S-A Q120DFP BRKR QFGA2 AFCI/GFCI 1P | Irby
Molded Case Circuit Breakers SPEEDFAXTM 7 Section Dual Function Circuit Breaker 3VA41 1-pole QR Circuit Breakers 3VA molded case circuit breakers Scan to connect online to the most up-todate version of this Section of SPEEDFAX. (Section was last modified on 02/15/22) contents What's New in Circuit Breakers 7-3 7-4 Federal Specifications Classification 7-5 Reference Guides 7-6 7-18 Load Center Breakers Arc Fault and Ground Fault Breakers 7-19 QP, 1 Inch Breakers 7-20 QT, ½ Inch Breakers 7-21 Special Application Breakers 7-22 QD ¾ Inch Breakers 7-23 Main and Branch Breakers 7-24 7-25 Circuit Breaker Dimension Drawings 7-26 Circuit Breaker Lug Data 7-27 Surge Protection 7-28 Panelboard Mounted Circuit Breakers BL 240V Breakers 7-29 BL 240V Arc Fault and Ground Fault Breakers 7-30 Special Application 240V Panelboard Mounted Breakers 7-31 BQD 100A Frame 480/277V Breakers 7-32 GB 125A Frame 600/347V Breakers 7-33 NGB2 125A Frame 600/347V Breakers 7-34 Internal Accessories for BQD and NGB Breakers 7-35 3VA41 125A Frame 600/347V Breakers 7-36 7-37 General Application Circuit Breakers BQ 240V Breakers 7-38 BQXD 240V DIN Rail Mounting Breakers 7-39 QR250 Frame 240V Breakers 7-40 CQD 100A Frame 480/277V Breakers 7-42 GG 125A Frame 600/347V Breakers 7-43 Internal Accessories for CQD and NGG Breakers 7-44 3VA Molded Case Circuit Breakers Catalog Numbering System 7-46 3VA41 125A Frame 600/347V Breakers 7-48 7-49 3VA51 125A Thermal-magnetic Trip Circuit Breakers 7-50 7-54 3VA61 150A Electronic Trip Circuit Breakers 7-55 7-57 3VA52 250A Thermal-magnetic Trip Circuit Breakers 7-58 7-61 3VA62 250A Electronic Trip Circuit Breakers 7-62 7-65 3VA53 400A Thermal-magnetic Trip Circuit Breakers 7-66 7-67 3VA63 400A Electronic Trip Circuit Breakers 7-68 7-70 3VA54 600A Thermal-magnetic Trip Circuit Breakers 7-71 3VA64 600A Electronic Trip Circuit Breakers 7-72 7-74 3VA55 800A Thermal-magnetic Trip Circuit Breakers 7-75 3VA65 800A Electronic Trip Circuit Breakers 7-76 7-77 3VA66 1000A Electronic Trip Circuit Breakers 7-79 7-80 3VA Molded Case Switch and Motor Circuit Protector 7-81 7-82 3VA Internal Accessories 7-83 3VA Breaker Operators 7-84 7-89 3VA Connection Technology 7-91 7-99 3VA Plug-in and Draw-out Technology 7-100 7-102 3VA Communication and Testing/Commissioning Devices 7-103 7-106 3VA Accessories and Electrical Requirements 7-107 7-112 (continued on next page) Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-1 MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers SPEEDFAXTM contents Sentron Thermal Magnetic and Electronic Circuit Breakers Catalog Numbering System ED 125A Frame 600V Breakers and Internal Accessories FD 250A Frame 600V Breakers and Internal Accessories JD/SJD 400A Frame Breakers and Internal Accessories LD/SLD 600A Frame Breakers and Internal Accessories LMD 800A Frame Breakers and Internal Accessories MD/SMD 800A Frame Breakers and Internal Accessories ND/SND 1200A Frame Breakers and Internal Accessories PD/SPD 1600A Frame Breakers and Internal Accessories RD 2000A Frame Breakers and Internal Accessories Magnetic Trip Only ETI Motor Circuit Protectors Adjustable Instantaneous Magnetic Trip Settings Molded Case Switch Circuit Disconnect Digital Solid State Sentron Sensitrip IV Series Trip Units WL Power Circuit Breakers Lug Information Breaker Modifications Internal Accessories Feature Combinations External Accessories Unusual Operating Conditions VL Thermal Magnetic and Electronic Circuit Breakers Catalog Numbering System Technical Overview Trip Unit Overview DG 150A Frame and Internal Accessories FG 250A Frame and Internal Accessories JG 400A Frame and Internal Accessories LG 600A Frame and Internal Accessories MG 800A Frame and Internal Accessories NG 1200A Frame and Internal Accessories PG 1600A Frame and Internal Accessories Molded Case Switch Motor Circuit Protector VL 600 Volt DC Circuit Breakers External Accessories Accessory Locations Suffix for Factory Mounted Internal Accessories Technical Data Unusual Operating Conditions General Technical Series Short Circuit Ratings Sentron IEC 94702 AC Interrupting Ratings Typical Specifications Superseded Circuit Breakers 7-113 7-114 7-116 7-117 7-119 7-120 7-123 7-124 7-127 7-128 7-130 7-131 7-134 7-135 7-138 7-139 7-141 7-142 7-143 7-145 7-146 7-148 7-149 7-150 7-151 7-152 7-155 7-156 7-158 7-159 7-160 7-163 7-168 7-169 7-170 7-171 7-172 7-173 7-174 7-175 7-176 7-177 7-180 7-181 7-184 7-185 7-188 7-189 7-192 7-193 7-196 7-197 7-200 7-201 7-203 7-204 7-205 7-206 7-207 7-219 7-220 7-221 7-222 7-223 7-224 7-225 7-226 7-236 7-237 7-238 7-239 7-241 7 Section Sentron Sensitrip MOLDED CASE 7 CIRCUIT BREAKERS 7-2 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Revised on 07/31/21 Introduction What's new in molded case circuit breakers: New Sentron Sensitrip Sentron Sensitrip IV ETU Circuit Breakers with Integrated DAS / Maintenance Mode Design enhancements include: n Upgraded ETU for NEC 240.87 code compliance (Arc Energy Reduction) n Frame ratings from 400A to 1600A n Identical footprint, kAIC ratings and accessory offering as legacy Sensitrip III ETU breakers to ease integration / retrofit n Maintenance mode versions require customer-supplied 24V external power supply, maintenance switch and light The New Siemens QR Circuit Breaker Implemented in load centers, panelboards, switchboards, meter centers, and modular metering, the new QR breaker is the same form-factor/ mounting as QJ breaker for easy retrofit. Design enhancements include: n Trip unit ratings from 100A to 250A. n Field installable internal accessories shunt trip, aux switch or shunt/aux combo. n Two accessory pockets in 3-pole breakers. One accessory pocket in 2-pole breakers. n High in-rush current capability (450%). n Push-to-trip button. The Dual Function Circuit Breaker combines GFCI and AFCI, protecting against both Arc Faults and Ground Faults. This, along with the new Self-Test & Lockout feature, makes it the first in class in electrical safety for homeowners. n Faster Installation n Cost savings n Smaller Device n Self Test & Lockout feature as required by UL 943 effective June 2015 The new Siemens 3VA molded case circuit breakers n 125A thru 800A Thermal Magnetic Trip breakers n 150A thru 1000A Electronic Trip Circuit Breakers n Extensive and flexible accessories n Common internal accessories for the entire breaker family n Power metering with the series-8 LCD electronic trip n Illuminated rotary handles show switch position n Smaller footprint than Sentron or VL breakers n Enhanced Tools and Resources MOLDED CASE 7 CIRCUIT BREAKERS The Siemens 3VA41 circuit breaker is a compact, industrial design thermal magnetic breaker with features which include a design that meets multinational standards (UL, NOM, EAC), available with NAVAL ratings which meet UL489 Supplement SB, and an extensive selection of UL listed, field installable internal accessories (auxillary and alarm switches, shunt and undervoltage trips). The 3VA41 is available from 15A to 125A in 1, 1 in 2-pole, 2 or 3-pole versions on 1 inch pole centers having AC interrupting ratings up to 65KA @ 480VAC and 25KA @ 600Y347V and DC ratings up to 100KA @ 250VDC. 1-Pole 1 in 2-Pole 2-Pole 3-Pole Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-3 Molded Case Circuit Breakers Ordering The 3VA breakers are shipped complete with non-interchangeable trip units and without lugs. The 3VA41 panelboard mounted circuit breakers are shipped with aluminum load side lugs installed as standard. 3VA51 through 3VA55 thermalmagnetic trip breakers as well as 3VA61 through 3VA66 electronic trip breakers are shipped as standard without lugs installed. To order factory installed nut keepers, which are required for installation in panelboards or switchboards, the 12th digit of the catalog should be change to "2" when ordering. (For example, a 35KA@480VAC, 40A, 3-pole, 3VA51 with lugs would be catalog number 3VA5140-5ED32-0AA0). To order factory installed standard line and load lugs, the 12th digit of the catalog number should be changed to "6" (standard lugs are identified in the respective lug tables and footnotes in the SpeedFax). (For example, a 35KA@480VAC, 40A, 3-pole, 3VA51 with lugs would be catalog number 3VA5140-5ED36-0AA0). Alternate connectors can be ordered separately for field installation. All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked "NAVAL", and are suitable for use at 50C. To order NAVAL-rated thermal-magnetic trip circuit breakers, the 13th digit of the catalog number should be changed to the number "1". (For example, a 35KA @480VAC, 40A, 3-pole, NAVAL rated 3VA51 would be catalog number 3VA5140-5ED31-1AA0). All 3VA5 thermal-magnetic trip and 3VA6 electronic trip circuit breakers are UL listed for reverse feed applications. 500V DC Wiring Configuration Connecting Breakers for DC Application Most Siemens thermal magnetic trip MCCBs are applicable on direct current (dc) systems. Generally, for 250 V dc systems a two pole breaker is used, with one pole on each leg of the supply circuit. For three pole breakers applied on 500 V undergrounded DC systems, it is important to connect the power supply "zig-zag" through the breaker as shown in the figure below. This assures that the Voltage between phases on the breaker terminals is uniformly distributed. See below for an alternative connection diagram. For a list of 3VA5 breakers with the DC ratings, please refer to pages 7-10 to 7-11. 300 V MAX. 300 V MAX. Load/Carga/ Charge Revised on 07/31/21 Introduction MOLDED CASE 7 CIRCUIT BREAKERS 7-4 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Revised on 04/30/21 Federal Specification Classification Reference W-C-375C/GEN Class 10ab 10b 11a 11b 12ab 12b 12c 13a 13b 14a 14b 15a Interrupting Rating Symmetrical Amperesa Volts AC 60HZ 5,000 5,000 7,500 7,500 10,000 10,000 10,000 14,000 14,000 22,000 22,000 65,000 120/240 240 120 240 120/240 240 277 277 277/480 120/240 240 120/240 15b 65,000 240 16a 100,000 480 16b 100,000 600 17a 200,000 600 18,000 240 18a 14,000 480 14,000 600 22,000 240 19a 18,000 480 14,000 600 25,000 240 20a 22,000 480 22,000 600 Poles 1 or 2 2 or 3 1 2 or 3 1 or 2 2 or 3 1 1 1, 2, or 3 1 or 2 2 or 3 1 or 2 2 or 3 2 or 3 2 or 3 2 or 3 2 or 3 2 or 3 2 or 3 42,000 240 21a 30,000 480 22,000 600 2 or 3 65,000 240 22a 25,000 480 18,000 600 2 or 3 65,000 240 23a 35,000 480 25,000 600 2 or 3 65,000 240 24a 50,000 480 42,000 600 125,000 240 25a 80,000 480 60,000 600 2 or 3 2 or 3 Range of Current Tripc 15100 15100 15100 15100 15100 15225 15100 15100 15100 15100 70400 15100 15225 15225 15600 702000 Breaker Type (All Circuit Breakers Meet or Exceed the Indicated Class Level) QP, BQ, QT, BL, BTd QP, BQ, BQD, CQD, BL QP, BQ, BQD, CQD, BL QP, BQ, BQD, CQD, BL QP, BQ, QT, ED2, BL, BTd QP, BQ, QJ2, ED2, BQD, CQD, BL bqd, cqd, NGG, NGB, NEG, NEB ed4, bqd, cqd, NGG, NGB, NEG, NEB ed4, bqd, cqd qph, bqh, blh, BTHd qjh2, qj2-h, bqh, bqd, cqd, blh hqp, hbq, ed4, hed4, NGG, NGB ed6, ed4, fxd6, fd6, hed4, bqd, cqd, hqj2h, NGG, NGB, NEG, NEB cfd6, ced6 ced6, cfd6, cjd6, scjd6, cld6, scld6 -- 15125 ed6, hed6, hhed6 70225 fxd6, fd6, cfd6, hfd6 70225 70800 15125 701200 12002000 6004000 fxd6-a, fd6-a, cfd6, hfd6 hfd6, cfd6, jxd6(A), JD6(A), SJD6-B, hjd(a), hjxd6(a), hhjd6, SHJD6-B, cjd6, SCJD6-B, lxd6(a), ld6(a), SLD6-B, hld6(a), hlxd6(a), hhld6, SLD6-B, SHLD6-B, cld6, SCLD6-B, lmd6, lmxd6, hlmd6, hlmxd6, md6, mxd6, SMD6-B, hmd6, hmxd6, SHMD6-B, cmd6, SCMD6-B ced6, ed6, hed6, hhed6, fxd6-a, fd6-a HHED6, FXD6-A, FD6-A, hfd6, hhfd6, cfd6, Jd6(a), jxd6(a), SJD6-B, hjd6(a), hjxd6(a), SHJD6-B, hhjd6, hhjxd6, cjd6, SCJD6-B, lxd6(a), ld6(a), SLD6-B, hld6(a), hlxd6(a), SHLD6-B, hhld6, hhlxd6, cld6, SCLD6-B, lmd6, lmxd6, hlmd6, hlmxd6, md6, mxd6, SMD6-B, hmd6, hmxd6, SHMD6-B, cmd6, SCMD6-B, nd6, nxd6, snd6-B, hnd6, hnxd6, shnd6-B, cnd6, scnd6-B PD6, PXD6, HPD6, HPXD6, CPD6 RD6, RXD6, HRD6, HRXD6, SPD6-B, SHPD6-B HHLD6, CLD6, CMD6, CND6 SCLD6-B, SCMD6-B, SCND6-B, CPD6 Applicable Standards UL489 -- Molded Case Circuit Breakers and Circuit Breaker Enclosures. UL486A -- Wire Connectors and Solderless Lugs for use with copper wire Note: (A) Molded case circuit breakers are designed and tested in accordance to applicable portions of UL489 and meet application requirements of the National Electric Code. Unless marked otherwise, circuit breakers are 80% duty rated. (B) Molded case circuit breakers are to be connected with 60 or 75°C wire for circuit breakers having a rated ampacity of 100 amperes or less. Circuit breakers having a rated ampacity UL486B -- Wire Connectors and Solderless Lugs for use with aluminum wire UL943 -- Ground Fault Interrupters (for personnel protectors) UL1087 -- Molded Case Switches greater than 100 amperes shall only be cabled with 75°C cable unless otherwise indicated on the circuit breaker label. Exceptions to this rule are outlined in the article 110-14 C(1)(2) of the 2005 National Electric Code. a Interrupting ratings are not limited to the values or groups of values listed. However, the values listed are minimum values for the class specified. b Single-unit or duplex construction must be specified. UL50 -- Cabinets and Boxes UL869 -- Service Equipment NEMA AB-1 -- Molded Case Circuit Breakers and Molded Case Switches CSAC22.2 No. 5, C22.2 No. 14 c Use minimum frame size for ampere rating. d BT and BTH are only available in 15A and 20A with two 1-pole circuits in one inch of unit space. BT and BTH series breakers can be used in any Siemens panelboard in positions that accept BL or BLH series breakers. It is the installers responsibility to ensure that there is adequate neutral connections available in the panel before installing these breakers. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-5 MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers Revised on 04/30/21 Reference Guide Selection/Application Thermal-Magnetic Trip Breakers Page Dimensions in Inches Overcurrent Devices Accessories & Modifications Individual Enclosures Ratings Poles Amperes 1 Pole Volts (50/60 Hz) 2 Pole 3 Pole 120V 240V 277V 347V UL 480/277V 480V AC 600/347V Interrupt Rating Symmetrical RMS Amperes 220/ 240V IEC 947-2 50/ 60Hzi 380/ 415V 500V 600V 2-Pole lCU lCS 2, 3-Pole lCU lCS 2-Pole lCU lCS 2, 3-Pole lCU lCS 2-Pole lCU lCS 2, 3-Pole lCU lCS 2-Pole DC 125/250 V DC Interrupting Rating 3-Pole 10-50A Height 10-60A 55-125A 1-Pole Width 2-Pole 3-Pole Depth Thermal and Fixed magnetic Trip Thermal and Adjustable Magnetic trip Adjustable Magnetic trip only Motor Circuit Protector Molded Case Switch Undervoltage Trip Shunt Trip Auxilary Switch Alarm Switch Mechanical Interlock Fungus Proofing (ref. page 7-159) Type 1 - Indoor Surface Type 1 - Indoor, Flush Type 3R - Outdoor-Rainproof Plug-In Breakers QT 7-21 1, 2 15-50 QP, QPPa 7-22, 7-24 1, 2, 3 10-125 QPH, QPPHa 7-22, 7-24 1, 2, 3 10-125 HQP, HQPPa 7-20, 7-24 1, 2, 3e 10-125e HQPPHa 7-20, 7-24 2 100-225 QPJg 7-24 2, 3 150-200 120/240 120/240 120/240 120/240 120/240 120/240 -- 10,000 10,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3.12 -- 1.00 2.00 3.00 2.06 u -- -- -- -- -- -- -- -- -- -- u -- -- 240 10,000 10,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 2.87 -- 3.12 1.00 2.00 3.00 2.37 u -- -- -- ud -- ud -- -- -- -- u u u 240 22,000 22,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 2.87 -- 3.12 1.00 2.00a 3.00 2.37 u -- -- -- -- -- ud -- -- -- -- u u u 240 65,000 65,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3.12 1.00 2.00 3.00 2.37 u -- -- -- -- -- uf -- -- -- -- u u u 240 -- 100,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3.12 -- 4.00 -- 2.37 u -- -- -- -- -- uf uf -- -- -- u u u 240 -- 10,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3g -- g 3.00g 2.34 u -- -- -- -- -- -- -- -- -- -- -- -- -- Panelboard Breakers BL/BTh 7-29 1,2,3 10-125 120/240 120/240 240 10,000 10,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3.56 -- 3.75 1.00 2.00 3.00 2.37 u -- -- -- -- -- u u -- -- u BLH/BTH HBL 7-29 7-29 1,2,3 1,2,3 15-125 15-100 120/240 120/240 120/240 120/240 240 240 22,000 65,000 22,000 65,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3.56 3.75 -- -- 3.75 3.75 1.00 1.00 2.00 2.00 3.00 3.00 2.37 2.37 u u -- -- -- -- -- -- -- -- -- -- u u u u -- -- -- -- u u MOLDED CASE 7 CIRCUIT BREAKERS Q3100 B120 B220H B320HH BT For inches / millimeters conversion, see Application Data section. For Plug-in Breakers, see Load Centers & Circuit Breakers section. aTypes QPP, QPPH, HQPP and HQPPH are special 2-pole configurations for metering equipment. Amperage range = 125225A, width = 4 in. bSingle pole breakers available in ratings 1070A only. c125A, 2-pole 120/240V AC only. dNot applicable to types QPP and QPPH. e Single pole circuit breakers available in ratings 15-70A only, 125A available as a 2-pole only. f Not applicable to type HQPP and HQPPH. g Fits only Siemens EQIII load centers. Breaker is 2 or 3 poles wide. h 10A, 1-pole & 2-pole 120/240V AC only. i Applicable for 15-30A breakers only. BT and BTH are only available in 15A and 20A with two 1-pole circuits in one inch of unit space. BT and BTH series breakers can be used in any Siemens panelboard in positions that accept BL or BLH series breakers. It is the installers responsibility to ensure that there is adequate neutral connections available in the panel before installing these breakers. 7-6 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Reference Guide Thermal-Magnetic Trip Breakers Page Dimensions in Inches Overcurrent Devices Accessories & Modifications Individual Enclosures Ratings Poles Amperes Volts (50/60 Hz) 1 Pole 2 Pole 3 Pole 120V 240V 277V 347V UL 480/277V AC Interrupt Rating Symmetrical RMS Amperes 220/ 240V IEC 947-2 50/ 60Hz 380/ 415V 500V 125/250 V DC Interrupting Rating DC 125VDC Interrupting Rating 250VDC Interrupting Rating 250VDC Interrupting Rating 480V 600/347V 600V 2-Pole lCU lCS 2, 3-Pole lCU lCS 2-Pole lCU lCS 2, 3-Pole lCU lCS 2-Pole lCU lCS 2, 3-Pole lCU lCS 2-Pole 3-Pole 1-Pole 2-Pole 3-Pole 10-50A Height 10-60A 55-125A 1-Pole Width 2-Pole 3-Pole Depth Thermal and Fixed magnetic Trip Thermal and Adjustable Magnetic trip Adjustable Magnetic trip only Motor Circuit Protector Molded Case Switch Undervoltage Trip Shunt Trip Auxilary Switch Alarm Switch Mechanical Interlock Fungus Proofing (ref. page 7-159) Type 1 - Indoor Surface Type 1 - Indoor, Flush Type 3R - Outdoor-Rainproof Panelboard Breakers BQD, BQD6a 7-32 1,2,3 15-100 277 480/277 480/277 65,000 65,000 14,000 NGB NGB2b 7-33 1,2,3 15-125 347 600/347 600/347 -- 100,000 25,000 10,000 14,000 14,000 -- 25,000 -- 25,000b 10,000 -- 18,000 9,000 65,000 33,000 -- -- 18,000 9,000 -- -- -- -- 14,000 -- -- -- -- 4.50 -- 4.50 1.00 2.00 3.00 2.69 u -- -- -- -- -- u u u -- u 14,000 -- -- -- -- -- -- -- -- -- -- -- -- -- 14,000 -- -- -- -- 5.00 5.40b -- 5.00 5.40b 1.00 2.00 3.00 2.71 u -- -- -- -- -- u u u -- u HGB HGB2b 7-33 1,2,3 15-125 347 600/347 600/347 -- 100,000 35,000 14,000 22,000b 35,000 -- 35,000b 14,000 22,000b -- -- -- -- -- -- -- -- -- -- -- -- -- 14,000 -- -- -- -- 5.00 5.40b -- 5.00 5.40b 1.00 2.00 3.00 2.71 u -- -- -- -- -- u u u -- u LGB LGB2b 7-33 1,2,3 15-125 347 600/347 600/347 -- 100,000 65,000 14,000 65,000b 65,000 -- 65,000b 14,000 25,000b -- -- -- -- -- -- -- -- -- -- -- -- -- 14,000 -- -- -- -- 5.00 5.40b -- 5.00 5.40b 1.00 2.00 3.00 2.71 u -- -- -- -- -- u u u -- u Revised on 07/31/21 Selection/Application 3VA41 SEAB 7-48, 7-49 1, 2, 3 15-125 347 600/347 600/347 -- 65,000 25,000 14,000 25,000 25,000 14,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 14,000 50,000 50,000 -- -- 5.1 1.0 2.0 3.0 3.6 u -- -- -- -- 3VA41 MEAB 7-48, 7-49 1, 2, 3 15-125 347 600/347 600/347 -- 85,000 35,000 18,000 35,000 35,000 18,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 25,000 85,000 85,000 -- -- 5.1 1.0 2.0 3.0 3.6 u -- -- -- -- 3VA41 HEAB 7-48, 7-49 1, 2, 3 15-125 347 600/347 600/347 -- 150,000 65,000 25,000 65,000 65,000 25,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 30,000 100,000 100,000 -- -- 5.1 1.0 2.0 3.0 3.6 u -- -- -- -- MOLDED CASE 7 CIRCUIT BREAKERS 3VA41 125A 1-Pole For inches / millimeters conversion, see Application Data section. For Plug-in Breakers, see Load Centers & Circuit Breakers section. aBQD6 CSA certified 10,000A @ 600Y/347V 1570A only. b When two numbers are shown for the xGB/xGB2 column, the top rating is for xGB and the bottom rating for xGB2. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-7 Molded Case Circuit Breakers Revised on 11/30/19 Reference Guide Thermal-Magnetic Trip Breakers Page Poles 1-Pole Amperes, Continuous 2-Pole 3-Pole 1-Pole Volts (50/60 Hertz) 2-Pole 3-Pole 120V Ratings Interrupt Rating Symmetrical RMS Amperes UL 240V 480V 600/347V AC 1-Pole Icu 220/ Ics 240V 2,3-Pole Icu Ics IEC 947-2 50/ 60Hz 380/ 415V 1-Pole Icu Ics 2,3-Pole Icu Ics 500V 1-Pole Icu Ics 2,3-Pole Icu Ics Volts -- 2-Pole DC Interrupting Rating -- DC Amperes 1550A Height 55125A Dimensions in inches Width 60225A 1-Pole 2-Pole 3-Pole Depth Overcurrent Devices Thermal and Fixed Magnetic Trip Molded Case Switch Undervoltage Trip Shunt Trip Accessories and Auxiliary Switch Modifications Alarm Switch Mechanical Interlock Fungus Proofing (ref. page 7-159) Type 1 -- Indoor Surface Individual Enclosures Type 1 -- Indoor, Flush Type 3R -- Outdoor-Rainproof Type 5, 12 --Lint, Fine Dust, Oils, Coolants Selection/Application General Purpose Breakers BQ 7-38 1, 2, 3 1570 15125 15100 120/240 240 240 10,000 10,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3.75 4.00 -- 1.00 2.00 3.00 2.37 u u -- u u -- -- u u u u -- BQH 7-38 1, 2, 3 1570 15100 15100 120/240 240 240 22,000 22,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3.75 4.00 -- 1.00 2.00 3.00 2.37 u -- -- u u -- -- u u u u -- HBQ 7-38 1, 2, 3 1550 1570 15100 120/240 240 240 65,000 65,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 4.00 4.00 -- 1.00 2.00 3.00 2.37 u -- -- u u -- -- u u u u -- QR2 7-40 2, 3 -- 100250 100250 -- 240 240 -- 10,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 7.00 -- 3.00 4.50 2.53 u -- -- u u -- u u u u u -- QRH2 7-40 2, 3 -- 100250 100250 -- 240 240 -- 25,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 7.00 -- 3.00 4.50 2.53 u -- -- u u -- u u u u u -- HQR2 7-40 2, 3 -- 100250 100250 -- 240 240 -- 65,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 7.00 -- 3.00 4.50 2.53 u -- -- u u -- u u u u u -- HQR2H 7-40 2, 3 -- 100250 100250 -- 240 240 -- 100,000 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 7.00 -- 3.00 4.50 2.53 u u -- u u -- u u u u u -- MOLDED CASE 7 CIRCUIT BREAKERS BQ1B020 BQ1B020H HB1B020 For inches / millimeters conversion, see Application Data section. CQD breakers are rated 14,000 KAIC at 480/277V. Type CQD6--CSA only. 3-pole only. d Applicable for 15-30A breakers only. 7-8 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Reference Guide Thermal-Magnetic Trip Breakers Ratings Interrupt Rating Symmetrical RMS Amperes Page AC DC Dimensions in inches Overcurrent Devices Accessories and Modifications Individual Enclosures Poles 1-Pole Amperes, Continuous 2-Pole 3-Pole 1-Pole Volts (50/60 Hertz) 2-Pole 3-Pole 120V UL 240V 480V 600/347V 220/ 240V 1-Pole Icu Ics 2,3- Icu Pole Ics IEC 947-2 50/ 60Hz 380/ 415V 1-Pole Icu Ics 2,3- Icu Pole Ics Volts -- 2-Pole 500V 1-Pole Icu Ics 2,3- Icu Pole Ics Interrupting Rating -- DC Amperes 1550A Height 55125A 60225A 1-Pole Width 2-Pole 3-Pole Depth Thermal and Fixed Magnetic Trip Molded Case Switch Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Fungus Proofing (ref. page 7-159) Type 1 -- Indoor Surface Type 1 -- Indoor, Flush Type 3R -- Outdoor-Rainproof Type 5, 12 --Lint, Fine Dust, Oils, Coolants General Purpose Breakers CQD 7-42 1, 2, 3 15100 15100 15100 277 480/277 480/277 65,000 65,000 14,000 10,000b 18,000d 9,000d 65,000d 32,500d -- -- 18,000d 9,000d -- -- -- -- 125/250 14,000 4.50 4.50 -- 1.00 2.00 3.00 2.87 u -- -- u u u -- u -- -- -- -- NGG 7-43 1, 2, 3 15125 15125 15-125 347 600/347 600/347 65,000 65,000 25,000 14,000 25,000 12,500 65,000 32,500 -- -- 25,000 12,500 -- -- -- -- 125/250 14,000 5.40 5.40 -- 1.00 2.00 3.00 2.90 u -- -- u u u -- u u u u -- HGG 7-43 1, 2, 3 15125 15125 15125 347 600/347 600/347 65,000 65,000 35,000 14,000 -- -- -- -- -- -- -- -- -- -- -- -- 125/250 14,000 5.40 5.40 -- 1.00 2.00 3.00 2.90 u -- -- u u u -- u u u u u Revised on 11/30/19 Selection/Application LGG 7-43 1, 2, 3 15125 15125 15125 347 600/347 600/347 65,000 65,000 65,000 14,000 -- -- -- -- -- -- -- -- -- -- -- -- 125/250 14,000 5.40 5.40 -- 1.00 2.00 3.00 2.90 u -- -- u u u -- u u u u u MOLDED CASE 7 CIRCUIT BREAKERS CQD120 LGG2B020L For inches / millimeters conversion, see Application Data section. CQD breakers are rated 14,000 KAIC at 480/277V. Type CQD6--CSA only. 3-pole only. d Applicable for 15-30A breakers only. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-9 Molded Case Circuit Breakers 3VA UL Breakers Revised on 01/31/21 Reference Guide MOLDED CASE 7 CIRCUIT BREAKERS Type 3VA51 Page 7-50 Number of Poles 1 3VA5 molded case circuit breakers Size 125 A Rated current In A 15 ... 125 Frequency Hz 0 ... 400 3VA51 7-50, 7-51, 7-52 2, 3, 4 125 A 15 ... 125 0 ... 400 3VA52 7-58, 7-59, 7-60 2 in 3-pole, 3, 4 250 A 100 ... 250 0 ... 400 3VA53 7-66, 7-67 2 in 3-pole, 3, 4 400 A 200 ... 400 0 ... 400 3VA54 7-71 2 in 3-pole, 3, 4 600 A 400 ... 600 0 ... 400 3VA55 7-75 3, 4 800 A 600 ... 800 0 ... 400 Electrical characteristics according to UL489 Rated operational voltage 50/60 Hz AC V 347 600 600 600 600 600 Electrical characteristics according to IEC 60947-2 Rated operational voltage Ue 50/60 Hz AC V 415 690 690 690 690 690 Rated insulation voltage Ui V 500 800 800 800 800 800 Rated impulse withstand voltage Uimp kV 8 8 8 8 8 8 Short-circuit breaking capacity according to UL 489 UL Breaker Type 120 V AC / 50/60 Hz kA 240 V AC / 50/60 Hz kA 277 V AC / 50/60 Hz kA 347 V AC / 50/60 Hz kA 480 Y/277 V AC / 50/60 Hz kA 480 V AC / 50/60 Hz kA 600 Y/347 V AC / 50/60 Hz kA 600 V AC / 50/60 Hz kA 125 V DC kA 250 V DC kA 500 V DC kA 600 V DC (3-pole only) kA 750 V DC (4-pole only) kA 1000 V DC (4-pole only) kA S M H SMH SEAS MEAS HEAS SEAS MEAS HEAS 65 85 150 -- -- -- -- -- -- 65 85 100 25 35 50 -- -- -- 14 18 18 -- -- -- -- -- -- 25 35 65 -- -- -- 25 35 65 -- -- -- 14 18 25 -- -- -- ------ 14 25 30 -- -- -- -- -- -- 50 85 100 -- -- -- 50 85 100 -- -- -- ------ -- -- -- ------ -- -- -- ------ MH MFAS HFAS -- -- 85 100 -- -- -- -- 35 65 35 65 18 25 18 25 -- -- 50 85 50 85 50 85 50 85 50 85 C CFAS -- 200 -- -- 100 100 35 35 -- 100 100 100 100 100 MH MJAS HJAS -- -- 85 100 -- -- -- -- 35 65 35 65 18 25 18 25 -- -- 50 85 50 85 50 85 50 85 6 6 C CJAS -- 200 -- -- 100 100 35 35 -- 100 100 100 100 10 MH C MH C MLAS HLAS CLAS MMAS HMAS CMAS ---- -- ------ 85 100 200 85 100 200 ---- -- ------ ---- -- ------ 35 65 100 35 65 100 35 65 100 35 65 100 18 25 35 18 25 50 18 25 35 18 25 50 ---- -- ------ 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100 6 6 10 18 25 50 Short-circuit breaking capacity according to IEC 60947-2 S M H SMH MH C MH C MH C MH C Rated ultimate short-circuit breaking capacity Icu Rated service short-circuit breaking capacity Ics rms value, according to IEC 60947-2 240 V AC / 50/60 Hz kA 25/25 36/36 55/55 55/55 85/85 150/150 85/85 100/100 200/200 85/85 100/100 200/200 85/85 100/100 200/200 85 100 200 415 V AC / 50/60 Hz kA 5/5 5/5 5/5 36/36 55/55 70/70 55/55 70/70 110/110 55/55 70/70 110/110 55/55 70/70 110/110 55 70 110 690 V AC / 50/60 Hz kA -- -- -- 5/5 7/5 10/5 7/7 10/10 10/10 7/7 10/10 10/10 7/7 10/10 10/10 25 35 35 125 V DC kA 14 25 30 -- -- -- -- -- -- ---- -- ---- -- ------ 250 V DC kA -- -- -- 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100 500 V DC kA -- -- -- 50 85 100 50 85 100 50 85 100 50 85 100 50 85 100 750 V DC (3-pole only) kA -- -- -- -- -- -- 50 85 100 50 85 100 50 85 100 50 85 100 -- Not available Applicable Standards: n UL489 - Molded Case Circuit Breakers n UL486A - Wire connectors and solderless lugs for use with copper n UL486B- Wire connectors and solderless lugs for use with aluminum wire n CSA-22.2 No. 5-13 - Molded Case Circuit Breakers, Molded case switches and circuit breaker enclosures n EN 60947-1 AMD 2 - Molded case circuit breakers n EN 60947-2 AMD 2 2013 n EN 50581 2012 - RoHS compliant n All 3VA breakers are HACR rated per UL 7-10 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers 3VA UL Breakers Revised on 02/28/22 Reference Guide MOLDED CASE 7 CIRCUIT BREAKERS 3VA61 7-54, 7-55 3, 4 150 A 15 ... 125 0 ... 400 600 3VA62 7-62, 7-63 3, 4 250 A 15 ... 125 0 ... 400 600 3VA63 7-68, 7-69 3, 4 400 A 100 ... 250 0 ... 400 600 3VA64 7-72, 7-73 3, 4 600 A 200 ... 400 0 ... 400 600 3VA65 7-76, 7-77 3, 4 800A 600-800 50-60 600 3VA66 7-79, 7-80 3, 4 1000A 1000 50-60 600 690 690 690 690 690 690 800 800 800 800 800 800 8 8 8 8 8 8 M H C L E M H C L E MH C L E MH C L E M H C M H C MDAE HDAE CDAE LDAE EDAE MFAE HFAE CFAE LFAE EFAE MJAE HJAE CJAE LJAE EJAE MLAE HLAE CLAE LLAE ELAE MMAE HMAE CMAE MMNAE HMNAE CMNAE -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- 100 100 200 200 -- 100 100 200 200 -- 100 100 200 200 -- 100 100 200 200 -- 100 150 200 100 150 200 -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- 35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 35 65 100 35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 150 200 35 65 100 35 65 100 18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 25 35 50 25 35 50 18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 18 22 35 50 100 25 35 50 25 35 50 -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- M H C L E M H C L E MH C L E MH C L E M H C M H C 85/85 110/110 150/150 200/200 -- 85/85 110/110 150/150 200/200 -- 85/85 110/110 150/150 200/200 -- 85/85 110/110 150/150 200/200 -- 85/85 55/55 85/85 110/110 150/150 150/150 55/55 85/85 110/110 150/150 150/150 55/55 85/85 110/110 150/150 150/110 55/55 85/85 110/110 150/150 150/110 55/55 2.5/2.5 2.5/2.5 2.5/2.5 2.5/2.5 3/3 3/3 3/3 3/3 3/3 3/3 5/5 5/5 5/5 5/5 6/6 6/6 6/6 6/6 6/6 6/6 25/19 -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- -- -- -- -- -- ---- -- ---- ---------- -- -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- -- -- -- -- -- -- -- -- -- -- ---- -- ---- -------- -- -- 110/110 200/150 85/85 85/85 110/85 55/55 35/19 35/19 25/19 -- -- -- -- -- -- -- -- -- -- -- -- 110/110 200/150 85/85 110/85 35/19 35/19 -- -- -- -- -- -- -- -- UL Type Structure Position 1 KAIC @ 480V S = 25=low M = 35=med low H = 65=med C = 100=med high L = 150=high E = 200=extra high Position 2 Frame E = 125A max D = 150A max F = 250A max J = 400A max L = 600A max M = 800A max MN = 1000A max Position 3 Family A = 3VA Position 4 Trip System / Special Application S = Standard TMTU or MCS (Molded Case Switch) E = High End ETU B = Panelboard TMTU (Bolt-on) M = TMTU 50°C/NAVAL (UL 489 SB) P = TMTU MCP (Motor Circuit Protector) R = ETU MCP (Motor Circuit Protector) Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-11 Molded Case Circuit Breakers Revised on 10/31/18 Reference Guide Selection/Application Thermal-Magnetic Trip Breakers General Purpose Breakers ED2 Page 7-114 Poles 1, 2, 3 Amperes, Continuous 15100 1-Pole 120 Volts 50/60HZ 2-Pole 240 3-Pole 240 120V 10,000 240V 10,000 Ratings Interrupt Rating Symmetrical RMS Amperes 277V -- UL AC 347V -- 480V -- 600V -- 220/240V Icu -- IEC Ics -- 947-2 50/ 380/415V Icu Ics -- -- 60HZ 500V Icu -- Ics -- 2-Pole, 250V DC Interrupting Ratings 5,000 DC 3-Pole, 500V DC Interrupting Ratingsc -- Height 6.34 1-Pole 1.00 Dimensions in inches Width 2-Pole 2.00 3-Pole 3.00 4-Pole -- Depth 4.00 Thermal and Fixed Magnetic Trip u Thermal and Adjustable Magnetic Trip -- Overcurrent Devices Adjustable Magnetic Trip only -- Motor Circuit Protector Molded Case Switch u Undervoltage Trip u Shunt Trip u Auxiliary Switch u Accessories Alarm Switch u and Mechanical Interlock -- Modifications Rear Connection Studs u Electric Motor Operator u Plug-In Mounting Assembly (3 Pole Only) u Fungus Proofing (ref. page 7-159) u Type 1 -- Indoor Surface u Type 1 -- Indoor, Flush u Individual Enclosures Type 3R -- Outdoor-Rainproof u Type 7 -- Flammable Gas Atmosphere u Type 9 -- Combustion Dusttight u Type 5, 12 --Lint, Fine Dust, Oils, Coolants u Type 12K -- Semi-Dusttight u ED4 7-114 1, 2, 3 15125 277 480 480 -- 65,000 22,000a -- 18,000 -- -- -- -- -- 30,000 -- 6.34 1.00 2.00 3.00 -- 4.00 u -- -- ED6 7-114 1d, 2, 3 15125 347 600 600 -- 65,000 -- 30,000 25,000 18,000 65,000h 17,000h 35,000h 9,000h 18,000h 5,000h 30,000 18,000 6.34 1.00 2.00 3.00 -- 4.00 u -- u HED4 HHED6 7-115 7-115 1, 2, 3 3 15125 1550 277 -- 480 600 480 600 100,000 -- 100,000e 100,000 65,000b -- -- -- 142,000 65,000 -- 18,000 -- -- -- -- -- -- -- -- -- -- -- -- 30,000 -- -- -- 6.34 6.58 1.00 -- 2.00 2.00 3.00 3.00 -- -- 4.00 4.00 u u -- -- -- -- u u -- -- u u u u u u u u u u u u u u u u -- -- -- -- u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u CED6 7-115 2, 3 15125 -- 600 600 -- 200,000 -- -- 200,000 100,000 -- -- -- -- -- -- 30,000 50,000 9.26 -- 2.00 3.00 -- 4.00 u -- u u u u u u -- u u u u u u u -- -- u u FD6A, FXD6A 7-117 2, 3 70250 -- 600 600 -- 65,000 -- -- 35,000 22,000 65,000 33,000 35,000 18,000 -- -- 30,000 18,000 9.50 -- 4.50 4.50 -- 4.00 -- u u u u u u u u u u u u u u -- u u u u u HFD6, HFXD6 7-118 2, 3 70-250 -- 600 600 -- 100,000 -- -- 65,000 25,000 100,000 50,000 65,000 33,000 -- -- 30,000 25,000 9.50 -- 4.50 4.50 -- 4.00 -- u -- -- -- u u u u u u u u u u u u u u u u HHFD6, HHFXD6 CFD6 7-118 7-118 2, 3 3 70-250 70250 -- -- 600 600 600 600 -- -- 200,000 200,000 -- -- -- -- 100,000 200,000 25,000 100,000 -- -- -- -- -- -- -- -- -- -- -- -- -- 50,000 -- 50,000 14.12 14.12 -- -- 4.50 4.50 4.50 4.50 -- -- 4.00 4.00 -- -- u u -- u -- u -- u u u u u u u u u u u u u u u u u u u u u -- u u u u -- u -- u u u u MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. a 1-pole only. b 35-100A: 25,000 AIR at 277V AC/15-30A: 65,000 AIR at 277V AC. c For DC UPS system application. d Single pole ED6 (1530A) 30kA, (35100A) 18 kA. CSA Only. e Single pole HED4, 15-30A: 65,000 AIR at 240V AC; single pole HED4, 35-100A: 25,000 AIR at 240V AC. f HGG and LGG breakers are rated at 600/347V. g ED6, 2-pole available 20-30 amps only. h Rating applicable only to 3-pole breakers 7-12 Siemens Industry, Inc. SPEEDFAXTM Product Catalog ED62B020 HED41B040 HHED63B020 Molded Case Circuit Breakers Revised on 10/31/18 Reference Guide Selection/Application Thermal-Magnetic Trip Breakers Ratings Interrupt Rating Symmetrical RMS Amperes Page AC DC Dimensions in inches Overcurrent Devices Accessories & Modifications Individual Enclosures Poles Amperes, Continuous Volts 50/60HZ 2-Pole 3-Pole 240V UL 480V 600V 220/ Icu 240V Ics IEC 947-2 380/ Icu 50/60HZa 415V Ics Icu 500V Ics 2-Pole 250V DC Interrupting Ratings 3-Pole, 500V DC Interrupting Ratingsb Height Width 2, 3-Pole Depth Thermal and Fixed Magnetic Trip Thermal and Adjustable Magnetic Trip Adjustable Magnetic Trip Only Motor Circuit Protector Molded Case Switch Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Rear Connection Studs Electric Motor Operator Plug-In Mounting Assembly Fungus Proofing (ref. page 7-159) Type 1 -- Indoor Surface Type 1 -- Indoor, Flush Type 3R -- Outdoor-Rainproof Type 7 -- Flammable Gas Atmosphere Type 9 -- Combustion Dusttight Type 5, 12 --Lint, Fine Dust, Oils, Coolants Type 12K -- Semi-Dusttight General Purpose Breakers JD6-A, HJD6-A, HHJD6-A, JXD2-A JXD6-A HJXD6-A HHJXD6-A CJD6-A 7-120 7-120 7-121 7-121 7-121 2, 3 2, 3 2, 3 2, 3 3 200-400 200-400 200-400 200-400 200-400 240 600 600 600 600 65,000 -- -- -- -- -- -- -- -- 30,000 -- 11.00 7.50 4.00 -- u 65,000 35,000 25,000 65,000 33,000 40,000 20,000 -- -- 30,000 25,000 11.00 7.50 4.00 -- u 100,000 65,000 35,000 100,000 50,000 65,000 33,000 -- -- 30,000 35,000 11.00 7.50 4.00 -- u 200,000 100,000 50,000 -- -- -- -- -- -- -- -- 11.00 7.50 4.00 -- u 200,000 150,000 100,000 -- -- -- -- -- -- -- 50,000 17.86 7.50 4.00 -- u -- u -- -- u u u u -- u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u -- u u u u u u u u u -- -- -- -- -- u u u u u u u u u -- u u u u -- u u u u u u u u u u LD6, LXD6 7-124 2, 3 250-600 600 65,000 35,000 25,000 65,000 33,000 40,000 20,000 -- -- 30,000 35,000 11.00 7.50 4.00 -- u u u u u u u u u u u u u -- u u u u u HLD6, HLXD6 7-125 2, 3 250-600 600 100,000 65,000 35,000 100,000 50,000 65,000 33,000 -- -- 30,000 -- 11.00 7.50 4.00 -- u -- u u u u u u u u u u u -- u u u u u HHLD6, HHLXD6 7-125 2, 3 250-600 600 200,000 100,000 50, 000 -- -- -- -- -- -- -- -- 11.00 7.50 4.00 -- u -- -- u u u u u u u u u u -- u u u u u CLD6-A 7-125 3 450-600 600 200,000 150,000 100,000 -- -- -- -- -- -- -- 50, 000 17.86 7.50 4.00 -- u u u u u u u u u u u u u -- u -- -- u u MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. a Only applicable to non-interchangeable trip unit types: JXD6-A, HJXD6-A, LXD6 and HLXD6 b For DC UPS application. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-13 Molded Case Circuit Breakers Revised on 10/31/18 Reference Guide Selection/Application Thermal-Magnetic Trip Breakers General Purpose Breakers LMD6, HLMD6, MD6, LMXD6 HLMXD6 MXD6 Page 7-128 7-129 7-131 Poles 2, 3 2, 3 2, 3 Amperes, Continuous 500- 500- 500- 800 800 800 Volts 50/60 HZ 2-Pole 3-Pole 600 600 600 240V 65,000 100,000 65,000 Ratings Interrupt Rating Symmetrical RMS Amperes UL 480V 50,000 65,000 50,000 AC 600V 25,000 50,000 25,000 220/ Icu -- -- 65,000 240V Ics -- -- 33,000 IEC 947-2 380/ Icu -- -- 40,000 50/60HZc 415V Ics -- -- 20,000 Icu -- -- -- 500V Ics -- -- -- 2-Pole 250V DC Interrupting Ratings 30,000 DC 3-Pole, 500V DC Interrupting Ratingsa 25,000 30,000 50,000 30,000 25,000 Dimensions in inches Circuit breakers require Connect-all mounting block. Dims shown are for circuit breaker only. Height Width Depth 16.00 7.50 4.59 16.00 7.50 4.59 16.00 9.00 6.19 Overcurrent Thermal and Adjustable Magnetic Trip u Devices Adjustable Magnetic Trip Only Motor Circuit Protector u u u -- u Molded Case Switch Accessories Undervoltage Trip and Shunt Trip Modifications Auxiliary Switch u -- u u u u u u u Alarm Switch u u u Mechanical Interlock u u u Rear Connections Studs u u u Electric Motor Operator u u u Plug-in Mounting Assembly u u u Fungus Proofing (ref. page 7-159) -- -- u Mounting Block (required) -- -- -- Individual Type 1 -- Indoor Surface Enclosures Type 1 -- Indoor, Flush u u u -- -- -- Type 3R -- Outdoor-Rainproof u u u Type 7 -- Flammable Gas Atmosphere -- -- -- Type 9 -- Combustion Dusttight -- -- -- Type 5, 12 --Lint, Fine Dust, Oils, Coolants -- -- -- Type 12K -- Semi-Dusttight u u u HMD6, HMXD6 7-132 2, 3 500800 CMD6 7-132 3 400800 ND6, NXD6 7-135 2, 3 8001200 HND6, HNXD6 7-136 2, 3 8001200 CND6 7-136 3 8001200 PD6,b PXD6b 7-139 3 12001600 HPD6,b HPXD6b 7-139 3 12001600 CPD6b 7-139 3 12001600 600 600 600 600 600 600 600 600 100,000 65,000 50,000 100,000 50,000 65,000 33,000 -- -- 30,000 50,000 16.00 9.00 6.19 200,000 65,000 100,000 100,0001 50,000 65,000 65,0001 25,000 50,000 -- 65,000 100,000 -- 33,0001 50,000 -- 40,0001 65,000 -- 20,00011 33,000 --1 -- -- -- --1 -- 30,0001 30,0001 30,000 50,000 25,00011 50,000 16.00 16.00 16.00 9.00 9.00 9.00 6.19 6.191 6.19 200,000 100,000 65,000 -- -- -- -- -- -- 30,000 50,000 16.00 9.00 6.19 65,000 50,000 25,000 -- -- -- -- -- -- 30,000 25,000 16.0 9.00 6.19 100,000 65,000 50,000 -- -- -- -- -- -- 30,000 50,000 16.00 9.00 6.19 200,000 100,000 65,000 -- -- -- -- -- -- 30,000 50,000 16.00 9.00 6.19 u u u u u u u u -- u -- -- -- -- -- -- u -- u u -- -- -- u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u -- -- -- u u u u u u u u u u u u u -- -- -- u u u u u u u u -- -- -- -- -- u u u u u u u u u u u -- -- -- -- -- -- -- -- u u u u u -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- u u u u u -- -- -- MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. a For DC UPS application. b Requires Connect-all mounting assembly. Dimensions shown are for circuit breaker only. c Only applicable to non-interchangeable trip unit types: NXD6, HNXD6, MXD6 and HMXD6 7-14 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Revised on 05/31/18 ReferenceGuide Selection Thermal-Magnetic Trip Breakers & Electronic Trip Breakers Page Ratings Dimensions in inches Overcurrent Devices Accessories & Modifications Individual Enclosures Poles Amperes, Continuous Volts 50/60 HZ 3-Pole 240V UL 480V 600V AC Interrupt Rating Symmetrical RMS Icu 220/240V Ics Amperes IEC60947-2 380/415V Icu 50/60HZ Ics Icu 500V Ics 2-Pole 250V DC Interrupting Ratings DC 3-Pole, 500V DC Interrupting Ratingsa Height Width 3-Pole Depth Solid State Trip Optional DAS / Maintenance Mode Thermal and Adjustable Magnetic Trip Adjustable Magnetic Trip Only Motor Circuit Protector Molded Case Switch Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Rear Connections Studs Electric Motor Operator Plug-In Mounting Assembly Fungus Proofing (ref. page 7-159) Mounting Block (required) Type 1 -- Indoor Surface Type 1 -- Indoor, Flush Type 3R -- Outdoor-Rainproof Type 7 -- Flammable Gas Atmosphere Type 9 -- Combustion Dusttight Type 5, 12 --Lint, Fine Dust, Oils, Coolants Type 12K -- Semi-Dusttight General Purpose Breakers RD6,a RXD6a HRD6,a HRXD6a 7-142 7-142 3 3 1600-2000 1600-2000 600 600 65,000 100,000 50,000 65,000 25,000 50,000 -- -- -- -- -- -- -- -- -- -- -- -- 30,000 30,000 25,000 50,000 16.00 16.00 9.00 9.00 6.19 6.19 -- -- -- -- u u -- -- u -- u u u u u u u u u u -- -- u u -- -- u u u u u u -- -- -- -- -- -- -- -- -- -- -- -- Solid State Trip Circuit Breakers SJD6 7-122 3 200-400 600 65,000 35,000 25,000 -- -- -- -- -- -- -- -- 11.00 7.50 4.00 u u -- -- SHJD6 7-122 3 200-400 600 100,000 65,000 35,000 -- -- -- -- -- -- -- -- 11.00 7.50 4.00 u u -- -- SCJD6 7-122 3 200-400 600 200,000 150,000 100,000 -- -- -- -- -- -- -- -- 17.86 7.50 4.00 u u -- -- -- -- -- u u u u u u u u u u u u u u u u u u u u u u u u u u u -- -- -- u u u -- -- -- u u -- u u -- u u -- u u u u u u SLD6 7-126 3 300-600 600 65,000 35,000 25,000 -- -- -- -- -- -- -- -- 11.0 7.50 4.00 u u -- -- -- u u u u u u u u u -- u -- u u u u u SHLD6 7-126 3 300-600 600 100,000 65,000 35,000 -- -- -- -- -- -- -- -- 11.00 7.50 4.00 u u -- -- SCLD6 7-126 3 300-600 600 200,000 150,000 100,000 -- -- -- -- -- -- -- -- 17.86 7.50 4.00 u u -- -- -- -- u u u u u u u u u u u u u u u u u u -- -- u u -- -- u -- u -- u -- u u u u MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. a Requires Connect-all mounting assembly. Dimensions shown are for circuit breaker only. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-15 Molded Case Circuit Breakers Revised on 05/31/18 ReferenceGuide Electronic Trip Breakers Solid State Trip Circuit Breakers SMD6 SHMD6 SCMD6 Page Poles Amperes, Continuous - Volts 50/60HZ 3-Pole 240V 7-133 3 600800 600 65,000 7-133 3 600800 600 100,000 7-133 3 600800 600 200,000 Ratings AC Interrupt Rating Symmetrical RMS Amperes Dimensions in inches Height Width Depth UL 480V 600V Icu 380/415V IEC60947-2 Ics 50/60HZ Icu 690V Ics 50,000 25,000 -- -- -- -- 16.00 9.00 6.19 65,000 50,000 -- -- -- -- 16.00 9.00 6.19 100,000 65,000 -- -- -- -- 16.00 9.00 6.19 Overcurrent Devices Solid State Trip Optional DAS / Maintenance Mode u u u u u u Accessories & Modifications Undervoltage Trip Shunt Trip Auxiliary Switch Alarm Switch Mechanical Interlock Rear Connection Studs Electric Motor Operator Plug-In Mounting Assembly u u u u u u u u u u u u u u u u u u u u u u u u Individual Enclosures Fungus Proofing (ref. page 7-159) Type 1 -- Indoor Surface Type 1 -- Indoor, Flush Type 3R -- Outdoor-Rainproof Type 7 -- Flammable Gas Atmosphere Type 9 -- Combustion Dusttight u u u u u u -- -- -- u u u -- -- -- -- -- -- Type 5, 12 --Lint, Fine Dust, Oils, Coolants u u u Type 12K -- Semi-Dusttight u u u SND6 7-137 3 8001200 600 65,000 50,000 25,000 -- -- -- -- 16.00 9.00 6.19 u u u u u u u u u u u u -- u -- -- u u SHND6 7-137 3 8001200 600 100,000 65,000 50,000 -- -- -- -- 16.00 9.00 6.19 u u u u u u u u u u u u -- u -- -- u u SCND6 7-137 3 8001200 600 200,000 100,000 65,000 -- -- -- -- 16.00 9.00 6.19 u u u u u u u u u u u u -- u -- -- u u Selection SPD6 a 7-140 3 12001600 600 65,000 50,000 25,000 -- -- -- -- 16.00 9.00 6.19 u u u u u u u -- u -- u u -- -- -- -- -- -- SHPD6 a 7-140 3 12001600 600 100,000 65,000 50,000 -- -- -- -- 16.00 9.00 6.19 u u u u u u u -- u -- u u -- -- -- -- -- -- MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. a Requires connect-all mounting block assembly. Dimensions shown are for circuit breaker. 7-16 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Reference Guide Revised on 10/31/18 Selection/Application Page Breaker Frame Family Continuous Amps Poles Max. Volts AC Breaker Type Interrupting Class Ratings Interrupting Rating RMS Symmetrical Amperes AC 50/60Hz UL lCU/lCS Dimensions in Inches DC Interrupting Ratings (UL) b 1-Pole 2-Pole 3-Pole 4-Pole 240Vac 480Vac 600Vac 220/240Vac 380/415Vac 690Vac 250Vdc (2-Pole) 500Vdc (3-Pole) 600Vdc (3-Pole) Thermal-Magnetic Electronic Trip Unit Information Electronic with LCD Interchangeable Trip Unit Reverse Feed (w/Non-Interchangeable Trip) Communications Capability Specific Application Breakers Molded Case Switch Motor Circuit Protector 100% Rated 50°C Calibrated Auxiliary Switch Alarm Switch Shunt Trip Undervoltage Release Accessories & Mechanical Interlocks Modifications Electric Motor or Stored Energy Operator Rear Connecting Studs Plug-In Mounting Assy. w/Trip Interlock Draw-Out Assembly Handle Mechanism Options NEMA 1 Indoor, Surface Mount NEMA 1 Indoor, Flush Mount Enclosures NEMA 3R Outdoor, Rain Proof NEMA 4, 4X Stainless Steel NEMA 7, 9 Hazardous Locations NEMA 12 Dust Terminal Shields Distribution Lugs Ground Sensor (Neutral Transformer) 7-177 7-181 DG 30150A 2, 3 600Y/347V NDGA HDGA LDGA NFGA FG 40250A 2, 3 600Y/347V HFGA LFGA N H L N H L 65 100 200 65 100 200 35 65 100 35 65 100 18 65/65 18 18 18 100/75 200/150 65/65 18 18 100/75 200/150 40/40 70/70 100/75 40/40 70/70 100/75 12/6 12/6 12/6 12/6 12/6 12/6 30 30 30 30 30 30 18 18 18 18 18 30 -- -- -- -- 42 -- -- 6.9H x 4.1W x 3.4D 6.9H x 4.1W x 3.4D -- u u u u u u -- -- u u u u u u u u u 7-185 JG 70400A 2, 3 600V NJGA HJGA LJGA N H L 65 100 200 35 65 100 25 25 25 65/65 100/75 200/150 45/45 70/70 100/75 12/6 15/8 15/8 30 30 30 25 35 35 -- 65 -- -- 11H x 5.5W x 4.2D 11H x 5.5W x 4.2D -- u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u MOLDED CASE 7 CIRCUIT BREAKERS a 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. b DC Interrupting Ratings are not applicable to electronic circuit breakers. Communications available via a COMPRO or COMMOD modules using Profibus or Modbus protocols. Consult Siemens for availability. "Non-metallic" NEMA 4X enclosure for NGG breakers. Special version, see page 7-206. GG are not VL family breakers and do not share common VL accessories. 304 and 316 Stainless Steel Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-17 Molded Case Circuit Breakers Reference Guide Selection/Application Page Breaker Frame Family Breaker Type Continuous Amps Poles Max. Volts AC Ratings Interrupting Class Interrupting UL Rating RMS Symmetrical Amperes AC 50/60Hz lCU/ lCS DC Interrupting Ratings (UL)c 240Vac 480Vac 600Vac 220/240Vac 380/415Vac 690Vac 250Vdc (2-Pole) 500Vdc (3-Pole) 600Vdc (3-Pole) Dimensions in Inches 2-Pole 3-Pole Thermal-Magnetic Electronic Trip Unit Information Electronic with LCD Interchangeable Trip Unit Reverse Feed (w/Non-Interchangeable Trip) Communications Capabilitya Specific Application Breakers Molded Case Switch Motor Circuit Protector 100% Rated Auxiliary Switch Alarm Switch Shunt Trip Accessories and Modifications Undervoltage Release Mechanical Interlocks Electric Motor or Stored Energy Operator Rear Connecting Studs Plug-In Mounting Assy. w/Trip Interlock Draw-Out Assembly Handle Mechanism Options Terminal Shields Distribution Lugs Ground Sensor (Neutral Transformer) 7-189 LG 150600A 2, 3 600V NLGB HLGB LLGB N H L 65 100 200 35 65 100 18 18 18 65/65 100/75 200/150 45/45 70/70 100/75 12/6 15/8 15/8 30 30 30 25 35 35 -- 65 -- 11H x 5.5W x 4.2D 11H x 5.5W x 4.2D u u u u u u u u u u u u u u u u u u u u u 7-193 MG 200800A 2, 3 600V NMG HMG LMG 7-197 NG 3001200A 2, 3 600V NNG HNG LNG 7-201 PG 4001600A 3 600V NPG HPG LPG N 65 35 25 65/35 50/50 20/10 22 35 H L N 100 200 65 65 100 35 35 65 25 100/50 200/150 65/65 70/70 100/75 50/25 30/15 35/17 20/10 25 42 22 50 65 35 H 100 65 35 100/75 70/35 30/15 25 50 L 200 100 65 200/100 100/50 35/17 42 65 N 65 35 25 65/35 50/25 20/10 22 35 H 100 65 35 100/50 70/35 30/15 25 50 L 200 100 65 200/100 100/50 35/15 42 65 -- 65 -- -- 65 -- -- 65 -- 16H x 7.5W x 4.7D 16H x 7.5W x 4.7D u u u u u u u u u u u u u u u u 16H x 9W x 6.2D -- 16H x 9W x 6.2D u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u u a Communications available via COMPRO or COMMOD modules using Profibus or Modbus protocol. b 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. c DC Interrupting Ratings are not applicable to electronic circuit breakers. LG frame maximum 500A. Special version, see page 7-206. Special 600Vac 25kA version available, see page 7-190. MOLDED CASE 7 CIRCUIT BREAKERS 7-18 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Circuit Breakers Revised on 03/31/21 Arc-Fault and Ground-Fault Breakers Arc-Fault Circuit Interrupters (AFCI) AFCI's are designed to detect arcing faults (an unintentional arcing condition in a circuit) and mitigate the effects by functioning to de-energize the circuit when an arc-fault is detected. Combination Type AFCI Detects all three possible types of arc faults: line-to-ground, line-to-neutral and series arcs. Breaker Type Amp 10,000 A IR Rating Catalog No. 22,000 A IR Catalog No. 65,000 A IR Catalog No. QAF2/QAFH2/HQAF2 1-Pole 120V AC QAF/QAFH 2-Pole 120/240V AC QTA NEW Tandem 120V AC QAF2N Plug-on Neutral / 1-Pole 120V AC QAFN Plug-on Neutral / 2-Pole 120/240V AC QTAN NEW Plug-on Neutral / Tandem 120V AC 15 20 15 20 15/15 20/20 15 20 15 20 15/15 20/20 QA115AFC QA120AFC Q215AFC Q220AFC Q1515AFC Q2020AFC QA115AFCN QA120AFCN Q215AFCN Q220AFCN Q1515AFCN Q2020AFCN QA115AFCH QA120AFCH Q215AFCHn Q220AFCHn -- -- -- -- -- -- -- -- QA115AFCHH QA120AFCHHn -- -- -- -- -- -- -- -- -- -- Dual Function (AFCI/GFCI) The Dual Function Circuit Breaker combines Combination Type AFCI and 5mA Class A GFCI protection in one device. QFGA2/QFGAH2/HQFGA2 1-Pole 120V AC QFGA2N Plug-on Neutral / 1-Pole 120V AC 15 Q115DF 20 Q120DF 15 Q115DFN 20 Q120DFN Q115DFH Q120DFH -- -- Q115DFHHn Q120DFHHn -- -- Ground-Fault Circuit Interrupters (GFCI) Class A (5mA) Ground Fault Protection Intended for personnel protection. Breaker Type QPF2 / QPHF2 / HQPF2 1-Pole 120V AC QPF/QPHF 2-Pole 120/240V AC QPF2N Plug-on Neutral / 1-Pole 120V AC Amp 10,000 A IR Rating Catalog No. 15 QF115A 20 QF120A 30 QF130A 15 QF215A 20 QF220A 25 QF225A 30 QF230A 35 QF235A 40 QF240A 45 QF245A 50 QF250A 60 QF260A 15 QF115AN 20 QF120AN 30 QF130AN 22,000 A IR Catalog No. QF115AHn QF120AH QF130AHn QF215AH QF220AHn -- QF230AHn -- QF240AHn -- QF250AHn QF260AHn -- -- -- 65,000 A IR Catalog No. QF115AHH QF120AHHn QF130AHHn -- -- -- -- -- -- -- -- -- -- -- -- Ground-Fault Equipment Protection (30mA) QE2/QEH2 1-Pole 120V AC 15 QE115 20 QE120 30 QE130 15 QE215 20 QE220 QE/QEH 2-Pole 120/240V AC 30 QE230 40 QE240 50 QE250 60 QE260 QE115Hn QE120Hn QE130Hn QE215Hn QE220Hn QE230Hn QE240Hn QE250Hn QE260Hn Accessories Description Catalog Number Padlocking Device 1-Pole Padlocking Device 2-Pole ECPLD1 ECPLD2 n Built to order. Allow 8 -10 weeks for delivery. Handle Block ECBX231M Selection/Wiring Diagrams 1-Pole Combination Type AFCI 2-Pole Combination Type AFCI 1-Pole Dual Function AFCI/GFC 1-pole Tandem Type AFCI 1-Pole AFCI Plug-on Neutral 1-Pole Dual Function Plug-on Neutral 1-Pole GFCI 2-Pole GFCI 1-Pole Equipment Protection 2-Pole Equipment Protection MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-19 Circuit Breakers Type QP with INSTA-WIRE Continuous Current Rating @ 40° C Type QP 10,000A IR Catalog Number Type QPH 22,000A IR Catalog Number 1-Pole Plug-In (120/240V AC)e 10 Q110 15 Q115c 20 Q120c 25 Q125 30 Q130 35 Q135n 40 Q140 45 Q145n 50 Q150 60 Q160 70 Q170 -- Q115Hc Q120Hc Q125Hn Q130H Q135Hn Q140H Q145Hn Q150H Q160Hn Q170Hn 2-Pole Plug-In (Common-Trip 120/240V AC) 10 Q210 -- 15 Q215 Q215H 20 Q220 Q220H 25 Q225 Q225Hn 30 Q230 Q230H 35 Q235 Q235Hn 40 Q240 Q240H 45 Q245 Q245Hn 50 Q250 Q250H 60 Q260 Q260H 70 Q270 Q270H 80 Q280 Q280Hn 90 Q290 Q290H 100 Q2100 Q2100H 110 Q2110 Q2110H 125 Q2125 Q2125H 2-Pole Plug-In (Common-Trip 240V AC) 15 Q215R -- 20 Q220R -- 30 Q230R -- 40 Q240R -- 50 Q250R -- 3-Pole Plug-In (Common-Trip 240V AC) 15 Q315 Q315H 20 Q320 Q320H 25 Q325 Q325Hn 30 Q330 Q330H 35 Q335 Q335Hn 40 Q340 Q340H 45 Q345 Q345Hn 50 Q350 Q350H 60 Q360 Q360H 70 Q370 Q370H 80 Q380 Q380H 90 Q390 Q390H 100 Q3100 Q3100H Type HQP 65,000A IR Catalog Number -- Q115HHnc Q120HHnc Q125HHn Q130HHn Q135HHn Q140HHn Q145HHn Q150HHn Q160HHn Q170HHn -- Q215HH Q220HH Q225HHn Q230HH Q235HHn Q240HHn Q245HHn Q250HH Q260HH Q270HH Q280HHn Q290HHn Q2100HH Q2110HHn Q2125HH -- -- -- -- -- Q315HHn Q320HH Q325HHn Q330HH Q335HHn Q340HH Q345HHn Q350HH Q360HH Q370HHn Q380HHn Q390HHn Q3100HH Revised on 10/31/18 Selection Q120 Q220 Q320 MOLDED CASE 7 CIRCUIT BREAKERS QP / QPH / HQP Internal Accessories Control Voltage AC 120V Shunt Trip 24V Shunt Trip 120V Auxiliary Switch Catalog Number add suffix ...00S01n add suffix ...00S07n add suffix ...01nb Field/Factory Installed Factory Factory Factory Modifications Description 400 Hz Calibration Marine 50°C Ambient Calibration Fungus Proofing Catalog Number add suffix ...Yh add suffix ...M add suffix ...F For external accessories, please refer to page 7-161 n Built to order. Allow 2-3 weeks for delivery. a UL Listed for use with 60/75° wire through 40 amps, UL listed for use with 75° wire only for 50 amps and above, HACR rated. b 1A and 1B contacts. c UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting. d UL Listed for use on 3-phase grounded "B" systems -- 10,000 for this application. e Shipped 12 per sleeve. f Shipped 6 per sleeve. g Shipped 4 per sleeve. h UL Listed 5 KA IR. i Type QP1, UL listed for 16 AWG conductors and multiple wires. 7-20 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category RESI Circuit Breakers Duplex, Triplex and Quadplex Plug-In Breakers Duplex Circuit Breakers Breaker Type QT 1-Pole 10K AIC 120V AC Ampere Rating Catalog Number 1515 Q1515 1520 Q1520 2020 Q2020 2030 Q2030 3015n Q3015 3020 Q3020 3030 Q3030 SHIPPING: 12 per carton, (Wt. 4.8 lbs.) Triplex Circuit Breakers Ampere Rating Breaker Type QT 2-Pole 10K AIC 120/240V AC Inner Poles Common Trip Single Pole Common-Trip 2-Pole 15 15 15 20 15 25 15 30 15 35 15 40 15 45 15 50 20 20 20 25 20 30 20 35 20 40 20 45 20 50 30 30 SHIPPING: 6 per carton, (Wt. 4.9 lbs.) Quadplex Circuit Breakers Ampere Rating Breaker Type QT 2-Pole 10K AIC 120/240V AC Inner and Outter 2 Poles Common Trip Common-Trip 2-Pole Outside Common-Trip 2-Pole Inside 15 15 15 30 20 20 20 50 30 20 30 25 30 30 30 50 40 20 40 30 40 40 SHIPPING: 6 per carton, (Wt. 4.8 lbs.) Catalog Number Q1515NCa Q1520NCa Q2020NCa -- -- -- Q3030NCa Catalog Number Q21515CT Q21520CT Q21525CTn Q21530CT Q21535CTn Q21540CT Q21545CTn Q21550CT Q22020CT Q22025CTn Q22030CT Q22035CTn Q22040CT Q22045CTn Q22050CT Q23030CT Catalog Number Q21515CT2 Q21530CT2 Q22020CT2 Q22050CT2 Q23020CT2 Q23025CT2 Q23030CT2 Q23050CT2 Q24020CT2 Q24030CT2 Q24040CT2 Selection QT Duplex These space saver duplex breakers combine two independent 1/2" breaker poles in a common unit. This unit plugs into one load center stab and requires one panel space. HACR rated. QT Triplex These space saver triplex breakers provide a 2-pole common trip breaker for 120/240V AC circuits and two single poles for 120V AC circuits. Triplex require two panel spaces. HACR rated. QT Quadplex These space saver quadplex breakers provide two sets of common trip, two-pole breakers for 120/240V AC circuits, and require two panel spaces. HACR rated. MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. Product Category RESI For external accessories, please refer to page 7-161 n Built to order. Allow 23 weeks for delivery. a Non-CTL. For replacement use only in panels manufactured before 1968 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-21 Circuit Breakers Special Application Breakers HID Lighting For high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker. Breaker Type QP 1-Pole 120VAC QP 2-Pole 120/240VAC Wiring Diagram Figure 1 Figure 2 Complete Breaker UL Unenclosed Ampere Rating Catalog Number 15 Q115HID an 20 Q120HID a 30 Q130HID 15 Q215HID 20 Q220HID n 30 Q230HIDn Molded Case Switch For applications that do not require overcurrent protection. QP 1-Pole 120V AC Figure 1 100 QP 30 2-Pole 120/240V AC Figure 2 50 60 125 Q1100S Q230S Q250S Q260S Q2125S No-Noise For applications that require a reduction in the 60-cycle hum of a standard breaker. QP 2-Pole Figure 2 50 60 120/240V AC Q250NNn Q260NN Switching Neutrals Used where all conductors are required to be disconnected. Neutral pole of the circuit breaker does not connect to load center bus. One side is wired to neutral and the other side to the device. QG 2-Wire Common Trip Figure 3 15 20 120V AC QG 3-Wire Figure 4 20 Common Trip 120/240V AC QG215 QG220 QG320 Switching Neutral Figure 1 Figure 2 Figure 3 Figure 4 Wiring Diagrams Selection MOLDED CASE 7 CIRCUIT BREAKERS n Built to order. Allow 23 weeks for delivery. Note: All circuit breakers on this page are 10K AIC 7-22 Siemens Industry, Inc. SPEEDFAXTM Product Catalog a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. Product Category RESI Circuit Breakers 3/4 Inch Plug-In Breakers Features b 3/4" format b HACR Rated b UL Classified for use in certain Square D load centers Type QD Circuit Breakers The Type QD circuit breaker line is available in 1-pole and 2-pole common trip versions listed on this page. The circuit breakers are UL Classified and ULListed. All QD breakers are supplied with load side connectors suitable for 60/75°C wire and are calibrated for 40°C maximum ambient applications. UL Classified Siemens Type QD circuit breakers are UL Classified for use in specific Square D load centers in place of Square D Type QO® circuit breakers. A Panelboard Compatibility List packaged with each QD breaker shows which type QD circuit breakers are acceptable for use in Square D load centers. The interrupting rating on these circuit breakers is 10,000A IR maximum and they are not series rated with Square D circuit breakers or equipment. This UL Classification allows a Siemens Type QD circuit breaker to be used in place of a Square D Type QO circuit breaker in those load centers that are specifically shown on the Panelboard Compatibility list. For additional information, contact your local Siemens sales engineer. Selection D120 D220 Continuous Current Rating @ 40°C 15 20 30 40 50 60 1-Pole 120V Catalog Number D115 a D120 a D130 D140 D150 D160 2-Pole 120/240V Common Trip Catalog Number D215 D220 D230 D240 D250 D260 Shipping Weights Number of Poles 1 2 Number Per Carton 16 8 Shipping Weight (lbs.) 3.8 4.2 Panelboard Compatibility List Listed Panelboards--Square D--Catalog Numbers QO2L30F/S QO2-4L70F/S QO2-4L70TS QO2-4L70RB QO6-12L100F/S QO6-12L100DF/S QO6-12L100TF/S QO6-12L100DTF/S QO6-12L100RB QO8-16L100F/S QO8-16L100DF/S QO8-16L100TF/S QO8-16L100DTF/S QO8-16L100RB QO112M100/RB QO116M100/RB QO120M100/RB QO124M100 QO12L100DF/S QO12L100RB QO12-20M100/RB QO12-20M100TF/S QO12M100/RB QO16-20M100/RB QO16M100/RB QO20M100/RB QO112L125G/RB QO112-24L125G/RB QO112-24L125GWGC QO116L125G QO116-24L125G/RB QO12-24L125/RB QO120-24L125G QO120-24L125GWGC QO120L125G QO124L125G/RB QO124M125/RB QO16L125/RB QO16-12M125FTRB QO16-24L125/RB QO20L125/RB QO20-24L125/RB QO24L125/RB QO120-30L150G QO120-30M150/RB QO124L150G QO124M150 QO130L150G/RB QO130M150/RB QO16L150/RB QO16M150/RB QO16-30L150/RB QO18-16M150FTRB QO20-30M150/RB QO20-30M150TF/S QO20-30L150 QO24L150/RB QO24M150/RB QO30L150/RB QO30M150/RB QO8-16M200FT/RB QO112L200G/RB QO120-40M200/RB QO120-40M200TC QO124M200 QO130L200G/RB QO130-40M200 QO130M200/RB QO130-40L200G/RB QO140M200/RB QO16L200/RB QO16M200/RB QO18-16M200FTRB QO20-40L200/RB QO20-40M200TF/S QO20-40M200/RB QO24L200/RB QO24M200/RB QO30L200/RB QO30M200/RB QO30-40L200/RB QO30-40M200/RB QO40M200/RB QO140M225 QO142L225G/RB MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. Product Category RESI a UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting. One or two load conductors. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-23 Circuit Breakers Main and Branch Circuit Breakersa Breaker Type Ampere Rating Catalog Number Catalog Number UL Interrupting Ratings (kA) QN 150 2-Pole 175 120/240V AC 200 QN2150 QN2175n QN2200 QN2150Rb 10 QN2175Rbn 10 QN2200Rb 10 QNH 150 2-Pole 175 120/240V AC 200 HQN 150 2-Pole 175 120/240V AC 200 QN2150H QN2175Hn QN2200H HQN2150 HQN2175n HQN2200 QN2150RHb 22 QN2175RHbn 22 QN2200RHb 22 HQN2150Rb 65 -- 65 HQN2200Rb 65 Requires 4 panel spaces, 2 adjacent and 2 opposite. SHIPPING: 1 per carton (Wt. 3 lbs.) Main Breaker Kits For use in Ultimate Load Centersd UL Type Ampere Catalog Rating Number EQ8681 100 MBK100A EQ8682 125 MBK125A EQ8693 150 MBK150A -- -- -- EQ8695 200 MBK200A EQ8696 225 MBK225A For use in EQIII Load Centers UL Type Ampere Catalog Rating Number EQ9675 100 MBK100 EQ9677 125 EQ9683 150 MBK125 MBK150 EQ9684 175 MBK175n EQ9685 200 EQ9686 225 MBK200 MBK225 UL Interrupting Ratings (kA) 22 22 22 22 22 22 Breaker Type QPJc 3-Pole 240V AC Ampere Rating 125 150 200 Catalog Number QPJ3125 QPJ3150 QPJ3200 UL Interrupting Ratings (kA) 10 10 10 Requires 6 spaces due to cross over design. Fits only EQIII 125-400A 3-phase load centers SHIPPING: 5 per carton (Wt. 17 lbs.) Breaker Type QPP 2-Pole 120/240V AC QPPH 2-Pole 120/240V AC HQPH 2-Pole, 120/240V AC HQPP 2-Pole 120/240V AC HQPPH 2-Pole 120/240V AC Ampere Rating 125 150 175 200 225 125 150 175 200 225 100 125 125 150 175 200 225 100 125 150 175 200 225 Catalog Number Q2125B Q2150B Q2175Bn Q2200B Q2225B Q2125BH Q2150BH Q2175BHn Q2200BH Q2225BHn HQ2100H HQ2125H Obsolete Obsolete UL Interrupting Breaker Ratings (kA) Volts AC 120/240 10 10 10 10 10 22 22 22 22 22 100 100 Revised on 10/31/18 Selection QNRe QNe EQ9675 MBK (100,125)A MBK (150,200,225)A QPJ 2-Pole QPP MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. n Built to order. Allow 23 weeks for delivery. a All circuit breakers on this page are common trip. b Reverse handle. c CSA Listed. d MBK100A for use in 100 and 125A load centers. MBK125A for use in 125A load centers. MBK150A for use in 150, 200 and 225A load centers. MBK200A for use in 200 and 225A load centers. MBK225A for use in 225A load centers. MBK175A for use in 200 and 225A load centers. e QNR required for horizontal applications or vertical applications where the lugs are facing up. The QN breaker is required for vertical applications where the lugs are facing down as shown. 7-24 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category RESI Circuit Breakers Main and Branch Circuit Breakers QS Breaker PowerMod's core offering of residential Meter Stacks, type WMM, offers the widest product offering & flexibility in the industry. Each meter stack houses the QuickSystem features to maximize productivity and minimize labor costs. To further simplify installation, our 225 Amp meter stacks feature the QS breaker. The QS breaker adds to the Siemens exclusive feature set in our Power Mod product line. Benefits and part numbers include: An exclusive side wired design saves wiring space and eliminates difficult "S bends" No need for costly filler plates -- QS 225 Amp breaker takes the same space as standard 100 Amp QPs Single right hand bend wiring - saves time and wire Provides 100K AIC flexibility from 100 up to 225 Amps 10K to 100K AIC Series Rating QS Breaker Breaker Type Amperage 100 110 125 150 175 200 225 QS 10K AIC QS2100 QS2110 QS2125 QS2150 QS2175 QS2200 QS2225 QSH 22K AIC QS2100H QS2110H QS2125H QS2150H QS2175H QS2200H QS2225H QSHH 42K AIC QSH2100 QSH2110 QSH2125 QSH2150 QSH2175 QSH2200 QSH2225 HQS 65K AIC QS2100HH QS2110HH QS2125HH QS2150HH QS2175HH QS2200HH QS2225HH HQSH 100K AIC HQS2100H HQS2110H HQS2125H HQS2150H HQS2175H HQS2200H HQS2225H 1.00 .19 QS Breaker Dimension Drawing .58 .96 1.38 CAUTION PRECAUCION Revised on 10/31/18 Front View MOLDED CASE 7 CIRCUIT BREAKERS 2.01 2.38 2.56 2.66 7.89 4.31 ON NEUTRAL OFF 20 2.22 .99 20 .19 1.39 1.34 .37 000A 000000 .28 .16 1.06 1.16 2.12 For PowerMod information, please refer to Section 2, page 2-49 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-25 Circuit Breakers Line Diagrams 1-Pole 2-Pole 3" 23/8" 3-Pole 31/8" QP, QPH, HQP Dimension Drawings Type QT Type QPF, QPHF, QE, QAF2, QAF2H Type EQ8681, EQ8682 Type EQ8693, EQ8695, EQ8696 Type QPJ MOLDED CASE 7 CIRCUIT BREAKERS Type QN, QNH, HQN Type QNR, QNRH, HQNR a All standard circuit breakers are calibrated to 40°C maximum ambient application. 7-26 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Type QPP, QPPH, HQPP, HQPPH Circuit Breakers Lug Data Circuit Breaker Type QP, QPH, HQP, Plug-in QP 1 & 2-Pole Only QT QPF, QPHF QAF2, QAFH2, QFGA2, QFGAH2 QD QN, QNH, HQN QS, QSH, QSHH, HQS, HQSH EQ8681-Ultimate, PL, ES EQ8682-Ultimate, PL, ES EQ8693-Ultimate, PL, ES EQ8695-Ultimate, PL, ES EQ8696-Ultimate, PL, ES QPP, QPPH, HQPP, HQPPH EQ9675-EQIII EQ9677-EQIII EQ9683-EQIII EQ9684 EQ9685-EQIII EQ9686-EQIII QPJ Circuit Breaker Ampere Rating LOAD SIDE 10 1535 4050 55-125 55-60 1535 40 4050 Exception: 1 & 2-pole QP at 55-60 1530 4060 1520 1520 1520 2535 4060 150200 100225 100 125 150 200 225 125 150 175 200 225 100 125 150 175 200 225 125200 Cables Per Connector 1 or 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Revised on 10/31/18 Connector Wire Range Reference #14-#16 AWG Cu #14#6 AWG Cu #14#6 AWG Al #8#6 AWG Cu #8#4 AWG Al #8-#2/0 AWG Cu #8-#2/0 AWG Al #6-#4 AWG Cu-Al (#3 AWG compatible with QPH & HQP) #14#6 AWG Cu #14#6 AWG Al #8 AWG CU-Al #8#6 AWG Cu #8#4 AWG Al #14#10 AWG Cu #12#8 AWG Al #8#6 AWG Cu #8#4 AWG Al #14#12 AWG Cu #12#10 AWG Al #14#10 AWG Cu Only #14#12 AWG Cu #12#10 AWG Al #10#8 AWG Cu #10#6 AWG Al #8#6 AWG Cu #8#4 AWG Al #1300kcmil Cu-Al #3300kcmil Cu-Al #43/0 AWG Cu-Al #43/0 AWG Cu-Al #1300kcmil Cu-Al #1300kcmil Cu-Al #1300kcmil Cu-Al #1 AWG Cu #2/0 AWG Al #1/0 AWG Cu #3/0 AWG Al #2/0 AWG Cu #4/0 AWG Al #3/0 AWG Cu 250kcmil AWG Al #4/0 AWG Cu 300kcmil AWG Al #8-#2/0 AWG Cu #8-#2/0 AWG Al #8-#2/0 AWG Cu #8-#2/0 AWG Al #1/0 AWG Cu #3/0 AWG Al #3/0 AWG Cu 250kcmil AWG Al #2/0 AWG Cu #4/0 AWG Al #4/0 AWG Cu 300kcmil AWG Al #2300kcmil Cu-Al MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-27 Surge Protection Circuit Breaker and Surge Protective Device (SPD) Features n 2 inch wide plug-on design -- Includes (2) 1 Pole circuits breakers -- No loss of load center spaces n Easy to install and perfect for retrofit n LEDs provide protection status Benefits By installing a Siemens Circuit Breaker and Surge Protective Device (SPD) in the load center of the residence, surge protection is provided for all branch circuits. Two green LED indicator lights are provided to show that surge protection is provided for all circuits connected to the load center. These breakers should be used for circuit protection of frequently used household or facility circuits because the lights and devices connected to these circuits provide an effective indication that surge protection is being provided. The circuit breaker and SPD utilize Siemens-built 150V AC, 40mm, metal oxide varistors (MOVs). The maximum impulse rating for the SPD module is 40kA. The standard interrupting rating for the circuit breakers is 10k AIC. All Type QP circuit breakers and SPD are plug-on style, with load terminals provided. The devices are rated for 120/240V AC and are calibrated for 40 degrees C maximum ambient applications. Breaker Type QP 1- Pole 120/240V AC 10K AIC Ampere Rating (2) 15 (2) 20 Catalog Number QSA1515SPD QSA2020SPD Surge Type SPD SPD Catalog Number Amperage Number of Poles Initial Clamping Level Transient Energy Rating Transient Suppression Voltage Rating Peak Current Rating (impulse) Discharge Voltage Characteristic Discharge Current Withstand Rating Circuit Breaker Interrupting Rating Listings/Certifications QSA1515SPD QSA2020SPD 15 or 20 Amp (2) 1-Pole Circuit Breakers 240 Volts 360 Joules line-to-neutral 720 Joules line-to-line 500 volts peak, line-to-neutral 1000 volts peak, line-to-line 40,000 amperes @ 1,500A, 600 volts @ 5,000A, 800 volts (both line-to-neutral) 10,000 amperes line-to-neutral 10,000A, 120/240V AC UL, CSA Meets UL 1449 4th Edition Circuit Breaker and Surge Protective Device (SPD) MOLDED CASE 7 CIRCUIT BREAKERS For warranty information please refer to the surge website www.usa.siemens.com/surge 7-28 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category RESI Molded Case Circuit Breakers Revised on 04/30/21 Panelboard Mounting with INSTA-WIRE Selection 1-Pole Bolt-On (120/240V AC)e Type BLa Cont. Current Rating 10,000A IR @ 40° C Catalog No. Type BT (Tandem) 10,000A IR Catalog No. Type BLHa 22,000A IR Catalog No. 10 B110 15 B115d 20 B120d 25 B125 30 B130 35 B135 40 B140 45 B145n 50 B150 60 B160 70 B170 -- B1515 B2020 -- -- -- -- -- -- -- -- -- B115Hd B120Hd B125H B130H B135Hn B140H B145Hn B150H B160Hn B170Hn 2-Pole Bolt-On (Common-Trip 120/240V AC)f Type BLa Cont. Current Rating 10,000A IR @ 40° C Catalog No. Type BLHa 22,000A IR Catalog No. 10 B210 15 B215 20 B220 25 B225 30 B230 35 B235 40 B240 45 B245 50 B250 60 B260 70 B270 80 B280 90 B290 100 B2100 110 B2110n 125 B2125 -- B215H B220H B225Hn B230H B235Hn B240H B245Hn B250H B260H B270Hn B280Hn B290Hn B2100H B2110Hn B2125H 2-Pole Bolt-On (Common-Trip 240V AC)cf 15 B215R -- 20 B220R -- 30 B230R -- 40 B240Rn -- 50 B250R -- 3-Pole Bolt-On (Common-Trip 240V AC)g 15 B315 20 B320 25 B325 30 B330 35 B335 40 B340 45 B345 50 B350 60 B360 70 B370 80 B380 90 B390 100 B3100 B315H B320H B325H B330H B335Hn B340H B345Hn B350H B360H B370H B380Hn B390Hn B3100H Type BTH (Tandem) 22,000A IR Catalog No. -- B1515H B2020H -- -- -- -- -- -- -- -- Type HBLa 65,000A IR Catalog No. -- B115HHd B120HHd B125HHn B130HH B135HHn B140HH B145HHn B150HHn B160HHn B170HHn Type HBLa 65,000A IR Catalog No. -- B215HH B220HH B225HHn B230HH B235HHn B240HH B245HHn B250HH B260HH B270HHn B280HHn B290HHn B2100HH B2110HHn B2125HHn -- -- -- -- -- B315HH B320HH B325HHn B330HH B335HHn B340HH B345HHn B350HH B360HH B370HH B380HH B390HH B3100HH BL/BLH/HBL Internal Accessories Description Catalog Number 120VAC Shunt Trip add suffix...00S01n 24VAC Shunt Trip 120V Auxiliary Switch add suffix...00S07n add suffix...01nb Field/Factory Installed Factory Factory Factory For external accessories, please refer to page 7-161 n Built to order. Allow 2-3 weeks for delivery a UL Listed for use with 60/75° wire through 40 amps, UL listed for use with 75° wire only for 50 amps and above, HACR rated. 