Yale Digital Door Lock User Guide YDM4109+
MUST READ
- This Product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications.
- All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
- This product (YDM4109+) is a Security Enabled Z-Wave Plus Product.
- Security Enabled Z-Wave Controller must be used in order to fully utilize this product.
- Network Module Setting: This setting becomes available through the Main Menu and allows the lock to connect with Controllers.
Reset locally: Z-Wave Module exclusion
Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Action | Steps | Result |
Add (Inclusion) | U PIN 1-9 Controller # 1 Register # Register Controller # * Continue | Complete |
Remove (Exclusion) | U PIN 3 Delete # PIN # * Continue | Complete |
Reset Locally | Reset Locally # | Complete |
Note: The door lock could be initialized by pressing of '0' key due to a mistake of user, so, '0' has not been intentionally displayed to prevent the door lock from initializing.
You can find the Security 2 DSK information on the product as shown below:
zws2dsk: 46249-42352-03523-40600-59887-53699-31945-13463 sn:U121M180700001xx
Association Command Class
Association Group
- This product supports ONE association Group.
- Group is the Lifeline Group.
- It can contain up to 1 nodes.
S2 Security CCs and security level
Command Class | Ver. | Note | Command Class | Ver. | Note |
---|---|---|---|---|---|
Alarm | 1 | Secure | Schedule Entry Lock | 3 | Secure |
Association | 2 | Secure | Security | 1 | Non Secure |
Association Group Info | 1 | Secure | Security 2 | 1 | Non Secure |
Battery | 1 | Secure | Supervision | 1 | Non Secure |
Configuration | 1 | Secure | Time | 2 | Non Secure |
Device Reset Locally | 1 | Secure | Time Parameter | 1 | Secure |
Door Lock | 2 | Secure | Transport Service | 2 | Non Secure |
Door Lock Logging | 1 | Secure | User Code | 1 | Secure |
Manufacturer Specific | 2 | Secure | Version | 2 | Secure |
Powerlevel | 1 | Secure | Z-Wave Plus Info | 2 | Non Secure |
Configuration Command Class
Set the language of the Door Lock interface
Usage | Parameter Number | Size | Value | Description |
---|---|---|---|---|
Set Language | 0x05 | 1 byte | 0x01 | Korean |
0x02 | English | |||
0x03 | Chinese | |||
0x06 | Taiwanese |
Front body
(Front Body, Installation on the outside of the door)
Components:
- 1: Fingerprint Operation Lamp
- 2: Keypad (10-Key)
- 3: Dead Bolt Jam Lamp
- 4: Lever
- 5: Fingerprint Cover
- 6: Battery Change Lamp
- 7: Reset button
- 8: Emergency Key
- 9: Emergency Power Supply Terminal
- 10: Emergency Cover
Pull down Emergency Cover:
The diagram shows the emergency cover being pulled down, revealing the reset button (7), emergency keyhole (8), and emergency power supply terminal (9). A 9V emergency battery is optional.
Main body
(Main Body, Installation on the inside of the door)
Components:
- 1: Battery Cover
- 2: Registration button
- 3: Lever
- 4: Manual thumb turn
- 5: Internal Forced Lock Switch
- 6: 1.5V AA Alkaline Batteries (4EA)
- 7: Slot for Remote control module (Option)
- 8: Volume Control Switch
- 9: Auto / Manual Lock button
- 10: Safe handle button
The diagram illustrates the main body of the lock, including the battery compartment, various buttons and switches, and its connection to the lock case.
Register Controller
Procedure:
- Enter Master Code.
- Press the [I] button.
- Enter [9], [#] buttons.
- Enter [1], [#] buttons to register controller.
- Register Controller followed by press [#] button to complete after beep sound from digital door lock.
- Press [*] button to continue.
- Press [I] button to complete.
Alternative completion: Press [I] button to complete.
Delete Controller
Procedure:
M PIN 1-9 Controller # 3 Delete # PIN Master Code # * Continue
Complete
Resetting Lock to Factory Default
When the lock is reset to factory defaults, all user codes (including the Master Code) are deleted, and all programming features are reset to original default settings.
- Remove the battery cover and batteries.
- Remove the interior escutcheon to access the reset pads.
- The reset pads are located on the bottom of the PCB board.
- While pressing the reset pads with tweezers, reinstall batteries and release reset pads with tweezers.
- Replace the battery cover.
Upon reset, the Master Code creation is the only option available and must be performed prior to any other programming of the lock.
The diagram shows the location of the reset button on the PCB board.
User Code Registration (4~10 digits)
Procedure:
- Press the [I] button.
- Enter New User Code.
- Press the [I] button to complete.
User Fingerprint Registration (Up to 20ea)
Procedure:
- Press the [I] button.
- After opening the cover, swipe your finger 3 times through the fingerprint sensor, followed by the voice guide.
- Press [*] button to continue.
- Press [I] button to complete.
Unlocking Door with Code
Procedure:
- Touch the keypad of the Front Body with your palm.
- Enter the registered Code on the keypad.
- Touch the keypad of the Front Body with your palm.
- Enter the [*] button.
Unlocking Door with Card Key
Procedure:
- Contact registered Card Key.
Related Documents
![]() | Z-Wave Protocol Implementation Conformance Statement - Keyfree Connected This document details the Z-Wave protocol implementation conformance for the Keyfree Connected device by Yale. It includes general information, product features, Z-Wave specific technical details, and supported command classes. |
![]() | Yale YDM3115V Z-Wave Protocol Implementation Conformance Statement This document details the Z-Wave protocol implementation conformance statement for the Yale YDM3115V smart lock, including general information, product features, Z-Wave product information, technical specifications, and association group information. |
![]() | Yale Pro® 2 Lock SL Key Free Touchscreen Deadbolt - Z-Wave Protocol Implementation Conformance Statement This document provides the Z-Wave Protocol Implementation Conformance Statement for the Yale Pro® 2 Lock SL Key Free Touchscreen Deadbolt, detailing its Z-Wave features, technical specifications, and supported command classes. |
![]() | Yale Assure Lock Z-Wave Conformance Statement Official Z-Wave Protocol Implementation Conformance Statement for the Yale Real Living Assure Lock, detailing its features, technical specifications, and Z-Wave compatibility. |
![]() | Z-Wave Conformance Statement: Yale Assure Lock for Andersen Patio Doors Official Z-Wave protocol implementation conformance statement for the Yale Assure Lock for Andersen Patio Doors (YRM276-ZW2), detailing product features, technical specifications, and Z-Wave network capabilities. |
![]() | Yale Real Living Assure Lock SL Key Free Touchscreen Deadbolt - Z-Wave Conformance Statement Technical conformance statement for the Yale Real Living Assure Lock SL Key Free Touchscreen Deadbolt (YRD256-ZW2), detailing its Z-Wave protocol implementation, features, and technical specifications. |
![]() | Yale Z-Wave Enabled Keyless Deadbolt - Z-Wave Conformance Statement This document details the Z-Wave Protocol Implementation Conformance Statement for the Yale Z-Wave Enabled Keyless Deadbolt (YRD642-ZW2), including product features, Z-Wave technical information, and supported command classes. |
![]() | Yale ProSL Key Free Keypad Deadbolt with Z-Wave Plus: Installation and Programming Guide Comprehensive guide for installing and programming the Yale ProSL Key Free Keypad Deadbolt with Z-Wave Plus. Covers door preparation, lock assembly, PIN code management, Z-Wave setup, and troubleshooting. |