.62 10000 250
1200 x 890 1970 452 20%

PX045 55.4 53.0 0.93 4.36 10900 100
1200 x 890 1970 456 20%

PX059 68.8 66.4 0.93 4.35 11200 80
1200 x 890 2570 803 25%

PX047 63.0 60.5 1.00 4.58 14500 300
1750 x 890 1970 635 25%

PX051 67.4 64.3 1.00 4.53 15800 300
1750 x 890 1970 637 25%

PX057 74.6 71.3 1.00 4.37 16300 300
1750 x 890 1970 675 25%

DOUBLE CIRCUITS

Model

PX044 PX054 PX062 PX068 PX074 PX092 PX082 PX094 PX104 PX120 PX150 PX165

Total Gross Cooling Capacity

kW

61.0

72.8

80.4

90.1

94.5

113.3

111.8

126.3

133.4

153.4

199.1

228.1

Net Sensible Cooling Capacity

kW

59.0

69.3

76.6

87.5

89.8

109.3

106.6

120.1

126.5

146.5

190.8

214.1

SHR

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

1.00

Net Sensible EER

5.19

4.80

3.28

5.60

4.34

4.38

4.46

4.33

4.35

4.22

4.27

3.82

Airflow

m3/h 12500 15500 16300 18500 17600 17950 24000 26000 27000 27000 34585 42500

Max. ESP

Pa

300

200

200

300

80

180

250

150

100

100

300

160

Dimensions (W x D)

mm 1750 x 890 1750 x 890 1750 x 890 2550 x 890 1750 x 890 1750 x 890 2550 x 890 2550 x 890 2550 x 890 2550 x 890 3350 x 890 3350 x 890

Height (H)

mm

1970

1970

1970

1970

1970

2570

1970

1970

1970

1970

2570

2570

Weight

kg

638

642

680

887

680

986

931

931

931

954

1485

1485

Minimum Nominal Capacity Modulation

10%

10%

10%

10%

10%

10%

12.5%

12.5%

12.5%

12.5%

12.5%

12.5%

Aiflow Delivery Down Flow UP - Fans Over the Raised Floor

Up Flow

Frontal

Downflow Down - Fans in Raised Floor

Cooling Version: Air Cooled

Water Cooled

Dual fluid (Chilled water + DX Air Cooled)

Dual fluid - Chilled water + DX Water Cooled

Freecooling

EconoPhase

Performances at 37°C 24% - 45°C condensing temperature - Nominal ESP 20 Pa - Fan over the floor

9

LIEBERT® PDX from 15 to 165 kW Thermal Management Data Center Infrastructure for Small and Large Applications

Liebert® HPC
Wide range of high efficiency Freecooling Chillers from 40 kW to 1600 kW
yy Designed specifically for data center applications and to work with VertivTM SmartAisleTM
yy Premium energy efficiency version yy Unique control capabilities with the Vertiv
ICOMTM Control.
Liebert PDX Liebert PCW
Available from 5-220 kW
yy Premium energy efficiency
yy Eurovent certified performance
yy Unique control capabilities with the Vertiv ICOM Control
yy Liebert® EconoPhaseTM available for the direct expansion system.

Liebert EFC
Indirect evaporative freecooling unit leveraging on data center know-how. Available from 100 to 450 kW
yy Unique control capabilities optimizing water and energy costs
yy Substantial reductions and savings in terms of electrical infrastructure.

VertivTM TrellisTM Platform
Vertiv's TrellisTM platform is a real-time infrastructure optimization platform that enables the unified management of data centre IT and facilities infrastructure. The Vertiv Trellis platform software can manage capacity, track inventory, plan changes, visualize configurations, analyze and calculate energy usage, and optimize cooling and power equipment. The Vertiv Trellis platform monitors the data center, providing a thorough understanding of system dependencies to help IT and facilities organizations keep the data center running at peak performance. This unified and complete solution, delivers the power to see the real situation in your data center, make the right decision and take action with confidence.

10

Liebert AFC
The Adiabatic Freecooling Chiller available from 500-1450 kW yy Integrated adiabatic pad system yy High freecooling capacity yy 100% compressor back up.
VertivTM SmartAisleTM
yy Aisle containment yy Provides highest energy
efficiency yy Works with any Liebert
Thermal Management unit.
Liebert CRV
Row-based high efficiency cooling units available from 10-60 kW in DX and CW versions yy Full airflow and cooling capacity modulation to
match server load and to save energy yy Best footprint capacity with the highest
efficiency yy Six different control modes to ensure greater
flexibility.
Liebert DCL
Closed loop rack cooling yy Two different architectures:
Closed Loop Hybrid Loop yy Multiple combinations for up to 4 server racks yy Dual CW coil version for redundancy.

SERVICES
Vertiv supports entire critical infrastructures with the largest global service organization and an extensive service offering, enhancing network availability and ensuring total peace of mind 24/7. Our approach to servicing critical infrastructure covers all aspects of availability and performance: from single power and thermal management equipment to entire mission-critical systems. The most comprehensive insurance for business protection can be obtained with a service program from Vertiv which includes access to Vertiv LIFETM Services.
VERTIVTM LIFETM SERVICES
Vertiv LIFE Services provides Remote Diagnostics and Preventive Monitoring for UPS and thermal management equipment. Vertiv LIFE Services delivers increased uptime and operational efficiency by enabling continuous monitoring of your equipment, expert data analysis and field engineering expertise. Through the data transferred from your equipment via Vertiv LIFE Services, our Remote experts gain the real-time insight and information needed to quickly identify, diagnose, and resolve any irregularities that may arise in operation, ultimately taking responsibility for your critical assets 24/7.
11

VertivCo.eu | Vertiv Infrastructure Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827
© 2018 Vertiv Co. All rights reserved. VertivTM, the Vertiv logo, Liebert® PDX, Liebert EC Fan 2.0, Liebert EconoPhaseTM, Liebert MC, Liebert HPC, Liebert PCW, Liebert AFC, Liebert EFC, Liebert CRV, Liebert XD, Vertiv TrellisTM, Vertiv Intellislot®, Vertiv SiteScan®, Vertiv ICOMTM, Vertiv SmartAisleTM, Vertiv NformTM and Vertiv LIFETM Services are trademarks or registered trademarks of Liebert Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Liebert Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.
MKA4L0UKPDX Rev. 5-04/2018


Neevia Converter Pro v6.8 (http://neevia.com)