120V AC Fluorescent Lighting. b1A and 1B contacts. cUL Listed for use on 3-phase grounded "B" systems -- 10,000 for this application. dUL Listed for frequent switching applications (SWD). eShipped 12 per sleeve. fShipped 6 per sleeve. gShipped 4 per sleeve. hULListed 5KAIR. 1-Pole 2-Pole 3-Pole Breaker Dimensions Type Amp. L D1 D2 BL, BLH 15-50 3 9/16 2 3/8 3 BL, BLH 55-125 3 3/4 2 3/8 3 HBL 15-125 3 3/4 2 3/8 3 BT, BTH 15-20 3 3/4 2 3/8 3 Modifications Description 400Hz Calibration Marine 50°C Ambient Calibration Fungus Proofing Catalog No. add suffix...Yh add suffix...M add suffix...F i10 Amp breaker does not have INSTA-WIRE. jFor 3 Phase Applications. UL Listed for reverse feed. It is the installers responsibility to ensure that there is adequate neutral connections available in the panel before installing these breakers. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-29 MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers Panelboard Mounting Circuit Breakers Arc-Fault Circuit Interrupters (AFCI) AFCI's detect arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. The device is intended to mitigate the effects of arcing faults by functioning to de-energize the circuit when an arcfault is detected. Combination Type AFCI Detects all three possible types of arc fault: line-to-ground, line-to-neutral, and series. Breaker Type BAF2/BAFH2/HBAF2 1-Pole 120V AC BAF/BAFH 2-Pole 120/240V AC Ampere Rating 15 20 15 20 10,000 A IR Catalog Number BA115AFCa BA120AFCa B215AFCa B220AFCa 22,000 A IR Catalog Number BA115AFCHn BA120AFCHn B215AFCHn B220AFCHn 65,000 A IR Catalog Number BA115AFCHHn BA120AFCHHn -- -- Dual Function AFCI/GFCI The Dual Function Circuit Breaker combines Combination Type AFCI and GFCI, protecting against both Arc Faults and (5mA) Ground Faults. The device includes the Self Test feature, making it the first in class in electrical safety for homeowners. BFGA2/BFGAH2/ HBFGA2 1-Pole 120V AC 15 B115DF 20 B120DF B115DFHn B120DFHn B115DFHHn B120DFHHn Ground-Fault Circuit Interrupters (GFCI) Provides Class A (5mA) ground fault protection. Intended for personnel protection. De-energizes the circuit for all ungrounded conductors of the circuit. Breaker Amp 10k A IR Type Rating Cat. No. BLF2/ BLHF2 1-Pole 120V AC Bolt-On 15 20 25 30 BF115Aa BF120Aa BF125A BF130A 22k A IR Cat. No. BF115AHa BF120AHa BF125AHn BF130AH 65k A IR Cat. No. BF115AHHn BF120AHHn BF125AHHn BF130AHHn BLF/ 15 BLHF 20 2-Pole 30 120/240V 40 AC 50 Bolt-On 60 BF215 A BF220 A BF230 A BF240 A BF250 A BF260 A BF215AHn -- BF220AH -- BF230AH -- BF240AHn -- BF250AHn -- BF260AHn -- Ground Fault Equipment Protection (30mA) Provides protection of equipment from damaging line-to-ground faults currents. De-energizes the circuit for all ungrounded conductors of the circuit. Breaker Amp 10k A IR 22k A IR Type Rating Cat. No. Cat. No. BLE/ BLEH 15 1-Pole, 20 120V AC 30 Bolt-On BE115 a BE115Hna BE120 a BE120Hna BE130 BE130Hn BLE/ 15 BLEH 20 2-Pole 30 120/240V 40 AC 50 Bolt-On 60 BE215 BE220 BE230 BE240 BE250 BE260 BE215Hn BE220Hn BE230Hn BE240Hn BE250Hn BE260Hn Revised on 09/30/19 · UL Listed Selection · HACR Rated 1-Pole Combination Type AFCI 2-Pole Combination Type AFCI 1-Pole Dual Function AFCI/GFC BAF2/BLF2/BLE Accessories Description Padlocking Device 1-Pole Padlocking Device 2-Pole Handle Block Catalog Number ECPLD1 ECPLD2 ECBX231M Wiring Diagrams 1-Pole Equipment Protection 2-Pole Equipment Protection MOLDED CASE 7 CIRCUIT BREAKERS n Built to order. Allow 8 -10 weeks for delivery. a UL Listed as SWD (Switching Duty) Rated, suitable for 120V AC Fluorescent Lighting. 7-30 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Panelboard Mounting Circuit Breakers Special Application Breakers Switching Neutralsa Breaker Type Ampere Rating BLG 15 2-Wire 20 Common Trip BLG 3-Wire 30 Common Trip Catalog Number BG215 n BG220 n BG330 n HID Lightinga For high-intensity discharge lamp loads having in-rush currents above the instantaneous trip setting of a standard breaker. 15 BL 20 1-Pole 30 B115HID bn B120HID b B130HID n 15 BL 20 2-Pole 30 B215HID bn B220HID b B230HID n Molded Case Switch For applications that do not require overcurrent protection. BL 30 2-Pole B230S 2-Wire Selection 3-Wire Switching Neutrals MOLDED CASE 7 CIRCUIT BREAKERS n Built to order. Allow 23 weeks for delivery. a H ACR rated. b U L Listed for frequent switching applications (SWD). 120V AC fluorescent lighting. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-31 Molded Case Circuit Breakers BQD 100A Frame Panelboard Mounting Circuit Breakers BQDd Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 1-Pole 277V AC125V DC Catalog Number BQD115 a b BQD120 a b BQD125 b BQD130 b BQD135b BQD140b BQD145bn BQD150b BQD160 BQD170n BQD180n BQD190n BQD1100n 2-Polec 480Y/277V AC 125/250V DC Catalog Number BQD215e BQD220e BQD225e BQD230e BQD235e BQD240e BQD245e BQD250e BQD260 BQD270 BQD280 BQD290 BQD2100 3-Polec 480Y/277V AC Catalog Number BQD315e BQD320e BQD325e BQD330e BQD335e BQD340e BQD345e BQD350e BQD360 BQD370 BQD380 BQD390 BQD3100 BQD6 CSA Certified Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 1-Pole 347V AC Catalog Number BQD6115 a BQD6120 a BQD6125n BQD6130 BQD6135n BQD6140n BQD6145n BQD6150n BQD6160n BQD6170n 2-Polec 600/347V AC Catalog Number BQD6215 BQD6220 BQD6225n BQD6230 BQD6235n BQD6240n BQD6245n BQD6250n BQD6260n BQD6270n 3-Polec 600/347V AC Catalog Number BQD6315 BQD6320 BQD6325n BQD6330 BQD6335n BQD6340 BQD6345n BQD6350 BQD6360 BQD6370 Interrupting Ratings (max. RMS symmetrical amperes kA) UL IEC 947-2f Volts AC Volts AC Volts DC 220/240 380/415 Breaker Number 480/ 600/ 125/ Type of Poles 120 240 277 277 347 347 125 250 Icu Ics Icu Ics BQD 1-Pole 65 -- 14 -- -- -- 14 -- 18 9 -- -- 2-Pole -- 65 -- 14 -- -- -- 14 65 33 18 9 3-Pole -- 65 -- 14 -- -- -- 14 65 33 18 9 BQD6 1-Pole -- -- -- -- 10 -- 14 -- 18 9 -- -- 2-Pole -- -- -- -- -- 10 -- 14 65 33 18 9 3-Pole -- -- -- -- -- 10 -- -- 65 33 18 9 Revised on 10/31/18 Selection/Dimensions BQD, BQD6 BQD, BQD6 Shipping Weights Number of Poles 1 2 3 Number per Carton 1/12/48 1/6/24 1/4/16 Shipping Weight (lbs.) (ea.) 1.6 1.2 2.0 Lugs For 60/75°C Wire BQD Load End Only 1540 #14#6 AWG Cu #12#6 AWG Al 45100 #8#1 AWG Cu #6#1/0 AWG Al MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. n Built to order. Allow 23 weeks for delivery. a SWD rated for switching fluorescent lighting. b HID rated at 277V AC. c Not suitable for 3-phase delta 480V applications. d HACR rated. e HID rated at 480Y/277V AC. f Applicable for 15-30A breakers only 7-32 Siemens Industry, Inc. SPEEDFAXTM Product Catalog For external accessories, please refer to pages 7-163 to 7-168 For internal accessories, please refer to page 7-35 Product Category MCCB Molded Case Circuit Breakers Revised on 05/31/18 GB Frame Selection Type NGB Frame (Panelboard Mount) Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 1-Pole Catalog Number NGB1B015B ab NGB1B020B ab NGB1B025B b NGB1B030B b NGB1B035B b NGB1B040B b NGB1B045B b NGB1B050B b NGB1B060B NGB1B070B NGB1B080B NGB1B090B NGB1B100B NGB1B110B NGB1B125B Load lugs are included as standard. HACR rated. 2-Pole Catalog Number NGB2B015B b NGB2B020B b NGB2B025B b NGB2B030B b NGB2B035B b NGB2B040B b NGB2B045B b NGB2B050B b NGB2B060B NGB2B070B NGB2B080B NGB2B090B NGB2B100B NGB2B110B NGB2B125B 3-Pole Catalog Number NGB3B015B b NGB3B020B b NGB3B025B b NGB3B030B b NGB3B035B b NGB3B040B b NGB3B045B b NGB3B050B b NGB3B060B NGB3B070B NGB3B080B NGB3B090B NGB3B100B NGB3B110B NGB3B125B NGB1B030B Type HGB (Panelboard Mount) Type LGB (Panelboard Mount) Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 1-Pole 2-Pole 3-Pole Catalog Number HGB1B015Ba b HGB1B020Ba b HGB1B025Bb HGB1B030Bb HGB1B035Bb HGB1B040Bb HGB1B045Bb HGB1B050Bb HGB1B060B HGB1B070B HGB1B080B HGB1B090B HGB1B100B HGB1B110B HGB1B125B Catalog Number HGB2B015Bb HGB2B020Bb HGB2B025Bb HGB2B030Bb HGB2B035Bb HGB2B040Bb HGB2B045Bb HGB2B050Bb HGB2B060B HGB2B070B HGB2B080B HGB2B090B HGB2B100B HGB2B110B HGB2B125B Catalog Number HGB3B015Bb HGB3B020Bb HGB3B025Bb HGB3B030Bb HGB3B035Bb HGB3B040Bb HGB3B045Bb HGB3B050Bb HGB3B060B HGB3B070B HGB3B080B HGB3B090B HGB3B100B HGB3B110B HGB3B125B Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 1-Pole 2-Pole 3-Pole Catalog Number LGB1B015Ba b LGB1B020Ba b LGB1B025Bb LGB1B030Bb LGB1B035Bb LGB1B040Bb LGB1B045Bb LGB1B050Bb LGB1B060B LGB1B070B LGB1B080B LGB1B090B LGB1B100B LGB1B110B LGB1B125B Catalog Number LGB2B015Bb LGB2B020Bb LGB2B025Bb LGB2B030Bb LGB2B035Bb LGB2B040Bb LGB2B045Bb LGB2B050Bb LGB2B060B LGB2B070B LGB2B080B LGB2B090B LGB2B100B LGB2B110B LGB2B125B Catalog Number LGB3B015Bb LGB3B020Bb LGB3B025Bb LGB3B030Bb LGB3B035Bb LGB3B040Bb LGB3B045Bb LGB3B050Bb LGB3B060B LGB3B070B LGB3B080B LGB3B090B LGB3B100B LGB3B110B LGB3B125B Shipping Weights Number of Poles Number per Carton 1 1 2 1 3 1 Shipping Weight lbs. (kg) 0.9 (0.4) 1.9 (0.9) 2.9 (1.2) Lugs for 60/75°C Wire Type NGB HGB LGB Ampere Rating 15-30A 35-125A Wire Size #14-#6 AWG Cu #12-#6 AWG Al #8-1/0 AWG Cu #8-2/0 AWG Al Catalog Number TC1Q1 (qty. 1) 3TC1Q1 (qty. 3) 3TC1GG20 Interrupting Ratings (max. RMS symmetrical amperes kA) UL489 Volts AC Poles 120 240 277 347 480Y/277 1 100 -- 25 14 -- NGB 2,3 -- 100 -- -- 25 1 100 -- 35 14 -- HGB 2,3 -- 100 -- -- 35 1 100 -- 65 14 -- LGB 2,3 -- 100 -- -- 65 600Y/347 -- 14 -- 14 -- 14 Volts DC 125 14 -- 14 -- 14 -- 125/250 -- 14 -- 14 -- 14 MOLDED CASE 7 CIRCUIT BREAKERS a SWD rated. b HID rated. Product Category MCCB c 2-pole only. 2-pole only or two outer poles of 3-pole breaker UL Listed for reverse feed. For external accessories, please refer to pages 7-163 to 7-168 For internal accessories, please refer to page 7-35 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-33 Molded Case Circuit Breakers Revised on 04/30/21 GB2 Frame Selection Type NGB2g (Panelboard Mount) Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 1-Pole Catalog Number NGB1K015Ba b NGB1K020Ba b NGB1K025Bb NGB1K030Bb NGB1K035Bb NGB1K040Bb NGB1K045Bb NGB1K050Bb NGB1K060B NGB1K070B NGB1K080B NGB1K090B NGB1K100B NGB1K110B NGB1K125B Load lugs are included as standard. HACR rated. 2-Pole Catalog Number NGB2K015Bb NGB2K020Bb NGB2K025Bb NGB2K030Bb NGB2K035Bb NGB2K040Bb NGB2K045Bb NGB2K050Bb NGB2K060B NGB2K070B NGB2K080B NGB2K090B NGB2K100B NGB2K110B NGB2K125B 3-Pole Catalog Number NGB3K015Bb NGB3K020Bb NGB3K025Bb NGB3K030Bb NGB3K035Bb NGB3K040Bb NGB3K045Bb NGB3K050Bb NGB3K060B NGB3K070B NGB3K080B NGB3K090B NGB3K100B NGB3K110B NGB3K125B LGB3K125B Type HGB2g (Panelboard Mount) Type LGB2g (Panelboard Mount) Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 1-Pole 2-Pole 3-Pole Catalog Number HGB1K015Ba b HGB1K020Ba b HGB1K025Bb HGB1K030Bb HGB1K035Bb HGB1K040Bb HGB1K045Bb HGB1K050Bb HGB1K060B HGB1K070B HGB1K080B HGB1K090B HGB1K100B HGB1K110B HGB1K125B Catalog Number HGB2K015Bb HGB2K020Bb HGB2K025Bb HGB2K030Bb HGB2K035Bb HGB2K040Bb HGB2K045Bb HGB2K050Bb HGB2K060B HGB2K070B HGB2K080B HGB2K090B HGB2K100B HGB2K110B HGB2K125B Catalog Number HGB3K015Bb HGB3K020Bb HGB3K025Bb HGB3K030Bb HGB3K035Bb HGB3K040Bb HGB3K045Bb HGB3K050Bb HGB3K060B HGB3K070B HGB3K080B HGB3K090B HGB3K100B HGB3K110B HGB3K125B Continuous Current Rating @ 40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 1-Pole 2-Pole 3-Pole Catalog Number LGB1K015Ba b LGB1K020Ba b LGB1K025Bb LGB1K030Bb LGB1K035Bb LGB1K040Bb LGB1K045Bb LGB1K050Bb LGB1K060B LGB1K070B LGB1K080B LGB1K090B LGB1K100B LGB1K110B LGB1K125B Catalog Number LGB2K015Bb LGB2K020Bb LGB2K025Bb LGB2K030Bb LGB2K035Bb LGB2K040Bb LGB2K045Bb LGB2K050Bb LGB2K060B LGB2K070B LGB2K080B LGB2K090B LGB2K100B LGB2K110B LGB2K125B Catalog Number LGB3K015Bb LGB3K020Bb LGB3K025Bb LGB3K030Bb LGB3K035Bb LGB3K040Bb LGB3K045Bb LGB3K050Bb LGB3K060B LGB3K070B LGB3K080B LGB3K090B LGB3K100B LGB3K110B LGB3K125B Shipping Weights Number of Poles 1 2 3 Number per Carton 1 1 1 Shipping Weight lbs. (kg) .75 (.34) 1.3 (.59) 2.0 (.98) Lugs for 60/75°C Wire Type NGB2 HGB2 LGB2 Ampere Rating 15-30A 35-125A Wire Size #14-#6 AWG Cu #12-#6 AWG Al #8-2/0 AWG CU/AL Catalog Number TC1Q1 (qty. 1) 3TC1Q1 (qty. 3) 3TC1GG20 Interrupting Ratings (max. RMS symmetrical amperes kA) Type NGB2 HGB2 LGB2 Poles 1 2, 3 1 2, 3 1 2, 3 UL 489 Volts AC 120 100 -- 100 -- 100 -- 240 -- 100 -- 100 -- 100 277 25 -- 35 -- 65 -- 480 -- 25 -- 35 -- 65 347 14 -- 22 -- 25 -- 600Y/347 -- 14 -- 22 -- 25 Volts DC 125 14 -- 14 -- 14 -- 125/250 -- 14 -- 14 -- 14 a SWD rated. b HID rated. c 2-pole only. 2-pole only or two outer poles of 3-pole breaker Suitable for reverse feed applications f 3 pole breakers suitable for single phase applications g xGB2 breakers require different strap kits than xGB. Refer to Section 11 for specific catalog numbers. For external accessories, please refer to pages 7-163 to 7-168 For internal accessories, please refer to page 7-35 MOLDED CASE 7 CIRCUIT BREAKERS 7-34 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Accessoriesa Shunt Trip Control Voltage V AC 120 V DC -- 240 -- 277 -- 480 -- 600 -- -- 012 -- 024 -- 048 -- 125 BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB, LGB, NGB2, HGB2 and LGB2 Catalog Number CQDST120 CQDST240s CQDST277s CQDST480s CQDST600 CQDST12 CQDST24 CQDST48 CQDST125 Auxiliary Switch Maximum Voltage AC DC 240 125 240 125 Number of Contacts 1A1B 2A2B BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB, LGB, NGB2, HGB2 and LGB2 Catalog Number CQDA1 CQDA2 Alarm Switch Maximum Voltage AC DC BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB, LGB, NGB2, HGB2 and LGB2 Catalog Number 240 125 CQDBA Shunt Trip and Auxiliary Switch Combinations Shunt Trip Voltage AC 24 120 240 277 480 DC -- -- -- -- -- 600 -- -- 12 -- 24 -- 48 -- 125 BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB, LGB, NGB2, HGB2 and LGB2 Catalog Number CQDST24AASs CQDST120AASs CQDST240AASs CQDST277AASs CQDST480AASs CQDST600AASs CQDST12DASs CQDST24DASs CQDST48DASs CQDST125DASs Alarm and Auxiliary Switch Combinations For Breaker BQD, BQD6, CQD, CQD6, NGG, HGG, LGG, NGB, HGB, LGB, NGB2, HGB2 and LGB2 Catalog Number CQDA1BAs CQDST120AAS CQD with Accessory Installed Revised on 05/04/17 Selection MOLDED CASE 7 CIRCUIT BREAKERS s Built to order. Allow 68 weeks for delivery. aAdds 1-pole space for accessory. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-35 3VA Molded Case Circuit Breakers 3VA41 125A Thermal-magnetic Trip Circuit Breakers Revised on 01/31/21 Selection 3VA41 125A Frame, 1-Pole Thermal-Magnetic Trip Unit Cont. Amp S-Interrupting Class (SEAB) M-Interrupting Class (MEAB) H-Interrupting Class (HEAB) Rating Catalog Number Catalog Number Catalog Number TM210 FTFM 15 3VA4195-4ED14-0AA0a b 3VA4195-5ED14-0AA0a b 3VA4195-6ED14-0AA0a b 20 3VA4120-4ED14-0AA0a b 3VA4120-5ED14-0AA0a b 3VA4120-6ED14-0AA0a b 25 3VA4125-4ED14-0AA0b 3VA4125-5ED14-0AA0b 3VA4125-6ED14-0AA0b 30 3VA4130-4ED14-0AA0b 3VA4130-5ED14-0AA0b 3VA4130-6ED14-0AA0b 35 3VA4135-4ED14-0AA0b 3VA4135-5ED14-0AA0b 3VA4135-6ED14-0AA0b 40 3VA4140-4ED14-0AA0b 3VA4140-5ED14-0AA0b 3VA4140-6ED14-0AA0b 45 3VA4145-4ED14-0AA0b 3VA4145-5ED14-0AA0b 3VA4145-6ED14-0AA0b 50 3VA4150-4ED14-0AA0b 3VA4150-5ED14-0AA0b 3VA4150-6ED14-0AA0b 60 3VA4160-4ED14-0AA0 3VA4160-5ED14-0AA0 3VA4160-6ED14-0AA0 70 3VA4170-4ED14-0AA0 3VA4170-5ED14-0AA0 3VA4170-6ED14-0AA0 80 3VA4180-4ED14-0AA0 3VA4180-5ED14-0AA0 3VA4180-6ED14-0AA0 90 3VA4190-4ED14-0AA0 3VA4190-5ED14-0AA0 3VA4190-6ED14-0AA0 100 3VA4110-4ED14-0AA0 3VA4110-5ED14-0AA0 3VA4110-6ED14-0AA0 110 3VA4111-4ED14-0AA0 3VA4111-5ED14-0AA0 3VA4111-6ED14-0AA0 125 3VA4112-4ED14-0AA0 3VA4112-5ED14-0AA0 3VA4112-6ED14-0AA0 3VA41 125A Frame, 1 in 2-Pole Thermal-Magnetic Trip Unit Cont. Amp S-Interrupting Class (SEAB) Rating Catalog Number 15 3VA4195-4ED54-0AA0a b 20 3VA4120-4ED54-0AA0a b 25 3VA4125-4ED54-0AA0b 30 3VA4130-4ED54-0AA0b 35 3VA4135-4ED54-0AA0b 40 3VA4140-4ED54-0AA0b 45 3VA4145-4ED54-0AA0b 50 3VA4150-4ED54-0AA0b 60 3VA4160-4ED54-0AA0 70 3VA4170-4ED54-0AA0 80 3VA4180-4ED54-0AA0 90 3VA4190-4ED54-0AA0 100 3VA4110-4ED54-0AA0 110 3VA4111-4ED54-0AA0 125 3VA4112-4ED54-0AA0 M-Interrupting Class (MEAB) Catalog Number TM210 FTFMa 3VA4195-5ED54-0AA0a b 3VA4120-5ED54-0AA0a b 3VA4125-5ED54-0AA0b 3VA4130-5ED54-0AA0b 3VA4135-5ED54-0AA0b 3VA4140-5ED54-0AA0b 3VA4145-5ED54-0AA0b 3VA4150-5ED54-0AA0b 3VA4160-5ED54-0AA0 3VA4170-5ED54-0AA0 3VA4180-5ED54-0AA0 3VA4190-5ED54-0AA0 3VA4110-5ED54-0AA0 3VA4111-5ED54-0AA0 3VA4112-5ED54-0AA0 H-Interrupting Class (HEAB) Catalog Number 3VA4195-6ED54-0AA0a b 3VA4120-6ED54-0AA0a b 3VA4125-6ED54-0AA0b 3VA4130-6ED54-0AA0b 3VA4135-6ED54-0AA0b 3VA4140-6ED54-0AA0b 3VA4145-6ED54-0AA0b 3VA4150-6ED54-0AA0b 3VA4160-6ED54-0AA0 3VA4170-6ED54-0AA0 3VA4180-6ED54-0AA0 3VA4190-6ED54-0AA0 3VA4110-6ED54-0AA0 3VA4111-6ED54-0AA0 3VA4112-6ED54-0AA0 3VA41 125A Frame, 2-Pole Thermal-Magnetic Trip Unit Cont. Amp S-Interrupting Class (SEAB) M-Interrupting Class (MEAB) H-Interrupting Class (HEAB) Rating Catalog Number Catalog Number Catalog Number TM210 FTFM 15 3VA4195-4ED24-0AA0a b 3VA4195-5ED24-0AA0a b 3VA4195-6ED24-0AA0a b 20 3VA4120-4ED24-0AA0a b 3VA4120-5ED24-0AA0a b 3VA4120-6ED24-0AA0a b 25 3VA4125-4ED24-0AA0b 3VA4125-5ED24-0AA0b 3VA4125-6ED24-0AA0b 30 3VA4130-4ED24-0AA0b 3VA4130-5ED24-0AA0b 3VA4130-6ED24-0AA0b 35 3VA4135-4ED24-0AA0b 3VA4135-5ED24-0AA0b 3VA4135-6ED24-0AA0b 40 3VA4140-4ED24-0AA0b 3VA4140-5ED24-0AA0b 3VA4140-6ED24-0AA0b 45 3VA4145-4ED24-0AA0b 3VA4145-5ED24-0AA0b 3VA4145-6ED24-0AA0b 50 3VA4150-4ED24-0AA0b 3VA4150-5ED24-0AA0b 3VA4150-6ED24-0AA0b 60 3VA4160-4ED24-0AA0 3VA4160-5ED24-0AA0 3VA4160-6ED24-0AA0 70 3VA4170-4ED24-0AA0 3VA4170-5ED24-0AA0 3VA4170-6ED24-0AA0 80 3VA4180-4ED24-0AA0 3VA4180-5ED24-0AA0 3VA4180-6ED24-0AA0 90 3VA4190-4ED24-0AA0 3VA4190-5ED24-0AA0 3VA4190-6ED24-0AA0 100 3VA4110-4ED24-0AA0 3VA4110-5ED24-0AA0 3VA4110-6ED24-0AA0 110 3VA4111-4ED24-0AA0 3VA4111-5ED24-0AA0 3VA4111-6ED24-0AA0 125 3VA4112-4ED24-0AA0 3VA4112-5ED24-0AA0 3VA4112-6ED24-0AA0 a SWD rated. b HID rated. 7-36 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA41 125A 1-Pole 3VA41 125A 1 in 2-Pole 3VA41 125A 2-Pole Ordering Information The catalog number listed here are for complete, non-interchangable trip circuit breakers with load lugs installed. 3VA4 breakers up to 40A include 3VA9133-0JB10 lugs. 45A to 125A breakers include 3VA9133-0JB11 lugs. All 3VA41 thermal-magnetic trip circuit breakers are UL listed for reverse feed applications. For NAVAL-rated 1, 2 or 3-P thermalmagnetic trip circuit breakers, change the 13th digit of the catalog number to the number "1". (For example, a 35KA @480VAC, 40A, 3-pole, NAVAL rated 3VA41 would be catalog number 3VA4140-5ED31-1AA0) MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers Revised on 06/30/21 3VA41 125A Thermal-magnetic Trip Circuit Breakers Selection 3VA41 125A Frame, 3-Pole Thermal-Magnetic Trip Unit Cont. Amp S-Interrupting Class (SEAB) M-Interrupting Class (MEAB) H-Interrupting Class (HEAB) Rating Catalog Number Catalog Number Catalog Number TM210 FTFM 15 3VA4195-4ED34-0AA0a b 3VA4195-5ED34-0AA0a b 3VA4195-6ED34-0AA0a b 20 3VA4120-4ED34-0AA0a b 3VA4120-5ED34-0AA0a b 3VA4120-6ED34-0AA0a b 25 3VA4125-4ED34-0AA0b 3VA4125-5ED34-0AA0b 3VA4125-6ED34-0AA0b 30 3VA4130-4ED34-0AA0b 3VA4130-5ED34-0AA0b 3VA4130-6ED34-0AA0b 35 3VA4135-4ED34-0AA0b 3VA4135-5ED34-0AA0b 3VA4135-6ED34-0AA0b 40 3VA4140-4ED34-0AA0b 3VA4140-5ED34-0AA0b 3VA4140-6ED34-0AA0b 45 3VA4145-4ED34-0AA0b 3VA4145-5ED34-0AA0b 3VA4145-6ED34-0AA0b 50 3VA4150-4ED34-0AA0b 3VA4150-5ED34-0AA0b 3VA4150-6ED34-0AA0b 60 3VA4160-4ED34-0AA0 3VA4160-5ED34-0AA0 3VA4160-6ED34-0AA0 3VA41 125A 3-Pole 70 3VA4170-4ED34-0AA0 3VA4170-5ED34-0AA0 3VA4170-6ED34-0AA0 80 3VA4180-4ED34-0AA0 3VA4180-5ED34-0AA0 3VA4180-6ED34-0AA0 90 3VA4190-4ED34-0AA0 3VA4190-5ED34-0AA0 3VA4190-6ED34-0AA0 100 3VA4110-4ED34-0AA0 3VA4110-5ED34-0AA0 3VA4110-6ED34-0AA0 Trip Settings for 3VA41 TM210 - FTFM 110 3VA4111-4ED34-0AA0 3VA4111-5ED34-0AA0 3VA4111-6ED34-0AA0 In (A) Ir (A) Ii (A) 125 3VA4112-4ED34-0AA0 3VA4112-5ED34-0AA0 Interrupting Ratings for 3VA41 3VA4112-6ED34-0AA0 15 15 20 20 25 25 RMS Symmetrical Amperes (kA) 30 30 Inter- Volts AC (50/60 Hz) Volts DC 35 35 40 40 rupting Breaker 480Y/ 600Y/ Class Type Poles 120 240 277 347 277V 480 347V 125 250 45 45 50 50 1 65 S SEAB 25 14 14 60 60 M 2, 3 MEAB 1 2, 3 85 65 85 35 18 25 35 25 35 14 18 A3VcAc2e5UssLoMrieo58sl05daenddCSapsaereCPiracrutsit B87r00eakers 90 70 80 90 H HEAB 1 150 2, 3 150 65 25 65 65 Inte3r0nal accessories 25 100 100 110 100 110 Design 125 125 Dimensions Shipping Weight 300 300 300 300 350 400 450 500 600 700 800 900 1000 1100 1250 Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg 3VA41 1 1 (25.4) 5.1 (129.4) 3.6 (92.2) 0.62 0.28 3VA41 1 in 2 2 (50.8) 5.1 (129.4) 3.6 (92.2) 0.94 0.43 3VA41 2 2 (50.8) 5.1 (129.4) 3.6 (92.2) 1.13 0.51 3VA41 3 3 (76.2) 5.1 (129.4) 3.6 (92.2) 1.64 0.74 Connectors for 75C Wire for 3VA41 Type Steel wrap around (Cu cable only), 1 cable lugs Aluminum body lug small (Cu/Al cable), 1 cable lug Aluminum body lug (Cu/Al cable), 1 cable lugs Aluminum body lug small with control wire tap (Cu/Al cable), 1 cable lug Aluminum body lug with control wire tap (Cu/Al cable), 1 cable lugs Copper body lug small (Cu cable only), 1 cable lugs Copper body lug (Cu cable only), 1 cable lugs Copper body lug small with control wire tap (Cu cable only), 1 cable lugs Copper body lug with control wire tap (Cu cable only), 1 cable lugs Min. Max. Catalog No. cable size cable size (kit of 3 lugs) AWG 14 3/0 3VA9133-0JA11 AWG 14 AWG 8 3VA9133-0JB10c AWG 8 3/0 3VA9133-0JB11d AWG 14 AWG 8 3VA9133-0JG10c AWG 8 3/0 3VA9133-0JG11d AWG 14 AWG 8 3VA9133-0JD10c AWG 8 2/0 3VA9133-0JD11d AWG 14 AWG 8 AWG 8 2/0 4 3VA9133-0JK10c 3VA9133-0JK11d 3VA4 Accessories Description Padlocking Device for 3VA4 breaker Catalog Number 3VA9038-0LB11 a SWD rated. b HID rated. c Use these lugs on 15A to 40A breakers. d Use these lugs on 45A to 125A breakers. Internal accessories configuration 3VA4/3VA5 125 A 1 in 2-pole /2-pole 3VA4 125 A 3-pole Auxiliary switch Auxiliary switch Leading changeover switch Alarm switch Trip alarm switch Short circuit alarm switch Auxiliary release Shunt trip flexible Shunt trip left Residual current release Undervoltage release Universal release Other Cylinder lock (type Ronis) Slot No.: Type AUX_HQ AUX_HQ_el AUX_HP LCS_HQ LCS_HQ_el LCS_HP Type TAS_HQ TAS_HQ_el TAS_HP SAS_HQ SAS_HQ_el Type STF STL STL_el RCR UVR UNI 125 A 23 22 21 xxx xxx x x xx xx x x x x x 125 A 23 22 21 11 12 13 xxx xxx x x xxx xxx x x x x x xx xx x xx xx x x x x x x Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-37 MOLDED CASE 7 CIRCUIT BREAKERS Circuit Breakers Revised on 10/31/18 Lug-In/Lug-Out with INSTA-WIRE Selection All BQ/BQH/HBQ circuit breakers are supplied with load side lugs. If line side lugs are required, add suffix "L" to catalog number. Consult Siemens for any additional charge. All standard circuit breakers are calibrated for 40°C maximum ambient application. Continuous Current Rating @ 40° C Type BQ 10,000A IR Catalog Number Type BQH 22,000A IR Catalog Number 1-Pole (120/240V AC)e 15 BQ1B015d BQ1B015Hd 20 BQ1B020d BQ1B020Hd 25 BQ1B025 BQ1B025Hn 30 BQ1B030 BQ1B030H 35 BQ1B035n BQ1B035Hn 40 BQ1B040 BQ1B040H 45 BQ1B045n -- 50 BQ1B050 BQ1B050H 60 BQ1B060n BQ1B060Hn 70 BQ1B070n BQ1B070Hn 2-Pole (Common-Trip 120/240V AC)f 15 BQ2B015 BQ2B015H 20 BQ2B020 BQ2B020H 25 BQ2B025 BQ2B025Hn 30 BQ2B030 BQ2B030H 35 BQ2B035 BQ2B035Hn 40 BQ2B040 BQ2B040H 45 BQ2B045 -- 50 BQ2B050 BQ2B050H 60 BQ2B060 BQ2B060H 70 BQ2B070 BQ2B070Hn 80 BQ2B080 BQ2B080Hn 90 BQ2B090 BQ2B090Hn 100 BQ2B100 BQ2B100H 110 BQ2B110 -- 125 BQ2B125 BQ2B125H 2-Pole (Common-Trip 240V AC)cf 15 BQ2H015 -- 20 BQ2H020 -- 30 BQ2H030 -- 40 BQ2H040n -- 50 BQ2H050 -- 60 BQ2H060 -- 70 BQ2H070n -- 80 BQ2H080n -- 90 BQ2H090n -- 100 BQ2H100n -- 3-Pole (Common-Trip 240V AC)g 15 BQ3B015 BQ3B015H 20 BQ3B020 BQ3B020H 25 BQ3B025n BQ3B025Hn 30 BQ3B030 BQ3B030H 35 BQ3B035n BQ3B035H 40 BQ3B040 BQ3B040H 45 BQ3B045n BQ3B045H 50 BQ3B050 BQ3B050H 60 BQ3B060 BQ3B060H 70 BQ3B070 BQ3B070H 80 BQ3B080 BQ3B080Hn 90 BQ3B090 BQ3B090Hn 100 BQ3B100 BQ3B100H Type HBQ 65,000A IR Catalog Number HB1B015nd HB1B020nd HB1B025n HB1B030n HB1B035n HB1B040n HB1B045n HB1B050n HB1B060n HB1B070n HB2B015n HB2B020n HB2B025n HB2B030n HB2B035n HB2B040n HB2B045n HB2B050n HB2B060n HB2B070n HB2B080 HB2B090n HB2B100 HB2B110n HB2B125 -- -- -- -- -- -- -- -- -- -- HB3B015n HB3B020n HB3B025 HB3B030 HB3B035 HB3B040 HB3B045 HB3B050 HB3B060 HB3B070n HB3B080n HB3B090n HB3B100 BQ / BQH / HBQ Internal Accessories Description Catalog Number Field/Factory Installed 120VAC Shunt Trip add suffix...00S01n Factory 24VAC Shunt Trip add suffix...00S07n Factory 120V Auxiliary Switch add suffix...01nb Factory 1-Pole 2-Pole 3-Pole Factory Modifications Description Catalog Number Line Side Lugs add suffix...L Quick Connect Lug add suffix...QX 400Hz Calibration add suffix...Y h Marine 50° C Ambient Calibration add suffix...M Fungus Proofing add suffix...F For external accessories, please refer to page 7-161 MOLDED CASE 7 CIRCUIT BREAKERS n Built to order. Allow 2-3 weeks for delivery a UL Listed for use with 60/75° wire through 40 amps, UL listed for use with 75° wire only for 50 amps and above, HACR rated. b 1A and 1B contacts. c UL Listed for use on 3-phase grounded "B" systems -- 10,000 for this application. d UL Listed for frequent switching applications (SWD). 120V AC Fluorescent Lighting. 7-38 Siemens Industry, Inc. SPEEDFAXTM Product Catalog e Shipped 12 per sleeve. f Shipped 6 per sleeve. g Shipped 4 per sleeve. h ULListed 5KAIR. Refer to Table A on page 7-156 Product Category MCCB Molded Case Circuit Breakers Revised on 11/30/19 DIN Rail Mounted Circuit Breakers Selection/Dimensions Breaker Type Ampere Catalog Rating Number 1-Pole DIN Rail (120/240V AC) 10 BQ1B010QLD 15 BQ1B015QLD 20 BQ1B020QLD BQLD 1-Pole 120V DIN Rail 25 BQ1B025QLD 30 BQ1B030QLD 35 BQ1B035QLD 40 BQ1B040QLD 45 BQ1B045QLD 50 BQ1B050QLD 60 BQ1B060QLD 10 BQ1B010QXD 15 BQ1B015QXD 20 BQ1B020QXD BQXD 1-Pole 120V DIN Rail 25 BQ1B025QXD 30 BQ1B030QXD 35 BQ1B035QXD 40 BQ1B040QXD 45 BQ1B045QXD 50 BQ1B050QXD 60 BQ1B060QXD 2-Pole DIN Rail (120/240V AC) 10 BQ2B010QLD 15 BQ2B015QLD 20 BQ2B020QLD BQLD 2-Pole 25 BQ2B025QLD 30 BQ2B030QLD 120/240V 35 BQ2B035QLD DIN Rail 40 BQ2B040QLD 45 BQ2B045QLD 50 BQ2B050QLD 60 BQ2B060QLD 10 BQ2B010QXD 15 BQ2B015QXD 20 BQ2B020QXD BQXD 25 BQ2B025QXD 2-Pole 30 BQ2B030QXD 120/240V 35 BQ2B035QXD DIN Rail 40 BQ2B040QXD 45 BQ2B045QXD 50 BQ2B050QXD 60 BQ2B060QXD Line Side Load Side Connector Connector Interrupting Ratings (KA) (RMS Symmetrical Amperes) Volts AC 120 120/240 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TA1Q1 TA1Q1 10 TA1Q1 TA1Q1 10 TA1Q1 TA1Q1 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TA1Q1 Quick-Connect 10 TA1Q1 Quick-Connect 10 TA1Q1 Quick-Connect 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TC1Q1 TC1Q1 10 TA1Q1 TA1Q1 10 TA1Q1 TA1Q1 10 TA1Q1 TA1Q1 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TC1Q1 Quick-Connect 10 TA1Q1 Quick-Connect 10 TA1Q1 Quick-Connect 10 TA1Q1 Quick-Connect 10 BQ1B015QLD BQ2B015QLD BQ1B015QXD BQ2B015QXD Lugs-For Use with BQXD Circuit Breaker Amp. Rtg. Line Side 1040 45125 Cab. Per Lug 1 1 1 1 Lug Wire Range AWG #16#6 Cu #12#6 Al #8#1 Cu #6#1/0 Al Catalog Number TC1Q1ab TA1Q1 Finger Safe Terminal Shield Protects against accidental contact with lugs1 per lug. Fits line and load end. Catalog Number BQFS2 BQFS1K Qty 2 1000 BQ Enclosures Type Catalog Number d 1 EB3100S c 3R WB3100 BQ Breaker Dimensions Number of Poles Breaker Type 1, 2 BQ 1, 2 BQH, HBQ 1, 2 BQ, BQH, HBQ 3 BQ, BQH, HBQ 1, 2 BQXD Dimensions (inches) Amperes L D1 D2 15-50 3¾ 23/8 3 15-50 4 23/8 3 55-125 4 23/8 3 15-100 4 23/8 3 15-60 4½ 23/8 3 MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. n Built to order. Allow 23 weeks for delivery. a UL Listed for use with 60/75° wire through 40 amps, UL listed for use with 75° wire only for 50 amps and above, HACR rated. Product Category MCCB bConnector has steel construction. cSurface mounted indoor. If flush mounting is required, replace suffix "S" in catalog number with suffix "F". Neutral included in enclosure. Enclosure will not accept circuit breakers with shunt trips or auxiliary switches installed. Type BQXD uses TA1Q1 or TC1Q1 lugs on line side of circuit breaker. Enclosures, see Section 6 For external accessories, please refer to pages 7-161, 7-163 to 7-168 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-39 Molded Case Circuit Breakers QR 250A Frame Continuous Current Rating @ 40°C Type QR2b 100 125 150 175 200 225 250 Type QRH2b 100 125 150 175 200 225 250 Type HQR2b 100 125 150 175 200 225 250 Type HQR2Hb 100 125 150 175 200 225 250 2-Pole 240V AC Catalog Number QR22B100 QR22B125 QR22B150 QR22B175 QR22B200 QR22B225 QR22B250 QRH22B100n QRH22B125 QRH22B150 QRH22B175n QRH22B200 QRH22B225 QRH22B250 HQR22B100n HQR22B125 HQR22B150 HQR22B175n HQR22B200 HQR22B225 HQR22B250 HQR22B100H HQR22B125H HQR22B150H HQR22B175H HQR22B200H HQR22B225H HQR22B250H 3-Pole 240V AC Catalog Number QR23B100 QR23B125 QR23B150 QR23B175 QR23B200 QR23B225 QR23B250 QRH23B100 QRH23B125 QRH23B150 QRH23B175 QRH23B200 QRH23B225 QRH23B250 HQR23B100 HQR23B125 HQR23B150 HQR23B175 HQR23B200 HQR23B225 HQR23B250 HQR23B100H HQR23B125H HQR23B150H HQR23B175H HQR23B200H HQR23B225H HQR23B250H Revised on 05/04/17 Selection/Dimensions Ordering Information Load side 3TA1QR300 lugs are mounted and included when circuit breaker is ordered. For line and load lugs (3TA1QR300) installed at no additional charge, add suffix "L" to catalog number. 50°C Calibration - See page 7-159. 400HZ. - See page 7-159. Shipping Weights Number of Poles Number per Carton 2 1 3 1 Shipping Weight (lbs.) 3.2 4.5 Lugs For 75°C Wirea Catalog Number 3TA1QR300 Lug Lug Body Wire Range Al #3 - 300 Kcmil Al/Cu 3TC1QR250 Cu #3 - 300 Kcmil Cu ONLY CCQ250 CMP #6 AWG - 350kcmil Al/Cu Enclosures (Neutral Included) Type Catalog Number 1 QR2N1S or QR2N1F 3R QR2N3R3 12 QR2N12 4X QR2N4X 4X316 QR2N4X316 UL 489 Interrupting Ratings Breaker Type QR2 RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240 10 QRH2 25 HQR2 65 HQR2H 100 MOLDED CASE 7 CIRCUIT BREAKERS 7'' 3'' 2-pole 2D.53'' 4.5'' 3-pole n Built to order. Allow 23 weeks for delivery. a See Note: A page 7-150. Note: QR breakers are UL Listed for reverse feed applications. b HACR rated. 7-40 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Enclosures Section 6 For external accessories, please refer to pages 7-163 to 7-168 Product Category MCCB Molded Case Circuit Breakers QR Accessories Shunt Trip Control Voltage AC DC -- 24 120 - 240 48 In Rush 1.1A 2.0A AC / 1.8A DC Shunt Trip Catalog Number S07QR2 S01QR2 Shunt Trip and Auxiliary Switch Combination Catalog Number S07QR2A S01QR2A Auxiliary Switch Contains (1) or (2) sets of "A" contacts and "B" contacts Maximum Control Maximum Allowable Single Auxiliary 1A -1B Double Auxiliary 2A - 2B Supply Voltage (V) Current (A) Contact Catalog Number Contact Catalog Number 250 AC /125 DC 5 AC / 0.5 DC A01QR2 A02QR2 External Accessories Description Padlock Device Mounting Screw Kit Handle Blocking Device Handle Sliding-bar Interlock Catalog Number HPLQR MSQR3 HBLQR SBMIQR Revised on 04/10/17 Selection PaPdalodPcalokdclDkoecDvkeicDveiecvHeiPcHeLPQHLRQPLRQR HaHnadHnleadnlBedlolBeclokBclDkoecDvkeicDveiecvHeiBcHeLBQHLRQBLRQR MeMcehMcahenacichnaaiclnaInilctIaenlrtIlenortcleokrclSkoBcSMkBISMQBIRMQRIQR MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-41 Molded Case Circuit Breakers CQD 100A Frame Type CQD (Cable In - Cable Out) DIN Rail Mountc Continuous Current Rating @ 40°C 115 120 125 130 135 140 145 150 160 170 180 190 100 1-Pole 277V AC 125V DC Catalog Number CQD115 ab CQD120 ab CQD125 b CQD130 b CQD135bn CQD140bn CQD145bn CQD150bn CQD160n CQD170n CQD180n CQD190n CQD1100n 2-Pole 480Y/277V AC 125/250V DC Catalog Number CQD215b CQD220b CQD225b CQD230b CQD235bn CQD240b CQD245bn CQD250b CQD260 CQD270 CQD280 CQD290n CQD2100 3-Pole 480Y/277V AC Catalog Number CQD315b CQD320b CQD325b CQD330b CQD335b CQD340b CQD345bn CQD350b CQD360 CQD370 CQD380 CQD390 CQD3100 Interrupting Ratings (max. RMS symmetrical amperes kA) UL IEC 947-2d Volts AC Volts AC Volts DC 220/240 380/415 Breaker Number 480/ 600/ 125/ Type of Poles 120 240 277 277 347 125 250 Icu Ics Icu Ics CQD 1-Pole 65 -- 14 -- -- 14 -- 18 9---- 2-Pole -- 65 -- 14 -- -- 14 65 33 18 9 3-Pole -- 65 -- 14 -- -- 14 65 33 18 9 Revised on 05/31/18 Selection/Dimensions Shipping Weights Number of Poles Number per Carton 1 1 2 1 3 1 Shipping Weight lbs. (kg) 0.5 (0) 1.0 (0) 1.5 (1) Lugs For 60/75°C Wire Amps 1540 45100 Wire Size #14#6 AWG Cu #12#6 AWG Al #8#1 AWG Cu #6#1/0 AWG Al CQD CQD MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. n Built to order. Allow 23 weeks for delivery. a SWD rated. Note: CQD breakers are UL Listed for reverse feed applications. b HID rated. c HACR rated. d Applicable for 15-30A breakers only. 7-42 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Enclosures Section 6 Accessories pages 7-44 and 7-163 to 7-168 Product Category MCCB Molded Case Circuit Breakers Revised on 10/31/21 GG 125A Frame Selection/Dimensions Type NGG (Cable In - Cable Out) Continuous Current Rating @ 40°C 1-Pole Catalog Number 2-Pole Catalog Number 3-Pole Catalog Number 15 NGG1B015La b NGG2B015Lb NGG3B015Lb 20 NGG1B020La b NGG2B020Lb NGG3B020Lb 25 NGG1B025Lb NGG2B025Lb NGG3B025Lb 30 NGG1B030Lb NGG2B030Lb NGG3B030Lb 35 NGG1B035Lb NGG2B035Lb NGG3B035Lb 40 NGG1B040Lb NGG2B040Lb NGG3B040Lb 45 NGG1B045Lb NGG2B045Lb NGG3B045Lb 50 NGG1B050Lb NGG2B050Lb NGG3B050Lb 60 NGG1B060L NGG2B060L NGG3B060L GG 2.9 70 NGG1B070L NGG2B070L NGG3B070L 80 NGG1B080L NGG2B080L NGG3B080L 90 NGG1B090L NGG2B090L NGG3B090L 5.4 100 NGG1B100L NGG2B100L NGG3B100L 110 NGG1B110L NGG2B110L NGG3B110L 125 NGG1B125L NGG2B125L NGG3B125L Line and load lugs are included as standard. If no lugs are required, remove the "L" suffix. HACR rated. GG Suitable for screws or DIN rail mounting. Type HGG (Cable In - Cable Out) Type LGG (Cable In - Cable Out) Continuous Current Rating 1-Pole 2-Pole 3-Pole @ 40°C Catalog Number Catalog Number Catalog Number Continuous Current Rating 1-Pole 2-Pole @ 40°C Catalog Number Catalog Number 15 HGG1B015Lb HGG2B015Lb HGG3B015Lb 20 HGG1B020Lb HGG2B020Lb HGG3B020Lb 25 HGG1B025Lb HGG2B025Lb HGG3B025Lb 30 HGG1B030Lb HGG2B030Lb HGG3B030Lb 35 HGG1B035Lb HGG2B035Lb HGG3B035Lb 40 HGG1B040Lb HGG2B040Lb HGG3B040Lb 45 HGG1B045Lb HGG2B045Lb HGG3B045Lb 50 HGG1B050Lb HGG2B050Lb HGG3B050Lb 60 HGG1B060L HGG2B060L HGG3B060L 70 HGG1B070L HGG2B070L HGG3B070L 80 HGG1B080L HGG2B080L HGG3B080L 90 HGG1B090L HGG2B090L HGG3B090L 100 HGG1B100L HGG2B100L HGG3B100L 110 HGG1B110L HGG2B110L HGG3B110L 125 HGG1B125L HGG2B125L HGG3B125L 15 LGG1B015Lb LGG2B015Lb 20 LGG1B020Lb LGG2B020Lb 25 LGG1B025Lb LGG2B025Lb 30 LGG1B030Lb LGG2B030Lb 35 LGG1B035Lb LGG2B035Lb 40 LGG1B040Lb LGG2B040Lb 45 LGG1B045Lb LGG2B045Lb 50 LGG1B050Lb LGG2B050Lb 60 LGG1B060L LGG2B060L 70 LGG1B070L LGG2B070L 80 LGG1B080L LGG2B080L 90 LGG1B090L LGG2B090L 100 LGG1B100L LGG2B100L 110 LGG1B110L LGG2B110L 125 LGG1B125L LGG2B125L 3-Pole Catalog Number LGG3B015Lb LGG3B020Lb LGG3B025Lb LGG3B030Lb LGG3B035Lb LGG3B040Lb LGG3B045Lb LGG3B050Lb LGG3B060L LGG3B070L LGG3B080L LGG3B090L LGG3B100L LGG3B110L LGG3B125L Shipping Weights Number of Poles Number per Carton 1 1 2 1 3 1 Shipping Weight lbs. (kg) .75 (0.34) 1.3 (0.59) 2.0 (0.98) Lugs For 60/75°C Wire NGG Ampere Rating Wire Size 1530A #14#6 AWG Cu #12#6 AWG Al 35125A #8-2/0 AWG CU/AL Catalog Number TC1Q1 (qty. 1) 3TC1Q1 (qty. 3) 3TC1GG20 (qty. 3) 15125A Nut Keeper plate w/ screw (for crimp terminals) TNKG3 (qty. 3) Interrupting Ratings (max. RMS symmetrical amperes kA) Breaker Type NGG HGG LGG Poles 1 2,3 1 2,3 1 2,3 UL489 Volts AC 120 65 -- 65 -- 65 -- 240 -- 65 -- 65 -- 65 277 25 -- 35 -- 65 -- 347 14 -- 14 -- 14 -- 480 -- 25 -- 35 -- 65 600Y/347 -- 14 -- 14 -- 14 Volts DC 125 14 -- 14 -- 14 -- 125/250 -- 14 -- 14 -- 14 IEC 60947-2 (Ics = 50%Icu) Volts AC Volts DC 240 415 125/250 25 -- -- 65 -- 14 -- -- -- -- -- -- -- -- -- -- -- -- For inches / millimeters conversion, see Application Data section. a SWD rated. b HID rated at 15-50A 1-pole @ 277 VAC; 2 & 3-pole @ 480 VAC Enclosures Section 6 Accessories pages 7-44 and 7-163 to 7-168 Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-43 MOLDED CASE 7 CIRCUIT BREAKERS MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers Accessoriesa Shunt Trip Control Voltage V AC 120 V DC -- 240 -- 277 -- 480 -- 600 -- -- 012 -- 024 -- 048 -- 125 BQD, BQD6, CQD, NGG, HGG, LGG, NGB, HGB and LGB Catalog Number CQDST120 CQDST240s CQDST277s CQDST480s CQDST600 CQDST12 CQDST24 CQDST48 CQDST125 Auxiliary Switch Maximum Voltage AC DC 240 125 240 125 Number of Contacts 1A1B 2A2B BQD, BQD6, CQD, NGG, HGG, LGG, NGB, HGB and LGB Catalog Number CQDA1 CQDA2 Alarm Switch Maximum Voltage AC DC BQD, BQD6, CQD, NGG, HGG, LGG, NGB, HGB and LGB Catalog Number 240 125 CQDBA Shunt Trip and Auxiliary Switch Combinations Shunt Trip Voltage AC 24 120 240 277 480 DC -- -- -- -- -- 600 -- -- 12 -- 24 -- 48 -- 125 BQD, BQD6, CQD, NGG, HGG, LGG, NGB, HGB and LGB Catalog Number CQDST24AASs CQDST120AASs CQDST240AASs CQDST277AASs CQDST480AASs CQDST600AASs CQDST12DASs CQDST24DASs CQDST48DASs CQDST125DASs Alarm and Auxiliary Switch Combinations For Breaker BQD, BQD6, CQD, NGG, HGG, LGG, NGB, HGB and LGB Catalog Number CQDA1BAs CQDST120AAS CQD with Accessory Installed s Built to order. Allow 68 weeks for delivery. aAdds 1-pole space for accessory. 7-44 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Selection Product Category MCCB Molded Case Circuit Breakers Notes MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-45 3VA Molded Case Circuit Breakers Revised on 10/31/20 3VA UL Circuit Breakers Catalog Numbering Logic Breaker Designation 3VA 6 Catalog Numbering System 1 40 5 HL 3 1 0 A A0 Breaker Designation Thermal magnetic panelboard breakers 4 Thermal magnetic (Cable-in Cable-out) breakers 5 Electronic trip breakers 6 Frame Size 125/150A 1 250A 2 400A 3 600A 4 800A 5 1000A 6 Rated Current 3VA41/ 3VA51 3VA52 3VA53 3VA54 3VA55 3VA61 3VA62 3VA63 3VA64 3VA65 3VA66 15A 95 20A 200A 200A 20 225A 225A 22 25A 250A 250A 250A 250A 25 30A 300A 30 35A 350A 35 40A 40A 400A 40A 400A 400A 40 45A 45A 450A 45 50A 50A 500A 50 60A 60A 600A 600A 600A 600A 60 70A 70A 700A 70 80A 80A 800A 800A 80 90A 90A 90 100A 100A 100A 100A 1000A 10 110A 110A 11 125A 125A 12 150A 150A 15 175A 17 Interrupting Capacity @ 480V 3VA4/3VA5 3VA6 MCP/MCS 200K 0 MCP/MCS MCP/MCS 1 25K 4 35K 35K 5 65K 65K 6 100K 100K 7 150K 8 Trip Unit Protection Functions (see next page for details) Number of Poles (see next page for details) Connection Technology (see next page for details) Regional Specifics (as applicable) (see next page for details) Auxiliary Releases (see next page for details) Auxiliary/Alarm Switches (see next page for details) 7-46 Siemens Industry, Inc. SPEEDFAXTM Product Catalog MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers Revised on 01/31/21 3VA UL Circuit Breakers Catalog Numbering System Catalog Numbering Logic (cont.) 3VA 6 1 Breaker Designation (see previous page for details) Trip Unit Protection Functions 3VA4/3VA5 L I TM230 MCCB fix adj TM210 MCCB fix fix TM240 MCCB adj adj TM230 MCCB fix adj TM210 MCCB fix fix TM240 MCCB adj adj TM110M MSP fix TM120M MSP adj TM120M MSP adj MCS110 MSC fix 3VA6 L S ETU320 LI MCCB adj ETU330 LIG MCCB adj ETU350 LSI MCCB adj adj ETU550 LSI MCCB adj adj ETU556 LSI(G) MCCB adj adj ETU560 LSIG MCCB adj adj ETU820 LI MCCB adj ETU830 LIG MCCB adj ETU850LSI MCCB adj adj ETU856 LSI(G) MCCB adj adj ETU860 LSIG MCCB adj adj ETU310M MCP MCS110 MCS N 100% 100% 100% I G N LCD adj 0%/50%/100% adj adj 0%/50%/100% fix 0%/50%/100% adj 20/40%...100/160% yes adj alarm 20/40%...100/160% yes adj adj 20/40%...100/160% yes adj 20/40%...100/160% yes adj adj 20/40%...100/160% yes adj 20/40%...100/160% yes adj alarm 20/40%...100/160% yes adj adj 20/40%...100/160% yes adj fix 40 5 HL 3 com. yes yes yes yes yes yes yes yes EC ED EF GC GD GF MG MH MU BB measurement values HL HM HN standard JP standard JT standard JQ advanced KL advanced KM advanced KP advanced KT advanced KQ MS BB 1 0 A A0 Number of Poles 1 pole 1 2 pole 2 3 pole 3 4 pole 4 1-in-2 pole 5 2-in-3 pole 6 Connection Technology No wire connector 1 Nut keeper kit, line and load 2 Nut keeper kit, load end only 3 Aluminum wire connector, load end only 4 Wire connector, line end only 5 Wire connector, line and load 6 Regional Specifics (as applicable) Standard 0 NAVAL/50C 1 100% Rated (3VA6) 2 Auxiliary Releases Without A Auxiliary/Alarm Switches Without A0 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-47 3VA Molded Case Circuit Breakers 3VA41 125A Thermal-magnetic Trip Circuit Breakers Revised on 01/31/21 Selection 3VA41 125A Frame, 1-Pole Thermal-Magnetic Trip Unit Cont. Amp S-Interrupting Class (SEAB) M-Interrupting Class (MEAB) H-Interrupting Class (HEAB) Rating Catalog Number Catalog Number Catalog Number TM210 FTFM 15 3VA4195-4ED14-0AA0a b 3VA4195-5ED14-0AA0a b 3VA4195-6ED14-0AA0a b 20 3VA4120-4ED14-0AA0a b 3VA4120-5ED14-0AA0a b 3VA4120-6ED14-0AA0a b 25 3VA4125-4ED14-0AA0b 3VA4125-5ED14-0AA0b 3VA4125-6ED14-0AA0b 30 3VA4130-4ED14-0AA0b 3VA4130-5ED14-0AA0b 3VA4130-6ED14-0AA0b 35 3VA4135-4ED14-0AA0b 3VA4135-5ED14-0AA0b 3VA4135-6ED14-0AA0b 40 3VA4140-4ED14-0AA0b 3VA4140-5ED14-0AA0b 3VA4140-6ED14-0AA0b 45 3VA4145-4ED14-0AA0b 3VA4145-5ED14-0AA0b 3VA4145-6ED14-0AA0b 50 3VA4150-4ED14-0AA0b 3VA4150-5ED14-0AA0b 3VA4150-6ED14-0AA0b 60 3VA4160-4ED14-0AA0 3VA4160-5ED14-0AA0 3VA4160-6ED14-0AA0 70 3VA4170-4ED14-0AA0 3VA4170-5ED14-0AA0 3VA4170-6ED14-0AA0 80 3VA4180-4ED14-0AA0 3VA4180-5ED14-0AA0 3VA4180-6ED14-0AA0 90 3VA4190-4ED14-0AA0 3VA4190-5ED14-0AA0 3VA4190-6ED14-0AA0 100 3VA4110-4ED14-0AA0 3VA4110-5ED14-0AA0 3VA4110-6ED14-0AA0 110 3VA4111-4ED14-0AA0 3VA4111-5ED14-0AA0 3VA4111-6ED14-0AA0 125 3VA4112-4ED14-0AA0 3VA4112-5ED14-0AA0 3VA4112-6ED14-0AA0 3VA41 125A Frame, 1 in 2-Pole Thermal-Magnetic Trip Unit Cont. Amp S-Interrupting Class (SEAB) Rating Catalog Number 15 3VA4195-4ED54-0AA0a b 20 3VA4120-4ED54-0AA0a b 25 3VA4125-4ED54-0AA0b 30 3VA4130-4ED54-0AA0b 35 3VA4135-4ED54-0AA0b 40 3VA4140-4ED54-0AA0b 45 3VA4145-4ED54-0AA0b 50 3VA4150-4ED54-0AA0b 60 3VA4160-4ED54-0AA0 70 3VA4170-4ED54-0AA0 80 3VA4180-4ED54-0AA0 90 3VA4190-4ED54-0AA0 100 3VA4110-4ED54-0AA0 110 3VA4111-4ED54-0AA0 125 3VA4112-4ED54-0AA0 M-Interrupting Class (MEAB) Catalog Number TM210 FTFMa 3VA4195-5ED54-0AA0a b 3VA4120-5ED54-0AA0a b 3VA4125-5ED54-0AA0b 3VA4130-5ED54-0AA0b 3VA4135-5ED54-0AA0b 3VA4140-5ED54-0AA0b 3VA4145-5ED54-0AA0b 3VA4150-5ED54-0AA0b 3VA4160-5ED54-0AA0 3VA4170-5ED54-0AA0 3VA4180-5ED54-0AA0 3VA4190-5ED54-0AA0 3VA4110-5ED54-0AA0 3VA4111-5ED54-0AA0 3VA4112-5ED54-0AA0 H-Interrupting Class (HEAB) Catalog Number 3VA4195-6ED54-0AA0a b 3VA4120-6ED54-0AA0a b 3VA4125-6ED54-0AA0b 3VA4130-6ED54-0AA0b 3VA4135-6ED54-0AA0b 3VA4140-6ED54-0AA0b 3VA4145-6ED54-0AA0b 3VA4150-6ED54-0AA0b 3VA4160-6ED54-0AA0 3VA4170-6ED54-0AA0 3VA4180-6ED54-0AA0 3VA4190-6ED54-0AA0 3VA4110-6ED54-0AA0 3VA4111-6ED54-0AA0 3VA4112-6ED54-0AA0 3VA41 125A Frame, 2-Pole Thermal-Magnetic Trip Unit Cont. Amp S-Interrupting Class (SEAB) M-Interrupting Class (MEAB) H-Interrupting Class (HEAB) Rating Catalog Number Catalog Number Catalog Number TM210 FTFM 15 3VA4195-4ED24-0AA0a b 3VA4195-5ED24-0AA0a b 3VA4195-6ED24-0AA0a b 20 3VA4120-4ED24-0AA0a b 3VA4120-5ED24-0AA0a b 3VA4120-6ED24-0AA0a b 25 3VA4125-4ED24-0AA0b 3VA4125-5ED24-0AA0b 3VA4125-6ED24-0AA0b 30 3VA4130-4ED24-0AA0b 3VA4130-5ED24-0AA0b 3VA4130-6ED24-0AA0b 35 3VA4135-4ED24-0AA0b 3VA4135-5ED24-0AA0b 3VA4135-6ED24-0AA0b 40 3VA4140-4ED24-0AA0b 3VA4140-5ED24-0AA0b 3VA4140-6ED24-0AA0b 45 3VA4145-4ED24-0AA0b 3VA4145-5ED24-0AA0b 3VA4145-6ED24-0AA0b 50 3VA4150-4ED24-0AA0b 3VA4150-5ED24-0AA0b 3VA4150-6ED24-0AA0b 60 3VA4160-4ED24-0AA0 3VA4160-5ED24-0AA0 3VA4160-6ED24-0AA0 70 3VA4170-4ED24-0AA0 3VA4170-5ED24-0AA0 3VA4170-6ED24-0AA0 80 3VA4180-4ED24-0AA0 3VA4180-5ED24-0AA0 3VA4180-6ED24-0AA0 90 3VA4190-4ED24-0AA0 3VA4190-5ED24-0AA0 3VA4190-6ED24-0AA0 100 3VA4110-4ED24-0AA0 3VA4110-5ED24-0AA0 3VA4110-6ED24-0AA0 110 3VA4111-4ED24-0AA0 3VA4111-5ED24-0AA0 3VA4111-6ED24-0AA0 125 3VA4112-4ED24-0AA0 3VA4112-5ED24-0AA0 3VA4112-6ED24-0AA0 a SWD rated. b HID rated. 7-48 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA41 125A 1-Pole 3VA41 125A 1 in 2-Pole 3VA41 125A 2-Pole Ordering Information The catalog number listed here are for complete, non-interchangable trip circuit breakers with load lugs installed. 3VA4 breakers up to 40A include 3VA9133-0JB10 lugs. 45A to 125A breakers include 3VA9133-0JB11 lugs. All 3VA41 thermal-magnetic trip circuit breakers are UL listed for reverse feed applications. For NAVAL-rated 1, 2 or 3-P thermalmagnetic trip circuit breakers, change the 13th digit of the catalog number to the number "1". (For example, a 35KA @480VAC, 40A, 3-pole, NAVAL rated 3VA41 would be catalog number 3VA4140-5ED31-1AA0) MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers Revised on 06/30/21 3VA41 125A Thermal-magnetic Trip Circuit Breakers Selection 3VA41 125A Frame, 3-Pole Thermal-Magnetic Trip Unit Cont. Amp S-Interrupting Class (SEAB) M-Interrupting Class (MEAB) H-Interrupting Class (HEAB) Rating Catalog Number Catalog Number Catalog Number TM210 FTFM 15 3VA4195-4ED34-0AA0a b 3VA4195-5ED34-0AA0a b 3VA4195-6ED34-0AA0a b 20 3VA4120-4ED34-0AA0a b 3VA4120-5ED34-0AA0a b 3VA4120-6ED34-0AA0a b 25 3VA4125-4ED34-0AA0b 3VA4125-5ED34-0AA0b 3VA4125-6ED34-0AA0b 30 3VA4130-4ED34-0AA0b 3VA4130-5ED34-0AA0b 3VA4130-6ED34-0AA0b 35 3VA4135-4ED34-0AA0b 3VA4135-5ED34-0AA0b 3VA4135-6ED34-0AA0b 40 3VA4140-4ED34-0AA0b 3VA4140-5ED34-0AA0b 3VA4140-6ED34-0AA0b 45 3VA4145-4ED34-0AA0b 3VA4145-5ED34-0AA0b 3VA4145-6ED34-0AA0b 50 3VA4150-4ED34-0AA0b 3VA4150-5ED34-0AA0b 3VA4150-6ED34-0AA0b 60 3VA4160-4ED34-0AA0 3VA4160-5ED34-0AA0 3VA4160-6ED34-0AA0 3VA41 125A 3-Pole 70 3VA4170-4ED34-0AA0 3VA4170-5ED34-0AA0 3VA4170-6ED34-0AA0 80 3VA4180-4ED34-0AA0 3VA4180-5ED34-0AA0 3VA4180-6ED34-0AA0 90 3VA4190-4ED34-0AA0 3VA4190-5ED34-0AA0 3VA4190-6ED34-0AA0 100 3VA4110-4ED34-0AA0 3VA4110-5ED34-0AA0 3VA4110-6ED34-0AA0 Trip Settings for 3VA41 TM210 - FTFM 110 3VA4111-4ED34-0AA0 3VA4111-5ED34-0AA0 3VA4111-6ED34-0AA0 In (A) Ir (A) Ii (A) 125 3VA4112-4ED34-0AA0 3VA4112-5ED34-0AA0 Interrupting Ratings for 3VA41 3VA4112-6ED34-0AA0 15 15 20 20 25 25 RMS Symmetrical Amperes (kA) 30 30 Inter- Volts AC (50/60 Hz) Volts DC 35 35 40 40 rupting Breaker 480Y/ 600Y/ Class Type Poles 120 240 277 347 277V 480 347V 125 250 45 45 50 50 1 65 S SEAB 25 14 14 60 60 M 2, 3 MEAB 1 2, 3 85 65 85 35 18 25 35 25 35 14 18 A3VcAc2e5UssLoMrieo58sl05daenddCSapsaereCPiracrutsit B87r00eakers 90 70 80 90 H HEAB 1 150 2, 3 150 65 25 65 65 Inte3r0nal accessories 25 100 100 110 100 110 Design 125 125 Dimensions Shipping Weight 300 300 300 300 350 400 450 500 600 700 800 900 1000 1100 1250 Breaker Poles W in. (mm) H in. (mm) D in. (mm) lbs. kg 3VA41 1 1 (25.4) 5.1 (129.4) 3.6 (92.2) 0.62 0.28 3VA41 1 in 2 2 (50.8) 5.1 (129.4) 3.6 (92.2) 0.94 0.43 3VA41 2 2 (50.8) 5.1 (129.4) 3.6 (92.2) 1.13 0.51 3VA41 3 3 (76.2) 5.1 (129.4) 3.6 (92.2) 1.64 0.74 Connectors for 75C Wire for 3VA41 Type Steel wrap around (Cu cable only), 1 cable lugs Aluminum body lug small (Cu/Al cable), 1 cable lug Aluminum body lug (Cu/Al cable), 1 cable lugs Aluminum body lug small with control wire tap (Cu/Al cable), 1 cable lug Aluminum body lug with control wire tap (Cu/Al cable), 1 cable lugs Copper body lug small (Cu cable only), 1 cable lugs Copper body lug (Cu cable only), 1 cable lugs Copper body lug small with control wire tap (Cu cable only), 1 cable lugs Copper body lug with control wire tap (Cu cable only), 1 cable lugs Min. Max. Catalog No. cable size cable size (kit of 3 lugs) AWG 14 3/0 3VA9133-0JA11 AWG 14 AWG 8 3VA9133-0JB10c AWG 8 3/0 3VA9133-0JB11d AWG 14 AWG 8 3VA9133-0JG10c AWG 8 3/0 3VA9133-0JG11d AWG 14 AWG 8 3VA9133-0JD10c AWG 8 2/0 3VA9133-0JD11d AWG 14 AWG 8 AWG 8 2/0 4 3VA9133-0JK10c 3VA9133-0JK11d 3VA4 Accessories Description Padlocking Device for 3VA4 breaker Catalog Number 3VA9038-0LB11 a SWD rated. b HID rated. c Use these lugs on 15A to 40A breakers. d Use these lugs on 45A to 125A breakers. Internal accessories configuration 3VA4/3VA5 125 A 1 in 2-pole /2-pole 3VA4 125 A 3-pole Auxiliary switch Auxiliary switch Leading changeover switch Alarm switch Trip alarm switch Short circuit alarm switch Auxiliary release Shunt trip flexible Shunt trip left Residual current release Undervoltage release Universal release Other Cylinder lock (type Ronis) Slot No.: Type AUX_HQ AUX_HQ_el AUX_HP LCS_HQ LCS_HQ_el LCS_HP Type TAS_HQ TAS_HQ_el TAS_HP SAS_HQ SAS_HQ_el Type STF STL STL_el RCR UVR UNI 125 A 23 22 21 xxx xxx x x xx xx x x x x x 125 A 23 22 21 11 12 13 xxx xxx x x xxx xxx x x x x x xx xx x xx xx x x x x x x Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-49 MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers 3VA51 125A Thermal-magnetic Trip Circuit Breakers Revised on 04/30/21 Selection 3VA51 125A Frame, 1-Pole Thermal-Magnetic Trip Unit Cont. Ampere Rating S-Interrupting Class (SEAS) Catalog Number M-Interrupting Class (MEAS) Catalog Number H-Interrupting Class (HEAS) Catalog Number TM210 FTFM 15 3VA5195-4ED11-0AA0 3VA5195-5ED11-0AA0 3VA5195-6ED11-0AA0 20 3VA5120-4ED11-0AA0 3VA5120-5ED11-0AA0 3VA5120-6ED11-0AA0 25 3VA5125-4ED11-0AA0 3VA5125-5ED11-0AA0 3VA5125-6ED11-0AA0 30 3VA5130-4ED11-0AA0 3VA5130-5ED11-0AA0 3VA5130-6ED11-0AA0 35 3VA5135-4ED11-0AA0 3VA5135-5ED11-0AA0 3VA5135-6ED11-0AA0 40 3VA5140-4ED11-0AA0 3VA5140-5ED11-0AA0 3VA5140-6ED11-0AA0 45 3VA5145-4ED11-0AA0 3VA5145-5ED11-0AA0 3VA5145-6ED11-0AA0 50 3VA5150-4ED11-0AA0 3VA5150-5ED11-0AA0 3VA5150-6ED11-0AA0 60 3VA5160-4ED11-0AA0 3VA5160-5ED11-0AA0 3VA5160-6ED11-0AA0 70 3VA5170-4ED11-0AA0 3VA5170-5ED11-0AA0 3VA5170-6ED11-0AA0 80 3VA5180-4ED11-0AA0 3VA5180-5ED11-0AA0 3VA5180-6ED11-0AA0 90 3VA5190-4ED11-0AA0 3VA5190-5ED11-0AA0 3VA5190-6ED11-0AA0 100 3VA5110-4ED11-0AA0 3VA5110-5ED11-0AA0 3VA5110-6ED11-0AA0 110 3VA5111-4ED11-0AA0 3VA5111-5ED11-0AA0 3VA5111-6ED11-0AA0 125 3VA5112-4ED11-0AA0 3VA5112-5ED11-0AA0 3VA5112-6ED11-0AA0 3VA51 125A Frame, 2-Pole Thermal-Magnetic Trip Unit Cont. Ampere Rating 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 S-Interrupting Class (SEAS) Catalog Number 3VA5195-4ED21-0AA0 3VA5120-4ED21-0AA0 3VA5125-4ED21-0AA0 3VA5130-4ED21-0AA0 3VA5135-4ED21-0AA0 3VA5140-4ED21-0AA0 3VA5145-4ED21-0AA0 3VA5150-4ED21-0AA0 3VA5160-4ED21-0AA0 3VA5170-4ED21-0AA0 3VA5180-4ED21-0AA0 3VA5190-4ED21-0AA0 3VA5110-4ED21-0AA0 3VA5111-4ED21-0AA0 3VA5112-4ED21-0AA0 M-Interrupting Class (MEAS) Catalog Number TM210 FTFMa 3VA5195-5ED21-0AA0 3VA5120-5ED21-0AA0 3VA5125-5ED21-0AA0 3VA5130-5ED21-0AA0 3VA5135-5ED21-0AA0 3VA5140-5ED21-0AA0 3VA5145-5ED21-0AA0 3VA5150-5ED21-0AA0 3VA5160-5ED21-0AA0 3VA5170-5ED21-0AA0 3VA5180-5ED21-0AA0 3VA5190-5ED21-0AA0 3VA5110-5ED21-0AA0 3VA5111-5ED21-0AA0 3VA5112-5ED21-0AA0 H-Interrupting Class (HEAS) Catalog Number 3VA5195-6ED21-0AA0 3VA5120-6ED21-0AA0 3VA5125-6ED21-0AA0 3VA5130-6ED21-0AA0 3VA5135-6ED21-0AA0 3VA5140-6ED21-0AA0 3VA5145-6ED21-0AA0 3VA5150-6ED21-0AA0 3VA5160-6ED21-0AA0 3VA5170-6ED21-0AA0 3VA5180-6ED21-0AA0 3VA5190-6ED21-0AA0 3VA5110-6ED21-0AA0 3VA5111-6ED21-0AA0 3VA5112-6ED21-0AA0 Interrupting Ratings for 3VA51 Interrupting Breaker Class Type Poles 1 S SEAS 2, 3, 4 M MEAS 1 2, 3, 4 1 H HEAS 2, 3, 4 RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 480Y/ 120 240 277 347 277V 480 65 25 14 65 25 25 85 35 18 85 35 35 150 50 18 150 65 65 Volts DC 600Y/ 347V 125 250 14 14 14 50 25 18 25 85 30 25 30 100 500b 600b 50 50 85 85 100 100 a Available with NAVAL/50C ratings. b Applies to 3VA51 3-Pole 7-50 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA51 125A 1-Pole 3VA51 125A 2-Pole Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers without lugs. For factory installed nut keepers (3VA91330QA00), change the 12th digit of the catalog number to "2". (For example, a 35KA @480VAC, 40A, 3-pole, 3VA51 with nut keepers would be catalog number 3VA5140-5ED32-0AA0). For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 40A, 3-pole, 3VA51 with lugs would be catalog number 3VA51405ED36-0AA0). Alternate connectors can be ordered separately for field installation. For NAVAL-rated thermal-magnetic trip circuit breakers, change the 13th digit of the catalog number to the number "1". (For example, a 35KA @480VAC, 40A, 3-pole, NAVAL rated 3VA51 would be catalog number 3VA5140-5ED31-1AA0) All 3VA51 thermal-magnetic trip circuit breakers are UL listed for reverse feed applications. MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers 3VA51 125A Thermal-magnetic Trip Circuit Breakers Revised on 04/30/21 Selection 3VA51 125A Frame, 3-Pole Thermal-Magnetic Trip Unit Cont. Ampere Rating 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 15 20 30 40 50 60 70 80 100 S-Interrupting Class (SEAS) Catalog Number 3VA5195-4ED31-0AA0 3VA5120-4ED31-0AA0 3VA5125-4ED31-0AA0 3VA5130-4ED31-0AA0 3VA5135-4ED31-0AA0 3VA5140-4ED31-0AA0 3VA5145-4ED31-0AA0 3VA5150-4ED31-0AA0 3VA5160-4ED31-0AA0 3VA5170-4ED31-0AA0 3VA5180-4ED31-0AA0 3VA5190-4ED31-0AA0 3VA5110-4ED31-0AA0 3VA5111-4ED31-0AA0 3VA5112-4ED31-0AA0 3VA5195-4EC31-0AA0 3VA5120-4EC31-0AA0 3VA5125-4EC31-0AA0 3VA5130-4EC31-0AA0 3VA5135-4EC31-0AA0 3VA5140-4EC31-0AA0 3VA5145-4EC31-0AA0 3VA5150-4EC31-0AA0 3VA5160-4EC31-0AA0 3VA5170-4EC31-0AA0 3VA5180-4EC31-0AA0 3VA5190-4EC31-0AA0 3VA5110-4EC31-0AA0 3VA5111-4EC31-0AA0 3VA5112-4EC31-0AA0 3VA5195-4EF31-0AA0 3VA5120-4EF31-0AA0 3VA5130-4EF31-0AA0 3VA5140-4EF31-0AA0 3VA5150-4EF31-0AA0 3VA5160-4EF31-0AA0 3VA5170-4EF31-0AA0 3VA5180-4EF31-0AA0 3VA5110-4EF31-0AA0 M-Interrupting Class (MEAS) Catalog Number TM210 FTFMa 3VA5195-5ED31-0AA0 3VA5120-5ED31-0AA0 3VA5125-5ED31-0AA0 3VA5130-5ED31-0AA0 3VA5135-5ED31-0AA0 3VA5140-5ED31-0AA0 3VA5145-5ED31-0AA0 3VA5150-5ED31-0AA0 3VA5160-5ED31-0AA0 3VA5170-5ED31-0AA0 3VA5180-5ED31-0AA0 3VA5190-5ED31-0AA0 3VA5110-5ED31-0AA0 3VA5111-5ED31-0AA0 3VA5112-5ED31-0AA0 TM230 FTAMa 3VA5195-6EC31-0AA0 3VA5120-5EC31-0AA0 3VA5125-5EC31-0AA0 3VA5130-5EC31-0AA0 3VA5135-5EC31-0AA0 3VA5140-5EC31-0AA0 3VA5145-5EC31-0AA0 3VA5150-5EC31-0AA0 3VA5160-5EC31-0AA0 3VA5170-5EC31-0AA0 3VA5180-5EC31-0AA0 3VA5190-5EC31-0AA0 3VA5110-5EC31-0AA0 3VA5111-5EC31-0AA0 3VA5112-5EC31-0AA0 TM240 ATAM 3VA5195-5EF31-0AA0 3VA5120-5EF31-0AA0 3VA5130-5EF31-0AA0 3VA5140-5EF31-0AA0 3VA5150-5EF31-0AA0 3VA5160-5EF31-0AA0 3VA5170-5EF31-0AA0 3VA5180-5EF31-0AA0 3VA5110-5EF31-0AA0 H-Interrupting Class (HEAS) Catalog Number 3VA5195-6ED31-0AA0 3VA5120-6ED31-0AA0 3VA5125-6ED31-0AA0 3VA5130-6ED31-0AA0 3VA5135-6ED31-0AA0 3VA5140-6ED31-0AA0 3VA5145-6ED31-0AA0 3VA5150-6ED31-0AA0 3VA5160-6ED31-0AA0 3VA5170-6ED31-0AA0 3VA5180-6ED31-0AA0 3VA5190-6ED31-0AA0 3VA5110-6ED31-0AA0 3VA5111-6ED31-0AA0 3VA5112-6ED31-0AA0 3VA5195-6EC31-0AA0 3VA5120-6EC31-0AA0 3VA5125-6EC31-0AA0 3VA5130-6EC31-0AA0 3VA5135-6EC31-0AA0 3VA5140-6EC31-0AA0 3VA5145-6EC31-0AA0 3VA5150-6EC31-0AA0 3VA5160-6EC31-0AA0 3VA5170-6EC31-0AA0 3VA5180-6EC31-0AA0 3VA5190-6EC31-0AA0 3VA5110-6EC31-0AA0 3VA5111-6EC31-0AA0 3VA5112-6EC31-0AA0 3VA5195-6EF31-0AA0 3VA5120-6EF31-0AA0 3VA5130-6EF31-0AA0 3VA5140-6EF31-0AA0 3VA5150-6EF31-0AA0 3VA5160-6EF31-0AA0 3VA5170-6EF31-0AA0 3VA5180-6EF31-0AA0 3VA5110-6EF31-0AA0 Dimensions Breaker 3VA51 3VA51 3VA51 3VA51 Poles 1 2 3 4 W in. (mm) 1 (25.4) 2 (50.8) 3 (76.2) 4 (101.6) H in. (mm) 5.5 (140) 5.5 (140) 5.5 (140) 5.5 (140) D in. (mm) 3 (76.5) 3 (76.5) 3 (76.5) 3 (76.5) Shipping Weight lbs. kg 0.84 0.38 1.37 0.62 1.73 0.78 2.09 0.95 3VA51 125A 3-Pole Enclosures (3-pole only) Nema Type 1 surface 1 flush 3R 12 4X (304) 4X (316) Neutral Catalog Number 3VAE125N1S 3VAE125N1F 3VAE125N3R 3VAE125N12 3VAE125N4X 3VAE125N4X316 N125X MOLDED CASE 7 CIRCUIT BREAKERS a Available with NAVAL/50C ratings. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-51 MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers 3VA51 125A Thermal-magnetic Trip Circuit Breakers 3VA51 125A Frame, 4-Pole Thermal-Magnetic Trip Unit Cont. Ampere Rating 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 S-Interrupting Class (SEAS) Catalog Number 3VA5195-4ED41-0AA0 3VA5120-4ED41-0AA0 3VA5125-4ED41-0AA0 3VA5130-4ED41-0AA0 3VA5135-4ED41-0AA0 3VA5140-4ED41-0AA0 3VA5145-4ED41-0AA0 3VA5150-4ED41-0AA0 3VA5160-4ED41-0AA0 3VA5170-4ED41-0AA0 3VA5180-4ED41-0AA0 3VA5190-4ED41-0AA0 3VA5110-4ED41-0AA0 3VA5111-4ED41-0AA0 3VA5112-4ED41-0AA0 M-Interrupting Class (MEAS) H-Interrupting Class (HEAS) Catalog Number Catalog Number TM210 FTFM Unprotected Neutral 3VA5195-5ED41-0AA0 3VA5120-5ED41-0AA0 3VA5125-5ED41-0AA0 3VA5130-5ED41-0AA0 3VA5135-5ED41-0AA0 3VA5140-5ED41-0AA0 3VA5145-5ED41-0AA0 3VA5150-5ED41-0AA0 3VA5160-5ED41-0AA0 3VA5170-5ED41-0AA0 3VA5180-5ED41-0AA0 3VA5190-5ED41-0AA0 3VA5110-5ED41-0AA0 3VA5111-5ED41-0AA0 3VA5112-5ED41-0AA0 3VA5195-6ED41-0AA0 3VA5120-6ED41-0AA0 3VA5125-6ED41-0AA0 3VA5130-6ED41-0AA0 3VA5135-6ED41-0AA0 3VA5140-6ED41-0AA0 3VA5145-6ED41-0AA0 3VA5150-6ED41-0AA0 3VA5160-6ED41-0AA0 3VA5170-6ED41-0AA0 3VA5180-6ED41-0AA0 3VA5190-6ED41-0AA0 3VA5110-6ED41-0AA0 3VA5111-6ED41-0AA0 3VA5112-6ED41-0AA0 TM210 FTFM 100% Neutral 90 3VA5190-4GD41-0AA0 3VA5190-5GD41-0AA0 3VA5190-6GD41-0AA0 100 3VA5110-4GD41-0AA0 3VA5110-5GD41-0AA0 3VA5110-6GD41-0AA0 110 3VA5111-4GD41-0AA0 3VA5111-5GD41-0AA0 3VA5111-6GD41-0AA0 125 3VA5112-4GD41-0AA0 3VA5112-5GD41-0AA0 3VA5112-6GD41-0AA0 TM230 FTAM Unprotected Neutral 15 3VA5195-4EC41-0AA0 3VA5195-5EC41-0AA0 3VA5195-6EC41-0AA0 20 3VA5120-4EC41-0AA0 3VA5120-5EC41-0AA0 3VA5120-6EC41-0AA0 25 3VA5125-4EC41-0AA0 3VA5125-5EC41-0AA0 3VA5125-6EC41-0AA0 30 3VA5130-4EC41-0AA0 3VA5130-5EC41-0AA0 3VA5130-6EC41-0AA0 35 3VA5135-4EC41-0AA0 3VA5135-5EC41-0AA0 3VA5135-6EC41-0AA0 40 3VA5140-4EC41-0AA0 3VA5140-5EC41-0AA0 3VA5140-6EC41-0AA0 45 3VA5145-4EC41-0AA0 3VA5145-5EC41-0AA0 3VA5145-6EC41-0AA0 50 3VA5150-4EC41-0AA0 3VA5150-5EC41-0AA0 3VA5150-6EC41-0AA0 60 3VA5160-4EC41-0AA0 3VA5160-5EC41-0AA0 3VA5160-6EC41-0AA0 70 3VA5170-4EC41-0AA0 3VA5170-5EC41-0AA0 3VA5170-6EC41-0AA0 80 3VA5180-4EC41-0AA0 3VA5180-5EC41-0AA0 3VA5180-6EC41-0AA0 90 3VA5190-4EC41-0AA0 3VA5190-5EC41-0AA0 3VA5190-6EC41-0AA0 100 3VA5110-4EC41-0AA0 3VA5110-5EC41-0AA0 3VA5110-6EC41-0AA0 110 3VA5111-4EC41-0AA0 3VA5111-5EC41-0AA0 3VA5111-6EC41-0AA0 125 3VA5112-4EC41-0AA0 3VA5112-5EC41-0AA0 3VA5112-6EC41-0AA0 TM230 FTFM 100% Neutral 90 3VA5190-4GC41-0AA0 3VA5190-5GC41-0AA0 3VA5190-6GC41-0AA0 100 3VA5110-4GC41-0AA0 3VA5110-5GC41-0AA0 3VA5110-6GC41-0AA0 110 3VA5111-4GC41-0AA0 3VA5111-5GC41-0AA0 3VA5111-6GC41-0AA0 125 3VA5112-4GC41-0AA0 3VA5112-5GC41-0AA0 3VA5112-6GC41-0AA0 TM240 ATAM Unprotected Neutral 15 3VA5195-4EF41-0AA0 3VA5195-5EF41-0AA0 3VA5195-6EF41-0AA0 20 3VA5120-4EF41-0AA0 3VA5120-5EF41-0AA0 3VA5120-6EF41-0AA0 30 3VA5130-4EF41-0AA0 3VA5130-5EF41-0AA0 3VA5130-6EF41-0AA0 40 3VA5140-4EF41-0AA0 3VA5140-5EF41-0AA0 3VA5140-6EF41-0AA0 50 3VA5150-4EF41-0AA0 3VA5150-5EF41-0AA0 3VA5150-6EF41-0AA0 60 3VA5160-4EF41-0AA0 3VA5160-5EF41-0AA0 3VA5160-6EF41-0AA0 70 3VA5170-4EF41-0AA0 3VA5170-5EF41-0AA0 3VA5170-6EF41-0AA0 80 3VA5180-4EF41-0AA0 3VA5180-5EF41-0AA0 3VA5180-6EF41-0AA0 100 3VA5110-4EF41-0AA0 3VA5110-5EF41-0AA0 3VA5110-6EF41-0AA0 TM240 ATAM 100% Neutral 100 3VA5110-4GF41-0AA0 3VA5110-5GF41-0AA0 3VA5110-6GF41-0AA0 7-52 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Revised on 04/30/21 Selection 3VA51 125A 4-Pole 3VA Molded Case Circuit Breakers 3VA51 125A Thermal-magnetic Trip Circuit Breakers Revised on 06/30/21 Technical information Trip Settings for 3VA51 TM210 - FTFM In (A) 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 Ir (A) 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 Ii (A) 300 300 300 300 350 400 450 500 600 700 800 900 1000 1100 1250 TM230 - FTAM TM240 - ATAM In (A) Ir (A) Ii (A) Ir (A) Ir (A) In (A) 90% 80% Ii (A) 15 15 150 180 210 240 270 300 15 14 12 150 180 210 240 270 300 20 20 150 180 210 240 270 300 20 18 16 150 180 210 240 270 300 25 25 150 180 210 240 270 300 30 30 150 180 210 240 270 300 35 35 175 210 245 280 315 350 40 40 200 240 280 320 360 400 30 27 24 150 180 210 240 270 300 40 36 32 200 240 280 320 360 400 50 45 40 250 300 350 400 450 500 60 54 48 300 360 420 480 540 600 45 45 225 270 315 360 405 450 70 63 56 350 420 490 560 630 700 50 50 250 300 350 400 450 500 80 72 64 400 480 560 640 720 800 60 60 300 360 420 480 540 600 100 90 80 500 600 700 800 900 1000 70 70 350 420 490 560 630 700 80 90 80 90 400 450 480 540 560 630 640 720 720 810 8900003VA UL Molded Case Circuit Breakers 100 100 500 600 700 800 900 1000Accessories and Spare Parts 110 110 550 660 770 880 990 1100Internal accessories 125 125 625 750 875 1000 1125 1250 Design Connectors for 75C Wire for 3VA51 Type Steel wrap around (Cu cable only), 1 cable lugs Aluminum body lug small (Cu/Al cable), 1 cable lugac Aluminum body lug (Cu/Al cable), 1 cable lugsbc Aluminum body lug small with control wire tap (Cu/Al cable), 1 cable luga Aluminum body lug with control wire tap (Cu/Al cable), 1 cable lugsb Aluminum body lug large (Cu/ Al cable), 1 cable lugs with 1 extended terminal cover Aluminum body lug large with control wire tap (Cu/Al cable), 1 cable lug and 1 extended terminal cover Distribution lug, 6 cables (Cu/ Al cable), 1 cable lugs with 1 extended terminal cover Copper body lug small (Cu cable only), 1 cable lugsa Copper body lug (Cu cable only), 1 cable lugsb Copper body lug small with control wire tap (Cu cable only), 1 cable lugsa Copper body lug with control wire tap (Cu cable only), 1 cable lugsb Min. cable size AWG 14 AWG 14 AWG 8 AWG 14 AWG 8 AWG 4 AWG 4 AWG 14 AWG 14 AWG 8 AWG 14 AWG 8 Max. cable size 3/0 AWG 8 3/0 AWG 8 3/0 300 kcmil 300 kcmil AWG 2 AWG 8 2/0 AWG 8 2/0 Catalog No. (kit of 3 lugs) Catalog No. (kit of 4 lugs) 3VA9133-0JA11 3VA9134-0JA11 3VA9133-0JB10 3VA9134-0JB10 3VA9133-0JB11 3VA9134-0JB11 3VA9133-0JG10 3VA9134-0JG10 3VA9133-0JG11 3VA9134-0JG11 3VA9133-0JJ12 3VA9134-0JJ12 3VA9133-0JC12 3VA9133-0JF60 3VA9134-0JF60 4 3VA9133-0JD10 3VA9134-0JD10 3VA9133-0JD11 3VA9134-0JD11 3VA9133-0JK10 3VA9134-0JK10 3VA9133-0JK11 3VA9134-0JK11 Internal accessories configuration 3VA4/3VA5 125 A 1 in 2-pole /2-pole 3VA5 125 A 3 & 4-pole Auxiliary switch Auxiliary switch Leading changeover switch Alarm switch Trip alarm switch Short circuit alarm switch Auxiliary release Shunt trip flexible Shunt trip left Residual current release Undervoltage release Universal release Other Cylinder lock (type Ronis) Slot No.: Type AUX_HQ AUX_HQ_el AUX_HP LCS_HQ LCS_HQ_el LCS_HP Type TAS_HQ TAS_HQ_el TAS_HP SAS_HQ SAS_HQ_el Type STF STL STL_el RCR UVR UNI 125 A 23 22 21 xxx xxx x x xx xx x x x x x 125 A 23 22 21 11 12 13 xxx xxx x x xxx xxx x x x x x xx xx x xx xx x x x x x x MOLDED CASE 7 CIRCUIT BREAKERS a Use these lugs on 15A to 40A breakers. b Use these lugs on 45A to 125A breakers. c Standard lug installed at the factory when breaker ordered with a "6" in the 12th position. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-53 3VA Molded Case Circuit Breakers Revised on 10/31/21 3VA61 150A Electronic Trip Circuit Breakers Selection 3VA61 150A 3-Pole Ordering Information The numbers listed here are for complete, non-interchangeable trip circuit breakers without lugs. For factory installed nut keepers (3VA92430QA00), change the 12th digit of the catalog number to "2" (required to install a breaker in a panelboard or switchboard that has a provision). (For example, a 35KA @480VAC, 40A, 3-pole, 3VA61 with nut keepers is catalog number 3VA6140-5HL32-0AA0). For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 40A, 3-pole, 3VA61 with lugs is catalog number 3VA6140-5HL36-0AA0). Alternate connectors can be ordered separately for field installation. All 3VA61 electronic trip circuit breakers are available with 100% ratings. To order, change the 13th digit of the catalog number to the number "2". (For example, a 35KA @480VAC, 40A, 3-pole, 100% rated 3VA61 is catalog number 3VA6140-5HL31-2AA0). Requires the use of rated lugs -- see lug table below. All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked "Naval", and are suitable for use at 50C. They are UL listed for reverse feed applications. 