LG LSN120HSV5 Multi F Wall Mounted High Efficiency Indoor Unit
12,000 Btu/h
Performance
- Nominal Cooling Capacity: 12,000 Btu/h
- Nominal Heating Capacity: 13,600 Btu/h
- Cooling Nominal Test Conditions: Indoor 80°F DB / 67°F WB, Outdoor 95°F DB / 75°F WB
- Heating Nominal Test Conditions: Indoor 70°F DB / 60°F WB, Outdoor 47°F DB / 43°F WB
Electrical
- Power Supply: 208-230/60/1 V/Hz/Ø
- Rated Amps: 0.4 A
Piping
- Installed Liquid Pipe (in., O.D.): 1/4
- Installed Vapor Pipe (in., O.D.): 3/8
- Liquid Connection (in., O.D.): 1/4
- Vapor Connection (in., O.D.): 3/8
- Drain (in., O.D. / I.D.): 27/32, 5/8
- Temperature Sensor: Thermistor
Controls Features
- 4-Way auto swing
- 24-Hour on/off timer
- Auto operation
- Auto restart
- Chaos wind
- Inverter (variable speed fan)
- Jet cool/Jet heat
- 3M Micro Dust Filter
- Self-cleaning indoor coil
- Sleep mode
- Condensate sensor connection
- Built-in Wi-Fi via Smart ThinQ app
- Compatible with Single Zone HSV5 Outdoor Units
Included Accessories
- Wireless Remote Controller - AKB74955602
Optional Accessories
- MultiSITE™ CRC1 - PREMTBVCO
- MultiSITE CRC1+ - PREMTBVC1
- Dry Contact - PDRYCB300
Unit Data
- Refrigerant Type: R410A
- Refrigerant Control: EEV
- Sound Pressure (H/M/L) (±3 dB[A]): 38/34/29
- Primary Filter: Washable Pre-filter
- Secondary Filter: 3M Micro Dust
- Net Weight (lbs.): 18.3
- Shipping Weight (lbs.): 23.4
Fan
- Type: Cross Flow
- Quantity: 1
- Motor/Drive: Brushless Digitally Controlled/Direct
- Air Flow H/M/L (CFM): 282/233/177
Entering Mixed Air
- Cooling (°F WB): 57~77
- Heating (°F DB): 59~81
Notes
- Acceptable operating voltage: 187V-253V.
- Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
- See Engineering Manual for sensible and latent capacities.
- All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and must be a minimum of four-conductor, 18 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
- Power wiring cable size must comply with the applicable local and national code.
- The indoor unit comes with a dry helium charge.
- Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratio between 95-105%.
- Must follow installation instructions in the applicable LG installation manual.
Dimensions and Installation
Diagrams show unit outline, air intake and outlet holes, and piping/cable routing. Key dimensions are provided in inches (mm).
- Unit Outline Dimensions: Varying dimensions provided for width, height, and depth, with specific callouts for air outlet and intake holes.
- Installation Plate: Details on fixing the installation plate and drilling holes.
- Piping Connections: Specifications for refrigerant pipe connections (liquid and vapor) and drain hose connection.
- Airflow Direction Control: Notes on Up & Down, Left, and Right airflow adjustments.