3VA61 150A Frame 3-Pole Electronic Trip Unit Continuous Ampere M-Interrupting Class (MDAE) Catalog Number H-Interrupting Class (HDAE) Catalog Number C-Interrupting Class (CDAE) Catalog Number L-Interrupting Class (LDAE) Catalog Number ETU320 LI with dials 40 3VA6140-5HL31-0AA0 3VA6140-6HL31-0AA0 3VA6140-7HL31-0AA0 3VA6140-8HL31-0AA0 60 -- -- -- -- 100 3VA6110-5HL31-0AA0 3VA6110-6HL31-0AA0 3VA6110-7HL31-0AA0 3VA6110-8HL31-0AA0 150 3VA6115-5HL31-0AA0 3VA6115-6HL31-0AA0 3VA6115-7HL31-0AA0 3VA6115-8HL31-0AA0 ETU330 LIG with dials 40 3VA6140-5HM31-0AA0 3VA6140-6HM31-0AA0 3VA6140-7HM31-0AA0 3VA6140-8HM31-0AA0 60 -- -- -- -- 100 3VA6110-5HM31-0AA0 3VA6110-6HM31-0AA0 3VA6110-7HM31-0AA0 3VA6110-8HM31-0AA0 150 3VA6115-5HM31-0AA0 3VA6115-6HM31-0AA0 3VA6115-7HM31-0AA0 3VA6115-8HM31-0AA0 ETU350 LSI with dials 40 3VA6140-5HN31-0AA0 3VA6140-6HN31-0AA0 3VA6140-7HN31-0AA0 3VA6140-8HN31-0AA0 60 -- -- -- -- 100 3VA6110-5HN31-0AA0 3VA6110-6HN31-0AA0 3VA6110-7HN31-0AA0 3VA6110-8HN31-0AA0 150 3VA6115-5HN31-0AA0 3VA6115-6HN31-0AA0 3VA6115-7HN31-0AA0 3VA6115-8HN31-0AA0 ETU550 LSI with LCD 40 3VA6140-5JP31-0AA0 3VA6140-6JP31-0AA0 3VA6140-7JP31-0AA0 3VA6140-8JP31-0AA0 100 3VA6110-5JP31-0AA0 3VA6110-6JP31-0AA0 3VA6110-7JP31-0AA0 3VA6110-8JP31-0AA0 150 3VA6115-5JP31-0AA0 3VA6115-6JP31-0AA0 3VA6115-7JP31-0AA0 3VA6115-8JP31-0AA0 ETU556 LSI(G Alarm) with LCD 40 3VA6140-5JT31-0AA0 3VA6140-6JT31-0AA0 3VA6140-7JT31-0AA0 3VA6140-8JT31-0AA0 100 3VA6110-5JT31-0AA0 3VA6110-6JT31-0AA0 3VA6110-7JT31-0AA0 3VA6110-8JT31-0AA0 150 3VA6115-5JT31-0AA0 3VA6115-6JT31-0AA0 3VA6115-7JT31-0AA0 3VA6115-8JT31-0AA0 ETU560 LSIG with LCD 40 3VA6140-5JQ31-0AA0 3VA6140-6JQ31-0AA0 3VA6140-7JQ31-0AA0 3VA6140-8JQ31-0AA0 100 3VA6110-5JQ31-0AA0 3VA6110-6JQ31-0AA0 3VA6110-7JQ31-0AA0 3VA6110-8JQ31-0AA0 150 3VA6115-5JQ31-0AA0 3VA6115-6JQ31-0AA0 3VA6115-7JQ31-0AA0 3VA6115-8JQ31-0AA0 ETU820 LI LCD with Metering 40 3VA6140-5KL31-0AA0 3VA6140-6KL31-0AA0 3VA6140-7KL31-0AA0 3VA6140-8KL31-0AA0 100 3VA6110-5KL31-0AA0 3VA6110-6KL31-0AA0 3VA6110-7KL31-0AA0 3VA6110-8KL31-0AA0 150 3VA6115-5KL31-0AA0 3VA6115-6KL31-0AA0 3VA6115-7KL31-0AA0 3VA6115-8KL31-0AA0 ETU830 LIG with LCD and Metering 40 3VA6140-5KM31-0AA0 3VA6140-6KM31-0AA0 3VA6140-7KM31-0AA0 3VA6140-8KM31-0AA0 100 3VA6110-5KM31-0AA0 3VA6110-6KM31-0AA0 3VA6110-7KM31-0AA0 3VA6110-8KM31-0AA0 150 3VA6115-5KM31-0AA0 3VA6115-6KM31-0AA0 3VA6115-7KM31-0AA0 3VA6115-8KM31-0AA0 ETU850 LSI with LCD and Metering 40 3VA6140-5KP31-0AA0 3VA6140-6KP31-0AA0 3VA6140-7KP31-0AA0 3VA6140-8KP31-0AA0 100 3VA6110-5KP31-0AA0 3VA6110-6KP31-0AA0 3VA6110-7KP31-0AA0 3VA6110-8KP31-0AA0 150 3VA6115-5KP31-0AA0 3VA6115-6KP31-0AA0 3VA6115-7KP31-0AA0 3VA6115-8KP31-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 40 3VA6140-5KT31-0AA0 3VA6140-6KT31-0AA0 3VA6140-7KT31-0AA0 3VA6140-8KT31-0AA0 60 -- -- -- -- 100 3VA6110-5KT31-0AA0 3VA6110-6KT31-0AA0 3VA6110-7KT31-0AA0 3VA6110-8KT31-0AA0 150 3VA6115-5KT31-0AA0 3VA6115-6KT31-0AA0 3VA6115-7KT31-0AA0 3VA6115-8KT31-0AA0 ETU860 LSIG with LCD and Metering 40 3VA6140-5KQ31-0AA0 3VA6140-6KQ31-0AA0 3VA6140-7KQ31-0AA0 3VA6140-8KQ31-0AA0 60 -- -- -- -- 100 3VA6110-5KQ31-0AA0 3VA6110-6KQ31-0AA0 3VA6110-7KQ31-0AA0 3VA6110-8KQ31-0AA0 150 3VA6115-5KQ31-0AA0 3VA6115-6KQ31-0AA0 3VA6115-7KQ31-0AA0 3VA6115-8KQ31-0AA0 E-Interrupting Class (EDAE) Catalog Number -- 3VA6160-0HL31-0AA0 3VA6110-0HL31-0AA0 3VA6115-0HL31-0AA0 -- 3VA6160-0HM31-0AA0 3VA6110-0HM31-0AA0 3VA6115-0HM31-0AA0 -- 3VA6160-0HN31-0AA0 3VA6110-0HN31-0AA0 3VA6115-0HN31-0AA0 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3VA6160-0KT31-0AA0 3VA6110-0KT31-0AA0 3VA6115-0KT31-0AA0 -- 3VA6160-0KQ31-0AA0 3VA6110-0KQ31-0AA0 3VA6115-0KQ31-0AA0 MOLDED CASE 7 CIRCUIT BREAKERS 7-54 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA61 150A Electronic Trip Circuit Breakers Revised on 10/31/21 Selection MOLDED CASE 7 CIRCUIT BREAKERS 3VA61 150A 4-Pole 3VA61 150A Frame 4-Pole Electronic Trip Unit Continuous Ampere M-Interrupting Class (MDAE) Catalog Number 40 3VA6140-5HL41-0AA0 60 -- 100 3VA6110-5HL41-0AA0 150 3VA6115-5HL41-0AA0 40 3VA6140-5HM41-0AA0 60 -- 100 3VA6110-5HM41-0AA0 150 3VA6115-5HM41-0AA0 40 3VA6140-5HN41-0AA0 60 -- 100 3VA6110-5HN41-0AA0 150 3VA6115-5HN41-0AA0 40 3VA6140-5JP41-0AA0 100 3VA6110-5JP41-0AA0 150 3VA6115-5JP41-0AA0 40 3VA6140-5JT41-0AA0 100 3VA6110-5JT41-0AA0 150 3VA6115-5JT41-0AA0 40 3VA6140-5JQ41-0AA0 100 3VA6110-5JQ41-0AA0 150 3VA6115-5JQ41-0AA0 40 3VA6140-5KL41-0AA0 100 3VA6110-5KL41-0AA0 150 3VA6115-5KL41-0AA0 H-Interrupting Class (HDAE) Catalog Number 3VA6140-6HL41-0AA0 -- 3VA6110-6HL41-0AA0 3VA6115-6HL41-0AA0 3VA6140-6HM41-0AA0 -- 3VA6110-6HM41-0AA0 3VA6115-6HM41-0AA0 3VA6140-6HN41-0AA0 -- 3VA6110-6HN41-0AA0 3VA6115-6HN41-0AA0 3VA6140-6JP41-0AA0 3VA6110-6JP41-0AA0 3VA6115-6JP41-0AA0 3VA6140-6JT41-0AA0 3VA6110-6JT41-0AA0 3VA6115-6JT41-0AA0 3VA6140-6JQ41-0AA0 3VA6110-6JQ41-0AA0 3VA6115-6JQ41-0AA0 3VA6140-6KL41-0AA0 3VA6110-6KL41-0AA0 3VA6115-6KL41-0AA0 C-Interrupting Class (CDAE) L-Interrupting Class (LDAE) Catalog Number Catalog Number ETU320 LI with dials 3VA6140-7HL41-0AA0 3VA6140-8HL41-0AA0 -- -- 3VA6110-7HL41-0AA0 3VA6110-8HL41-0AA0 3VA6115-7HL41-0AA0 3VA6115-8HL41-0AA0 ETU330 LIG with dials 3VA6140-7HM41-0AA0 3VA6140-8HM41-0AA0 -- -- 3VA6110-7HM41-0AA0 3VA6110-8HM41-0AA0 3VA6115-7HM41-0AA0 3VA6115-8HM41-0AA0 ETU350 LSI with dials 3VA6140-7HN41-0AA0 3VA6140-8HN41-0AA0 -- 3VA6110-7HN41-0AA0 3VA6115-7HN41-0AA0 -- 3VA6110-8HN41-0AA0 3VA6115-8HN41-0AA0 ETU550 LSI with LCD 3VA6140-7JP41-0AA0 3VA6140-8JP41-0AA0 3VA6110-7JP41-0AA0 3VA6110-8JP41-0AA0 3VA6115-7JP41-0AA0 3VA6115-8JP41-0AA0 ETU556 LSI(G Alarm) with LCD 3VA6140-7JT41-0AA0 3VA6140-8JT41-0AA0 3VA6110-7JT41-0AA0 3VA6110-8JT41-0AA0 3VA6115-7JT41-0AA0 3VA6115-8JT41-0AA0 ETU560 LSIG with LCD 3VA6140-7JQ41-0AA0 3VA6140-8JQ41-0AA0 3VA6110-7JQ41-0AA0 3VA6110-8JQ41-0AA0 3VA6115-7JQ41-0AA0 3VA6115-8JQ41-0AA0 ETU820 LI LCD with Metering 3VA6140-7KL41-0AA0 3VA6140-8KL41-0AA0 3VA6110-7KL41-0AA0 3VA6110-8KL41-0AA0 3VA6115-7KL41-0AA0 3VA6115-8KL41-0AA0 ETU830 LIG with LCD and Metering 40 3VA6140-5KM41-0AA0 3VA6140-6KM41-0AA0 3VA6140-7KM41-0AA0 3VA6140-8KM41-0AA0 100 3VA6110-5KM41-0AA0 3VA6110-6KM41-0AA0 3VA6110-7KM41-0AA0 3VA6110-8KM41-0AA0 150 3VA6115-5KM41-0AA0 3VA6115-6KM41-0AA0 3VA6115-7KM41-0AA0 3VA6115-8KM41-0AA0 ETU850 LSI with LCD and Metering 40 3VA6140-5KP41-0AA0 3VA6140-6KP41-0AA0 3VA6140-7KP41-0AA0 3VA6140-8KP41-0AA0 100 3VA6110-5KP41-0AA0 3VA6110-6KP41-0AA0 3VA6110-7KP41-0AA0 3VA6110-8KP41-0AA0 150 3VA6115-5KP41-0AA0 3VA6115-6KP41-0AA0 3VA6115-7KP41-0AA0 3VA6115-8KP41-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 40 3VA6140-5KT41-0AA0 3VA6140-6KT41-0AA0 3VA6140-7KT41-0AA0 3VA6140-8KT41-0AA0 60 -- -- -- -- 100 3VA6110-5KT41-0AA0 3VA6110-6KT41-0AA0 3VA6110-7KT41-0AA0 3VA6110-8KT41-0AA0 150 3VA6115-5KT41-0AA0 3VA6115-6KT41-0AA0 3VA6115-7KT41-0AA0 3VA6115-8KT41-0AA0 ETU860 LSIG with LCD and Metering 40 3VA6140-5KQ41-0AA0 3VA6140-6KQ41-0AA0 3VA6140-7KQ41-0AA0 3VA6140-8KQ41-0AA0 60 -- -- -- -- 100 3VA6110-5KQ41-0AA0 3VA6110-6KQ41-0AA0 3VA6110-7KQ41-0AA0 3VA6110-8KQ41-0AA0 150 3VA6115-5KQ41-0AA0 3VA6115-6KQ41-0AA0 3VA6115-7KQ41-0AA0 3VA6115-8KQ41-0AA0 E-Interrupting Class (EDAE) Catalog Number -- 3VA6160-0HL41-0AA0 3VA6110-0HL41-0AA0 3VA6115-0HL41-0AA0 -- 3VA6160-0HM41-0AA0 3VA6110-0HM41-0AA0 3VA6115-0HM41-0AA0 -- 3VA6160-0HN41-0AA0 3VA6110-0HN41-0AA0 3VA6115-0HN41-0AA0 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3VA6160-0KT41-0AA0 3VA6110-0KT41-0AA0 3VA6115-0KT41-0AA0 -- 3VA6160-0KQ41-0AA0 3VA6110-0KQ41-0AA0 3VA6115-0KQ41-0AA0 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-55 3VA Molded Case Circuit Breakers 3VA61 150A Electronic Trip Circuit Breakers Revised on 04/30/21 Technical information Connectors for 75C wire for 3VA61 Type Steel Wrap around (Cu cable only) single cable lugsb Aluminum Body Lug (Cu/Al cable) single cable lugsa Aluminum body lug with control wire tap (Cu/Al cable) single cable lugsa Aluminum body lug large (Cu/Al cable) single cable lugs and 1 ext'd terminal covera Aluminum body lug large with control wire tap (Cu/Al cable) single cable lugs and 1 extended terminal covera Aluminum body lug, 2 cables (Cu/Al cable) with 1 extended terminal covera Aluminum body lug, 2 cables (Cu/Al cable) with control wire tap and 1 extended terminal covera Distribution lug, 6 Cables (Cu/Al cable) with 1 extended terminal coverb Copper body lug (Cu cable only) single cable lugs kit of 3 single lugsa Copper body lug (Cu cable only) with control wire tap single cable lugsa Minimum cable size AWG 10 AWG 4 AWG 14 AWG 6 AWG 14 AWG 6 AWG 2 AWG 2 AWG 4 AWG 4 AWG 14 AWG 14 AWG 6 AWG 14 AWG 6 Maximum cable size 3/0 350 kcmil 1/0 350 kcmil 1/0 350 kcmil 350 kcmil 350 kcmil 300 kcmil 300 kcmil AWG 2 1/0 350 kcmil 1/0 350 kcmil Part Number (kit of 3 lugs) 3VA9143-0JA12 3VA9243-0JA12 3VA9143-0JB11 3VA9243-0JB12d 3VA9143-0JG11c 3VA9243-0JG12 3VA9243-0JJ13 3VA9243-0JC13 3VA9243-0JJ22 3VA9243-0JC22 3VA9243-0JF60 3VA9143-0JD11 3VA9243-0JD12 3VA9143-0JK11c 3VA9243-0JK12 Part Number (kit of 4 lugs) 3VA9144-0JA12 3VA9244-0JA12 3VA9144-0JB11 3VA9244-0JB12d 3VA9144-0JG11c 3VA9244-0JG12 3VA9244-0JJ13 3VA9244-0JC13 3VA9244-0JJ22 3VA9244-0JC22 3VA9244-0JF60 3VA9144-0JD11 3VA9244-0JD12 3VA9144-0JK11c 3VA9244-0JK12 Interrupting Ratings for 3VA61 Interrupting Class M H C L E Breaker Type MDAE HDAE CDAE LDAE EDAE RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240 480Y/277V 480 100 35 35 100 65 65 200 100 100 200 150 150 -- 200 200 600Y/347V 18 22 35 50 100 600 18 22 35 50 100 Dimensions Breaker 3VA61 3VA61 Poles 3 4 W in. (mm) 4.1 (105) 5.5 (140) H in. (mm) 7.8 (198) 7.8 (198) D in. (mm) 3.4 (86) 3.4 (86) Shipping Weight lbs. kg 5.5 2.5 7.1 3.2 Enclosures (3-pole only) Nema Type 1 surface 1 flush 3R 12 4X (304) 4X (316) Neutral 200% Neutral Catalog Number 3VAE250N1S 3VAE250N1F 3VAE250N3R 3VAE250N12 3VAE250N4X 3VAE250N4X316 N250X N2250X MOLDED CASE 7 CIRCUIT BREAKERS a Meets requirements for 100% rated breakers up to 150A. b Meets requirements for 100% rated breakers up to 100A. c Limited to 150A including the control wire tap. d Standard lug installed at the factory when breaker ordered with a "6" in the 12th position. 7-56 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA61 150A Electronic Trip Circuit Breakers Revised on 01/31/21 Technical information Trip Settings for 3VA61 ETU320-LI, ETU330-LIG, ETU350-LSI Continuous Amperage LI, LIG, LSI In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I)a 40 15 - 40 0.5 - 17 60-480 100 40 - 100 0.5 - 17 150-1200 150 60 - 150 0.5 - 17 225-1500 a Ii for ETU350 is fixed at the maximum level shown in table. LSI Isd= xIr (Amp) (S) 1.5 - 10 1.5 - 10 1.5 - 10 LI, LIG, LSI LIG 4P only tsd (sec) (S) 0.08 - 0.4 Ig (Amp) (G) 15 - 40 20 - 100 30 - 150 IN=xIr (Amp) 1 / OFF 0.5 - 1 / OFF 0.5 - 1 / OFF ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG Continuous Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G) LSI 3P with External CT LI, LIG, LSI, LSIG, LSI(G) 4P only In (Amp) Ir(Amp) (L)b tld (sec) (L) Ii (Amp) (I) Isd (Amp) (S) tsd (sec) (S) Ig (Amp) (G) tg (G) IN=xIr (Amp) IN (Amp) 40 15 - 40 0.5 - 25 60-480 24 - 400 0.05 - 0.5 15 - 40 0.05 - 0.8 15 - 64 / OFF 15 - 64 / OFF 100 40 - 100 0.5 - 25 150-1200 60 - 1000 20 - 100 20 - 160 / OFF 20 - 150 / OFF 150 60 - 150 0.5 - 20 225-1500 90 - 1500 30 - 150 30 - 240 / OFF 30 - 150 / OFF b Adjustable in steps of 1A. 3VA UL Molded Case Circuit Breakers For specific trip settings refer to the Electronic Trip Unit section of the 3VAAScycsetesmsosriMesanaunadl,Spare Parts which can be found in the document download center at https://digitalcontentcenter.compas.siemens-info.com/SIE_IM_3VA6_Systems_Manual.pdf Internal accessories Internal accessories Optional equipment 3VA6 150/250 A 3-pole 3VA6 150/250 A 4-pole Auxiliary switch Auxiliary switch Leading changeover switch Alarm switch Trip alarm switch Electrical alarm switch Auxiliary release Shunt trip flexible Slot No.: Type AUX_HQ AUX_HQ_el AUX_HP LCS_HQ LCS_HQ_el LCS_HP Type TAS_HQ TAS_HQ_el TAS_HP EAS_HQ EAS_HQ_el Type 250 A 250 A 24 23 22 21 11 12 13 14 34 33 32 31 24 23 22 21 11 12 13 14 xxxx xxxx x x x xxxx xxxx xx x x x x xxxx xxxx x x x xxxx xxxx x x x xxxx xxxx xx x x x x xx xx xx xx x x x x xx xx xx xx x x x x STF x x x x Shunt trip left Undervoltage release Universal release ETU/communication Communication module Breaker data server 24 V module Other Cylinder lock (type Ronis) STL x UVR x UNI x Type COM060 x x x See page 7-83 for internal accessory part numbers. x 4 x x x x x I201_19495 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-57 3VA Molded Case Circuit Breakers 3VA52 250A Thermal-magnetic Trip Circuit Breakers Revised on 04/30/21 Selection 3VA52 250 A, 2-Pole in 3-Pole Frame Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MFAS) Catalog Number H-Interrupting Class (HFAS) Catalog Number C-Interrupting Class (CFAS) Catalog Number TM210 FTFM 40 3VA5240-5ED61-0AA0 3VA5240-6ED61-0AA0 3VA5240-7ED61-0AA0 45 3VA5245-5ED61-0AA0 3VA5245-6ED61-0AA0 3VA5245-7ED61-0AA0 50 3VA5250-5ED61-0AA0 3VA5250-6ED61-0AA0 3VA5250-7ED61-0AA0 60 3VA5260-5ED61-0AA0 3VA5260-6ED61-0AA0 3VA5260-7ED61-0AA0 70 3VA5270-5ED61-0AA0 3VA5270-6ED61-0AA0 3VA5270-7ED61-0AA0 80 3VA5280-5ED61-0AA0 3VA5280-6ED61-0AA0 3VA5280-7ED61-0AA0 90 3VA5290-5ED61-0AA0 3VA5290-6ED61-0AA0 3VA5290-7ED61-0AA0 100 3VA5210-5ED61-0AA0 3VA5210-6ED61-0AA0 3VA5210-7ED61-0AA0 110 3VA5211-5ED61-0AA0 3VA5211-6ED61-0AA0 3VA5211-7ED61-0AA0 125 3VA5212-5ED61-0AA0 3VA5212-6ED61-0AA0 3VA5212-7ED61-0AA0 150 3VA5215-5ED61-0AA0 3VA5215-6ED61-0AA0 3VA5215-7ED61-0AA0 175 3VA5217-5ED61-0AA0 3VA5217-6ED61-0AA0 3VA5217-7ED61-0AA0 200 3VA5220-5ED61-0AA0 3VA5220-6ED61-0AA0 3VA5220-7ED61-0AA0 225 3VA5222-5ED61-0AA0 3VA5222-6ED61-0AA0 3VA5222-7ED61-0AA0 250 3VA5225-5ED61-0AA0 3VA5225-6ED61-0AA0 3VA5225-7ED61-0AA0 TM230 FTAM 70 3VA5270-5EC61-0AA0 3VA5270-6EC61-0AA0 3VA5270-7EC61-0AA0 80 3VA5280-5EC61-0AA0 3VA5280-6EC61-0AA0 3VA5280-7EC61-0AA0 90 3VA5290-5EC61-0AA0 3VA5290-6EC61-0AA0 3VA5290-7EC61-0AA0 100 3VA5210-5EC61-0AA0 3VA5210-6EC61-0AA0 3VA5210-7EC61-0AA0 110 3VA5211-5EC61-0AA0 3VA5211-6EC61-0AA0 3VA5211-7EC61-0AA0 125 3VA5212-5EC61-0AA0 3VA5212-6EC61-0AA0 3VA5212-7EC61-0AA0 150 3VA5215-5EC61-0AA0 3VA5215-6EC61-0AA0 3VA5215-7EC61-0AA0 175 3VA5217-5EC61-0AA0 3VA5217-6EC61-0AA0 3VA5217-7EC61-0AA0 200 3VA5220-5EC61-0AA0 3VA5220-6EC61-0AA0 3VA5220-7EC61-0AA0 225 3VA5222-5EC61-0AA0 3VA5222-6EC61-0AA0 3VA5222-7EC61-0AA0 250 3VA5225-5EC61-0AA0 3VA5225-6EC61-0AA0 3VA5225-7EC61-0AA0 Dimensions Breaker 3VA52 3VA52 Poles 2(3-) pole 3-pole W in. (mm) 4.1 (105) 4.1 (105) H in. (mm) 7.3 (185) 7.3 (185) D in. (mm) 3.3 (83) 3.3 (83) Shipping Weight lbs. kg 4.1 1.9 4.5 2.1 Enclosures (3-pole only) Nema Type 1 surface 1 flush 3R 12 4X (304) 4X (316) Neutral 200% Neutral Catalog Number 3VAE250N1S 3VAE250N1F 3VAE250N3R 3VAE250N12 3VAE250N4X 3VAE250N4X316 N250X N2250X 3VA52 250A 3-Pole Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers without lugs. For factory installed nut keepers (3VA92330QA00), change the 12th digit of the catalog number to "2" (required to install a breaker in a panelboard or switchboard that has a provision). (For example, a 35KA @480VAC, 150A, 3-pole, 3VA52 with nut keepers would be catalog number 3VA5215-5ED32-0AA0). For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 150A, 3-pole, 3VA52 with lugs would be catalog number 3VA5215-5ED36-0AA0). Alternate connectors can be ordered separately for field installation. For NAVAL-rated thermal-magnetic trip circuit breakers, change the 13th digit of the catalog number to the number "1". (For example, a 35KA @480VAC, 150A, 3-pole, NAVAL rated 3VA52 would be catalog number 3VA5215-5ED31-1AA0) All 3VA52 thermal-magnetic trip circuit breakers are UL listed for reverse feed applications. MOLDED CASE 7 CIRCUIT BREAKERS 7-58 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA52 250A Thermal-magnetic Trip Circuit Breakers Revised on 04/30/21 Selection 3VA52 250 A Frame, 3-Pole Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MFAS) Catalog Number H-Interrupting Class (HFAS) Catalog Number TM210 FTFMa C-Interrupting Class (CFAS) Catalog Number 40 3VA5240-5ED31-0AA0 3VA5240-6ED31-0AA0 3VA5240-7ED31-0AA0 45 3VA5245-5ED31-0AA0 3VA5245-6ED31-0AA0 3VA5245-7ED31-0AA0 50 3VA5250-5ED31-0AA0 3VA5250-6ED31-0AA0 3VA5250-7ED31-0AA0 60 3VA5260-5ED31-0AA0 3VA5260-6ED31-0AA0 3VA5260-7ED31-0AA0 70 3VA5270-5ED31-0AA0 3VA5270-6ED31-0AA0 3VA5270-7ED31-0AA0 80 3VA5280-5ED31-0AA0 3VA5280-6ED31-0AA0 3VA5280-7ED31-0AA0 90 3VA5290-5ED31-0AA0 3VA5290-6ED31-0AA0 3VA5290-7ED31-0AA0 100 3VA5210-5ED31-0AA0 3VA5210-6ED31-0AA0 3VA5210-7ED31-0AA0 110 3VA5211-5ED31-0AA0 3VA5211-6ED31-0AA0 3VA5211-7ED31-0AA0 125 3VA5212-5ED31-0AA0 3VA5212-6ED31-0AA0 3VA5212-7ED31-0AA0 150 3VA5215-5ED31-0AA0 3VA5215-6ED31-0AA0 3VA5215-7ED31-0AA0 175 3VA5217-5ED31-0AA0 3VA5217-6ED31-0AA0 3VA5217-7ED31-0AA0 200 3VA5220-5ED31-0AA0 3VA5220-6ED31-0AA0 3VA5220-7ED31-0AA0 225 3VA5222-5ED31-0AA0 3VA5222-6ED31-0AA0 3VA5222-7ED31-0AA0 250 3VA5225-5ED31-0AA0 3VA5225-6ED31-0AA0 3VA5225-7ED31-0AA0 TM230 FTAMa 70 3VA5270-5EC31-0AA0 3VA5270-6EC31-0AA0 3VA5270-7EC31-0AA0 80 3VA5280-5EC31-0AA0 3VA5280-6EC31-0AA0 3VA5280-7EC31-0AA0 90 3VA5290-5EC31-0AA0 3VA5290-6EC31-0AA0 3VA5290-7EC31-0AA0 100 3VA5210-5EC31-0AA0 3VA5210-6EC31-0AA0 3VA5210-7EC31-0AA0 110 3VA5211-5EC31-0AA0 3VA5211-6EC31-0AA0 3VA5211-7EC31-0AA0 125 3VA5212-5EC31-0AA0 3VA5212-6EC31-0AA0 3VA5212-7EC31-0AA0 150 3VA5215-5EC31-0AA0 3VA5215-6EC31-0AA0 3VA5215-7EC31-0AA0 175 3VA5217-5EC31-0AA0 3VA5217-6EC31-0AA0 3VA5217-7EC31-0AA0 200 3VA5220-5EC31-0AA0 3VA5220-6EC31-0AA0 3VA5220-7EC31-0AA0 225 3VA5222-5EC31-0AA0 3VA5222-6EC31-0AA0 3VA5222-7EC31-0AA0 250 3VA5225-5EC31-0AA0 3VA5225-6EC31-0AA0 3VA5225-7EC31-0AA0 TM240 ATAM 70 3VA5270-5EF31-0AA0 3VA5270-6EF31-0AA0 3VA5270-7EF31-0AA0 80 3VA5280-5EF31-0AA0 3VA5280-6EF31-0AA0 3VA5280-7EF31-0AA0 100 3VA5210-5EF31-0AA0 3VA5210-6EF31-0AA0 3VA5210-7EF31-0AA0 125 3VA5212-5EF31-0AA0 3VA5212-6EF31-0AA0 3VA5212-7EF31-0AA0 150 3VA5215-5EF31-0AA0 3VA5215-6EF31-0AA0 3VA5215-7EF31-0AA0 175 3VA5217-5EF31-0AA0 3VA5217-6EF31-0AA0 3VA5217-7EF31-0AA0 200 3VA5220-5EF31-0AA0 3VA5220-6EF31-0AA0 3VA5220-7EF31-0AA0 250 3VA5225-5EF31-0AA0 3VA5225-6EF31-0AA0 3VA5225-7EF31-0AA0 Dimensions Breaker 3VA52 3VA52 Poles 2(3-) pole 3-pole W in. (mm) 4.1 (105) 4.1 (105) H in. (mm) 7.3 (185) 7.3 (185) D in. (mm) 3.3 (83) 3.3 (83) Shipping Weight lbs. kg 4.1 1.9 4.5 2.1 Enclosures (3-pole only) Nema Type 1 surface 1 flush 3R 12 4X (304) 4X (316) Neutral 200% Neutral Catalog Number 3VAE250N1S 3VAE250N1F 3VAE250N3R 3VAE250N12 3VAE250N4X 3VAE250N4X316 N250X N2250X MOLDED CASE 7 CIRCUIT BREAKERS a Available with NAVAL/50C ratings. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-59 MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers 3VA52 250A Thermal-magnetic Trip Circuit Breakers 3VA52 250A Frame, 4-pole Thermal-Magnetic Trip Unit Cont. Ampere Rating 40 45 50 60 70 80 90 100 110 125 150 175 200 225 250 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 90 100 110 125 150 175 200 225 250 70 80 100 125 150 175 200 250 100 125 150 175 200 250 M-Interrupting Class (MFAS) Catalog Number 3VA5240-5ED41-0AA0 3VA5245-5ED41-0AA0 3VA5250-5ED41-0AA0 3VA5260-5ED41-0AA0 3VA5270-5ED41-0AA0 3VA5280-5ED41-0AA0 3VA5290-5ED41-0AA0 3VA5210-5ED41-0AA0 3VA5211-5ED41-0AA0 3VA5212-5ED41-0AA0 3VA5215-5ED41-0AA0 3VA5217-5ED41-0AA0 3VA5220-5ED41-0AA0 3VA5222-5ED41-0AA0 3VA5225-5ED41-0AA0 3VA5290-5GD41-0AA0 3VA5210-5GD41-0AA0 3VA5211-5GD41-0AA0 3VA5212-5GD41-0AA0 3VA5215-5GD41-0AA0 3VA5217-5GD41-0AA0 3VA5220-5GD41-0AA0 3VA5222-5GD41-0AA0 3VA5225-5GD41-0AA0 3VA5270-5EC41-0AA0 3VA5280-5EC41-0AA0 3VA5290-5EC41-0AA0 3VA5210-5EC41-0AA0 3VA5211-5EC41-0AA0 3VA5212-5EC41-0AA0 3VA5215-5EC41-0AA0 3VA5217-5EC41-0AA0 3VA5220-5EC41-0AA0 3VA5222-5EC41-0AA0 3VA5225-5EC41-0AA0 3VA5290-5GC41-0AA0 3VA5210-5GC41-0AA0 3VA5211-5GC41-0AA0 3VA5212-5GC41-0AA0 3VA5215-5GC41-0AA0 3VA5217-5GC41-0AA0 3VA5220-5GC41-0AA0 3VA5222-5GC41-0AA0 3VA5225-5GC41-0AA0 3VA5270-5EF41-0AA0 3VA5280-5EF41-0AA0 3VA5210-5EF41-0AA0 3VA5212-5EF41-0AA0 3VA5215-5EF41-0AA0 3VA5217-5EF41-0AA0 3VA5220-5EF41-0AA0 3VA5225-5EF41-0AA0 3VA5210-5GF41-0AA0 3VA5212-5GF41-0AA0 3VA5215-5GF41-0AA0 3VA5217-5GF41-0AA0 3VA5220-5GF41-0AA0 3VA5225-5GF41-0AA0 H-Interrupting Class (HFAS) Catalog Number TM210 FTFM 3VA5240-6ED41-0AA0 3VA5245-6ED41-0AA0 3VA5250-6ED41-0AA0 3VA5260-6ED41-0AA0 3VA5270-6ED41-0AA0 3VA5280-6ED41-0AA0 3VA5290-6ED41-0AA0 3VA5210-6ED41-0AA0 3VA5211-6ED41-0AA0 3VA5212-6ED41-0AA0 3VA5215-6ED41-0AA0 3VA5217-6ED41-0AA0 3VA5220-6ED41-0AA0 3VA5222-6ED41-0AA0 3VA5225-6ED41-0AA0 TM210 FTFM 100% Neutral 3VA5290-6GD41-0AA0 3VA5210-6GD41-0AA0 3VA5211-6GD41-0AA0 3VA5212-6GD41-0AA0 3VA5215-6GD41-0AA0 3VA5217-6GD41-0AA0 3VA5220-6GD41-0AA0 3VA5222-6GD41-0AA0 3VA5225-6GD41-0AA0 TM230 FTAM 3VA5270-6EC41-0AA0 3VA5280-6EC41-0AA0 3VA5290-6EC41-0AA0 3VA5210-6EC41-0AA0 3VA5211-6EC41-0AA0 3VA5212-6EC41-0AA0 3VA5215-6EC41-0AA0 3VA5217-6EC41-0AA0 3VA5220-6EC41-0AA0 3VA5222-6EC41-0AA0 3VA5225-6EC41-0AA0 TM230 FTAM 100% Neutral 3VA5290-6GC41-0AA0 3VA5210-6GC41-0AA0 3VA5211-6GC41-0AA0 3VA5212-6GC41-0AA0 3VA5215-6GC41-0AA0 3VA5217-6GC41-0AA0 3VA5220-6GC41-0AA0 3VA5222-6GC41-0AA0 3VA5225-6GC41-0AA0 TM240 ATAM 3VA5270-6EF41-0AA0 3VA5280-6EF41-0AA0 3VA5210-6EF41-0AA0 3VA5212-6EF41-0AA0 3VA5215-6EF41-0AA0 3VA5217-6EF41-0AA0 3VA5220-6EF41-0AA0 3VA5225-6EF41-0AA0 TM240 ATAM 100% Neutral 3VA5210-6GF41-0AA0 3VA5212-6GF41-0AA0 3VA5215-6GF41-0AA0 3VA5217-6GF41-0AA0 3VA5220-6GF41-0AA0 3VA5225-6GF41-0AA0 C-Interrupting Class (CFAS) Catalog Number 3VA5240-7ED41-0AA0 3VA5245-7ED41-0AA0 3VA5250-7ED41-0AA0 3VA5260-7ED41-0AA0 3VA5270-7ED41-0AA0 3VA5280-7ED41-0AA0 3VA5290-7ED41-0AA0 3VA5210-7ED41-0AA0 3VA5211-7ED41-0AA0 3VA5212-7ED41-0AA0 3VA5215-7ED41-0AA0 3VA5217-7ED41-0AA0 3VA5220-7ED41-0AA0 3VA5222-7ED41-0AA0 3VA5225-7ED41-0AA0 3VA5290-7GD41-0AA0 3VA5210-7GD41-0AA0 3VA5211-7GD41-0AA0 3VA5212-7GD41-0AA0 3VA5215-7GD41-0AA0 3VA5217-7GD41-0AA0 3VA5220-7GD41-0AA0 3VA5222-7GD41-0AA0 3VA5225-7GD41-0AA0 3VA5270-7EC41-0AA0 3VA5280-7EC41-0AA0 3VA5290-7EC41-0AA0 3VA5210-7EC41-0AA0 3VA5211-7EC41-0AA0 3VA5212-7EC41-0AA0 3VA5215-7EC41-0AA0 3VA5217-7EC41-0AA0 3VA5220-7EC41-0AA0 3VA5222-7EC41-0AA0 3VA5225-7EC41-0AA0 3VA5290-7GC41-0AA0 3VA5210-7GC41-0AA0 3VA5211-7GC41-0AA0 3VA5212-7GC41-0AA0 3VA5215-7GC41-0AA0 3VA5217-7GC41-0AA0 3VA5220-7GC41-0AA0 3VA5222-7GC41-0AA0 3VA5225-7GC41-0AA0 3VA5270-7EF41-0AA0 3VA5280-7EF41-0AA0 3VA5210-7EF41-0AA0 3VA5212-7EF41-0AA0 3VA5215-7EF41-0AA0 3VA5217-7EF41-0AA0 3VA5220-7EF41-0AA0 3VA5225-7EF41-0AA0 3VA5210-7GF41-0AA0 3VA5212-7GF41-0AA0 3VA5215-7GF41-0AA0 3VA5217-7GF41-0AA0 3VA5220-7GF41-0AA0 3VA5225-7GF41-0AA0 7-60 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Revised on 07/31/19 Selection 3VA Molded Case Circuit Breakers 3VA52 250A Thermal-magnetic Trip Circuit Breakers Revised on 04/30/21 Technical information Interrupting Ratings for 3VA52 Interrupting Class M H C Breaker Type MFAS HFAS CFAS RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240 480Y/277V 480 85 35 35 100 65 65 200 100 100 600Y/347V 18 25 35 600 18 25 35 Volts DC 250 50 85 100 500 50 85 100 600 (3P) 50 85 100 Trip Settings for 3VA52 TM210 - FTFM In (A) 40 50 60 70 80 90 100 110 125 150 175 200 225 250 Ir (A) 40 50 60 70 80 90 100 110 125 150 175 200 225 250 Ii (A) 400 500 600 700 800 900 1000 1100 1250 1500 1750 2000 2250 2500 TM230 - FTAM In (A) 70 80 90 100 110 125 150 175 200 225 250 Ir (A) 70 80 90 100 110 125 150 175 200 225 250 Ii (A) 350 400 450 500 550 625 750 875 1000 1125 1250 420 480 540 600 660 750 900 1050 1200 1350 1500 490 560 630 700 770 875 1050 1225 1400 1575 1750 560 640 720 800 880 1000 1200 1400 1600 1800 2000 630 720 810 900 990 1125 1350 1575 1800 2025 2250 700 800 900 1000 1100 1250 1500 1750 2000 2250 2500 TM240 - ATAM Ir (A) Ir (A) In (A) 90% 80% 70 63 56 80 72 64 100 90 80 125 113 100 150 135 120 175 158 140 200 180 160 250 225 200 Ii (A) 350 400 500 625 750 875 1000 1250 420 480 600 750 900 1050 1200 1500 490 560 700 875 1050 1225 1400 1750 560 640 800 1000 1200 1400 1600 2000 630 720 900 1125 1350 1575 1800 2250 700 800 1000 1250 1500 1750 2000 2500 3VA UL Molded Case Circuit Breakers Accessories and Spare Parts Internal accessories Connectors for 75C Wire for 3VA52 Design Type Steel wrap around (Cu cable only), single cable lugs Aluminum body lug (Cu/Al cable), single cable lugs Aluminum body lug (Cu/Al cable) with control wire tap, single cable lugs Aluminum body lug large (Cu/Al cable) single cable lugs with 1 extended terminal cover Aluminum body lug large with control wire tap (Cu/Al cable) single cable lugs and 1 extended terminal cover Aluminum body lug, 2 cables (Cu/Al cable) with control wire tap and 1 extended terminal cover Distribution lug, 6 Cables (Cu/Al cable) with 1 extended terminal cover Copper body lug (Cu cable only) single cable lugs Copper body lug with control wire tap (Cu cable only) single cable lugs Minimum cable size AWG 10 AWG 4 AWG 14 AWG 6 AWG 14 AWG 6 AWG 2 AWG 2 AWG 4 AWG 14 AWG 14 AWG 6 AWG 14 AWG 6 Maximum Part Number cable size (kit of 3 lugs) 3/0 3VA9233-0JA11 350 kcmil 3VA9233-0JA12 1/0 3VA9233-0JB11 350 kcmil 3VA9233-0JB12a 1/0 3VA9233-0JG11 350 kcmil 3VA9233-0JG12 350 kcmil 3VA9233-0JJ13 350 kcmil 3VA9233-0JC13 300 kcmil 3VA9233-0JJ22 AWG 2 3VA9233-0JF60 1/0 3VA9233-0JD11 350 kcmil 3VA9233-0JD12 1/0 3VA9233-0JK11 350 kcmil 3VA9233-0JK12 Part Number (kit of 4 lugs) 3VA9234-0JA11 3VA9234-0JA12 3VA9234-0JB11 3VA9234-0JB12a 3VA9234-0JG11 3VA9234-0JG12 3VA9234-0JJ13 3VA9234-0JC13 3VA9234-0JJ22 3VA9234-0JF60 4 3VA9234-0JD11 3VA9234-0JD12 3VA9234-0JK11 3VA9234-0JK12 See page 7-83 for internal accessory part numbers. Internal accessories Optional equipment 3VA5 250 A 2(3)-pole & 3-pole Auxiliary switch Auxiliary switch Leading changeover switch Alarm switch Trip alarm switch Auxiliary release Shunt trip flexible Shunt trip left Undervoltage release Universal release Other Cylinder lock (type Ronis) Slot No.: Type AUX_HQ AUX_HQ_el AUX_HP LCS_HQ LCS_HQ_el LCS_HP Type TAS_HQ TAS_HQ_el TAS_HP Type STF 250 A 24 23 22 21 11 12 13 14 xxxx xxxx x x x xxxx xxxx xx x x x x xx xx x xx xx x x STL x UVR x UNI x x I201_19494 a Standard lug installed at the factory when breaker ordered with a "6" in the 12th position. MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-61 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA62 250A Electronic Trip Circuit Breakers Selection 3VA62 250A 3-Pole Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers without lugs. For factory installed nut keepers (3VA92430QA00), change the 12th digit of the catalog number to "2" (required to install a breaker in a panelboard or switchboard that has a provision). (For example, a 35KA @480VAC, 250A, 3-pole, 3VA62 with nut keepers would be catalog number 3VA6225-5HL32-0AA0). For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 250A, 3-pole, 3VA62 with lugs would be catalog number 3VA6225-5HL36-0AA0). Alternate connectors can be ordered separately for field installation. All 3VA62 electronic trip circuit breakers are available with 100% ratings. For 100% rated electronic trip circuit breakers, change the 13th digit of the catalog number to the number "2". (For example, a 35KA @480VAC, 250A, 3-pole, 100% rated 3VA62 would be catalog number 3VA6225-5HL31-2AA0). Requires the use of rated lugs -- see lug table below. All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked "Naval", and are suitable for use at 50C. All 3VA62 electronic trip circuit breakers are UL listed for reverse feed applications. 3VA62 250A Frame 3-Pole Electronic Trip Unit Continuous Ampere M-Interrupting Class (MFAE) Catalog Number H-Interrupting Class (HFAE) Catalog Number C-Interrupting Class (CFAE) Catalog Number L-Interrupting Class (LFAE) Catalog Number ETU320 LI with dials 100 3VA6210-5HL31-0AA0 3VA6210-6HL31-0AA0 3VA6210-7HL31-0AA0 3VA6210-8HL31-0AA0 250 3VA6225-5HL31-0AA0 3VA6225-6HL31-0AA0 3VA6225-7HL31-0AA0 3VA6225-8HL31-0AA0 ETU330 LIG with dials 100 3VA6210-5HM31-0AA0 3VA6210-6HM31-0AA0 3VA6210-7HM31-0AA0 3VA6210-8HM31-0AA0 250 3VA6225-5HM31-0AA0 3VA6225-6HM31-0AA0 3VA6225-7HM31-0AA0 3VA6225-8HM31-0AA0 ETU350 LSI with dials 100 3VA6210-5HN31-0AA0 3VA6210-6HN31-0AA0 3VA6210-7HN31-0AA0 3VA6210-8HN31-0AA0 250 3VA6225-5HN31-0AA0 3VA6225-6HN31-0AA0 3VA6225-7HN31-0AA0 3VA6225-8HN31-0AA0 ETU550 LSI with LCD 100 3VA6210-5JP31-0AA0 3VA6210-6JP31-0AA0 3VA6210-7JP31-0AA0 3VA6210-8JP31-0AA0 250 3VA6225-5JP31-0AA0 3VA6225-6JP31-0AA0 3VA6225-7JP31-0AA0 3VA6225-8JP31-0AA0 ETU556 LSI(G Alarm) with LCD 100 3VA6210-5JT31-0AA0 3VA6210-6JT31-0AA0 3VA6210-7JT31-0AA0 3VA6210-8JT31-0AA0 250 3VA6225-5JT31-0AA0 3VA6225-6JT31-0AA0 3VA6225-7JT31-0AA0 3VA6225-8JT31-0AA0 ETU560 LSIG with LCD 100 3VA6210-5JQ31-0AA0 3VA6210-6JQ31-0AA0 3VA6210-7JQ31-0AA0 3VA6210-8JQ31-0AA0 250 3VA6225-5JQ31-0AA0 3VA6225-6JQ31-0AA0 3VA6225-7JQ31-0AA0 3VA6225-8JQ31-0AA0 ETU820 LI with LCD and Metering 100 3VA6210-5KL31-0AA0 3VA6210-6KL31-0AA0 3VA6210-7KL31-0AA0 3VA6210-8KL31-0AA0 250 3VA6225-5KL31-0AA0 3VA6225-6KL31-0AA0 3VA6225-7KL31-0AA0 3VA6225-8KL31-0AA0 ETU830 LIG with LCD and Metering 100 3VA6210-5KM31-0AA0 3VA6210-6KM31-0AA0 3VA6210-7KM31-0AA0 3VA6210-8KM31-0AA0 250 3VA6225-5KM31-0AA0 3VA6225-6KM31-0AA0 3VA6225-7KM31-0AA0 3VA6225-8KM31-0AA0 ETU850 LSI with LCD and Metering 100 3VA6210-5KP31-0AA0 3VA6210-6KP31-0AA0 3VA6210-7KP31-0AA0 3VA6210-8KP31-0AA0 250 3VA6225-5KP31-0AA0 3VA6225-6KP31-0AA0 3VA6225-7KP31-0AA0 3VA6225-8KP31-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 100 3VA6210-5KT31-0AA0 3VA6210-6KT31-0AA0 3VA6210-7KT31-0AA0 3VA6210-8KT31-0AA0 250 3VA6225-5KT31-0AA0 3VA6225-6KT31-0AA0 3VA6225-7KT31-0AA0 3VA6225-8KT31-0AA0 ETU860 LSIG with LCD and Metering 100 3VA6210-5KQ31-0AA0 3VA6210-6KQ31-0AA0 3VA6210-7KQ31-0AA0 3VA6210-8KQ31-0AA0 250 3VA6225-5KQ31-0AA0 3VA6225-6KQ31-0AA0 3VA6225-7KQ31-0AA0 3VA6225-8KQ31-0AA0 E-Interrupting Class (EFAE) Catalog Number -- 3VA6225-0HL31-0AA0 -- 3VA6225-0HM31-0AA0 -- 3VA6225-0HN31-0AA0 -- -- -- -- -- -- -- -- -- -- -- -- -- 3VA6225-0KT31-0AA0 -- 3VA6225-0KQ31-0AA0 MOLDED CASE 7 CIRCUIT BREAKERS 7-62 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA62 250A Electronic Trip Circuit Breakers Revised on 04/30/21 Selection MOLDED CASE 7 CIRCUIT BREAKERS 3VA62 250A 4-Pole 3VA62 250A Frame 4-Pole Electronic Trip Unit Continuous Ampere M-Interrupting Class (MFAE) Catalog Number H-Interrupting Class (HFAE) Catalog Number C-Interrupting Class (CFAE) Catalog Number ETU320 LI with dials 100 3VA6210-5HL41-0AA0 3VA6210-6HL41-0AA0 3VA6210-7HL41-0AA0 250 3VA6225-5HL41-0AA0 3VA6225-6HL41-0AA0 3VA6225-7HL41-0AA0 ETU330 LIG with dials 100 3VA6210-5HM41-0AA0 3VA6210-6HM41-0AA0 3VA6210-7HM41-0AA0 250 3VA6225-5HM41-0AA0 3VA6225-6HM41-0AA0 3VA6225-7HM41-0AA0 ETU350 LSI with dials 100 3VA6210-5HN41-0AA0 3VA6210-6HN41-0AA0 3VA6210-7HN41-0AA0 250 3VA6225-5HN41-0AA0 3VA6225-6HN41-0AA0 3VA6225-7HN41-0AA0 L-Interrupting Class (LFAE) Catalog Number 3VA6210-8HL41-0AA0 3VA6225-8HL41-0AA0 3VA6210-8HM41-0AA0 3VA6225-8HM41-0AA0 3VA6210-8HN41-0AA0 3VA6225-8HN41-0AA0 ETU550 LSI with LCD 100 3VA6210-5JP41-0AA0 3VA6210-6JP41-0AA0 3VA6210-7JP41-0AA0 3VA6210-8JP41-0AA0 250 3VA6225-5JP41-0AA0 3VA6225-6JP41-0AA0 3VA6225-7JP41-0AA0 3VA6225-8JP41-0AA0 ETU556 LSI(G Alarm) with LCD 100 3VA6210-5JT41-0AA0 3VA6210-6JT41-0AA0 3VA6210-7JT41-0AA0 3VA6210-8JT41-0AA0 250 3VA6225-5JT41-0AA0 3VA6225-6JT41-0AA0 3VA6225-7JT41-0AA0 3VA6225-8JT41-0AA0 ETU560 LSIG with LCD 100 3VA6210-5JQ41-0AA0 3VA6210-6JQ41-0AA0 3VA6210-7JQ41-0AA0 3VA6210-8JQ41-0AA0 250 3VA6225-5JQ41-0AA0 3VA6225-6JQ41-0AA0 3VA6225-7JQ41-0AA0 3VA6225-8JQ41-0AA0 ETU820 LI with LCD and Metering 100 3VA6210-5KL41-0AA0 3VA6210-6KL41-0AA0 3VA6210-7KL41-0AA0 3VA6210-8KL41-0AA0 250 3VA6225-5KL41-0AA0 3VA6225-6KL41-0AA0 3VA6225-7KL41-0AA0 3VA6225-8KL41-0AA0 ETU830 LIG with LCD and Metering 100 3VA6210-5KM41-0AA0 3VA6210-6KM41-0AA0 3VA6210-7KM41-0AA0 3VA6210-8KM41-0AA0 250 3VA6225-5KM41-0AA0 3VA6225-6KM41-0AA0 3VA6225-7KM41-0AA0 3VA6225-8KM41-0AA0 ETU850 LSI with LCD and Metering 100 3VA6210-5KP41-0AA0 3VA6210-6KP41-0AA0 3VA6210-7KP41-0AA0 3VA6210-8KP41-0AA0 250 3VA6225-5KP41-0AA0 3VA6225-6KP41-0AA0 3VA6225-7KP41-0AA0 3VA6225-8KP41-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 100 3VA6210-5KT41-0AA0 3VA6210-6KT41-0AA0 3VA6210-7KT41-0AA0 3VA6210-8KT41-0AA0 250 3VA6225-5KT41-0AA0 3VA6225-6KT41-0AA0 3VA6225-7KT41-0AA0 3VA6225-8KT41-0AA0 ETU860 LSIG with LCD and Metering 100 3VA6210-5KQ41-0AA0 3VA6210-6KQ41-0AA0 3VA6210-7KQ41-0AA0 3VA6210-8KQ41-0AA0 250 3VA6225-5KQ41-0AA0 3VA6225-6KQ41-0AA0 3VA6225-7KQ41-0AA0 3VA6225-8KQ41-0AA0 E-Interrupting Class (EFAE) Catalog Number -- 3VA6225-0HL41-0AA0 -- 3VA6225-0HM41-0AA0 -- 3VA6225-0HN41-0AA0 -- -- -- -- -- -- -- -- -- -- -- -- -- 3VA6225-0KT41-0AA0 -- 3VA6225-0KQ41-0AA0 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-63 3VA Molded Case Circuit Breakers 3VA62 250A Electronic Trip Circuit Breakers Revised on 04/30/21 Technical information Connectors for 75C wire for 3VA62 Type Steel Wrap around (Cu cable only) single cable lugsa Steel Wrap around (Cu cable only) single cable lugs with control wire tap Aluminum Body Lug (Cu/Al cable) single cable lugsa Aluminum body lug with control wire tap (Cu/Al cable) single cable lugsa Aluminum body lug large (Cu/Al cable) single cable lugs and 1 ext'd terminal covera Aluminum body lug large with control wire tap (Cu/Al cable) single cable lugs and 1 extended terminal covera Aluminum body lug, 2 cables (Cu/Al cable) with 1 extended terminal covera Aluminum body lug, 2 cables (Cu/Al cable) with control wire tap and 1 extended terminal covera Distribution lug, 6 Cables (Cu/Al cable) with 1 extended terminal covera Copper body lug (Cu cable only) single cable lugs Copper body lug (Cu cable only) with control wire tap single cable lugs Minimum cable size AWG 10 AWG 4 AWG 10 AWG 4 AWG 14 AWG 6 AWG 14 AWG 6 AWG 2 AWG 2 AWG 4 AWG 4 AWG 14 AWG 14 AWG 6 AWG 14 AWG 6 Maximum cable size 3/0 350 kcmil 3/0 350 kcmil 1/0 350 kcmil 1/0 350 kcmil 350 kcmil 350 kcmil 300 kcmil 300 kcmil AWG 2 1/0 350 kcmil 1/0 350 kcmil Part Number (kit of 3 lugs) 3VA9143-0JA12 3VA9243-0JA12 3VA9143-0JH12 3VA9243-0JH12 3VA9143-0JB11 3VA9243-0JB12c 3VA9143-0JG11 3VA9243-0JG12 3VA9243-0JJ13 3VA9243-0JC13 3VA9243-0JJ22 3VA9243-0JC22 3VA9243-0JF60 3VA9143-0JD11a 3VA9243-0JD12bd 3VA9143-0JK11a 3VA9243-0JK12b Part Number (kit of 4 lugs) 3VA9144-0JA12 3VA9244-0JA12 3VA9144-0JH12 3VA9244-0JH12 3VA9144-0JB11 3VA9244-0JB12c 3VA9144-0JG11 3VA9244-0JG12 3VA9244-0JJ13 3VA9244-0JC13 3VA9244-0JJ22 3VA9244-0JC22 3VA9244-0JF60 3VA9144-0JD11a 3VA9244-0JD12bd 3VA9144-0JK11a 3VA9244-0JK12b Interrupting Ratings for 3VA62 Interrupting Class M H C L E Breaker Type MFAE HFAE CFAE LFAE EFAE RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240 480Y/277V 480 100 35 35 100 65 65 200 100 100 200 150 150 -- 200 200 600Y/347V 18 22 35 50 100 600 18 22 35 50 100 Dimensions Breaker 3VA62 3VA62 Poles 3 4 W in. (mm) 4.1 (105) 5.5 (140) H in. (mm) 7.8 (198) 7.8 (198) D in. (mm) 3.4 (86) 3.4 (86) Shipping Weight lbs. kg 5.5 2.5 7.1 3.2 Enclosures (3-pole only) Nema Type 1 surface 1 flush 3R 12 4X (304) 4X (316) Neutral 200% Neutral Catalog Number 3VAE250N1S 3VAE250N1F 3VAE250N3R 3VAE250N12 3VAE250N4X 3VAE250N4X316 N250X N2250X MOLDED CASE 7 CIRCUIT BREAKERS a Meets requirements for 100% rated breakers up to 100A. b Meets requirements for 100% rated breakers up to 250A, requires the use of 90 degree wire. c Standard lug installed at the factory when breaker ordered with a "6" in the 12th position. 7-64 Siemens Industry, Inc. SPEEDFAXTM Product Catalog d Standard lug installed at the factory on 250A 100% rated breaker when ordered with a "6" in the 12th position. 3VA Molded Case Circuit Breakers 3VA62 250A Electronic Trip Circuit Breakers Revised on 01/31/21 Technical information Trip Settings for 3VA62 ETU320-LI, ETU330-LIG, ETU350-LSI Continuous Amperage LI, LIG, LSI In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I)a 100 40 - 100 0.5 - 17 150-1200 250 100 - 250 0.5 - 13 375-2500 a Ii for ETU350 is fixed at the maximum level shown in table. LSI Isd= xIr (Amp) (S) 1.5 - 10 1.5 - 10 LI, LIG, LSI LIG 4P only tsd (sec) (S) 0.08 - 0.4 Ig (Amp) (G) 20 - 100 50 - 250 IN=xIr (Amp) 0.5 - 1 / OFF 0.5 - 1 / OFF ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG Continuous Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G) LSI 3P with External CT LI, LIG, LSI, LSIG, LSI(G) 4P only In (Amp) Ir(Amp) (L)b tld (sec) (L) Ii (Amp) (I) Isd (Amp) (S) tsd (sec) (S) Ig (Amp) (G) tg (G) IN=xIr (Amp) IN (Amp) 100 40 - 100 0.5 - 25 150-1200 60 - 1000 0.05 - 0.5 20 - 100 0.05 - 0.8 20 - 160 / OFF 20 - 160 / OFF 250 100 - 250 0.5 - 13 375-2500 150 - 2500 50 - 250 50 - 400 / OFF 50 - 250 / OFF b Adjustable in steps of 1A. 3VA UL Molded Case Circuit Breakers For specific trip settings refer to the Electronic Trip Unit section of the 3VAAScycsetesmsosriMesanaunadl,Spare Parts which can be found in the document download center at https://digitalcontentcenter.compas.siemens-info.com/SIE_IM_3VA6_Systems_Manual.pdf Internal accessories Internal accessories Optional equipment 3VA6 150/250 A 3-pole 3VA6 150/250 A 4-pole Auxiliary switch Auxiliary switch Leading changeover switch Alarm switch Trip alarm switch Electrical alarm switch Auxiliary release Shunt trip flexible Slot No.: Type AUX_HQ AUX_HQ_el AUX_HP LCS_HQ LCS_HQ_el LCS_HP Type TAS_HQ TAS_HQ_el TAS_HP EAS_HQ EAS_HQ_el Type 250 A 250 A 24 23 22 21 11 12 13 14 34 33 32 31 24 23 22 21 11 12 13 14 xxxx xxxx x x x xxxx xxxx xx x x x x xxxx xxxx x x x xxxx xxxx x x x xxxx xxxx xx x x x x xx xx xx xx x x x x xx xx xx xx x x x x STF x x x x Shunt trip left Undervoltage release Universal release ETU/communication Communication module Breaker data server 24 V module Other Cylinder lock (type Ronis) STL x UVR x UNI x Type COM060 x x x See page 7-83 for internal accessory part numbers. x 4 x x x x x I201_19495 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-65 3VA Molded Case Circuit Breakers 3VA53 400A Thermal-magnetic Trip Circuit Breakers Revised on 04/30/21 Selection 3VA53 400A, 2-Pole in 3-Pole Frame, Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MJAS) Catalog Number H-Interrupting Class (HJAS) Catalog Number C-Interrupting Class (CJAS) Catalog Number TM230 FTAM 200 3VA5320-5EC61-0AA0 3VA5320-6EC61-0AA0 3VA5320-7EC61-0AA0 225 3VA5322-5EC61-0AA0 3VA5322-6EC61-0AA0 3VA5322-7EC61-0AA0 250 3VA5325-5EC61-0AA0 3VA5325-6EC61-0AA0 3VA5325-7EC61-0AA0 300 3VA5330-5EC61-0AA0 3VA5330-6EC61-0AA0 3VA5330-7EC61-0AA0 350 3VA5335-5EC61-0AA0 3VA5335-6EC61-0AA0 3VA5335-7EC61-0AA0 400 3VA5340-5EC61-0AA0 3VA5340-6EC61-0AA0 3VA5340-7EC61-0AA0 3VA53 400A Frame, 3-Pole Frame, Thermal-Magnetic Trip Unit Cont. Ampere Rating 200 225 250 300 350 400 200 225 250 300 350 400 M-Interrupting Class (MJAS) Catalog Number 3VA5320-5EC31-0AA0 3VA5322-5EC31-0AA0 3VA5325-5EC31-0AA0 3VA5330-5EC31-0AA0 3VA5335-5EC31-0AA0 3VA5340-5EC31-0AA0 3VA5320-5EF31-0AA0 3VA5322-5EF31-0AA0 3VA5325-5EF31-0AA0 3VA5330-5EF31-0AA0 3VA5335-5EF31-0AA0 3VA5340-5EF31-0AA0 H-Interrupting Class (HJAS) Catalog Number TM230 FTAMa 3VA5320-6EC31-0AA0 3VA5322-6EC31-0AA0 3VA5325-6EC31-0AA0 3VA5330-6EC31-0AA0 3VA5335-6EC31-0AA0 3VA5340-6EC31-0AA0 TM240 ATAM 3VA5320-6EF31-0AA0 3VA5322-6EF31-0AA0 3VA5325-6EF31-0AA0 3VA5330-6EF31-0AA0 3VA5335-6EF31-0AA0 3VA5340-6EF31-0AA0 C-Interrupting Class (CJAS) Catalog Number 3VA5320-7EC31-0AA0 3VA5322-7EC31-0AA0 3VA5325-7EC31-0AA0 3VA5330-7EC31-0AA0 3VA5335-7EC31-0AA0 3VA5340-7EC31-0AA0 3VA5320-7EF31-0AA0 3VA5322-7EF31-0AA0 3VA5325-7EF31-0AA0 3VA5330-7EF31-0AA0 3VA5335-7EF31-0AA0 3VA5340-7EF31-0AA0 Trip Settings for 3VA53 TM230 - FTAM In (Amp) 200 225 250 300 350 400 Ir(Amp) 200 225 250 300 350 400 Ii (Amp) 1000 1200 1125 1350 1250 1500 1500 1800 1750 2100 2000 2400 TM240 - ATAM In (Amp) 200 225 250 300 350 400 Ir(Amp) 90% 180 203 225 270 315 360 Ir(Amp) 80% 160 180 200 240 280 320 Ii (Amp) 1000 1200 1125 1350 1250 1500 1500 1800 1750 2100 2000 2400 1400 1575 1750 2100 2450 2800 1400 1575 1750 2100 2450 2800 1600 1800 2000 2400 2800 3200 1600 1800 2000 2400 2800 3200 1800 2025 2250 2700 3150 3600 1800 2025 2250 2700 3150 3600 2000 2250 2500 3000 3500 4000 2000 2250 2500 3000 3500 4000 3VA53 400A 3-Pole Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers without lugs. For factory installed nut keepers (3VA94730QA00), change the 12th digit of the catalog number to "2" (required to install a breaker in a panelboard or switchboard that has a provision). (For example, a 35KA @480VAC, 400A, 3-pole, 3VA53 with nut keepers would be catalog number 3VA5340-5EC32-0AA0). For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 400A, 3-pole, 3VA53 with lugs would be catalog number 3VA5340-5EC36-0AA0). Alternate connectors can be ordered separately for field installation. For NAVAL-rated thermal-magnetic trip circuit breakers, change the 13th digit of the catalog number to the number "1". (For example, a 35KA @480VAC, 400A, 3-pole, NAVAL rated 3VA53 would be catalog number 3VA5340-5EC31-1AA0) All 3VA53 thermal-magnetic trip circuit breakers are UL listed for reverse feed applications. MOLDED CASE 7 CIRCUIT BREAKERS a Available with NAVAL/50C ratings. 7-66 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA53 400A Thermal-magnetic Trip Circuit Breakers Revised on 06/30/21 Selection 3VA53 400A Frame, 4-Pole Frame, Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MJAS) Catalog Number H-Interrupting Class (HJAS) Catalog Number C-Interrupting Class (CJAS) Catalog Number TM230 FTAM Unprotected Neutral 200 3VA5320-5EC41-0AA0 3VA5320-6EC41-0AA0 3VA5320-7EC41-0AA0 225 3VA5322-5EC41-0AA0 3VA5322-6EC41-0AA0 3VA5322-7EC41-0AA0 250 3VA5325-5EC41-0AA0 3VA5325-6EC41-0AA0 3VA5325-7EC41-0AA0 300 3VA5330-5EC41-0AA0 3VA5330-6EC41-0AA0 3VA5330-7EC41-0AA0 350 3VA5335-5EC41-0AA0 3VA5335-6EC41-0AA0 3VA5335-7EC41-0AA0 400 3VA5340-5EC41-0AA0 3VA5340-6EC41-0AA0 3VA5340-7EC41-0AA0 TM240 ATAM Unprotected Neutral 200 3VA5320-5EF41-0AA0 3VA5320-6EF41-0AA0 3VA5320-7EF41-0AA0 225 3VA5322-5EF41-0AA0 3VA5322-6EF41-0AA0 3VA5322-7EF41-0AA0 250 3VA5325-5EF41-0AA0 3VA5325-6EF41-0AA0 3VA5325-7EF41-0AA0 300 3VA5330-5EF41-0AA0 3VA5330-6EF41-0AA0 3VA5330-7EF41-0AA0 350 3VA5335-5EF41-0AA0 3VA5335-6EF41-0AA0 3VA5335-7EF41-0AA0 400 3VA5340-5EF41-0AA0 3VA5340-6EF41-0AA0 3VA5340-7EF41-0AA0 TM230 FTAM 100% Neutral 200 3VA5320-5GC41-0AA0 3VA5320-6GC41-0AA0 3VA5320-7GC41-0AA0 A3VcAceUssLoMrieosldaenddCSaps3aerVeCAPira5cru3tsit4B0r0eAake4r-sPole 225 3VA5322-5GC41-0AA0 3VA5322-6GC41-0AA0 3VA5322-7GC41-0AA0 250 3VA5325-5GC41-0AA0 3VA5325-6GC41-0AA0 3VA5325-7GC41-0AA0 Internal accessories 300 3VA5330-5GC41-0AA0 3VA5330-6GC41-0AA0 3VA5330-7GC41-0AA0 Internal accessories 3VA5 Optional equipment 400/600 A 350 3VA5335-5GC41-0AA0 3VA5335-6GC41-0AA0 3VA5335-7GC41-0AA0 3 & 4-pole 400 3VA5340-5GC41-0AA0 3VA5340-6GC41-0AA0 3VA5340-7GC41-0AA0 TM240 ATAM 100% Neutral 200 3VA5320-5GF41-0AA0 3VA5320-6GF41-0AA0 3VA5320-7GF41-0AA0 225 3VA5322-5GF41-0AA0 3VA5322-6GF41-0AA0 3VA5322-7GF41-0AA0 250 3VA5325-5GF41-0AA0 3VA5325-6GF41-0AA0 3VA5325-7GF41-0AA0 300 3VA5330-5GF41-0AA0 3VA5330-6GF41-0AA0 3VA5330-7GF41-0AA0 350 3VA5335-5GF41-0AA0 3VA5335-6GF41-0AA0 3VA5335-7GF41-0AA0 400 3VA5340-5GF41-0AA0 3VA5340-6GF41-0AA0 3VA5340-7GF41-0AA0 Dimensions Breaker Poles Shipping Weight W in. (mm) H in. (mm) D in. (mm) lbs. kg Auxiliary switch Auxiliary switch Leading changeover switch Alarm switch Trip alarm switch Slot No.: Type AUX_HQ AUX_HQ_el AUX_HP LCS_HQ LCS_HQ_el LCS_HP Type TAS_HQ TAS_HQ_el TAS_HP 600 A 25 24 23 22 21 11 12 13 14 15 35 34 33 32 31 2 xxxxx xxxxx x x xx xxxxx xxxxx x x xx x x x xxxxx xxxxx xx x x xx xx x xx xx x 3VA53 3 5.4 (137) 9.8 (249) 5.4 (137) 11.5 5.2 Auxiliary release Type 3VA53 4 7.2 (183) 9.8 (249) 5.4 (137) 15.0 6.8 Shunt trip flexible STF x x MOLDED CASE 7 CIRCUIT BREAKERS Interrupting Ratings for 3VA53 4 RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) Volts DC Interrupting Breaker 480Y/ 600Y/ 250 600 750 750 1000 Class Type 240 277V 480 347V 600 (2P) (3P) (3P) (4P) (4P) M MJAS 85 35 35 18 18 50 50 10 50 10 H HJAS 100 65 65 25 25 85 85 10 85 10 C CJAS 200 100 100 35 35 100 100 10 100 10 Shunt trip left STL Undervoltage release UVR Universal release UNI Other Cylinder lock (type Ronis) x x x x 4/6 Siemens · 04/2017 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-67 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA63 400A Electronic Trip Circuit Breakers Selection 3VA63 400A 3-Pole Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers without lugs. For factory installed nut keepers (3VA94730QA00), change the 12th digit of the catalog number to "2" (required to install a breaker in a panelboard or switchboard that has a provision). (For example, a 35KA @480VAC, 400A, 3-pole, 3VA63 with nut keepers would be catalog number 3VA6340-5HL32-0AA0). For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 400A, 3-pole, 3VA63 with lugs would be catalog number 3VA6340-5HL360AA0). Alternate connectors can be ordered separately for field installation. 3VA63 electronic trip circuit breakers are available with 100% ratings (up to 250A only in this frame 400A with 100% ratings can be purchased in the 600A frame). For 100% rated electronic trip circuit breakers, change the 13th digit of the catalog number to the number "2". (For example, a 35KA @480VAC, 400A, 3-pole, 100% rated 3VA63 would be catalog number 3VA6340-5HL31-2AA0). Requires the use of rated lugs -- see lug table below. All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked "Naval", and are suitable for use at 50C. All 3VA63 electronic trip circuit breakers are UL listed for reverse feed applications. 3VA63 400A Frame 3-Pole Electronic Trip Unit Continuous Ampere M-Interrupting Class (MJAE) Catalog Number H-Interrupting Class (HJAE) Catalog Number C-Interrupting Class (CJAE) Catalog Number L-Interrupting Class (LJAE) Catalog Number ETU320 LI with dials 250 3VA6325-5HL31-0AA0 3VA6325-6HL31-0AA0 3VA6325-7HL31-0AA0 3VA6325-8HL31-0AA0 400 3VA6340-5HL31-0AA0 3VA6340-6HL31-0AA0 3VA6340-7HL31-0AA0 3VA6340-8HL31-0AA0 ETU330 LIG with dials 250 3VA6325-5HM31-0AA0 3VA6325-6HM31-0AA0 3VA6325-7HM31-0AA0 3VA6325-8HM31-0AA0 400 3VA6340-5HM31-0AA0 3VA6340-6HM31-0AA0 3VA6340-7HM31-0AA0 3VA6340-8HM31-0AA0 ETU350 LSI with dials 250 3VA6325-5HN31-0AA0 3VA6325-6HN31-0AA0 3VA6325-7HN31-0AA0 3VA6325-8HN31-0AA0 400 3VA6340-5HN31-0AA0 3VA6340-6HN31-0AA0 3VA6340-7HN31-0AA0 3VA6340-8HN31-0AA0 ETU550 LSI with LCD 250 3VA6325-5JP31-0AA0 3VA6325-6JP31-0AA0 3VA6325-7JP31-0AA0 3VA6325-8JP31-0AA0 400 3VA6340-5JP31-0AA0 3VA6340-6JP31-0AA0 3VA6340-7JP31-0AA0 3VA6340-8JP31-0AA0 ETU556 LSI(G Alarm) with LCD 250 3VA6325-5JT31-0AA0 3VA6325-6JT31-0AA0 3VA6325-7JT31-0AA0 3VA6325-8JT31-0AA0 400 3VA6340-5JT31-0AA0 3VA6340-6JT31-0AA0 3VA6340-7JT31-0AA0 3VA6340-8JT31-0AA0 ETU560 LSIG with LCD 250 3VA6325-5JQ31-0AA0 3VA6325-6JQ31-0AA0 3VA6325-7JQ31-0AA0 3VA6325-8JQ31-0AA0 400 3VA6340-5JQ31-0AA0 3VA6340-6JQ31-0AA0 3VA6340-7JQ31-0AA0 3VA6340-8JQ31-0AA0 ETU820 LI with LCD and Metering 250 3VA6325-5KL31-0AA0 3VA6325-6KL31-0AA0 3VA6325-7KL31-0AA0 3VA6325-8KL31-0AA0 400 3VA6340-5KL31-0AA0 3VA6340-6KL31-0AA0 3VA6340-7KL31-0AA0 3VA6340-8KL31-0AA0 ETU830 LIG with LCD and Metering 250 3VA6325-5KM31-0AA0 3VA6325-6KM31-0AA0 3VA6325-7KM31-0AA0 3VA6325-8KM31-0AA0 400 3VA6340-5KM31-0AA0 3VA6340-6KM31-0AA0 3VA6340-7KM31-0AA0 3VA6340-8KM31-0AA0 ETU850 LSI with LCD and Metering 250 3VA6325-5KP31-0AA0 3VA6325-6KP31-0AA0 3VA6325-7KP31-0AA0 3VA6325-8KP31-0AA0 400 3VA6340-5KP31-0AA0 3VA6340-6KP31-0AA0 3VA6340-7KP31-0AA0 3VA6340-8KP31-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 250 3VA6325-5KT31-0AA0 3VA6325-6KT31-0AA0 3VA6325-7KT31-0AA0 3VA6325-8KT31-0AA0 400 3VA6340-5KT31-0AA0 3VA6340-6KT31-0AA0 3VA6340-7KT31-0AA0 3VA6340-8KT31-0AA0 ETU860 LSIG with LCD and Metering 250 3VA6325-5KQ31-0AA0 3VA6325-6KQ31-0AA0 3VA6325-7KQ31-0AA0 3VA6325-8KQ31-0AA0 400 3VA6340-5KQ31-0AA0 3VA6340-6KQ31-0AA0 3VA6340-7KQ31-0AA0 3VA6340-8KQ31-0AA0 E-Interrupting Class (EJAE) Catalog Number 3VA6325-0HL31-0AA0 3VA6340-0HL31-0AA0 3VA6325-0HM31-0AA0 3VA6340-0HM31-0AA0 3VA6325-0HN31-0AA0 3VA6340-0HN31-0AA0 -- -- -- -- -- -- -- -- -- -- -- -- 3VA6325-0KT31-0AA0 3VA6340-0KT31-0AA0 3VA6325-0KQ31-0AA0 3VA6340-0KQ31-0AA0 MOLDED CASE 7 CIRCUIT BREAKERS 7-68 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA63 400A Electronic Trip Circuit Breakers Revised on 06/30/21 Selection Interrupting Ratings for 3VA63 Interrupting Class M H C L E Breaker Type MJAE HJAE CJAE LJAE EJAE RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240 480Y/277V 480 100 35 35 100 65 65 200 100 100 200 150 150 -- 200 200 600Y/347V 18 22 35 50 100 600 18 22 35 50 100 3VA63 400A 4-Pole Dimensions Breaker 3VA63 3VA63 Poles 3 4 W in. (mm) 5.4 (137) 7.2 (183) H in. (mm) 9.8 (249) 9.8 (249) D in. (mm) 5.4 (137) 5.4 (137) Shipping Weight lbs. kg 11.0 5.2 15.0 6.8 MOLDED CASE 7 CIRCUIT BREAKERS 3VA63 400A Frame 4-Pole Electronic Trip Unit Continuous Ampere M-Interrupting Class (MJAE) Catalog Number 250 3VA6325-5HL41-0AA0 400 3VA6340-5HL41-0AA0 250 3VA6325-5HM41-0AA0 400 3VA6340-5HM41-0AA0 H-Interrupting Class (HJAE) Catalog Number 3VA6325-6HL41-0AA0 3VA6340-6HL41-0AA0 3VA6325-6HM41-0AA0 3VA6340-6HM41-0AA0 C-Interrupting Class (CJAE) Catalog Number ETU320 LI with dials 3VA6325-7HL41-0AA0 3VA6340-7HL41-0AA0 ETU330 LIG with dials 3VA6325-7HM41-0AA0 3VA6340-7HM41-0AA0 L-Interrupting Class (LJAE) Catalog Number 3VA6325-8HL41-0AA0 3VA6340-8HL41-0AA0 3VA6325-8HM41-0AA0 3VA6340-8HM41-0AA0 ETU350 LSI with dials 250 3VA6325-5HN41-0AA0 3VA6325-6HN41-0AA0 3VA6325-7HN41-0AA0 3VA6325-8HN41-0AA0 400 3VA6340-5HN41-0AA0 3VA6340-6HN41-0AA0 3VA6340-7HN41-0AA0 3VA6340-8HN41-0AA0 ETU550 LSI with LCD 250 3VA6325-5JP41-0AA0 3VA6325-6JP41-0AA0 3VA6325-7JP41-0AA0 3VA6325-8JP41-0AA0 400 3VA6340-5JP41-0AA0 3VA6340-6JP41-0AA0 3VA6340-7JP41-0AA0 3VA6340-8JP41-0AA0 ETU556 LSI(G Alarm) with LCD 250 3VA6325-5JT41-0AA0 3VA6325-6JT41-0AA0 3VA6325-7JT41-0AA0 3VA6325-8JT41-0AA0 400 3VA6340-5JT41-0AA0 3VA6340-6JT41-0AA0 3VA6340-7JT41-0AA0 3VA6340-8JT41-0AA0 ETU560 LSIG with LCD 250 3VA6325-5JQ41-0AA0 3VA6325-6JQ41-0AA0 3VA6325-7JQ41-0AA0 3VA6325-8JQ41-0AA0 400 3VA6340-5JQ41-0AA0 3VA6340-6JQ41-0AA0 3VA6340-7JQ41-0AA0 3VA6340-8JQ41-0AA0 ETU820 LI with LCD and Metering 250 3VA6325-5KL41-0AA0 3VA6325-6KL41-0AA0 3VA6325-7KL41-0AA0 3VA6325-8KL41-0AA0 400 3VA6340-5KL41-0AA0 3VA6340-6KL41-0AA0 3VA6340-7KL41-0AA0 3VA6340-8KL41-0AA0 ETU830 LIG with LCD and Metering 250 3VA6325-5KM41-0AA0 3VA6325-6KM41-0AA0 3VA6325-7KM41-0AA0 3VA6325-8KM41-0AA0 400 3VA6340-5KM41-0AA0 3VA6340-6KM41-0AA0 3VA6340-7KM41-0AA0 3VA6340-8KM41-0AA0 ETU850 LSI with LCD and Metering 250 3VA6325-5KP41-0AA0 3VA6325-6KP41-0AA0 3VA6325-7KP41-0AA0 3VA6325-8KP41-0AA0 400 3VA6340-5KP41-0AA0 3VA6340-6KP41-0AA0 3VA6340-7KP41-0AA0 3VA6340-8KP41-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 250 3VA6325-5KT41-0AA0 3VA6325-6KT41-0AA0 3VA6325-7KT41-0AA0 3VA6325-8KT41-0AA0 400 3VA6340-5KT41-0AA0 3VA6340-6KT41-0AA0 3VA6340-7KT41-0AA0 3VA6340-8KT41-0AA0 ETU860 LSIG with LCD and Metering 250 3VA6325-5KQ41-0AA0 3VA6325-6KQ41-0AA0 3VA6325-7KQ41-0AA0 3VA6325-8KQ41-0AA0 400 3VA6340-5KQ41-0AA0 3VA6340-6KQ41-0AA0 3VA6340-7KQ41-0AA0 3VA6340-8KQ41-0AA0 E-Interrupting Class (EJAE) Catalog Number 3VA6325-0HL31-0AA0 3VA6340-0HL31-0AA0 3VA6325-0HM31-0AA0 3VA6340-0HM31-0AA0 3VA6325-0HN31-0AA0 3VA6340-0HN31-0AA0 -- -- -- -- -- -- -- -- -- -- -- -- 3VA6325-0KT31-0AA0 3VA6340-0KT31-0AA0 3VA6325-0KQ31-0AA0 3VA6340-0KQ31-0AA0 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-69 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA63 400A Electronic Trip Circuit Breakers Technical information Connections for 75C wire for 3VA53 and 3VA63 Type Steel wrap around (Cu cable only) single cable lugsa Steel wrap around (Cu cable only) single cable lugs with control wire tap Aluminum body lug (Cu/Al cable) single cable lugsae Aluminum body lug with control wire tap (Cu/Al cable) single cable lugsa Aluminum body lug, 2 cables (Cu/Al cable) with 1 extended terminal cover Aluminum body lug, 2 cables (Cu/Al cable) with control wire tap and 1 extended terminal cover Distribution lug, 6 Cables (Cu/Al cable) with 1 extended terminal covera Copper body lug (Cu cable only) single cable lugsa Copper body lug (Cu cable only) with control wire tap single cable lugsa Copper body lug, 2 cables (Cu cable only) with 1 extended terminal covera Copper body lug, 2 cables (Cu cable only) with control wire tap and 1 extended terminal covera a Meets requirements for 100% rated breakers up to 250A. e Standard lug installed at the factory when breaker ordered with a "6" in the 12th position. Enclosures for 3VA53 and 3VA63 (3-pole only) NEMA Type 1 Surface 1 Flush 3R 12 4X (304) 4X (316) Neutral 200% Neutral Catalog Number 3VAE6001S 3VAE6001F 3VAE6003R 3VAE60012 3VAE6004X 3VAE6004X316 HN656ACB HN678ACB Minimum cable size 1/0 1/0 AWG 1 AWG 1 Maximum cable size 500 kcmil 500 kcmil 600 kcmil 600 kcmil Part Number (kit of 3 lugs) 3VA9473-0JA13 3VA9473-0JH13 3VA9373-0JB13 3VA9373-0JG13 2/0 600 kcmil 3VA9473-0JJ23 2/0 600 kcmil 3VA9473-0JC23 AWG 14 AWG 1 AWG 1 AWG 2 600 kcmil 600 kcmil 3VA9373-0JF60 3VA9373-0JD13 3VA9373-0JK13 2/0 600 kcmil 3VA9473-0JE23 3VA UL Molded Case Circuit Breakers 2/0 Accessories an6d0S0pkacrme Pilarts 3VA9473-0JL23 Internal accessories Internal accessories Optional equipment 3VA5 & 3VA6 400/600 A 3-pole Part Number (kit of 4 lugs) 3VA9474-0JA13 3VA9474-0JH13 3VA9374-0JB13 3VA9374-0JG13 3VA9474-0JJ23 3VA9474-0JC23 3VA9374-0JF60 3VA9374-0JD13 3VA9374-0JK13 3VA9474-0JE23 3VA9474-0JL23 3VA5 & 3VA6 400/600 A 4-pole Auxiliary switch Auxiliary switch Leading changeover switch Alarm switch Trip alarm switch Electrical alarm switch Auxiliary release Shunt trip flexible Slot No.: Type AUX_HQ AUX_HQ_el AUX_HP LCS_HQ LCS_HQ_el LCS_HP Type TAS_HQ TAS_HQ_el TAS_HP EAS_HQ EAS_HQ_el Type STF 600 A 600 A 25 24 23 22 21 11 12 13 14 15 35 34 33 32 31 25 24 23 22 21 11 12 13 14 15 xxxxx xxxxx xx xx xxxxx xxxxx xx xx x x x xxxxx xxxxx xx xx xxxxx xxxxx xx xx xxxxx xxxxx xx xx x x x xx xx xx xx x x x x xx xx xx xx x x x x x x x x Trip Settings for 3VA63 ETU320-LI, ETU330-LIG, ETU350-LSI Continuous Amperage LI, LIG, LSI In (Amp) Ir(Amp) (L) tld (sec) (L) Ii (Amp) (I)c 250 100 - 250 0.5 - 17 375-3000 400 150 - 400 0.5 - 17 600-4000 c Ii for ETU350 is fixed at the maximum level shown in table. Shunt trip left Undervoltage release 4 Universal release ETU/communication Communication module Breaker data server 24 V module Other Cylinder lock (type Ronis) LSI Isd= xIr (Amp) (S) 1.5 - 10 1.5 - 10 tsd (sec) (S) 0.08 - 0.4 STL UVR UNI Type COM060 LIG Ig (Amp) (G) 50 - 250 80 - 400 x x x x x x LI, LIG, LSI 4P only IN=xIr (Amp) 0.5 - 1 / OFF 0.5 - 1 / OFF x x x x x x I201_19495 b These accessories are for electronic trip breakers only. See page 7-83 for internal accessory part numbers. ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG Continuous Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G) LSI 3P with External CT LI, LIG, LSI, LSIG, LSI(G) 4P only In (Amp) Ir(Amp) (L)d tld (sec) (L) Ii (Amp) (I) Isd (Amp) (S) tsd (sec) (S) Ig (Amp) (G) tg (G) IN=xIr (Amp) IN (Amp) 250 100 - 250 0.5 - 25 375-3000 150 - 2500 50 - 250 50 - 400 / OFF 50 - 400 / OFF 0.05 - 0.5 0.05 - 0.8 400 150 - 400 0.5 - 17 600-4000 240 - 4000 80 - 400 80 - 640 / OFF 80 - 400 / OFF d Adjustable in steps of 1A. 4/6 Siemens · 04/2017 For specific trip settings refer to the Electronic Trip Unit section of the 3VA Systems Manual, which can be found in the document download center at https://digitalcontentcenter.compas.siemens-info.com/SIE_IM_3VA6_Systems_Manual.pdf MOLDED CASE 7 CIRCUIT BREAKERS 7-70 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers Revised on 06/30/21 3VA54 600A Thermal-magnetic Trip Circuit Breakers 3VA54 600A, 2-Pole in 3-Pole Frame, Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MLAS) Catalog Number H-Interrupting Class (HLAS) Catalog Number C-Interrupting Class (CLAS) Catalog Number TM230 FTAM 450 3VA5445-5EC61-0AA0 3VA5445-6EC61-0AA0 3VA5445-7EC61-0AA0 500 3VA5450-5EC61-0AA0 3VA5450-6EC61-0AA0 3VA5450-7EC61-0AA0 600 3VA5460-5EC61-0AA0 3VA5460-6EC61-0AA0 3VA5460-7EC61-0AA0 3VA54 600A Frame, 3-Pole Frame, Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MLAS) Catalog Number H-Interrupting Class (HLAS) Catalog Number C-Interrupting Class (CLAS) Catalog Number TM230 FTAMa 450 3VA5445-5EC31-0AA0 3VA5445-6EC31-0AA0 3VA5445-7EC31-0AA0 500 3VA5450-5EC31-0AA0 3VA5450-6EC31-0AA0 3VA5450-7EC31-0AA0 600 3VA5460-5EC31-0AA0 3VA5460-6EC31-0AA0 3VA5460-7EC31-0AA0 TM240 ATAM 450 3VA5445-5EF31-0AA0 3VA5445-6EF31-0AA0 3VA5445-7EF31-0AA0 500 3VA5450-5EF31-0AA0 3VA5450-6EF31-0AA0 3VA5450-7EF31-0AA0 600 3VA5460-5EF31-0AA0 3VA5460-6EF31-0AA0 3VA5460-7EF31-0AA0 3VA54 600A Frame, 4-Pole Frame, Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MLAS) Catalog Number H-Interrupting Class (HLAS) Catalog Number C-Interrupting Class (CLAS) Catalog Number TM230 FTAM Unprotected Neutral 450 3VA5445-5EC41-0AA0 3VA5445-6EC41-0AA0 3VA5445-7EC41-0AA0 500 3VA5450-5EC41-0AA0 3VA5450-6EC41-0AA0 3VA5450-7EC41-0AA0 600 3VA5460-5EC41-0AA0 3VA5460-6EC41-0AA0 3VA5460-7EC41-0AA0 TM240 ATAM Unprotected Neutral 450 3VA5445-5EF41-0AA0 3VA5445-6EF41-0AA0 3VA5445-7EF41-0AA0 500 3VA5450-5EF41-0AA0 3VA5450-6EF41-0AA0 3VA5450-7EF41-0AA0 600 3VA5460-5EF41-0AA0 3VA5460-6EF41-0AA0 3VA5460-7EF41-0AA0 TM230 FTAM 100% Neutral 450 3VA5445-5GC41-0AA0 3VA5445-6GC41-0AA0 3VA5445-7GC41-0AA0 500 3VA5450-5GC41-0AA0 3VA5450-6GC41-0AA0 3VA5450-7GC41-0AA0 600 3VA5460-5GC41-0AA0 3VA5460-6GC41-0AA0 3VA5460-7GC41-0AA0 TM240 ATAM 100% Neutral 450 3VA5445-5GF41-0AA0 3VA5445-6GF41-0AA0 3VA5445-7GF41-0AA0 500 3VA5450-5GF41-0AA0 3VA5450-6GF41-0AA0 3VA5450-7GF41-0AA0 600 3VA5460-5GF41-0AA0 3VA5460-6GF41-0AA0 3VA5460-7GF41-0AA0 Dimensions Breaker 3VA54 3VA54 Poles 3 4 W in. (mm) 5.4 (137) 7.2 (183) H in. (mm) 9.8 (249) 9.8 (249) D in. (mm) 5.4 (137) 5.4 (137) Shipping Weight lbs. kg 11.5 5.2 15.0 6.8 Interrupting Ratings for 3VA54 RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) Volts DC Interrupting Breaker 480Y/ 600Y/ 250 600 750 750 1000 Class Type 240 277V 480 347V 600 (2P) (3P) (3P) (4P) (4P) M MLAS 85 35 35 18 18 50 50 10 50 10 H HLAS 100 65 65 25 25 85 85 10 85 10 C CLAS 200 100 100 35 35 100 100 10 100 10 Trip Settings for 3VA54 TM230 - FTAM In (A) Ir(A) Ii (A) 450 450 2250 2700 3150 3600 4050 4500 500 500 2500 3000 3500 4000 4500 5000 600 600 3000 3600 4200 4800 5400 6000 TM240 - ATAM Ir(A) Ir(A) In (A) 90% 80% Ii (A) 450 405 360 2250 2700 3150 3600 4050 4500 500 450 400 2500 3000 3500 4000 4500 5000 600 540 480 3000 3600 4200 4800 5400 6000 a Available with NAVAL/50C ratings. Selection 3VA54 600A 3-Pole 3VA54 600A 4-Pole Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers without lugs. For factory installed nut keepers (3VA94730QA00), change the 12th digit of the catalog number to "2" (required to install a breaker in a panelboard or switchboard that has a provision). (For example, a 35KA @480VAC, 600A, 3-pole, 3VA54 with nut keepers would be catalog number 3VA5460-5EC32-0AA0). For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 600A, 3-pole, 3VA54 with lugs would be catalog number 3VA5460-5EC36-0AA0). Alternate connectors can be ordered separately for field installation. For NAVAL-rated thermal-magnetic trip circuit breakers, change the 13th digit of the catalog number to the number "1". (For example, a 35KA @480VAC, 600A, 3-pole, NAVAL rated 3VA54 would be catalog number 3VA5460-5EC31-1AA0) All 3VA54 thermal-magnetic trip circuit breakers are UL listed for reverse feed applications. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-71 MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA64 600A Electronic Trip Circuit Breakers Selection 3VA64 600A 3-Pole Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers without lugs. For factory installed nut keepers (3VA94730QA00), change the 12th digit of the catalog number to "2" (required to install a breaker in a panelboard or switchboard that has a provision). (For example, a 35KA @480VAC, 600A, 3-pole, 3VA64 with nut keepers would be catalog number 3VA6460-5HL32-0AA0). For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 600A, 3-pole, 3VA64 with lugs would be catalog number 3VA64605HL36-0AA0). Alternate connectors can be ordered separately for field installation. 3VA64 electronic trip circuit breakers are available with 100% ratings (up to 400A only in this frame 600A with 100% ratings can be purchased in the 800A frame). For 100% rated electronic trip circuit breakers, change the 13th digit of the catalog number to the number "2". (For example, a 35KA @480VAC, 400A, 3-pole, 100% rated 3VA64 would be catalog number 3VA6440-5HL31-2AA0). Requires the use of rated lugs -- see lug table below. All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked "Naval", and are suitable for use at 50C. All 3VA64 electronic trip circuit breakers are UL listed for reverse feed applications. 3VA64 600A Frame 3-Pole Electronic Trip Unit Continuous Ampere M-Interrupting Class (MLAE) Catalog Number 400 3VA6440-5HL31-0AA0 600 3VA6460-5HL31-0AA0 400 3VA6440-5HM31-0AA0 600 3VA6460-5HM31-0AA0 400 3VA6440-5HN31-0AA0 600 3VA6460-5HN31-0AA0 400 3VA6440-5JP31-0AA0 600 3VA6460-5JP31-0AA0 400 3VA6440-5JT31-0AA0 600 3VA6460-5JT31-0AA0 400 3VA6440-5JQ31-0AA0 600 3VA6460-5JQ31-0AA0 400 3VA6440-5KL31-0AA0 600 3VA6460-5KL31-0AA0 400 3VA6440-5KM31-0AA0 600 3VA6460-5KM31-0AA0 400 3VA6440-5KP31-0AA0 600 3VA6460-5KP31-0AA0 400 3VA6440-5KT31-0AA0 600 3VA6460-5KT31-0AA0 400 3VA6440-5KQ31-0AA0 600 3VA6460-5KQ31-0AA0 H-Interrupting Class (HLAE) C-Interrupting Class (CLAE) L-Interrupting Class (LLAE) Catalog Number Catalog Number Catalog Number ETU320 LI with dials 3VA6440-6HL31-0AA0 3VA6440-7HL31-0AA0 3VA6440-8HL31-0AA0 3VA6460-6HL31-0AA0 3VA6460-7HL31-0AA0 3VA6460-8HL31-0AA0 ETU330 LIG with dials 3VA6440-6HM31-0AA0 3VA6440-7HM31-0AA0 3VA6440-8HM31-0AA0 3VA6460-6HM31-0AA0 3VA6460-7HM31-0AA0 3VA6460-8HM31-0AA0 ETU350 LSI with dials 3VA6440-6HN31-0AA0 3VA6440-7HN31-0AA0 3VA6440-8HN31-0AA0 3VA6460-6HN31-0AA0 3VA6460-7HN31-0AA0 3VA6460-8HN31-0AA0 ETU550 LSI with LCD 3VA6440-6JP31-0AA0 3VA6440-7JP31-0AA0 3VA6440-8JP31-0AA0 3VA6460-6JP31-0AA0 3VA6460-7JP31-0AA0 3VA6460-8JP31-0AA0 ETU556 LSI(G Alarm) with LCD 3VA6440-6JT31-0AA0 3VA6440-7JT31-0AA0 3VA6440-8JT31-0AA0 3VA6460-6JT31-0AA0 3VA6460-7JT31-0AA0 3VA6460-8JT31-0AA0 ETU560 LSIG with LCD 3VA6440-6JQ31-0AA0 3VA6440-7JQ31-0AA0 3VA6440-8JQ31-0AA0 3VA6460-6JQ31-0AA0 3VA6460-7JQ31-0AA0 3VA6460-8JQ31-0AA0 ETU820 LI with LCD and Metering 3VA6440-6KL31-0AA0 3VA6440-7KL31-0AA0 3VA6440-8KL31-0AA0 3VA6460-6KL31-0AA0 3VA6460-7KL31-0AA0 3VA6460-8KL31-0AA0 ETU830 LIG with LCD and Metering 3VA6440-6KM31-0AA0 3VA6440-7KM31-0AA0 3VA6440-8KM31-0AA0 3VA6460-6KM31-0AA0 3VA6460-7KM31-0AA0 3VA6460-8KM31-0AA0 ETU850 LSI with LCD and Metering 3VA6440-6KP31-0AA0 3VA6440-7KP31-0AA0 3VA6440-8KP31-0AA0 3VA6460-6KP31-0AA0 3VA6460-7KP31-0AA0 3VA6460-8KP31-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 3VA6440-6KT31-0AA0 3VA6440-7KT31-0AA0 3VA6440-8KT31-0AA0 3VA6460-6KT31-0AA0 3VA6460-7KT31-0AA0 3VA6460-8KT31-0AA0 ETU860 LSIG with LCD and Metering 3VA6440-6KQ31-0AA0 3VA6440-7KQ31-0AA0 3VA6440-8KQ31-0AA0 3VA6460-6KQ31-0AA0 3VA6460-7KQ31-0AA0 3VA6460-8KQ31-0AA0 E-Interrupting Class (ELAE) Catalog Number -- 3VA6460-0HL31-0AA0 -- 3VA6460-0HM31-0AA0 -- 3VA6460-0HN31-0AA0 -- -- -- -- -- -- -- -- -- -- -- -- -- 3VA6460-0KT31-0AA0 -- 3VA6460-0KQ31-0AA0 MOLDED CASE 7 CIRCUIT BREAKERS 7-72 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA64 600A Electronic Trip Circuit Breakers Revised on 06/30/21 Selection Interrupting Ratings for 3VA64 Interrupting Class M H C L E Breaker Type MLAE HLAE CLAE LLAE ELAE RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240 480Y/277V 480 100 35 35 100 65 65 200 100 100 200 150 150 -- 200 200 600Y/347V 18 22 35 50 100 600 18 22 35 50 100 3VA64 600A 4-Pole Dimensions Breaker 3VA64 3VA64 Poles 3 4 W in. (mm) 5.4 (137) 7.2 (183) H in. (mm) 9.8 (249) 9.8 (249) D in. (mm) 5.4 (137) 5.4 (137) Shipping Weight lbs. kg 11.0 5.2 15.0 6.8 MOLDED CASE 7 CIRCUIT BREAKERS 3VA64 600A Frame 4-Pole Electronic Trip Unit Continuous Ampere M-Interrupting Class (MLAE) Catalog Number H-Interrupting Class (HLAE) Catalog Number C-Interrupting Class (CLAE) Catalog Number L-Interrupting Class (LLAE) Catalog Number ETU320 LI with dials 400 3VA6440-5HL41-0AA0 3VA6440-6HL41-0AA0 3VA6440-7HL41-0AA0 3VA6440-8HL41-0AA0 600 3VA6460-5HL41-0AA0 3VA6460-6HL41-0AA0 3VA6460-7HL41-0AA0 3VA6460-8HL41-0AA0 ETU330 LIG with dials 400 3VA6440-5HM41-0AA0 3VA6440-6HM41-0AA0 3VA6440-7HM41-0AA0 3VA6440-8HM41-0AA0 600 3VA6460-5HM41-0AA0 3VA6460-6HM41-0AA0 3VA6460-7HM41-0AA0 3VA6460-8HM41-0AA0 ETU350 LSI with dials 400 3VA6440-5HN41-0AA0 3VA6440-6HN41-0AA0 3VA6440-7HN41-0AA0 3VA6440-8HN41-0AA0 600 3VA6460-5HN41-0AA0 3VA6460-6HN41-0AA0 3VA6460-7HN41-0AA0 3VA6460-8HN41-0AA0 ETU550 LSI with LCD 400 3VA6440-5JP41-0AA0 3VA6440-6JP41-0AA0 3VA6440-7JP41-0AA0 3VA6440-8JP41-0AA0 600 3VA6460-5JP41-0AA0 3VA6460-6JP41-0AA0 3VA6460-7JP41-0AA0 3VA6460-8JP41-0AA0 ETU556 LSI(G Alarm) with LCD 400 3VA6440-5JT41-0AA0 3VA6440-6JT41-0AA0 3VA6440-7JT41-0AA0 3VA6440-8JT41-0AA0 600 3VA6460-5JT41-0AA0 3VA6460-6JT41-0AA0 3VA6460-7JT41-0AA0 3VA6460-8JT41-0AA0 ETU560 LSIG with LCD 400 3VA6440-5JQ41-0AA0 3VA6440-6JQ41-0AA0 3VA6440-7JQ41-0AA0 3VA6440-8JQ41-0AA0 600 3VA6460-5JQ41-0AA0 3VA6460-6JQ41-0AA0 3VA6460-7JQ41-0AA0 3VA6460-8JQ41-0AA0 ETU820 LI with LCD and Metering 400 3VA6440-5KL41-0AA0 3VA6440-6KL41-0AA0 3VA6440-7KL41-0AA0 3VA6440-8KL41-0AA0 600 3VA6460-5KL41-0AA0 3VA6460-6KL41-0AA0 3VA6460-7KL41-0AA0 3VA6460-8KL41-0AA0 ETU830 LIG with LCD and Metering 400 3VA6440-5KM41-0AA0 3VA6440-6KM41-0AA0 3VA6440-7KM41-0AA0 3VA6440-8KM41-0AA0 600 3VA6460-5KM41-0AA0 3VA6460-6KM41-0AA0 3VA6460-7KM41-0AA0 3VA6460-8KM41-0AA0 ETU850 LSI with LCD and Metering 400 3VA6440-5KP41-0AA0 3VA6440-6KP41-0AA0 3VA6440-7KP41-0AA0 3VA6440-8KP41-0AA0 600 3VA6460-5KP41-0AA0 3VA6460-6KP41-0AA0 3VA6460-7KP41-0AA0 3VA6460-8KP41-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 400 3VA6440-5KT41-0AA0 3VA6440-6KT41-0AA0 3VA6440-7KT41-0AA0 3VA6440-8KT41-0AA0 600 3VA6460-5KT41-0AA0 3VA6460-6KT41-0AA0 3VA6460-7KT41-0AA0 3VA6460-8KT41-0AA0 ETU860 LSIG with LCD and Metering 400 3VA6440-5KQ41-0AA0 3VA6440-6KQ41-0AA0 3VA6440-7KQ41-0AA0 3VA6440-8KQ41-0AA0 600 3VA6460-5KQ41-0AA0 3VA6460-6KQ41-0AA0 3VA6460-7KQ41-0AA0 3VA6460-8KQ41-0AA0 E-Interrupting Class (ELAE) Catalog Number -- 3VA6460-0HL41-0AA0 -- 3VA6460-0HM41-0AA0 -- 3VA6460-0HN41-0AA0 -- -- -- -- -- -- -- -- -- -- -- -- -- 3VA6460-0KT41-0AA0 -- 3VA6460-0KQ41-0AA0 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-73 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA64 600A Electronic Trip Circuit Breakers Technical information Connections for 75C wire for 3VA54 and 3VA64 Type Minimum cable size Maximum cable size Part Number (kit of 3 lugs) Part Number (kit of 4 lugs) Steel Wrap around (Cu cable only) single cable lugs Steel Wrap around (Cu cable only) single cable lugs with control wire tap Aluminum Body Lug (Cu/Al cable) single cable lugs Aluminum body lug with control wire tap (Cu/Al cable) single cable lugs Aluminum body lug, 2 cables (Cu/Al cable) with 1 extended terminal coverf Aluminum body lug, 2 cables (Cu/Al cable) with control wire tap and 1 extended terminal cover Distribution lug, 6 Cables (Cu/Al cable) with 1 extended terminal cover Copper body lug (Cu cable only) single cable lugsag Copper body lug (Cu cable only) with control wire tap single cable lugsa Copper body lug, 2 cables (Cu cable only) with 1 extended terminal coverb Copper body lug, 2 cables (Cu cable only) with control wire tap and 1 extended terminal coverb a Meets the requirement for 100% rated breakers up to 400A. b Meets requirement for 100% rated breakers up to 400A, requires the use of 90 degree wire. f Standard lug installed at the factory when breaker ordered with a "6" in the 12th position. g Standard lug installed at the factory on 400A 100% rated breaker when ordered with a "6" in the 12th position. Enclosures for 3VA54 and 3VA64 (3-pole only) NEMA Type 1 Surface 1 Flush 3R 12 4X (304) 4X (316) Catalog Number 3VAE6001S 3VAE6001F 3VAE6003R 3VAE60012 3VAE6004X 3VAE6004X316 1/0 1/0 AWG 1 AWG 1 500 kcmil 500 kcmil 600 kcmil 600 kcmil 3VA9473-0JA13 3VA9473-0JH13 3VA9373-0JB13 3VA9373-0JG13 2/0 600 kcmil 3VA9473-0JJ23 2/0 600 kcmil 3VA9473-0JC23 AWG 14 AWG 1 AWG 1 AWG 2 600 kcmil 600 kcmil 3VA9373-0JF60 3VA9373-0JD13 3VA9373-0JK13 2/30VA UL Molded Cas6e0C0irkccumitiBl reakers 3VA9473-0JE23 Accessories and Spare Parts 2/0 600 kcmil 3VA9473-0JL23 Internal accessories Internal accessories Optional equipment 3VA5 & 3VA6 400/600 A 3-pole 3VA9474-0JA13 3VA9474-0JH13 3VA9374-0JB13 3VA9374-0JG13 3VA9474-0JJ23 3VA9474-0JC23 3VA9374-0JF60 3VA9374-0JD13 3VA9374-0JK13 3VA9474-0JE23 3VA9474-0JL23 3VA5 & 3VA6 400/600 A 4-pole Auxiliary switch Auxiliary switch Leading changeover switch Alarm switch Trip alarm switch Electrical alarm switch Auxiliary release Shunt trip flexible Slot No.: Type AUX_HQ AUX_HQ_el AUX_HP LCS_HQ LCS_HQ_el LCS_HP Type TAS_HQ TAS_HQ_el TAS_HP EAS_HQ EAS_HQ_el Type 600 A 600 A 25 24 23 22 21 11 12 13 14 15 35 34 33 32 31 25 24 23 22 21 11 12 13 14 15 xxxxx xxxxx xx xx xxxxx xxxxx xx xx x x x xxxxx xxxxx xx xx xxxxx xxxxx xx xx xxxxx xxxxx xx xx x x x xx xx xx xx x x x x xx xx xx xx x x x x STF x x x x Neutral 200% Neutral HN656ACB HN678ACB Trip Settings for 3VA64 ETU320-LI, ETU330-LIG, ETU350-LSI Shunt trip left STL 4 Undervoltage release Universal release ETU/communication UVR UNI Type Communication module Breaker data server COM060 24 V module Other Cylinder lock (type Ronis) x x x x x x x x x x x x I201_19495 Continuous Amperage LI, LIG, LSI LI, LIG, LSI c These accessories are for LSI LIG 4P only electronic trip breakers only. In (Amp) 400 600 Ir(Amp) (L) 150 - 400 250 - 600 tld (sec) (L) 0.5 - 17 0.5 - 15 Ii (Amp) (I)d 600-4800 900-5400 Isd= xIr (Amp) (S) 1.5 - 10 1.5 - 9 tsd (sec) (S) 0.08 - 0.4 Ig (Amp) (G) 80 - 400 120 - 600 IN=xIr (Amp) 0.5 - 1 / OFF 0.5 - 1 / OFF See page 7-83 for internal accessory part numbers. d Ii for ETU350 is fixed at the maximum level shown in table. ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU830-LIG, ETU850-LSI, ETU856 LSI(A), ETU860-LSIG Continuous Amperage LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G) LSI 3P with External CT LI, LIG, LSI, LSIG, LSI(G) 4P only In (Amp) Ir(Amp) (L)e tld (sec) (L) Ii (Amp) (I) Isd (Amp) (S) tsd (sec) (S) Ig (Amp) (G) tg (G) IN=xIr (Amp) IN (Amp) 400 150 - 400 0.5 - 25 600-4800 240 - 4000 80 - 400 80 - 640 / OFF 80 - 600 / OFF 600 250 - 600 0.5 - 15 900-5400 360 - 5400 0.05 - 0.5 120 - 600 0.05 - 0.8 120 - 960 / OFF 120 - 600 / OFF e Adjustable in steps of 1A. For specific trip settings refer to the Electronic Trip Unit section o4f/6the 3SVieAmeSnsy·s0t4e/2m017s Manual, which can be found in the document download center at https://digitalcontentcenter.compas.siemens-info.com/SIE_IM_3VA6_Systems_Manual.pdf 7-74 Siemens Industry, Inc. SPEEDFAXTM Product Catalog MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers 3VA55 800A Thermal-Magnetic Trip Circuit Breakers Revised on 04/30/21 Selection 3VA55 800A, 2-pole in 3-pole Frame, Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MMAS) Catalog Number H-Interrupting Class (HMAS) Catalog Number C-Interrupting Class (CMAS) Catalog Number TM230 FTAM 600 3VA5560-5EC62-0AA0 3VA5560-6EC62-0AA0 3VA5560-7EC62-0AA0 700 3VA5570-5EC62-0AA0 3VA5570-6EC62-0AA0 3VA5570-7EC62-0AA0 800 3VA5580-5EC62-0AA0 3VA5580-6EC62-0AA0 3VA5580-7EC62-0AA0 3VA55 800A, 3-pole Frame, Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MMAS) Catalog Number H-Interrupting Class (HMAS) Catalog Number C-Interrupting Class (CMAS) Catalog Number TM230 FTAM 600 3VA5560-5EC32-0AA0 3VA5560-6EC32-0AA0 3VA5560-7EC32-0AA0 700 3VA5570-5EC32-0AA0 3VA5570-6EC32-0AA0 3VA5570-7EC32-0AA0 800 3VA5580-5EC32-0AA0 3VA5580-6EC32-0AA0 3VA5580-7EC32-0AA0 3VA55 800A 3-Pole 3VA55 800A, 4-pole Frame, Thermal-Magnetic Trip Unit Cont. Ampere Rating M-Interrupting Class (MMAS) Catalog Number H-Interrupting Class (HMAS) Catalog Number C-Interrupting Class (CMAS) Catalog Number TM230 FTAM Unprotected Neutral 600 3VA5560-5EC42-0AA0 3VA5560-6EC42-0AA0 3VA5560-7EC42-0AA0 700 3VA5570-5EC42-0AA0 3VA5570-6EC42-0AA0 3VA5570-7EC42-0AA0 800 3VA5580-5EC42-0AA0 3VA5580-6EC42-0AA0 3VA5580-7EC42-0AA0 TM230 FTAM 100% Neutral 600 3VA5560-5GC42-0AA0 3VA5560-6GC42-0AA0 3VA5560-7GC42-0AA0 700 3VA5570-5GC42-0AA0 3VA5570-6GC42-0AA0 3VA5570-7GC42-0AA0 800 3VA5580-5GC42-0AA0 3VA5580-6GC42-0AA0 3VA5580-7GC42-0AA0 Dimensions Breaker 3VA55 3VA55 3VA55 Poles 2(3) 3 4 W in. (mm) 8.3 (210) 8.3 (210) 11.1 (280) H in. (mm) 12.5 (318) 12.5 (318) 12.5 (318) D in. (mm) 5.8 (147) 5.8 (147) 5.8 (147) Shipping Weight lbs. kg 29.3 13.3 29.4 13.4 37.4 17.0 Interrupting Ratings for 3VA55 RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) Volts DC Interrupting Breaker 480Y/ 600Y/ 250 600 750 750 1000 Class Type 240 277V 480 347V 600 (2P) (3P) (3P) (4P) (4P) M MMAS 85 35 35 18 18 50 50 50 50 18 H HMAS 100 65 65 25 25 85 85 85 85 25 C CMAS 200 100 100 50 50 100 100 100 100 50 Trip Settings for 3VA55 TM230 - FTAM In (Amp) 600 700 800 Ir(Amp) 600 700 800 Ii (Amp) 3000 3600 3500 4200 4000 4800 TM240 - ATAM In (Amp) 600 700 800 Ir(Amp) 90% 540 630 720 Ir(Amp) 80% 480 560 640 Ii (Amp) 3000 3600 3500 4200 4000 4800 4200 4900 5600 4200 4900 5600 4800 5600 6400 4800 5600 6400 5400 6300 7200 5400 6300 7200 6000 7000 8000 6000 7000 8000 3VA55 800A 4-Pole Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers with nutkeepers on both line and load ends.. For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 800A, 3-pole, 3VA55 with lugs would be catalog number 3VA5580-5EC36-0AA0). Alternate connectors can be ordered separately for field installation. For NAVAL-rated (3-pole only) thermal-magnetic trip circuit breakers, change the 13th digit of the catalog number to the number "1". (For example, a 35KA @480VAC, 800A, 3-pole, NAVAL rated 3VA55 would be catalog number 3VA5580-5EC321AA0) All 3VA55 thermal-magnetic trip circuit breakers are UL listed for reverse feed applications. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-75 MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers Revised on 06/30/21 3VA65 800A Electronic Trip Circuit Breakers Selection 3VA65 800A 3-Pole Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers with nutkeepers on both line and load ends. For factory installed standard line and load lugs, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 800A, 3-pole, 3VA65 with lugs would be catalog number 3VA6580-5HL36-0AA0). Alternate connectors can be ordered separately for field installation. 3VA65 electronic trip circuit breakers are available with 100% ratings. For 100% rated electronic trip circuit breakers, change the 13th digit of the catalog number to the number "2". (For example, a 35KA @480VAC, 600A, 3-pole, 100% rated 3VA65 would be catalog number 3VA6560-5HL32-2AA0). Requires the use of rated lugs -- see lug table below. All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked "Naval", and are suitable for use at 50C. All 3VA65 electronic trip circuit breakers are UL listed for reverse feed applications. 3VA65 800A, 3-pole Frame, Electronic Trip Unit Continuous Ampere M-Interrupting Class (MMAE) Catalog Number H-Interrupting Class (HMAE) Catalog Number C-Interrupting Class (CMAE) Catalog Number ETU320 LI with dials 600 3VA6560-5HL32-0AA0 3VA6560-6HL32-0AA0 3VA6560-7HL32-0AA0 800 3VA6580-5HL32-0AA0 3VA6580-6HL32-0AA0 3VA6580-7HL32-0AA0 ETU330 LIG with dials 600 3VA6560-5HM32-0AA0 3VA6560-6HM32-0AA0 3VA6560-7HM32-0AA0 800 3VA6580-5HM32-0AA0 3VA6580-6HM32-0AA0 3VA6580-7HM32-0AA0 ETU350 LSI with dials 600 3VA6560-5HN32-0AA0 3VA6560-6HN32-0AA0 3VA6560-7HN32-0AA0 800 3VA6580-5HN32-0AA0 3VA6580-6HN32-0AA0 3VA6580-7HN32-0AA0 ETU550 LSI with LCD 600 3VA6560-5JP32-0AA0 3VA6560-6JP32-0AA0 3VA6560-7JP32-0AA0 800 3VA6580-5JP32-0AA0 3VA6580-6JP32-0AA0 3VA6580-7JP32-0AA0 ETU556 LSI(G Alarm) with LCD 600 3VA6560-5JT32-0AA0 3VA6560-6JT32-0AA0 3VA6560-7JT32-0AA0 800 3VA6580-5JT32-0AA0 3VA6580-6JT32-0AA0 3VA6580-7JT32-0AA0 ETU560 LSIG with LCD 600 3VA6560-5JQ32-0AA0 3VA6560-6JQ32-0AA0 3VA6560-7JQ32-0AA0 800 3VA6580-5JQ32-0AA0 3VA6580-6JQ32-0AA0 3VA6580-7JQ32-0AA0 ETU820 LI with LCD and Metering 600 3VA6560-5KL32-0AA0 3VA6560-6KL32-0AA0 3VA6560-7KL32-0AA0 800 3VA6580-5KL32-0AA0 3VA6580-6KL32-0AA0 3VA6580-7KL32-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 600 3VA6560-5KT32-0AA0 3VA6560-6KT32-0AA0 3VA6560-7KT32-0AA0 800 3VA6580-5KT32-0AA0 3VA6580-6KT32-0AA0 3VA6580-7KT32-0AA0 ETU860 LSIG with LCD and Metering 600 3VA6560-5KQ32-0AA0 3VA6560-6KQ32-0AA0 3VA6560-7KQ32-0AA0 800 3VA6580-5KQ32-0AA0 3VA6580-6KQ32-0AA0 3VA6580-7KQ32-0AA0 Enclosures for 3VA55, 3VA65, 3VA66 (3-pole only) NEMA Type 1 Surface 1 Flush 3R 12 4X (304) 4X (316) Neutral 200% Neutral Catalog Number 3VAE8001S 3VAE8001F 3VAE8003R 3VAE80012 3VAE8004X 3VAE8004X316 HN656ACB HN678ACB MOLDED CASE 7 CIRCUIT BREAKERS 7-76 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA65 800A Electronic Trip Circuit Breakers Revised on 06/30/20 Selection Interrupting Ratings for 3VA65 Interrupting Class M H C Breaker Type MMAE HMAE CMAE RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240 480Y/277V 480 100 35 35 150 65 65 200 100 100 600Y/347V 25 35 50 600 25 35 50 3VA65 800A 4-Pole Dimensions Breaker 3VA65 3VA65 Poles 3 4 W in. (mm) 8.3 (210) 11.1 (280) H in. (mm) 12.5 (318) 12.5 (318) D in. (mm) 5.8 (147) 5.8 (147) Shipping Weight lbs. kg 29.4 13.4 37.4 17.0 3VA65 800A, 4-pole Frame, Electronic Trip Unit Continuous Ampere M-Interrupting Class (MMAE) Catalog Number H-Interrupting Class (HMAE) Catalog Number C-Interrupting Class (CMAE) Catalog Number ETU320 LI with dials 600 3VA6560-5HL42-0AA0 800 3VA6580-5HL42-0AA0 3VA6560-6HL42-0AA0 3VA6580-6HL42-0AA0 3VA6560-7HL42-0AA0 3VA6580-7HL42-0AA0 ETU330 LIG with dials 600 3VA6560-5HM42-0AA0 3VA6560-6HM42-0AA0 3VA6560-7HM42-0AA0 800 3VA6580-5HM42-0AA0 3VA6580-6HM42-0AA0 3VA6580-7HM42-0AA0 ETU350 LSI with dials 600 3VA6560-5HN42-0AA0 3VA6560-6HN42-0AA0 3VA6560-7HN42-0AA0 800 3VA6580-5HN42-0AA0 3VA6580-6HN42-0AA0 3VA6580-7HN42-0AA0 600 3VA6560-5JP42-0AA0 800 3VA6580-5JP42-0AA0 ETU550 LSI with LCD 3VA6560-6JP42-0AA0 3VA6580-6JP42-0AA0 3VA6560-7JP42-0AA0 3VA6580-7JP42-0AA0 ETU556 LSI(G Alarm) with LCD 600 3VA6560-5JT42-0AA0 3VA6560-6JT42-0AA0 3VA6560-7JT42-0AA0 800 3VA6580-5JT42-0AA0 3VA6580-6JT42-0AA0 3VA6580-7JT42-0AA0 ETU560 LSIG with LCD 600 3VA6560-5JQ42-0AA0 3VA6560-6JQ42-0AA0 3VA6560-7JQ42-0AA0 800 3VA6580-5JQ42-0AA0 3VA6580-6JQ42-0AA0 3VA6580-7JQ42-0AA0 ETU820 LI with LCD and Metering 600 3VA6560-5KL42-0AA0 800 3VA6580-5KL42-0AA0 3VA6560-6KL42-0AA0 3VA6580-6KL42-0AA0 3VA6560-7KL42-0AA0 3VA6580-7KL42-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 600 3VA6560-5KT42-0AA0 800 3VA6580-5KT42-0AA0 3VA6560-6KT42-0AA0 3VA6580-6KT42-0AA0 3VA6560-7KT42-0AA0 3VA6580-7KT42-0AA0 ETU860 LSIG with LCD and Metering 600 3VA6560-5KQ42-0AA0 3VA6560-6KQ42-0AA0 3VA6560-7KQ42-0AA0 800 3VA6580-5KQ42-0AA0 3VA6580-6KQ42-0AA0 3VA6580-7KQ42-0AA0 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-77 3VA Molded Case Circuit Breakers Revised on 06/30/21 3VA55 and 3VA65 800A / 3VA66 1000A Circuit Breakers Connections for 75C wire for 3VA55, 3VA65 and 3VA66 Type Aluminum body lug, 2 cables (Cu/Al cable)d Aluminum body lug, 2 cables (Cu/Al cable) with control wire tap Aluminum body lug, 2 cables (Cu/Al cable) with1 extended terminal covera Aluminum body lug, 2 cables (Cu/Al cable) with control wire tap and 1 extended terminal covera Aluminum body lug, 3 cables (Cu/Al cable) Aluminum body lug, 3 cables (Cu/Al cable) with control wire tap Aluminum body lug, 3 cables (Cu/Al cable) with 1 extended terminal covera Aluminum body lug, 3 cables (Cu/Al cable) with control wire tap and 1 extended terminal covera Aluminum body lug, 4 cables (Cu/Al cable) with 1 extended terminal coverae Aluminum body lug, 4 cables (Cu/Al cable) with control wire tap and 1 extended terminal covera Aluminum body lug, 4 cables (Cu/Al cable) with 1 extended terminal covera Aluminum body lug, 4 cables (Cu/Al cable) with control wire tap and 1 extended terminal covera Copper body lug, 3 cables (Cu/Al cable) with control wire tapa Copper body lug, 4 cables (Cu/Al cable) with control wire tap and 1 extended terminal cover Minimum cable size 4/0 4/0 400 kcmil 400 kcmil 4/0 4/0 500 kcmil 500 kcmil 4/0 4/0 4/0 4/0 4/0 4/0 a Meets requirements for 100% rated breakers up to 800A, requires the use of 90 degree wire. d Standard lug for the 600A and 700A 3VA55 and the 600A 3VA65 will be installed at the factory when the breaker is ordered with a "6" in the 12th position. e Standard lug for the 800A 3VA55/65 and the 1000A 3VA66 will ship with the breaker from the factory for field installation when the breaker is ordered with a "6" in the 12th position. Product not yet released. Technical information Maximum cable size 600 kcmil 600 kcmil 750 kcmil Part Number (kit of 3 lugs) 3VA9573-0JB23 3VA9573-0JG23 3VA9673-0JJ24 Part Number (kit of 4 lugs) 3VA9574-0JB23 3VA9574-0JG23 3VA9674-0JJ24 750 kcmil 3VA9673-0JC24 3VA9674-0JC24 400 kcmil 400 kcmil 750 kcmil 3VA9673-0JB32 3VA9673-0JG32 3VA9673-0JJ34 3VA9674-0JB32 3VA9674-0JG32 3VA9674-0JJ34 750 kcmil 3VA9673-0JC34 3VA9674-0JC34 500 kcmil 3VA9673-0JJ43 3VA9674-0JJ43 500 kcmil 3VA9673-0JC43 3VA9674-0JC43 600 kcmil 3VA9673-0JJ44 3VA9674-0JJ44 600 kcmil 3VA9673-0JC44 3VA9674-0JC44 400 kcmil 3VA9673-0JK32 3VA9674-0JK32 500 kcmil 3VA9673-0JL43 3VA UL Molded Case Circuit Breakers Accessories and Spare Parts Internal accessories Internal accessories Optional equipment 3VA9674-0JL43 3VA5 & 3VA6 800A & 1000A 3- & 4-pole 1250 A Auxiliary switch Slot No.: Type 24 23 22 21 11 12 13 14 15 16 AUX_HQ xx xx xx xx Trip Settings for 3VA55 Auxiliary switch AUX_HQ_el AUX_HP xx xx xx x xx xx xx xx TM230 - FTAM LCS_HQ x Leading changeover switch LCS_HQ_el x In (Amp) 600 700 Ir(Amp) 600 700 Ii (Amp) 3000 3600 3500 4200 4200 4900 4800 5600 5400 6300 6000 7000 Alarm switch Trip alarm switch LCS_HP Type TAS_HQ TAS_HQ_el x xx xx 800 800 4000 4800 5600 6400 7200 8000 Electrical alarm switch (3VA6) TAS_HP EAS_HQ EAS_HQ_el x x x Trip Settings for 3VA65 and 3VA66 ETU320-LI, ETU330-LIG, ETU350-LSI Electrical alarm switch Auxiliary release Shunt trip flexible 4 Shunt trip left SAS_HQ SAS_HQ_el Type STF x STL x STL (EI) Cont. LI, LIG, LSI Residual current release RCR Amp LI, LIG, LSI LSI LIG 4P only Undervoltage release UVR x Universal release UNI x tld (sec) Isd= xIr tsd (sec) Ig (Amp) IN=xIr ETU/communication Type In (Amp) Ir(Amp) (L) (L) Ii (Amp) (I) (Amp) (S) (S) (G) (Amp) Communication module 3VA server COM060 x 600 240 - 600 0.5 - 17 900 - 7200 1.5 - 12 0 - 0.4 120 - 600 0.2 - 1.0 24 V module x 800 1000 320 - 800 0.5 - 17 1200 - 8000 1.5 - 10 0 - 0.4 160 - 800 0.2 - 1.0 400 - 1000 0.5 - 17 1500 - 10000 1.5 - 10 0 - 0.4 200 - 1000 0.2 - 1.0 Other Cylinder lock (type Ronis) ETU550-LSI, ETU556 LSI(A), ETU560-LSIG, ETU820-LI, ETU856 LSI(A), ETU860-LSIG x b These accessories are for electronic trip breakers only. Cont. Amp LI, LIG, LSI, LSIG, LSI(G) LSI, LSIG, LSI(G) LIG, LSIG, LSI(G) LSI 3P with External CT LI, LIG, LSI, LSIG, LSI(G) 4P only In (Amp) Ir(Amp) (L)c tld (sec) (L) Ii (Amp) (I) Isd (Amp) (S) tsd (sec) (S) Ig (Amp) (G) tg (G) IN=xIr (Amp) IN (Amp) 600 240 - 600 0.5 - 25 900 - 7200 360 - 7200 0.05 - 0.5 120 - 600 0.05 - 0.8 120 - 960 120 - 600 800 320 - 800 0.5 - 25 1200 - 8000 480 - 8000 0.05 - 0.5 160 - 800 0.05 - 0.8 160 - 1280 160 - 800 1000 400 - 1000 0.5 - 25 1500 - 10000 600 - 10000 0.05 - 0.5 200 - 1000 0.05 - 0.8 200 - 1600 200 - 1000 c Adjustable in steps of 1A. For specific trip settings refer to the Electronic Trip Unit section of the 3VA Systems Manual, which can be found in the document download center at https://digitalcontentcenter.compas.siemens-info.com/SIE_IM_3VA6_Systems_Manual.pdf 7-78 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 4/6 Siemens · 04/2017 MOLDED CASE 7 CIRCUIT BREAKERS Internal Booster 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA66 1000A Electronic Trip Circuit Breakers Selection Ordering Information The catalog numbers listed here are for complete, non-interchangeable trip circuit breakers with nutkeepers on both line and load ends. To order installed standard line and load lugs which are shipped with the breaker for field installation, change the 12th digit to "6" (standard lugs are identified in the lug table and footnotes in this section of the SpeedFax). (For example, a 35KA @480VAC, 1000A, 3-pole, 3VA66 with lugs would be catalog number 3VA66105HL36-0AA0). Alternate connectors can be ordered separately for field installation. All 3VA6 circuit breakers are certified to UL 489 Supplement SB, are marked "Naval", and are suitable for use at 50C. All 3VA66 electronic trip circuit breakers are UL listed for reverse feed applications. 3VA66 1000A 3-Pole 3VA66 1000A, 3-pole Frame, Electronic Trip Unit Continuous Ampere M-Interrupting Class (MMNAE) Catalog Number H-Interrupting Class (HMNAE) Catalog Number C-Interrupting Class (CMNAE) Catalog Number ETU320 LI with dials 1000 3VA6610-5HL32-0AA0 3VA6610-6HL32-0AA0 3VA6610-7HL32-0AA0 ETU330 LIG with dials 1000 3VA6610-5HM32-0AA0 3VA6610-6HM32-0AA0 3VA6610-7HM32-0AA0 1000 3VA6610-5HN32-0AA0 ETU350 LSI with dials 3VA6610-6HN32-0AA0 ETU550 LSI with LCD 3VA6610-7HN32-0AA0 1000 3VA6610-5JP32-0AA0 3VA6610-6JP32-0AA0 3VA6610-7JP32-0AA0 ETU556 LSI(G Alarm) with LCD 1000 3VA6610-5JT32-0AA0 3VA6610-6JT32-0AA0 3VA6610-7JT32-0AA0 ETU560 LSIG with LCD 1000 3VA6610-5JQ32-0AA0 3VA6610-6JQ32-0AA0 3VA6610-7JQ32-0AA0 ETU820 LI with LCD and Metering 1000 3VA6610-5KL32-0AA0 3VA6610-6KL32-0AA0 3VA6610-7KL32-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 1000 3VA6610-5KT32-0AA0 3VA6610-6KT32-0AA0 3VA6610-7KT32-0AA0 ETU860 LSIG with LCD and Metering 1000 3VA6610-5KQ32-0AA0 3VA6610-6KQ32-0AA0 3VA6610-7KQ32-0AA0 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-79 3VA Molded Case Circuit Breakers 3VA66 1000A Electronic Trip Circuit Breakers Revised on 02/28/21 Selection 3VA66 1000A 4-Pole Interrupting Ratings for 3VA66 Interrupting Class M H C Breaker Type MMNAE HMNAE CMNAE RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240 480Y/277V 480 100 35 35 150 65 65 200 100 100 600Y/347V 25 35 50 600 25 35 50 Dimensions Breaker 3VA66 3VA66 Poles 3 4 W in. (mm) 8.3 (210) 11.1 (280) H in. (mm) 12.5 (318) 12.5 (318) D in. (mm) 5.8 (147) 5.8 (147) Shipping Weight lbs. kg 29.4 13.4 37.4 17.0 3VA66 1000A, 4-pole Frame, Electronic Trip Unit Continuous Ampere M-Interrupting Class (MMNAE) Catalog Number H-Interrupting Class (HMNAE) Catalog Number C-Interrupting Class (CMNAE) Catalog Number ETU320 LI with dials 1000 3VA6610-5HL42-0AA0 3VA6610-6HL42-0AA0 3VA6610-7HL42-0AA0 ETU330 LIG with dials 1000 3VA6610-5HM42-0AA0 3VA6610-6HM42-0AA0 3VA6610-7HM42-0AA0 ETU350 LSI with dials 1000 3VA6610-5HN42-0AA0 3VA6610-6HN42-0AA0 3VA6610-7HN42-0AA0 ETU550 LSI with LCD 1000 3VA6610-5JP42-0AA0 3VA6610-6JP42-0AA0 3VA6610-7JP42-0AA0 ETU556 LSI(G Alarm) with LCD 1000 3VA6610-5JT42-0AA0 3VA6610-6JT42-0AA0 3VA6610-7JT42-0AA0 ETU560 LSIG with LCD 1000 3VA6610-5JQ42-0AA0 3VA6610-6JQ42-0AA0 3VA6610-7JQ42-0AA0 ETU820 LI with LCD and Metering 1000 3VA6610-5KL42-0AA0 3VA6610-6KL42-0AA0 3VA6610-7KL42-0AA0 ETU856 LSI(G Alarm) with LCD and Metering 1000 3VA6610-5KT42-0AA0 3VA6610-6KT42-0AA0 3VA6610-7KT42-0AA0 ETU860 LSIG with LCD and Metering 1000 3VA6610-5KQ42-0AA0 3VA6610-6KQ42-0AA0 3VA6610-7KQ42-0AA0 MOLDED CASE 7 CIRCUIT BREAKERS 7-80 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA Molded Case Switch and Motor Circuit Protector Revised on 05/31/21 Selection Ordering Information Breaking capacity (the SCCR rating) is the maximum permissible short circuit current at the installation location of the MCS in combination with an appropriate overload protective device. For factory installed nut keepers for molded case switches and motor circuit protectors, change the 12th digit of the catalog number to "2" (required for panelboard or switchboard installation). For factory installed standard lugs, change the 12th digit to "6" (standard lugs are identified in the lug table in the accessory section of the SpeedFax). Alternate connection technology need to be ordered separately for field installation. Magnetic switch Electronic Trip Unit switch Molded Case Switch Magnetic Frame (Breaker Type) 3VA51 (HEAS) Max. Ampere Rating 100 2-Pole Catalog Number 3VA5110-1BB21-0AA0 3-Pole Catalog Number 3VA5110-1BB31-0AA0 Short-Circuit Current Rating (AC) 240V 480V 600V 150k 65k 25ka Short-Circuit Current Rating (DC) 125V 250Vb 500Vc 600Vc Instantaneous short circuit protection 30k 100k 100k -- 1600 A 3VA52 150 (HFAS) 250 3VA53 (HJAS) 400 3VA54 (HLAS) 600 3VA55 (HMAS) 800 Catalog Number 3VA5215-0BB61-0AA0 3VA5225-0BB61-0AA0 3VA5340-0BB61-0AA0 3VA5460-0BB61-0AA0 3VA5580-0BB62-0AA0 Catalog Number 3VA5215-0BB31-0AA0 3VA5225-0BB31-0AA0 3VA5340-0BB31-0AA0 3VA5460-0BB31-0AA0 3VA5580-0BB32-0AA0 240V 100k 100k 100k 100k 100k 480V 65k 65k 65k 65k 65k 600V 25k 25k 25k 25k 25k 250V 85k 85k 85k 85k 85k 500Vb 85k 85k 600Vc -- -- 750Vc 85k 85k 2400 A 2500 A 85k 85k 10k 6000 A 85k 85k 10k 6000 A 85k 85k 85k 8000 A Frame (Breaker Type) 3VA52 (CFAS) 3VA53 (CJAS) 3VA54 (CLAS) 3VA55 (CMAS) Max. Ampere Rating 100 150 250 400 600 800 2-Pole Catalog Number 3VA5210-1BB61-0AA0 3VA5215-1BB61-0AA0 3VA5225-1BB61-0AA0 3VA5340-1BB61-0AA0 3VA5460-1BB61-0AA0 3VA5580-1BB62-0AA0 3-Pole Catalog Number 3VA5210-1BB31-0AA0 3VA5215-1BB31-0AA0 3VA5225-1BB31-0AA0 3VA5340-1BB31-0AA0 3VA5460-1BB31-0AA0 3VA5580-1BB32-0AA0 Short-Circuit Current Rating (AC) 240V 480V 600V 200k 100k 35k 200k 100k 35k 200k 100k 35k 200k 100k 35k 200k 100k 35k 100k 100k 50k Short-Circuit Current Rating (DC) 250V 500Vb 600Vc 100k 100k -- 100k 100k -- 100k 100k -- 750Vc 100k 100k 100k Instantaneous short circuit protection 2500 A 2400 A 2500 A 100k 100k 100k 10k 6000 A 100k 100k 100k 10k 6000 A 100k 100k 100k 100k 8000 A Molded Case Switch Electronic Frame (Breaker Type) 3VA63 (CJAE) 3VA64 (CLAE) Max. Ampere Rating 400 600 2-Pole Catalog Number -- -- 3-Pole Catalog Number 3VA6340-1BB31-0AA0 3VA6460-1BB31-0AA0 Short-Circuit Current Rating 240V 480V 600V 200k 100k 35k 200k 100k 35k Instantaneous short circuit protection 5600 A 5400 A MOLDED CASE 7 CIRCUIT BREAKERS a Rated at 600 Y/347 V AC. b Two poles in series. c Three poles in series. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-81 3VA Molded Case Circuit Breakers Revised on 06/30/21 3VA Molded Case Switch and Motor Circuit Protector Motor circuit protector TM120M AMc Frame Maximum (Breaker Ampere 3-Pole Type) Rating Catalog Number Instantaneous short circuit protection 3VA51 1 (HEAP) 2 3 5 7 10 15 25 30 40 50 70 80 90 100 110 125 3VA52 150 (HFAP) 200 250 3VA53 250 (HJAP) 3VA5181-1MU31-0AA0 3VA5181-1MH31-0AA0 3VA5102-1MU31-0AA0 3VA5102-1MH31-0AA0 3VA5103-1MU31-0AA0 3VA5103-1MH31-0AA0 3VA5105-1MU31-0AA0 3VA5105-1MH31-0AA0 3VA5107-1MU31-0AA0 3VA5107-1MH31-0AA0 3VA5191-1MU31-0AA0 3VA5191-1MH31-0AA0 3VA5195-1MU31-0AA0 3VA5195-1MH31-0AA0 3VA5125-1MU31-0AA0 3VA5125-1MH31-0AA0 3VA5130-1MU31-0AA0 3VA5130-1MH31-0AA0 3VA5140-1MU31-0AA0 3VA5140-1MH31-0AA0 3VA5150-1MU31-0AA0 3VA5150-1MH31-0AA0 3VA5170-1MU31-0AA0 3VA5170-1MH31-0AA0 3VA5180-1MU31-0AA0 3VA5180-1MH31-0AA0 3VA5190-1MU31-0AA0 3VA5190-1MH31-0AA0 3VA5110-1MU31-0AA0 3VA5110-1MH31-0AA0 3VA5111-1MU31-0AA0 3VA5111-1MH31-0AA0 3VA5112-1MU31-0AA0 3VA5112-1MH31-0AA0 3VA5215-0MU31-0AA0 3VA5215-0MH31-0AA0 3VA5220-0MU31-0AA0 3VA5220-0MH31-0AA0 3VA5225-0MU31-0AA0 3VA5225-0MH31-0AA0 3VA5325-0MU31-0AA0 3VA5325-0MH31-0AA0 3 ... 7 5 ... 12 6 ... 14 10 ... 24 9 ... 21 15 ... 36 15 ... 35 25 ... 60 21 ... 49 35 ... 84 30 ... 70 50 ... 120 45 ... 105 75 ... 180 75 ... 175 125 ... 300 90 ... 210 150 ... 360 120 ... 280 200 ... 480 150 ... 350 250 ... 600 210 ... 490 350 ... 840 240 ... 560 400 ... 960 270 ... 630 450 ... 1080 300 ... 700 500 ... 1200 330 ... 770 550 ... 1320 375 ... 875 625 ... 1500 450 ... 900 900 ... 1800 600 ... 1200 1200 ... 2400 750 ... 900 1250 ... 2500 750 ... 1500 1500 ... 3000 Interrupting Ratings Frame 3VA51 3VA52 3VA53 3VA54 3VA55 3VA61 3VA62 3VA63 3VA64 3VA65 Breaker Type HEAP HFAP CFAP HJAP CHAP HLAP CLAP HMAP CMAP CDAR CFAR CJAR CLAR CMAR RMS Symmetrical Amperes (kA) Volts AC (50/60 Hz) 240 480 600Y/347V 600 150 65 25 -- 100 65 25 25 200 100 35 35 100 65 25 25 200 100 35 35 100 65 25 25 200 100 35 35 100 65 25 -- 100 100 50 -- 200 100 35 35 200 100 35 35 200 100 35 35 200 100 35 35 200 100 42 -- Selection Motor circuit protector TM120M AMb Frame Maximum (Breaker Ampere 3-Pole Type) Rating Catalog Number Instantaneous short circuit protection 3VA54 400 (HLAP 3VA5440-0MU31-0AA0 3VA5440-0MH31-0AA0 750 ... 1500 1200 ... 2400 500 3VA5450-0MU31-0AA0 1500 ... 3000 3VA5450-0MH31-0AA0 3000 ... 6000 600 3VA5460-0MU31-0AA0 1800 ... 3600 3VA5460-0MH31-0AA0 3000 ... 6000 3VA55 (HMAP) 600 3VA5560-0MH32-0AA0 4800 ... 9600 3VA52 150 (CFAP) 3VA5215-1MU31-0AA0 3VA5215-1MH31-0AA0 450 ... 900 900 ... 1800 200 3VA5220-1MU31-0AA0 600 ... 1200 3VA5220-1MH31-0AA0 1200 ... 2400 250 3VA5225-1MH31-0AA0 750 ... 900 3VA5225-1MU31-0AA0 1250 ... 2500 3VA53 250 (CJAP) 3VA5325-1MU31-0AA0 3VA5325-1MH31-0AA0 750 ... 1500 1500 ... 3000 3VA54 400 (CLAP) 3VA5440-1MU31-0AA0 3VA5440-1MH31-0AA0 750 ... 1500 2400 ... 4800 500 3VA5450-1MU31-0AA0 1500 ... 3000 3VA5450-1MH31-0AA0 3000 ... 6000 600 3VA5460-1MU31-0AA0 1500 ... 3000 3VA55 (CMAP) 600 3VA5460-1MH31-0AA0 3VA5560-1MH32-0AA0 3000 ... 6000 4800 ... 9600 Motor circuit protector ETU310Mb 3VA61 25 (CDAR) 30 40 50 70 80 90 100 3VA62 110 (CFAR-Y) 125 150 200 3VA63 200 (CJAR) 250 3VA64 400 (CLAR) 500 3VA65 (CMAR) 800 3VA6125-1MS31-0AA0 3VA6130-1MS31-0AA0 3VA6140-1MS31-0AA0 3VA6150-1MS31-0AA0 3VA6170-1MS31-0AA0 3VA6180-1MS31-0AA0 3VA6190-1MS31-0AA0 3VA6110-1MS31-0AA0 3VA6211-1MS31-0AA0 3VA6212-1MS31-0AA0 3VA6215-1MS31-0AA0 3VA6220-1MS31-0AA0 3VA6320-1MS31-0AA0 3VA6325-1MS31-0AA0 3VA6440-1MS31-0AA0 3VA6450-1MS31-0AA0 3VA6580-1MS32-0AA0 75 ... 375 90 ... 450 120 ... 600 150 ... 750 210 ... 1050 240 ... 1200 270 ... 1350 300 ... 1500 330 ... 1650 375 ... 1875 450 ... 2250 600 ... 2400 600 ... 3000 750 ... 3750 1200 ... 5200 1500 ... 6000 2400 ... 12000 Motor Circuit Protector a Rated at 600 Y/347 V AC. b SCCR is 100kA at 480 V. SCCR rating is the maximum permissible short circuit current of the MCP in combination with an appropriate overload protection device. c SCCR is 65kA at 480 V. SCCR rating is the maximum permissible short circuit current of the MCP in combination with an appropriate overload protection device. MOLDED CASE 7 CIRCUIT BREAKERS 7-82 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA Internal Accessories Internal Accessoriesc Auxiliary and Alarm Switches (Form C --> 1 NO and 1 NC) Switch Type Auxiliary Switch (AUX) HQ Leading Changeover Switch (LCS) HQ Trip/Bell Alarm Switch (TAS) HQ Electronic Alarm (EAS) HQ electronica Auxiliary Switch (AUX) HP Leading Changeover Switch (LCS) HP Trip/Bell Alarm Switch (TAS) HP Electronic Alarm (EAS) HPa Auxiliary Switch (AUX) HQ electronic Leading Changeover Switch (LCS) HQ electronic Trip/Bell Alarm Switch (TAS) HQ electronic Electronic Alarm (EAS) HQ electronica Width 1 slot AC 50/ 60 Hz 24 ... 300V 2 24 ... slots 600V 1 24 ... slot 300V DC 24 ... 250V 24 ... 250V 24 ... 250V Catalog Number 3VA9978-0AA12 3VA9978-0AA22 3VA9978-0AB12 3VA9978-0AB22 3VA9978-0AA11 3VA9978-0AA21 3VA9978-0AB11 -- 3VA9978-0AA13 3VA9978-0AA23 3VA9978-0AB13 3VA9978-0AB23 Shunt Trips Type VAC 50/60 Hz VDC Shunt Trip Left (STL) Shunt Trip Flexible (STF)b 380 ... 600 -- 24 48 ... 60 110 ... 127 208 ... 277 24 48 ... 60 110 ... 127 208 ... 277 380 ... 500 600 -- 12 24 ... 30 48 ... 60 110 ... 127 220 ... 250 -- -- -- -- -- -- Undervoltage Release Undervoltage Release (UVR) -- -- -- -- -- 24 120 ... 127 208 ... 230 440 ... 480 12 24 48 125 ... 127 250 -- -- -- -- Universal Release (Undervoltage and Shunt trip) -- 12 Universal Release (UNI) -- 24 -- 48 Catalog Number (3 slots) 3VA9978-0BL20 3VA9978-0BL10 3VA9978-0BL30 3VA9978-0BL31 3VA9978-0BL32 3VA9978-0BL33 3VA9978-0BA20 3VA9978-0BA21 3VA9978-0BA22 3VA9978-0BA23 3VA9978-0BA24 3VA9978-0BA25 3VA9978-0BB10 3VA9978-0BB11 3VA9978-0BB12 3VA9978-0BB14 3VA9978-0BB16 3VA9978-0BB20 3VA9978-0BB24 3VA9978-0BB25 3VA9978-0BB27 3VA9978-0BD11 3VA9978-0BD12 3VA9978-0BD13 Time-delay Device for Undervoltage Release Type Time-delay Device (mounted external to circuit breaker) VAC 50/60 Hz VDC 230 230 -- 24 Delay Time Fixed 100ms minimum Fixed 100ms minimum Catalog Number 3VA9978-0BF22 3VA9978-0BF23 Revised on 04/30/21 Selection Auxiliary switches and alarm switches HQ AUX LCS TAS EAS Auxiliary switches and alarm switches HP AUX LCS TAS Shunt trip left STL Undervoltage releases UVR Universal release UNI Time-delay device for undervoltage releases MOLDED CASE 7 CIRCUIT BREAKERS a Use only with 3VA6. b Shunt trip flexible can be used in the left pocket of the 3VA5 breakers. They can be used in the left or right pocket of the 3VA6 breakers. c Refer to pages 7-110 and 7-111 for internal accessory electrical requirements. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-83 3VA Molded Case Circuit Breakers Revised on 10/15/20 3VA Manual Operators Selection Front Mounted Rotary Operator Degree of protection NEMA 1 Type Standard without illumination kit Standard with illumination kit EMERGENCY-OFF without illumination kit EMERGENCY-OFF with illumination kit Standard with door interlock Standard with door interlock, with illumination kit EMERGENCY-OFF with door interlock EMERGENCY-OFF with door interlock, with illumination kit Standard with door interlock, with door open function Standard with door interlock, with door open function, with illumination kit EMERGENCY-OFF with door interlock, with door open function EMERGENCY-OFF with door interlock, with door open function, with illumination kit Color Gray Gray Yellow-Red Yellow-Red Gray Gray Yellow-Red Yellow-Red Gray Gray Yellow-Red Yellow-Red 3VA5 125A u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- 3VA5 250A -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- 3VA6 150A 250A -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- 3VA5 3VA6 400A 600A -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u -- -- u -- -- -- u 3VA5 3VA6 800A 1000A -- -- -- u -- -- -- -- -- -- u -- -- -- -- -- -- u -- -- -- -- -- -- u -- -- -- -- -- -- u -- -- -- -- -- -- u -- -- -- Catalog Number 3VA9137-0EK11 3VA9277-0EK11 3VA9447-0EK11 3VA9677-0EK11 3VA9137-0EK13 3VA9277-0EK13 3VA9447-0EK13 3VA9137-0EK15 3VA9277-0EK15 3VA9447-0EK15 3VA9677-0EK15 3VA9137-0EK17 3VA9277-0EK17 3VA9447-0EK17 3VA9137-0EK21 3VA9277-0EK21 3VA9447-0EK21 3VA9677-0EK21 3VA9137-0EK23 3VA9277-0EK23 3VA9447-0EK23 3VA9137-0EK25 3VA9277-0EK25 3VA9447-0EK25 3VA9677-0EK25 3VA9137-0EK27 3VA9277-0EK27 3VA9447-0EK27 3VA9137-0EK31 3VA9277-0EK31 3VA9447-0EK31 3VA9677-0EK31 3VA9137-0EK33 3VA9277-0EK33 3VA9447-0EK33 3VA9137-0EK35 3VA9277-0EK35 3VA9447-0EK35 3VA9677-0EK35 3VA9137-0EK37 3VA9277-0EK37 3VA9447-0EK37 MOLDED CASE 7 CIRCUIT BREAKERS 7-84 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers Revised on 10/31/21 3VA Manual Operators Selection Door Mounted Rotary Operatorab Type Standard Color Gray Standard with illumination kit Gray Degree of protection Type 1, 12, 3R and 4X EMERGENCY-OFF YellowRed EMERGENCY-OFF with illumination kit YellowRed Standard with door interlock, with open door function Gray Standard with door interlock, with open door function with illumination kit Gray EMERGENCY-OFF with door Yellow- interlock, with open door function Red EMERGENCY-OFF with door interlock, with open door function, with illumination kit Standard YellowRed Gray NFPA-79 Supplementary Handles EMERGENCY-OFF YellowRed 3VA5 125A u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- 3VA5 250A -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- 3VA6 150A 250A -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- 3VA5 3VA6 400A 600A -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- Side Mounted Rotary Operatora Standard Gray u -- -- -- -- u u -- Standard with illumination kit Gray u -- -- -- -- u u -- n Without mounting plate n Rotary operator with shaft 300 mm n Handle with masking plate 75 x 75 mm n Degree of protection Type 1, 12, 3R, 4X EMERGENCY-OFF EMERGENCY-OFF with illumination kit Yellow-Red u -- -- -- -- u u -- Yellow-Red u -- -- -- -- u u -- Standard with mounting plate Gray u -- -- -- -- u u -- Standard with mounting plate, with illumination kit Gray u -- -- -- -- u u -- EMERGENCY-OFF with Yellow-Red u -- -- -- n With mounting plate mounting plate -- u u -- n Rotary operator with short shaft n Handle with masking plate 75 x 75 mm EMERGENCY-OFF with mounting Yellow-Red u -- -- -- n Degree of protection Type 1, 12, 3R, 4X plate, with illumination kit -- u u -- Side Mounted Standard for use with the side wall mounted rotary operators n Without mounting plate Gray u -- -- -- -- u u -- Rotary Operator Door Interlock a Lockable with up to three padlock hasps. b All door mounted rotary operators include the tolerance compensation feature. 3VA5 3VA6 800A 1000A -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u -- -- -- u Catalog Number 3VA9137-0FK21 3VA9277-0FK21 3VA9447-0FK21 3VA9677-0FK21 3VA9137-0FK23 3VA9277-0FK23 3VA9447-0FK23 3VA9677-0FK23 3VA9137-0FK25 3VA9277-0FK25 3VA9447-0FK25 3VA9677-0FK25 3VA9137-0FK27 3VA9277-0FK27 3VA9447-0FK27 3VA9677-0FK27 3VA9137-0FK31 3VA9277-0FK31 3VA9447-0FK31 3VA9677-0FK31 3VA9137-0FK33 3VA9277-0FK33 3VA9447-0FK33 3VA9677-0FK33 3VA9137-0FK35 3VA9277-0FK35 3VA9447-0FK35 3VA9677-0FK35 3VA9137-0FK37 3VA9277-0FK37 3VA9447-0FK37 3VA9677-0FK37 3VA9137-0GC01 3VA9477-0GC01 3VA9477-0GC11 3VA9677-0GC01 3VA9137-0GC05 3VA9477-0GC05 3VA9477-0GC15 3VA9677-0GC05 -- 3VA9137-0PK11 -- 3VA9277-0PK11 -- 3VA9137-0PK13 -- 3VA9277-0PK13 -- 3VA9137-0PK15 -- 3VA9277-0PK15 -- 3VA9137-0PK17 -- 3VA9277-0PK17 -- 3VA9137-0PK51 -- 3VA9277-0PK51 -- 3VA9137-0PK53 -- 3VA9277-0PK53 -- 3VA9137-0PK55 -- 3VA9277-0PK55 -- 3VA9137-0PK57 -- 3VA9277-0PK57 -- 3VA9177-0VF40 -- 3VA9277-0VF40 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-85 MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers Revised on 10/15/20 3VA Manual Operators Breaker Operator Selection Type Without handle, without shaft adapter Color Gray Without handle, with shaft adapter Gray 3VA5 125A u -- -- -- 3VA5 250A -- u -- -- 3VA6 150A 250A -- u -- -- 3VA5 3VA6 400A 600A -- -- u -- 3VA5 3VA6 800A 1000A Catalog Number -- 3VA9137-0GK00 -- 3VA9277-0GK00 -- 3VA9447-0GK00 u 3VA9677-0GK00 3VA9277-0GK00 3VA9677-0GK00 Handles with Masking Plate (Purchase breaker operator, shaft and shaft adapter separately) n Degree of protection Type 1, 12, 3R and 4X Type Standard Color Gray Emergency YellowRed Tolerance Compensation Without With Without With Without With Without With Without With Without With Without With Without With Without With Without With Door Open Function Without Without Without Without With With With With With With Without Without Without Without With With With With With With 3VA5 125A u u -- -- u u -- -- -- -- u u -- -- u u -- -- -- -- 3VA5 250A u u -- -- u u -- -- -- -- u u -- -- u u -- -- -- -- 3VA6 150A 250A u u -- -- u u -- -- -- -- u u -- -- u u -- -- -- -- 3VA5 3VA6 400A 600A -- -- u u -- -- u u -- -- -- -- u u -- -- u u -- -- 3VA5 3VA6 800A 1000A -- -- -- -- -- -- -- -- u u -- -- -- -- -- -- -- -- u u Catalog Number 8UD1721-0AB11 8UD1721-0AB21 8UD1731-0AB11 8UD1731-0AB21 8UD1721-0AC11 8UD1721-0AC21 8UD1731-0AC11 8UD1731-0AC21 8UD1741-0AB11 8UD1741-0AB21 8UD1721-0AB15 8UD1721-0AB25 8UD1731-0AB15 8UD1731-0AB25 8UD1721-0AC15 8UD1721-0AC25 8UD1731-0AC15 8UD1731-0AC25 8UD1741-0AB15 8UD1741-0AB25 Metal Rotary Handles (Purchase breaker operator, shaft and shaft adapter separately) MOLDED CASE 7 CIRCUIT BREAKERS n Large, degree of protection Type 1, 3, 3R, 12 n Large, degree of protection Type 4, 4X n Compact, degree of protection Type 1,3,3R,12 n Compact, degree of protection Type 4, 4X n Long, degree of protection 1,3,3R,12 n Compact, degree of protection 1,3,3R,12 Metal Black -- Metal Stainless -- Compact Compact Black -- Stainless -- Emergency Red -- Emergency Red -- With With With With With With u u u u u RHOH u u u u u RHOH4 u u u u -- RHOHC u u u u -- RHOH4C u u u u u RHVPEMH u u u u -- RHVMEMH For additional information for selecting handle and breaker operator combinations, please refer to the brochure: https://digitalcontentcenter.compas.siemens-info.com/SIE_FL_3VA_Handles.pdf 7-86 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers Revised on 05/31/21 3VA Manual Operators Selection Pistol Grip Handles (Purchase breaker operator, shaft and shaft adapter separately) Degree of Protection Handle Type Color Tolerance Door Compen- Open 3VA5 sation Function 125A 3VA5 250A 3VA6 150A 250A 3VA5 3VA6 400A 600A 3VA5 3VA6 800A 1000A Catalog Number Type 1,3R,12 Plastic Gray -- With u u u u -- 3VA9477-0FH11 Type 4X Plastic (metal padlock hasp) Gray -- With u u u u -- 3VA9477-0FH41 Type 1,3R,12 Emergency Red -- With u u u u -- 3VA9477-0FH15 Emergency Type 4X (metal padlock Red -- hasp) With u u u u -- 3VA9477-0FH45 Door Mounted Rotary Operator Accessories Type 8 mm Shaft 300 mm/12 in long for 8UD plastic handles (Fixing bracket optional) 8 mm Shaft 600 mm/24 in long for 8UD plastic handles (Fixing bracket required) 12 mm Shaft 300 mm/12 in long for 8UD plastic handles 12 mm Shaft 600 mm/24 in long for 8UD plastic handles 8 mm Shaft 300 mm/12 in long for metal handles (Fixing bracket optional) 8 mm Shaft 600 mm/24 in long for metal handles (Fixing bracket required) 12 mm Shaft 300/12 in mm long for metal handles (Fixing bracket optional) 12 mm Shaft 600 mm/24 in long for metal handles (Fixing bracket required) 8 mm Shaft 300/12 in mm long for pistol grip handles (Fixing bracket optional) 8 mm Shaft 600 mm long/24 in for pistol grip handles (Fixing bracket required) 3VA5 125A u u -- -- u u -- -- u u 3VA5 250A u u -- -- u u -- -- u u 3VA6 150A 250A u u -- -- u u -- -- u u 3VA5 3VA6 400A 600A u u -- -- u u -- -- u u 3VA5 3VA6 800A 1000A -- Catalog Number 8UD1900-2WA00 -- 8UD1900-2WB00 u 8UD1900-4WA00 u 8UD1900-4WB00 -- 3VA9477-0GF20 -- 3VA9477-0GF21 u 3VA9877-0GF22 u 3VA9877-0GF23 -- 3VA9477-0GF10 -- 3VA9477-0GF11 Adapter for 8 mm Shaft for door mounted operator u u u u -- 8UD1900-2DA00 Adapter for 12 mm Shaft for door mounted operator -- -- -- -- u 8UD1900-4DA00 Fixing bracket for Shaft Fixing bracket for 12 mm x 12 mm shaft Variable depth adapter 8 x 8 mm u -- -- -- -- 3VA9137-0GA80 -- u u u -- 3VA9477-0GA80 -- -- -- -- u 3VA9677-0GA80 u u u u -- 3VA9487-0GB10 Door Coupling 8 mm x 8 mm (for 8UD plastic handles) Door coupling 12 mm x 12 mm (for 8UD plastic handles) Mounting tolerance compensation 8 x 8 mm (for 8UD plastic handles) Mounting tolerance compensation 12 mm x 12 mm (for 8UD plastic handles) u u u -- -- 8UD1900-2HA00 -- -- -- u u 8UD1900-4HA00 u u u u -- 8UD1900-2GA00 -- -- -- -- u 8UD1900-4GA00 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-87 3VA Molded Case Circuit Breakers 3VA Manual Operators General Accessories for Manual Operators Type Labeling plate for manual operators Details -- Revised on 04/30/21 Selection Part Number 3VA9087-0SX10 Illumination kit for manual operators 24 V DC voltage Cylinder Lock (type Kaba) n For 8UD plastic door mounted rotary operators (in masking plate) n Standard masking plate Cylinder Lock (type Kaba)a n For 8UD plastic door mounted rotary operators (in masking plate) n Standard masking plate Cylinder Lock (type Kaba) n For 8UD plastic door mounted rotary operators (in masking plate) n EMERGENCY-OFF masking plate Cylinder Lock (type Kaba)a n For 8UD plastic door mounted rotary operators (in masking plate) n EMERGENCY-OFF masking plate Cylinder Lock (type Ronis) n includes 2 keys n for locking or interlocking n installation in all rotary operators w/ shaft stub For Molded Case Circuit Breakers 3VA5, 125...250 A 3VA6, 150...600 A Front mounted rotary operators 3VA5, 3VA6, 125...600 A 3VA5, 3VA6, 800..1000A Door mounted rotary operators Key 1 Key 2 Key 3 Key 4 Key 1 Key 2 Key 3 Key 4 Key 1 Key 2 Key 3 Key 4 Key 1 Key 2 Key 3 Key 4 Key 1 Key 3 Key 4 Cylinder lock adapter for 8UD rotary operator n to mount in rotary operator 8UD1900-0KA10 8UD1900-0KA20 8UD1900-0KA20 8UD1900-0KA30 8UD1900-0MB01 8UD1900-0NB01 8UD1900-0PB01 8UD1900-0QB01 8UD1900-0MC01 8UD1900-0NC01 8UD1900-0PC01 8UD1900-0QC01 8UD1900-0MB05 8UD1900-0NB05 8UD1900-0PB05 8UD1900-0QB05 8UD1900-0MC05 8UD1900-0NC05 8UD1900-0PC05 8UD1900-0QC05 3VA9980-0VL10 3VA9980-0VL30 3VA9980-0VL40 3VA9980-0LF20 Cylinder lock adaptor for front mounted rotary operator 3VA9677-0EK.. and door mounted rotary operator 3VA9677-0FK.. 3VA55/3VA65/3VA66 3VA9670-0LF20 MOLDED CASE 7 CIRCUIT BREAKERS a With door open function 7-88 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA Manual and Motor Operators Selection Max Flex Operator Complete kit and spare mechanism Type Complete Kit n Operating mechanism n Plastic handle, NEMA 1/12, black=OFF, green=ON n Bowden Cable 36 inches (0.9m) long Complete Kit n Operating mechanism n Steel handle, epoxy coated NEMA 1/3R/12, black=OFF, red=ON, n Bowden Cable 36 inches (0.9m) long Operating Mechanism (spare) Handle - Plastic, NEMA 1/12, black = OFF, green = ON Handle - Steel, Epoxy coated, NEMA 1/3R/12, black = OFF, red = ON Handle - Steel, Epoxy coated, NEMA 1/3R/12, black = OFF, black = ON Handle - Steel, chrome-plated, NEMA 4/4X, black = OFF, red = ON Handle - Steel, chrome-plated, NEMA 4/4X, black = OFF, black = ON Handle - Stainless steel, NEMA 4, 4X, red = ON, black =OFF Bowden Cable, 36 inches (0.9m) Bowden Cable, 48 inches (1.2m) Bowden Cable, 60 inches (1.5m) Bowden Cable, 72 inches (1.8m) Bowden Cable, 84 inches (2.1m) Bowden Cable, 96 inches (2.4m) Bowden Cable, 120 inches (3.0m) Bowden Cable, 144 inches (3.6m) Bowden Cable, 36 inches (0.9m) Bowden Cable, 48 inches (1.2m) Bowden Cable, 60 inches (1.5m) Bowden Cable, 72 inches (1.8m) Bowden Cable, 84 inches (2.1m) Bowden Cable, 96 inches (2.4m) Bowden Cable, 120 inches (3.0m) Bowden Cable, 144 inches (3.6m) Bowden Cable, 48 inches (1.2m) Bowden Cable, 60 inches (1.5m) Bowden Cable, 72 inches (1.8m) Bowden Cable, 96 inches (2.4m) Bowden Cable, 120 inches (3.0m) Bowden Cable, 144 inches (3.6m) MaxFlex Auxiliary switch (leading from On to Off) n 1 CO MaxFlex Auxiliary switch (leading from On to Off) n 2 CO 3VA5 125A u -- -- u -- -- -- u -- -- -- u u -- u -- u u -- u u u u u u u u -- -- -- -- -- -- -- -- -- -- -- -- -- -- u u 3VA5 250A -- u -- -- u -- -- -- u -- -- u u -- u -- u u -- u u u u u u u u -- -- -- -- -- -- -- -- -- -- -- -- -- -- u u 3VA6 150A 250A -- u -- 3VA5 3VA6 400A 600A -- -- u -- -- u -- -- u -- -- -- -- u -- -- u -- -- u u u u -- -- u u -- -- u u u u -- -- u -- u -- u -- u -- u -- u -- u -- u -- -- u -- u -- u -- u -- u -- u -- u -- u -- -- -- -- -- -- -- -- -- -- -- -- u u u u 3VA5 3VA6 800A 1000A -- -- -- Catalog Number 3VA9137-0CK12 3VA9277-0CK12 3VA9477-0CK12 -- 3VA9137-0CK72 -- 3VA9277-0CK72 -- 3VA9477-0CK72 u 3VA9677-0CK72 -- 3VA9137-0CB10 -- 3VA9277-0CB10 -- 3VA9477-0CB10 u 3VA9677-0CB10 -- 3VA9977-0CH12 -- 3VA9977-0CH72 u 3VA9877-0CH72 -- 3VA9977-0CH74 u 3VA9877-0CH74 -- 3VA9977-0CH82 -- 3VA9977-0CH84 u 3VA9877-0CH82 -- 3VA9278-0CC10 -- 3VA9278-0CC20 -- 3VA9278-0CC30 -- 3VA9278-0CC40 -- 3VA9278-0CC50 -- 3VA9278-0CC60 -- 3VA9278-0CC70 -- 3VA9278-0CC80 -- 3VA9578-0CC10 -- 3VA9578-0CC20 -- 3VA9578-0CC30 -- 3VA9578-0CC40 -- 3VA9578-0CC50 -- 3VA9578-0CC60 -- 3VA9578-0CC70 -- 3VA9578-0CC80 u 3VA9877-0CC20 u 3VA9877-0CC30 u 3VA9877-0CC40 u 3VA9877-0CC60 u 3VA9877-0CC70 u 3VA9877-0CC80 u 3VA9478-0CX10 u 3VA9478-0CX20 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-89 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA Manual and Motor Operators Variable depth flange mounted operator kit Type Complete kit comprising: n Switching mechanism adjustable depth 200mm to 400mm n Epoxy coated steel handle, NEMA 1/3R/12, black = OFF, red = ON Complete kit comprising: n Switching mechanism adjustable depth 200mm to 400mm n Stainless steel handle, chrome-plated NEMA 4/4X, black=OFF, red=ON Complete kit comprising: n Swithching mechanism adjustable depth 200mm to 400mm n Handle stainless steel, chrome-plated NEMA 4/4X, black=OFF, black=ON Selection 3VA5 125A u -- -- 3VA5 250A -- u -- 3VA6 150A 250A -- u -- 3VA5 3VA6 400A 600A -- -- u Catalog Number 3VA9138-0DK72 3VA9278-0DK72 3VA9478-0DK72 u -- -- -- 3VA9138-0DK82 -- u u -- 3VA9278-0DK82 -- -- -- u 3VA9478-0DK82 u -- -- -- 3VA9138-0DK84 -- u u -- 3VA9278-0DK84 -- -- -- u 3VA9478-0DK84 Motor Operatorsa Type 3VA5 125 A Motor Operator without Stored Energy Feature 24 ... 60 V DC u -- -- 110 ... 230 V AC u 110 ... 250 V DC -- -- Motor Operator with Stored Energy Feature 24 V DC -- 42 ... 60 V AC/DC -- 110 ... 230 V AC / 110 ... 250 V DC -- Motor Operator with Stored Energy Feature with Communication 24 V DC -- 110 ... 230 V AC / 110 ... 250 V DC -- a Lockable with up to three padlock hasps. 3VA6 3VA5 150 A 250 A 250 A 3VA5 3VA6 400A 600A -- -- -- u u -- -- -- u -- -- -- u u -- -- -- u u u -- u u -- u u -- u u -- u u -- Part Number 3VA9137-0HA10 3VA9277-0HA10 3VA9447-0HA10 3VA9137-0HA20 3VA9277-0HA20 3VA9447-0HA20 3VA9277-0HC10 3VA9277-0HC20 3VA9277-0HC30 3VA9277-0HC15 3VA9277-0HC35 MOLDED CASE 7 CIRCUIT BREAKERS 7-90 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers Revised on 06/30/21 3VA Connection Technology Selection Box Terminals Type Steel wrap-around lug (Cu cable only) kit of 3 single lugs Steel wrap-around lug (Cu cable only) kit of 4 single lugs Steel wrap-around lug with control wire tap (Cu cable only) kit of 3 single lugs Steel wrap-around lug with control wire tap (Cu cable only) kit of 4 single lugs Aluminum Wire Connectors Aluminum body lug small (Cu/Al cable) kit of 3 single lugs Aluminum body lug small (Cu/Al cable) kit of 4 single lugs Aluminum body lug small with control wire tap (Cu/Al cable) Aluminum body lug small with control wire tap (Cu/Al cable) Aluminum body lug (Cu/Al cable) kit of 3 single lugs Aluminum body lug (Cu/Al cable) kit of 4 single lugs Aluminum body lug with control wire tap (Cu/Al cable) kit of 3 single lugs Aluminum body lug with control wire tap (Cu/Al cable) kit of 4 single lugs Aluminum body lug two cables (Cu/Al cable) kit of 3 single lugs Minimum cable crosssection (standard) Class B AWG 14 AWG 10 AWG 4 AWG 10 AWG 4 1/0 AWG 14 AWG 10 AWG 4 AWG 10 AWG 4 1/0 AWG 10 AWG 4 AWG 10 AWG 4 1/0 AWG 10 AWG 4 AWG 10 AWG 4 1/0 AWG 14 AWG 14 AWG 14 AWG 14 AWG 8 AWG 14 AWG 6 AWG 14 AWG 6 2/0 AWG 8 AWG 14 AWG 6 AWG 14 AWG 6 2/0 AWG 8 AWG 14 AWG 6 AWG 14 AWG 6 2/0 AWG 8 AWG 14 AWG 6 AWG 14 AWG 6 2/0 4/0 Maximum cable crosssection (standard) Class B 3/0 3/0 350 kcmil 3/0 350 kcmil 500 kcmil 3/0 3/0 350 kcmil 3/0 350 kcmil 500 kcmil 3/0 350 kcmil 3/0 350 kcmil 500 kcmil 3/0 350 kcmil 3/0 350 kcmil 500 kcmil AWG 8 AWG 8 AWG 8 AWG 8 3/0 1/0 350 kcmil 1/0 350 kcmil 600 kcmil 3/0 1/0 350 kcmil 1/0 350 kcmil 600 kcmil 3/0 1/0 350 kcmil 1/0 350 kcmill 600 kcmil 3/0 1/0 350 kcmil 1/0 350 kcmil 600 kcmil 600 kcmil For molded case circuit breakers/rated current 3VA5 125A u -- -- -- -- -- u -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 3VA5 250A -- u u -- -- -- -- u u -- -- -- u u -- -- -- u u -- -- -- 3VA6 150A 250A -- -- -- u u -- -- -- -- u u -- -- -- u u -- -- -- u u -- 3VA5 3VA6 400A 600A -- -- -- -- -- u -- -- -- -- -- u -- -- -- -- u -- -- -- -- u 3VA5 3VA6 800A 1000A -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Part Number 3VA9133-0JA11 3VA9233-0JA11 3VA9233-0JA12 3VA9143-0JA12 3VA9243-0JA12 3VA9473-0JA13 3VA9134-0JA11 3VA9234-0JA11 3VA9234-0JA12 3VA9144-0JA12 3VA9244-0JA12 3VA9474-0JA13 3VA9233-0JH11 3VA9233-0JH12 3VA9143-0JH12 3VA9243-0JH12 3VA9473-0JH13 3VA9234-0JH11 3VA9234-0JH12 3VA9144-0JH12 3VA9244-0JH12 3VA9474-0JH13 u -- -- -- -- 3VA9133-0JB10ce u -- -- -- -- 3VA9134-0JB10ce u -- -- -- -- 3VA9133-0JG10c u -- -- -- -- 3VA9134-0JG10c u -- -- -- -- 3VA9133-0JB11de -- u -- -- -- 3VA9233-0JB11 -- u -- -- -- 3VA9233-0JB12be -- -- u -- -- 3VA9143-0JB11b -- -- u -- -- 3VA9243-0JB12e -- -- -- u -- 3VA9373-0JB13ae u -- -- -- -- 3VA9134-0JB11de -- u -- -- -- 3VA9234-0JB11 -- u -- -- -- 3VA9234-0JB12e -- -- u -- -- 3VA9144-0JB11b -- -- u -- -- 3VA9244-0JB12be -- -- -- u -- 3VA9374-0JB13ae u -- -- -- -- 3VA9133-0JG11d -- u -- -- -- 3VA9233-0JG11 -- u -- -- -- 3VA9233-0JG12 -- -- u -- -- 3VA9143-0JG11b -- -- u -- -- 3VA9243-0JG12b -- -- -- u -- 3VA9373-0JG13a u -- -- -- -- 3VA9134-0JG11d -- u -- -- -- 3VA9234-0JG11 -- u -- -- -- 3VA9234-0JG12 -- -- u -- -- 3VA9144-0JG11b -- -- u -- -- 3VA9244-0JG12b -- -- -- u -- 3VA9374-0JG13a -- -- -- -- u 3VA9573-0JB23f a This conductor is ampere-rated at 380A with copper wire and 310A with aluminum wire. bMeets requirements of 100% rated breakers up to 150A. c Use these lugs on 15A to 40A breakers. d Use these lugs on 45A to 125A breakers. e Standard lug installed at the factory when the breaker is ordered with a "6" in the 12th position of the catalog number. f Standard lug installed at the factory on 600/700A 3VA55 and 600A 3VA65 breakers when the breaker is ordered with "6" in the 12th position of the catalog number. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-91 MOLDED CASE 7 CIRCUIT BREAKERS 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA Connection Technology Selection Aluminum Wire Connectors (cont.) 3 lug kit pictured 4 lug kit pictured Type Aluminum body lug two cables (Cu/Al cable) kit of 4 single lugs Aluminum body lug two cables with control wire tap (Cu/Al cable) kit of 3 single lugs Aluminum body lug two cables with control wire tap (Cu/Al cable) kit of 4 single lugs Aluminum body lug three cables (Cu/Al cable) kit of 3 single lugs Aluminum body lug three cables (Cu/Al cable) kit of 4 single lugs Aluminum body lug three cables with control wire tap (Cu/Al cable) kit of 3 single lugs Aluminum body lug three cables with control wire tap (Cu/Al cable) kit of 4 single lugs Minimum cable crosssection (standard) Class B 4/0 4/0 4/0 4/0 4/0 4/0 4/0 Maximum cable crosssection (standard) Class B 600 kcmil 600 kcmil 600 kcmil 400 kcmil 400 kcmil 400 kcmil 400 kcmil For molded case circuit breakers/rated current 3VA5 125A -- 3VA5 250A -- 3VA6 150A 250A -- 3VA5 3VA6 400A 600A -- 3VA5 3VA6 800A 1000A u Part Number 3VA9574-0JB23b -- -- -- -- u 3VA9673-0JG23 -- -- -- -- u 3VA9674-0JG23 -- -- -- -- -- -- -- -- -- -- -- -- u 3VA9673-0JB32 u 3VA9674-0JB32 u 3VA9673-0JG32 -- -- -- -- u 3VA9674-0JG32 MOLDED CASE 7 CIRCUIT BREAKERS Aluminum Wire Connectors and Terminal Covers Type Aluminum body lug large (Cu/Al cable) 2 lug 3 lug 4 lug Aluminum body lug large with control wire tap (Cu/Al cable) Description Kit of 2 single lugs and 1 extended terminal cover Kit of 3 single lugs and 1 extended terminal cover Kit of 4 single lugs and 1 extended terminal cover Min. cable crosssection (std.) Class B AWG 4 AWG 4 AWG 2 AWG 2 AWG 4 AWG 2 AWG 2 Max. cable crosssection (std.) Class B 300 kcmil For molded case circuit breakers/ rated current 3VA5 3VA5 3VA6 3VA6 3VA6 3VA5 3VA5 150A 400A 800A 125A 250A 250A 600A 1000A Part Number u -- -- -- -- 3VA9132-0JJ12 Terminal Cover with Probe Holes Part Number 300 kcmil u -- -- -- -- 3VA9133-0JJ12 350 kcmil -- u -- -- -- 3VA9233-0JJ13 350 kcmil -- -- u -- -- 3VA9243-0JJ13a 300 kcmil u -- -- -- -- 3VA9134-0JJ12 350 kcmil -- u -- -- -- 3VA9234-0JJ13 350 kcmil -- -- u -- -- 3VA9244-0JJ13a Kit of 2 single lugs and AWG 4 300 kcmil u -- -- -- -- 3VA9132-0JC12 1 extended terminal cover Kit of 3 single lugs and AWG 4 300 kcmil u -- -- -- -- 3VA9133-0JC12 3VA9133-0JC18 1 extended terminal cover AWG 2 350 kcmil -- u -- -- -- 3VA9233-0JC13 3VA9233-0JC18 AWG 2 350 kcmil -- -- u -- -- 3VA9243-0JC13a 3VA9243-0JC18 2 lug 3 lug 4 lug Aluminum body lug, 2 Cables (Cu/Al cable) Kit of 4 single lugs and AWG 4 300 kcmil u -- -- -- -- 3VA9134-0JC12 1 extended terminal cover AWG 2 350 kcmil -- u -- -- -- 3VA9234-0JC13 AWG 2 350 kcmil -- -- u -- -- 3VA9244-0JC13a Kit of 3 single lugs and AWG 4 300 kcmil -- u -- -- -- 3VA9233-0JJ22 1 extended terminal cover AWG 4 300 kcmil -- -- u -- -- 3VA9243-0JJ22a 2/0 600 kcmil -- -- -- u -- 3VA9473-0JJ23 3 lug 4 lug Kit of 4 single lugs and AWG 4 300 kcmil -- u ---- -- 3VA9234-0JJ22 1 extended terminal cover AWG 4 300 kcmil -- -- u -- -- 3VA9244-0JJ22a 2/0 600 kcmil -- -- -- u -- 3VA9474-0JJ23 a Meets requirements of 100% rated breakers up to 250A. b Standard lug installed at the factory on 600/700A 3VA55 and 600A 3VA65 breakers when the breaker is ordered with "6" in the 12th position of the catalog number. 7-92 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA Connection Technology Selection Aluminum Wire Connectors and Terminal Covers (cont.) Type Aluminum body lug, 2 Cables with control wire tap (Cu/Al cable) Description Kit of 3 single lugs and 1 extended terminal cover Min. cable crosssection (std.) Class B AWG 4 AWG 4 2/0 Max. cable crosssection (std.) Class B 300 kcmil 300 kcmil 600 kcmil For molded case circuit breakers/ rated current 3VA5 3VA5 3VA6 3VA6 3VA6 3VA5 3VA5 150A 400A 800A 125A 250A 250A 600A 1000A Part Number Terminal Cover with Probe Holes Part Number -- u -- -- 3VA9233-0JC22 3VA9233-0JC28 -- -- u -- 3VA9243-0JC22a 3VA9243-0JC28 ------ u 3VA9473-0JC23 3VA9473-0JC28 3 lug 4 lug Aluminum body lug two cables (Cu/Al cable) 3 lug kit pictured Kit of 4 single lugs and AWG 4 300 kcmil -- u -- -- 1 extended terminal cover AWG 4 300 kcmil -- -- u -- 2/0 600 kcmil -- -- -- u 3VA9234-0JC22 3VA9244-0JC22a 3VA9474-0JC23 Kit of 3 single lugs and 400 kcmil 750 kcmil -- -- -- -- 1 extended terminal cover Kit of 4 single lugs and 400 kcmil 750 kcmil -- -- -- -- 1 extended terminal cover u 3VA9673-0JJ24 u 3VA9674-0JJ24 MOLDED CASE 7 CIRCUIT BREAKERS Aluminum body lug two cables with control wire tap (Cu/Al cable) 3 kit lug pictured Kit of 3 single lugs and 400 kcmil 750 kcmil -- -- -- 1 extended terminal cover Kit of 4 single lugs and 400 kcmil 750 kcmil -- -- -- 1 extended terminal cover Aluminum body lug three cables (Cu/Al cable) Kit of 3 single lugs and 500 kcmil 750 kcmil -- -- -- 1 extended terminal cover Kit of 4 single lugs and 500 kcmil 750 kcmil -- -- -- 1 extended terminal cover Aluminum body lug three cables Kit of 3 single lugs and 500 kcmil 750 kcmil -- -- -- with control wire tap (Cu/Al cable) 1 extended terminal cover Kit of 4 single lugs and 500 kcmil 750 kcmil -- -- -- 1 extended terminal cover Aluminum body lug four cables (Cu/Al cable) 4 lug kit pictured Kit of 3 single lugs and 4/0 1 extended terminal cover Kit of 4 single lugs and 4/0 1 extended terminal cover 500 kcmil -- -- -- 500 kcmil -- -- -- Aluminum body lug four cables with control wire tap (Cu/Al cable) 4 lug kit pictured Kit of 3 single lugs and 4/0 1 extended terminal cover Kit of 4 single lugs and 4/0 1 extended terminal cover 500 kcmil -- -- -- 500 kcmil -- -- -- Aluminum body lug four cables (Cu/Al cable) Kit of 3 single lugs and 4/0 1 extended terminal cover 600 kcmil -- -- -- Kit of 4 single lugs and 4/0 1 extended terminal cover 600 kcmil -- -- -- Aluminum body lug four cables Kit of 3 single lugs and 4/0 with control wire tap (Cu/Al cable) 1 extended terminal cover 600 kcmil -- -- -- Distribution lug, 6 Cables (Cu/Al cable) Kit of 4 single lugs and 4/0 600 kcmil -- -- -- 1 extended terminal cover Kit of 2 single lugs and AWG 14 AWG 2 u -- -- 1 extended terminal cover Kit of 3 single lugs and AWG 14 AWG 2 1 extended terminal cover AWG 2 u ---- -- u -- AWG 2 -- -- u AWG 2 ------ Kit of 4 single lugs and AWG 14 AWG 2 1 extended terminal cover AWG 2 u ---- -- u -- 2 lug 3 lug 4 lug AWG 2 -- -- u AWG 2 ------ a Meets requirements of 100% rated breakers up to 250A. b Meets requirements of 100% rated breakers up to 100A. c Meets requirements of 100% rated breakers up to 100A. d Standard lug shipped from the factory with the breaker for field installation on 800A 3VA55 and 800/1000A -- u 3VA9673-0JC24 -- u 3VA9674-0JC24 -- u 3VA9673-0JJ34 -- u 3VA9674-0JJ34 -- u 3VA9673-0JC34 -- u 3VA9674-0JC34 -- u 3VA9673-0JJ43d -- u 3VA9674-0JJ43d -- u 3VA9673-0JC43 -- u 3VA9674-0JC43 -- u 3VA9673-0JJ44 -- u 3VA9674-0JJ44 -- u 3VA9673-0JC44 -- u 3VA9674-0JC44 -- 3VA9132-0JF60 -- 3VA9133-0JF60 3VA9133-0JF68 -- 3VA9233-0JF60 3VA9233-0JF68 -- 3VA9243-0JF60b 3VA9243-0JF68 u 3VA9373-0JF60c 3VA9373-0JF68 -- 3VA9134-0JF60 -- 3VA9234-0JF60 -- 3VA9244-0JF60b u 3VA9374-0JF60c 3VA65 and 3VA66 when the breaker is ordered with a "6" in the 12th position of the catalog number. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-93 3VA Molded Case Circuit Breakers Revised on 06/30/21 3VA Connection Technology Selection Copper Wire Connectors Type Copper body lug, small (Cu cable only) Kit of 3 single lugs Minimum cable crosssection (standard) Class B AWG 14 Maximum cable crosssection (standard) Class B AWG 8 For molded case circuit breakers/ rated current 3VA5 125A 3VA6 3VA5 150A 250A 250A 3VA5 3VA6 400A 600A 3VA5 3VA6 800A 1000A u -- -- -- -- Part Number 3VA9133-0JD10a Copper body lug (Cu cable only) Kit of 3 single lugs Copper body lug, small (Cu cable only) Kit of 4 single lugs AWG 8 AWG 14 AWG 6 AWG 14 AWG 6 2/0 AWG 14 2/0 1/0 350 kcmil 1/0 350 kcmil 600 kcmil AWG 8 u -- -- -- -- 3VA9133-0JD11b -- u -- -- -- 3VA9233-0JD11 -- u -- -- -- 3VA9233-0JD12 -- -- u -- -- 3VA9143-0JD11 -- -- u -- -- 3VA9243-0JD12c -- -- -- u -- 3VA9373-0JD13d u -- -- -- 3VA9134-0JD10a Copper body lug (Cu cable only) kit of 4 single lugs Copper body lug, three cables (Cu cable) Kit of 3 single lugs Copper body lug, three cables (Cu cable) Kit of 4 single lugs Copper body lug, small with control wire tap (Cu cable only) Kit of 3 single lugs Copper body lug with control wire tap (Cu cable only) Kit of 3 single lugs Copper body lug, small with control wire tap (Cu cable only) Kit of 4 single lugs AWG 8 AWG 14 AWG 6 AWG 14 AWG 6 2/0 4/0 4/0 AWG 14 AWG 8 AWG 14 AWG 6 AWG 14 AWG 6 2/0 AWG 14 Copper body lug with control wire tap (Cu cable only) Kit of 4 single lugs Copper body lug, three cables with control wire tap (Cu cable) Kit of 3 single lugs Copper body lug, three cables with control wire tap (Cu cable) Kit of 4 single lugs AWG 8 AWG 14 AWG 6 AWG 14 AWG 6 2/0 400 kcmil 400 kcmil 2/0 1/0 350 kcmil 1/0 350 kcmil 600 kcmil 400 kcmil 400 kcmil AWG 8 2/0 1/0 350 kcmil 1/0 350 kcmil 600 kcmil AWG 8 2/0 1/0 350 kcmil 1/0 350 kcmil 600 kcmil 600 kcmil 600 kcmil u -- -- -- -- 3VA9134-0JD11b -- u -- -- -- 3VA9234-0JD11 -- u -- -- -- 3VA9234-0JD12 -- -- u -- -- 3VA9144-0JD11 -- -- u -- -- 3VA9244-0JD12c -- -- -- u -- 3VA9374-0JD13d -- -- -- -- u 3VA9673-0JD32 -- -- -- -- u 3VA9674-0JD32 u -- -- -- 3VA9133-0JK10a u -- -- -- -- 3VA9133-0JK11b -- u -- -- -- 3VA9233-0JK11 -- u -- -- -- 3VA9233-0JK12 -- -- u -- -- 3VA9143-0JK11 -- -- u -- -- 3VA9243-0JK12 -- -- -- u -- 3VA9373-0JK13 u -- -- -- 3VA9134-0JK10a u -- -- -- -- 3VA9134-0JK11b -- u -- -- -- 3VA9234-0JK11 -- u -- -- -- 3VA9234-0JK12 -- -- u -- -- 3VA9144-0JK11 -- -- u -- -- 3VA9244-0JK12 -- -- -- u -- 3VA9374-0JK13 -- -- -- -- u 3VA9673-0JK32 -- -- -- -- u 3VA9674-0JK32 MOLDED CASE 7 CIRCUIT BREAKERS a Use these lugs on 15A to 40A breakers. b Use these lugs on 45A to 125A breakers. c Standard lug installed at the factory on 100% rated 250A 3VA62 breakers when ordered with a "6" in the 12th position of the catalog number. 7-94 Siemens Industry, Inc. SPEEDFAXTM Product Catalog d Standard lug installed at the factory on 100% rated 400A 3VA64 breakers when ordered with a "6" in the 12th position of the catalog number. 3VA Molded Case Circuit Breakers Revised on 08/31/20 3VA Connection Technology Copper Wire Connectors (cont.) Type Copper body lug, 2 Cables (Cu cable only) Kit of 3 single lugs and 1 extended terminal cover Selection Minimum cable crosssection (standard) Class B 2/0 Maximum cable crosssection (standard) Class B 600 kcmil For molded case circuit breakers/ rated current 3VA5 125A 3VA6 3VA5 150A 250A 250A 3VA5 3VA6 400A 600A 3VA5 3VA6 800A 1000A -- -- -- u -- Part Number 3VA9473-0JE23 Copper body lug 2 Cables (Cu 2/0 cable only) Kit of 4 single lugs and 1 extended terminal cover 600 kcmil -- -- -- u -- 3VA9474-0JE23 Copper body lug, four cables 4/0 (Cu cable) Kit of 3 single lugs and 1 extended terminal cover Copper body lug, four cables 4/0 (Cu cable) Kit of 4 single lugs and 1 extended terminal cover Copper body lug, four cables 4/0 (Cu cable) Kit of 3 single lugs and 1 extended terminal cover Copper body lug, four cables 4/0 (Cu cable) Kit of 4 single lugs and 1 extended terminal cover 500 kcmil -- -- -- -- u 3VA9673-0JE43 500 kcmil -- -- -- -- u 3VA9674-0JE43 500 kcmil -- -- -- -- u 3VA9673-0JL43 500 kcmil -- -- -- -- u 3VA9674-0JL43 Nut Keeper Kits 4 lug kit pictured Type Nut keeper kit kit of 3 single lugs Nut keeper kit kit of 4 single lugs Nut keeper kit kit of 3 single lug and terminal covers Nut keeper kit kit of 4 single lug and terminal covers Maximum terminal width 17 mm / 0.7 inch 25 mm / 1 inch 25 mm / 1 inch 35 mm / 1.4 inch 17 mm / 0.7 inch 25 mm / 1 inch 25 mm / 1 inch 35 mm / 1.4 inch 50 mm / 2.0 inch 50 mm / 2.0 inch Maximum terminal thickness 6.5 mm /0.25 inch 8 mm / 0.3 inch 8 mm / 0.3 inch 10 mm / 0.4 inch 6.5 mm /0.25 inch 8 mm / 0.3 inch 8 mm / 0.3 inch 10 mm / 0.4 inch 30 mm / 1.18 inch 30 mm / 1.18 inch For molded case circuit breakers/ rated current 3VA5 125A 3VA6 3VA5 150A 250A 250A 3VA5 3VA6 400A 600A 3VA5 3VA6 800A 1000A u -- -- -- -- -- u -- -- -- -- -- u -- -- -- -- -- u -- u -- -- -- -- -- u -- -- -- -- -- u -- -- -- -- -- u -- -- -- -- -- u -- -- -- -- u Part Number 3VA9133-0QA00 3VA9233-0QA00 3VA9243-0QA00 3VA9473-0QA00 3VA9134-0QA00 3VA9234-0QA00 3VA9244-0QA00 3VA9474-0QA00 3VA9673-0QA00 3VA9674-0QA00 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-95 3VA Molded Case Circuit Breakers Revised on 04/30/21 3VA Connection Technology Selection Bus Connector Extensions Type Front bus connectors extended 1 single connector Maximum terminal width 22 mm / 0.9 inch Maximum terminal thickness 8 mm / 0.3 inch For molded case circuit breakers/ rated current 3VA5 125A 3VA6 3VA5 150A 250A 250A 3VA5 3VA6 400A 600A 3VA5 3VA6 800A 1000A u -- -- -- -- Part Number 3VA9131-0QB00 Front bus connectors extended kit of 3 single connectors, 2 phase barriers, and 1 insulating plate 22 mm / 0.9 inch 8 mm / 0.3 inch Front bus connectors extended kit of 4 single connectors, 3 phase barriers, and 1 insulating plate 22 mm / 0.9 inch 8 mm / 0.3 inch u -- -- -- -- 3VA9133-0QB00 u -- -- -- -- 3VA9133-0QB00 Front bus connectors 32 mm / 10 mm / -- u u -- -- 3VA9273-0QB00 extended kit of 3 single connectors 1.3 inch 0.4 inch and 1 insulating plate 40 mm / 12.5 mm / -- -- -- u -- 3VA9473-0QB00 1.6 inch 0.5 inch 50.8 mm / 2.0 inch 30 mm / 1.18 inch -- -- -- -- u 3VA9673-0QB00 Front bus connectors 32 mm / 10 mm / -- u u -- -- 3VA9274-0QB00 extended kit of 4 single connectors 1.3 inch 0.4 inch and 1 insulating plate 40 mm / 12.5 mm / -- -- -- u -- 3VA9474-0QB00 1.6 inch 0.5 inch 50.8 mm / 2.0 inch 30 mm / 1.18 inch -- -- -- -- u 3VA9674-0QB00 Front bus connectors 60 mm / 12.5 mm / -- -- -- u -- 3VA9473-0QC00 offset kit of 3 single connectors 2.4 inch 0.5 inch 1 insulating plate Distance between pole centers: 400/600 A = 70 mm / 2.76 inches 80 mm / 3.15 inch 30 mm / 1.18 inch -- -- -- -- u 3VA9673-0QC00 Front bus connectors 60 mm / 12.5 mm / -- -- -- u -- 3VA9474-0QC00 offset kit of 4 single connectors 2.4 inch 0.5 inch 1 insulating plate Distance between pole centers: 400/600 A = 70 mm / 2.76 inches 80 mm / 3.15 inch 30 mm / 1.18 inch -- -- -- -- u 3VA9674-0QC00 MOLDED CASE 7 CIRCUIT BREAKERS 7-96 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA Connection Technology Rear connection studs flat Type Rear connection studs flat kit of 2 short flat studs and 1 long flat stud Rear connection studs flat kit of 2 short flat studs and 2 long flat studs Rear connection studs flat 1 short flat stud Rear connection studs flat 1 long flat stud Rear connection studs round Rear connection studs round kit of 1 long round stud and 2 short round studs Rear connection studs round kit of 2 long round studs and 2 short round studs Rear connection studs round 1 short round studs Rear connection studs round 1 long round stud Revised on 08/31/20 Selection For molded case circuit breakers/ rated current 3VA5 125A u -- -- -- -- u -- -- -- 3VA5 250A -- u -- -- -- -- u -- -- 3VA6 150A 250A -- -- u -- -- -- -- u -- 3VA5 3VA6 400A 600A -- -- -- u -- -- -- -- u 3VA5 3VA6 800A 1000A -- -- -- -- u -- -- -- -- -- -- -- -- u u -- -- -- -- -- u -- -- -- -- -- u -- -- -- -- -- u -- u -- -- -- -- -- u -- -- -- -- -- u -- -- -- -- -- u -- Part Number 3VA9133-0QE00 3VA9233-0QE00 3VA9243-0QE00 3VA9473-0QE00 3VA9673-0QE00 3VA9134-0QE00 3VA9234-0QE00 3VA9244-0QE00 3VA9474-0QE00 3VA9674-0QE00 3VA9131-0QE10 3VA9231-0QE10 3VA9241-0QE10 3VA9471-0QE10 3VA9131-0QE20 3VA9231-0QE20 3VA9241-0QE20 3VA9471-0QE20 u -- -- -- -- 3VA9133-0QF00 -- u -- -- -- 3VA9233-0QF00 -- -- u -- -- 3VA9243-0QF00 -- -- -- u -- 3VA9473-0QF00 u -- -- -- -- 3VA9134-0QF00 -- u -- -- -- 3VA9234-0QF00 -- -- u -- -- 3VA9244-0QF00 -- -- -- u -- 3VA9474-0QF00 u -- -- -- -- 3VA9131-0QF10 -- u -- -- -- 3VA9231-0QF10 -- -- u -- -- 3VA9241-0QF10 -- -- -- u -- 3VA9471-0QF10 u -- -- -- -- 3VA9131-0QF20 -- u -- -- -- 3VA9231-0QF20 -- -- u -- -- 3VA9241-0QF20 -- -- -- u -- 3VA9471-0QF20 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-97 3VA Molded Case Circuit Breakers Revised on 09/30/20 3VA Connection Technology Selection Phase barriers, terminal covers, and insulating plates For molded case circuit breakers/ rated current Type Phase barriers kit of 2 phase barriers 3VA5 125A u -- 3VA5 250A -- u 3VA6 150A 250A -- u 3VA5 3VA6 400A 600A -- -- 3VA5 3VA6 800A 1000A -- -- -- -- -- u -- Part Number 3VA9132-0WA00 3VA9272-0WA00 3VA9472-0WA00 -- -- -- -- u 3VA9672-0WA00 Terminal cover for 1-pole breakers u -- -- -- -- 3VA9131-0WD10 Terminal Cover with Probe Holes Part Number Terminal cover for 2-pole breakers u -- -- -- -- 3VA9131-0WD20 Terminal cover for 3-pole breakers Terminal cover for 4-pole breakers Terminal cover intermediate for 3-pole breakers Terminal cover intermediate for 4-pole breakers Terminal cover extended for 2-pole breakers u -- -- -- -- 3VA9131-0WD30 3VA9131-0WD31 -- u u -- -- 3VA9271-0WD30 3VA9271-0WD31 -- -- -- u -- 3VA9471-0WD30 3VA9471-0WD31 -- -- -- -- u 3VA9671-0WD30 u -- -- -- -- 3VA9131-0WD40 -- -- u -- -- 3VA9271-0WD40 -- -- -- u -- 3VA9471-0WD40 -- -- -- -- u 3VA9671-0WD40 -- -- -- -- u 3VA9671-0WE30 -- -- -- -- u 3VA9671-0WE40 u -- -- -- -- 3VA9131-0WF20 Terminal cover extended for 3-pole breakers Terminal cover extended for 4-pole breakers Terminal cover offset for 3-pole breakers u -- -- -- -- 3VA9131-0WF30 3VA9131-0WF31 -- u u -- -- 3VA9271-0WF30 3VA9271-0WF31 -- -- -- u -- 3VA9471-0WF30 3VA9471-0WF31 -- -- -- -- u 3VA9671-0WF30 u -- -- -- -- 3VA9131-0WF40 -- u u -- -- 3VA9271-0WF40 -- -- -- u -- 3VA9471-0WF40 -- -- -- -- u 3VA9671-0WF40 -- -- -- u -- 3VA9471-0WG30 Terminal cover offset for 4-pole breakers -- -- -- u -- 3VA9471-0WG40 MOLDED CASE 7 CIRCUIT BREAKERS 7-98 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA Connection Technology Phase barriers, terminal covers, and insulating plates Type Rear insulating plate extended for 2-pole breakers Revised on 05/31/19 Selection For molded case circuit breakers / rated current 3VA5 125A 3VA5 250A 3VA6 150A 250A 3VA5 3VA6 400A 600A u -- -- -- Part Number 3VA9131-0WJ20 Rear insulating plate extended for 3-pole breakers u -- -- -- 3VA9131-0WJ30 -- u u -- 3VA9271-0WJ30 -- -- -- u 3VA9471-0WJ30 Rear insulating plate extended for 4-pole breakers u -- -- -- 3VA9131-0WJ40 -- -- u -- 3VA9271-0WJ40 -- -- -- u 3VA9471-0WJ40 Rear insulating plate offset for 3-pole breakers -- -- -- u 3VA9471-0WK30 Rear insulating plate offset for 4-pole breakers -- -- -- u 3VA9471-0WK40 Control wire tap for busbar (for fixed mounting) -- u u -- 3VA9270-0WC00 -- -- -- u 3VA9470-0WC00 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-99 3VA Molded Case Circuit Breakers 3VA Plug-in and Draw-out Technology Plug-in socket Type Plug-in unit, 3-pole, complete kit Consists of: Plug-in socket, Plug-in unit, conversion kit, Mounting screw kit Revised on 10/31/18 Selection For molded case circuit breakers / rated current 3VA61/62 150A/250A u -- -- 3VA63 400A -- u -- 3VA64 600A -- -- u Part Number 3VA9143-0KP00 3VA9343-0KP00 3VA9443-0KP00 3 pole 4 pole Plug-in unit, 4-pole, complete kit Consists of: Plug-in socket, Plug-in unit, conversion kit, Mounting screw kit Plug-in unit, 3-pole, conversion kit Consists of: Screw-fastened terminal covers for molded case circuit breakers, Plug-in contacts, Cable cage, Autotrip plunger Plug-in unit, 4-pole, conversion kit Consists of: Screw-fastened terminal covers for molded case circuit breakers, Plug-in contacts, Cable cage, Autotrip plunger u -- -- 3VA9144-0KP00 -- u -- 3VA9344-0KP00 -- -- u 3VA9444-0KP00 u -- -- 3VA9143-0KP10 -- u u 3VA9343-0KP10 u -- -- 3VA9144-0KP10 -- u u 3VA9344-0KP10 3 pole 4 pole Draw-out units Type Draw-out unit, 3-pole, complete kit Consists of: Draw-out socket, Draw-out unit, conversion kit, Mounting screw kit For molded case circuit breakers / rated current 3VA61/62 3VA63 150A/250A 400A 3VA64 600A u -- -- -- u -- -- -- u Part Number 3VA9143-0KD00 3VA9343-0KD00 3VA9443-0KD00 MOLDED CASE 7 CIRCUIT BREAKERS Draw-out unit, 4-pole, complete kit Consists of: Draw-out socket, Draw-out unit, conversion kit, Mounting screw kit u -- -- 3VA9144-0KD00 -- u -- 3VA9344-0KD00 -- -- u 3VA9444-0KD00 Draw-out unit, 3-pole, conversion kit u Consists of: Screw-fastened terminal covers, -- Side wall, Plug-in contacts, Cable cage, Autotrip plunger Draw-out unit, 4-pole, conversion kit u Consists of: Screw-fastened terminal covers, -- Side wall, Plug-in contacts, Cable cage, Autotrip plunger 3 pole 4 pole Note: Crank handle for the drawout unit must be ordered seperately. -- -- 3VA9143-0KD10 u u 3VA9343-0KD10 -- -- 3VA9144-0KD10 u u 3VA9344-0KD10 7-100 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA Plug-in and Draw-out Technology Accessories Type Cable cage for plug-in/draw-out unit 3-/4pole (spare part) Cable duct for routing of the required cables from the internal acc. on the back of the breaker. Door feedthrough Autotrip plunger Plug-in unit Autotrip plunger Draw-out unit Terminal cover for plug-in/draw-out unit, 3-pole (spare part) To provide circuit breaker touch protection, for mounting on the molded case cicuit breaker Terminal cover for plug-in/draw-out unit, 4-pole (spare part) To provide circuit breaker touch protection, for mounting on the molded case cicuit breaker Crank handle for draw-out unit Insulated, including crank holder Revised on 10/31/18 Selection For molded case circuit breakers / rated current 3VA61/62 150A/250A 3VA63/64 400A/600A u -- Part Number 3VA9167-0KB02 -- u 3VA9367-0KB02 u -- 3VA9147-0KT00 -- u 3VA9347-0KT00 u -- 3VA9267-0KP81 -- u 3VA9457-0KP81 u -- 3VA9267-0KD81 -- u 3VA9457-0KD81 u -- 3VA9143-0KB01 -- u 3VA9343-0KB01 u -- 3VA9144-0KB01 -- u 3VA9344-0KB01 3VA9987-0KD81 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-101 3VA Molded Case Circuit Breakers 3VA Plug-in and Draw-out Technology Other Accessories Type Communication link for draw-out unit Consists of: Cable kit with 3 special position signaling switches, connecting cable 3VA9987-0KC10 Revised on 05/31/19 Selection Part Number 3VA9977-0KC00 Position signaling switches For draw-out unit 3VA9977-0KB00 Spare connecting cable To connect the position signaling switches for communication with the COM060 Auxiliary circuit connector n For draw-out units Auxiliary circuit connector n For plug-in units 3VA9987-0KC10 3VA9977-0KD80 3VA9977-0KP80 Cylinder lock (type Ronis) n Includes a lock with 2 keys n For locking n For installation in all rotary operators with shaft stub n For mounting in the adapter kit for the accessories component Cylinder lock adapter for draw-out unit n For fitting a cylinder lock in the right-hand side wall of the draw-out unit n To prevent unauthorized withdrawl or insertion of the circuit breaker; n Circuit breaker can be locked in the CONNECT, TEST, or DISCONNECT position 3VA9980-0VL10 3VA9980-0VL30 3VA9980-0VL40 3VA9970-0LF40 MOLDED CASE 7 CIRCUIT BREAKERS 7-102 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3V3AVUAL MMooldleddeCdasCeaCsirecuCit iBrrceaukietrBs reakers A3cVcAesCsoomrmieusnaicnatdioSnpanadreTePsatirntgs/Commissioning Devices CCoommmmunuincaictiaotnioannds toesvteinrgv/iceowmmissioning devices Design powermanager power monitoring software PROFIBUS Ethernet (Modbus TCP) PROFINET 3VA-line SIMATIC S7 T-Connector T-Connector Revised on 10/31/18 Selection powerconfig software I201_19498 4 COM800 DSP800 breaker data server display 3VA6 molded case circuit breaker 3VA6 molded case circuit breaker COM060 communication module 7KM PAC Switched Ethernet PROFINET expansion module 7KM PAC PROFIBUS DP expansion module 7KM PAC RS485 MODBUS RTU expansion module MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-103 3VA Molded Case Circuit Breakers 3VA Communication and Testing/Commissioning Devices Modules Type 24 V Module n 24 V DC n For mounting in the right-hand accessories compartment of the 3VA6 n Optional energy supply for the ETU, also includes contiunous operation of the ETU display and the metering function of the ETU 8-series COM060 communication module n For mounting in the right-hand accessories compartment of the 3VA6 molded case circuit breaker (including ETU power supply) n Communication with the COM800/COM100 breaker data server via the 3VA-line n Including a T-Connector Spare SLC adapter COM060, 24 V module accessory for: n 3VA61/62 100/150/250 Spare SLC adapter COM060, 24 V module accessory for: n 3VA63/64 400/600 Revised on 08/31/21 Selection For molded case circuit breakers / rated current 3VA61/62 150A/250 A 3VA63/64/65/66 400A/600A 800A/1000A u -- -- u Part Number 3VA9177-0TB50 3VA9377-0TB50 u -- 3VA9177-0TB10 -- u 3VA9377-0TB10 u -- 3VA9187-0TB60 -- u 3VA9387-0TB60 Breaker data server Type COM800 breaker data server n 2 terminating resistors n Central communication module for connecting up to eight 3VA6 molded case circuit breakers via the 3VA-line n Ethernet 10/100 Mbit/s interface n Communication via Ethernet (Modbus TCP) n Module slot for plugging on an optional PROFIBUS DP, PROFINET or RS485 module COM100 breaker data server n 2 terminating resistors n Central communication module for connecting one 3VA6 molded case circuit breaker n Ethernet 10/100 Mbit/s interface n Communication via Ethernet (Modbus TCP) n Module slot for plugging on an optional PROFIBUS DP, PROFINET or RS485 module 7KM PAC PROFIBUS DP expansion module n The 7KM PAC PROFIBUS DP expansion module is used for connecting the COM800/COM100 breaker data server, and the 3VA molded case circuit breakers conneccted to it, to PROFIBUS DPV1 n The 7KM PAC PROFIBUS DP expansion module provides the status and measured quantities of the 3VA molded case circuit breaker for the PROFIBUS DP master. It receives information (e.g. commands) from the PROFIBUS DP master, and forwards this information to the 3VA molded case circuit breaker 7KM PAC Switched Ethernet PROFINET expansion module n The 7KM PAC Switched Ethernet PROFINET expansion module is used to connect the COM800/COM100 breaker data server, and the connected 3VA molded case circuit breaker, to PROFINET via two Ethernet interfaces n The 7KM PAC Switched Ethernet PROFINET expansion module provides the status and measured quantities of the 3VA molded case circuit breaker to PROFINET via the PROFINET IO, PROFIenergy and Modbus TCP protocols Part Number 3VA9977-0TA10 3VA9977-0TA20 7KM9300-0AB01-0AA0 7KM9300-0AE01-0AA0 7KM PAC RS485 Modbus RTU expansion module n The 7KM PAC RS485 Modbus expansion module is used to connect the COM800/ COM100 breaker data server, and the 3VA molded case circuit breaker connected to it, to Modbus RTU n The 7KM PAC RS485 Modbus expansion module provides the status and measured quantities of the 3VA molded case circuit breaker for the Modbus RTU master. It receives information (e.g. commands) from the Modbus RTU master, and forwards this information to the 3VA molded case circuit breaker 7KM9300-0AM00-0AA0 MOLDED CASE 7 CIRCUIT BREAKERS 7-104 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA Communication and Testing/Commissioning Devices Accessories for Communication Type T-Connector n Spare part n Provides spur line feeder to COM060 and loops to the nextcircuit breaker n Includes a connection adapter for mounting on the 3VA6 breaker enclosure DIN rail adapter For snapping the T-Connector onto a DIN rail Preassembled T-Connector-to-T-Connector or T-Connector-to-COM800/ COM100 connecting cable n 0.4 m long n 1 m long n 2 m long n 4 m long Preassembled connecting cable for extending the COM060-to-T-Connector spur line connection n 0.4 m long n 0.8 m long Additional bus terminating resistors Revised on 04/30/20 Selection Part Number 3VA9987-0TG10 3VA9987-0TG11 3VA9987-0TC10 3VA9987-0TC20 3VA9987-0TC30 3VA9987-0TC40 3VA9987-0TF20 3VA9987-0TF10 3VA9987-0TE10 MOLDED CASE 7 CIRCUIT BREAKERS Voltage tap to external N conductor Cable for connecting the neutral point for the metering function of the 8-Series ETU, length 1.5 m 3VA9987-0UC10 External current transformer as straight-through transformer. Connection of an external current transformer for the N conductor for 3-pole 3VA6 molded case circuit breakers for 5-series and 8-series ETUs (ETU850, ETU856, ETU860), including connecting cable n In = 25 ... 150A n In = 160 ... 350 A n In = 400 ... 630 A n In = 600 ... 1000 A DSP800 display n For displaying the status, measured values and parameters of up to 8 3VA6 molded cases circuit breakers n Connection to the COM800/COM100 via Ethernet for displaying information of the COM800/COM100 and the connected 3VA6 molded case circuit breaker 3VA9077-0NA10 3VA9177-0NA10 3VA9377-0NA10 3VA9677-0NA10 3VA9977-0TD10 EFB300 n External function box for connection to the ETU of the 3VA6 molded case circuit breaker n 4 digital outputs for information output, 1 digital input n ZSI functionality n S0 interface n Including cable 1.5 m in length 3VA9977-0UA10 Connecting cable for EFB300 and MMB300. Spare part n 1.5 m long n 3.0 m long n 3.0 m long for 3VA with EFB and RCD820 3VA9987-0UB10 3VA9987-0UB20 3VA9987-0UB30 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-105 3VA Molded Case Circuit Breakers 3VA Communication and Testing/Commissioning Devices Test devices Type TD300 n Connection to the front interface of the ETU n Test device for activating the ETU and triggering a test trip Revised on 02/28/19 Selection Part Number 3VA9977-0MA10 MOLDED CASE 7 CIRCUIT BREAKERS TD500 n Connection to the front interface of the ETU n Initiation of various test trips (LSING) n USB interface for connection of a PC using powerconfig n ETU parameterization n Including external power supply unit with adapter for Europe, UL and GB n Including connecting cable to the 3VA6 molded case circuit breaker Spare part: External power supply for TD500 110 ... 240 V AC 3VA9977-0MB10 3VA9987-0MX10 Spare part: Cable for connecting to the TD500 to the 3VA6 molded case circuit breaker Maintenance Mode Box MMB300 n Realization of the NEC 240.87 (Arc Energy Reduction) -> personal protection during maintenance work n Switch into maintenance mode by changing the I- and G-protection to the lowest possible value through an external signal (e.g. door contact) n Available for all 3VA6 circuit breakers with electronic trip unit n Daisy chain up to 8 circuit breakers equipped with MMB300 n Additional digital output (D01) for ETU signals available n Capable of DIN rail mounting n Includes cable 1.5m in length 3VA9977-0MY10 3VA9977-0UF10 7-106 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA Accessories for Locking, Blocking and Interlocking Locking, Blocking, & Interlocking Type Blocking device for the handle Revised on 06/30/21 Selection For molded case circuit breakers/ rated current 3VA4 125A -- 3VA5 125A u 3VA5 250A -- 3VA6 150A 250A -- 3VA5 3VA6 400A 600A -- -- -- u u u 3VA5 3VA6 800A 1000A Part Number -- 3VA9038-0LB10 -- 3VA9378-0LB10 3VA51 Padlock device for the handle 3VA5/3VA6 2 pole 3VA4 3 pole 3VA4 Handle tie & padlock 2-inch 3VA4 Handle tie & padlock 3-inch u -- -- -- -- -- 3VA9038-0LB11 -- -- u u -- -- 3VA9138-0LB11 -- -- -- -- u -- 3VA9338-0LB11 -- -- -- -- -- u 3VA9578-0LB10 u -- -- -- -- -- 3VA9032-0LB20 u -- -- -- -- -- 3VA9033-0LB20 Adapter kit for mounting the cylinder lock (type -- u -- -- -- -- 3VA9137-0LF10 Ronis) in the accessories compartment of the molded case circuit breaker Comprising 2 cylinder -- -- u -- -- -- 3VA9237-0LF10 lock casings (one for locking and one for interlock- -- -- -- u -- -- 3VA9147-0LF10 ing) and the appropriate mounting module n To implement an interlock or a lock: select suitable cylinder lock(s) -- -- -- -- u -- 3VA9347-0LF10 -- -- -- -- -- u 3VA9577-0LF10 n For an interlock: select the same cylinder lock number Cylinder lock (type Ronis) n Includes a lock with 2 keys n For locking or interlocking n For installation in all rotary operators with shaft stub n For mounting in the adapter kit for the accessories compartment n Key 1 (lock number 1) n Key 3 (lock number 3) n Key 4 (lock number 4) Sliding bar Complete kit for interlocking 2 circuit breakers n The article number must be ordered 2X to implement an interlock between 3 breakers of the same size -- u u u u -- 3VA9980-0VL10 -- u u u u -- 3VA9980-0VL30 -- u u u u -- 3VA9980-0VL40 -- u -- -- -- -- 3VA9138-0VF30 -- -- u -- -- -- 3VA9238-0VF30 -- -- -- u -- -- 3VA9148-0VF30 -- -- -- -- u -- 3VA9348-0VF30 Module for handle interlock using a bowden cable -- u -- -- -- -- 3VA9137-0VF10 n A separate handle interlock module is required for each switching device n A Bowden cable must be ordered separately -- -- u -- -- -- 3VA9237-0VF10 -- -- -- u -- -- 3VA9147-0VF10 -- -- -- -- u -- 3VA9347-0VF10 -- -- -- -- -- u 3VA9577-0VF10 Rear interlock with rod Complete Kit n Mounting frames are not included in scope of supply -- u u u u -- 3VA9078-0VM10 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-107 3VA Molded Case Circuit Breakers Revised on 05/31/21 3VA Accessories for Locking, Blocking and Interlocking Selection Locking, Blocking, & Interlocking Type Rear interlock with rod Complete Kit n Mounting frames are included in scope of supply For molded case circuit breakers/ rated current 3VA5 125A -- 3VA5 250A -- 3VA6 150A 250A -- 3VA5 3VA6 400A 600A -- 3VA5 3VA6 800A 1000A u Part Number 3VA9578-0VM10 Rear interlock with rod u u u u -- 3VA9078-0VM30 Complete Kit for plug-in/draw-out unit n Mounting frames are not included in scope of supply Bowden cable n Length 0.6 m n Length 1.0 m n Length 1.5 m Mounting frame for rear interlock with rodab The following are required for the complete mounting frame kit: n Profile poles n Mounting Plates u u u u u 3VA9980-0VC10 u u u u u 3VA9980-0VC20 u u u u u 3VA9980-0VC30 u u u u -- 3VA9078-0VK10 u -- -- -- -- 3VA9138-0VK20 -- u -- -- -- 3VA9238-0VK20 -- -- u -- -- 3VA9248-0VK20 -- -- -- u -- 3VA9448-0VK20 Cover frame for door cut-out Cover frame for door cut-out for molded case circuit breaker n 3-pole, door cut-out without trip unit Cover frame for door cut-out for molded case circuit breaker n 3-pole, door cut-out with trip unit Cover frame for door cut-out for molded case circuit breaker n 4-pole, door cut-out without trip unit Cover frame for door cut-out for molded case circuit breaker n 4-pole, door cut-out with trip unit Cover frame for door cut-out for MO320 motor operators Cover frame for door cut-out for front mounted rotary operators Cover frame for door cut-out for front mounted rotary operator with door interlock Cover frame for door cut-out for door feedthrough Labeling plate for cover frame u -- -- -- -- 3VA9033-0SB10 -- u u -- -- 3VA9143-0SB10 -- -- -- u -- 3VA9373-0SB10 -- -- -- -- u 3VA9583-0SB10 u -- -- -- -- 3VA9033-0SB20 -- u -- -- -- 3VA9233-0SB20 -- -- u -- -- 3VA9143-0SB20 -- -- -- u -- 3VA9343-0SB20 -- -- -- -- u 3VA9583-0SB20 u -- -- -- -- 3VA9034-0SB10 -- u u -- -- 3VA9144-0SB10 -- -- -- u -- 3VA9374-0SB10 -- -- -- -- u 3VA9584-0SB10 u -- -- -- -- 3VA9034-0SB20 -- u -- -- -- 3VA9234-0SB20 -- -- u -- -- 3VA9144-0SB20 -- -- -- u -- 3VA9344-0SB20 -- -- -- -- u 3VA9584-0SB20 u -- -- -- -- 3VA9033-0SB10 -- u u -- -- 3VA9237-0SB30 -- -- -- u -- 3VA9377-0SB30 u -- -- -- -- 3VA9033-0SB10 -- u u -- -- 3VA9143-0SB10 -- -- -- u -- 3VA9373-0SB10 -- -- -- u -- 3VA9377-0SB30 -- -- -- -- u 3VA9583-0SB50 -- u u -- -- 3VA9233-0SB20 -- -- -- u -- 3VA9333-0SB20 3VA9087-0SX10 MOLDED CASE 7 CIRCUIT BREAKERS a 2 mounting plates are required. They are screwed onto the profile rail that can be ordered above. Different breakers can be mutually interlocked. b Breakers with plug-in unit can be mounted on the mounting plates, but the profile rails cannot be used. 7-108 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers 3VA Accessories and Spare Parts Other accessories Type Busbar adapter system with 60 mm busbar center-to-center spacing 3-pole Revised on 07/31/21 Selection For molded case circuit breakers/ rated current 3VA5 125A 3VA5 250A 3VA6 150A 250A 3VA5 3VA6 400A 600A 3VA5 3VA6 800A 1000A u -- -- -- -- -- u u -- -- -- -- -- u -- Part Number 8US1211-4SS00a 8US1213-4AP03b 8US1213-4AH04b MOLDED CASE 7 CIRCUIT BREAKERS Busbar adapter system with 60 mm busbar center to center spacing, bottom connection, 3-pole Busbar adapter designed for 3VA breaker used as a main u -- -- -- -- 8US1215-4SS00 Metric mounting screw kit For fixed mounted breakers 1-pole Metric mounting screw kit (2 pcs) For fixed mounted breakers 2-pole Metric mounting screw kit (4 pcs) For fixed mounted breakers 3-,4-pole Metric mounting screw kit For fixed mounted breakers 3-pole Metric mounting screw kit For fixed mounted breakers 4-pole Metric mounting screw kit For fixed mounted breakers 3-,4-pole Metric mounting screw kit For plug-in and draw-out unit SAE mounting screw kit (2 pcs) For fixed mounted breakers 1-pole SAE Mounting screw kit (2 pcs) For fixed mounted breakers 2-,3-pole SAE Mounting screw kit (4 pcs) For fixed mounting breakers 4-pole SAE Mounting screw kit (4 pcs) For fixed mounted breakers 3-,4-pole and 3VA6 150/250 plug-in and draw-out units SAE Mounting screw kit (2 pcs) For fixed mounted breakers 2-,3-pole SAE Mounting screw kit (4 pcs) For fixed mounted breakers 2-,3-,4-pole and 3VA6 400/600 plug-in and draw-out units Replacement handle extension accessory u -- -- -- -- 3VA9151-0SS10 u -- -- -- -- 3VA9116-0SS10 u u -- -- -- 3VA9114-0SS10 -- -- u -- -- 3VA9126-0SS10 -- -- u -- -- 3VA9124-0SS10 -- -- -- u -- 3VA9328-0SS10 -- -- u -- -- 3VA9124-0SS10 u -- -- -- -- 3VA9151-0SS00 u -- -- -- -- 3VA9156-0SS00 u -- -- -- -- 3VA9154-0SS00 -- u u -- -- 3VA9164-0SS00 -- u u -- -- 3VA9166-0SS00 -- -- -- u -- 3VA9368-0SS00 -- -- -- u -- 3VA9487-0SC10 Replacement handle extension accessory -- -- -- -- u 3VA9987-0SC10 a Busbar adapter designed for 3VA breaker used as a feeder. b Busbar adapter designed for 3VA breaker used as either a main or feeder. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-109 3VA Molded Case Circuit Breakers 3VA Accessory Electrical Requirements Auxiliary switches electrical requirements Auxiliary switches and alarm switches HQ Revised on 10/31/18 Technical data Internal accessories Auxiliary switches and alarm Auxiliary switches and switches HQ_electronic alarm switches HP AUX LCS TAS EAS AUX LCS TAS EAS AUX LCS TAS Rated Ue V AC 240 24 600 operational 50 Hz voltage V DC 250 24 250 Conventional free-air thermal current IEC Ratings Listed AC-12 Ith = Ie A 6 12 V 24 V 48 V A 6 A 6 A 6 0.3 10 0.3 10 0.3 10 -- 10 125 V A 6 -- 10 220/240 V A 6 -- 10 380/440 V A -- -- 6 600 V A -- -- 2 AC-15 12 V A 3 2/4 V A 3 48 V A 3 0.3 6 0.3 6 -- 6 125 V A 3 -- 6 220/240 V A 3 -- 6 380/440 V A -- -- 2 600 V A -- -- 0.6 DC-12 12 V 24 V A 6 A 4 0.1 6 0.1 6 48 V A 2 -- 2 110 V A 0.5 -- 0.6 250 V A 0.25 -- 0.3 DC-13 12 V A 1 0.07 3 24 V A 0.8 0.07 3 48 V A 0.4 -- 0.8 110 V A 0.2 -- 0.2 250 V A 0.1 -- 0.1 Max. rated Inductive load current (UL/CSA) (0.75-0.8 AC) 24 V A 3 300 V A 3 600 V A -- 0.3 6 -- 6 -- 6 Pilot duty (AC) 24 V A 3 -- 6 127 V A 3 -- 6 240 V A 3 -- 3 480 V A -- -- 1.5 600 V A -- -- 1.2 Resistive load (DC) 24 V A 0.25 0.1 0.3 250 V A 0.25 -- 0.3 Resistive load - pilot 125 V A 0.6 -- 0.9 duty sequence (DC) 250 V A 0.3 -- 0.55 Minimum load At 24 mA 70 0.5 70 V DC At 5 V DC mA -- 1 -- MOLDED CASE 7 CIRCUIT BREAKERS 7-110 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 3VA Molded Case Circuit Breakers Revised on 10/15/20 3VA Accessory Electrical Requirements Technical data Shunt trip/undervoltage electrical requirements Shunt trip left STL Shunt trip flexible STF Undervoltage Universal releases UVR release UNI MOLDED CASE 7 CIRCUIT BREAKERS Power consumption Ue 12 24 24 ... 30 48 ... 60 48 ... 60 110 ... 127 110 ... 127 208 ... 277 220 ... 250 380 ... 600 24 48 ... 60 110 ... 127 208 ... 277 380 ... 500 600 12 ... 250 V DC W 50 V AC/60 Hz VA V DC W 50 V AC/60 Hz VA V DC W 50 V AC/60 Hz VA V DC W 50 V AC/60 Hz VA V DC W 50 V AC/60 Hz VA 50 V AC/60 Hz VA 50 V AC/60 Hz VA 50 V AC/60 Hz VA 50 V AC/60 Hz VA 50 V AC/60 Hz VA 50 V AC/60 Hz VA V DC W 24 ... 230 50 V AC/60 Hz VA 380 ... 480 50 V AC/60 Hz VA 12 V DC (Cat II; W PELV/SELV) 24 V DC (Cat II; W PELV/SELV) 48 V DC (Cat II; W PELV/SELV) Rated impulse withstand voltage Making current Maximum tripping time Service life Uimp kV Imax at V ms Electrical trips Mechanical switching cycles of the circuit breaker Priority over other control signals Degree of protection Lid of the accessories compartment closed Lid of the accessories compartment open Minimum signal duration ms Response voltage shunt Pick-up (circuit Us/V % trip breaker trips) Undervoltage release Pick-up (circuit Us/V % response voltage breaker can be switched on) Pick-up (circuit Us/V % breaker trips) Tripping frequency Trips per hour Can be used for electrical interlocking of molded case circuit breakers 50 50 7 ... 50 15 ... 20 20 ... 30 30 ... 40 30 ... 40 16 ... 35 28 ... 35 10 ... 30 ----------- -- -- 6 1.5 A/24 V AC < 10 8500 25000 Given IP40 IP 20 40 70 ... 110 -- -- Unlimited No ----------300 340 ... 600 500 ... 650 360 ... 650 330 ... 600 300 ------- 18 A/24 V AC 40 -- -120 No ----------------< 2.5 < 2 < 2.5 -- -- -- 4 5 mA/480 V --- 85 ... 110 35 ... 70 Unlimited Yes -------------------UVR: < 2.5 SHT: 20 UVR: < 2.5 SHT: 20 UVR: < 2.5 SHT: 20 0.5 1.5 A/24 V 40 70 ... 110 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-111 s (e.g. nually, urpose. ther the dentify r at any ode, the tically l before quick visual overview and prevents operating errors indicator which indicates ON and OFF and, via LED, whether the · Locking capability prevents unauthorized operations circuit breaker has tripped (TRIP). It is thus possible to identify Design 3VA Molded Case Circuit Breakers · Even with a mounted MO320 the 3VA still meets the stantdhaerdsswitching for isolating characteristics defined by IEC / EN 60947-t1ime. position of the molded case circuit bRreevaikseerdaot ann1y0/31·/2T0he MO320 mo a mounting fram Two different reset modes can be selected, i.e. in one mode, the lid of the molde Design operator resets the molded case circuit breaker automatically · 3TaVhmeAoMuAOnct3icn2eg0sfsmraoomrtyoerEtohlpeaect rtiasrtiiocnrasiltsaRslleiemdqpuinlyisrsetenmaadpepnoeftsdthientaocpcoessistaiitoonrrniedeossinenttshtehoethberer,aikt wera. its for confirmation by an OFF signal bTeefcohrenical Tdeactahnical specif lid of the molded case circuit breaker. Motor Technical operator electrical specifications requiremeFOunFrFtthspeormsiotioren, the motor by means operator can be locked of several padlocks. in the MO320 motor opera MO320 motor operator 3VA5 3VA5 3VA6 125 A 250 A 150 A/ 250 A Degree of protection NEMA 1 Rated control supply voltage 24 V ... 60 V DC (0.85 ... 1.26) (operating range of control supply voltage) 110 V ... 230 V AC/ 110 V ... 250 V DC (0.85 ... 1.1) Rating 250 W, max. 500 W (60 ms) Make time, typically < 800 ms < 1000 ms Break time, typically < 800 ms < 1000 ms 3VA5 3VA6 400 A/ 600 A < 1700 ms < 1400 ms Degree of protection Rated control supply (operating range of c supply voltage) Rating Make time, typically Break time, typically DC breaking capacity according to UL489 3VA51 125 A (15- 125 A) 3VA52 250 A (40 250 A) 4 3VA53 400 A (200 - 400 A) DC single-pole 3VA54 disconnection 600 ASelection and ordering data (450 600 A) Groundeda For molded case circuit breakers/ S M DC breaking capacity acc. UL489 in kA DT Article No. Price PE PS*/ PG H M H C M perHPU (UCNIT, PM. unit H C rated current SET, 3VA5 3VA5 1235VAV6 3VA6 250 V 250 V M) 250 V Version 125 A 250 A 150 A, 400 A, 250 A 600 A DC all-pole disconnection Groundeda Isolated For molded case circuit DT breakers/ rated current 3VA5 3VA5 3VA6 3VA6 125 A 250 A 150 A, 400 A, 250 A 600 A y feature -- -- -- -- -- -- -- -- 14 25 30 50 85 100 50 85 25-0- V --- -- -- -- -- -- 50 85 100 5030VVA9137-0HA10 3VA9277-0HA10 3VA9447-0HA10 3VA9137-0HA20 3VA9277-0HA20 3VA9447-0HA20 500 V 50 85 100 50 85 100 LoLaModoadtor oLpoeardatorsLoLaodad LoLaodad LLooaadd LLooaadd 50 85 100 LLooaadM(dMoOto3r20o)pLLeoroaaatdodrs Load LoLaodad withLLoouoatadsdtoredLLeoonaaeddrgy feaLtuoLrLLaeooodaaaddd Load LoLaodad LLooaadd LLooaa 1 5100unVit 1CB 1 1 unit 1CB 1 1 unit 1CB 1 1 unit 1CB Versions · 24 ... 60bV DC -- -- -- -- -- -- -- -- 1 1 1 1 uunnLii3ttoLVLLaA11ooodCC9aaaBB2ddd77-0HLoALa1Lo0doaadd LoLaLoLdoao·daa11dd1100 ... ... 22L53o00LLLaoVVoodaaaDAdddCC, Load LoLaodad LLooaadd LLooaadd-- 100 50 85 100 -- LoLLLaoo--od--aaadddGFGGGFFF--L--oLaLodoaaddG----FLGGoFFLaLoLdoaodaaG 500 V 750 V 600 V 600 V MOLDED CASE 7 CIRCUIT BREAKERS 50 85 100 50 85 100 750 V 50 85 100 50 85 100 6 6 600 V 1000 V 750 V 750 V LoLaodad Load LoLaodad 10 6 6 LLoo1aa0dd LLooaadd LLooaadd 750 V LoLaodad LLooaadd Load LLooaadd LoLaodad LLooaadd LoLLLaooodaaadddGFGGFLF oLaLodoaaddGFLoGLFaLoLdoao GF GF 50 85 100 50 85 100 -- 1000 V 50 85 100 50 85 100 6 6 1000 V 10 6 6 LoLaodad Load LoLaodad 10LLooaadd LLooaadd LLooaadd LoLLLaooodaaadddGFGGFLF oLaLodoaaddGFLoG GF GF Applies to MCCBs in line protection and MCS (if protected by4a/20 suitable overcurrent protection device). With an non-grounded system, all poles must disconnect such that the load is isolated when switched off. SieTmheengsro·u0n4d/e2d01p7ole must always be assigned to the individual conducting path, so that in the event of a ground fault there are always 2 conducting paths in series in a circuit with 3-pole molded case circuit breakers, and 3 conducting paths in series in a circuit with 4-pole molded case circuit breakers. GF ground fault monitoring a Minus pole grounded b Also covers 1-pole circuit breaker in 2-pole frame Additional wiring configurations are available on request. 7-112 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Sentron Molded Case Circuit Breakers Catalog Numbering System If used on 250A frame and above means non-interchangeable trip breaker with factory assembled frame and trip. Solid state trip and current limiting (S or C in first character) are non-interchangeable only, and the "X" is omitted. XD Trip Unit Type -- Omitted Thermal-Magnetic S -- Sensitrip® Electronic Trip Sentron Series Type/Interrupting Range -- Omitted Standard Rating H -- High IC Rating HH -- Extra High IC Rating C -- Highest IC Rating and Current Limiting Frame Identifier E -- Type ED F -- Type FD J -- Type JD L -- Type LD LM -- Type LMD M -- Type MD N -- Type ND P -- Type PD R -- Type RD Maximum Voltage 2 -- 240 Vac 4 -- 480 Vac 6 -- 600 Vac Number of Poles 1 2 3 A -- used to indicate advanced electronic trip unit with maintenance mode capability (always 3 poles) B -- used to indicate basic electronic trip unit (always 3 poles) (Specific Application Type) B -- Standard 40°C Breaker M -- Calibrated for 50°C Application F -- Frame Only T -- 40°C Trip Unit Only W -- 50°C Trip Unit Only S -- Molded Case Switch L -- Low Instantaneous Range ETI Breaker A -- Standard Range ETIBreaker H -- High Instantaneous Range ETI Breaker Maximum Continuous Current Rating ED Frame -- 015, 020, 025, 030, 035, 040, 045, 050, 060, 070, 080, 090, 100, 110, 125 FD Frame -- 070, 080, 090, 100, 110, 125, 150, 175, 200, 225, 250 JD Frame -- 200, 225, 250, 300, 350, 400 LD Frame -- 250, 300, 350, 400, 450, 500, 600 LMD Frame -- 500, 600, 700, 800 MD Frame -- 500, 600, 700, 800 ND Frame -- 900, 100 (1000A), 120 (1200A) PD Frame -- 120 (1200A), 140 (1400A), 160 (1600A) RD Frame -- 160 (1600A), 180 (1800A), 200 (2000A) Suffix L -- where applicable indicates a breaker shipped with line/loads lugs installed A -- used with a switch to show automatic self protection Y -- 400 Hertz H -- 100% rated P -- Load side lugs only NAV -- Naval Ratings NOTE: -- Position omitted if not used. Revised on 02/06/18 Selection/Application MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-113 Molded Case Circuit Breakers Revised on 06/30/19 ED 125A Frame Sentron Series Selection Ordering Instructions A ll ED Frame Sentron circuit breakers are supplied with load side lugs. If line side lugs are required, add "L" suffix to catalog number. Consult Siemens sales office for any addditional charge 50°C Calibration, 400HZ - see page 7-159. All ED frame circuit breakers may be reverse connected Type ED2e Continuous Current Rating @ 40° C 015 020 25 030 35 040 45 050 060 070 80 90 100 1-Pole 120V AC 125V DC Catalog Number ED21B015dn ED21B020dn ED21B025n ED21B030n ED21B035n ED21B040n ED21B045n ED21B050n ED21B060n ED21B070n ED21B080n ED21B090n ED21B100n 2-Pole 240V AC 125V DC 250V DC Catalog Number ED22B015 ED22B020 ED22B025n ED22B030 ED22B035n ED22B040 ED22B045n ED22B050 ED22B060 ED22B070 ED22B080n ED22B090n ED22B100 Blue Label 3-Pole 240V AC Catalog Number ED23B015 ED23B020 ED23B025n ED23B030 ED23B035n ED23B040 ED23B045n ED23B050 ED23B060 ED23B070 ED23B080 ED23B090n ED23B100 Type ED4e Continuous Current Rating @ 40° C 015 020 025 030 035 040 045 050 060 070 080 090 100 110 125 1-Pole 120V AC 277V AC 125V DC Catalog Number ED41B015d ED41B020d ED41B025 ED41B030 ED41B035n ED41B040 ED41B045n ED41B050 ED41B060 ED41B070 ED41B080n ED41B090n ED41B100 ED41B110 -- 2-Pole 480V AC 250V DC Catalog Number -- ED42B020 ED42B025 ED42B030 ED42B035n ED42B040 ED42B045n ED42B050 ED42B060 ED42B070 ED42B080n ED42B090n ED42B100 ED42B110n ED42B125 Blue Label 3-Pole 480V AC Catalog Number ED43B015 ED43B020 ED43B025 ED43B030 ED43B035 ED43B040 ED43B045 ED43B050 ED43B060 ED43B070 ED43B080 ED43B090 ED43B100 ED43B110 ED43B125 Type ED6e Blue Label Continuous Current Rating @ 40° C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 1-Pole 347V AC Catalog Number ED61B015 ED61B020 ED61B025 ED61B030 ED61B035 ED61B040 ED61B045n ED61B050 ED61B060 ED61B070n ED61B080 ED61B090 ED61B100n -- -- 2-Pole 3-Pole 3-Pole 600V AC 250V DC 600V AC 500V DC 600V DC Catalog Number -- ED62B020 ED62B025n ED62B030 -- -- -- -- -- -- -- -- -- -- -- Catalog Number -- ED63B020 ED63B025 ED63B030 ED63B035 ED63B040 ED63B045 ED63B050 ED63B060 ED63B070 ED63B080 ED63B090 ED63B100 ED63B110 ED63B125 Catalog Number ED63D015L ED63D020L ED63D025L ED63D030L ED63D035L ED63D040L ED63D045L ED63D050L ED63D060L -- -- -- -- -- -- Note: ED frame circuit breakers qualified to UL 489 Supplement SB "Naval"-- See page 7-159 for additional information n Built to order. Allow 23 weeks for delivery. aCSA Certified only (Not UL) bFor CED types and all 110125 ampere ED frames. cSee Note: A, page 7-156. dSWD rated. e HACR rated. Not for use with HHED6 breakers. Shipping Weights Number of Poles Number per Carton ED2, ED4, ED6, HED4, HHED6 1 30 2 10 3 10 CED6 2 5 3 5 Shipping Weight (lbs.) 38 25 38 20 30 Lugs Ampere Rating No. of Catalog Poles Number Aluminum Body Lugs All 1525A 1, 2, 3 Line/Load SA1E025 All 30100A 1, 2, 3 Line Side LN1E100 Wire Range #14#10 Cu #12#10 Al #101/0 Cu/Al ED2, 4, 6, HED4 30-60A 1 Load Side LD1E060 #10#4 Cu/Al ED2, 4, 6, HED4 70-100A 1 ED2, 4, 6, HED4, HHED6 2, 3 30-100A All 110, 125A 2, 3 Copper Body Lugs All 30125A 1, 2, 3 Compression Lugs All ED, HED, HHED, CED Load Side LD1E100 Load Side LN1E100 Line/Load TA1E6125 #6#1/0 Cu/Al #101/0 Cu/Al #33/0 Cu #12/0 Al Line/Load #101/0 Cu TC1ED6150c only CCE125 2/0 Enclosures (Neutral Included) Type 1 (Surface) 1 (Flush) 3R 44X 79 79 12 1 (Surface) 1 (Flush) 3R 12 Catalog Number E2N1S (15100A) E2N1F (15100A) E2N3R (15100A) ED6SS4 (15125A) EA (1560A) EB (70100A) E2N12 (15100A) CED6N1S b CED6N1F b CED6N3R b CED6N12 b Modifications page 7-159 Enclosures Section 6 Accessories pages 7-116 and 7-163 to 7-168 7-114 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers Revised on 07/31/19 ED 125A Frame Sentron Series Selection/Dimensions Type HED4 Black Label FIGURE1 - ED, HED, HHED Continuous Current Rating @ 40° C 015 020 25 030 35 040 45 050 060 070 80 90 100 110 125 1-Pole 277V AC 125V DC Catalog Number HED41B015a HED41B020a HED41B025 HED41B030 HED41B035n HED41B040 HED41B045n HED41B050n HED41B060n HED41B070n HED41B080n HED41B090n HED41B100n -- -- 2-Pole 480V AC 250V DC Catalog Number HED42B015 HED42B020 HED42B025n HED42B030 HED42B035n HED42B040 HED42B045n HED42B050 HED42B060n HED42B070n HED42B080n HED42B090n HED42B100n HED42B110n HED42B125n 3-Pole 480V AC Catalog Number HED43B015 HED43B020 HED43B025 HED43B030 HED43B035 HED43B040 HED43B045 HED43B050 HED43B060 HED43B070 HED43B080 HED43B090 HED43B100 HED43B110 HED43B125 D D1 H W1 1-POLE W2 2-POLE W3 3-POLE FIGURE 2 - CED (3-Pole shown) D Fuseless Current Limiting Type HHED6 Black Label Type CED6 Red Label D1 H Continuous Current Rating @ 40°C 015 020 025 030 035 040 045 050 060 070 080 090 100 110 125 3-Pole 600V AC Catalog Number HHED63B015A HHED63B020 HHED63B025 HHED63B030 HHED63B035 HHED63B040 HHED63B045 HHED63B050 -- -- -- -- -- -- -- 2-Pole 600V AC, 250V DC Catalog Number CED62B015 CED62B020n -- CED62B030n -- -- -- -- CED62B060n CED62B070n CED62B080n CED62B090n CED62B100n -- CED62B125n 3-Pole 600V AC, 500V DCb Catalog Number CED63B015 CED63B020 -- CED63B030 -- CED63B040 -- CED63B050 CED63B060 CED63B070 CED63B080 CED63B090 CED63B100 CED63B110n CED63B125 W2, W3 Dimensions (in inches) Breaker Type W1 W2 W3 H D D1 Figure 1 ED2, ED4, ED6, HED4, 1 23 6.35 3.92 4.56 ED6 ETIc Figure 1 HHED6 -- 2 3 6.53 3.92 4.56 Figure 2 CED6, CED6 ETIc -- 2 3 9.58 3.92 4.56 Interrupting Ratings Breaker Type ED2 (1-P) ED2 (2, 3-P) ED4 (1-P) ED4 (2, 3-P) ED6 (1P) ED6 (2, 3-P) ED6 (3-P) HED4 (1-P) (1530A) HED4 (1-P) (35100A) HED4 (2, 3-P) HHED6 (2, 3-P) CED6 (2, 3-P) UL 489 AIR (File #E10848) IEC 947-2 RMS Symmetrical Amperes (KA) Volts AC (50/60Hz) Volts AC Volts DC 220/240 380/415 500 120 240 277 347 480 600 125 250 500 600 lcu lcs lcu lcs lcu lcs 10 -- -- 10 65 -- -- 65 -- -- -- 65 -- -- ---- -- -- ---- -- -- 22 -- -- -- ---- 18 -- -- 30 -- -- -- -- 25 18 ---- -- -- 5 -- -- -- -- -- -- -- -- -- -- 5 (2-P) -- -- -- -- -- -- -- -- 30 -- -- -- -- -- -- -- -- -- -- 30 (2-P) -- -- -- -- -- -- -- -- -- 30 -- -- -- -- -- -- -- -- -- -- 18 (3-P) -- 65 17 35 9 18 5 -- -- -- 10g -- -- -- -- -- -- 100 -- 65 -- -- -- 30 -- -- -- -- -- -- -- -- -- 100 -- -- 100 -- 100 -- 200 25 -- -- -- ---- 42 -- ---- 65 18 -- -- 200 100 30 -- -- -- 30 (2-P) -- -- -- -- -- 50 (2-P) 30 (3-P) -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- n Built to order. Allow 23 weeks for delivery. aSWD rated. bWhen wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems. c ED6-ETI, CED6-ETI, see page 7-143 for ordering information. dSingle Pole 15-30A 30KA @ 347V non-UL. 35-100A 18KA @ 347V non-UL. eHACR rated. f HHED63B015A is rated 18KAIC at 600/347V. g 600VDC only applies to ED63D___ breakers MOLDED CASE 7 CIRCUIT BREAKERS Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-115 Molded Case Circuit Breakers Revised on 12/31/19 Accessories Accessories for: ED 125A Frame Combinations Available only when ordered together. Only one module can be added to a breaker. Additional accessories, which always attach to the left pole, cannot be added to the combination later. Adds 1 inch pole space. Equipment Ground Sensing A field addable kit containing 30mA or 5 mA ground fault accessory module, current transformer with 24 inch leads, and current transformer mounting equipment. Current transformer to mount in gutter of lighting panel or any control panel. Accessory module operates from separate 120V control power source. Both 30MA and 5MA devices are equipment protection devices only. Do not use for personnel protection. Selection Shunt Trip Combinations Control Voltage AC DC 024 048 120 208 240 277 480 012 024 048 125 250 1 Shunt Trip Catalog Number S17ED60 S18ED60 S01ED60 -- S03ED60 S15ED60s S04ED60 S16ED60s S07ED60 S09ED60s S11ED60s S13ED60s 1 Shunt Trip 1 Shunt Trip and 1 Auxiliary Switch 1 Shunt Trip and 1 Auxiliary Switch and 1 Alarm Switch 1 Alarm Switch Catalog Number Catalog Number Catalog Number -- -- S01ED62A S02ED62As S03ED62A S15ED64As S04ED64As -- -- S01ED62AB S02ED62ABs S03ED62AB S15ED64ABs S04ED64ABs -- -- S01ED62B S02ED62Bs S03ED62Bs S15ED64Bs S04ED64Bs S16ED62As S07ED62A S09ED62As S11ED62As S13ED62As -- S07ED62ABs S09ED62ABs S11ED62ABs S13ED62ABs -- S07ED62Bs S09ED62Bs S11ED62Bs S13ED62Bs 1 Shunt Trip and 2 Auxiliary Switches Catalog Number -- -- S01ED62AA S02ED62AAs S03ED62AAs -- -- -- S07ED62AAs S09ED62AAs S11ED62AAs S13ED62AAs Undervoltage Trip Combinations Control Voltage AC DC 120 208 240 277 480 600 024 048 125 250 1 Undervoltage Trip Catalog Number U01ED60 U02ED60s U03ED60 U16ED60s U06ED60s U08ED60s U13ED60 U14ED60s U10ED60s U12ED60s 1 Undervoltage Trip 1 Undervoltage and 1 Auxiliary 1 Undervoltage Trip and Switch and Trip and 1 Auxiliary Switch 1 Alarm Switch 1 Alarm Switch Catalog Number Catalog Number Catalog Number U01ED62A U02ED62As U03ED62As U16ED64As U06ED64As -- U01ED62ABs U02ED62ABs U03ED62ABs U16ED64ABs U06ED64ABs -- U01ED62Bs U02ED62Bs U03ED62Bs U16ED64Bs U06ED64Bs -- U13ED62As U14ED62As U10ED62As U12ED62As U13ED62ABs U14ED62ABs U10ED62ABs -- U13ED62Bs U14ED62Bs U10ED62Bs -- 1 Undervoltage Trip and 2 Auxiliary Switches Catalog Number U01ED62AAs U02ED62AAs U03ED62AAs -- -- -- U13ED62AAs U14ED62AAs U10ED62AAs U12ED62AAs Auxiliary Switch Combinations Maximum Voltage AC DC 240 250 480 1 Auxiliary Switch Catalog Number A01ED62 A01ED64 1 Alarm Switch and 1 Auxiliary Switch Catalog Number A01ED62B A01ED64B 2 Auxiliary Switches Catalog Number A02ED62 -- Maximum Voltage AC DC 24 1 Auxiliary Switch Catalog Number A01EDLV Gold Plated Contacts--for PLCuse 1 Alarm Switch and 2 Auxiliary Switches Catalog Number A02ED62B -- MOLDED CASE 7 CIRCUIT BREAKERS GF01ED60 s Built to order. Allow 68 weeks for delivery. Alarm Switch Only Maximum Voltage AC DC 240 250 480 1 Alarm Switch Catalog Number B00ED62 B00ED64 Ground Fault Sensing Relay Kit -- Equipment Protection Only For Use With Breaker Frame CED6, ED2, ED4 ED6, EFC, EFF, HED4, HHED6 Number of Poles Description Basic Kit 1, 2, 3 Basic Kit with Normally Open Bell Alarm Basic Kit with Normally Closed Bell Alarm Catalog Number 30mA GF01ED60 GF01ED60B0 GF01ED60BC 5mA GF01ED65 GF01ED65B0s GF01ED65BCs 7-116 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Revised on 02/28/22 FD 250A Frame Sentron Series Selection Type FXD6-Aa Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) Continuous Current Rating @ 40°C 70 80 90 100 110 125 150 175 200 225 250 2-Pole Catalog Number FXD62B070n FXD62B080n FXD62B090n FXD62B100 FXD62B110n FXD62B125 FXD62B150 FXD62B175 FXD62B200 FXD62B225 FXD62B250 3-Pole Catalog Number FXD63B070 FXD63B080 FXD63B090 FXD63B100 FXD63B110 FXD63B125 FXD63B150 FXD63B175 FXD63B200 FXD63B225 FXD63B250 Type FD6-A Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog Number 2-Pole 600V AC, 250V DCb 70 FD62B070n 80 FD62B080n 90 FD62B090n 100 FD62B100n 110 FD62B110n 125 FD62B125n 150 FD62B150 175 FD62B175n 200 FD62B200 225 FD62B225n 250 FD62B250n 3-Pole 600V AC, 500V DCc 70 FD63B070n 80 FD63B080n 90 FD63B090n 100 FD63B100 110 FD63B110n 125 FD63B125 150 FD63B150 175 FD63B175 200 FD63B200 225 FD63B225 250 FD63B250 Frame Only Catalog Number FD62F250 FD63F250 Blue Label Trip Unit Only Catalog Number FD62T070n FD62T080n FD62T090n FD62T100n FD62T110n FD62T125n FD62T150 FD62T175n FD62T200 FD62T225n FD62T250n FD63T070n FD63T080n FD63T090n FD63T100 FD63T110n FD63T125 FD63T150 FD63T175 FD63T200 FD63T225 FD63T250 Interrupting Ratings Breaker Type FXD6-A, FD6-A HFXD6 , HFD6 HHFD6 , HHFXD6 CFD6 RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC (50/60Hz) Volts DC 240 480 600 250 500 c 65 35 22 30 (2-P) 18 (3-P) 100 65 25 30 (2-P) 25 (3-P) 200 100 25 -- -- 200 200 100 30 (2-P) 50 (3-P) IEC 947-2g Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu lcs 65 33 35 18 100 50 65 33 ------ -- ------ -- 500 lcu lcs -- -- -- -- -- -- -- -- Instantaneous Adjustment Trip Range Nominal Instantaneous Values +20% Breaker Ampere Tolerance Rating Low 2 3 4 170-90 100-110 125-150 175-200 225-250 600 700 800 900 1100 640 770 900 1060 1300 690 840 1000 1210 1500 730 920 1100 1370 1700 5 770 990 1200 1520 1900 6 810 1060 1300 1780 2100 7 850 1140 1400 1930 2300 +20% Tolerance High 900 1200 1500 2000 2500 Note: FD frame qualified to UL489 supplement SB "NAVAL". See page 7-159 for additional information. Ordering Information Complete Breaker Unassembled with Lugs Prices of FD6, HFD6, and HHFD6 breakers includes frame, trip and both line and load lugs (TA1FD350A). When ordered by these catalog numbers, the customer will receive the frame, trip, and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of FXD6, HFXD6, HHFXD6, and CFD6 includes frame with non-interchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA1FD350A) installed, add suffix "L" to catalog number (add 2 times list price of lugs for each pole). 50°C Applications see page 7-159. 400 Hz Applications see page 7-159. Lugs For 75°C Wiree Catalog Number Wire Range TA1FD350A TC1FD350 #6--350 kcmil Cu #4--350 kcmil Al #6--350 kcmil Cu Compression Lug CCF250 350 kcmil Cu/Al Enclosures Type 1 3R 4-4X 7-9 12 Neutral d Catalog Number F6N1S(F) F6N3R FD6SS4 EC2 F6N12 N250 Modifications page 7-159 Enclosures Section 6 Accessories pages 7-119 and 7-163 to 7-168 n Built to order. Allow 23 weeks for delivery. aType FXD6-A circuit breakers are UL Listed for reverse fed applications. b2-pole units are 3-pole width. c When wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. d Order neutral as separate item. e See Note: A, page 7-156. f HACR rated. g Only applicable to non-interchangeable trip unit types: FXD6A, HFXD6A. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-117 MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers FD 250A Frame Sentron Series Type HFD6, Type HFXD6bc Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog Number Frame Only Catalog Number 2-Pole 600V AC, 250V DC (3-Pole Width) 70 HFD62B070n 80 HFD62B080n 90 HFD62B090n 100 HFD62B100n 110 HFD62B110n 125 HFD62B125n 150 HFD62B150n 175 HFD62B175n 200 HFD62B200n 225 HFD62B225n 250 HFD62B250n HFD62F250 3-Pole 600V AC, 500V DC 70 HFD63B070n 80 HFD63B080n 90 HFD63B090n 100 HFD63B100 110 HFD63B110n 125 HFD63B125 150 HFD63B150 175 HFD63B175 200 HFD63B200 225 HFD63B225 250 HFD63B250 HFD63F250 Type HHFD, HHFXD6bc 3-Pole 600V AC, Extra High Interrupting 70 HHFD63B070n 80 HHFD63B080n 90 HHFD63B090n 100 HHFD63B100 110 HHFD63B110n 125 HHFD63B125 150 HHFD63B150 175 HHFD63B175 200 HHFD63B200 225 HHFD63B225 250 HHFD63B250 HHFD63F250 Black Label Trip Unit Only Catalog Number FD62T070n FD62T080n FD62T090n FD62T100n FD62T110n FD62T125n FD62T150n FD62T175n FD62T200n FD62T225n FD62T250n FD63T070n FD63T080n FD63T090n FD63T100 FD63T110n FD63T125 FD63T150 FD63T175 FD63T200 FD63T225 FD63T250 FD63T070n FD63T080n FD63T090n FD63T100 FD63T110n FD63T125 FD63T150 FD63T175 FD63T200 FD63T225 FD63T250 Type CFD6-Ac Fuseless Current Limiting Red Label Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Continuous Current Rating @ 40°C 3-Pole 600V AC/500V DC Catalog Number 070 CFD63B070n 080 CFD63B080n 090 CFD63B090n 100 CFD63B100n 110 CFD63B110n 125 CFD63B125n 150 CFD63B150 175 CFD63B175 200 CFD63B200 225 CFD63B225 250 CFD63B250 n Built to order. Allow 23 weeks for delivery. a W hen wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems. b For non-interchangeable trip 3-pole HFD6 type circuit breaker, change prefix identifier from HFD6 to HFXD6. Price equals frame and trip prices combined, e.g. price of HFXD63B250 equals price of HFD63F250 plus price of FD63T250. Order lugs separately. c Type HFXD6, HHFXD6, CFD6 are UL Listed for reverse feed applications. Selection/Dimensions L W D Figure 1 Figure 2 Dimensions (in inches) Breaker Type WL D Figure 1 FXD6-A, FD6-A, HFD6, HFXD6, 4.50 09.50 4 HHFD6, FD6-ETI Figure 2 CFD6, CFD6-ETI 4.50 14.25 4 D1 (to handle) 5.25 5.25 Shipping Weights Number of Poles Number per Shipping Carton Weight (lbs.) FD6-A, HFD6, HHFD6, FXD6-A Assembled Circuit Breaker (less connectors) 2 1 08.6 3 1 10 FD6-A, HFD6, HHFD6 Frame Only 2 1 07.5 3 1 08.7 FD6 Trip Unit Only 2 1 01.1 3 1 01.3 CFD6 Assembled Circuit Breaker (less terminals) 3 1 16 d F XD6, ETI, CFD6, ETI -- See page 7-143 for ordering information. HACR rated. MOLDED CASE 7 CIRCUIT BREAKERS 7-118 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Revised on 08/31/20 Internal Accessories Accessories: for FD, FFC & FFF 250A Frames Shunt Trip Combinations Control Voltage AC DC 024 120 240 277 480 600 012 024 048 125 250 1 Shunt Trip Catalog Number S17FD60 S01FD60 S03FD60 S15FD60s S04FD60 S06FD60s S16FD60s S07FD60 S09FD60s S11FD60 S13FD60s Selection S01FD60 Undervoltage Trip Combinations Control Voltage 1 Undervoltage Trip 1 Undervoltage Trip and 1 Auxiliary Switch AC 120 208 240 277 480 DC 024 048 125 Catalog Number U01FD60 U02FD60s U03FD60 U16FD60s U06FD60s U13FD60 U14FD60s U10FD60s Catalog Number W01FD64 W02FD64s W03FD64s W16FD64s W06FD64s W13FD64 W14FD64s W10FD64s Auxiliary Switch Combinations Voltage AC 240 480 DC 24 1 Auxiliary Switch Catalog Number A01FD62 A01FD64 A01FDLV 2 Auxiliary Switches Catalog Number A02FD62 A02FD64 Gold Plated Contacts for PLC use Alarm Switch Combinations Maximum Voltage AC DC 480 250 1 Alarm Switch Catalog Number B00FD64 1 Alarm Switch and 1 Auxiliary Switch Catalog Number C01FD64 MOLDED CASE 7 CIRCUIT BREAKERS s Built to order. Allow 68 weeks for delivery. aAuxiliary switch application is for 480V AC maximum. Note: Old F-frame accessories cannot be used in new Sentron line. Likewise, new FD-frame accessories cannot be used on old F-frame circuit breakers. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-119 Molded Case Circuit Breakers Revised on 02/28/22 JD 400A Frame Sentron Series Type JXD2-A 240V AC, 2-Pole 250V DC Only Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Continuous Current Rating @ 40°C 2-Pole (3-Pole Width) Catalog Number 3-Pole Catalog Number 200 JXD22B200n JXD23B200 225 JXD22B225n JXD23B225 250 JXD22B250n JXD23B250 300 JXD22B300 JXD23B300 350 JXD22B350n JXD23B350 400 JXD22B400 JXD23B400 Type JXD6-Aa 600V AC, 2-Pole 250V DC, 3-Pole 500V DC b Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) 200 JXD62B200n JXD63B200 225 JXD62B225n JXD63B225 250 JXD62B250n JXD63B250 300 JXD62B300 JXD63B300 350 JXD62B350n JXD63B350 400 JXD62B400 JXD63B400 Type JD6-A Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog Number Frame Only Catalog Number 2-Pole 600V AC, 250V DC (3-Pole Width) 200 JD62B200n 225 JD62B225n 250 JD62B250n 300 JD62B300n 350 JD62B350n 400 JD62B400 JD62F400 3-Pole 600V AC, 500V DCb 200 JD63B200 225 JD63B225 250 JD63B250 300 JD63B300 350 JD63B350 400 JD63B400 JD63F400 Interrupting Ratings Blue Label Trip Unit Only Catalog Number JD62T200n JD62T225n JD62T250n JD62T300n JD62T350n JD62T400 JD63T200 JD63T225 JD63T250 JD63T300 JD63T350 JD63T400 Breaker Type JXD2-A JXD6-A, JD6-A HJD6-A, HJXD6-A HHJD6, HHJXD6 CJD6-A RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC Volts DC (50/60Hz) 240 480 600 250 500 b 065 -- -- 30 (2-P) -- 065 035 025 30 (2-P) 25 (3-P) 100 065 035 30 (2-P) 35 (3-P) 200 100 050 -- -- 200 150 100 30 (2-P) 50 (3-P) IEC 947-2e Volts AC (50/60Hz) 220/240 380/415 lcu lcs lcu lcs -- ---- -- 065 033 040 20 100 050 065 33 -- ---- -- -- ---- -- 500 lcu lcs -- -- -- -- -- -- -- -- -- -- Instantaneous Adjustment Trip Range Nominal Instantaneous Values +20% +20% Breaker Ampere Tolerance Tolerance Rating Low 2 3 4 5 6 7 High 200-300 350-400 1250 2000 1430 2290 1610 2570 1790 1960 2860 3140 2140 2320 3430 3710 2500 4000 n Built to order. Allow 23 weeks for delivery. aType JXD2 and JXD6 circuit breakers are UL Listed for reverse feed applications. bW hen wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. cSee Note: A, page 7-156. dHACR rated. e Only applicable to non-interchangeable trip unit types: JXD6-A, HJXD6-A. Note: JD frame qualified to UL489 supplement B "NAVAL." See page 7-159 for additional information. 7-120 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Selection Ordering Information Complete Breaker Unassembled with Lugs Prices of JD6, HJD6, and HHJD6 breakers include frame, trip and both line and load lugs (TA2J6500). When ordered by these catalog numbers, the customer will receive the frame, trip, and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of JXD6, HJXD6, HHJXD6, and CJD6 include frame with non-interchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA2J6500) installed, add suffix "L" to catalog number (add 2 times list price of lugs for each pole). 100% Rated (3-pole only) Types JXD6 and HJXD6 breakers are available with 100% ratings. To order add suffix "H" to catalog number, and 10% to list price.n 100% rated JD breakers require the use of 90°C Cu cable sized at 75°C ampacity and lugs TC1J6600 or TC2J6500. 50°C Applications see page 7-159. 400Hz Applications see page 7-159. Lugs For 75°C Wirec Catalog Number Cables per Lug TA2J6500 1, 2 2 TA1L6750 1 1 TC1J6600 1 TC2J6500 1, 2 Compression Lug CCL600 1 Wire Range #3/0-500 kcmil Cu #4/0-500 kcmil Al 500-750 kcmil Al 500-600 kcmil Cu #3/0-600 kcmil Cu #3/0-500 kcmil Cu 500 kcmil Cu/Al Modifications page 7-159 Enclosures Section 6 Accessories pages 7-123 and 7-163 to 7-168 Product Category MCCB MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers JD 400A Frame Sentron Series Type HJD6-A, HJXD6-Abdf Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog Number Frame Only Catalog Number 2-Pole 600V AC, 250V DC (3-Pole Width) 200 HJD62B200n 225 HJD62B225n 250 HJD62B250n HJD62F400n 300 HJD62B300n 350 HJD62B350n 400 HJD62B400n 3-Pole 600V AC, 500V DCabe 200 HJD63B200 225 HJD63B225 250 HJD63B250 300 HJD63B300 350 HJD63B350 400 HJD63B400 HJD63F400 Black Label Trip Unit Only Catalog Number JD62T200n JD62T225n JD62T250n JD62T300n JD62T350n JD62T400 JD63T200 JD63T225 JD63T250 JD63T300 JD63T350 JD63T400 Type HHJD6, HHJXD6bdf 2-Pole 600V AC (3-Pole Width) 200 HHJD62B200n 225 HHJD62B225n 250 HHJD62B250n 300 HHJD62B300n 350 HHJD62B350n 400 HHJD62B400n 3-Pole 600VAC 200 HHJD63B200 225 HHJD63B225 250 HHJD63B250 300 HHJD63B300 350 HHJD63B350 400 HHJD63B400 HHJD62F400n HHJD63F400 Type CJD6-A ef Fuseless Current Limiting Red Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) Continuous Current Rating @ 40°C 2-Pole 600V AC/250V DC Catalog Number 3-Pole 600V AC/500V DC Catalog Number 200 CJD63B200n 225 CJD63B225n 250 300 For 2-pole application use outside poles of 3-pole circuit breaker CJD63B250n CJD63B300n 350 CJD63B350n 400 CJD63B400 Black Label JD62T200n JD62T225n JD62T250n JD62T300n JD62T350n JD62T400 JD63T200 JD63T225 JD63T250 JD63T300 JD63T350 JD63T400 Selection/Dimensions D1 W D Figure 1 D Figure 2 Dimensions (in inches) Breaker Type W L D Figure 1 JXD2-A, JXD6-A, JD6-A HJD6-A, HJXD6-A, HHJD6, 7.5 11 4 HJD6, HJXD6, HHJXD6, JXD6-ETI,c SJD6, SHJD6 Figure 2 CJD6, CJD6-ETI,c SCJD6 7.5 17.86 4 To Handle D1 5.44 5.44 Enclosures (Except SCJD6) Type 1 3R 12 4X 7, 9 (200-250A) 7, 9 (300-400A) Neutral Catalog Number J6N1 J6N3R J6N12 LD6SS4 EC4 EE W60992 Shipping Weights Number of Poles Number per Shipping Carton Weight (lbs.) JXD2, JXD6, JD6, HJD6, HHJD6 Assembled Breaker (less terminals) 2 1 17.5 3 1 19.5 JD6, HJD6, HHJD6 Frame Only 2 1 14 3 1 15.5 JD6 Trip Unit Only 2 1 03.5 3 1 04 CJD6 Complete Assembled Breaker (less terminals) 3 1 31.5 MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. n Built to order. Allow 23 weeks for delivery. 2-pole units available in 3-pole construction. a When wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. b For non-interchangeable 3-pole HJD6 or HHJD6 type circuit breaker change the prefix identifier to HJXD6 or HHJXD6. Price equals price of frame plus price of trip, e.g. price of HJXD63B400 equals price of HJD63F400 plus price of JD63T400. Order lugs separately. c JXD6-ETI, CJD6-ETI see page 7-143 for ordering information. d Type HJXD6, HHJXD6 Circuit Breakers are UL listed for reverse fed applications. e CE applies to non-interchangeable type HJXD6-A only. f HACR rated. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-121 Molded Case Circuit Breakers Revised on 10/31/18 SJD 400A Frame Digital Solid State Sentron Sensitrip IV Series Selection Type SJD6-B Blue Label Max Current Rating 200 300 400 200 300 400 200 300 400 200 300 400 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SJD6A200LI SJD6A300LI SJD6A400LI SJD6A200LIG SJD6A300LIG SJD6A400LIG SJD6A200LSI SJD6A300LSI SJD6A400LSI SJD6A200LSIG SJD6A300LSIG SJD6A400LSIG Catalog Number (Basic trip unit) SJD6B200LI SJD6B300LI SJD6B400LI SJD6B200LIG SJD6B300LIG SJD6B400LIG SJD6B200LSI SJD6B300LSI SJD6B400LSI SJD6B200LSIG SJD6B300LSIG SJD6B400LSIG Type SHJD6-B Black Label Current Limiting Type SCJD6-B Red Label 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SHJD6A200LI SHJD6A300LI SHJD6A400LI SHJD6A200LIG SHJD6A300LIG SHJD6A400LIG SHJD6A200LSI SHJD6A300LSI SHJD6A400LSI SHJD6A200LSIG SHJD6A300LSIG SHJD6A400LSIG Catalog Number (Basic trip unit) SHJD6B200LI SHJD6B300LI SHJD6B400LI SHJD6B200LIG SHJD6B300LIG SHJD6B400LIG SHJD6B200LSI SHJD6B300LSI SHJD6B400LSI SHJD6B200LSIG SHJD6B300LSIG SHJD6B400LSIG 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SCJD6A200LI SCJD6A300LI SCJD6A400LI SCJD6A200LIG SCJD6A300LIG SCJD6A400LIG SCJD6A200LSI SCJD6A300LSI SCJD6A400LSI SCJD6A200LSIG SCJD6A300LSIG SCJD6A400LSIG Catalog Number (Basic trip unit) SCJD6B200LI SCJD6B300LI SCJD6B400LI SCJD6B200LIG SCJD6B300LIG SCJD6B400LIG SCJD6B200LSI SCJD6B300LSI SCJD6B400LSI SCJD6B200LSIG SCJD6B300LSIG SCJD6B400LSIG SJD 400A Frame 100% Ratedb Type SJD6-B Type SHJD6-B Blue Label Black Label Max Current Rating 200 300 400 200 300 400 200 300 400 200 300 400 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SJD6A200LIH SJD6A300LIH SJD6A400LIH SJD6A200LIGH SJD6A300LIGH SJD6A400LIGH SJD6A200LSIH SJD6A300LSIH SJD6A400LSIH SJD6A200LSIGH SJD6A300LSIGH SJD6A400LSIGH Catalog Number (Basic trip unit) SJD6B200LIH SJD6B300LIH SJD6B400LIH SJD6B200LIGH SJD6B300LIGH SJD6B400LIGH SJD6B200LSIH SJD6B300LSIH SJD6B400LSIH SJD6B200LSIGH SJD6B300LSIGH SJD6B400LSIGH 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SHJD6A200LIH SHJD6A300LIH SHJD6A400LIH SHJD6A200LIGH SHJD6A300LIGH SHJD6A400LIGH SHJD6A200LSIH SHJD6A300LSIH SHJD6A400LSIH SHJD6A200LSIGH SHJD6A300LSIGH SHJD6A400LSIGH Catalog Number (Basic trip unit) SHJD6B200LIH SHJD6B300LIH SHJD6B400LIH SHJD6B200LIGH SHJD6B300LIGH SHJD6B400LIGH SHJD6B200LSIH SHJD6B300LSIH SHJD6B400LSIH SHJD6B200LSIGH SHJD6B300LSIGH SHJD6B400LSIGH Trip Unit Adjustable Functions Suffix Letter Code LI LIG LSI LSIG Trip Type LI LIG LSI LSIG Cont Current Setting u u u u Long Time Delay u u u u Instantaneous Pick Up u u u u Short Time Pick Up u u Short Time Fixed Delay u u Short Time l2t Delay u u Ground Ground Fault Fault Pick Up Delay u u u u Interrupting Ratings Breaker Type SJD6-B SHJD6-B SCJD6-B RMS Symmetrical kA UL 489 (File E10848) 240V AC 480V AC 65 35 100 65 200 150 600V AC 25 35 100 Neutral Transformers Ampere Rating 200 300 400 Catalog Number N02SJD N03SJD N04SJD Ordering Information Pricing information for all Digital Sentron Series SJD Frames is for complete breaker only - price required lugs as separate items lugs are suitable for 75°C Wire. SJD6-B, SHJD6-B and SCJD6-B are acceptable for reverse connection application. Shipping Weights Breaker Type SJD6-B SHJD6-B Number per Carton 1 1 SCJD6-B 1 Shipping Weight (lbs) 20 20 33 Lugs for 75° C Wirea Catalog Number No. of cables per connector 2 TA2J6500 2 1 TA1L6750 1 TC1J6600 1 TC2J6500 2 TA2J630 2 Compression Lug CCL600 1 (pc.) Wire Range #3/0-500 kcmil Cu #4/0-500 kcmil Al 500-750 kcmil Al 500-600 kcmil Cu #3/0-600 kcmil Cu #3/0-500 kcmil Cu #4-#3/0 Cu/Al #1/0-500 kcmil Cu/Al MOLDED CASE 7 CIRCUIT BREAKERS Note: "G" suffix in catalog number denotes circuit breaker for 3-phase, 3-wire systems. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. All breakers built to order. Allow 23 weeks for delivery. aFor additional information, see Note: A, page 7-156. b Refer to the NEC for proper application of 100% rated devices. c Advanced trip unit equipped with DAS / Maintenance Mode. Requires customer-supplied 24V external power supply, maintenance switch and light. Enclosures Section 6 Accessories pages 7-123 and 7-163 to 7-168 7-122 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Revised on 08/31/20 Internal Accessories Accessories for: JD 400A Frame LD 600A Frame LMD 800A Frame SJD 400A Frame SLD 600A Frame Shunt Trip Combinations Control Voltage AC DC 024 048 120 240 277 480 012 024 048 125 250 1 Shunt Trip Catalog Number S17JLD6 S18JLD6s S01JLD6 S03JLD6 S15JLD6s S04JLD6 S16JLD6s S07JLD6 S09JLD6s S11JLD6 S13JLD6s 1 Shunt Trip and 1 Auxiliary Switch Catalog Number -- -- S01JLD62A S03JLD62A S15JLD64As -- S16JLD62As S07JLD62A S09JLD62A S11JLD62As S13JLD62As Selection S01JLD6 Undervoltage Trip Combinations Control Voltage 1 Undervoltage Trip 1 Undervoltage Trip and 1 Undervoltage Trip and 1 Auxiliary Switch 2 Auxiliary Switches AC 120 208 240 480 DC 024 048 125 Catalog Number U01JLD6 U02JLD6s U03JLD6 U06JLD6 U13JLD6 U14JLD6s U10JLD6s Catalog Number U01JLD62A U02JLD62As U03JLD62As U06JLD64As U13JLD62A U14JLD62As U10JLD62As Catalog Number U01JLD62AA U02JLD62AAs U03JLD62AAs U06JLD64AAs U13JLD62AA U14JLD62AAs U10JLD62AAs Auxiliary Switch Combinations Maximum Voltage AC DC 480 250 -- 24 1 Form C Catalog Number A01JLD64 A01JLDLV 2 Form C Catalog Number A02JLD64 A02JLDLV Alarm Switch Combinations Maximum Voltage AC DC 480 250 1 Alarm Switch Catalog Number B01JLD64 1 Alarm Switch and 1 Auxiliary Switch Catalog Number A01JLD64B 1 Alarm Switch and 2 Auxiliary Switches CatalogNumber A02JLD64B ETU Testing Unit Breaker Type Description Catalog Number SJD, SLD, SMD, SND, SPD Power Stick Spare cable for Power Stick EPSP18V COMPCA The EPSP18V Power Stick is a hand-held, battery-operated power supply that can be used for trip testing the Sensitrip IV electronic trip units. Requires two 9V batteries. MOLDED CASE 7 CIRCUIT BREAKERS Note: Accessory modules can only be added to right side pole of solid state SJD and SLD frame circuit breakers. No accessories can be added if mechanical interlock is used. All accessories on this page are useable on superseded JD2, JJ6, JL6, HJ6, SJL, LJ6, LL6, HL6 and SLL circuit breakers. s Built to order. Allow 68 weeks for delivery. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-123 MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers LD 600A Frame Sentron Series Type LXD6-Aad Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Continuous Current Rating @ 40° C 450 500 600 2-Pole (3-Pole Width) 600V AC 250V DC Catalog Number LXD62B450n LXD62B500n LXD62B600 3-Pole 600V AC 500V DC Catalog Number LXD63B450 LXD63B500 LXD63B600 Type LD6-Ad Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog Number Frame Only Catalog Number 2-Pole 600V AC, 250V DC (3-Pole Width) 250 LD62B250n 300 LD62B300n 350 LD62B350n 400 LD62B400 450 LD62B450n 500 LD62B500n 600 LD62B600 3-Pole 600V AC, 500V DC b LD62F600 250 LD63B250 300 LD63B300 350 LD63B350 400 LD63B400 450 LD63B450 500 LD63B500 600 LD63B600 LD63F600 Blue Label Trip Unit Only Catalog Number JD62T250n JD62T300n JD62T350n JD62T400 LD62T450n LD62T500n LD62T600 JD63T250 JD63T300 JD63T350 JD63T400 LD63T450 LD63T500 LD63T600 Interrupting Ratings Breaker Type LD6-A, LXD6-A HLD6-A, HLXD6-A HHLD6, HHLXD6 CLD6-A RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC (50/60Hz) Volts DC 240 480 600 250 500 c 065 035 025 30 (2-P) 25 (3-P) 100 065 035 30 (2-P) 35 (3-P) 200 100 050 -- -- 200 150 100 -- 50 (3-P) IEC 947-2e Volts AC (50/60Hz) 220/240 380/415 500 (lcu) (lcs) (lcu) (lcs) (lcu) (lcs) 065 033 040 20 -- -- 100 050 065 33 -- -- -- ---- ---- -- -- ---- ---- -- Instantaneous Adjustment Trip Range Breaker Ampere Rating 250-300 350-450 500-600 Nominal Instantaneous Values +20% Tolerance Low 2 3 4 1250 2000 3000 1430 2290 3430 1610 2570 3800 1790 2860 4290 5 1960 3140 4710 6 2140 3430 5140 7 2320 3710 5570 +20% Tolerance High 2500 4000 6000 n Built to order. Allow 23 weeks for delivery. aType LXD6A circuit breakers are UL Listed for reverse fed applications. b When wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. c See Note: A, page 7-156. d HACRrated. e Only applicable to non-interchangeable trip unit types: LXD6, HLXD6. Note: LD frame qualified to UL489 supplement SB "NAVAL". See page 7-159 for additional information. Modifications page 7-159 Enclosures Section 6 Accessories pages 7-127 and 7-163 to 7-168 7-124 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Revised on 02/28/22 Selection Ordering Information Complete Breaker Unassembled with Lugs Prices of LD6, HLD6, and HHLD6 breakers include frame, trip, and both line and load lugs (TA2J6500). When ordered by these catalog numbers, the customer will receive the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of LXD6, HLXD6, HHLXD6, and CLD6 include frame with noninterchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA2J6500) installed, add suffix "L" to catalog number (add 2 times list price of lugs for each pole). 100% Rated (3-pole only) Types LXD6 and HLXD6 breakers are available with 100% ratings. To order add suffix "H" to catalog number, and 10% to list price. 100% rated LD breakers require the use of 90°C Cu cable sized at 75°C ampacity and lugs TC1J6600 or TC2J6500. 50°C Applications see page 7-159. 400Hz Applications see page 7-159. Shipping Weights Number of Poles Number per Shipping Carton Weight (lbs.) LXD6, LD6, HLD6, HHLD6 Assembled Breaker (less terminals) 2 1 17.5 3 1 19.5 LD6, HLD6, HHLD6 Frame Only 2 1 14 3 1 15.5 LD6, HHLD6 Trip Unit Only 2 1 03.5 3 1 04 CLD6 Complete Assembled Breaker (less terminals) 3 1 31.5 Lugs For 75°C Wirec Catalog Number Cables per Lug TA2J6500 1, 2 2 TC2J6500 2 TA1L6750 1 1 TC1J6600 1 Compression Lug CCL600 1 Wire Range #3/0 500 kcmil Cu #4/0 500 kcmil Al #3/0-500 kcmil Cu 500-750 kcmil Al 500-600 kcmil Cu #3/0-600 kcmil Cu 500 kcmil Cu/Al Product Category MCCB Molded Case Circuit Breakers LD 600A Frame Sentron Series Type HLD6-A, HLXD6-Abcf Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog Number Frame Only Catalog Number 2-Pole 600V AC, 250V DC (3-Pole Width) 250 HLD62B250n 300 HLD62B300n 350 HLD62B350n 400 HLD62B400n 450 HLD62B450n 500 HLD62B500n 600 HLD62B600n HLD62F600n 3-Pole 600V AC, 500V DCae 250 HLD63B250 300 HLD63B300 350 HLD63B350 400 HLD63B400 450 HLD63B450 500 HLD63B500 600 HLD63B600 HLD63F600 Type HHLD6, HHLXD6bcf 2-Pole 600V AC (3-Pole Width) 250 HHLD62B250n 300 HHLD62B300n 350 HHLD62B350n 400 HHLD62B400n 450 HHLD62B450n 500 HHLD62B500n 600 HHLD62B600n 3-Pole 600V AC 250 HHLD63B250 300 HHLD63B300 350 HHLD63B350 400 HHLD63B400 450 HHLD63B450n 500 HHLD63B500n 600 HHLD63B600n HHLD62F600n HHLD63F600 Black Label Trip Unit Only Catalog Number JD62T250n JD62T300n JD62T350n JD62T400 LD62T450n LD62T500n LD62T600 JD63T250 JD63T300 JD63T350 JD63T400 LD63T450 LD63T500 LD63T600 Black Label JD62T250n JD62T300n JD62T350n JD62T400 HHLD62T450n HHLD62T500n HHLD62T600n JD63T250 JD63T300 JD63T350 JD63T400 HHLD63T450n HHLD63T500n HHLD63T600n Type CLD6-Acf Fuseless Current Limiting Red Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) Continuous Current Rating @ 40°C 2-Pole 600V AC/250V DC Catalog Number 3-Pole 600V AC/500V DC Catalog Number 450 For 2-pole application CLD63B450n 500 use outside poles of CLD63B500 600 3-pole circuit breaker CLD63B600 Selection/Dimensions D1 L L D Figure 1 D Figure 2 Dimensions (in inches) Breaker Type Figure 1 LXD6-A, LD6-A HLD6-A HHLD6, HHLXD6, LXD6ETI,d SLD6, SHLD6 Figure 2 CLD6, CLD6-ETI,d SCLD6 To Handle W L D D1 7.5 11 4 5.44 7.5 17.86 4 5.44 Enclosures: (except SCLD6) Type 1 3R 12 4X 7,9 Neutral Catalog Number LD6N1 LD6N3R LD6N12 LD6SS4 ED6 W60993 MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. n Built to order. Allow 23 weeks for delivery. a When wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. b For complete assembled 3-pole HLD6 or HHLD6 type circuit breaker change the prefix identifier HLD6 or HHLD6 to HLXD6 or HHLXD6. Price is sum of frame and trip units prices, e.g. price of HLXD63B400 is the price of HLD63F600 plus the price of LD63T600. Order the terminal connectors separately. cType HLXD6, HHLXD6, & CLD6 Circuit Breakers are UL Listed for reverse feed applications. d LXD6-ETI, CLD6-ETI see page 7-143 for ordering information. e CE Applies to non-interchangeable type HLXD only. f HACR rated. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-125 Molded Case Circuit Breakers SLD 600A Frame Digital Solid State Sentron Sensitrip IV Series Type SLD6-B Blue Label Max Current Rating 300 400 500 600 300 400 500 600 300 400 500 600 300 400 500 600 3-Pole, 600V AC Catalog Number (Advanced trip unit)a SLD6A300LI SLD6A400LI SLD6A500LI SLD6A600LI SLD6A300LIG SLD6A400LIG SLD6A500LIG SLD6A600LIG SLD6A300LSI SLD6A400LSI SLD6A500LSI SLD6A600LSI SLD6A300LSIG SLD6A400LSIG SLD6A500LSIG SLD6A600LSIG Catalog Number (Basic trip unit) SLD6B300LI SLD6B400LI SLD6B500LI SLD6B600LI SLD6B300LIG SLD6B400LIG SLD6B500LIG SLD6B600LIG SLD6B300LSI SLD6B400LSI SLD6B500LSI SLD6B600LSI SLD6B300LSIG SLD6B400LSIG SLD6B500LSIG SLD6B600LSIG Type SHLD6-B Black Label 3-Pole, 600V AC Catalog Number (Advanced trip unit)a SHLD6A300LI SHLD6A400LI SHLD6A500LI SHLD6A600LI SHLD6A300LIG SHLD6A400LIG SHLD6A500LIG SHLD6A600LIG SHLD6A300LSI SHLD6A400LSI SHLD6A500LSI SHLD6A600LSI SHLD6A300LSIG SHLD6A400LSIG SHLD6A500LSIG SHLD6A600LSIG Catalog Number (Basic trip unit) SHLD6B300LI SHLD6B400LI SHLD6B500LI SHLD6B600LI SHLD6B300LIG SHLD6B400LIG SHLD6B500LIG SHLD6B600LIG SHLD6B300LSI SHLD6B400LSI SHLD6B500LSI SHLD6B600LSI SHLD6B300LSIG SHLD6B400LSIG SHLD6B500LSIG SHLD6B600LSIG Revised on 10/31/18 Selection Current Limiting Type SCLD6-B Red Label 3-Pole, 600V AC Catalog Number (Advanced trip unit)a SCLD6A300LI SCLD6A400LI SCLD6A500LI SCLD6A600LI SCLD6A300LIG SCLD6A400LIG SCLD6A500LIG SCLD6A600LIG SCLD6A300LSI SCLD6A400LSI SCLD6A500LSI SCLD6A600LSI SCLD6A300LSIG SCLD6A400LSIG SCLD6A500LSIG SCLD6A600LSIG Catalog Number (Basic trip unit) SCLD6B300LI SCLD6B400LI SCLD6B500LI SCLD6B600LI SCLD6B300LIG SCLD6B400LIG SCLD6B500LIG SCLD6B600LIG SCLD6B300LSI SCLD6B400LSI SCLD6B500LSI SCLD6B600LSI SCLD6B300LSIG SCLD6B400LSIG SCLD6B500LSIG SCLD6B600LSIG Trip Unit Adjustable Functions Suffix Letter Code LI LIG LSI LSIG Trip Type LI LIG LSI LSIG Cont Current Setting u u u u Long Time Delay u u u u Instantaneous Pick Up u u u u Short Time Pick Up u u Short Time Fixed Delay u u Short Time l2t Delay u u Ground Ground Fault Fault Pick Up Delay u u u u Interrupting Ratings Breaker Type SLD6-B SHLD6-B SCLD6-B RMS Symmetrical kA UL 489 (File E10848) 240V AC 480V AC 65 35 100 65 200 150 600V AC 25 35 100 Neutral Transformers Ampere Rating 300 400 500 600 Catalog Number N03SJD N04SJD N05SLD N06SLD Ordering Information Pricing information for all Digital Sentron Series SLD Frames is for complete breaker only price required lugs as separate items lugs are suitable for 75°C Wire. SLD6, SHLD6 and SCLD6 are acceptable for reverse connection application. Shipping Weights Breaker Type SLD6-B SHLD6-B Number per Carton 1 1 SCLD6-B 1 Shipping Weight (lbs) 20 20 33 MOLDED CASE 7 CIRCUIT BREAKERS Note: "G" suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. For ordering information and terminal connectors see page 7-124; for enclosures, see page 7-125. 100% Rated Not available in SLD6 Frame. All breakers built to order. Allow 2-3 weeks for delivery. 7-126 Siemens Industry, Inc. SPEEDFAXTM Product Catalog a Advanced trip unit equipped with DAS / Maintenance Mode. Requires customer-supplied 24V external power supply, maintenance switch and light. Product Category MCCB Molded Case Circuit Breakers Revised on 08/31/20 Internal Accessories Accessories for: JD 400A Frame LD 600A Frame LMD 800A Frame SJD 400A Frame SLD 600A Frame Shunt Trip Combinations Control Voltage AC DC 024 048 120 240 277 480 012 024 048 125 250 1 Shunt Trip Catalog Number S17JLD6 S18JLD6s S01JLD6 S03JLD6 S15JLD6s S04JLD6 S16JLD6s S07JLD6 S09JLD6s S11JLD6 S13JLD6s 1 Shunt Trip and 1 Auxiliary Switch Catalog Number -- -- S01JLD62A S03JLD62A S15JLD64As -- S16JLD62As S07JLD62A S09JLD62A S11JLD62As S13JLD62As Selection S01JLD6 Undervoltage Trip Combinations Control Voltage 1 Undervoltage Trip 1 Undervoltage Trip and 1 Undervoltage Trip and 1 Auxiliary Switch 2 Auxiliary Switches AC 120 208 240 480 DC 024 048 125 Catalog Number U01JLD6 U02JLD6s U03JLD6 U06JLD6 U13JLD6 U14JLD6s U10JLD6s Catalog Number U01JLD62A U02JLD62As U03JLD62As U06JLD64As U13JLD62A U14JLD62As U10JLD62As Catalog Number U01JLD62AA U02JLD62AAs U03JLD62AAs U06JLD64AAs U13JLD62AA U14JLD62AAs U10JLD62AAs Auxiliary Switch Combinations Maximum Voltage AC DC 480 250 -- 24 1 Form C Catalog Number A01JLD64 A01JLDLV 2 Form C Catalog Number A02JLD64 A02JLDLV Alarm Switch Combinations Maximum Voltage AC DC 480 250 1 Alarm Switch Catalog Number B01JLD64 1 Alarm Switch and 1 Auxiliary Switch Catalog Number A01JLD64B 1 Alarm Switch and 2 Auxiliary Switches CatalogNumber A02JLD64B ETU Testing Unit Breaker Type Description Catalog Number SJD, SLD, SMD, SND, SPD Power Stick Spare cable for Power Stick EPSP18V COMPCA The EPSP18V Power Stick is a hand-held, battery-operated power supply that can be used for trip testing the Sensitrip IV electronic trip units. Requires two 9V batteries. MOLDED CASE 7 CIRCUIT BREAKERS Note: Accessory modules can only be added to right side pole of solid state SJD and SLD frame circuit breakers. No accessories can be added if mechanical interlock is used. All accessories on this page are useable on superseded JD2, JJ6, JL6, HJ6, SJL, LJ6, LL6, HL6 and SLL circuit breakers. s Built to order. Allow 68 weeks for delivery. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-127 Molded Case Circuit Breakers LMD 800A Frame Sentron Series Selection Type LMXD6ad Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Continuous Current Rating @ 40°C 2-Pole (3-Pole Width) Catalog Number 3-Pole Catalog Number 500 -- LMXD63B500n 600 LMXD62B600n LMXD63B600 700 LMXD62B700n LMXD63B700 800 LMXD62B800 LMXD63B800 Type LMD6d Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog Number Frame Only Catalog Number 2-Pole 600V AC, 250V DC (3-Pole Width) 500 LMD62B500n 600 LMD62B600n 700 LMD62B700n 800 LMD62B800n 3-Pole 600V AC, 500V DCb LMD62F800n 500 LMD63B500n 600 LMD63B600n 700 LMD63B700n 800 LMD63B800 LMD63F800 Blue Label Trip Unit Only Catalog Number LMD62T500n LMD62T600n LMD62T700n LMD62T800n LMD63T500n LMD63T600n LMD63T700n LMD63T800 Instantaneous Adjustment Trip Range Ampere Rating 500-600 700-800 Nominal Instantaneous Values Low +/- 20% 2 3 Tolerance 3000 3430 3860 3200 3500 3700 4 4290 4200 5 4710 4700 6 5140 6400 7 5570 7300 High +/- 20% Tolerance 6000 8000 Ordering Information Complete Breaker Unassembled with Lugs Prices of LMD6 and HLMD6 breakers include frame, trip, and both line and load lugs (TA3K500). These catalog numbers include the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of LMXD6 and HLMXD6 include frame with non-interchangeable trip unit installed only. Order required lugs separately. For line and load lugs (TA3K500) installed, add suffix "L" to catalog number (add 2 times list price of lugs for each pole). 50°C Applications see page 7-159. 400Hz Applications see page 7-159. Shipping Weights Number of Poles Number per Shipping Carton Weight (lbs.) LMD6, HLMD6, LMXD6, HLMXD6 Complete Breaker (less terminals) 2 1 53 3 1 61.5 LMD6, HLMD6 Frame Only 2 1 42.25 3 1 46 LMD6, HLMD6 Trip Unit Only 2 1 4.5 3 1 6.5 Lugsc for 75°C Wire Catalog Number TA2K500 TA3K500 TA2N750 Cables per Lug 1, 2 1-3 1, 2 Wire Range #1-500 kcmil Cu / Al #1/0-500 kcmil Cu / Al 500-750 kcmil Cu / Al MOLDED CASE 7 CIRCUIT BREAKERS n Built to order. Allow 23 weeks for delivery. a LMXD6 circuit breakers are UL Listed for reverse connected applications. bWhen wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500VDC ungrounded UPS systems only. c See Note: A, page 7-156. d HACRrated. 7-128 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Modifications page 7-159 Enclosures Section 6 Accessories pages 7-130 and 7-163 to 7-168 Product Category MCCB Molded Case Circuit Breakers LMD 800A Frame Sentron Series Type HLMXD6ad Black Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) Continuous Current Rating @ 40°C 2-Pole 600V AC/250V DC Catalog Number 3-Pole 600V AC/500V DC Catalog Number 500 HLMXD63B500n 600 For 2-pole application HLMXD63B600n 700 use outside poles of 3-pole circuit breaker HLMXD63B700n 800 HLMXD63B800 Type HLMD6d Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled Catalog Number Frame Only Catalog Number 2-Pole 600V AC, 250V DC (3-Pole Width) 500 HLMD62B500n 600 HLMD62B600n 700 HLMD62B700n 800 HLMD62B800n 3-Pole 600V AC, 500V DCc HLMD62F800n 500 HLMD63B500 600 HLMD63B600 700 HLMD63B700 800 HLMD63B800 HLMD63F800 Interrupting Ratings Breaker Type LMD6, LMXD6 HLMD6, HLMXD6 UL 489A IR RMS Symmetrical Amperes (KA) Volts AC Volts DC 240 480 600 250 65 50 25 30 (2-P) 100 065 050 30 (2-P) 500 25 (3-P) 50 (3-P) Black Label Trip Unit Only Catalog Number LMD62T500n LMD62T600n LMD62T700n LMD62T800n LMD63T500 n LMD63T600 n LMD63T700 n LMD63T800 Selection/Dimensions Dimensions (in inches) Breaker Type W L D D1 LMD6, LMXD6, HLMD6, 7.5 16 4.5 5.93 HLMXD6 LMXD6-ETI b Enclosures Type 1 3R 12 Neutral Catalog Number LMD1 LMD3R LMD12n W63623 MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. n Built to order. Allow 23 weeks for delivery. aHLMXD6 circuit breakers are UL Listed for reverse connection applications. b LMXD6-ETI, see page 7-143 for catalog information. c When wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500VDC ungrounded UPS systems only. d HACR rated. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-129 Molded Case Circuit Breakers Revised on 08/31/20 Internal Accessories Accessories for: JD 400A Frame LD 600A Frame LMD 800A Frame SJD 400A Frame SLD 600A Frame Shunt Trip Combinations Control Voltage AC DC 024 048 120 240 277 480 012 024 048 125 250 1 Shunt Trip Catalog Number S17JLD6 S18JLD6s S01JLD6 S03JLD6 S15JLD6s S04JLD6 S16JLD6s S07JLD6 S09JLD6s S11JLD6 S13JLD6s 1 Shunt Trip and 1 Auxiliary Switch Catalog Number -- -- S01JLD62A S03JLD62A S15JLD64As -- S16JLD62As S07JLD62A S09JLD62A S11JLD62As S13JLD62As Selection S01JLD6 Undervoltage Trip Combinations Control Voltage 1 Undervoltage Trip 1 Undervoltage Trip and 1 Undervoltage Trip and 1 Auxiliary Switch 2 Auxiliary Switches AC 120 208 240 480 DC 024 048 125 Catalog Number U01JLD6 U02JLD6s U03JLD6 U06JLD6 U13JLD6 U14JLD6s U10JLD6s Catalog Number U01JLD62A U02JLD62As U03JLD62As U06JLD64As U13JLD62A U14JLD62As U10JLD62As Catalog Number U01JLD62AA U02JLD62AAs U03JLD62AAs U06JLD64AAs U13JLD62AA U14JLD62AAs U10JLD62AAs Auxiliary Switch Combinations Maximum Voltage AC DC 480 250 -- 24 1 Form C Catalog Number A01JLD64 A01JLDLV 2 Form C Catalog Number A02JLD64 A02JLDLV Alarm Switch Combinations Maximum Voltage AC DC 480 250 1 Alarm Switch Catalog Number B01JLD64 1 Alarm Switch and 1 Auxiliary Switch Catalog Number A01JLD64B 1 Alarm Switch and 2 Auxiliary Switches CatalogNumber A02JLD64B ETU Testing Unit Breaker Type Description Catalog Number SJD, SLD, SMD, SND, SPD Power Stick Spare cable for Power Stick EPSP18V COMPCA The EPSP18V Power Stick is a hand-held, battery-operated power supply that can be used for trip testing the Sensitrip IV electronic trip units. Requires two 9V batteries. MOLDED CASE 7 CIRCUIT BREAKERS Note: Accessory modules can only be added to right side pole of solid state SJD and SLD frame circuit breakers. No accessories can be added if mechanical interlock is used. All accessories on this page are useable on superseded JD2, JJ6, JL6, HJ6, SJL, LJ6, LL6, HL6 and SLL circuit breakers. s Built to order. Allow 68 weeks for delivery. 7-130 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Revised on 12/31/19 MD 800A Frame Sentron Series Selection Type MXD6af Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) Continuous Current Rating @ 40°C 2-Poleb Catalog Number 3-Pole Catalog Number 600 MXD62B600n 700 MXD62B700n 800 MXD62B800n MXD63B600 MXD63B700 MXD63B800 Type MD6f Interchangeable Trip Continuous Current Rating Complete Breaker Unassembled with Lugs @ 40°C Catalog Number 2-Pole 600V AC, 250V DCb 500 MD62B500n 600 MD62B600n 700 MD62B700n 800 MD62B800n 3-Pole 600V AC, 500V DCc 500 MD63B500 600 MD63B600 700 MD63B700 800 MD63B800 Frame Only Catalog Number MD62F800n MD63F800 Blue Label Trip Unit Only Catalog Number MD62T500n MD62T600n MD62T700n MD62T800n MD63T500 MD63T600 MD63T700 MD63T800 Lugs d Catalog Number TA2K500 TA3K500 TC2K500 Kits 2TA2N8750 3TA2N8750 2TA3N8750 3TA3N8750 2TA4N8500 3TA4N8500 2TA4P8500 3TA4P8500 Cables Per Lug 1-2 1-3 1-2 Lugs Per Kit 1 1 1 1-2 2 3 1-3 2 3 1-4 2 3 1-4 2 3 Wire Range #1-500 kcmil Cu/Al 1/0-500 kcmil Cu/Al #1-500 kcmil Cu 500-750 kcmil Cu/Al 500-750 kcmil Cu/Al 250-500 kcmil Cu/Al 250-500 kcmil Cu/Al Instantaneous Adjustment Trip Range Ampere Rating 500 600800 Nominal Instantaneous Values Low +/- 20% 2 3 Tolerance 3000 4000 3430 3860 4570 5140 4 4280 5710 5 4710 6280 6 5140 6850 7 5570 7420 High +/- 20% Tolerance 6000 8000 Ordering Information Complete Breaker Unassembled with Lugs Pricing information for MD6 and HMD6 breakers includes frame, trip, and both line and load lugs (TA3K500). When ordered by these catalog numbers, the customer will receive the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of MXD6, HMXD6 and CMD6 include frame with non-interchangeable trip units installed only. Order required lugs separately. For line and load lugs (TA3K500) installed, add suffix "L" to catalog number (add 2 times list price of lugs for each pole). 100% Ratede 3-Pole Only Types MXD6, HMXD6 and CMD6 breakers are available with 100% ratings. To order add suffix "H" to catalog number, and 10% to list price. 100% rated MD breakers require the use of 90°C cable sized at 75°C ampacity and lugs 3TA4P8500 or 3TA2N8750. 50°C Applications see page 7-159. 400Hz Applications see page 7-159. Shipping Weights Number of Poles Number per Shipping Carton Weight (lbs.) MD6, HMD6, HMXD6, CMD6 Complete Breaker Assembled (less lugs) 2 1 53 3 1 61.5 MD6, HMD6 Frame Only 2 1 42.25 3 1 46 MD6, HMD6 Trip Unit Only 2 1 4.5 3 1 6.5 SMD6 Breaker 3 1 61.5 n Built to order. Allow 23 weeks for delivery. aMXD6 circuit breakers are UL Listed for reverse connection applications. b2-pole units available in 3-pole width only. cWhen wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems. d See Note: A, page 7-156. e 80% rated breakers with the CE mark will also be marked in the 100% rated version. f HACRrated. Note: MD frame qualified to UL489 supplement B "NAVAL". See page 7-159 for additional information. Enclosures Type 1 3R 12 Neutral Catalog Number MND61 MND63 MND612n W63623 Modifications page 7-159 Enclosures Section 6 Accessories pages 7-134 and 7-163 to 7-168 MOLDED CASE 7 CIRCUIT BREAKERS Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-131 Molded Case Circuit Breakers MD 800A Frame Sentron Series Type HMXD6ae Black Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) Continuous Current Rating @ 40°C 2-Pole 600V AC/250V DC Catalog Number 3-Pole 600V AC/500V DC Catalog Number 600 For 2-pole application HMXD63B600n 700 use outside poles of HMXD63B700n 800 3-pole circuit breaker HMXD63B800 Type HMD6e Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled w/Lugs Catalog Number 2-Pole 600V AC, 250V DCb 500 HMD62B500n 600 HMD62B600n 700 HMD62B700n 800 HMD62B800n 3-Pole 600V AC, 500V DCd 500 HMD63B500 600 HMD63B600 700 HMD63B700 800 HMD63B800 Frame Only Catalog Number HMD62F800n HMD63F800 Black Label Trip Unit Only Catalog Number MD62T500n MD62T600n MD62T700n MD62T800n MD63T500 MD63T600 MD63T700 MD63T800 Revised on 02/28/22 Selection/Dimensions Type CMD6ae Fuseless Current Limiting Red Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) Continuous Current Rating @ 40°C 2-Pole 600V AC/250V DC Catalog Number 3-Pole 600V AC/500V DC Catalog Number 600 For 2-pole application CMD63B600n 700 use outside poles of CMD63B700n 800 3-pole circuit breaker CMD63B800 Interrupting Ratings Breaker Type MD6, MXD6 HMD6, HMXD6 CMD6 UL 489 AIR--File E10848 IEC 947-2 AIRf RMS Symmetrical Amperes (KA) Volts AC (50/60HZ) Volts AC Volts DC 220/240 380/415 500 240 480 600 250 500 d (lcu) (lcs) (lcu) (lcs) (lcu) (lcs 065 050 25 30 (2-P) 25 (3-P) 065 033 040 20 -- -- 100 065 50 30 (2-P) 50 (3-P) 100 050 065 33 -- -- 200 100 65 -- 50 (3-P) -- -- -- -- -- -- Lug When wire lug shield NDTS is used. Note: NDTS lug shields are required when oversized lugs are used. The kits include the NDTS shield. Dimensions (in inches) Breaker Type W L D MD6, MXD6, HMD6, HMXD6, CMD6, MXD6-ETI, CMD6-ETI, 9 16 6 SMD6-B, SHMD6-B, and SCMD6-B with lug shields 9 24 6 (To Handle) D1 8.25 8.25 MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. n Built to order. Allow 23 weeks for delivery. aHMXD6 and CMD circuit breakers are UL listed for reverse connection applications. b2-pole units available in 3-pole width only. c MXD6-ETI, CMD6-ETI see page 7-143 for catalog information. dW hen wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. e H ACRrated. f Only applicable to non-interchangeable trip unit types: MXD6, HMXD6 7-132 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Revised on 12/31/19 SMD 800A Frame Digital Solid State Sentron Sensitrip IV Series Selection Type SMD6 Blue Label Type SHMD6-B Black Label Current Limiting Type SCMD6-B Red Label Max Current Rating 600 700 800 600 700 800 600 700 800 600 700 800 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SMD6A600LI SMD6A700LI SMD6A800LI SMD6A600LIG SMD6A700LIG SMD6A800LIG SMD6A600LSI SMD6A700LSI SMD6A800LSI SMD6A600LSIG SMD6A700LSIG SMD6A800LSIG Catalog Number (Basic trip unit) SMD6B600LI SMD6B700LI SMD6B800LI SMD6B600LIG SMD6B700LIG SMD6B800LIG SMD6B600LSI SMD6B700LSI SMD6B800LSI SMD6B600LSIG SMD6B700LSIG SMD6B800LSIG SMD 800A Frame 100% Rateda Type SMD6-B Blue Label 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SHMD6A600LI SHMD6A700LI SHMD6A800LI SHMD6A600LIG SHMD6A700LIG SHMD6A800LIG SHMD6A600LSI SHMD6A700LSI SHMD6A800LSI SHMD6A600LSIG SHMD6A700LSIG SHMD6A800LSIG Catalog Number (Basic trip unit) SHMD6B600LI SHMD6B700LI SHMD6B800LI SHMD6B600LIG SHMD6B700LIG SHMD6B800LIG SHMD6B600LSI SHMD6B700LSI SHMD6B800LSI SHMD6B600LSIG SHMD6B700LSIG SHMD6B800LSIG Type SHMD6-B Black Label 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SCMD6A600LI SCMD6A700LI SCMD6A800LI SCMD6A600LIG SCMD6A700LIG SCMD6A800LIG SCMD6A600LSI SCMD6A700LSI SCMD6A800LSI SCMD6A600LSIG SCMD6A700LSIG SCMD6A800LSIG Catalog Number (Basic trip unit) SCMD6B600LI SCMD6B700LI SCMD6B800LI SCMD6B600LIG SCMD6B700LIG SCMD6B800LIG SCMD6B600LSI SCMD6B700LSI SCMD6B800LSI SCMD6B600LSIG SCMD6B700LSIG SCMD6B800LSIG Current Limiting Type SCMD6-B Red Label Max Current Rating 600 700 800 600 700 800 600 700 800 600 700 800 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SMD6A600LIH SMD6A700LIH SMD6A800LIH SMD6A600LIGH SMD6A700LIGH SMD6A800LIGH SMD6A600LSIH SMD6A700LSIH SMD6A800LSIH SMD6A600LSIGH SMD6A700LSIGH SMD6A800LSIGH Catalog Number (Basic trip unit) SMD6B600LIH SMD6B700LIH SMD6B800LIH SMD6B600LIGH SMD6B700LIGH SMD6B800LIGH SMD6B600LSIH SMD6B700LSIH SMD6B800LSIH SMD6B600LSIGH SMD6B700LSIGH SMD6B800LSIGH 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SHMD6A600LIH SHMD6A700LIH SHMD6A800LIH SHMD6A600LIGH SHMD6A700LIGH SHMD6A800LIGH SHMD6A600LSIH SHMD6A700LSIH SHMD6A800LSIH SHMD6A600LSIGH SHMD6A700LSIGH SHMD6A800LSIGH Catalog Number (Basic trip unit) SHMD6B600LIH SHMD6B700LIH SHMD6B800LIH SHMD6B600LIGH SHMD6B700LIGH SHMD6B800LIGH SHMD6B600LSIH SHMD6B700LSIH SHMD6B800LSIH SHMD6B600LSIGH SHMD6B700LSIGH SHMD6B800LSIGH 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SCMD6A600LIH SCMD6A700LIH SCMD6A800LIH SCMD6A600LIGH SCMD6A700LIGH SCMD6A800LIGH SCMD6A600LSIH SCMD6A700LSIH SCMD6A800LSIH SCMD6A600LSIGH SCMD6A700LSIGH SCMD6A800LSIGH Catalog Number (Basic trip unit) SCMD6B600LIH SCMD6B700LIH SCMD6B800LIH SCMD6B600LIGH SCMD6B700LIGH SCMD6B800LIGH SCMD6B600LSIH SCMD6B700LSIH SCMD6B800LSIH SCMD6B600LSIGH SCMD6B700LSIGH SCMD6B800LSIGH Ordering Information Pricing information for all Digital Sentron Series MD frames is for complete breaker only. Price requires lugs or lug kits as separate items. Lugs are suitable for 75°C wire or as noted. Connector wire ranges and cavities are established in conjunction with Table 6.1.4.2.1 of UL 489 standards. Choose actual connector for circuit breakers based on customer requirements. Recommended Terminal Connectors Breaker Frame Ampere Rating Connector or Connector Kit MD 500-600 TA2K500 MD 700-800 TA3K500 Types SMD6-B, SHMD6-B and SCMD6-B are acceptable for reverse connection applications Lugs for 75° C Wireb Catalog Number Cables per Lug TA2K500 2 TA3K500 3 TC2K500 2 Kits (3 lugs/kit) 3TA4N8500 4 3TA4P8500 4 3TA2N8750 2 3TA3N8750 3 Wire Range #1-500 kcmil Cu/Al #1-500 kcmil Cu/Al #1-500 kcmil Cu 250-500 kcmil Cu/Al 250-500 kcmil Cu/Al 500-750 kcmil Cu/Al 500-750 kcmil Cu/Al Each kit contains the following: 3TA4P8500 3 connectors plus 1 NDTS end barrier 3TA3N8750 3 connectors plus 1 NDTS end barrier 3TA2N8750 3 connectors plus 1 NDTS end barrier Trip Unit Adjustable Functions Suffix Letter Code LI LIG LSI LSIG Trip Type LI LIG LSI LSIG Cont Current Setting u u u u Long Time Delay u u u u Instantaneous Pick Up u u u u Short Time Pick Up u u Short Time Delay u u Ground Ground Fault Fault Pick Up Delay u u u u Interrupting Ratings Breaker Type SMD6-B SHMD6-B SCMD6-B RMS Symmetrical kA UL 489 (File E10848) 240V 480V AC AC 600V AC 65 50 25 100 65 50 200 100 65 Neutral Transformers Ampere Rating 600 700 800 Catalog Number N06SMDA N07SMDA N08SMDA Note: "G" suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. All breakers built to order. Allow 2-3 weeks for delivery. a Use 2-3TA4P8500 or 2-3TA3N8750 for 3-pole. These kits are rated for 90°C wire. 90°C cable must be used and sized per 75°C ampacity. b For additional information, see Note: A, page 7-156. c Advanced trip unit equipped with DAS / Maintenance Mode. Requires customer-supplied 24V external power supply, maintenance switch and light. Enclosures Section 6 Accessories pages 7-134 and 7-163 to 7-168 MOLDED CASE 7 CIRCUIT BREAKERS Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-133 Molded Case Circuit Breakers Revised on 08/31/20 Internal Accessories Accessories for: MD/SMD 800A Frame ND/SND 1200A Frame PD/SPD 1600A Frame RD 2000A Frame Shunt Trip Combinations Control Voltage AC DC 120 208 240 277 480 600 012 024 048 125 250 1 Shunt Trip Catalog Number S01MN6 S02MN6s S03MN6 S15MN6s S04MN6s S06MN6s S16MN6s S07MN6 S09MN6s S11MN6 S13MN6s 1 Shunt Trip and 1 Auxiliary Switch Catalog Number S01MN64A -- S03MN64As S15MN64As S04MN64As -- S16MN64As S07MN64A -- S11MN64As S13MN64As Selection S01MN6 Accessory modules can mount in either left hand or right hand poles of all circuit breakers, including solid state. Exception: when mechanical interlock is used. Accessories cannot be mounted in left pole. Undervoltage Trip Combinations Control Voltage 1 Undervoltage Trip 1 Undervoltage Trip and 1 Undervoltage Trip and 1 Auxiliary Switch 2 Auxiliary Switches AC 120 208 240 277 480 600 DC 024 048 125 Catalog Number U01MN6 U02MN6s U03MN6s U15MN6s U04MN6s U06MN6s U07MN6 U09MN6s U11MN6s Catalog Number U01MN64A U02MN64As U03MN64As U15MN64As U04MN64As -- U07MN64A U09MN64As U11MN64As Catalog Number U01MN64AA U02MN64AAs U03MN64AAs U15MN64AAs U04MN64AAs -- U07MN64AA U09MN64AAs U11MN64AAs Auxiliary Switch Combinations Maximum Voltage AC DC 480 250 -- 24 1 Form C Catalog Number A01MN64 A01MNDLVs 2 Form C Catalog Number A02MN64 A02MNDLVs Alarm Switch Combinations Maximum Voltage AC DC 480 250 1 Alarm Switch Catalog Number B00MN64 1 Alarm Switch and 1 Auxiliary Switch Catalog Number A01MN64B 1 Alarm Switch and 2 Auxiliary Switches Catalog Number A02MN64B ETU Testing Unit Breaker Type Description Catalog Number SJD, SLD, SMD, SND, SPD Power Stick Spare cable for Power Stick EPSP18V COMPCA The EPSP18V Power Stick is a hand-held, battery-operated power supply that can be used for trip testing the Sensitrip IV electronic trip units. Requires two 9V batteries. MOLDED CASE 7 CIRCUIT BREAKERS s Built to order. Allow 68 weeks for delivery. 7-134 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Revised on 02/28/22 ND 1200A Frame Sentron Series Selection Type NXD6ah Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) Continuous Current Rating @ 40°C 2-Pole 600V AC/250V DC Catalog Number 3-Pole 600V AC/500V DC Catalog Number 0900 1000 1200 NXD62B900n NXD62B100n NXD62B120n NXD63B900 NXD63B100 NXD63B120 Type ND6h Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled with Lugs Catalog Number 2-Pole 600V AC, 250V DCb 0800 0900 1000 1200 ND62B800n ND62B900n ND62B100n ND62B120 3-Pole 600V AC, 500V DCc 0800 0900 1000 1200 ND63B800 ND63B900 ND63B100 ND63B120 Frame Only Catalog Number ND62F120 ND63F120 Blue Label Trip Unit Only Catalog Number MD62T800n ND62T900n ND62T100n ND62T120 MD63T800 ND63T900 ND63T100 ND63T120 Interrupting Ratings Breaker Type ND6, NXD6 HND6, HNXD6 CND6 RMS Symmetrical Amperes (KA) UL 489 A IR Volts AC Volts DC 240 480 600 250 500 c 65 50 25 30 (2-P) 25 (3-P) 100 65 50 30 (2-P) 50 (3-P) 200 100 65 -- 50 (3-P) IEC 947-2i Volts AC (50/60HZ) 220/240 380/415 (lcu) (lcs) (lcu) (lcs) 65 33 40 20 100 50 65 33 -- -- ---- 500 (lcu) (lcs) -- -- -- -- -- -- Instantaneous Adjustment Trip Range Breaker Ampere Rating 800 900-1200 Nominal Instantaneous Values +20% Tolerance Low 2 3 4 4000 4570 5140 5710 5000 5715 6430 7145 5 6280 7860 6 6850 8575 7 7420 9290 +20% Tolerance High 08000 10000 Ordering Information Complete Breaker Unassembled with Lugs Prices of ND6 and HND6 breakers include frame, trip, and both line and load lugs (3TA4N8500). These catalog numbers are the frame, trip and lugs separately packaged. For applications requiring different lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of NXD6, HNXD6, and CND6 include frame with non-interchangeable trip units installed only. Order required terminal connectors separately. For line and load lugs (3TA4N8500) installed, add suffix "L" to catalog number (add 2 times list price of lug kit). 100% Rated (3-Pole only)g Types NXD6, HNXD6 and CND6 breakers are available with 100% ratings. To order, add suffix "H" to catalog number, and add 10% to list price. 100% rated ND breakers require 90°C cable sized at 75°C ampacity and lug kit 3TA4P8500 or 3TA3N8750. 50°C Applications see page 7-159. 400Hz Applications see page 7-159. Lugs f Catalog Number Cables Wire per Lug Range TA2K500 2 #1-500 kcmil Cu / Al TA3K500 3 #1-500 kcmil Cu / Al TC2K500 2 #1-500 kcmil Cu Kits (2 Kits required per breaker) 2TA4P8500 d 3TA4P8500 d 4 250-500 kcmil Cu / Al 2TA4N8500 e 3TA4N8500 e 4 250-500 kcmil Cu / Al 2TA2N8750 3TA2N8750 2 500-750 kcmil Cu / Al 2TA3N8750 3TA3N8750 3 500-750 kcmil Cu / Al n Built to order. Allow 23 weeks for delivery. aNXD6 circuit breakers are UL listed for reverse connection applications. b2-pole units available in 3-pole width only. cWhen wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500VDC ungrounded UPS systems only. dUse 2 3TA4P8500 kits for 3-pole, or 2 2TA4P8500 kits for 2-pole. Rated for 90° C cable. Use for 100% rated breakers. eUse 2 3TA4N8500 for 3-pole or 2 2TA4N8500 for 2-pole. Rated for 75°C cable. fSee Note: A, page 7-156. g80% rated breakers with the CE mark will also be marked in the 100% rated version. hHACR rated. i Only applicable to non-interchangeable trip unit types: NXD6, HNXD6. Note: ND frame qualified to UL489 supplement B "NAVAL". See page 7-159 for additional information. Enclosures Type 1 3R 12 Neutral Catalog Number MND61 MND63 MND612 n W63623 Modifications page 7-159 Enclosures Section 6 Accessories pages 7-138 and 7-163 to 7-168 Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-135 MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers ND 1200A Frame Sentron Series Type HNXD6ad Black Label Non-Interchangeable Trip (Assembled Circuit Breaker Without Lugs) Continuous Current Rating @ 40°C 2-Pole 600V AC/250V DC Catalog Number 3-Pole 600V AC/500V DC Catalog Number 0900 1000 1200 For 2-pole application use outside poles of 3-pole circuit breaker HNXD63B900 HNXD63B100 HNXD63B120 Type HND6d Black Label Interchangeable Trip Continuous Current Rating @ 40°C Complete Breaker Unassembled with Lugs Catalog Number Frame Only Catalog Number Trip Unit Only Catalog Number 2-Pole 600V AC, 250V DCb 0800 0900 1000 1200 For 2-pole application use outside poles of 3-pole circuit breaker 3-Pole 600V AC, 500V DCc 0800 0900 1000 1200 HND63B800 HND63B900 HND63B100 HND63B120 HND63F120 MD63T800 ND63T900 ND63T100 ND63T120 Type CND6ad Fuseless Current Limiting Red Label Non-Interchangeable Trip (Assembled Circuit Breaker) Continuous Current Rating @ 40°C 2-Pole Catalog Number 3-Pole Catalog Number 0900 1000 1200 For 2-pole application, use outside poles of 3-pole circuit breaker CND63B900n CND63B100 CND63B120 Shipping Weights Number of Poles Number per Shipping Carton Weight (lbs.) ND6, HND6, NXD6, HNXD6, CND6 Assembled Breaker (less terminals) 2 1 53 3 1 61.5 ND6, HND6 Frame Only 2 1 42.25 3 1 46 ND6, HND6 Trip Unit Only 2 1 04.5 3 1 06.5 Revised on 02/06/18 Selection/Dimensions NXD63B120 Lugs When lugs shield NDTS is used. Note: NDTS lug shields are required when oversized lugs TA4P8500 or TA4N8500 are used. The kits include the NDTS shield. Dimensions (in inches) Breaker Type W L ND6, NXD6, HND6, HNXD6, CND6, SND6-B, SHND6-B, 9 16 and SCND6-B with NDTS lug shield 9 24 D D1 6 8.25 6 8.25 MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. n Built to order. Allow 23 weeks for delivery. aHNXD6 and CND6 circuit breakers are UL Listed for reverse connection applications. b2-pole units available in 3-pole width only. c W hen wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. d H ACRrated. 7-136 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Revised on 02/28/19 SND 1200A Frame Digital Solid State Sentron Sensitrip IV Seriesb Selection Type SND6-B Blue Label Type SHND6-B Black Label Max Current Rating 800 1000 1200 800 1000 1200 800 1000 1200 800 1000 1200 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SND6A800LI SND6A100LI SND6A120LI SND6A800LIG SND6A100LIG SND6A120LIG SND6A800LSI SND6A100LSI SND6A120LSI SND6A800LSIG SND6A100LSIG SND6A120LSIG Catalog Number (Basic trip unit) SND6B800LI SND6B100LI SND6B120LI SND6B800LIG SND6B100LIG SND6B120LIG SND6B800LSI SND6B100LSI SND6B120LSI SND6B800LSIG SND6B100LSIG SND6B120LSIG 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SHND6A800LI SHND6A100LI SHND6A120LI SHND6A800LIG SHND6A100LIG SHND6A120LIG SHND6A800LSI SHND6A100LSI SHND6A120LSI SHND6A800LSIG SHND6A100LSIG SHND6A120LSIG Catalog Number (Basic trip unit) SHND6B800LI SHND6B100LI SHND6B120LI SHND6B800LIG SHND6B100LIG SHND6B120LIG SHND6B800LSI SHND6B100LSI SHND6B120LSI SHND6B800LSIG SHND6B100LSIG SHND6B120LSIG SND 1200A Frame 100% Rateda Type SND6-B Type SHND6-B Blue Label Black Label Max Current Rating 800 1000 1200 800 1000 1200 800 1000 1200 800 1000 1200 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SND6A800LIH SND6A100LIH SND6A120LIH SND6A800LIGH SND6A100LIGH SND6A120LIGH SND6A800LSIH SND6A100LSIH SND6A120LSIH SND6A800LSIGH SND6A100LSIGH SND6A120LSIGH Catalog Number (Basic trip unit) SND6B800LIH SND6B100LIH SND6B120LIH SND6B800LIGH SND6B100LIGH SND6B120LIGH SND6B800LSIH SND6B100LSIH SND6B120LSIH SND6B800LSIGH SND6B100LSIGH SND6B120LSIGH 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SHND6A800LIH SHND6A100LIH SHND6A120LIH SHND6A800LIGH SHND6A100LIGH SHND6A120LIGH SHND6A800LSIH SHND6A100LSIH SHND6A120LSIH SHND6A800LSIGH SHND6A100LSIGH SHND6A120LSIGH Catalog Number (Basic trip unit) SHND6B800LIH SHND6B100LIH SHND6B120LIH SHND6B800LIGH SHND6B100LIGH SHND6B120LIGH SHND6B800LSIH SHND6B100LSIH SHND6B120LSIH SHND6B800LSIGH SHND6B100LSIGH SHND6B120LSIGH Current Limiting Type SCND6-B Red Label 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SCND6A800LI SCND6A100LI SCND6A120LI SCND6A800LIG SCND6A100LIG SCND6A120LIG SCND6A800LSI SCND6A100LSI SCND6A120LSI SCND6A800LSIG SCND6A100LSIG SCND6A120LSIG Catalog Number (Basic trip unit) SCND6B800LI SCND6B100LI SCND6B120LI SCND6B800LIG SCND6B100LIG SCND6B120LIG SCND6B800LSI SCND6B100LSI SCND6B120LSI SCND6B800LSIG SCND6B100LSIG SCND6B120LSIG Current Limiting Type SCND6-B Red Label 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SCND6A800LIH SCND6A100LIH SCND6A120LIH SCND6A800LIGH SCND6A100LIGH SCND6A120LIGH SCND6A800LSIH SCND6A100LSIH SCND6A120LSIH SCND6A800LSIGH SCND6A100LSIGH SCND6A120LSIGH Catalog Number (Basic trip unit) SCND6B800LIH SCND6B100LIH SCND6B120LIH SCND6B800LIGH SCND6B100LIGH SCND6B120LIGH SCND6B800LSIH SCND6B100LSIH SCND6B120LSIH SCND6B800LSIGH SCND6B100LSIGH SCND6B120LSIGH Trip Unit Adjustable Functions Suffix Letter Code LI LIG LSI LSIG Trip Type LI LIG LSI LSIG Cont Current Setting u u u u Long Time Delay u u u u Instantaneous Pick Up u u u u Short Time Pick Up u u Short Time Fixed Pick Up u u Short Time I2t Delay u u Ground Fault Pick Up Ground Fault Delay u u u u Interrupting Ratings Neutral Transformers Breaker Type SND6-B SHND6-B SCND6-B RMS Symmetrical kA UL 489 (File E10848) 240V AC 480V AC 600V AC 65 50 25 100 65 50 200 100 65 Ampere Rating 800 1000 1200 Catalog Number N08SMDA N10SNDA N12SNDA MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. For ordering information and terminal connectors, and enclosures, see page 7-135. Note: "G" suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. All breakers built to order. Allow 23 weeks for delivery. a Use 2-3TA4P8500 or 2-3TA3N8750 for 3-pole. These kits are rated for 90°C wire. 90°C cable must be used and sized per 75°C ampacity. b SND6, SHND6 and SCND6 circuit breakers are UL Listed for reverse connection applications. c Advanced trip unit equipped with DAS / Maintenance Mode. Requires customer-supplied 24V external power supply, maintenance switch and light. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-137 Molded Case Circuit Breakers Revised on 08/31/20 Internal Accessories Accessories for: MD/SMD 800A Frame ND/SND 1200A Frame PD/SPD 1600A Frame RD 2000A Frame Shunt Trip Combinations Control Voltage AC DC 120 208 240 277 480 600 012 024 048 125 250 1 Shunt Trip Catalog Number S01MN6 S02MN6s S03MN6 S15MN6s S04MN6s S06MN6s S16MN6s S07MN6 S09MN6s S11MN6 S13MN6s 1 Shunt Trip and 1 Auxiliary Switch Catalog Number S01MN64A -- S03MN64As S15MN64As S04MN64As -- S16MN64As S07MN64A -- S11MN64As S13MN64As Selection S01MN6 Accessory modules can mount in either left hand or right hand poles of all circuit breakers, including solid state. Exception: when mechanical interlock is used. Accessories cannot be mounted in left pole. Undervoltage Trip Combinations Control Voltage 1 Undervoltage Trip 1 Undervoltage Trip and 1 Undervoltage Trip and 1 Auxiliary Switch 2 Auxiliary Switches AC 120 208 240 277 480 600 DC 024 048 125 Catalog Number U01MN6 U02MN6s U03MN6s U15MN6s U04MN6s U06MN6s U07MN6 U09MN6s U11MN6s Catalog Number U01MN64A U02MN64As U03MN64As U15MN64As U04MN64As -- U07MN64A U09MN64As U11MN64As Catalog Number U01MN64AA U02MN64AAs U03MN64AAs U15MN64AAs U04MN64AAs -- U07MN64AA U09MN64AAs U11MN64AAs Auxiliary Switch Combinations Maximum Voltage AC DC 480 250 -- 24 1 Form C Catalog Number A01MN64 A01MNDLVs 2 Form C Catalog Number A02MN64 A02MNDLVs Alarm Switch Combinations Maximum Voltage AC DC 480 250 1 Alarm Switch Catalog Number B00MN64 1 Alarm Switch and 1 Auxiliary Switch Catalog Number A01MN64B 1 Alarm Switch and 2 Auxiliary Switches Catalog Number A02MN64B ETU Testing Unit Breaker Type Description Catalog Number SJD, SLD, SMD, SND, SPD Power Stick Spare cable for Power Stick EPSP18V COMPCA The EPSP18V Power Stick is a hand-held, battery-operated power supply that can be used for trip testing the Sensitrip IV electronic trip units. Requires two 9V batteries. MOLDED CASE 7 CIRCUIT BREAKERS s Built to order. Allow 68 weeks for delivery. 7-138 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers PD 1600A Frame Sentron Series Type PXD6 b Non-Interchangeable Trip e 3-Pole 600V AC, 250-500V DCa Continuous Current Rating @ 40°C 1200 1400 1600 Complete Breaker Assembled (Frame/Trip Unit Only) Mounting Assembly Catalog Number Catalog Number PXD63B120n MB9301 PXD63B140n -or- PXD63B160 MBR9302 Blue Label Lugs (6 required) Catalog Number TA5P600 Type PD6 Interchangeable Tripe 3-Pole 600V AC, 250-500V DCa Continuous Current Rating @ 40°C 1200 1400 1600 Complete Breaker Unassembled Frame Only Catalog Number Catalog Number PD63B120n PD63B140 PD63F160 PD63B160 Trip Unit Only Catalog Number PD63T120n PD63T140 PD63T160 Mounting Assembly Catalog Number MB9301 -or- MBR9302 Blue Label Lugs (6 required) Catalog Number TA5P600 Type HPXD6b Non-Interchangeable Tripe 3-Pole 600V AC, 250-500V DCa Blue Label Continuous Current Rating @ 40°C 1200 1400 1600 Complete Breaker Assembled (Frame/Trip Unit Only) Catalog Number HPXD63B120n HPXD63B140n HPXD63B160 Type HPD6 Interchangeable Tripe 3-Pole 600V AC, 250-500V DCa Continuous Current Rating @ 40°C 1200 1400 1600 Complete Breaker Unassembled Frame Only Catalog Number Catalog Number HPD63B120n HPD63B140 HPD63F160 HPD63B160 Trip Unit Only Catalog Number PD63T120n PD63T140 PD63T160 Mounting Assembly Catalog Number MB9301 -or- MBR9302 Black Label Lugs (6 required) Catalog Number TA5P600 Type CPD6 Non-Interchangeable Tripe Fuseless Current Limiting 3-Pole 600V AC, 250-500V DCa Red Label Continuous Current Rating @ 40°C 1200 1400 1600 Complete Breaker Assembled (Frame/Trip Unit Only) Catalog Number CPD63B120n CPD63B140n CPD63B160n Selection Ordering Instructions Complete Breaker Unassembled with Lugs Prices of PD6, HPD6, RD6, and HRD6 type breakers include frame, trip, mounting base (MB9301), and both line and load lugs (PD Frame TA5P600, RDFrame TC5R600). When ordered by these catalog numbers, the customer will receive the frame, trip, mounting assembly and lugs separately packaged. For applications requiring different mounting base or lugs, order individual items as needed. Complete Breaker Assembled without Lugs Prices of PXD6, HPXD6, RXD6, HRXD6 and CPD6 type breakers include frame with non-interchangeable trip unit installed only. Order required mounting base and lugs separately. 100% Rated (3-Pole only) Types PXD6, HPXD6 breakers are available with 100% ratings. To order add suffix "H" to catalog number, and 10% to list price. 100% PD breakers require 90° C cable sized at 75° C ampacity and TC5R600 lugs. RD 2000A Frames not available with 100% ratings. 50°C Applications see page 7-159. 400HZ Applications see page 7-159. Lugs (6 required per breaker)d Catalog Number No of Cables per Connector TA5P600 1-5 TC5R600 1-5 TA4P750s 1-4 TA6R600 1-6 Wire Range 300-600 kcmil Cu/Al 300-600 kcmil Cu only 600-750 kcmil Cu/Al 300-600 kcmil Cu/Al MOLDED CASE 7 CIRCUIT BREAKERS Interrupting Ratings Breaker Type UL 489 A IR RMS Symmetrical KA Volts AC 240 480 600 PD6, PXD6 65 50 25 HPD6, HPXD6 100 65 50 CPD6 200 100 65 Volts DC a 250 500 30 (2P) 25 (3P) 30 (2P) 50 (3P) 30 (2P) 50 (3P) n Built to order. Allow 23 weeks for delivery. s Built to order. Allow 68 weeks for delivery. aUse two outside poles of a 3-pole circuit breaker for 250V b W hen wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. c PXD6, HPXD6 and CPD6 type circuit breakers are UL Listed for reverse feed applications. dFor additional information See Note: A, page 7-156. e HACRrated. Note: PD frame qualified to UL489 supplement B "NAVAL". See page 7-159 for additional information. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-139 Molded Case Circuit Breakers SPD 1600A Frame Digital Solid State Sentron Sensitrip IV Series Type SPD6-B Blue Label Type SHPD6-B Black Label Max Current Rating 1400 1600 1400 1600 1400 1600 1400 1600 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SPD6A140LI SPD6A160LI SPD6A140LIG SPD6A160LIG SPD6A140LSI SPD6A160LSI SPD6A140LSIG SPD6A160LSIG Catalog Number (Basic trip unit) SPD6B140LI SPD6B160LI SPD6B140LIG SPD6B160LIG SPD6B140LSI SPD6B160LSI SPD6B140LSIG SPD6B160LSIG 3-Pole, 600V AC Catalog Number (Advanced trip unit)c SHPD6A140LI SHPD6A160LI SHPD6A140LIG SHPD6A160LIG SHPD6A140LSI SHPD6A160LSI SHPD6A140LSIG SHPD6A160LSIG Catalog Number (Basic trip unit) SHPD6B140LI SHPD6B160LI SHPD6B140LIG SHPD6B160LIG SHPD6B140LSI SHPD6B160LSI SHPD6B140LSIG SHPD6B160LSIG Trip Unit Adjustable Functions Suffix Letter Code LI LIG LSI LSIG Trip Type LI LIG LSI LSIG Cont Current Setting u u u u Long Time Delay u u u u Instantaneous Pick Up u u u u Short Time Pick Up u u Short Time Fixed Delay u u Short Time l2t Delay u u Ground Ground Fault Fault Pick Up Delay u u u u Interrupting Ratings Breaker Type SPD6-B RMS Symmetrical kA UL 489 240V AC 480V AC 65 50 SHPD6-B 100 65 600V AC 25 50 Mounting Block (Required)b Catalog Number MB9301 MBR9302 Revised on 05/31/18 Selection/Dimensions Ordering Information Pricing information for all Digital Sentron Series PD frame unit is for breaker only. Price required mounting block assembly and necessary terminal connectors as separate items. SPD6-B and SHPD6-B are acceptable for reverse connection applications. Lugsa Catalog Number TA5P600 TC5R600 TA6R600 No. of cables per con- Wire nector Range 1-5 pcs. 300-600 kcmil Cu/Al 1-5 pcs. 300-600 kcmil Cu Only 1-6 pcs. 300-600 kcmil Cu/Al Neutral Transformers Ampere Rating 1400 1600 Catalog Number N14SPD N16SPD Enclosure Type 1 Catalog Number PRD6N1 All PD, RD Frames: MOLDED CASE 7 CIRCUIT BREAKERS MB9301 (shown) MBR9302 MBR9302 MB9301 MBR9302 MB9301 For inches / millimeters conversion, see Application Data section. Note: "G" suffix in catalog number denotes circuit breaker for 3-phase, 3-wire circuits. For 3-phase, 4-wire, order correct 4th wire (neutral) transformer as separate and additional item. All breakers built to order. Allow 23 weeks for delivery. a For additional information, see Note: A, page 7-156. b The PD frame circuit breaker requires the use of a connect-all mounting assembly to allow for placing into service. 7-140 Siemens Industry, Inc. SPEEDFAXTM Product Catalog c Advanced trip unit equipped with DAS / Maintenance Mode. Requires customer-supplied 24V external power supply, maintenance switch and light. Product Category MCCB Molded Case Circuit Breakers Revised on 08/31/20 Internal Accessories Accessories for: MD/SMD 800A Frame ND/SND 1200A Frame PD/SPD 1600A Frame RD 2000A Frame Shunt Trip Combinations Control Voltage AC DC 120 208 240 277 480 600 012 024 048 125 250 1 Shunt Trip Catalog Number S01MN6 S02MN6s S03MN6 S15MN6s S04MN6s S06MN6s S16MN6s S07MN6 S09MN6s S11MN6 S13MN6s 1 Shunt Trip and 1 Auxiliary Switch Catalog Number S01MN64A -- S03MN64As S15MN64As S04MN64As -- S16MN64As S07MN64A -- S11MN64As S13MN64As Selection S01MN6 Accessory modules can mount in either left hand or right hand poles of all circuit breakers, including solid state. Exception: when mechanical interlock is used. Accessories cannot be mounted in left pole. Undervoltage Trip Combinations Control Voltage 1 Undervoltage Trip 1 Undervoltage Trip and 1 Undervoltage Trip and 1 Auxiliary Switch 2 Auxiliary Switches AC 120 208 240 277 480 600 DC 024 048 125 Catalog Number U01MN6 U02MN6s U03MN6s U15MN6s U04MN6s U06MN6s U07MN6 U09MN6s U11MN6s Catalog Number U01MN64A U02MN64As U03MN64As U15MN64As U04MN64As -- U07MN64A U09MN64As U11MN64As Catalog Number U01MN64AA U02MN64AAs U03MN64AAs U15MN64AAs U04MN64AAs -- U07MN64AA U09MN64AAs U11MN64AAs Auxiliary Switch Combinations Maximum Voltage AC DC 480 250 -- 24 1 Form C Catalog Number A01MN64 A01MNDLVs 2 Form C Catalog Number A02MN64 A02MNDLVs Alarm Switch Combinations Maximum Voltage AC DC 480 250 1 Alarm Switch Catalog Number B00MN64 1 Alarm Switch and 1 Auxiliary Switch Catalog Number A01MN64B 1 Alarm Switch and 2 Auxiliary Switches Catalog Number A02MN64B ETU Testing Unit Breaker Type Description Catalog Number SJD, SLD, SMD, SND, SPD Power Stick Spare cable for Power Stick EPSP18V COMPCA The EPSP18V Power Stick is a hand-held, battery-operated power supply that can be used for trip testing the Sensitrip IV electronic trip units. Requires two 9V batteries. MOLDED CASE 7 CIRCUIT BREAKERS s Built to order. Allow 68 weeks for delivery. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-141 Molded Case Circuit Breakers RD 2000A Frame Sentron Series Type RXD6d 3-Pole 600V AC, 250-500V DCa Blue Label Non-Interchangeable Trip (Assembled Circuit Breaker Only Without Lugs) Continuous Current Rating @ 40°C Complete Breaker Assembled (Frame/Trip Unit Only) Mounting Assembly Catalog Number Catalog Number Lugs (6 required) Catalog Number 1600 RXD63B160 MB9301 1800 RXD63B180 -or- TC5R600 2000 RXD63B200 MBR9302 Type RD6d 3-Pole 600V AC, 250-500V DCa Blue Label Interchangeable Trip (Unassembled Circuit Breaker with Lugs) Continuous Current Rating @ 40°C 1600 1800 2000 Complete Breaker Unassembled Frame Only Catalog Number Catalog Number RD63B160n RD63B180 RD63F200 RD63B200 Trip Unit Only Catalog Number RD63T160n RD63T180 RD63T200 Mounting Assembly Catalog Number MB9301 -orMBR9302 Lugs (6 required) Catalog Number TC5R600 Type HRXD6d Continuous Current Rating @ 40°C 1600 1800 2000 Black Label Complete Breaker Assembled (Frame/Trip Unit Only) Catalog Number HRXD63B160n HRXD63B180n HRXD63B200 Type HRD6d Continuous Current Rating @ 40°C 1600 1800 2000 Complete Breaker Unassembled Frame Only Catalog Number Catalog Number HRD63B160n HRD63B180 HRD63F200 HRD63B200 Trip Unit Only Catalog Number RD63T160n RD63T180 RD63T200 Mounting Assembly Catalog Number MB9301 -or- MBR9302 Interrupting Ratings Breaker Type RD6, RXD6 HRD6, HRXD6 UL 489 A IR RMS Symmetrical KA Volts AC 240 480 600 65 50 25 100 65 50 Volts DC a 250 500 30 (2P) 25 (3P) 30 (2P) 50 (3P) Black Label Lugs (6 required) Catalog Number TC5R600 Instantaneous Adjustment Trip Range (PD / RD Frames) Breaker Ampere Rating 1200-2000 Nominal Instantaneous Values +20% Tolerance Low 2 3 4 5000 5715 6430 7145 5 7860 6 7 8575 9790 +20% Tolerance High 10,000 Selection RXD63B200 Mounting Block Catalog Number MB9301 MBR9302 Connection Points Front Rear Shipping Weights Number of Poles Number per Shipping Carton Weight (lbs.) PXD6, HPXD6, RXD6, HRXD6, CPD6 Assembled Breakers 3 1 61.5 PD6, HPD6, RD6, HRD6 Frame Only 3 1 55.0 PD6, RD6 Trip Unit Only 3 1 06.5 Mounting Assembly MB9301 1 53.0 MBR9302 1 50.9 Lugs (6 required per breaker)e Catalog Number TC5R600 TA6R600 No of Cables per Connector 1-5 1-6 Wire Range 300-600 kcmil Cu only 300-600 kcmil Cu/Al MOLDED CASE 7 CIRCUIT BREAKERS n Built to order. Allow 23 weeks for delivery. s Built to order. Allow 68 weeks for delivery. aUse two outside poles of a 3-pole circuit breaker for 250V DC applications. b When wired as shown on page 7-4, this circuit breaker is UL listed and rated for use on 500V DC ungrounded UPS systems only. c RXD6 and HRXD6 type circuit breakers are UL Listed for reverse feed applications. d HACR rated. e For additional information See Note: A, page 7-156. Note: RD frame qualified to UL489 supplement B "NAVAL". See page 7-159 for additional information. For required mounting base (MB9301 or MBR9302) see page 7-140. 7-142 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Revised on 02/28/19 Magnetic Trip Only -- ETI Motor Circuit Protector Selection Breaker Type ED6-A 600V AC 250V DC CED6-A 600V AC 250V DC FXD6d 600V AC 250V DC CFD6d 600V AC 250V DC JXD6(A)a 600V AC 250V DC CJD6a 600V AC 250V DC LXD6(A)a 600V AC 250V DC CLD6a 600V AC 250V DC LMXD6d 600V AC 250V DC MXD6d 600V AC 250V DC CMD6d 600V AC 250V DC Ampere Rating 001 002 003 005 010 025 030 040 050 100 125 SHIPPING: 001 002 003 005 010 025 030 040 050 100 125 SHIPPING: 150 150 150 250 SHIPPING: 150 150 150 250 SHIPPING: 400 400 SHIPPING: 400 400 SHIPPING: 600 600 SHIPPING: 600 600 SHIPPING: 800 800 SHIPPING: 800 800 800 SHIPPING: 800 800 800 SHIPPING: Instantaneous Trip Rangeb Minimumc 002.6 007 010 016 030 055 080 115 180 315 500 Maximumc 00009 00022 00035 00054 00100 00180 00270 00375 00600 01000 01250 002.6 007 010 016 030 055 080 115 180 315 500 00009 00022 00035 00054 00100 00180 00270 00375 00600 01000 01250 0400 0800 1100 1100 00800 01500 02500 02500 0400 0800 1100 1100 00800 01500 02500 02500 1250 2000 02500 04000 1250 2000 02500 04000 2000 3000 04000 06000 2000 3000 04000 06000 2800 3200 06000 08000 3000 4000 5000 3000 4000 5000 06000 08000 10000 06000 08000 10000 Complete Circuit Breaker Without Lugse Catalog Number 2-Pole Catalog Number 3-Pole -- ED63A001 -- ED63A002 -- ED63A003 -- ED63A005 -- ED63A010 -- ED63A025 -- ED63A030 -- ED63A040 -- ED63A050 -- ED63A100 -- ED63A125 03.8 lbs. each -- CED63A001n -- CED63A002n -- CED63A003n -- CED63A005n -- CED63A010n -- CED63A025n -- CED63A030n -- CED63A040n -- CED63A050n -- CED63A100n -- CED63A125n 06 lbs. each -- FXD63L150n -- FXD63A150 -- FXD63H150 -- FXD63A250 09 lbs. each -- CFD63L150n -- CFD63A150n -- CFD63H150n -- CFD63A250n 12 lbs. each 12 lbs. each -- JXD63L400 JXD62H400n JXD63H400 16 lbs. each 20 lbs. each -- CJD63L400n -- CJD63H400n 29.5 lbs. each 31.5 lbs. each LXD62L600n LXD63L600n -- LXD63H600 16 lbs. each 20 lbs. each -- CLD63L600n -- CLD63H600n 31.5 lbs. each -- LMXD63L800n -- LMXD63A800 35 lbs. each -- MXD63L800n -- MXD63A800n -- MXD63H800 33 lbs. each -- CMD63L800n -- CMD63A800n -- CMD63H800n 80 lbs. each Important Information ETI interrupting ratings are determined through combination tests with properly sized overload relays and contactors. e Connectors included when ordering by circuit breaker catalog number for HEM, ED and CED6 ETIs. Order ETI circuit breaker and lugs (2 per pole) separately for the FXD6, CFD6, MXD6, CMD6, JXD6, CJD6, LXD6 and CLD6 ETI's. Lug Information pages 7-156 to 7-158 Enclosures Section 6 Accessories pages 7-163 to 7-168 Application data pages 7-144 to 7-145 n Built to order. Allow 23 weeks for delivery. a 2-pole available in 3-pole width only. b When applied on DC Circuits -- Trip levels will increase approximately +15 to 20%. c Tolerance -20%/+30% for lowest setting. All other set- tings are -20%/+20% d For 2-pole application use outside poles of 3-pole circuit breaker. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-143 MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers Revised on 02/28/19 Motor Circuits Application General Protection of Motor Circuits Molded case circuit breakers are used in motor circuits as a disconnecting means and for short-circuit protection. They should be used in conjunction with motor-running, over-current-protection devices, and should permit the motor to start without nuisance tripping from motor-inrush current. The circuit breaker should have a continuous-current rating of not less than 115% of the motor full-load current. The recommended motor circuit protectors (Siemens ETI instantaneous only circuit breakers) listed have continuous-current ratings of at least 115% of motor full-load currents. The trip-setting positions are approximately 11 times motor full-load currents. The suggested trip settings may have to be adjusted upward to no higher than 1300% of full-load current for non-design E type motors, and no greater than 1700% of full load current for design E motors, to allow for motor start-up due to inrush currents. Breaker Mounted Immediately Ahead of Motor Starter Siemens ETI motor circuit protectors are recommended for use in combination motor starters to provide selective short-circuit protection for the motor branch circuit. The adjustable instantaneous-trip feature of the Siemens ETI motor circuit protector provides for a trip setting slightly above the peak motor-inrush current. With this setting, no delay is introduced in opening the circuit when a fault occurs. This circuit breaker has no time-delay trip element. Therefore it must be used in conjunction with, and immediately ahead of, the motor-running overcurrent protective device. Important: The information below does not apply to all motor applications: it is recommended that the user refer to the National Electrical Code (NEC) for specific needs. Table 1 (When Breaker is Mounted Immediately Ahead of Motor Starter) 3-Phase Induction Type Motors (Siemens ETI motor circuit protectors for branch circuit use with alternating-current combination, full voltage motor starters). Motor Full Load Amperes Catalog Number .20 .34 .46 .57 .69 .33 .45 .56 ED63A001 .68 CED63A001 .81 .53 .84 1.15 1.46 1.69 .83 1.14 1.45 ED63A002 1.68 CED63A002 2.00 .76 1.30 1.76 2.30 2.69 1.29 1.75 2.29 ED63A003 2.68 CED63A003 3.18 1.23 2.00 2.76 3.53 4.15 1.99 2.75 3.52 ED63A005 4.14 CED63A005 4.90 2.30 3.84 5.38 6.53 7.69 3.83 5.37 6.52 ED63A010 7.68 CED63A010 9.10 4.23 6.91 6.92 9.61 9.62 11.91 ED63A025 11.92 13.83 CED63A025 13.84 16.40 6.15 10.37 10.38 14.22 14.23 18.06 ED63A030 18.07 20.75 CED63A030 20.76 24.50 ETI Trip Setting Adjustment Amperes Low 2.6 2 4.5 3 6 4 7.5 High 9 Low 7 2 11 3 15 4 19 High 22 Low 10 2 17 3 23 4 30 High 35 Low 16 2 26 3 36 4 46 High 54 Low 30 2 50 3 70 4 85 High 100 Low 55 2 90 3 125 4 155 High 180 Low 80 2 135 3 185 4 235 High 270 Motor Full Catalog Load Amperes Number 8.84 14.23 19.61 25.00 28.84 14.22 19.60 24.99 28.83 34.00 ED63A040 CED63A040 13.84 23.07 31.53 40.00 46.15 23.06 31.52 39.99 46.14 54.50 ED63A050 CED63A050 24.23 41.53 56.92 68.46 76.92 41.52 56.91 68.45 76.91 90.90 ED63A100 CED63A100 38.46 55.37 55.38 70.75 70.76 84.60 84.61 96.14 96.15 113.60 ED63A125 CED63A125 30.76 35.38 44.51 53.84 58.46 63.07 35.37 39.99 49.23 58.45 63.06 74.50 FXD63L150 CFD63L150 61.53 69.22 69.23 76.91 84.61 92.29 100.00 108.00 108.00 115.00 115.00 136.00 FXD63A150 CFD63A150 85.00 100.00 100.00 115.00 131.00 146.00 162.00 177.00 177.00 192.00 192.00 227.00 FXD63A250 CFD63A250 ETI Trip Setting Adjustment Amperes Low 115 2 185 3 255 4 325 High 375 Low 180 2 300 3 410 4 520 High 600 Low 2 3 4 High 315 540 740 890 1000 Low 2 3 4 High 500 720 920 1100 1250 Low 400 2 460 4 580 6 700 7 760 High 820 Low 2 4 6 7 High 800 900 1100 1300 1400 1500 Low 2 4 6 7 High 1100 1300 1700 2100 2300 2500 Motor Full Catalog Load Amperes Number 95.00 110.00 110.00 124.00 138.00 151.00 165.00 178.00 178.00 192.00 192.00 227.00 JXD63L400 CJD63L400 154.00 176.00 176.00 198.00 220.00 242.00 264.00 285.00 285.00 308.00 308.00 326.00 JXD63H400 CJD63H400 155.00 176.00 176.00 198.00 220.00 242.00 264.00 285.00 285.00 308.00 308.00 326.00 LXD63L600 CLD63L600 231.00 264.00 264.00 292.00 330.00 362.00 395.00 428.00 428.99 462.00 462.00 490.00 LXD63H600 CLD63H600 215.00 238.00 238.00 261.00 261.00 284.00 308.00 369.00 369.00 423.00 423.00 462.00 462.00 490.00 LMXD63L800 246.00 269.00 269.00 284.00 284.00 323.00 362.00 492.00 492.00 562.00 562.00 616.00 616.00 660.00 LMXD63A800 231.00 264.00 264.00 292.00 292.00 330.00 362.00 395.00 428.00 462.00 462.00 490.00 MXD63L800 CMD63L800 308.00 352.00 352.00 442.00 442.00 447.00 483.00 527.00 571.00 616.00 616.00 660.00 MXD63A800 CMD63A800 385.00 440.00 495.00 550.00 605.00 660.00 660.00 695.00 MXD63H800 CMD63H800 ETI Trip Setting Adjustment Amperes Low 2 4 6 7 High 1250 1430 1790 2140 2320 2500 Low 2 4 6 7 High 2000 2290 2860 3430 3710 4000 Low 2 4 6 7 High 2000 2290 2860 3430 3710 4000 Low 2 4 6 7 High 3000 3430 4290 5140 5570 6000 Low 2 3 5 6 7 High 2800 3100 3400 4000 4800 5500 6000 Low 2 3 5 6 7 High 3200 3500 3700 4700 6400 7300 8000 Low 2 3 5 7 High 3000 3430 3800 4710 5570 6000 Low 2 3 5 7 High 4000 4570 5740 6280 7240 8000 Low 3 5 6 5000 6430 7860 8575 MOLDED CASE 7 CIRCUIT BREAKERS Note: Lowest instantaneous settings have a -20%/+30% tolerance and all other settings have a -20%/+20% tolerance. 7-144 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Motor Circuits Application Breaker Mounted at a Distance From Motor Starter ET thermal-magnetic circuit breakers conform to the National Electrical Code table 430-52 requirements for motor branch and feeder circuit protection when properly applied in conjunction with motor-running overcurrent protective devices. The recommended circuit-breaker ratings in Table 2 provide adequate time delay for starting the majority of three phase induction motors. To determine the ampere ratings of the ET breaker to protect a motor feeder, add the rating of the ET breaker used to protect the largest motor branch circuit in the group to the full-load currents of the remaining motors in the group. Interrupt Ratings For normal commercial purposes, available fault current can conveniently be obtained in the Interrupting Selector Tables. Table 2 (When Breaker is Mounted at a Distance From Motor Starter) 3-Phase Induction Type Motors (EQ and ET circuit breakers (thermal-magnetic trip) for branch breaker use with alternating-current combination motor starters). Motor Horsepower Rating 0001/2 0003/4 001 0011/2 002 003 005 0071/2 010 015 020 025 030 040 050 060 075 100 125 150 200 250 300 350 400 500 200 and 208V Motors 230V Motors 240V Circuit Breaker Dataa 240V Circuit Breaker Data a Breaker Catalog Type Number Ampere Breaker Catalog Rating Type Number Ampere Rating BQ b BQ3B015 015 BQ3B015 015 BQ3B015 015 BQ3B015 015 BQ3B015 BQ3B015 015 015 BQ b BQ3B015 BQ3B015 015 015 BQ3B020 020 BQ3B015 015 BQ3B030 030 BQ3B020 020 BQ b BQ3B040 040 BQ3B030 030 BQ3B060 060 BQ3B050 050 BQ3B070 070 BQ b BQ3B070 070 BQ3B100 100 BQ3B090 090 BQ3B100 100 FXD6 FXD63B125 125 FXD63B150 150 FXD63B175 175 FXD63B200 200 FXD63B225 225 FXD6 FXD63B125 125 FXD63B150 150 FXD63B175 175 FXD63B200 200 JXD2 JXD23B300 300 -- -- -- JXD2 JXD23B400 400 JXD2 JXD23B350 350 JXD2 LD6 c or LMD6 LD6 c or LMD6 LMD6 -- -- JXD23B400 400 LD63B600 LMD63B600 600 LD63B600 or LMD63B600 600 LMD63B800 800 -- -- -- -- JXD2 JXD23B400 400 LD6 c or LMD6 LD63B500 or LMD63B500 500 LMD6 LD63B600 or LMD63B600 600 LMD6 -- LMD63B800 800 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 460V Motors 480V Circuit Breaker Data a Breaker Type Catalog Number Ampere Rating ED43B015 015 ED43B015 015 ED4 ED43B015 015 ED43B015 015 ED43B015 015 ED43B015 015 ED43B015 015 ED43B030 030 ED4 ED43B030 030 ED43B040 040 ED43B050 050 FXD6 FXD63B090 090 FXD63B100 100 FXD63B125 125 FXD63B150 150 FXD6, FD6 FXD63B150 150 FXD6, FD6 FXD63B200 200 FD6 c JD6 c FD63B250 250 JD63B250 250 JD6 c JD63B300 300 JD6 c JD6 c JD6 c LD6 c or LMD6 LMD6 LMD6 -- JD63B300 300 JD63B350 350 JD63B400 400 LD63B600 or LMD63B600 600 LMD63B700 700 LMD63B800 800 -- -- 575V Motors 600V Circuit Breaker Data a Breaker Type Catalog Number Ampere Rating ED63B015 015 ED63B015 015 ED6 ED63B015 015 ED63B015 015 ED63B015 015 ED63B015 015 ED63B015 015 ED63B020 020 ED6 ED63B030 030 ED63B035 035 ED63B050 050 FXD6 FXD63B060 060 FXD63B070 070 FXD63B090 090 FXD63B100 100 FXD6 FXD63B100 100 FXD6, FD6 FXD63B125 125 FXD6, FD6 FD63B175 175 FXD6, FD6 FXD63B200 200 OR JD6 c JD63B200 200 FXD6 or FXD63B225 225 JD6 c JD63B225 225 JD6 c JD6 c JD63B300 300 JD63B400 400 JD6 c JD63B400 400 LD6 c or LMD6 LD6 c or LMD6 LMD6 LD63B500 or LMD63B500 500 LD63B600 or LMD63B600 600 LMD63B800 800 MOLDED CASE 7 CIRCUIT BREAKERS aThe selection of breakers for this table is in accordance with Article 430, 2005 National Electric Code. Recommended circuit breakers are for full voltage starting, special consideration is necessary for reduced voltage starting. bFor panelboard applications, substitute the BL breaker for the BQ, ED2 circuit breakers may also be used. cFor non-interchangeable trip applications, substitute the FXD6 for the FD6, the JXD6 for the JD6, or the LXD6 for the LD6. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-145 Molded Case Circuit Breakers Revised on 02/28/19 Adjustable Installments Magnetic Trip Settings Application Breaker Type ED6 CED6 FXD6-A FD6-A HFD6 HHFD6 CFD6 Maximum Continuous Amperes 1 2 3 5 10 25 30 40 50 100 125 1 2 3 5 10 25 30 40 50 100 125 70 80 90 100 110 125 150 150 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 175 200 225 250 70 80 90 100 110 125 150 150 150 175 200 225 250 Nominal AC Adjustable Trip Range Low 2 3 4 2.6 4.5 6 7.5 7 11 15 19 10 17 23 30 16 26 36 46 30 50 70 85 55 90 125 155 80 135 185 235 115 185 255 325 180 300 410 520 315 540 740 890 500 720 920 1100 2.6 4.5 6 7.5 7 11 15 19 10 17 23 30 16 26 36 46 30 50 70 85 55 90 125 155 80 135 185 235 115 185 255 325 180 300 410 520 315 540 740 890 500 720 920 1100 600 600 600 700 700 800 400 800 1100 900 900 1100 1100 640 640 640 770 770 900 460 900 1300 1060 1060 1300 1300 690 690 690 840 840 1000 520 1000 1500 1210 1210 1500 1500 730 730 730 920 920 1100 580 1100 1700 1370 1370 1700 1700 600 600 600 700 700 800 800 900 900 1100 1100 640 640 640 770 770 900 900 1060 1060 1300 1300 690 690 690 840 840 1000 1000 1210 1210 1500 1500 730 730 730 920 920 1100 1100 1370 1370 1700 1700 600 600 600 700 700 800 800 900 900 1100 1100 640 640 640 770 770 900 900 1060 1060 1300 1300 690 690 690 840 840 1000 1000 1210 1210 1500 1500 730 730 730 920 920 1100 1100 1370 1370 1700 1700 600 600 600 700 700 800 800 900 900 1100 1100 640 640 640 770 770 900 900 1060 1060 1300 1300 690 690 690 840 840 1000 1000 1210 1210 1500 1500 730 730 730 920 920 1100 1100 1370 1370 1700 1700 600 600 600 700 700 800 400 800 1100 900 900 1100 1100 640 640 640 770 770 900 460 900 1300 1060 1060 1300 1300 690 690 690 840 840 1000 520 1000 1500 1210 1210 1500 1500 730 730 730 920 920 1100 580 1100 1700 1370 1370 1700 1700 5 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 770 770 770 990 990 1200 640 1200 1900 1520 1520 1900 1900 770 770 770 990 990 1200 1200 1520 1520 1900 1900 770 770 770 990 990 1200 1200 1520 1520 1900 1900 770 770 770 990 990 1200 1200 1520 1520 1900 1900 770 770 770 990 990 1200 640 1200 1900 1520 1520 1900 1900 6 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 810 810 810 1060 1060 1300 700 1300 2100 1780 1780 2100 2100 810 810 810 1060 1060 1300 1300 1780 1780 2100 2100 810 810 810 1060 1060 1300 1300 1780 1780 2100 2100 810 810 810 1060 1060 1300 1300 1780 1780 2100 2100 810 810 810 1060 1060 1300 700 1300 2100 1780 1780 2100 2100 7 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 850 850 850 1140 1140 1400 760 1400 2300 1930 1930 2300 2300 850 850 850 1140 1140 1400 1400 1930 1930 2300 2300 850 850 850 1140 1140 1400 1400 1930 1930 2300 2300 850 850 850 1140 1140 1400 1400 1930 1930 2300 2300 850 850 850 1140 1140 1400 760 1400 2300 1930 1930 2300 2300 High 9 22 35 54 100 180 270 375 600 1000 1250 9 22 35 54 100 180 270 375 600 1000 1250 900 900 900 1200 1200 1500 820 1500 2500 2000 2000 2500 2500 900 900 900 1200 1200 1500 1500 2000 2000 2500 2500 900 900 900 1200 1200 1500 1500 2000 2000 2500 2500 900 900 900 1200 1200 1500 1500 2000 2000 2500 2500 900 900 900 1200 1200 1500 820 1500 2500 2000 2000 2500 2500 ETI Motor Circuit Protector Catalog Number 3-Pole ED63A001 ED63A002 ED63A003 ED63A005 ED63A010 ED63A025 ED63A030 ED63A040 ED63A050 ED63A100 ED63A125 CED63A001n CED63A002n CED63A003n CED63A005n CED63A010n CED63A025n CED63A030n CED63A040n CED63A050 CED63A100 CED63A125 -- -- -- -- -- -- FXD63L150 FXD63A150 FXD63H150 -- -- -- FXD63A250 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- CFD63L150 CFD63A150 CFD63H150 -- -- -- CFD63A250 Thermal Magnetic Catalog Number 2-Pole 3-Pole -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- FXD62B070 FXD62B080 FXD62B090 FXD62B100 FXD62B110 FXD62B125 -- FXD62B150 -- FXD62B175 FXD62B200 FXD62B225 FXD62B250 FXD63B070 FXD63B080 FXD63B090 FXD63B100 FXD63B110 FXD63B125 -- FXD63B150 -- FXD63B175 FXD63B200 FXD63B225 FXD63B250 FD62B070 FD62B080 FD62B090 FD62B100 FD62B110 FD62B125 FD62B150 FD62B175 FD62B200 FD62B225 FD62B250 FD63B070 FD63B080 FD63B090 FD63B100 FD63B110 FD63B125 FD63B150 FD63B175 FD63B200 FD63B225 FD63B250 HFD62B070 HFD62B080 HFD62B090 HFD62B100 HFD62B110 HFD62B125 HFD62B150 HFD62B175 HFD62B200 HFD62B225 HFD62B250 HFD63B070 HFD63B080 HFD63B090 HFD63B100 HFD63B110 HFD63B125 HFD63B150 HFD63B175 HFD63B200 HFD63B225 HFD63B250 -- HHFD63B070 -- HHFD63B080 -- HHFD63B090 -- HHFD63B100 -- HHFD63B110 -- HHFD63B125 -- HHFD63B150 -- HHFD63B175 -- HHFD63B200 -- HHFD63B225 -- HHFD63B250 CFD62B070 CFD62B080 CFD62B090 CFD62B100 CFD62B110 CFD62B125 -- CFD62B150 -- CFD62B175 CFD62B200 CFD62B225 CFD62B250 CFD63B070 CFD63B080 CFD63B090 CFD63B100 CFD63B110 CFD63B125 -- CFD63B150 -- CFD63B175 CFD63B200 CFD63B225 CFD63B250 MOLDED CASE 7 CIRCUIT BREAKERS Note: T olerances for instantaneous trip points meet UL 489 (7.3). Nominal AC instantaneous trip points are given in the tables. For DC instantaneous trip points, add 15% to nominal values. Instantaneous trip adjustment is made through the breaker cover on all frame breakers. To change instantaneous trip point on circuit breaker, depress indicating knob, then rotate to desired position. 7-146 Siemens Industry, Inc. SPEEDFAXTM Product Catalog n Built to order. Allow 23 weeks for delivery. Molded Case Circuit Breakers Adjustable Instantaneous Magnetic Trip Settings Application Breaker Type JXD2(A) JXD6(A) JD6(A) HJD6(A) HHJD6 CJD6 LXD6(A) LD6(A) HLD6(A) HHLD6 CLD6 LMXD6 LMD6 Maximum Continuous Amperes 200 225 250 300 350 400 200 225 250 300 350 400 200 225 250 300 350 400 400 200 225 250 300 350 400 200 225 250 300 350 400 200 225 250 300 350 400 400 450 500 600 250 300 350 400 450 500 600 600 250 300 350 400 450 500 600 250 300 350 400 450 500 600 250 300 350 400 450 500 600 600 500 600 700 800 800 500 600 700 800 Nominal AC Adjustable Trip Range Low 2 3 4 1250 1250 1250 1250 2000 2000 1430 1430 1430 1430 2290 2290 1610 1610 1610 1610 2570 2570 1790 1790 1790 1790 2860 2860 1250 1250 1250 1250 2000 2000 1430 1430 1430 1430 2290 2290 1610 1610 1610 1610 2570 2570 1790 1790 1790 1790 2860 2860 1250 1250 1250 1250 2000 1250 2000 1430 1430 1430 1430 2290 1430 2290 1610 1610 1610 1610 2570 1610 2570 1790 1790 1790 1790 2860 1790 2860 1250 1250 1250 1250 2000 2000 1430 1430 1430 1430 2290 2290 1610 1610 1610 1610 2570 2570 1790 1790 1790 1790 2860 2860 1250 1250 1250 1250 2000 2000 1430 1430 1430 1430 2290 2290 1610 1610 1610 1610 2570 2570 1790 1790 1790 1790 2860 2860 1250 1250 1250 1250 2000 2000 1250 1430 1430 1430 1430 2290 2290 1450 1610 1610 1610 1610 2570 2570 1610 1790 1790 1790 1790 2860 2860 1790 2000 3000 3000 2290 3430 3430 2570 3860 3860 2860 4290 4290 1250 1250 2000 2000 2000 3000 2000 3000 1430 1430 2290 2290 2290 3430 2290 3430 1610 1610 2570 2570 2570 3800 2570 3800 1790 1790 2860 2860 2860 4290 2860 4290 1250 1250 2000 2000 2000 3000 3000 1430 1430 2290 2290 2290 3430 3430 1610 1610 2570 2570 2570 3860 3860 1790 1790 2860 2860 2860 4290 4290 1250 1250 2000 2000 2000 3000 3000 1430 1430 2290 2290 2290 3430 3430 1610 1610 2570 2570 2570 3860 3860 1790 1790 2860 2860 2860 4290 4290 1250 1250 2000 2000 2000 3000 2000 3000 1430 1430 2290 2290 2290 3430 2290 3430 1610 1610 2570 2570 2570 3860 2570 3860 1790 1790 2860 2860 2860 4290 2860 4290 3000 3000 3200 2800 3200 3430 3430 3500 3100 3500 3860 3860 3700 3400 3700 4290 4290 4200 3700 4200 3000 3000 3200 3200 3430 3430 3500 3500 3860 3860 3700 3700 4290 4290 4200 4200 5 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 1960 3140 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 3140 1960 1960 1960 1960 3140 3140 1960 3140 4710 4710 1960 1960 3140 3140 3140 4710 3140 4710 1960 1960 3140 3140 3140 4710 4710 1960 1960 3140 3140 3140 4710 4710 1960 1960 3140 3140 3140 4710 3140 4710 4710 4710 4700 4000 4700 4710 4710 4700 4700 6 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 2140 3430 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 3430 2140 2140 2140 2140 3430 3430 2140 3430 5140 5140 2140 2140 3430 3430 3430 5140 3430 5140 2140 2140 3430 3430 3430 5140 5140 2140 2140 3430 3430 3430 5140 5140 2140 2140 3430 3430 3430 5140 3430 5140 5140 5140 6400 4800 6400 5140 5140 6400 6400 7 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 2320 3710 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 3710 2320 2320 2320 2320 3710 3710 2320 3710 5570 5570 2320 2320 3710 3710 3710 5570 3710 5570 2320 2320 3710 3710 3710 5570 5570 2320 2320 3710 3710 3710 5570 5570 2320 2320 3710 3710 3710 5570 3710 5570 5570 5570 7300 5500 7300 5570 5570 7300 7300 High 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 2500 4000 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 4000 2500 2500 2500 2500 4000 4000 2500 4000 6000 6000 2500 2500 4000 4000 4000 6000 4000 6000 2500 2500 4000 4000 4000 6000 6000 2500 2500 4000 4000 4000 6000 6000 2500 2500 4000 4000 4000 6000 4000 6000 6000 6000 8000 6000 8000 6000 6000 8000 8000 ETI Motor Circuit Protector Catalog Number 3-Pole -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- JXD63L400 JXD63H400 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- CJD63H400 CJD63L400 -- -- -- -- -- -- -- -- -- LXD63L600 LXD63H600 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- CLD63L600 CLD63H600 -- -- -- LMXD63L800 LMXD63A800 -- -- -- -- Thermal Magnetic Catalog Number 2-Pole 3-Pole JXD22B200 JXD22B225 JXD22B250 JXD22B300 JXD22B350 JXD22B400 JXD23B200 JXD23B225 JXD23B250 JXD23B300 JXD23B350 JXD23B400 JXD62B200 JXD62B225 JXD62B250 JXD62B300 JXD62B350 JXD62B400 JXD63B200 JXD63B225 JXD63B250 JXD62B300 JXD23B350 JXD23B400 JD62B200 JD62B225 JD62B250 JD62B300 JD62B350 -- JD62B400 JD63B200 JD63B225 JD63B250 JD63B300 JD63B350 -- JD63B400 HJD62B200 HJD62B225 HJD62B250 HJD62B300 HJD62B350 HJD62H400 HJD63B200 HJD63B225 HJD63H250 HJD63B300 HJD63B350 HJD63B400 HHJD62B200 HHJD62B225 HHJD62B250 HHJD62B300 HHJD62B350 HHJD62B400 HHJD63B200 HHJD63B225 HHJD63B250 HHJD63B300 HHJD63B350 HHJD63B400 -- CJD63B200 -- CJD63B225 -- CJD63B250 -- CJD63B300 -- CJD63B350 -- CJD63B400 -- -- LXD62B450 LXD62B500 LXD62B600 LXD63B450 LXD63B500 LXD63B600 LD62B250 LD62B300 LD62B350 LD62B400 LD62B450 LD62B500 -- LD62B600 LD63B250 LD63B300 LD63B350 LD63B400 LD63B450 LD63B500 -- LD63B600 HLD62B250 HLD62B300 HLD62B350 HLD62B400 HLD62B450 HLD62B500 HLD62B600 HLD63B250 HLD63B300 HLD63B350 HLD63B400 HLD63B450 HLD63B500 HLD63B600 HHLD62B250 HHLD62B300 HHLD62B350 HHLD62B400 HHLD62B450 HHLD62B500 HHLD62B600 HHLD63B250 HHLD63B300 HHLD63B350 HHLD63B400 HHLD63B450 HHLD63B500 HHLD63B600 -- CJD63B250 -- CJD63B300 -- CJD63B350 -- CLD63B400 -- CLD63B450 -- CLD63B500 -- -- -- CLD63B600 -- LMXD62B600 LMXD62B700 -- LMXD62B800 LMXD63B500 LMXD63B600 LMXD63B700 -- LMXD63B800 LMD62B500 LMD62B600 LMD62B700 LMD62B800 LMD63B500 LMD63B600 LMD63B700 LMD63B800 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-147 Molded Case Circuit Breakers Adjustable Instantaneous Magnetic Trip Settings Application Breaker Type HLMXD6 HLMD6 MD6 MXD6 HMD6 HMXD6 CMD6 ND6 NXD6 HND6 HNXD6 CND6 PD6 PXD6 HPD6 HPXD6 CPD6 RD6 RXD6 HRD6 HRXD6 Maximum Continuous Amperes 500 600 700 800 500 600 700 800 500 600 700 800 800 800 500 600 700 800 800 800 500 600 700 800 500 600 700 800 400 500 600 700 800 800 800 800 900 1000 1200 900 1000 1200 800 900 1000 1200 900 1000 1200 800 900 1000 1200 1200 1400 1600 1200 1400 1600 1200 1400 1600 1200 1400 1600 1200 1400 1600 1800 2000 1800 2000 1800 2000 1800 2000 Nominal AC Adjustable Trip Range Low 2 3 4 3000 3000 3200 3200 3430 3430 3500 3500 3860 3860 3700 3700 4290 4290 4200 4200 3000 3000 3200 3200 3430 3430 3500 3500 3860 3860 3700 3700 4290 4290 4200 4200 3000 3000 4000 3000 4000 5000 3430 3430 4570 3430 4570 5715 3860 3860 5140 3860 5140 6430 4290 4290 5710 4280 5710 7145 3000 3000 4000 3000 4000 5000 3430 3430 4570 3430 4570 5715 3860 3860 5140 3860 5140 6430 4280 4280 5710 4280 5710 7145 3000 3000 4000 4000 3430 3430 4570 4570 3860 3860 5140 5140 4280 4280 5710 5710 3000 3000 4000 4000 3430 3430 4570 4570 3860 3860 5140 5140 4280 4280 5710 5710 3000 3000 3000 4000 3000 4000 5000 3430 3430 3430 4570 3430 4570 5715 3860 3860 3860 5140 3860 5140 6430 4280 4280 4280 5710 4280 5710 7145 4000 5000 5000 5000 4570 5715 5715 5715 5140 6430 6430 6430 5710 7145 7145 7145 5000 5000 5000 5715 5715 5715 6430 6430 6430 7145 7145 7145 4000 5000 5000 5000 4570 5715 5715 5715 5140 6430 6430 6430 5710 7145 7145 7145 5000 5000 5000 5715 5715 5715 6430 6430 6430 7145 7145 7145 4000 5000 5000 5000 4570 5715 5715 5715 5140 6430 6430 6430 5710 7145 7145 7145 5000 5000 5000 5715 5715 5715 6430 6430 6430 7145 7145 7145 5000 5000 5000 5715 5715 5715 6430 6430 6430 7145 7145 7145 5000 5000 5000 5715 5715 5715 6430 6430 6430 7145 7145 7145 5000 5000 5000 5715 5715 5715 6430 6430 6430 7145 7145 7145 5000 5000 5000 5715 5715 5715 6430 6430 6430 7145 7145 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5000 5715 6430 7145 5 4710 4710 4700 4700 4710 4710 4700 4700 4710 4710 6280 4710 6280 7860 4710 4710 6280 4710 6280 7860 4710 4710 6280 6280 4710 4710 6280 6280 4710 4710 4710 6280 4710 6280 7860 6280 7860 7860 7860 7860 7860 7860 6280 7860 7860 7860 7860 7860 7860 6280 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 7860 6 5140 5140 6400 6400 5140 5140 6400 6400 5140 5140 6850 5140 6850 8575 5140 5140 6850 5140 6850 8575 5140 5140 6850 6850 5140 5140 6850 6850 5140 5140 5140 6850 5140 6850 8575 6850 8575 8575 8575 8575 8575 8575 6850 8575 8575 8575 8575 8575 8575 6850 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 8575 7 5570 5570 7300 7300 5570 5570 7300 7300 5570 5570 7420 5570 7420 9290 5570 5570 7420 5570 7420 9290 5570 5570 7420 7420 5570 5570 7420 7420 5570 5570 5570 7420 5570 7420 9290 7420 9290 9290 9290 9290 9290 9290 7420 9290 9290 9290 9290 9290 9290 7420 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 9290 High 6000 6000 8000 8000 6000 6000 8000 8000 6000 6000 8000 6000 8000 10000 6000 6000 8000 6000 8000 10000 6000 6000 8000 8000 6000 6000 8000 8000 6000 6000 6000 8000 6000 8000 10000 8000 10000 10000 10000 10000 10000 10000 8000 10000 10000 10000 10000 10000 10000 8000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 ETI Motor Circuit Protector Catalog Number 3-Pole -- -- -- -- -- -- -- -- -- -- -- MXD63L800 MXD63A800 MXD63H800 -- -- -- MXD63L800 MXD63A800 MXD63H800 -- -- -- -- -- -- -- -- -- -- -- -- CMD63L800 CMD63A800 CMD63H800 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Thermal Magnetic Catalog Number 2-Pole 3-Pole -- HLMXD63B500 -- HLMXD63B600 -- HLMXD63B700 -- HLMXD63B800 HLMD62B500 HLMD62B600 HLMD62B700 HLMD62B800 HLMD63B500 HLMD63B600 HLMD63B700 HLMD63B800 MD62B500 MD62B600 MD62B700 -- MD62B800 -- MD63B500 MD63B600 MD63B700 -- MD63B800 -- MXD62B500 MXD62B600 MXD62B700 -- MXD62B800 -- MXD63B500 MXD63B600 MXD63B700 -- MXD63B800 -- HMD62B500 HMD62B500 HMD62B700 HMD62B800 HMD63B500 HMD63B600 HMD63B700 HMD63B800 -- HMXD63B500 -- HMXD63B600 -- HMXD63B700 -- HMXD63B800 -- -- -- CMD63B600 -- CMD63B700 -- -- -- CMD63B800 -- -- ND62B800 ND62B900 ND62B100 ND62B120 ND63B800 ND63B900 ND63B100 ND63B120 NXD62B900 NXD62B100 NXD62B120 NXD63B900 NXD63B100 NXD63B120 HND62B800 HND62B900 HND62B100 HND62B120 HND63B800 HND63B900 HND63B100 HND63B120 -- HNXD63B900 -- HNXD63B100 -- HNXD63B120 -- CND63B800 -- CND63B900 -- CND63B100 -- CND63B120 -- PD63B120 -- PD63B140 -- PD63B160 -- PXD63B120 -- PXD63B140 -- PXD63B160 -- HPD63B120 -- HPD63B140 -- HPD63B160 -- HPXD63B120 -- HPXD63B140 -- HPXD63B160 -- CPD63B120 -- CPD63B140 -- CPD63B160 -- RD63B180 -- RD63B200 -- RXD63B180 -- RXD63B200 -- HRD63B180 -- HRD63B200 -- HRXD63B180 -- HRXD63B200 MOLDED CASE 7 CIRCUIT BREAKERS 7-148 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Molded Case Switch -- Circuit Disconnect Maximum Frame Amp Rating 1100 1125 1250 1400 1600 1800 1200 1600 2000 2-Pole Catalog Number BQ2S060 n BQ2S100n ED22S100An ED42S100An ED42S125An ED62S100An -- CED62S100An CED62S125An -- FXD62S250A HFXD62S250An a JXD22S400An -- -- a -- -- a -- -- a -- a a a 3-Pole Catalog Number BQ3S060n BQ3S100n ED23S100A ED43S100A ED43S125A ED63S100A ED63S125A CED63S100An CED63S125An HQR23S250HA FXD63S250A HFXD63S250An CFD63S250An JXD23S400A JXD63S400A HJXD63S400An CJD63S400An LXD63S600A HLXD63S600An CLD63S600An LMXD63S800An MXD63S800A CMD63S800A NXD63S120A CND63S120An PXD63S160Ae RXD63S200Ane Self-Protective Instantaneous Override ±20%c 11000 11000 11000 11000 11000 11000 11000 11000 11000 12000 13200 13200 13200 16000 16000 16000 16000 16000 16000 16000 18000 18000 18000 10000 10000 10000 10000 Revised on 02/28/19 Selection Ordering Information Order by catalog number. Switches include frame and self protective trip unit only. Order lugs separately from pages 7-156 to 7-158. MOLDED CASE 7 CIRCUIT BREAKERS n Built to order. Allow 23 weeks for delivery. a For 2-pole application use outside poles of 3-pole circuit breaker. b For additional lugs see pages 7-156 to 7-158. Product Category MCCB c Molded case switches up to R frame contain a self protecting instantaneous element, which may open circuit above their override set point. d UL file E57556 Volume 1, section 2 and CSA LR 42022-51. e Requires mounting block MB9301 or MBR9302. Lugs pages 7-156 to 7-158 Enclosures Section 6 Accessories pages 7-163 to 7-168 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-149 Molded Case Circuit Breakers Digital Solid State Sentron Sensitrip IV Series Revised on 05/31/18 Technical The Sentron Sensitrip IV circuit breaker is a true RMS current sensing device. Digital microprocessor circuitry within the electronic trip unit provides more precise control over the circuit breaker functions. This control allows circuit coordination flexibility not available with thermal magnetic circuit breakers. Functions available in Sentron Sensitrip circuit breakers Catalog Number Suffix Trip Type Cont Current Setting Long Time Delay Instan- Short taneous Time Pickup Pickup Short Time Fixed Delay LI LI u u u LIG LIG u u u LSI LSI u u u u u LSIG LSIG u u u u u Short Time I2t Delay u u Ground Fault Pickup Ground Fault Delay u u u u Typical Trip Unit Labeling and Adjustment Positions for the Sentron Sensitrip Circuit Breaker. LI Trip Unitsa LIG Trip Unitsa MOLDED CASE 7 CIRCUIT BREAKERS LSI Trip Unitsa LSIG Trip Unitsa ln = Maximum circuit breaker ampere rating lr = Continuous current rating expressed in amperes Ii = Instantaneous pickup expressed in amperes Isd = Short time pickup expressed in multiples of Ir Ig = Ground fault pickup expressed in amperes tsd = Short time delay - either fixed or I2t time delay function tld = Long time delay - I2t time delay function tg = Ground fault delay - I2t time delay function NOTE: Frame rating (In) of 600A shown as an example. Trip unit settings will vary based on the specific frame rating (In) of the device. a Schematic of advanced trip unit shown. Basic trip units are identical but do not include DAS / Maintenance Mode functionality. 7-150 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Digital Solid State Sentron Sensitrip IV Series (Ir) (tld) (Ii) A. Adjustable "Continuous Amps" Rating Switch All Sensitrip IV solid state molded case circuit breakers have an adjustable ampere rating switch. Adjustments made to this switch change the continuous current rating of the breaker. B. Adjustable "Long Time Delay" Switch All Sensitrip IV circuit breakers have an adjustable long time delay switch to allow for selection of long time delays of fixed time intervals at six times the setting of the adjustable "continuous amps" rating switch. C. Adjustable "Instantaneous Pick-Up" Switch Sensitrip IV circuit breakers with an adjustable instantaneous pick up switch allow selection of a specific instantaneous trip setting. Revised on 05/31/18 Technical (Ir) Time 6 x Ir (tld) Time (Isd) D. Adjustable "Short Time Pick-Up" Switch (Optional) Sensitrip IV circuit breakers with an adjustable short time pick-up switch allow for selection of short time pick-up in a range from 1.5 to 10 times the setting of the maximum current rating. E. Adjustable "Short Time Delay" Switch (Optional) Sensitrip IV circuit breakers with an adjustable short time pick-up switch also contain a switch for adjustment in time delay. The adjustable short time delay switch allows for either of two modes of short time delays. One range of settings enables the breaker to be set for fixed time delays and the other range of settings enables Time the breaker to be set for short time delays based on l2t curves. (tsd) Adjustable "Ground Fault Pick-Up" Switch Sensitrip IV circuit breakers containing the optional equipment ground fault protection have a ground fault pick-up setting. The ground fault pick-up settings allow for one of three time delays based on I2t curves. For 3-phase, 4-wire systems, an external ln = Maximum circuit breaker ampere rating lr = Continuous current rating expressed in amperes Ii = Instantaneous pickup expressed in amperes Isd = Short time pickup expressed in multiples of Ir Ig = Ground fault pickup expressed in amperes (Ig) 3 x Ig (tg) neutral transformer is required with an ampere rating equal to the trip unit ampere rating. tsd = Short time delay - either fixed or I2t time delay function tld = Long time delay - I2t time delay function tg = Ground fault delay - I2t time delay function Examples of Adjustment Settings Catalog Number SLD6A600LI Frame Rating (In) Setting 600A Description 600A max current rating Switch 1 Continuous Current Setting (Ir) 200 200A Swtich 2 Long Time Delay Setting (tld) 2.5 2.5 sec to trip @ 6 x Ir [6 x 200A = 1200A] Switch 3 Instantaneous Pickup Setting (Ii) 750 750A Catalog Number SLD6A600LSIG Frame Rating (In) Setting 600A Description 600A max current rating Switch 1 Cont. Current Setting (Ir) 300 300A Long Time Delay Setting (tld) 10 10 sec @ 6 x Ir [6 x 300A = 1800A] Switch 2 Short Time Pickup Setting (Isd) 1.5 1.5 x Ir [1.5 x 200A = 300A] Instantaneous Pickup Setting (Ii) 5 5 x In [5 x 600A = 3,000A] Swtich 3 Short Time Delay Setting (tsd) 0.1 0.1 sec Switch 4 Ground Fault Pickup Setting (Ig) 36 [.18] Ig = 36 x 10 [36 x 10 = 360A] Ground Fault Delay Setting (tg) 36 [.18] 0.18 sec @ 3 x Ig [3 x 360 = 1,080A] MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-151 WLPower Circuit Breakers 3-pole & 4-pole, up to 6000A Breaker Description The ever-increasing use of plant and energy management systems has intensified the demand for circuit breakers supporting multiple open protocols to monitor and control the flow of energy in the power system. The extensive and modular WL family of circuit breakers and accessories provides this for applications from 200A to 6000A. Applications WL breakers can be applied as main, tie, feeder or distribution breakers in low-voltage electrical power systems. Versions b Frame ratings: 800A to 6000A b 3 physical frame sizes b Rated nominal operating voltage up to 635VAC b Seven interrupting classes from 50kA to 200kA at 480V b Circuit breaker or non-automatic switch b WL Circuit Breakers are delivered as complete assembled breakers or individual frames, guide frames, and accessories Installation Types Fixed-mounted or Draw-out version. Standards b WL ANSI / UL 1066 Circuit Breakers will satisfy: C37.13, C37.16, C37.17, C37.50, NEMA SG3 b WL UL 489 Circuit Breakers will satisfy: UL 489 b WL Circuit Breakers are suitable for use in UL 1558 LV Switchgear and UL 891 LV Switchboards Conditions of Application WL Circuit Breakers are designed to meet standard Industrial and Commercial application requirements. Uniform Dimensions WL Circuit Breaker dimensions differ only in the device width, which varies by frame size. With the exception of the 200kA ANSI Frame Size II which has an additional 5" in depth to accommodate integral fuses and the UL489 Frame Size I which measures only 15" in height to allow six-high stacking in switchboards. Minimal Space Requirements The WL design is extremely compact without sacrificing performance and does not use energy-wasting heat sinks. Trip Units The electronic, micro processor-based trip unit is auxiliary voltage-independent for all protective functions and enables adaptation to the different protection requirements of distribution systems, motors, transformers and generators. Non-Automatic Switch A special version of the circuit breaker is used as a non-automatic switch. The non-automatic switch is constructed without a trip unit and has no protective function. A possible application is for use as a tie in systems with parallel feeds. Main Bus Connectors Breakers are equipped with standard vertical main bus connections. Horizontal bus connections are available as an option in Frame Size 1 and 2 up to 2000A. Communication Capability MODBUS or PROFIBUS communications transmit the acquired and metered data, such as current values, breaker status, trip log, etc. to a central monitoring computer. With a factory installed metering function option, the WL acquires data useful for power management and can contribute to a significant savings in energy costs. A new, internal circuit breaker bus enables the expansion of breaker functionality through the integration of many secondary functions which were previously separate, including: b Control of analog displays b Options for testing the communication setup b Display of breaker status and reason for trip b Input modules for reading other external signals and transmitting these signalsvia PROFIBUS or MODBUS communication b A selection of output modules to provide contact closures based on events or measured-value setpoints. It is not only possible to monitor the breaker remotely, it is also possible to open and close the breaker as well as setting parameters remotely Operating Mechanisms Circuit breakers can be optionally delivered with different operating mechanisms, including: b Manual operating mechanism with mechanical closing (standard) General b Manual operating mechanism with mechanical and electrically interlocked closing b Motorized operating mechanism with mechanical and electrically interlocked closing. Operating mechanisms with electrically interlocked closing are suitable for synchronizing tasks Auxiliary Contacts Auxiliary switches can be added according to the type of installation. They are easily mounted via front, top mounted terminal blocks. Modularity Common guide frames for the draw-out version make them completely interchangeable between the UL 489 and ANSI / UL 1066 rated circuit breakers. Components, such as auxiliary releases, motorized operating mechanisms, trip units, current sensors, auxiliary signal switches, automatic reset devices or interlocks can be used to modify or retrofit any circuit breaker to meet changing requirements. The main contacts can be replaced to extend the life of the circuit breaker and feature integrated contact wear indicators. Electronic Trip Unit Modularity Modularity is the outstanding feature of the new WL Circuit Breakers. The trip units themselves can be retrofitted with special LCDs, ground fault modules, rating plugs and communication modules.100% Rated Circuit Breaker WL circuit breakers are designed for continuous operation at 100% of their current rating without the need for external heat sinks. Conditions of Application WL Circuit Breakers are designed to meet standard Industrial and Commercial application requirements. MOLDED CASE 7 CIRCUIT BREAKERS 7-152 Siemens Industry, Inc. SPEEDFAXTM Product Catalog WL Power Circuit Breakers Communication Information General MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-153 WL Power Circuit Breakers Electronic Trip Units General MOLDED CASE 7 CIRCUIT BREAKERS Trip Unit Functions Basic Protective Functions Long-time overcurrent protection L Short-time delayed overcurrent protection S Instantaneous overcurrent protection I Neutral conductor protection N Ground fault protection G Additional Functions Selectable neutral protection Defeatable short-time protection Defeatable instantaneous protection Selectable thermal memory Zone selective interlocking Selectable I2t or fixed short-time delay Adjustable instantaneous pick-up Selectable I2t or I4t long-time delay Adjustable short-time delay and pick-up Selectable and adjustable neutral protection Dual protective setting capability Dynamic arc-flash sentry Extended instantaneous protection Parameterization and Displays Parameterization by rotary switches (10 steps) Parameterization by communication (absolute values) Parameterization by menu/keypad (absolute values) Remote parameterization of the basic functions Remote parameterization of the additional functions Alphanumeric LCD Graphical LCD Metering Function Metering function Metering function Plus Communication CubicleBUS Communication via PROFIBUS-DP Communication via the MODBUS Communication via the Ethernet (BDA) l Standard -- Not available u Optional ETU745 l l l l u l l l l l l l l l l -- -- l l -- -- -- -- u -- u u l u u u ETU748 l l l l u l -- -- l l l -- l l l -- -- l l l -- -- -- u -- u u l u u u ETU776 l l l l u l l l l l l l l l l l l l -- l l l l -- l u u l u u u 7-154 Siemens Industry, Inc. SPEEDFAXTM Product Catalog WL Power Circuit Breakers 3-pole & 4-pole, up to 6000A Rating Plug It is no longer necessary to replace the current transformer to change the rated current of the breaker. Instead, you simply replace the rating plug which is easily accessible on the front of the trip unit. The circuit breaker is set to the new rated current quickly and is already correctly labeled. Long Time Overcurrent Protection with Switchable I2t/I4t Characteristics The long time overcurrent protection in the ETU745, ETU755 and ETU776 trip units can be switched between an I2t and I4t characteristic to improve coordination between upstream circuit breakers and fuses. Front Panel The front panel is designed so that it can be accessed through a cutout in the door, which means that all controls and displays are accessible even when the cubicle door is closed. The front panels of all Frame Size II and Frame Size III circuit breakers are identical, and allow for two different through-door access designs: Trip unit and front panel controls or front panel controls only. The degree of protection of the front panel is IP 20. Environmental Protection The plastics used are halogen-free and recyclable. Safety and Reliability In order to help protect the electrical distribution system and circuit breaker against unauthorized breaker operations, Exclusive Features Generator/Utility Protection Sets 24/7/365 power availability is critical for some systems. On-site generation capability is growing more and more common in many systems. All of the WL digital electronic trip units allow the system designer to precisely tailor trip settings for the most demanding requirements. However, the 776 trip unit allows one set of trip settings for a fully loaded utility feed and with a simple contact closure, the trip unit toggles to a second trip set tailored to provide optimal generator protection. The wide range of settings allows the WL to provide protection for a minimal generator capacity for only essential loads, through full backup for an entire facility. This dual utility/generator protection capability in a single circuit breaker allows the system designer unparalleled, cost effective, flexibility. Dynamic Arc-Flash Sentry A unique feature of the WL trip unit allows the system designer to achieve lower levels of arc flash energy and delayed tripping for selective trip coordination purposes. a wide range of locking devices can be installed or retrofit, including: b Lockable drawout version to protect against unauthorized removal (standard) b High degree of protection through Plexiglas cover b Mechanical reclosing lockout after long-time, short-time or instantaneous trip (optional) b Devices with trip unit ETU745 or higher are equipped with temperature sensors on the BSS and COM15/COM16 (standard) b Lock provision for locking the breaker in the OPEN position b Lockable covers for the CLOSE button b Lockable racking handle prevents moving the breaker b Lockable charging handle prevents charging the springs Standard Version Features WL Circuit Breakers have the following standard equipment: b Mechanical CLOSE and mechanical OPEN push buttons b Manual operating mechanism with mechanical closing b Contact position indicator b Front panel ready-to-close indicator Dynamic Arc-Flash Sentry (DAS) employs the unique dual protective setting capability of the 776 trip unit, coupled with the ability to easily toggle to a lower arc flash parameter set. A normal operation parameter set can be optimized for selective trip coordination, while the second set is optimized for lower arc flash energy levels. The dynamic action comes from the ability to switch from the normal operation set to the arc flash limiting set based on the presence of personnel as they approach the flash protection boundary. A wide variety of switching methods may be used based on the needs of a particular facility. The capabilities range from fully automatic switching using appropriate occupancy sensors to manual switching via a key operation. Extended Instantaneous Protection Extended Instantaneous protection (EIP), another unique feature of the WL trip unit, allows the system designer to achieve full selective trip coordination up to the short-time rating of the frame while also allowing application of the breaker up to the interrupting rating of the frame. The typical power circuit breaker with an `LS' trip unit, or when General b Spring charge indicator b Rear vertical main contacts b Main contact replacement flag b Auxiliary plug system with bare wire pressure screw terminals. Delivery includes all auxiliary plugs necessary for both factory installed and future field installed accessories b Mechanical trip indicator of the overcurrent release system b Automatic reset after trip b The front panel cannot be removed if the circuit breaker closed b Laminated main contact fingers as part of the breaker contact strip on the drawout circuit breaker b Breaker position display in the operator's panel b Captive crank handle for racking out the breaker b Guide frame with guide rails for easy handling of draw-out version b Breaker cannot be moved in the CLOSED state b Rated current coding between the guide frame and the breaker b Suitable for reverse feed applications b The breaker is always equipped with the required number of secondary disconnect blocks the instantaneous function is switched off on an `LSI' trip unit, can only be applied up to it's short-time rating, commonly 85kA or less. For application on systems with levels of available fault current above the short-time rating, the typical `LS' power circuit breaker cannot be applied or must employ an instantaneous override. This instantaneous override is set at as much as 20% below the short-time rating and can seriously compromise selective trip coordination with downstream breakers. The WL, equipped with EIP, overcomes these limitations by providing full withstand capability, and full coordination, with a minus 0% short-time band tolerance up to 85kA on frame Size II and 100kA on Size III. Above fault currents of 20% higher than the full shorttime rating, the WL breaker is self-protecting, and the EIP function will trip the breaker instantly to protect the frame and the system from these extremely high currents, as high as 150kA on frame Size III. One added benefit is that arc flash energy is greatly reduced in this high current region due to the instantaneous trip response that EIP provides. MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-155 Lug Information Mechanical Lug Revised on 04/30/21 Selection For Use With Type(s) BQ, BQH, BQHF BQE, BQF, BL, BLH, BTd, BTHd, HBL, HBQ Switching Neutrals BG, BLG BQD, CQD BQD6, CQD6 NGG, HGG, LGG Circuit Breaker Ampere Rating Cables Per Lug Lug Wire Range Line Side 1540 1 #14#6 AWG Cu 1 #12#6 AWG Al 45125 1 #8#1 AWG Cu 1 #6#1/0 AWG Al Load Side 1520 1 #14#10 AWG Cu 1 #12#10 AWG Al 2535 1 #14#6 AWG Cu 1 #12#6 AWG Al 4050 1 #8#6 AWG Cu 1 #8#4 AWG Al 5570 1 *exceptions in Table A 1 #8#4 AWG Cu #8#2 AWG Al 80100 1 #4#1/0 AWG Cu 1 #2#1/0 AWG Al 110125 1 #2#1/0 AWG Cu 1 #1/0#2/0 AWG Al Line Side (CQD, CQD6) & Load Side 1540 1 #14#6 AWG Cu #12#6 AWG Al 45100 1 #8#1 AWG Cu #6#1/0 AWG Al 1530 1 #14#6 AWG Cu #12#6 AWG Al 1530 1 #14#6 AWG Cu #12#6 AWG Al 35125 1 #8#1/0 AWG Cu #8#2/0 AWG Al 15125 -- NUT KEEPER PLATE Catalog Number TC1Q1 ab TA1Q1 b Lugs are integral to Circuit Breaker Lugs are integral to Circuit Breaker Lugs are integral to Circuit Breaker Lugs are integral to Circuit Breaker Lugs are integral to Circuit Breaker Lugs are integral to Circuit Breaker Integral Integral TC1Q1 3TC1Q1 (pkg. of 3) 3TC1GG20 (pkg. of 3) TNKG3c (pkg. of 3) Connector wire ranges and cavities are established in conjunction with Table 6.1.4.2.1 of UL 489 standards. Table A For Use With Type(s) BQ, BL, QP Circuit Breaker Ampere Rating Load Side 55-60 Cables Per Lug 1 Lug Wire Range Number of Poles #8#4 AWG Cu-Al #3 AWG requires 22 or 65 kAIC This exception is applicable to 1- and 2-pole only MOLDED CASE 7 CIRCUIT BREAKERS Note: (A) Molded case circuit breakers having a rated ampacity of 125 amperes or less are to be connected with 60 or 75°C wire. Circuit breakers having a rated ampacity greater than 125 amperes shall only be cabled with 75°C cable unless otherwise indicated on the circuit breaker label. Exceptions to this rule are outlined in article 110-14 C(1)(2) of the 2005 National Electrical Code. (B) Connector wire ranges and cavities are established in conjunction with Table 6.1.4.2.1 of UL 489 standards. a Lug is steel. b Sold in package of six. c One nut keeper plate is required with each lug on the NGG breaker. d BT and BTH lug wire range is limited to #14 - #12 AWG for Copper. 7-156 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Lug Information Aluminum Body Lugs for Copper or Aluminum Wire Revised on 05/31/18 Selection For Use With Type(s) QR2, QR2H, HQR2, HQR2H All 2, 3-pole ED2, ED4, ED6, ED6 ETI, HED4, HHED6 Circuit Breaker Ampere Rating 100-250 1525 30100 110125 CED6 All 1-pole ED, HED 3060 70100 FXD6-A, FD6-A, HFD6, cfd6 HHFD6 SJD6-B, SHJD6-B SCJD6-B JXD2(A), JXD6(A), JD6(A), SJD6-B, HJD6(A), HJXD6(A) HHJXD6, HHJD6, SHJD6-B, CJD6, SCJD6-B LXD6(A), LD6(A), SLD6-B, HLD6(A), HLXD6(A), HHLXD6, HHLD6, SHLD6-B, CLD6, SCLD6-B LMD6a, LMXD6a, HLMD6a, HLMXD6a, MD6, MXD6, SMD6-B, HMD6, HMXD6, SHMD6-B, CMD6, SCMD6-B ND6, NXD6, SND6-B, HND6, HNXD6, SHND6-B, CND6, SCND6-B PD6, HPD6, CPD6 PXD6, HPXD6, SPD6-B, SHPD6-B PD6, PXD6, HPD6, HPXD6, SPD6-B, SHPD6-B, RD6, RXD6, HRD6, HRXD6, STD 70250 65-200 200400 250600 500600 500800 8001200 12001600 12002000 Cables Per Lug 1 1 1 1 1 1 1 12 12 12 12 13 12 14 15 16 Lug Wire Range #3300 Kcmil Al/C #14#10 AWG (Cu) #12#10 AWG (Al) #10#1/0 (Cu or Al) #3-3/0 (Cu) #1-2/0 (Al) #104 (Cu or Al) #4#1/0 (Cu or Al) #6 AWG350 kcmil (Cu) #4 AWG350 kcmil (Al) #4 AWG3/0 (Cu or Al) Catalog Number 3TA1QR300 (3 lugs per kit) SA1E025 LN1E100 TA1E6125 LD1E060 (Load Side) LD1E100 (Load Side) TA1FD350A TA2J630 3/0500 kcmil (Cu) 4/0500 kcmil (Al) TA2J6500 3/0500 kcmil (Cu) 4/0500 kcmil (Al) #1500 kcmil (Cu or Al) 1/0500 kcmil (Cu or Al) 500750 kcmil (Cu or Al) 250500 kcmil (Cu or Al) 250500 kcmil (Cu or Al) TA2J6500 TA2K500 TA3K500 TA2N750 b 2TA4P8500 bc 3TA4P8500 bd 2TA4N8500 c 3TA4N8500 d 300600 kcmil (Cu or Al) TA5P600 300600 kcmil (Cu or Al) TA6R600 MOLDED CASE 7 CIRCUIT BREAKERS aUse TA2K500 or TA3K500 only. bUsed for 100% rated MD/ND frame breakers. Rated for 90° C cable. Product Category MCCB cContains 2 connectors plus 1 NDTS end barrier. dContains 3 connectors plus 1 NDTS end barrier. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-157 Lug information Optional Mechanical Lugs Revised on 11/30/19 Selection For Use With Type QR2, QR2H, HQR2, HQR2H ED, HED 1, 2 & 3-pole HFD6, HHFD6, CFD6, F(X)D6-A J(X)D2(A), J(X)D6(A), HJD6(A), HHJD6, SHJD6-B, L(X)D6(A), HHLD6, SCD6-B, HLD6(A), SHLD6-B, CJD6, CLD6, SCJD6-B, SCLD6-B SMD6-B, M(X)D6, HM(X)D6, HMD6, CMD6, SCMD6-B, SND6-B, N(X)D6, HN(X)D6, SHND6-B, CND6, SCND6-B R(X)D6, HR(X)D6 P(X)D6, HP(X)D6, CPD6, SPD6-B, SHPD6-B Circuit Breaker Ampere Rating 100-250 1, 2 & 3-pole 30-125 70250 200600 250600 500600 700800 8001200 16002000 12001600 Cables Per Lug 1 1 1 1 12 Lug Material Cu Cu Cu Cu 1 1 Al Lug Wire Range #3 - 300 Kcmil Cu ONLY) #10#1/0 (Cu) #6 AWG350 kcmil (Cu) 3/0600 kcmil (Cu) 3/0500 kcmil (Cu) 500750 kcmil (Al) 500600 kcmil (Cu) 12 Cu 12 Al 13 Al 15 Cu 14 Al #1 AWG500 kcmil (Cu) 500750 kcmil (Cu) 500750 kcmil (Al) 500750 kcmil (Cu) 500750 kcmil (Al) 300600 kcmil (Cu) 600750 kcmil (Cu/Al) Qty Per Catalog No 3 1 1 1 1 Catalog Number 3TC1QR2520 (3 lugs per kit) TC1ED6150 TC1FD350 TC1J6600a TC2J6500a 1 TA1L6750 1 TC2K500 2 2TA2N8750 3 3TA2N8750 2 2TA3N8750 3 3TA3N8750 1 TC5R600 1 TA4P750s Compression Lugs For Circuit Breaker Types Ampere Rating Lugs (contains indicated number of lugs and necessary hardware per kit) ED2, ED4, ED6, HED4, HHED6, CED6 15125 QR2, QR2H, HQR2, HQR2H 100-250 F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 125250 JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6, SJD6-B, SHJD6-B, SCJD6-B, L(X)D6-A, HL(X)D6-A, CLD6, SLD6-B, SHLD6-B, SCLD6-B 200600 Kits (contain lugs and hardware for complete line or load end of 2 or 3-pole breaker) M(X)D6, HM(X)D6, CMD6, SMD6-B, SHMD6-B, SCMD6-B 500800 N(X)D6, HN(X)D6, CND6, SND6-B, SHND6-B, SCND6-B 9001200 Poles 1, 2, 3 2-3 2, 3 2, 3 2 3 2 3 Lugs Per Kit 1 1 1 1 6 9 8 12 Lug Wire Size Catalog Number #2/0 AWG Cu/Al #6 - 350kcmil Al/Cu 350 kcmil 500 kcmil CCE125 CCQ250 CCF250 CCL600 500 kcmil CCM800K2 CCM800K3 CCN1200K2 CCN1200K3 Distribution Lugs For Circuit Breaker Types NGG, HGG, LGG Ampere Rating 15-125 Poles 1,2,3 ED2, ED4, ED6, HED4, HHED6, CED6 15-125 1,2,3 F(X)D6-A, HF(X)D6, HHF(X)D6, CFD6 70-250 2,3 JXD2-A, J(X)D6-A, HJ(X)D6-A, HHJ(X)D6-A, CJD6-A, SJD6-B, SHJD6-B, SCJD6-B, L(X)D6-A, HL(X)D6-A, CLD6-A, 200-600 2,3 SLD6-B, SHLD6-B, SCLD6-B Lugs Per kit 1 1 1 1 Wires Per Lug 6 6 6 6 Lug Wire Size #6-#4 AL #14-#4 Cu #14-#4 AWG Cu #6-#4 AWG Al #14-#4 AWG Cu #6-#4 AWG Al #14-2/0 AWG Cu #6-2/0 AWG Al Catalog Number TA6GG04 TA6ED06 TA6FD04 TA6JD20 MOLDED CASE 7 CIRCUIT BREAKERS s Built to order. Allow 68 weeks for delivery. aUsed for 100% rated JD/LD frame circuit breakers. Special purpose wire connectors, not for general use. 7-158 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Molded Case Circuit Breakers Revised on 10/31/18 Modifications General/Selection A variety of internal and external accessories, as well as modifications, are available to adapt Siemens circuit breakers to special installation requirements. UL listed internal accessories for 100 through 2000A circuit breakers are field-addable. Internal accessories fine tune an electrical distribution system, allowing control of the circuit breakers to meet special application requirements. For example, emergency situations may dictate tripping critically placed circuit breakers quickly. Shunt trips accomplish this conveniently and efficiently. Or, when voltage drops are a concern, undervoltage trips automatically open the circuit breaker at a predetermined voltage level. A wide range of external operating and mounting accessories is also available. For example, face, shallow, and back mounting plates are ideal for tailoring BQ circuit breakers to OEM applications. A complete line of operating handles and handle-blocking devices meet switchboard, enclosure and safety needs. Plug-in mounting assemblies, which simplify switchboard mounting of circuit breakers and permit breaker removal without disconnecting bus or cable connections, are available. 50°C Ambient Calibration -- Not UL listed and not available for solid state, 100% rated breakers or 400HZ calibrated breakers. F or BL Type Circuit Breakers -- Add suffix `M' to catalog number (Example: B120M)....................................................................................No Charge For BQ and ED Frame Circuit Breakers -- Replace `B' in catalog number with `M'.................................................No Charge (Example: BQ3M060, ED63M060) For FD, JD, LD, LMD, MD, ND, PD, and RD Frame Circuit Breakers Non-Interchangeable Trip (3pole only).................................................No Charge -- Replace `B' in catalog number with `M' (Example: FXD63M225, JXD63M400) 400 HZ Calibration ULListed (5KA IR) for BQ & BL Type Circuit Breakers (200A max.)............................................Add 25% to list price -- Add suffix `Y' to catalog number Not ULListed for all other Circuit Breakers, see derating tables on page 7-170 and order standard circuit breakers. Fungus Proofing All BQD, CQD, GB, GG, ED, FD, JD, LD, LMD, MD, ND, PD, RD, DG, FG, JG, LG, MG, NG, and PG Frame Circuit Breakers are inherently fungus resistant and do not require special treatment. For BL, and BQ Type Circuit Breakers............................................................Add $10.00 net per pole -- Consult Sales Office for Availability For all other Circuit Breaker Types..................................................................Add $160.00 net per device -- Consult Sales Office for Availability Certificate of Compliance with Test Report (catalog number CERT OF COMP.) Add $210.00 net Certificate of compliance testing must be performed on the actual device being shipped. The certificate cannot be provided after initial shipment. Order for devices with COC requirement must be placed directly with the factory by the sales office and shipped directly to the end user. UL 489 Supplement SB Naval Use Breakers Breakers tested to UL 489 Supplement SB are qualified for use on non combat and auxiliary naval vessels. Various Siemens molded case breakers can be labeled "NAVAL" in compliance with UL 489 Supplement SB. See table to the right for specific breaker types and UL file references. Supplement SB testing comprises two sets of vibration tests. The first is to find mechanical resonances in the product and to subject the breaker to extreme testing at each resonant frequency. The second is a swept frequency test, in which the frequency of excitation is changed in intervals of 1Hz, and held at each frequency for five minutes. The excitation frequencies run from 4 to 33Hz, and the test is conducted in each of the three orthogonal axes of the breaker. During these tests, the breaker must not trip from the closed position, nor may the contacts touch from the open position. Calibration and insulation resistance are also verified during the test. For detailed information, refer to UL 489, Supplement SB. Ordering Information For "NAVAL" label, add $75. net per catalog number per order. Order must be placed directly with the factory by Siemens Sales Office. Breaker Type BL NGB CED6 HED4, ED6 FXD6, HFD6, HHFD6 HHJD6 UL File E82615, Vol 1, Sec 1 & 4 E10848, Vol 10, Sec 3 E10848, Vol 4, Sec 13 E10848, Vol 4, Sec 11 E10848, Vol 4, Sec 17 E10848, Vol 4, Sec 20 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-159 Molded Case Circuit Breakers Revised on 06/30/19 Internal Accessories General Feature Combinations The available feature combinations are shown in the chart below. For applications requiring combinations of features not listed in this chart, consult the sales office for availability. Breakers QP, BQ, BLa BQD, CQD, GB, GG QR All ED All FD All JD, LD, LMDb SJD, SHJD, SCJD,SLD, SHLD, SCLDc All MD, ND, PD, RD Including Electronic tripd Modules Avail. On ST/ Per Breaker ST/ ST/ AUX/ Breaker Poles ST AUX ALSW ALSW 1 1, 2, 3 1 -- -- -- 1 2, 3 1 1/1 -- -- 1, 2 2, 3 1 1/1 -- -- 1 1, 2, 3 1 1/1,1/2 1/1 1/1/1 2 2, 3 1-- -- -- 2 2, 3 1 1 -- -- UVT/ UVT AUX -- -- -- -- -- -- 1 1/1, 1/2 1 1/1 1 1/1, 1/2 UVT/ ALSW 1/1 -- -- UVT/ AUX/ ALSW 1/1/1 -- -- AUX 1,2 1,2 2 1, 2 1, 2 1, 2 1 3 1 1 -- -- 1 1/1, 1/2 -- -- 1, 2 2 2, 3 1 1/1 -- -- 1 1/1, 1/2 -- -- 1, 2 AUX/ ALSW -- 1/1 -- 1/1, 2/1 1/1 1/1, 1/2 Elect. Bell Ground Grd fault ALSW Alarm fault w/Bell -- -- -- -- 1 -- -- -- -- -- -- -- 1 -- 1 1 1 -- -- -- 1, 2 -- -- -- 1/1, 1/2 1, 2 -- -- -- 1/1, 2/1 1, 2 -- -- -- Shunt Trip (ST) One or all critical circuit breakers may be tripped from a distant control point by use of a shunt trip device. A shunt trip operates through an auxiliary switch contact; when the breaker opens, current is not maintained on the shunt trip coil. Undervoltage Trip (UVT) When voltage drops to a value below 35% of the nominal coil rating, the undervoltage trip device automatically opens the breaker. The operation is instantaneous, and the circuit breaker cannot be reclosed until the voltage returns to 85% of line voltage. The undervoltage trip, which is continuously energized, must be energized before the circuit breaker can be closed. Auxiliary Switch (AUX) For applications requiring remote "on" or "off" indication (or electrical interlocking), auxiliary switches are available. Each switch comprises an "A" (open when circuit breaker is open) and a "B" (closed when circuit breaker is open) contact with a common connection. (Form C) Alarm Switch (ALSW) The alarm switch contact is closed when the circuit breaker is opened automatically by an overload, short circuit, shunt trip or undervoltage trip. The alarm switch contact is open when the circuit breaker is reset. MOLDED CASE 7 CIRCUIT BREAKERS For ED Frames S01FD60 For FD Frames S01FD60 For JD and LD Frames aFactory assembled only bIf mechanical interlock is installed, no accessory module can be installed in the right pocket. cIf mechanical interlock is installed, no accessory module can be installed. dIf mechanical interlock is installed, no accessory module can be installed in the left pocket. 7-160 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Circuit Breakers Revised on 04/30/21 Circuit Breaker Accessories Circuit Breaker Accessories Catalog Number For Use With Breaker Type Number of Poles Standard Package Padlocking Device For locking breaker in "OFF" position. Note "ON" position does not affect breaker fuctionally ECPLD1 Type QP, BL, QAF2, QPF2, QE, QT-Duplex, BQ, BQXD, 1P BT-Duplex, BTH-Duplex ECPLD1R Type QP, BL, QAF2, QPF, QE, QT-Duplex, BQ, BQXD, 1P BT-Duplex, BTH-Duplex (Red Color) ECPLD2 Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, 2P BQXD ECPLD2R Type QP, BL, QAF2, QPF, QE, QT-Triplex & Quadplex, BQ, 2P BQXD (Red Color) ECPLD3 Type QP, BL, QAF2, QPF, QE, BQ 3P US2:ECPLD3R Type QP, BL, QAF2, QPF, QE, BQ (Red Color) 3P ECQLD3 Type QP, BL, BQ, BQXD 1P ECQLD4 Type QT-Duplex QT-Duplex Breakers ECQLN3 150-225 MBKA, QN, QNR n/a ECQTH4 Type QP, BL, BQH Designed for (3) 1P Breakers 3 Pieces 3 Pieces 3 Pieces 3 Pieces 1 Piece 1 Piece 10 Pieces 10 Pieces 1 Piece 1 Piece Handle Tie Provide simultaneous swiching of 2 adjacent handles. ECQTH2 Type QT Duplex, BT-Duplex, BTH-Duplex ECQTH3 Type QP, BL Designed for (2) QT Duplex Breakers 2P 25 Pieces 50 Pieces Mechanical Interlock ECQML12 Type QP, BL, BQ Interlock Bracket Designed for 1" Breaker 10 Pieces Handle Blocking Device For holding breaker in "ON" or "OFF" position. Not a lockout/tagout device ECBX231M Type QT, BT-Duplex, BTH-Duplex 1/2" Breakers ECQLD4 Type QT, BT-Duplex, BTH-Duplex 1/2" Breakers ECQL1 Type QP, BQ, BL, BQXD 1P 10 Pieces 10 Pieces 10 Pieces Main Breaker Retainer ECMBR1 ECMBR2 EQ Load Centers Ultimate Load Centers 1 Piece 1 Piece Mounting Accessories MB120 FP9508 FP9555 FP9556 SMB6R TCH65K BR2 BR3 BR4 I0204ML1125CU I0303ML3100CU Type BQ, BQH Mounting Clips Type BQ, BQH FACE MOUNT PLATE Type BQ, BQH FACE MOUNT PLATE Type BQ, BQH FACE MOUNT PLATE Type BQ MOUNTING BRACKET Type BQ MOUNTING ADAPTER Type BQ, BQH, BQXD Back Mounting Plates Type BQ, BQH, BQXD Back Mounting Plates Type BQ, BQH, BQXD Back Mounting Plates Type QP Back Mounting Plates Type QP Back Mounting Plates 1P 1P 2P 3P 1P, 2P, 3P 2P 3P 4P 1P, 2P 3P 20 Pieces 10 Pieces 10 Pieces 10 Pieces 6 Pieces 500 Pieces 10 Pieces 10 Pieces 10 Pieces 10 Pieces 10 Pieces Replacement Lugs TA1Q1 Type BQ, NGG 100A Al Cu LGS n/a TC1Q1 Type BQ, NGG 40A Al Cu LUGS n/a 6 Pieces 6 Pieces Finger Shield BQFS1K Type BQXD Finger Shield (Bulk Pack) n/a BQFS2 Type BQXD Finger Shield n/a 1000 Pieces 2 Pieces Filler Plate ECQF3 1" Filler Plate n/a 5 Pieces MOLDED CASE 7 CIRCUIT BREAKERS For a complete list of standby power mechanical interlock kits, see page 1-25 For use with Ultimate Load Center Main Breakers Not suitable for use on 15-50A, 10 AIC Type QP Circuit Breakers QP Type includes QPH, HQP BL Type includes BLH, HBL BQ Type includes BQH, HBQ QAF2 Type includes QAFH2, BAF2, BAFH2, QFGA2, QFGAH2, BFGA2, BFGAH2 QPF Type includes QPHF, BLF, BLHF QE Type includes QEH, BLE, BLEH Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-161 Circuit Breakers Circuit Breaker Accessories Padlocking Device ECPLD1 General ECQLD3 ECPLD2 Handle Tie ECPLD1R/2R/3R (Single pole pictured. 2-/3-pole available) ECQLD4 Handle Blocking Device ECQL1 ECQTH4 ECQTH2 Main Breaker Retainer ECQTH3 ECBX231M Mechanical Interlock MOLDED CASE 7 CIRCUIT BREAKERS ECMBR1 Mounting Accessories ECMBR2 ECQML12 FP9508 MB120 SMB6R I0204ML1125 7-162 Siemens Industry, Inc. SPEEDFAXTM Product Catalog FP9555 FP9556 Molded Case Circuit Breakers External Accessories Handle Ties with Padlock Device Provide simultaneous switching of 2 or 3 adjacent handles. Do not provide common trip. For Use With Breaker Frame(s) BQD, NGB, HGB, LGB Catalog Number BQDHT2 BQDHT3 Standard Package 10 10 Wt Lb/ Std Pkg 1/2 1/2 Padlocking Devices For locking breaker in "OFF" position. All QR HPLQR 1 1/4 All BQD, CQD, NGB, HGB, LGB BQDPLD 01 1/8 NGG, HGG, LGG HPLG 01 1/4 All ED ED2HPL 01 1/4 All FD FD6PL1 01 1/4 All JD, LD, LMD JD6HPL 01 1/4 All MD, ND, PD, RD MN6PLD 01 1/4 Handle Blocking Devices For holding breaker in "ON" or "OFF" position. Not a lockout/tagout device. All QR All BQD, CQD, GG, GB All ED All FD All JD, LD, LMD All MD, ND, PD, RD HBLQR 1 1 BQDHBD 01 1/4 E2HBL 01 1/4 FD6HB1 01 1/2 JD6HBL 01 1/2 MN6BL 01 1/2 Handle Extensions For replacement. One extension shipped with breaker. All MD, ND, PD, RD EX11 01 2 Terminal Shields Breaker Type HGG, LGG, NGG JD, LD MD, ND, PD, RD Poles 3 3 3 Catalog Number TSSG3A JDTERMSHIELD MDTERMSHIELD Standard Package 1 1 1 Revised on 02/28/19 Selection FD Padlocking Device FD6PLI FD Handle Blocking Device FD6HB1 Handle Extension EX11 MOLDED CASE 7 CIRCUIT BREAKERS n Built to order. Allow 23 weeks for delivery. a Sold only in standard package quantities. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-163 Molded Case Circuit Breakers Revised on 12/31/21 External Accessories Face Mounting Plates For Use With Breaker Frame(s) CQD, CQD6 NGG, HGG, LGG Number of Poles 1 2 3 1 2 3 Catalog Number CQDFMB1 CQDFMB2n CQDFMB3n FMPG1 FMPG2 FMPG3 Standard Package 1 1 1 1 1 1 Wt Lb/ Std Pkg 1/4 1/4 1/4 1/4 1/4 1/4 Selection Back Mounting Plates ED2, ED4, ED6, HED4, HED6 1 E2BMB Mounting Screw Kits CQD, CQD6 NGG, HGG, LGG All QR All ED (CED6 requires 2 kits) All FD (CFD6 requires 2 kits) All JD, LD All LMD All MD, ND, All PD, RD CQDSMK a MSKG4a MSQR3 MSE6a MSE6100b MSF6a MSF650c MSJ6a MSLMD MSMN MSPR6 "MI" Mechanical Interlocks For Use With Breaker Type(s) Panel g Mounted All QR (Sliding Bar) SBMIQR All FD All JD, LD All LMD All MD All ND All PD, RD MI5444 MI5413 d MI5406 dn MI5404 en MI5404 en MI5405es Plug-in Mounted -- MI5444 -- -- -- -- -- 1 1/4 1 11/4 1 1/4 1 1/5 1 1/4 100f 1 1 1/4 50f 1 1 1/4 1 1/4 1 1/4 1 2 Standard Package 1 1 1 1 1 1 -- Wt Lb Std Pkg 11/2 -- 1 1 3 3 -- Mounting Screw Kit MSE6 Mechanical Interlock MI5444 MOLDED CASE 7 CIRCUIT BREAKERS Service Entrance Barriers For Use With Breaker Frames All Enclosed QR Frame Breakers All Enclosed ED Frame Breakers All Enclosed FD Frame Breakers All Enclosed JD & LD Frame Breakers All Enclosed LMD Frame Breakers All Enclosed MD & ND Frame Breakers All Enclosed PD & RD Frame Breakers Description Service entrance barrier QR 3-Pole only Line or load side Service Entrance Barrier Kit for 3-pole only 15A-100A ED Line side only 15-125A CED6 Line or load side Service Entrance Barrier Kit for 2- or 3-pole Line or Load side Service Entrance Barrier Kit for 2- or 3-pole Line or Load side Service Entrance Barrier Kit for 2- or 3-pole Line or Load side Service Entrance Barrier Kit for 2- or 3-pole breakers with oversize lugs and NDTS shield Line or load side Service Entrance Barrier Kit for 2- or 3-pole Line or Load side Catalog Number ECLTB4 SEBENED63 SEBENFD63 SEBENJD63 SEBENLMD63 SEBENMND63EXT SEBENPRD63 n Built to order. Allow 23 weeks for delivery. s Built to order. Allow 68 weeks for delivery. aKit consists of 4 screws and washers. bConsists of 1 screw and washers (order 100). cConsists of 1 screw and washers (order 50). d With mechanical interlock in place, no accessory can be installed into circuit breaker right pole. e Addition of the mechanical interlock will prevent accessory installation in the left pole. f Sold only in standard package quantities. Multiply List Price Each times package quantity for full price. 7-164 Siemens Industry, Inc. SPEEDFAXTM Product Catalog g Mechanical interlock is not designed for use within Siemens panelboards. Product Category MCCB Molded Case Circuit Breakers External Accessories Rotary Door Mounted Operating Handles Types 1, 3, 3R , 12, 4 4X For Use With Breaker Frames EDa FD JD, LD LMD Complete Mechanism Catalog Number Standard Depth Variable Depth CRHOESD CRHOEVD CRHOFSD CRHOFVD CRHOJSD CRHOJVD CRHOLMSD CRHOLMVD Breaker Handle Only Operator Catalog Number CRHOHc Catalog Number RHOEBO RHOFBO RHOJBO RHOLMBO MD, ND PD, RD RHONSD RHONVD RHOHc RHONBOd Shaft Only Length (inches) 2 12 16 Catalog Number RHOSSD RHOSVD RHOSXD 3 RHONSSDs 12 RHONSVD 24 RHONSXD Rotary Door Mounted Operating Handles Types 1 & 12 For Use With Breaker Frames CQD, NGG, HGG, LGG Standard Depth Catalog Number -- Variable Depth Catalog Number RHOCQVD Handle and Shaft Catalog Number RHOH62e Breaker Operator Catalog Number CQDOP ED D11CEU1 D11CEU2 -- -- FD D11CFU1s D11CFU2 -- -- JD, LD -- D11CJU2 -- -- For CQD, NGG, HGG and LGG red emergency handle, order assembly RHOCQVDE (includes handle and operator).s For CQD, NGG, HGG and LGG in a NEMA 3R enclosure, order CQDOP34 operator, RHOH handle and RHOSVD shaft. For CQD, NGG, HGG and LGG in a NEMA 4 or 4X enclosure, order CQDOP34 operator, RHOH4 handle and RHOSVD shaft. Through Door Mounted Operating Handlesb Types 1 & 12 For Use With Breaker Frames Standard Depth Catalog Number Variable Depth Catalog Number CQD, NGG, HGG, LGG ED FD FMHOS E2RH1 F6RH1 -- E2RHV9 F6RHV9 Door Latch Kits Type 2 point latch 3 point latch Catalog Number Right Hand DKR2 DKR3 Catalog Number Left Hand DKL2n DKL3n Revised on 02/28/19 Selection RHOH CRHOH D11CEU2 Standard Depth F6RH1 MOLDED CASE 7 CIRCUIT BREAKERS Rotary Handle RHOCQVD n Built to order. Allow 23 weeks for delivery. s Built to order. Allow 68 weeks for delivery. a For use on 3-pole ED frame only. Product Category MCCB Variable Depth F6RHV9 b M eets the requirements of NFPA 79, section 5.3.3.1 for locking external operator disconnecting devices. c For 3 or 3R, order shaft and breaker operator as shown, and handle RHOH. For 4 & 4X, order handle RHOH4. Consult sales office for additional EG operator shaft lengths. d For extended shaft support order catalog number RHONSB2. e Length of shaft is 300mm (11.8 inches). Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-165 Molded Case Circuit Breakers External Accessories Max-FlexTM, Flange Mounted Variable Depth Operatorsc Frames GG ED FD JD, LD, SJD, SLD LMD MD, ND, PD, RD, SMD, SND, SPD NEMA Type 1, 3 (R), 12 4 (x) 1, 3 (R), 12 4 (x) 1, 3 (R), 12 4 (x) 1, 3 (R), 12 4 (x) 1, 3 (R), 12 4 (x) 1, 3 (R), 12 4 (x) Complete Kit Catalog Number MFKG3R3 MFKG4X3 FHOE036a -- FHOF036 -- FHOJ036 -- FHOLM036 -- FHON048 -- Handle Only Catalog Number MFHG3R MFHG4X FHOH FHOH4 FHOH FHOH4 FHOH FHOH4 FHOH FHOH4 FHOHN FHOHN4 Breaker Operator 36" Cable Catalog Number Catalog Number MFMG MFCF036 FHOEBOa FHOEC036 FHOFBO FHOFC036 FHOJBO FHOJC036 FHOLMBO FHOJC036 FHONBO FHONC048b Max-FlexTM handles are available with solid black handles instead of the customary "red for on" flange handle. These are preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the letter "i" to the catalog number (e.g. FHOHI). Alternate Length Cable Only ED FD Inches Catalog Number 048 FHOEC048 060 FHOEC060 072 FHOEC072 96 FHOEC096 120 FHOEC120s 144 FHOEC144s Catalog Number FHOFC048 FHOFC060 FHOFC072 FHOFC096 FHOFC120 FHOFC144s JD/LD/LMD Catalog Number FHOJC048 FHOJC060 FHOJC072 FHOJC096 FHOJC120s FHOJC144s MD/ND/PD/RD Catalog Number FHONC048 FHONC060 FHONC072 FHONC096 FHONC120s FHONC144s Handle Auxiliary Switch For use with Max-Flex and Rotary Door operators (FHOH and RHOH). 1 NO and 1 NC contact (Form C). For Use With ED, FD, JD, LD, LMD, ND, PD, RD, SD, Max Flex Catalog Number HAS1 Fixed Depth Flange Mounting Frames ED FD Minimum Enclosure Depth 6.44 6.44 NEMA Type 1, 3R, 12 4, 4X 1, 3R, 12 4, 4X Left Hand Mount Catalog Number FDFBELs FDFBEL4s FDFBFLs FDFBFL4s Right Hand Mount Catalog Number FDFBERs FDFBER4s FDFBFRs FDFBFR4s Max-FlexTM handles are available with solid black handles instead of the customary "Red for On" flange handle. These are preferred for use in IECmarkets, where red handles have specific meaning. Order components separately, appending the letter "i" to the catalog number (e.g. FHOHI). Revised on 02/28/19 Selection FHOH FHOFBO FHOFC036 FDFBFR MOLDED CASE 7 CIRCUIT BREAKERS s Built to order. Allow 68 weeks for delivery. aFor 1- or 2-pole breaker order FHOED036 complete kit or FHOEDBO breaker operator only. Use MFHM3R handle. b4 8 inch cable is standard length for M through R frame Max-Flex operators. cM eets requirements of NFPA 79, section 5.3.3.1 for locking external operator disconnecting devices 7-166 Siemens Industry, Inc. SPEEDFAXTM Product Catalog dConsult sales office for additional cable lengths for EG Flex Shaft Operators. For 3-Pole only. 3-Pole ED only. Product Category MCCB Molded Case Circuit Breakers External Accessories Telemand® Motor Operator Breaker Frame AC Voltage ED except CED 120 240 ED motor operator opens downward. Hinged to Open Down Catalog Number MOE6120 MOE6240 s Breaker Frame FD JD, LD LMD MD, ND, PD, RD DC Voltage 24 48 125 24 48 125 24 48 125 -- -- Hinged to Open Right Catalog Number MOF6024DCs MOF6048DCs MOF6125DCs MOJ6024DCs MOJ6048DCs MOJ6125DCs MOLMD6024DCs MOLMD6048DCs MOLMD6125DCs -- -- AC Voltage 120 240 120 240 120 240 120 240 Hinged to Open Right Catalog Number MOF6120 MOF6240 MOJ6120 MOJ6240 MOLMD6120 MOLMD6240 EMOPL120MN EMOPL240MN To order FD through RD motor operators with Left side hinges, add "L" to catalog number (e.g. MOF6120L). List prices are the same.s Dimensions Frame ED FD JD, LD, LMD MD, ND, PD, RD A 7.04 9.50 11.00 16.00 B C 4.31 -- 4.55 1.60 7.50 0.79 9.00 -- D E 4.31 13.84 6.84 9.70 8.34 9.85 9.83 13.13 F 8.84 7.58 7.74 10.13 Operating Currents Catalog Number MOE6120 MOE6240 MOF6120/L MOF6240/L MOLMD6120/L MOJ6120/L MOJ6240/L EMOPL120MN EMOPL240MN On In-Rush (Amps) 10.25 5.2 13.6 7.6 13.6 13.6 7.6 15 7.6 Running (Amps) 2.3 1.1 5.5 3.5 6 6 3.5 5.5 3.25 Time (msec) 550 500 200 200 210 210 217 500 500 Off In-Rush (Amps) 10 5 13.6 7.6 13.6 13.6 7.6 15 7.6 Running (Amps) 2.3 1 5.5 3.5 6 6 3.5 5.5 3.25 Time (msec) 400 330 175 185 185 185 185 500 500 Reset (Amps) 2.3 1.1 5.5 3.5 6 6 3.5 5.5 3.25 Selection/Dimensions Telemand Motor Operator FD, JD, LD, LMD, MD, ND, PD, RD Frames Front View MOLDED CASE 7 CIRCUIT BREAKERS For inches / millimeters conversion, see Application Data section. s Built to order. Allow 68 weeks for delivery. Product Category MCCB Bottom View Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-167 Molded Case Circuit Breakers External Accessories Plug-In Mounting Assemblies, Including Base and Tulip Assemblies For Use With Breaker Frames All ED except CED CED All FD except CFD CFD All JD except CJD All LD except CLD All MD All ND Poles 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 Line Side Catalog Numberb PC2637s PC2657 PC2637s PC2657 PC4753s PC4754 PC4753s PC4754 PC5777s PC5778 PC5660s PC5661 PC5662s PC5663 PC5664cs PC5666 c Load Side Catalog Numberb PC2638s PC2658 PC2638s PC2658 PC4753s PC4754 PC4753s PC4754 PC5777s PC5778 PC5660s PC5661 PC5662s PC5663 PC5664cs PC5666 c Steel Switchboard Mounting Plate a Catalog Number PL2616 PL2617 PL4762 PL4763 PL5796 PL5680 PL9698 PL9699 Tulip Assemblies Separately For Frame ED FD JD LD MD ND 3-Pole Catalog Number TCE3s TCF3s TCJ3s TCL3s TCM3s TCN3s Rear-Connecting Studs For Use With Breaker Frames Ampere Rating Description All ED All FD All JD All LD CJD, SCJD CLD, SCLD LM(X)D6, HLM(X)D6 All MD, ND 100 Line Side (Short) 100 Load Side (Short) 100 Line Side (Long) 100 Load Side (Long) 250 Short 250 Long 400 Short 400 Long 600 Short 600 Long Add required shield kit. 800 1200 1200 Short Long Short Long Extension Behind Breaker (inches) 2.38 2.38 4.88 4.88 3.12 7.06 5.85 11.20 5.85 11.20 5.85 11.20 5.50 8.00 Line Side Catalog Numberd RS2643es -- RS2641es -- RS4756es RS4755es RS5774s RS5773s RS5784s RS5783s RS5788s RS5787s RS5786s RS5785s Load Side Catalog Number d -- RS2644es -- RS2642es RS4756es RS4755es RS5774s RS5773s RS5784s RS5783s CLRSJL3 RS5788s RS5787s RS5786s RS5785s Revised on 06/30/21 Selection Base Switchboard Mounting Plate Tulip Assemblies RS4755 RS4756 Circuit Breaker With Rear-Connecting Studs MOLDED CASE 7 CIRCUIT BREAKERS s Built to order. Allow 68 weeks for delivery. aMust be ordered separately with other plug-in assemblies. bEach piece catalog number consists of (1) mounting block assembly and required tulip assemblies (2) for 2-pole, (3) for 3-pole cFor vertical bus mounting -- for horizontal, substitute PC5665 for PC5664 and PC5667 for PC5666. dPrice includes one current stud, insulating tube, stud nuts and terminal shields, when required. 7-168 Siemens Industry, Inc. SPEEDFAXTM Product Catalog eFor proper electrical clearance, studs must alternate between short and long stud lengths on circuit breaker poles (e.g. SLSLSL or LSLSLS). fPlug-in assembly for EG breakers include line and load side in one assembly. Product Category MCCB Molded Case Circuit Breakers Revised on 05/31/18 Unusual Operating Conditions Reference Note: The information provided on this and the next page is intended for reference and recommendation only. Because several variables can act on a circuit breaker's performance at the same time, the data below is based less on controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. High Ambient Temperatures Because thermal-magnetic trip breakers are temperature sensitive and calibrated for a specific ambient of 40° C (104° F) (average enclosure temperature), a higher ambient will cause the breaker to trip at lower current than its nameplate rating, in other words, causing the breaker to "derate" (see Table 1). Similarly, the current carrying capacity of a circuit conductor is based upon a certain ambient temperature, a higher ambient will reduce its current carrying capacity, causing it to "derate." Thus, with a fluctuating temperature, a thermal-magnetic breaker will derate nearly parallel with its connected circuit conductors and maintain close circuit protection. If the application temperature exceeds 40° C (104° F) and is known, either a breaker specially calibrated for the higher ambient or one oversized according to Table 1 may be selected. In a case such as this, the circuit conductors should be oversized as well. Siemens Sensitrip® IV and Type SB Encased Systems Breakers are insensitive to temperature changes. However, they do include circuitry to protect the components from abnormally high temperatures. Moisture -- Corrosion For atmospheres having high moisture content and / or where fungus growth is prevalent, a special preventive treatment may be required. Where the air is heavily laden with corrosive elements, breakers made with special corrosion-resistant finishes may be required. Altitude Reduced air density at altitudes greater than 6600 ft. (2000 meters) affects the ability of a molded case circuit breaker to transfer heat and interrupt faults. Therefore, circuit breakers applied at these altitudes should have interrupting, insulation and continuous currents derated as indicated in Figure 1. Table 1 -- Temperature Derating Data for Thermal-Magnetic Breakers Reference Ampere Rating at 40°C (104°F) 15 20 25 30 35 40 50 60 70 90 100 125 150 175 200 225 250 300 350 400 500 600 700 800 900 1000 1200 1400 1600 1800 2000 Ampere Rating at: 50°C (122°F) 13 18 23 28 30 37 46 56 65 84 94 114 136 159 182 205 235 276 325 372 468 564 658 754 828 900 1090 1304 1500 1690 1880 60°C (140°F) 11 16 21 26 28 34 42 52 60 78 87 100 120 140 160 180 220 252 301 340 435 525 613 704 749 825 1000 1148 1320 1485 1650 Siemens Breaker Frames BQ, BL, BQD, CQD, GG, GB, ED FD QR JD LD MD ND PD RD Altitude in Feet (Meters) 13,000 (4,000) 12,000 (3,675) 11,000 (3,350) 10,000 (3,000) 9,000 (2,750) 8,000 (2,400) 7,000 (2,100) 6,000 (1,800) 1.0 .95 .90 .85 .80 .75 Rating Correction Factor Figure 1 -- Altitude Adjustment MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-169 Molded Case Circuit Breakers Unusual Operating Conditions 400 Hz Systemsa Siemens molded case circuit breakers can be applied for overcurrent protection on 400Hz systems, commonly used to power computer installations, aircraft, military and other specialty equipment. Below are basic guidelines. Circuit Breaker Derating Required This table lists the maximum continuous current carrying capacity for Siemens breakers at 400Hz. Due to the increased resistance of the copper sections resulting from the skin effect produced by eddy currents at these frequencies, circuit breakers in many cases require derating. The thermal derating on these devices is based upon 100%, three phase application in open air in a maximum of 40° C (104° F) with 48 in. (1219 mm) of the specified cable or bus at the line and load side. Additional derating of not less than 20% will be required if the circuit breaker is to be utilized in an enclosure. Further derating may be required if the enclosure Reference ambient temperature exceeds 40° C (104° F). Cable and Bus Sizing The cable and bus sizes to be utilized at 400Hz are not based on standard National Electric Codes tables for 60Hz application. Larger cross sections are necessary at 400Hz. All bus bars specified are based upon mounting the bars in the vertical plane to allow maximum air flow. All bus bars are spaced at a minimum of 0.25 in. (6 mm) apart. Mounting of bus bars in the horizontal plane will necessitate additional drafting. Edgewise orientation of the bus may change the maximum ratings indicated. If additional information is required for other connections of cable or bus, contact Siemens for information. Application Recommendations It is recommended that temperatures be measured on the line and load terminals or T-connectors of the center pole. These are usually the hottest terminals with a balanced load. A maximum temperature of 75° C (35° C over a maximum ambient of 40° C) would verify the particular application. Temperature profiles taken on these breakers can be correlated to ensure that the hottest points within the breaker are within the required temperature limits. Factory Configuration When required, molded case circuit breakers may be factory calibrated for 400Hz application. These breakers are specially labeled for 400Hz usage and their nameplate current rating will include the necessary derating factory. The highest "Maximum Continuous Amperes" rating at 400Hz, found in the table below approximates the highest specially calibrated 400Hz nameplate ampere rating available for a given frame size. Contact Siemens for ordering information on other breakers applied in 400Hz systems. MOLDED CASE 7 CIRCUIT BREAKERS 400Hz Breakers Maximum Continuous Ampere Rating At 40° C (104° F) b Siemens Breaker Type 60HZ Open Air 400HZ Open Air c Enclosed After Derating 015 015 012 020 020 016 025 025 020 030 030 024 035 035 028 040 040 032 ED2, ED4, ED6, 045 043 034 BQD, HED4, 050 048 038 HED6, CED6, GG, GB 060 057 046 070 067 054 080 076 061 090 086 069 100 095 076 110 105 084 125 119 095 070 063 050 080 072 058 090 080 064 QR2, QR2H, 100 090 072 HQR2, HQR2H, 110 095 075 FD6, FXF6, 125 105 084 HFD6, HFXD6, CFD6 150 125 100 175 140 112 200 160 128 225 180 144 250 200 160 200 170 136 JXD2, JD6, 225 190 152 JXD6, HJD6, 250 210 168 HJXD6, HHJD6, 300 240 192 HHJXD6, CJD6 350 260 208 400 300 240 200 170 170 JD6, JXD6, 225 190 190 HJD6, HJXD6 250 210 210 100% Rated 300 240 240 350 260 260 400 300 300 75°C (167° F) Copper Cable per Pole No of Pieces Wire Size 1 #14 1 #12 1 #10 1 #10 1 #10 1 #8 1 #8 1 #8 1 #6 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #4 1 #4 1 #3 1 #3 1 #2 1 #1 1 #1/0 1 #2/0 1 #3/0 1 #4/0 1 250 kcmil 1 #3/0 1 #4/0 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #3/0 2 #4/0 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 Siemens Breaker Type LD6, LXD6, HLD6, HLXD6, HHLD6, HHLXD6, CLD6 LD6, LXD6, HLD6, HLXD6, 100% Rated MD6, MXD6, HMD6, HMXD6, CMD6 MD6, MXD6, HMD6, HMXD6, CMD6 100% Rated ND6, NXD6 HND6, HNXD6, CND6 ND6, NXD6 HND6, HNXD6, CND6 100% Rated PD6, PXD6, HPD6, HPXD6, CPD6, PD6, PXD6, HPD6, HPXD6, CPD6 100% Rated RD6, RXD6, HRD6, HRXD6 80% Rated Maximum Continuous Ampere Rating At 40° C (104° F) b 60HZ 400/415HZ Open Air Open Air c Enclosed After Derating 0250 0210 168 0300 0240 192 0350 0260 208 0400 0300 240 0450 0340 272 0500 0375 300 0600 0420 336 0250 0210 210 0300 0240 240 0350 0260 260 0400 0300 300 0450 0340 340 0500 0375 375 0600 0420 420 0500 0400 320 0600 0430 360 0700 0500 400 0800 0560 448 0500 0400 400 0600 0430 430 0700 0500 500 0800 0560 560 0800 0560 448 0900 0600 480 1000 0650 520 1200 0780 624 0900 0600 600 1000 0650 650 1200 0780 780 1200 0780 624 1400 0850 680 1600 0960 768 1200 0780 780 1400 0850 850 1600 0960 960 1600 0960 768 1800 1080 864 2000 1200 960 75° C (167° F) Copper Cable per Pole No of Pieces Wire Size 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #4/0 2 250 kcmil 2 350 kcmil 1 250 kcmil 1 350 kcmil 1 500 kcmil 2 #3/0 2 #4/0 2 250 kcmil 2 350 kcmil 2 250 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 2 250 kcmil 2 350 kcmil 3 250 kcmil 3 300 kcmil 3 300 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 3 350 kcmil 3 400 kcmil 4 350 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil 4 400 kcmil 4 500 kcmil 5 500 kcmil 5 500 kcmil 5 500 kcmil 6 500 kcmil aThe information provided on this page is intended for reference and recommendation only. Because several variables can act on a circuit breaker's performance at the same time, the data above is based less on controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. bA dditional derating may be required if the ambient temperature is greater than 40°C (104°F). cC alculated after derating to compensate for the heating of the copper conductor, caused by the skin effect generated by eddy currents produced at 400/415HZ. 7-170 Siemens Industry, Inc. SPEEDFAXTM Product Catalog VL Circuit Breakers Catalog Numbering System Selection/Application Interrupting Class N -- Normal H -- High L -- Very High C -- Trip Unit Only Frame Family D -- Type DG F -- Type FG J -- Type JG L -- Type LG M -- Type MG N -- Type NG P -- Type PG Breaker Type E -- Global DG, FG Frame Only 600 Y/347 V G -- Global interchangeable (UL, IEC, CE, CSA, NOM, CCC) J -- 240V rated JG frame, Non-interchangeable only K -- Global, Non-interchangeable (DG, FG, LG-frame) M -- Motor Circuit Protector P -- Motor Circuit Protector (DG, FG Only) R-- Molded Case Switch (DG, FG, LG-frame) S -- Molded Case Switch T -- Trip Unit Only V -- Thermal Magnetic, standard 40°C ambient, 600VAC 25kA, UL/CSA (LG frame) W -- 100% rated, Non-interchangeable (DG, LG-frame) X -- Global Non-interchangeable Y -- 100% rated, Non-interchangeable Number of Poles 2, 3 Trip Unit F -- Frame only, without trip unit B -- Thermal Magnetic, standard 40° C ambient L -- Magnetic Only, Motor Circuit Protector - Low instantaneous range J -- Magnetic Only, Motor Circuit Protector - Low instantaneous range (LG-frame) M -- Magnetic Only, Motor Circuit Protector - Standard instantaneous range Y -- Magnetic Only, Motor Circuit Protector - Standard instantaneous range (LG-frame) H -- Magnetic Only, Motor Circuit Protector - High instantaneous range S -- Molded Case Switch A -- Electronic w/ LCD, LSI or 3P (neutral protected) G -- Electronic w/ LCD, LSIG, 3P/4W (selectable residual or return type ground fault protection) K -- Electronic with LCD, LSI and GF alarm only, 3P/4W (selectable residual or return type ground fault alarm) R -- Electronic LI or 3P (neutral protected) T -- Electronic LSI or 3P (neutral protected) V -- Electronic, LSIG or 3P/4W, residual ground fault protection W -- Electronic, LIG or 3P/4W, residual ground fault protection Continuous Current Rating For DG use 050, 060, 070, 080, 090, 100, 110, 125, 150 For FG use 100, 110, 125, 150, 175, 200, 225, 250 For JG use 250, 300, 350, 400 For LG use 400, 500, 600 For MG use 600, 700, 800 For NG use 800, 900, 100 (1000A), 120 (1200A) For PG use 120 (1200A), 140 (1400A), 160 (1600A) Terminations B -- Load End Standard (cu/al) Lugs L -- Line & Load Standard (cu/al) Lugs X -- No Lugs (use only if accessory suffixes are to follow) Accessories Auxiliary and Alarm Switch Combinations Suffix Description A1 -- 1 Alarm (includes 1NO & 1NC switch with a 2 Aux./1 Alarm Base, for frames DG to LG) A2 -- 2 Aux (1NO & 1NC switch with a 3 Aux. Base, for frames DG to LG) A3 -- 2 Aux + 1 Alarm (2NO & 2NC switches with a 2 Aux./1 Alarm Base, for frames DG to LG) A3 -- 2 Aux + 2 Alarm (2NO & 2NC switches with a 2 Aux./2 Alarm Base, for frames MG to PG) A4 -- 4 Aux (2NO & 2NC switches with a 4 Aux. Base, for frames MG to PG) Note: A1 and A3 include 1NO and 1NC switch for alarm purposes, only one of these switches may be used as there is only one space for an alarm. Shunt Trips RB -- 24 VDC RC -- 48-60 VDC RD -- 110-127 VDC RE -- 250 VDC RM -- 48-60 VAC RN -- 110-127 VAC RS -- 208-277 VAC RV -- 380-600 VAC Under Voltage Releases UA -- 12 VDC UN -- 110-127 VAC UB -- 24 VDC UP -- 208 VAC UC -- 48 VDC UR -- 220-250 VAC UD -- 110-127 VDC US -- 277 VAC UE -- 220-250 VDC UT -- 380-415 VAC UG -- 60 VDC UU -- 440-480 VAC UK -- 24 VAC LCD = Liquid Crystal Display LI = Long Delay & Instantaneous trip functions LSI = Long Delay, Short Delay, & Instantaneous trip functions LSIG = Long Delay, Short Delay, Instantaneous, & Ground Fault trip functions GF = Ground Fault 3P = 3-pole 4W = 4-wire Select Frames Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-171 MOLDED CASE 7 CIRCUIT BREAKERS VL Circuit Breakers Catalog Numbering System Selection If ordering factory-installed accessories or special modifications, you must order a 15-digit catalog number. See the examples below for a detailed explanation. The 15 digit number is achieved by placing X's in positions not being occupied by an accessory/modification. Contact Siemens for circuit breakers configured with accessories. Auxiliary Switch Example: HFG3B200L A2 XXXX Standard 9-digit Aux. Switch Completes Cat # Shunt Trip / UVR Example: HFG3B200L XX UN XX Standard 9-digit UVR Completes Cat # Shunt Trip / Auxiliary Switch Example: HFG3B200L A2 RN XX Standard 9-digit Aux. Shunt Completes Switch Trip Cat # Non-Interchangeable Trip Breakers Example: H F X 3 B 2 0 0 L Standard 9-digit MOLDED CASE 7 CIRCUIT BREAKERS 7-172 Siemens Industry, Inc. SPEEDFAXTM Product Catalog VL Circuit Breakers Technical Overview Frame Summary and Ratings Table Frame Family DG FG JG Continuous Ampere Range 30 to 150A 40 to 250A Number of Poles 2, 3 2, 3 Maximum Voltage Rating 600Y/347 600Y/347 Type of Protection Thermal-Magnetic u u Electronic u u Electronic with LCD u u Motor Circuit Protector u u Molded Case Switch u u 100% Rated Breaker ETU only -- Interchangeable Trip Unit -- -- W In.(mm) H D D1 4.1 (105) 7.3 (175) 3.4 (81) 4.2 (107) Type N Normal Interrupting Ratinga, RMS Symmetrical Amperes (kA) 240Vac 65 65 UL 480Vac 35 35 600Vac 18 18 240Vac 65/65 65/65 IEC (lCU/lCS) 415Vac 690Vac 40/40 12/6 40/40 12/6 DC Voltages Interrupting Rating (kA)d 250Vdc - 2p 30 30 500Vdc - 3pc 18 18 Type H High Interrupting Ratinga, RMS Symmetrical Amperes (kA) 240Vac 100 100 UL 480Vac 65 65 600Vac 18 18 240Vac 100/75 100/75 IEC (lCU/lCS) 415Vac 690Vac 70/70 12/6 70/70 12/6 DC Voltages Interrupting Rating (kA)d 250Vdc - 2p 30 30 500Vdc - 3pc 18 18 600Vdc - 3p 42 42 Type L Very High Interrupting Ratinga, RMS Symmetrical Amperes (kA) 240Vac 200 200 UL 480Vac 100 100 600Vac 18 18 240Vac 200/150 200/150 IEC (lCU/lCS) 415Vac 690Vac 100/75 12/6 100/75 12/6 DC Voltages Interrupting Rating (kA)d 250Vdc - 2p 30 30 500Vdc - 3pc 18 18 70 to 400A 2, 3 600V u u u u u u u 5.5 (139) 11 (279) 4.2 (102) 5.4 (138) 65 35 25 65/65 45/45 12/6 30 25 100 65 25 100/75 70/70 15/8 30 35 65 200 100 25 200/150 100/75 15/8 30 35 Revised on 10/31/21 Technical MOLDED CASE 7 CIRCUIT BREAKERS a UL does not recognize AIC ratings for Molded Case Switches or Motor Circuit Protectors. b For 600 VDC breakers see page 7-206. c 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. d DC Interruption Ratings do not apply to electronic trip circuit breakers. DG & FG breakers are 600Y/347V. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-173 VL Circuit Breakers Technical Overview Frame Summary and Ratings Table -- Continued Frame Family LG MG NG Technical PG Continuous Ampere Range 150 to 600A 200 to 800A Number of Poles 2, 3 2, 3 Maximum Voltage Rating 600V 600V Type of Protection Thermal-Magnetic u u Electronic u u Electronic with LCD u u Motor Circuit Protector u u Molded Case Switch u u 100% Rated 400/500 Amp u Interchangeable Trip Unit -- u W In.(mm) H D D1 5.5 (139) 11 (279) 4.2 (102) 5.4 (138) 7.5 (190) 16 (406) 4.7 (114) 5.9 (151) Type N Normal Interrupting Ratinga, RMS Symmetrical Amperes (kA) 240Vac 65 65 UL 480Vac 35 35 600Vac 18 25 240Vac 65/65 65/65 IEC (lCU/lCS) 415Vac 690Vac 45/45 12/6 50/50 20/10 DC Voltages Interrupting Rating (kA)d 250Vdc - 2p 30 22 500Vdc - 3pc 25 35 Type H High Interrupting Ratinga, RMS Symmetrical Amperes (kA) 240Vac 100 100 UL 480Vac 65 65 600Vac 18 35 240Vac 100/75 100/75 IEC (lCU/lCS) 415Vac 690Vac 70/70 15/8 70/70 30/15 DC Voltages Interrupting Rating (kA)d 250Vdc - 2p 30 25 500Vdc - 3pc 35 50 600Vdc - 3pe 65 65 Type L Very High Interrupting Ratinga, RMS Symmetrical Amperes (kA) 240Vac 200 200 UL 480Vac 100 100 600Vac 18 50 240Vac 200/150200/150 IEC (lCU/lCS) 415Vac 690Vac 100/75 15/8 100/75 35/17 DC Voltages Interrupting Rating (kA)d 250Vdc - 2p 30 42 500Vdc - 3pc 35 65 300 to 1200A 2, 3 600V 400 to 1600A 3 600V u u u u u u u -- u u u u u u 9 (229) 16 (406) 6.2 (157) 8.1 (207) 65 35 25 65/65 50/25 20/10 65 35 25 65/65 50/25 20/10 22 22 35 35 100 65 35 100/75 70/35 30/15 100 65 35 100/50 70/35 30/15 25 25 50 50 65 65 200 100 65 200/150 100/75 35/17 200 100 65 200/150 100/75 35/17 42 42 65 65 MOLDED CASE 7 CIRCUIT BREAKERS a UL does not recognize AIC ratings for Molded Case Switches or Motor Circuit Protectors. b 25kA available in a special version. Standard breakers rated 18kA. See page 7-190. c 500Vdc nominal, 600Vdc max. for ungrounded DC UPS systems. d DC Interruption Ratings do not apply to electronic trip circuit breakers. 7-174 Siemens Industry, Inc. SPEEDFAXTM Product Catalog e For 600 VDC breakers see page 7-206. Thermal-magnetic available non-interchangeable only. 13.6" with extended shields. VL Circuit Breakers Trip Unit Overview Selection The interchangeability of the VL circuit breaker trip units allow for easy conversion from any of 3 types of protection. They are thermal-magnetic, electronic, or electronic with a built-in LCD. The thermal-magnetic trip unit features an adjustable magnetic trip setting. The electronic trip units are microprocessor based true RMS sensing devices and are available with a variety of adjustable trip settings, configurations, and infor- mation menus. With precise control over the circuit beaker functions and access to system status, diagnostics, and information, these trip units allow for unsurpassed flexibility in circuit coordination. An example of coordination is the out of the box Ground Fault function on the Model 555 trip units. The pick-up and time delay settings are set at the factory for each frame and do not overlap with the settings on the other frames. Therefore, when VL breakers are used together in a system the GF protection is automatically coordinated. The user also has the ability to program a custom coordination scheme with adjustable settings on both the 555 and 586 trip units. VL Trip Units Trip Unit Functions Model 525 Model 555 Thermalmagnetic Electronic Electronic Electronic LI LIG LSI Continuous Current Setting (Ir) Fixed u u u Long Time Delay (tr) h u u u Instantaneous Function l l l l Instantaneous Pickup (Ii) Short Time Function u u u u h h h l Short Time Pick-up (Isd) h h h u Short Time Delay (tsd) h h h u Ground Fault Pick-up (Ig) h h u h Ground Fault Delay (tg) h h u h Ground Fault Alarm Pick-up h h h h Ground Fault Alarm Delay h h h h Alarm & Status Indicator h l l l Built-in Display (LCD) h h h h Pre-Trip Alarma h l l l Last Trip Information h la la la Zone Selectivea h l l l Communicationsa h l l l u Adjustable setting l This feature is included h Feature is not included. a Requires a COMPRO20 or COMMOD21 module in a communication system. Electronic LSIG u u l u l u u u u h h l h l la l l Electronic with LCD LSI u u (ON/OFF) u (ON/OFF) u u h h h h l l l l l l Model 586 Electronic with LCD LSIG Electronic with LCD LSI + G alarm only u u u u (ON/OFF) (ON/OFF) u u (ON/OFF) (ON/OFF) u u u u u h u h u u u u l l l l l l l l l l l l MOLDED CASE 7 CIRCUIT BREAKERS Continuous Amps Rating (Ir) This setting is the continuous current that the breaker will carry without tripping. It can be set up to 100% of the trip unit's nominal rating (In). Long Time Delay (tr) Sometimes referred to as the "overload" position, this function controls the breaker`s "pause-in-tripping" time. It allows low level, temporary inrush currents such as those encountered when starting a motor to pass without tripping. The time delay begins when the current reaches 6 x Ir. Instantaneous Pick-up (Ii) This function sets the breaker to trip instantaneously during high fault conditions. This function may be turned off on Model 586 trip units. Turning this function off will enable an instantaneous trip override function to ensure self protection of circuit breaker. Short Time Pick-Up (lsd) This function controls the level of fault current the breaker will carry for a short time without tripping, thus allowing downstream devices to clear short circuits ahead of up-stream protection. It may be defeated (turned-off) on Model 586 trip units. Short Time Delay (tsd) This controls the interval of time the breaker will remain closed against a fault (at the Short Time Pick-up current level) without tripping. The time delay may be set at fixed points or at short time intervals based on l2t curves. This function is used with the Short Time Pick-up to achieve selectivity and better system coordination. Ground Fault Pick-Up (Ig) This setting controls the level of ground fault current that will cause the breaker to trip. Model 555 Electronic Trip Units act on the residual current to sense ground current. The Model 586 Electronic Trip Unit is programmable and allows the user to select either the residual current method or direct detection (via a separate current transformer) to detect ground current. Ground Fault Time Delay (tg) This controls the interval of time the breaker will remain closed after a ground fault is detected (at the Ground Fault Pick-up current level) without tripping. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-175 VL Circuit Breakers General Information Selection Thermal-Magnetic trip units, Model 525, combine the inverse time element design for low level overloads, and instantaneous magnetic action for short circuit protection. The standard unit has preset overload protection and an adjustable instantaneous trip setting, with 6 set points. Thermal-Magnetic trip units are available throughout the VL family, from 50 to 1600A. Electronic Trip Units Electronic trip units are available through the VL family, from 60A (which can be set as low as 30A) up through 1600A. They are also available in four trip configurations (LI, LIG, LSI, LSIG) and features can include a built-in LCD display. On the Model 555 Electronic Trip Unit a flashing LED confirms that the microprocessor is in operating and another indicates an overload condition. For ease-of-use and to insure proper coordination, the set points for the continuous current are shown on the face of these trip units in amps. On the Model 586, the LCD version, the current in each phase is continuously shown on the display. Unlike many Typical Trip Unit Labeling and Adjustment Positions displays, no secondary or auxiliary voltage is required as long as the breaker is energized and a minimal load current is present. These trip units can also indicate the "last trip" status (date, time, amps) when they`re connected to a PC via one of our communications modules. Without being connected via a communication module, the last trip status can be viewed on Model 586 trip units (no time stamp). Model 555 Electronic Trip Unit with LSIG trip functions Model 586 Electronic Trip Unit has an LCD display MOLDED CASE 7 CIRCUIT BREAKERS 7-176 Siemens Industry, Inc. SPEEDFAXTM Product Catalog MOLDED CASE 7 CIRCUIT BREAKERS Phase-out October 2022 VL Circuit Breakers DG 150A Frame, VL Series Ordering Information Complete Assembled Breaker A complete factory assembled DG breaker includes the frame, trip unit, and standard line and load connectors, all factory installed and shipped as a complete breaker. Assembled breakers are only available with standard connectors. For DC applications, use thermal magnetic trip unit only. Breakers are suitable for reverse feed applications. For special applications, refer to page 7-224. Mounting hardware is included with each frame or complete breaker. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to "W". Available in electronic and electronic with LCD only. HACR rated. Revised on 07/31/21 Selection Interrupting Ratings Interrupting Class N H L Breaker Type NDGB HDGB LDGB RMS Symmetrical Amperes (KA) UL 489 Volts AC (50/60 Hz) Volts DC 240 65 100 200 480 35 65 100 600Y /347 18 18 18 250 30 30 30 500 18 18 18 IEC 60947-2 Volts AC (50/60 Hz) 220/240 380/415 ICU ICS ICU ICS 65 65 40 40 100 75 70 70 200 150 100 75 690 ICU 12 12 12 ICS 6 6 6 Connectors for 75°C Wire Construction Ampere Rating Steel 30-150 Aluminum 30-150 Copper 30-150 Distribution Lugs 30-150 30-150 Compression Lugs 30-150 30-150 Wire Range #81/0 Cu #63/0 Al/Cu #63/0 Cu No. of cables per connector 1 1 1 #14#2 Al/Cu (3pcs. Max) 3 #14#4 Cu, #14#6 Al 6 #142/0 kcmil Al/Cu #142/0 kcmil Al/Cu Catalog Number 3TW1DG20b 3TA1DG30 3TC1DG30b 3TA3DG02b 3TA6DG04b 2CLD20c 3CLD20b a Standard connector supplied with complete breakers. b Kit consists of 3 terminal connectors. c 2 Lugs for 2-pole breakers. d Required for 100% rated DG breakers. Requires 90°C Cu cable sized at 75°C ampacity DG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 50 60 Instantaneous Overcurrent Setting (Ii) Min. Max. 450 600 450 600 70 450 700 80 450 800 90 500 1000 100 500 1000 110 550 1100 125 625 1250 150 800 1600 Note: Each breaker has 6 trip settings in this range. Dimensions, inches (mm) Number To Handle of Poles Width Length Depth D1 2, 3 4.1 (105) 6.9 (175) 3.4 (81) 4.2(107) Approx. Shipping Weight, lbs. (kg) Trip Unit Complete Poles Frame Thermal-Mag. Electronic Breaker 2, 3 3.7 (1.7) 2.2 (1.0) 2.6 (1.2) 5.9 (2.7) External Accessories pages 7-207 through 7-219 Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-177 Phase-out October 2022 VL Circuit Breakers DG 150A Thermal-Magnetic Trip Unit Revised on 07/31/21 Selection Ii AMPS 1120 1280 960 1440 I n =150A 40? C TM ~ 800 1600 TRIP UNIT/DISPARADOR 525 DG 150A Frame 2-Pole with Thermal-Magnetic Trip Unit Model 525Trip Unit Continuous Ampere Rating 50 60 70 80 90 100 110 125 150 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER N-Interrupting Class Catalog Number NDK2B050L NDK2B060L NDK2B070L NDK2B080L NDK2B090L NDK2B100L NDK2B110L NDK2B125L NDK2B150L H-Interrupting Class Catalog Number HDK2B050L HDK2B060L HDK2B070L HDK2B080L HDK2B090L HDK2B100L HDK2B110L HDK2B125L HDK2B150L L-Interrupting Class Catalog Number LDK2B050L LDK2B060L LDK2B070L LDK2B080L LDK2B090L LDK2B100L LDK2B110L LDK2B125L LDK2B150L DG 150A Frame 3-Pole with Thermal-Magnetic Trip Unit Continuous Ampere Rating 50 60 70 80 90 100 110 125 150 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER N-Interrupting Class Catalog Number NDK3B050L NDK3B060L NDK3B070L NDK3B080L NDK3B090L NDK3B100L NDK3B110L NDK3B125L NDK3B150L H-Interrupting Class Catalog Number HDK3B050L HDK3B060L HDK3B070L HDK3B080L HDK3B090L HDK3B100L HDK3B110L HDK3B125L HDK3B150L L-Interrupting Class Catalog Number LDK3B050L LDK3B060L LDK3B070L LDK3B080L LDK3B090L LDK3B100L LDK3B110L LDK3B125L LDK3B150L Type / Tipo CDT3 Cat. No. - CDT3B150 MOLDED CASE 7 CIRCUIT BREAKERS 7-178 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB VL Circuit Breakers DG 150A Electronic Trip Units Revised on 07/31/21 Selection MOLDED CASE 7 CIRCUIT BREAKERS Phase-out October 2022 DG 150A Frame 3-Pole Electronic Trip Unita Model 555Trip Units Continuous Ampere Rating 60 100 150 60 100 150 60 100 150 60 100 150 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER N-Interrupting Class H-Interrupting Class Catalog Number Catalog Number ELECTRONIC LI TRIP NDK3R060L HDK3R060L NDK3R100L HDK3R100L NDK3R150L HDK3R150L ELECTRONIC LSI TRIP NDK3T060L HDK3T060L NDK3T100L HDK3T100L NDK3T150L HDK3T150L ELECTRONIC LSIG TRIP NDK3V060L HDK3V060L NDK3V100L HDK3V100L NDK3V150L HDK3V150L ELECTRONIC LIG TRIP NDK3W060L HDK3W060L NDK3W100L HDK3W100L NDK3W150L HDK3W150L L-Interrupting Class Catalog Number LDK3R060L LDK3R100L LDK3R150L LDK3T060L LDK3T100L LDK3T150L LDK3V060L LDK3V100L LDK3V150L LDK3W060L LDK3W100L LDK3W150L DG 150A Frame 3-Pole Electronic LCD Trip Unita Model 586Trip Unit Continuous Ampere Rating 60 100 150 60 100 150 60 100 150 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER N-Interrupting Class H-Interrupting Class Catalog Number Catalog Number LCD ELECTRONIC LSI TRIP NDK3A060L HDK3A060L NDK3A100L HDK3A100L NDK3A150L HDK3A150L LCD ELECTRONIC LSIG TRIP NDK3G060L HDK3G060L NDK3G100L HDK3G100L NDK3G150L HDK3G150L LCD ELECTRONIC LSI TRIP + GF ALARM ONLY NDK3K060L HDK3K060L NDK3K100L HDK3K100L NDK3K150L HDK3K150L L-Interrupting Class Catalog Number LDK3A060L LDK3A100L LDK3A150L LDK3G060L LDK3G100L LDK3G150L LDK3K060L LDK3K100L LDK3K150L a Due to the location of the magnetic tripping solenoid, the left accessory pocket is not available for accessories. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-179 Phase-out October 2022 VL Circuit Breakers Internal Accessories for DG 150A and FG 250A Frames Auxiliary Switch and Alarm Switch Combination Kits Description 1 Alarm Switch 1A/Bc Bases AMBL2 & AMBL3 2 Aux. Switches 1A + 1B Bases AMBL1 2 Aux. + 1 Alarm Switch 1A + 1B, 1A/Bc Bases AMBL2 & AMBL3 Mounting Pocketa Left, Rightb Left, Right Left, Rightb Catalog Number ASKL1 ASKL2 ASKL3 Auxiliary/Alarm Switch Mounting Base Only Description Up to 3 Auxiliary Switches 2 Aux. + 1 Alarm Switch 2 Aux. + 1 Alarm Switch Mounting Pocket Left, Right Left Pocket Only Right Pocket Only Catalog Number AMBL1 AMBL2 AMBL3 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Shunt Trips Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Mounting Pocket Right Pocket Only Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 24 VAC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC Mounting Pocket Right Pocket Only Catalog Number ASWPA ASWPB Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLL24 UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 Revised on 07/31/21 Selection UVRLN120 MOLDED CASE 7 CIRCUIT BREAKERS a Refer to the "Accessory Locations" chart on page 7-220 for guidelines and limitations about which pockets may be used for accessory combinations. b These kits include two bases, one for mounting switches in the left pocket and another for mounting in the right. c Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. `A' refers to a normally open contact (open when the breaker contacts are open). `B' refers to a normally closed contact (closed when the breaker contacts are open). External Accessories pages 7-207 through 7-219 7-180 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB MOLDED CASE 7 CIRCUIT BREAKERS Phase-out October 2022 VL Circuit Breakers FG 250A Frame, VL Series Ordering Information Complete Assembled Breaker A complete factory assembled FG breaker includes the frame, trip unit, and standard line and load connectors, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For DC applications, use thermal magnetic trip unit only. Breakers are suitable for reverse feed applications. For special applications, refer to page 7-224. Mounting hardware is included with each frame or complete breaker. HACR rated. Interrupting Ratings Breaker Type NFG HFG LFG RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 600Y/ 220/240 380/415 240 480 347 250 500 ICU ICS ICU ICS 65 35 18 30 18 65 65 40 40 100 65 18 30 18 100 75 70 70 200 100 18 30 18 200 150 100 75 690 ICU ICS 12 6 12 6 12 6 Connectors for 75°C Wire Ampere Construction Rating Steel 50-250 Aluminum 50-250 Copper 50-250 Distribution Lugs 50-250 50-250 Wire Range #4350 kcmil Cu #4350 kcmil Al/Cu #4350 kcmil Cu #122/0 Cu/Al #14#4 Cu/Al Standard connector supplied with complete breakers. Kit consists of 3 terminal connectors. 2 Lugs for 2-pole breakers. 3 Lugs for 3-pole breakers. No. of cables per connector 1 1 1 3 6 Catalog Number 3TW1FG350 3TAW1FG350 3TCW1FG350 3TA3FG20 3TA6FG04 Revised on 07/31/21 Selection/Dimensions Dimensions, inches (mm) Number To Handle of Poles Width Length Depth D1 2, 3 4.1 (105) 6.9 (175) 3.4 (81) 4.2 (107) Shipping Weight, lbs. (kg) Trip Unit Complete Poles Frame Thermal-Mag. Electronic Breaker 2, 3 4.0 (1.8) 2.2 (1.0) 2.6 (1.2) 6.2 (2.8) FG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 100 Instantaneous Overcurrent Setting (Ii) Min. Max. 625 1250 110 800 1600 125 800 1600 150 800 1600 175 1000 2000 200 1000 2000 225 1250 2500 250 1250 2500 Note: Each breaker has 6 trip settings in this range. Product Category MCCB External Accessories pages 7-207 through 7-219 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-181 Phase-out October 2022 VL Circuit Breakers FG 250A Thermal-Magnetic Trip Unit Revised on 07/31/21 Selection Ii AMPS 1750 2000 1500 2250 I n =250A 40? C TM ~ 1250 2500 TRIP UNIT/DISPARADOR 525 Type / Tipo CFT3 Cat. No. - CFT3B250 FG 250A Frame 2-Pole with Thermal-Magnetic Trip Unit Model 525Trip Unit Continuous Ampere Rating 100 110 125 150 175 200 225 250 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER N-Interrupting Class Catalog Number NFK2B100L NFK2B110L NFK2B125L NFK2B150L NFK2B175L NFK2B200L NFK2B225L NFK2B250L H-Interrupting Class Catalog Number HFK2B100L HFK2B110L HFK2B125L HFK2B150L HFK2B175L HFK2B200L HFK2B225L HFK2B250L L-Interrupting Class Catalog Number LFK2B100L LFK2B110L LFK2B125L LFK2B150L LFK2B175L LFK2B200L LFK2B225L LFK2B250L FG 250A Frame 3-Pole with Thermal-Magnetic Trip Unit Continuous Ampere Rating 100 110 125 150 175 200 225 250 0 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER N-Interrupting Class Catalog Number NFK3B100L NFK3B110L NFK3B125L NFK3B150L NFK3B175L NFK3B200L NFK3B225L NFK3B250L H-Interrupting Class Catalog Number HFK3B100L HFK3B110L HFK3B125L HFK3B150L HFK3B175L HFK3B200L HFK3B225L HFK3B250L L-Interrupting Class Catalog Number LFK3B100L LFK3B110L LFK3B125L LFK3B150L LFK3B175L LFK3B200L LFK3B225L LFK3B250L MOLDED CASE 7 CIRCUIT BREAKERS 7-182 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB VL Circuit Breakers FG 250A Electronic Trip Units Revised on 07/31/21 Selection MOLDED CASE 7 CIRCUIT BREAKERS Phase-out October 2022 FG 250A Frame 3-Pole Electronic Trip Unita Model 555Trip Units Continuous Ampere Rating 100 150 250 100 150 250 100 150 250 100 150 250 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER N-Interrupting Class H-Interrupting Class Catalog Number Catalog Number ELECTRONIC LI TRIP NFK3R100L HFK3R100L NFK3R150L HFK3R150L NFK3R250L HFK3R250L ELECTRONIC LSI TRIP NFK3T100L HFK3T100L NFK3T150L HFK3T150L NFK3T250L HFK3T250L ELECTRONIC LSIG TRIP NFK3V100L HFK3V100L NFK3V150L HFK3V150L NFK3V250L HFK3V250L ELECTRONIC LIG TRIP NFK3W100L HFK3W100L NFK3W150L HFK3W150L NFK3W250L HFK3W250L L-Interrupting Class Catalog Number LFK3R100L LFK3R150L LFK3R250L LFK3T100L LFK3T150L LFK3T250L LFK3V100L LFK3V150L LFK3V250L LFK3W100L LFK3W150L LFK3W250L FG 250A Frame 3-Pole Electronic LCD Trip Unita Model 586Trip Unit Continuous Ampere Rating 100 150 250 100 150 250 100 150 250 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER N-Interrupting Class H-Interrupting Class Catalog Number Catalog Number LCD ELECTRONIC LSI TRIP NFK3A100L HFK3A100L NFK3A150L HFK3A150L NFK3A250L HFK3A250L LCD ELECTRONIC LSIG TRIP NFK3G100L HFK3G100L NFK3G150L HFK3G150L NFK3G250L HFK3G250L LCD ELECTRONIC LSI TRIP + GF ALARM ONLY NFK3K100L HFK3K100L NFK3K150L HFK3K150L NFK3K250L HFK3K250L L-Interrupting Class Catalog Number LFK3A100L LFK3A150L LFK3A250L LFK3G100L LFK3G150L LFK3G250L LFK3K100L LFK3K150L LFK3K250L a Due to the location of the magnetic tripping solenoid, the left accessory pocket is not available for accessories. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-183 Phase-out October 2022 VL Circuit Breakers Internal Accessories for DG 150A and FG 250A Frames Auxiliary Switch and Alarm Switch Combination Kits Description 1 Alarm Switch 1A/Bc Bases AMBL2 & AMBL3 2 Aux. Switches 1A + 1B Bases AMBL1 2 Aux. + 1 Alarm Switches 1A + 1B, 1A/Bc Bases AMBL2 & AMBL3 Mounting Pocketa Left, Rightb Left, Right Left, Rightb Catalog Number ASKL1 ASKL2 ASKL3 Auxiliary/Alarm Switch Mounting Base Only Description Up to 3 Auxiliary Switches 2 Aux. + 1 Alarm Switch 2 Aux. + 1 Alarm Switch Mounting Pocket Left, Right Left Pocket Only Right Pocket Only Catalog Number AMBL1 AMBL2 AMBL3 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB Shunt Trips Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Mounting Pocket Right Pocket Only Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 24 VAC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC Mounting Pocket Right Pocket Only Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLL24 UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 Revised on 07/31/21 Selection UVRLN120 MOLDED CASE 7 CIRCUIT BREAKERS a Refer to the "Accessory Locations" chart on page 7-220 for guidelines and limitations about which pockets may be used for accessory combinations. b These kits include two bases, one for mounting switches in the left pocket and another for mounting in the right. c Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. `A' refers to a normally open contact (open when the breaker contacts are open). `B' refers to a normally closed contact (closed when the breaker contacts are open). 7-184 Siemens Industry, Inc. SPEEDFAXTM Product Catalog External Accessories pages 7-207 through 7-219 Product Category MCCB MOLDED CASE 7 CIRCUIT BREAKERS Phase-out October 2022 VL Circuit Breakers JG 400A Frame, VL Series Ordering Information Complete Assembled Breaker A complete factory assembled JG breaker includes the frame, trip unit, and standard line and load connectors, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to "X" for standard breakers. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to "Y" (3-pole only). For special applications, refer to page 7-224. Mounting hardware is included with each frame or complete breaker. HACR rated. Interrupting Ratings Interrupting Class N H L Breaker Type NJGA HJGA LJGA RMS Symmetrical Amperes (KA) UL 489 AIR (File E10848) Volts AC (50/60 Hz) Volts DC 240 480 600 250 500 65 35 25 30 25 100 65 25 30 35 200 100 25 30 35 IEC 60947-2 Volts AC (50/60 Hz) 220/240 380/415 ICU ICS ICU ICS 65 65 45 45 100 75 70 70 200 150 100 75 690 ICU ICS 12 6 15 8 15 8 Connectors for 75°C Wire Ampere Construction Rating Steel Aluminum Aluminum Aluminum Copper 70-400 70-400 70-400 70-400 70-400 Copper 70-400 Distribution Lugs 70-400 70-400 Compression Lugs 70-400 70-400 Wire Range 1/0600 kcmil Cu 3/0250 kcmil Al/Cu 250750 kcmil Al 3/0600 kcmil Cu 3/0600 kcmil Cu 3/0250 kcmil Cu #144 Cu #142/0 Al/Cu #6350 kcmil 250-600 kcmil a Standard construction supplied for each breaker. b Kit consists of 3 terminal connectors. c Required for 100% rated JG breakers. Requires 90°C Cu cable sized at 75°C ampacity. No. of cables per connector 1 2 1 1 1 2 12 6 -- -- Catalog Number 3TW1JG600b 3TA2JG250ab 3TA1JG750b 3TA1JG750b TC1JG750 TC2JG250 3TA12JG04b 3TA6JG20b 3CLJ350b 3CLJ600b Revised on 07/31/21 Selection/Dimensions Dimensions, inches (mm) Number To Handle of Poles Width Length Depth D1 2, 3 5.5 (139) 11 (279) 4.2 (102) 5.4 (138) Shipping Weight, lbs. (kg) Trip Unit Complete Poles Frame Thermal-Mag. Electronic Breaker 2, 3 9.3 (4.2) 4.0 (1.8) 4.0 (1.8) 12.6 (5.7) JG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 250 Instantaneous Overcurrent Setting (Ii) Min. Max. 1250 2500 300 1500 3000 350 1750 3500 400 2000 4000 Note: Each breaker has 6 trip settings in this range. Product Category MCCB External Accessories pages 7-207 through 7-219 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-185 VL Circuit Breakers JG 400A Thermal-Magnetic Trip Unit Revised on 07/31/21 Selection Phase-out October 2022 MOLDED CASE 7 CIRCUIT BREAKERS JG 400A Frame 2-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class H-Interrupting Class Model 525Trip Unit L-Interrupting Class Continuous Ampere Rating 250 300 350 400 Catalog Number Catalog Number Catalog Number FRAME ONLY NJG2F400 HJG2F400 LJG2F400 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NJG2B250L NJG2B300L NJG2B350L NJG2B400L HJG2B250L HJG2B300L HJG2B350L HJG2B400L LJG2B250L LJG2B300L LJG2B350L LJG2B400L JG 400A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 250 300 350 400 Catalog Number Catalog Number Catalog Number FRAME ONLY NJG3F400 HJG3F400 LJG3F400 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NJG3B250L NJG3B300L NJG3B350L NJG3B400L HJG3B250L HJG3B300L HJG3B350L HJG3B400L LJG3B250L LJG3B300L LJG3B350L LJG3B400L JJ 400A Frame 240V max., 2-pole with Thermal-Magnetic Non-Interchangeable Trip Unit N-Interrupting Class Continuous Ampere Rating 250 300 350 400 Catalog Number COMPLETE BREAKER NJJ2B250 NJJ2B300 NJJ2B350 NJJ2B400 JJ 400A Frame 240V max., 3-pole with Thermal-Magnetic Non-Interchangeable Trip Unit N-Interrupting Class Continuous Ampere Rating 250 300 350 400 Catalog Number COMPLETE BREAKER NJJ3B250 NJJ3B300 NJJ3B350 NJJ3B400 Catalog Number TRIP UNIT ONLY CJT2B250 CJT2B300 CJT2B350 CJT2B400 Catalog Number TRIP UNIT ONLY CJT3B250 CJT3B300 CJT3B350 CJT3B400 Terminal connectors must be ordered separately. Breaker Type NJJA. 7-186 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB MOLDED CASE 7 CIRCUIT BREAKERS Phase-out October 2022 VL Circuit Breakers JG 400A Electronic Trip Units Revised on 07/31/21 Selection Model 555Trip Units JG 400A Frame 3-Pole Electronic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 250 400 250 400 250 400 250 400 Catalog Number Catalog Number Catalog Number FRAME ONLY NJG3F400 HJG3F400 LJG3F400 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NJG3R250L NJG3R400L NJG3T250L NJG3T400L NJG3V250L NJG3V400L NJG3W250L NJG3W400L ELECTRONIC LI TRIP HJG3R250L HJG3R400L ELECTRONIC LSI TRIP HJG3T250L HJG3T400L ELECTRONIC LSIG TRIP HJG3V250L HJG3V400L ELECTRONIC LIG TRIP HJG3W250L HJG3W400L LJG3R250L LJG3R400L LJG3T250L LJG3T400L LJG3V250L LJG3V400L LJG3W250L LJG3W400L Catalog Number TRIP UNIT ONLY CJT3R250 CJT3R400 CJT3T250 CJT3T400 CJT3V250 CJT3V400 CJT3W250 CJT3W400 JG 400A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class H-Interrupting Class Model 586Trip Unit L-Interrupting Class Continuous Ampere Rating 250 400 250 400 250 400 Catalog Number Catalog Number Catalog Number FRAME ONLY NJG3F400 HJG3F400 LJG3F400 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NJG3A250L NJG3A400L NJG3G250L NJG3G400L NJG3K250L NJG3K400L LCD ELECTRONIC LSI TRIP HJG3A250L HJG3A400L LCD ELECTRONIC LSIG TRIP LJG3A250L LJG3A400L HJG3G250L LJG3G250L HJG3G400L LJG3G400L LCD ELECTRONIC LSI TRIP + GF ALARM ONLY HJG3K250L HJG3K400L LJG3K250L LJG3K400L Catalog Number TRIP UNIT ONLY CJT3A250 CJT3A400 CJT3G250 CJT3G400 CJT3K250 CJT3K400 Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-187 Phase-out October 2022 VL Circuit Breakers Internal Accessories for JG 400A and LG 600A Frames Auxiliary Switch and Alarm Switch Combination Kits Description 1 Alarm Switch 1A/Bc Bases AMBL2 & AMBL3 2 Aux. Switches 1A + 1B Bases AMBL1 2 Aux. + 1 Alarm Switches 1A + 1B, 1A/B Bases AMBL2 & AMBL3 Mounting Pocketa Left, Rightb Left, Right Left, Rightb Catalog Number ASKL1 ASKL2 ASKL3 Auxiliary/Alarm Switch Mounting Base Only Description Up to 3 Auxiliary Switches 2 Aux. + 1 Alarm Switch 2 Aux. + 1 Alarm Switch Mounting Pocket Left, Right Left Pocket Only Right Pocket Only Catalog Number AMBL1 AMBL2 AMBL3 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB Shunt Trips Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Mounting Pocket Right Pocket Only Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 24 VAC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC Mounting Pocket Right Pocket Only Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLL24 UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 Revised on 07/31/21 Selection UVRLN120 MOLDED CASE 7 CIRCUIT BREAKERS a Refer to the "Accessory Locations" chart on page 7-220 for guidelines and limitations about which pockets may be used for accessory combinations. b Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. `A' refers to a normally open contact (open when the breaker contacts are open). `B' refers to a normally closed contact (closed when the breaker contacts are open). 7-188 Siemens Industry, Inc. SPEEDFAXTM Product Catalog External Accessories pages 7-207 through 7-219 Product Category MCCB MOLDED CASE 7 CIRCUIT BREAKERS Phase-out October 2022 VL Circuit Breakers LG 600A Frame, VL Series Ordering Information Complete Assembled Breaker A complete factory assembled LG breaker includes the frame, trip unit, and standard line and load lugs, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For DC applications, use thermal magnetic trip unit only. Breakers are suitable for reverse feed applications. For special applications, refer to page 7-224. Mounting hardware is included with each breaker. For 100% rated breakers, change the 3rd character of the catalog number to "W". Available on 400/500 Amp only (3-pole only). HACR rated. Revised on 07/31/21 Selection/Dimensions Interrupting Ratings RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) Interrupting Breaker Class Type N NLGB 220/240 380/415 690 240 480 600 250 500 ICU ICS ICU ICS ICU ICS 65 35 18 30 25 65 65 45 45 12 6 H HLGB 100 65 18 30 35 100 75 70 70 15 8 L LLGB 200 100 18 30 35 200 150 100 75 15 8 Special 600Vac 25kA thermal-magnetic version (Type HLGC) available, see page 7-190. Connectors for 75°C Wire Construction Ampere Rating Aluminum Aluminum Copper Copper 150-600 150-600 150-600 150-600 Compression Lugs 150-600 150-600 150-600 Wire Range #2600 kcmil Al/Cu #2600 kcmil Al/Cu #2600 kcmil Cu #2600 kcmil Cu #6350 kcmil Al/Cu 250-750 kcmil Al/Cu 250-600 kcmil Al/Cu No. of cables per connector 2 (load side) 2 (line side) 2 (load side) 2 (line side) -- -- -- Standard construction supplied for each breaker. Kit consists of 3 terminal connectors. Kit consists of 6 lugs for Line or Load end. Required for 100% rated LG breakers. Requires 90°C Cu cable sized at 75°C ampacity. Catalog Number 3TA2LG600LD 3TA2LG600LN 3TC2LG600LD 3TC2LG600LN 6CLL350 3CLL750 6CLL600 LG Thermal-Magnetic, Instantaneous Trip Adjustment Range Trip Unit Continuous Amp Rating (In) 400 500 Instantaneous Overcurrent Setting (Ii) Min. Max. 2000 2500 4000 5000 600 2750 5500 Note: Each breaker has 6 trip settings. Dimensions, inches (mm) Number To Handle of Poles Width Length Depth D1 2, 3 Ext. Shield 5.5 (139) 11 (279) 4.2 (102) 5.4 (138) 13.6 (345.5) Shipping Weight, lbs. (kg) Trip Unit Complete Poles Frame Thermal-Mag. Electronic Breaker 2, 3 17.4 (7.9) 3.5 (1.6) 4.2 (1.9) 20.9 (9.5) Product Category MCCB External Accessories pages 7-207 through 7-219 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-189 VL Circuit Breakers LG 600A Thermal-Magnetic Trip Unit Revised on 07/31/21 Selection Phase-out October 2022 MOLDED CASE 7 CIRCUIT BREAKERS Model 525Trip Unit LG 600A Frame 2-Pole with Thermal-Magnetic Trip Unit Continuous Ampere Rating 400 500 600 N-Interrupting Class Catalog Number NLK2B400L NLK2B500L NLK2B600L H-Interrupting Class Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER HLK2B400L HLK2B500L HLK2B600L L-Interrupting Class Catalog Number LLK2B400L LLK2B500L LLK2B600L LG 600A Frame 3-Pole with Thermal-Magnetic Trip Unit Continuous Ampere Rating 400 500 600 N-Interrupting Class Catalog Number NLK3B400L NLK3B500L NLK3B600L H-Interrupting Class Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER HLK3B400L HLK3B500L HLK3B600L L-Interrupting Class Catalog Number LLK3B400L LLK3B500L LLK3B600L Type HLGC 600A Frame 2-Pole with Thermal-Magnetic Trip Unit , 600Vac 25kA only Continuous Ampere Rating 400 500 600 N-Interrupting Class Catalog Number -- -- -- H-Interrupting Class Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER HLV2B400L HLV2B500L HLV2B600L L-Interrupting Class Catalog Number -- -- -- Type HLGC 600A Frame 3-Pole with Thermal-Magnetic Trip Unit , 600Vac 25kA only Continuous Ampere Rating 400 500 600 N-Interrupting Class Catalog Number -- -- -- H-Interrupting Class Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER HLV3B400L HLV3B500L HLV3B600L L-Interrupting Class Catalog Number -- -- -- For 100% rated 400A or 500A versions, change the third character of the catalog number to "Z". Consult sales office for availability. 7-190 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB MOLDED CASE 7 CIRCUIT BREAKERS Phase-out October 2022 VL Circuit Breakers LG 600A Electronic Trip Units Revised on 07/31/21 Selection Model 555Trip Unit LG 600A Frame 3-Pole Electronic Trip Unit Continuous Ampere Rating 400 600 400 600 400 600 400 600 N-Interrupting Class H-Interrupting Class Catalog Number Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER ELECTRONIC LI TRIP NLK3R400L NLK3R600L HLK3R400L HLK3R600L ELECTRONIC LSI TRIP NLK3T400L NLK3T600L HLK3T400L HLK3T600L ELECTRONIC LSIG TRIP NLK3V400L NLK3V600L HLK3V400L HLK3V600L ELECTRONIC LIG TRIP NLK3W400L NLK3W600L HLK3W400L HLK3W600L L-Interrupting Class Catalog Number LLK3R400L LLK3R600L LLK3T400L LLK3T600L LLK3V400L LLK3V600L LLK3W400L LLK3W600L Model 586Trip Unit LG 600A Frame 3-Pole Electronic LCD Trip Unit Continuous Ampere Rating 400 600 400 600 400 600 N-Interrupting Class H-Interrupting Class Catalog Number Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER ELECTRONIC LSI TRIP NLK3A400L NLK3A600L HLK3A400L HLK3A600L ELECTRONIC LSIG TRIP NLK3G400L NLK3G600L HLK3G400L HLK3G600L ELECTRONIC LSI TRIP + GF ALARM ONLY NLK3K400L NLK3K600L HLK3K400L HLK3K600L L-Interrupting Class Catalog Number LLK3A400L LLK3A600L LLK3G400L LLK3G600L LLK3K400L LLK3K600L Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-191 Phase-out October 2022 VL Circuit Breakers Internal Accessories for JG 400A and LG 600A Frames Auxiliary Switch and Alarm Switch Combination Kits Description 1 Alarm Switch 1A/Bc Bases AMBL2 & AMBL3 2 Aux. Switches 1A + 1B Bases AMBL1 2 Aux. + 1 Alarm Switches 1A + 1B, 1A/B Bases AMBL2 & AMBL3 Mounting Pocketa Left, Rightb Left, Right Left, Rightb Catalog Number ASKL1 ASKL2 ASKL3 Auxiliary/Alarm Switch Mounting Base Only Description Up to 3 Auxiliary Switches 2 Aux. + 1 Alarm Switch 2 Aux. + 1 Alarm Switch Mounting Pocket Left, Right Left Pocket Only Right Pocket Only Catalog Number AMBL1 AMBL2 AMBL3 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Shunt Trips Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Mounting Pocket Right Pocket Only Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 24 VAC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC Mounting Pocket Right Pocket Only Catalog Number ASWPA ASWPB Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLL24 UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 Revised on 07/31/21 Selection UVRLN120 MOLDED CASE 7 CIRCUIT BREAKERS a Refer to the "Accessory Locations" chart on page 7-220 for guidelines and limitations about which pockets may be used for accessory combinations. b Includes 1A and 1B contact for alarm purposes, only one of which may be installed at any time. `A' refers to a normally open contact (open when the breaker contacts are open). `B' refers to a normally closed contact (closed when the breaker contacts are open). 7-192 Siemens Industry, Inc. SPEEDFAXTM Product Catalog External Accessories pages 7-207 through 7-219 Product Category MCCB VL Circuit Breakers MG 800A Frame, VL Series Selection/Dimensions Ordering Information Complete Assembled Breaker A complete factory assembled MG breaker includes the frame, trip unit, and standard line and load lugs, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to "X" for standard breakers. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to "Y". For special applications, refer to page 7-224. Mounting hardware is included with each frame or complete breaker. HACR rated. Interrupting Ratings RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) Interrupting Breaker 220/240 Class Type 240 480 600 250 500 ICU ICS 380/415 ICU ICS 690 ICU ICS N NMG 65 35 25 22 35 65 65 50 50 20 10 H HMG 100 65 35 25 50 100 75 70 70 30 15 L LMG 200 100 50 42 65 200 150 100 75 35 17 Connectors for 75°C Wire Construction Aluminum Aluminum Copper Aluminum Ampere Rating 200-800A 200-800A 200-800A 200-800A Wire Range 1/0500 kcmil Al/Cu 500-750 kcmil Al/Cu 1/0500 kcmil Cu #2600 kcmil Al/Cu No. of cables per connector 3 2 3 3 Catalog Number 3TA3MG500b 3TA2MG750b TC3MG500e 3TA3MG600bd a Standard connector supplied with complete breakers. b Kit consists of 3 terminal connectors. c Consists of one terminal. d Includes extended terminal cover. e Required for 100% rated MG breakers. Requires 90°C Cu cable sized at 75°C ampacity. Dimensions, inches (mm) Number To Handle of Poles Width Length Depth D1 2, 3 7.5 (190) 16 (406) 4.7 (119) 5.9 (151) Shipping Weight, lbs. (kg) Poles Frame Complete Trip Unit Breaker 2, 3 31.3 (14.2) 4.0 (1.8) 35.3 (16.0) MG Thermal-Magnetic, Instantaneous Trip Adjustment Range Instantaneous Trip Unit Continuous Overcurrent Setting (Ii) Amp Rating (In) Min. Max. 600 3000 6000 700 3250 6500 800 3250 6500 Note: Each breaker has 6 trip settings. MOLDED CASE 7 CIRCUIT BREAKERS Product Category MCCB External Accessories pages 7-207 through 7-219 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-193 VL Circuit Breakers MG 800A Thermal-Magnetic Trip Unit Selection Model 525Trip Unit MG 800A Frame 2-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 600 700 800 Catalog Number Catalog Number Catalog Number FRAME ONLY NMG2F800 HMG2F800 LMG2F800 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NMG2B600L NMG2B700L NMG2B800L HMG2B600L HMG2B700L HMG2B800L LMG2B600L LMG2B700L LMG2B800L MG 800A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 600 700 800 Catalog Number Catalog Number Catalog Number FRAME ONLY NMG3F800 HMG3F800 LMG3F800 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NMG3B600L NMG3B700L NMG3B800L HMG3B600L HMG3B700L HMG3B800L LMG3B600L LMG3B700L LMG3B800L Catalog Number TRIP UNIT ONLY CMT2B600 CMT2B700 CMT2B800 Catalog Number TRIP UNIT ONLY CMT3B600 CMT3B700 CMT3B800 MOLDED CASE 7 CIRCUIT BREAKERS 7-194 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB VL Circuit Breakers MG 800A Electronic Trip Units Selection Model 555Trip Units MG 800A Frame 3-Pole Electronic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 600 800 600 800 600 800 600 800 Catalog Number Catalog Number Catalog Number FRAME ONLY NMG3F800 HMG3F800 LMG3F800 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER ELECTRONIC LI TRIP NMG3R600L NMG3R800L NMG3T600L NMG3T800L NMG3V600L NMG3V800L NMG3W600L NMG3W800L HMG3R600L HMG3R800L ELECTRONIC LSI TRIP HMG3T600L HMG3T800L ELECTRONIC LSIG TRIP HMG3V600L HMG3V800L ELECTRONIC LIG TRIP HMG3W600L HMG3W800L LMG3R600L LMG3R800L LMG3T600L LMG3T800L LMG3V600L LMG3V800L LMG3W600L LMG3W800L Catalog Number TRIP UNIT ONLY CMT3R600 CMT3R800 CMT3T600 CMT3T800 CMT3V600 CMT3V800 CMT3W600 CMT3W800 MG 800A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class H-Interrupting Class Model 586Trip Unit L-Interrupting Class Continuous Ampere Rating 600 800 600 800 600 800 Catalog Number Catalog Number Catalog Number FRAME ONLY NMG3F800 HMG3F800 LMG3F800 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER LCD ELECTRONIC LSI TRIP NMG3A600L HMG3A600L LMG3A600L NMG3A800L HMG3A800L LMG3A800L LCD ELECTRONIC LSIG TRIP NMG3G600L NMG3G800L HMG3G600L HMG3G800L LMG3G600L LMG3G800L LCD ELECTRONIC LSI TRIP + GF ALARM ONLY NMG3K600L HMG3K600L LMG3K600L NMG3K800L HMG3K800L LMG3K800L Catalog Number TRIP UNIT ONLY CMT3A600 CMT3A800 CMT3G600 CMT3G800 CMT3K600 CMT3K800 MOLDED CASE 7 CIRCUIT BREAKERS Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-195 VL Circuit Breakers Internal Accessories for MG 800A, NG 1200A and PG 1600A Frames Auxiliary Switch and Alarm Switch Combination Kits Description 2 Aux. + 2 Alarm Switches 2A + 2B Bases AMBP2 4 Aux. Switches 2A + 2B Bases AMBP1 Mounting Pocketa Left Pocket Only Left, Right Catalog Number ASKP3 ASKP4 Auxiliary/Alarm Switch Mounting Base Only Description Up to 4 Auxiliary Switches 2 Aux. + 2 Alarm Switches Mounting Pocket Left, Right Left Pocket Only Catalog Number AMBP1 AMBP2 Auxiliary/Alarm Switch Only Common to DG - PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB Shunt Trips Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Mounting Pocket Right Pocket Only Catalog Number STRPB24DC STRPC60DC STRPD125DC STRPE250DC STRPM60 STRPN120 STRPS277 STRPV600 Undervoltage Release Description Mounting Pocket Catalog Number 12 VDC UVRPA12DC 24 VDC UVRPB24DC 48 VDC UVRPC48DC 60 VDC UVRPG60DC 110-127 VDC UVRPD125DC 220-250 VDC UVRPE250DC 110-127 VAC Right Pocket Only UVRPN120 220-240 VAC UVRPR240 208 VAC UVRPP208 277 VAC UVRPS277 380-415 VAC UVRPT415 440-480 VAC UVRPU480 a Refer to the "Accessory Locations" chart on page 7-220 for guidelines and limitations about which pockets may be used for accessory combinations. `A' refers to a normally open contact (open when the breaker contacts are open). `B' refers to a normally closed contact (closed when the breaker contacts are open). AMBP2 STRPN120 Selection x4 x4 MOLDED CASE 7 CIRCUIT BREAKERS 7-196 Siemens Industry, Inc. SPEEDFAXTM Product Catalog UVRPN120 External Accessories pages 7-207 through 7-219 Product Category MCCB VL Circuit Breakers NG 1200A Frame, VL Series Selection/Dimensions Ordering Information Complete Assembled Breaker with Lugs A complete factory assembled NG breaker includes the frame, trip unit, and standard line and load lugs, all factory installed and shipped as a complete breaker. Assembled breakers are available only with standard connectors. For any other configuration, order the frame, trip unit, and terminals as separate items. For DC applications, use thermal magnetic trip unit only. For reverse feed applications, select non-interchangeable trip breakers only. For non-interchangeable trip breakers, change the third digit of the catalog number to "X" for standard breakers. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to "Y". For special applications, refer to page 7-224. Mounting hardware is included with each frame or complete breaker. A Toggle Handle Extension is included with each frame or complete breaker. HACR rated. Interrupting Ratings Interrupting Class N H L Breaker Type NNG HNG LNG RMS Symmetrical Amperes (KA) UL 489 IEC 60947-2 Volts AC (50/60 Hz) Volts DC Volts AC (50/60 Hz) 220/240 380/415 690 240 480 600 250 500 ICU ICS ICU ICS ICU 65 35 25 22 35 65 35 50 25 20 100 65 35 25 50 100 50 70 35 30 200 100 65 42 65 200 100 100 50 35 ICS 10 15 17 Connectors for 75°C Wire Construction Ampere Rating Aluminum Aluminum Copper Aluminum 300-1200A 300-1200A 300-1200A 300-1200A Compression Lugs 300-1200A Wire Range 1/0500 kcmil Al/Cu 500-750 kcmil Al/Cu 1/0500 kcmil Cu 1/0500 kcmil Al/Cu 1/0-500 kcmil Al/Cu No. of cables per connector 4 3 4 4 -- a Total of 12 connectors (4 per phase Line or Load). b For 100% rated NG breakers. Requires 90°C Cu cable sized at 75°C ampacity. c Standard connector provided with complete breakers. d Kit consists of 3 terminal connectors. Catalog Number 3TA4NG500cd 3TA3NG750d 3TC4NG500bd 3TA4NG500Hbd 12CLN500 NG Thermal-Magnetic, Instantaneous Trip Adjustment Range Instantaneous Trip Unit Continuous Overcurrent Setting (Ii) Amp Rating (In) Min. Max. 800 4000 8000 900 5000 10000 1000 5000 10000 1200 7000 12000 Note: Each breaker has 6 trip settings. Dimensions, inches (mm) Number of Poles 2, 3 To Handle W L D D1 9 (229) 16 (406) 6 (152) 8.1 (207) Shipping Weight, lbs. (kg) Poles Frame Complete Trip Unit Breaker 2, 3 46.3 (21.0) 8.8 (4.0) 55.1 (25.0) MOLDED CASE 7 CIRCUIT BREAKERS Product Category MCCB External Accessories pages 7-207 through 7-219 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-197 VL Circuit Breakers NG 1200A Thermal-Magnetic Trip Unit Selection Ii AMPS 9000 10000 8000 11000 7000 12000 I n= 1200A 40 C TM ~ Trip Unit/Disparador 525 Ii AMPS 9000 10000 8000 11000 7000 12000 Amps Ii AMPS 9000 10000 8000 11000 7000 12000 Amps Model 525 Trip Unit NG 1200A Frame 2-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 800 900 1000 1200 Catalog Number Catalog Number Catalog Number FRAME ONLY NNG2F120 HNG2F120 LNG2F120 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NNG2B800L NNG2B900L NNG2B100L NNG2B120L HNG2B800L HNG2B900L HNG2B100L HNG2B120L LNG2B800L LNG2B900L LNG2B100L LNG2B120L NG 1200A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 800 900 1000 1200 Catalog Number Catalog Number Catalog Number FRAME ONLY NNG3F120 HNG3F120 LNG3F120 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NNG3B800L NNG3B900L NNG3B100L NNG3B120L HNG3B800L HNG3B900L HNG3B100L HNG3B120L LNG3B800L LNG3B900L LNG3B100L LNG3B120L Catalog Number TRIP UNIT ONLY CNT2B800 CNT2B900 CNT2B100 CNT2B120 Catalog Number TRIP UNIT ONLY CNT3B800 CNT3B900 CNT3B100 CNT3B120 MOLDED CASE 7 CIRCUIT BREAKERS 7-198 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB VL Circuit Breakers NG 1200A Electronic Trip Units Selection Model 555 Trip Units NG 1200A Frame 3-Pole Electronic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 800 1000 1200 800 1000 1200 800 1000 1200 800 1000 1200 Catalog Number Catalog Number Catalog Number FRAME ONLY NNG3F120 HNG3F120 LNG3F120 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NNG3R800L NNG3R100L NNG3R120L NNG3T800L NNG3T100L NNG3T120L NNG3V800L NNG3V100L NNG3V120L NNG3W800L NNG3W100L NNG3W120L ELECTRONIC LI TRIP HNG3R800L HNG3R100L HNG3R120L ELECTRONIC LSI TRIP HNG3T800L HNG3T100L HNG3T120L ELECTRONIC LSIG TRIP HNG3V800L HNG3V100L HNG3V120L ELECTRONIC LIG TRIP HNG3W800L HNG3W100L HNG3W120L LNG3R800L LNG3R100L LNG3R120L LNG3T800L LNG3T100L LNG3T120L LNG3V800L LNG3V100L LNG3V120L LNG3W800L LNG3W100L LNG3W120L Catalog Number TRIP UNIT ONLY CNT3R800 CNT3R100 CNT3R120 CNT3T800 CNT3T100 CNT3T120 CNT3V800 CNT3V100 CNT3V120 CNT3W800 CNT3W100 CNT3W120 MOLDED CASE 7 CIRCUIT BREAKERS NG 1200A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class H-Interrupting Class Model 586Trip Unit L-Interrupting Class Continuous Ampere Rating 800 1000 1200 800 1000 1200 800 1000 1200 Catalog Number Catalog Number Catalog Number FRAME ONLY NNG3F120 HNG3F120 LNG3F120 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NNG3A800L NNG3A100L NNG3A120L NNG3G800L NNG3G100L NNG3G120L NNG3K800L NNG3K100L NNG3K120L LCD ELECTRONIC LSI TRIP HNG3A800L HNG3A100L HNG3A120L LNG3A800L LNG3A100L LNG3A120L LCD ELECTRONIC LSIG TRIP HNG3G800L HNG3G100L HNG3G120L LNG3G800L LNG3G100L LNG3G120L LCD ELECTRONIC LSI TRIP + GF ALARM ONLY HNG3K800L LNG3K800L HNG3K100L LNG3K100L HNG3K120L LNG3K120L Catalog Number TRIP UNIT ONLY CNT3A800 CNT3A100 CNT3A120 CNT3G800 CNT3G100 CNT3G120 CNT3K800 CNT3K100 CNT3K120 Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-199 VL Circuit Breakers Internal Accessories for MG 800A, NG 1200A, and PG 1600A Frames Auxiliary Switch and Alarm Switch Combination Kits Description Mounting Pocketa Catalog Number 2 Aux. + 2 Alarm Switches 2A + 2B Base AMBP2 Left Pocket Only ASKP3 4 Aux. Switches 2A + 2B Base AMBP1 Left, Right ASKP4 Auxiliary/Alarm Switch Mounting Base Only Description Mounting Pocketa Catalog Number Up to 4 Auxiliary Switches 2 Aux. + 2 Alarm Switches Left, Right Left Pocket Only AMBP1 AMBP2 Auxiliary/Alarm Switch Only Common to DG-PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB Shunt Trips Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Mounting Pocket Right Pocket Only Catalog Number STRPB24DC STRPC60DC STRPD125DC STRPE250DC STRPM60 STRPN120 STRPS277 STRPV600 Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC Mounting Pocket Right Pocket Only Catalog Number UVRPA12DC UVRPB24DC UVRPC48DC UVRPG60DC UVRPD125DC UVRPE250DC UVRPN120 UVRPR240 UVRPP208 UVRPS277 UVRPT415 UVRPU480 a Refer to the "Accessory Locations" chart on page 7-220 for guidelines and limitations about which pockets may be used for accessory combinations. `A'refers to a normally open contact (open when the breaker contacts are open). `B'refers to a normally closed contact (closed when the breaker contacts are open). AMBP2 STRPN120 Selection x4 x4 MOLDED CASE 7 CIRCUIT BREAKERS 7-200 Siemens Industry, Inc. SPEEDFAXTM Product Catalog UVRPN120 External Accessories pages 7-207 through 7-219 Product Category MCCB VL Circuit Breakers PG 1600A Frame, VL Series & Thermal-Magnetic Trip Unit Selection/Dimensions Ordering Information A complete factory assembled PGbreaker includes the frame and trip unit only. The connectors must be ordered as separate items. PG thermal-magnetic breakers sold as non-interchangeable only. For any other configuration, order the frame, trip unit, and connectors as separate items. Connectors require a Breaker Lug Mounting Assembly or Breaker Mounting Base and must be ordered as a seperate item. For DC applications, use Thermal magnetic trip unit only. For reverse feed applications select non-interchangeable trip breakers only. Change the third digit of the catalog number to "X" for non-interchangeable trip breakers. For 100% rated breakers with a non-interchangeable trip unit, change the 3rd character of the catalog number to "Y". For special applications, refer to page 7-224. Mounting hardware is included with each frame or complete breaker. A Toggle Handle Extension is included with each frame or complete breaker. Interrupting Ratings Interrupting Class N H L Breaker Type NPG HPG LPG RMS Symmetrical Amperes (KA) UL 489 Volts AC (50/60 Hz) Volts DC 240 65 100 200 480 35 65 100 600 25 35 65 250 22 25 42 500 35 50 65 IEC 60947-2 (ETU only) Volts AC (50/60 Hz) 220/240 380/415 ICU ICS ICU ICS 65 35 50 25 100 50 70 35 200 100 100 50 690 ICU 20 30 35 ICS 10 15 17 Connectors for 75°C Wire Construction Aluminum Aluminum Aluminum Aluminum Copper Ampere Rating 1200-1600A 1200-1600A 1200-1600A 1200-1600A 1200-1600A Wire Range 1/0750 kcmil Al/Cu 300600 kcmil Al/Cu 600750 kcmil Al/Cu 300600 kcmil Al/Cu 300600 kcmil Cu No. of cables per phase 6 5 4 6 5 Catalog Number 3TA6PG750ac TA5P600bd TA4P750bd TA6R600bd TC5R600bde Dimensions, inches (mm) Number of Poles 2, 3 To Handle W L D D1 9 (229) 16 (406) 6 (152) 8.1 (207) Shipping Weight, lbs. (kg) Poles Frame Trip Unit Complete Breaker 2, 3 60.2 (27.3) 8.8 (4.0) 69.0 (31.3) PG Thermal-Magnetic, Instantaneous Trip Adjustment Range Instantaneous Trip Unit Continuous Overcurrent Setting (Ii) Amp Rating (In) Min. Max. 1200 7000 12000 1400 7000 12000 1600 7000 12000 Note: Each breaker has 6 trip settings in this range. Mounting Arrangement Description Lug Mounting Assembly Breaker Mounting Base (Front Connect) Breaker Mounting Base (Rear Connect) Catalog Number LMAP1600 MBPG1600 MBPG1601 Ii AMPS 9000 10000 8000 11000 7000 12000 In = 1600A 40º C TM ~ Trip Unit/Disparador 525 Ii AMPS 9000 10000 8000 11000 7000 12000 Amps Model 525Trip Unit Ii AMPS 9000 10000 8000 11000 7000 12000 Amps PG 1600A Frame 3-Pole with Thermal-Magnetic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 1200 1400 1600 Catalog Number Catalog Number Catalog Number COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NPX3B120 NPX3B140 NPX3B160 HPX3B120 HPX3B140 HPX3B160 LPX3B120 LPX3B140 LPX3B160 MOLDED CASE 7 CIRCUIT BREAKERS a Requires Lug Mounting Assembly LMAP1600. b Requires Breaker Mounting Base MBPG1600 Kit or MBPG1601. c Consists of 3 connectors. Product Category MCCB d Consists of 1 connector. e Required for 100% rated PG breakers. Requires 90°C cable sized at 75°C ampacity. IEC 60947-2: ONLY applies to Electronic Trip Units (ETUs). External Accessories pages 7-207 through 7-219 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-201 VL Circuit Breakers PG 1600A Electronic Trip Units Selection Model 555Trip Unit PG 1600A Frame 3-Pole Electronic Trip Unit N-Interrupting Class H-Interrupting Class L-Interrupting Class Continuous Ampere Rating 1200 1600 1200 1600 1200 1600 1200 1600 Catalog Number Catalog Number Catalog Number FRAME ONLY NPG3F160 HPG3F160 LPG3F160 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NPG3R120 NPG3R160 NPG3T120 NPG3T160 NPG3V120 NPG3V160 NPG3W120 NPG3W160 ELECTRONIC LI TRIP HPG3R120 HPG3R160 ELECTRONIC LSI TRIP HPG3T120 HPG3T160 ELECTRONIC LSIG TRIP HPG3V120 HPG3V160 ELECTRONIC LIG TRIP HPG3W120 HPG3W160 LPG3R120 LPG3R160 LPG3T120 LPG3T160 LPG3V120 LPG3V160 LPG3W120 LPG3W160 Catalog Number TRIP UNIT ONLY CPT3R120 CPT3R160 CPT3T120 CPT3T160 CPT3V120 CPT3V160 CPT3W120 CPT3W160 PG 1600A Frame 3-Pole Electronic LCD Trip Unit N-Interrupting Class H-Interrupting Class Model 586Trip Unit L-Interrupting Class Continuous Ampere Rating 1200 1600 1200 1600 1200 1600 Catalog Number Catalog Number Catalog Number FRAME ONLY NPG3F160 HPG3F160 LPG3F160 COMPLETE FACTORY ASSEMBLED CIRCUIT BREAKER NPG3A120 NPG3A160 NPG3G120 NPG3G160 NPG3K120 NPG3K160 LCD ELECTRONIC LSI TRIP HPG3A120 LPG3A120 HPG3A160 LPG3A160 LCD ELECTRONIC LSIG TRIP HPG3G120 LPG3G120 HPG3G160 LPG3G160 LCD ELECTRONIC LSI TRIP + GF ALARM ONLY HPG3K120 HPG3K160 LPG3K120 LPG3K160 Catalog Number TRIP UNIT ONLY CPT3A120 CPT3A160 CPT3G120 CPT3G160 CPT3K120 CPT3K160 MOLDED CASE 7 CIRCUIT BREAKERS 7-202 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB VL Circuit Breakers Internal Accessories for MG 800A, NG 1200A, and PG 1600A Frames Auxiliary Switch and Alarm Switch Combination Kits Description Mounting Pocketa Catalog Number 2 Aux. + 2 Alarm Switches 2A + 2B Base AMBP2 4 Aux. Switches 2A + 2B Base AMBP1 Left Pocket Only Left, Right ASKP3 ASKP4 Auxiliary/Alarm Switch Mounting Base Only Description Mounting Pocketa Catalog Number Up to 4 Auxiliary Switches 2 Aux. + 2 Alarm Switches Left, Right Left Pocket Only AMBP1 AMBP2 Auxiliary/Alarm Switch Only Common to DG-PG Frames Description 1 Normally Open Contact (1A) 1 Normally Closed Contact (1B) Catalog Number ASWPA ASWPB Shunt Trips Description 24 VDC 48-60 VDC 110-127 VDC 220-250 VDC 48-60 VAC 110-127 VAC 208-277 VAC 380-600 VAC Mounting Pocket Right Pocket Only Catalog Number STRPB24DC STRPC60DC STRPD125DC STRPE250DC STRPM60 STRPN120 STRPS277 STRPV600 Undervoltage Release Description 12 VDC 24 VDC 48 VDC 60 VDC 110-127 VDC 220-250 VDC 110-127 VAC 220-240 VAC 208 VAC 277 VAC 380-415 VAC 440-480 VAC Mounting Pocket Right Pocket Only Catalog Number UVRPA12DC UVRPB24DC UVRPC48DC UVRPG60DC UVRPD125DC UVRPE250DC UVRPN120 UVRPR240 UVRPP208 UVRPS277 UVRPT415 UVRPU480 a Refer to the "Accessory Locations" chart on page 7-220 for guidelines and limitations about which pockets may be used for accessory combinations. `A'refers to a normally open contact (open when the breaker contacts are open). `B'refers to a normally closed contact (closed when the breaker contacts are open). AMBP2 STRPN120 UVRPN120 Selection x4 x4 MOLDED CASE 7 CIRCUIT BREAKERS Product Category MCCB External Accessories pages 7-207 through 7-219 Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-203 VL Circuit Breakers Molded Case Switch General Typically a molded case switch is used when a compact load-break switch is needed for disconnect purposes. The VL line of molded case switches from Siemens is made of the same materials and components as the VL circuit breakers but do not provide overcurrent protection. Each molded case switch has a fixed instantaneous selfprotecting trip element which may open the switch under high fault conditions. Application Note Overcurrent protection must be provided by an appropriate overcurrent protective device located upstream from Selection the molded case switch. Also, the short-circuit current rating of the switch is limited to the interrupting rating of the upstream protective device or the ratings in the table below, whichever is less. Ordering Information Each type VL molded case switch accepts the same terminals and accessories as the equivalent VL circuit breakers. All type VL molded case switches are suitable for reverse feed applications. Mounting hardware and standard line and load terminals are included on ratings through 250A. For 400 1600A ratings, order the lugs separately. All ratings are UL listed and CSA certified. Molded Case Switch Maximum Ampere Rating / Frame 150A / DG 250A / FG 400A / JG 600A / LG 800A / MG 1200A / NG 2-Pole Catalog Number HDR2S150 HFR2S250 HJS2S400 HLR2S600 HMS2S800 HNS2S120 1600A / PG -- Maximum Ampere Rating / Frame 250A / FG 400A / JG 600A / LG 800A / MG 1200A / NG 1600A / PG 3-Pole Catalog Number LFR3S250 LJS3S400 LLR3S600 LMS3S800 LNS3S120 LPS3S160 3-Pole Catalog Number HDR3S150 HFR3S250 HJS3S400 HLR3S600 HMS3S800 HNS3S120 HPS3S160 Short-Circuit Current Rating 240V 100k 100k 100k 100k 100k 100k 480V 65k 65k 65k 65k 65k 65k 600V 20k 20k 25k 18k 35k 35k 100k 65k 35k Self Protective Instantaneous Override 2,500A 3,500A 4,400A 5,500A 6,500A 12,000A 14,000A Short-Circuit Current Rating 240V 200k 200k 200k 200k 200k 200k 480V 100k 100k 100k 100k 100k 100k 600V 25k 25k 18k 65k 65k 65k Self Protective Instantaneous Override 3,500A 4,400A 5,500A 6,500A 12,000A 14,000A MOLDED CASE 7 CIRCUIT BREAKERS The Short-Circuit Current Rating is the maximum available current of the circuit where the switch is used, when protected by an appropriate overcurrent protective device. 7-204 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB VL Circuit Breakers Motor Circuit Protectors Selection General Protection of Motor Circuits Molded case circuit breakers are used in motor circuits as a disconnecting means and for short-circuit protection. They should be used in conjunction with motor-running, over-current protection devices, and should permit the motor to start without nuisance tripping from motor-inrush current. The circuit breaker should have a continuous current rating of not less than 115% of the motor fullload current. The recommended motor circuit protectors listed have continuous-current ratings of at least 115% of motor full-load currents. The trip setting positions are approximately 11 times motor full-load current. The suggested trip settings may need to be adjusted upward to no higher than 1300% of full-load current for non-design E type motors, and no greater than 1700% of full-load current for design E motors, to allow for motor startup due to in-rush current. Breaker Mounted Immediately Ahead of Motor Starter Siemens motor circuit protectors are recommended for use in combination motor starters to provide selective short-circuit protection for the motor branch circuit. The adjustable instantaneous trip feature of the Siemens motor circuit protector provides for a trip setting slightly above the peak motor in-rush current. With this setting, no delay is introduced in opening the circuit when a fault occurs. This circuit breaker has no time-delay trip element. Therefore it must be used in conjunction with, and immediately ahead of, the motor-running overcurrent protection device. Important: The information below does not apply to all motor applications: it is recommended that the user refer to the National Electrical Code (NEC) for specific needs. MOLDED CASE 7 CIRCUIT BREAKERS Table 1 (When Breaker is Mounted Immediately Ahead of Motor Starter) 3-Phase Induction Type Motors (Siemens motor circuit protectors for branch circuit use with alternating-current combination, full voltage motor starters) Motor Full Load Amperes 35-50 42-60 48-70 55-80 62-90 69-100 58-83 69-100 81-117 92-133 104-150 115-150b 96-139 115-150b 135-150b 135-150b 135-150b 135-150b 46-67 55-80 65-93 74-107 83-120 92-133 77-111 92-133 108-156 123-178 138-200 154-222 135-194 162-210 188-220 215-241 242-250b 242-250b Trip Setting (A) 450 540 630 720 810 900 750 900 1050 1200 1350 1500 1250 1500 1750 2000 2250 2500 600 720 840 960 1080 1200 1000 1200 1400 1600 1800 2000 1750 2100 2450 2800 3150 3500 Catalog Number a HDP3L150L HDP3M150L HDP3H150L HFP3L250L HFP3M250L HFP3H250L a M otor circuit protectors rated 150A and 250A are supplied with line and load lugs installed. If lugs are required on 400A to 1200A motor circuit breakers, order required lugs separately. Motor Full Load Amperes 96-139 115-167 135-194 154-222 173-250 192-278 154-222 185-267 215-311 246-356 277-400 308-400b 154-222 185-267 215-311 246-356 277-400 308-444 212-306 254-367 296-428 338-489 381-550 423-600 250-361 292-422 335-483 385-556 442-638 500-722 385-556 462-667 538-778 615-889 692-1000 769-1111 Trip Setting (A) 1250 1500 1750 2000 2250 2500 2000 2400 2800 3200 3600 4000 2000 2400 2800 3200 3600 4000 2750 3300 3850 4400 4950 5500 3250 3800 4350 5000 5740 6500 5000 6000 7000 8000 9000 10,000 Catalog Number a HJM3L400 HJM3M400 HLM3J600 HLM3Y600 HMM3M800 HNM3M120 b T hese settings are provided for starting currents greater than 11X but not to exceed 17X. Full Load Amps ( FLA ) not to exceed ampere rating of MCP. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-205 VL Circuit Breakers Revised on 10/31/18 600 Volt DC Circuit Breakers General Siemens UL Listed non-interchangeable trip DC Thermal/magnetic Molded Case Circuit Breakers shown below are for use in grounded & ungrounded general DC circuits and ungrounded battery supply circuits of UPS systems. These breakers are rated at 600Vdc closed circuit and feature rated interruption levels from 42,000 to 65,000 amperes as indicated in the table. This family of circuit breakers is rated from 100 to 1600 Amperes. Types HFGD through HPGD circuit breakers are provided with an adjustable magnetic over-current function located on the face of the circuit breaker. Contact Siemens for specific magnetic over-current values. To properly use these UL Listed circuit breakers at 600Vdc and the indicated Selection interruption level, it is necessary to connect the terminals of the 3 pole circuit breaker in a series configuration as shown in the diagram below. Types HFGD through HPGD use the same internal and external accessories as the standard FG through PG frames and associated types. Consult the individual frame section for accessory information. Frame FG JG LG MG NG PG Type HFGD HJGD HLGD HMGD HNGD HPGD Continuous Ampere Rating 100 150 175 200 250 250 300 350 400 400 500 600 600 700 800 800 900 1000 1200 1200 1400 1600 Catalog Number (3-pole)a HFC3B100 HFC3B150 HFC3B175 HFC3B200 HFC3B250 HJC3B250 HJC3B300 HJC3B350 HJC3B400 HLC3B400 HLC3B500 HLC3B600 HMC3B600 HMC3B700 HMC3B800 HNC3B800 HNC3B900 HNC3B100 HNC3B120 HPC3B120 HPC3B140 HPC3B160 Short-Circuit Current Rating 600VDCb 42K 42K 42K 42K 42K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K 65K + LOAD MOLDED CASE 7 CIRCUIT BREAKERS a T erminal connectors must be ordered separately; see page 7-214. b S tandard VL breakers DG - PG feature DC ratings up to 500V for ungrounded UPS applications. Consult the individual frame section for more information. 7-206 Siemens Industry, Inc. SPEEDFAXTM Product Catalog External Accessories Selection MOLDED CASE 7 CIRCUIT BREAKERS 1 Base for Plug-In or Draw-Out 9 Cover Frame for Door Cutout 17 Thermal Magnetic Trip Unit (525) 2 Interphase Barriers 10 Stored Energy Operator 18 Electronic Trip Unit (555) 3 Rear Terminals Flat and Round 11 Rotary Handle Operator 19 Elec. Trip Unit with LCD (586) 4 Bus Extensions 12 Variable Depth Rotary Operator 20 Communication Module with ZSI 5 Terminal Connectors 13 Max Flex Operator 21 Electronic Trip Unit Tester and 6 Plug-In Terminal Blades 14 Circuit Breaker LCD Power Supply 7 Extended Terminal Shield 15 Shunt Trip or Undervoltage Releases 8 Standard Terminal Shield 16 Auxiliary/Alarm Switches Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-207 External Accessories Operating Mechanisms RHFF RHVF12 RHVFBM RHVM3RH RHVMS12 Description Through-Door Rotary Handle Operator Kit Fixed depth and the handle is mounted directly on the circuit breaker. Lockable knob (for up to 3 padlocks). NEMA 1, 12 Red Handle Version with red knob, yellow indicator plate NEMA 1, 12 Door-Mounted Rotary Handle Operator Kit Variable depth, door mounted handle. Includes knob with masking frame, indicator plate, detachable door coupling, 12" shaft, and breaker mounted rotary operator. Lockable knob (for up to 3 padlocks). NEMA 1, 12 For DG to FG Frame 150 to 250 A Catalog Number RHFF RHFFEM RHVF12 Auxiliary Switch Kits For Direct or Extended Rotary Handle Operators (RHF and RHV). Form C, Early Break type2 Aux. Switch Kit a Includes 1 switch with 5' wire For Door-Mounted Operator -- -- For Through-Door Operator RHSFA1F Includes 2 switches with 5' wire For Door-Mounted Operator -- -- For Through-Door Operator RHSFA2F Door-Mounted Rotary Operator Mechanism Breaker mechanism only RHVFBM Door-Mounted Rotary Handle Only Standard version NEMA 1, 12 NEMA 3R NEMA 4X Red Handle version RHVM12H RHVM3RH RHVM4XH RHVMEMH NFPA-79 Handle Kit Intermediate handle for NFPA-79 compliance with door-mounted rotary operator RHVF79H Extension Shaft Only, for Door Mounted Operator 2 inches (50.8mm) 3 inches (76.2mm) 12 inches (304.8 mm) 16 inches (406.4 mm) 24 inches (609.6mm) w/ support bracket RHVMS02 -- -- RHVMS12 RHVMS16 RHVMS24 For JG to LG Frame 400 A to 600 A Catalog Number RHFL RHFLEM RHVL12 RHSLA1 RHSLA1F RHSLA2 RHSLA2F RHVLBM RHVM12H RHVM3RH RHVM4XH RHVMEMH RHVM79H RHVMS02 -- -- RHVMS12 RHVMS16 RHVMS24 RHVM12H MOLDED CASE 7 CIRCUIT BREAKERS a During manual operation, Early Break auxiliary switch contacts open before the breaker opens. 7-208 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Description Through-Door Rotary Handle Operator Kit Fixed depth, breaker mounted. For direct fitting to the circuit breaker. Lockable with up to 3 padlocks. NEMA 1, 12 Red Handle version with red knob, yellow indicator plate NEMA 1, 12 Door-Mounted Rotary Handle Operator Kit Variable depth, door mounted handle. Includes knob with masking frame, indicator plate, detachable door coupling, 12" shaft, and breaker mounted rotary operator. Lockable knob (for up to 3 padlocks). NEMA 1, 12 For MG Frame 800 A Catalog Number -- -- -- -- RHVM12 Auxiliary Switch Kits For Direct or Extended Rotary Handle Operators (RHF and RHV). Early Break type2 Aux. Switch Kit Includes 1 switch with 5' wire For Door-Mounted Operator RHSMA1 For Through-Door Operator -- -- Includes 2 switches with 5' wire For Door-Mounted Operator RHSMA2 For Through-Door Operator -- -- Door-Mounted Rotary Operator Mechanism Breaker mechanism only RHVMBM Door-Mounted Rotary Handle Only Standard version NEMA 1, 12 NEMA 3R NEMA 4X Red Handle version RHVM12H RHVM3RH RHVM4XH RHVMEMH NFPA-79 Handle Kit Intermediate handle for NFPA-79 compliance with door-mounted rotary operator RHVM79H Extension Shaft Only, for Door Mounted Operator 2 inches (50.8mm) 3 inches (76.2mm) 12 inches (304.8 mm) 16 inches (406.4 mm) 24 inches (609.6mm) w/ support bracket RHVMS02 -- -- RHVMS12 RHVMS16 RHVMS24 For NG to PG Frame 1200 to 1600 A Catalog Number -- -- -- -- -- -- RHSPA1 -- -- RHSPA2 -- -- RHVPBM RHVP3RH RHVP3RH RHVP4XH RHVPEMH RHVP79H -- -- RHVPS03 RHVPS12 -- -- RHVPS24 MOLDED CASE 7 CIRCUIT BREAKERS Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-209 External Accessories Operating Mechanisms Description Variable Depth Flange Mounted Operator Kit Adjustable from 8" to 16" Complete kit, includes handle and variable depth operator. NEMA 1, 3R, 12 IEC Black Handle NEMA 4X NEMA 1, 3R, 12 NEMA 4X For DG and FG Frame 150 to 250 A Catalog Number FHVF3R FHVF4X FHVF3RB FHVF4XB Max-FlexTM, Variable Depth Flange Mounted Operator Kit Complete kit, includes plastic handle, breaker operator, and cable. NEMA 1, 3R, 12 For DG and FG operators, the cable is 36", all others are 48" May be right- or left-hand mounted Handle Only, for Max-FlexTM Variable Depth NEMA 1, 3R, 12 Plastic NEMA 1, 3R, 12 Steel - epoxy coated NEMA 4, 4X Steel - chrome plated Solid color (all gray) Plastica NEMA 1, 3R, 12 Solid color (black handle) Steel epoxy coateda NEMA 1, 3R, 12 Breaker Operator Mechanism Only, for Max-FlexTM MFKF3R MFHM3R MFHM3RS MFHM4X MFHM3RB MFHM3RSB MFMF Cable Only, for Max-FlexTM Variable Depth 36" 48" 60" 72" 84" 96" 120" 144" Handle Auxiliary Switch Form C (1NO - 1NC), early breakb 1 Aux. switch 2 Aux. switch MFCF036 MFCF048 MFCF060 MFCF072 MFCF084 MFCF096 MFCF120 MFCF144 MFSFA1 MFSFA2 For JG and LG Frame 400 to 600 A Catalog Number FHVL3R FHVL4X FHVL3RB FHVL4XB MFKL3R MFHM3R MFHM3RS MFHM4X MFHM3RB MFHM3RSB MFML MFCM036 MFCM048 MFCM060 MFCM072 MFCM084 MFCM096 MFCM120 MFCM144 MFSLA1 MFSLA2 MOLDED CASE 7 CIRCUIT BREAKERS a Max-FlexTM handles are available with solid gray or black handles instead of the customary "Red for On" flange handle. The black handle is preferred for IEC markets, where red handles have a specific meaning. b During manual operation, Early Break aux. contacts open before the breaker opens. 7-210 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Description Variable Depth Flange Mounted Operator Kit Adjustable from 8" to 16" Complete kit, includes handle and variable depth operator. NEMA 1, 3R, 12 IEC Black Handle NEMA 4X NEMA 1, 3R, 12 NEMA 4X Max-FlexTM, Variable Depth Flange Mounted Operator Kit Complete kit, includes plastic handle, breaker operator, and cable. NEMA 1, 3R, 12 For DG and FG operators, the cable is 36", all others are 48" May be right- or left-hand mounted Handle Only, for Max-FlexTM Variable Depth NEMA 1, 3R, 12 Plastic NEMA 1, 3R, 12 Steel - epoxy coated NEMA 4, 4X Steel - chrome plated Solid color (all gray) Plastica NEMA 1, 3R, 12 Solid color (black handle) Steel epoxy coateda NEMA 1, 3R, 12 Breaker Operator Mechanism Only, for Max-FlexTM Cable Only, for Max-FlexTM Variable Depth 36" 48" 60" 72" 84" 96" 120" 144" Handle Auxiliary Switch Form C (1NO - 1NC), early breakb 1 Aux. switch 2 Aux. switch For MG Frame 800 A Catalog Number -- -- -- -- MFKM3R MFHM3R MFHM3RS MFHM4X MFHM3RB MFHM3RSB MFMM MFCM036 MFCM048 MFCM060 MFCM072 MFCM084 MFCM096 MFCM120 MFCM144 MFSPA1 MFSPA2 For NG Frame 1200 A Catalog Number -- -- -- -- MFKP3RS For PG Frame 1600 A Catalog Number MFKP3RS -- MFHP3RS MFHP4X -- MFHP3RSB MFMP -- MFCP048 MFCP060 MFCP072 -- MFCP096 MFCP120 MFCP144 MFSPA1 MFSPA2 -- MFHP3RS MFHP4X -- MFHP3RSB MFMP -- MFCP048 MFCP060 MFCP072 -- MFCP096 MFCP120 MFCP144 MFSPA1 MFSPA2 MOLDED CASE 7 CIRCUIT BREAKERS a Max-FlexTM handles are available with solid gray or black handles instead of the customary "Red for On" flange handle. The black handle is preferred for IEC markets, where red handles have a specific meaning. b During manual operation, Early Break aux. contacts open before the breaker opens. Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-211 External Accessories Revised on 11/30/19 Operating Mechanisms Description Stored Energy and Motor Operators Lockable with up to 3 padlocks. AC Voltage DC Voltage -- 24 42-48 60 110127 42-48 60 110127 220250 220250 Cylinder Locks for Field Installation For DG to FG Frame 150 to 250 A Catalog Number Stored Energy Type SEAFB SEAFM SEAFY SEAFN SEAFR CLKF MOLDED CASE 7 CIRCUIT BREAKERS Connections Standard 3-Pole Set Terminal Shields Description Front Bus Bar Connections Includes nut keeper plates and shield. Standard (straight) 3-Pole Set Bus Bar Connection Strap Kit Includes 6 - Bus Bars, 6 Nut Keepers & Shields 100% rated applications Terminal Shields Includes 2 terminal shields. 3-Pole Standard Shield 3-Pole Extended Shield Interphase Barriers Set of 2 barriers Also fits plug-in and draw-out bases. Lug Mounting Assy. Breaker Mounting Base Front connected Rear connected For DG Frame 150 A Catalog Number FBCD3 -- -- TSSF3 TSLF3 IPBF -- -- -- For FG Frame 250 A Catalog Number FBCF3 -- -- TSSF3 TSLF3 IPBF -- -- -- IPBF 7-212 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB For JG to LG Frame 400 to 600 A Catalog Number Stored Energy Type SEALB SEALM SEALY SEALN SEALR CLKP Revised on 11/30/19 For MG Frame 800 A Catalog Number Stored Energy Type SEAMB SEAMM SEAMY SEAMN SEAMR CLKP For NG to PG Frame 1200 to 1600 A Catalog Number Motor Operator Type MTRPB MTRPM MTRPY MTRPN MTRPR CLKP MOLDED CASE 7 CIRCUIT BREAKERS For JG Frame 400 A Catalog Number FBCJ3 -- TSSL3 TSLL3 IPBM -- -- -- For LG Frame 600 A Catalog Number FBCL3 -- -- -- IPBM -- -- -- For MG Frame 800 A Catalog Number FBCM3 -- TSSM3 TSLM3 IPBM -- -- -- For NG Frame 1200 A Catalog Number SSBP SSBPH TSSP3 TSLP3 IPBP -- -- -- For PG Frame 1600 A Catalog Number SSBP SSBPH TSSP3 TSLP3 IPBP LMAP1600b MBPG1600 MBPG1601 a Not for use with standard Al terminals. Use Standard Shield for rear connection and Extended Shield for busbar connection. Product Category MCCB b Kit includes connection for one side of breaker only. Order quantity 2 if connecting line and load side. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-213 External Accessories Connections For DG Frame 150 A For FG Frame 250 A Description Nut Keeper Plates For ring/tongue terminal or bus bar connections. (For metric threads on other than the JG frame, change "TNK" to "TMK") 1 Nut Keeper Plate Kit of 3 Catalog Number TNKD TNKD3 Catalog Number TNKF TNKF3 TNKD3 3TA2LG600LD 3TA4NG500 Mechanical Lugs Steel Wrap Around Body (Cu Wire Only) Cable Size; (cables per phase) Single Lug Kit of 3 Aluminum Body (Al or Cu Wire) Cable Size; (cables per phase) Single Lug Kit of 2 Kit of 3 Cable Size; (cables per phase) Single Lug Kit of 2 Kit of 3 Cable Size; (cables per phase) Single Lug Copper Body (Cu Wire Only) Cable Size; (cables per phase) Single Lug Kit of 2 Kit of 3 Cable Size; (cables per phase) Single Lug Compression Lugs Cable Size; (cables per phase) Kit of 2 Kit of 3 Cable Size; (cables per phase) Kit of 2 Kit of 3 Cable Size; (cables per phase) Kit of 3 D istribution Lugs (Cu Wire Only) Cable Size; (cables per phase) Single Lug Kit of 3 Cable Size; (cables per phase) Single Lug Kit of 3 Note: pictures provide graphical representaions only. Control Wire Terminals Control Wire Terminal (Single) Control Wire Terminal (Kit of 3) #8-1/0; 1-hole TW1DG20 3TW1DG20 #6-3/0; 1-hole TA1DG30 -- 3TA1DG30 -- -- -- -- -- -- -- #6-3/0; 1-hole TC1DG30 -- 3TC1DG30 -- -- #14-2/0; 1-cable 2CLD20 3CLD20 -- -- -- #14-#2; 3-hole TA3DG02 3TA3DG02 #14-#4; 6-hole TA6DG04 3TA6DG04 -- -- #4-350 kcmil; 1-hole TW1FG350 3TW1FG350 #4-350 kcmil; 1-hole TAW1FG350 -- 3TAW1FG350 -- -- -- -- -- -- -- #4-350 kcmil; 1-hole TCW1FG350 -- 3TCW1FG350 -- -- #4-350 kcmil; 1-cable -- 3CLF350 -- -- -- -- -- #14-#1; 2-hole and #14-2/0; 1-hole TA3FG20 3TA3FG20 #14-#4; 6-hole TA6FG04 3TA6FG04 -- -- MOLDED CASE 7 CIRCUIT BREAKERS Required for 100% rated breakers. Requires 90°C cable sized at 75°C ampacity. 7-214 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB For JG Frame 400 A Catalog Number TMKJ TMKJ3 metric only For LG Frame 600 A Catalog Number TNKL TNKL3 For MG Frame 800 A Catalog Number TNKM TNKM3 For NG Frame 1200 A Catalog Number TNKP TNKP3 For PG Frame 1600 A Catalog Number TNKP TNKP3 MOLDED CASE 7 CIRCUIT BREAKERS 1/0-600 kcmil; 1-hole TW1JG600 3TW1JG600 3/0-250 kcmil; 2-hole TA2JG250 -- 3TA2JG250 AL: 250-750 kcmil CU: 3/0-600 kcmil; 1-hole TA1JG750 -- 3TA1JG750 -- -- -- 3/0-250 kcmil; 2-hole TC2JG250 -- -- 3/0-750 kcmil; 1-hole TC1JG750 -- -- -- #2-600 kcmil; 2-hole -- -- -- 3TA2LG600LDa 3TA2LG600LNb AL: 250-750 kcmil CU: 3/0-600 kcmil; 1-hole TA1JG750 (400A max) -- 3TA1JG750 (400A max) -- -- -- #2-600 kcmil; 2-hole -- -- -- 3TC2LG600LD 3TC2LG600LN -- -- -- -- -- 1/0-500 kcmil, 3-hole TA3MG500 3TA3MG500 500 -750 kcmil; 2-hole TA2MG750 -- 3TA2MG750 #2-600 kcmil; 3-hole -- 3TA3MG600d (Kit of 3) 1/0-500 kcmil; 3-hole TC3MG500 -- -- -- -- #6-350 kcmil; 1-cable #6-350 kcmil; 2-cable -- -- -- 3CLJ350 6CLL350 (kit of 6) -- 250-600 kcmil; 1-cable 250-750 kcmil; 1-cable -- 3CLJ600 3CLL750 -- -- -- -- 250-600 kcmil; 2-cable 6CLL600 (kit of 6) -- -- -- -- #14-#4; 12-hole -- -- TA12JG04 -- -- 3TA12JG04 -- -- #14-2/0; 6-hole -- -- TA6JG20 -- -- 3TA6JG20 -- -- -- -- -- 1/0-500 kcmil; 4-hole -- 2TA4NG500 3TA4NG500 3TA4NG500Hc 500 -750 kcmil; 3-hole -- 2TA3NG750 3TA3NG750 -- 1/0-500 kcmil; 4-hole -- -- 3TC4NG500 -- -- 1/0-500 kcmil; 4-cable -- 12CLN500 (kit of 12) -- -- -- -- -- -- -- -- -- -- -- -- -- -- 1/0-750 kcmil; 6-hole -- -- 3TA6PG750e 600-750 kcmil; 4-hole TA4P750f -- 300-600 kcmil; 5; 6-hole TA5P600f TA6R600f -- -- -- -- -- 300-600 kcmil; 5-hole TC5R600f -- -- -- -- -- -- -- -- -- -- -- -- -- -- TA2JG250PT -- TA3MG500PT -- -- -- 3TA2LG600LNPT -- 3TA4NG500PT -- All lug kits include the nut keepers. a Mounted on Load Side Only. b Mounted on Line Side Only. Product Category MCCB c Required for 100% rated breakers. Requires 90°C cable sized at 75°C ampacity. d Requires extended modified shield. e Used only with LMAP1600 mounting base. f Used only with MBPG1600 or MBPG1601 mounting base. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-215 External Accessories Revised on 11/30/19 General Handle Padlocking Device Cable Interlock System Description Handle Padlocking Device To padlock breaker toggle in the "OFF" position. Accepts up to 3 padlocks with 58 mm shackles. For DG Frame 150 A Catalog Number HPLF Handle Blocking Device For holding the handle in the "ON" position. Not a lockout/tagout device. HBDF Cable Interlock Mechanism Provides mechanical interlocking between 2 circuit-breakers includes operator mechanism for one circuit breaker only. Combination with the next larger or smaller frame size is possible. Interlock Cable Cable only, to connect 2 circuit breakers. Cable length 18 in. .46m (recommended up to 250A) Cable length 36 in. .91m (recommended from 400800A) Cable length 54 in. 1.37m (recommended from 12001600A) CBTF CBCF18 CBCM36 CBCP54 Mounting Screw Kit Includes the necessary hardware to mount a circuit breaker to the user's prepared surface Kit with 2 screws (SAE thread) Kit with 4 screws (SAE thread) Trip Adjustment Sealing Cover Includes a trip unit cover to prevent tampering or adjustment of trip settings. Seal not included. MSKF2 MSKF4 3VL97008BL00 For FG Frame 250 A Catalog Number HPLF HBDF CBTF CBCF18 CBCM36 CBCP54 MSKF2 MSKF4 3VL97008BL00 MOLDED CASE 7 CIRCUIT BREAKERS 7-216 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB Revised on 11/30/19 For JG Frame 400 A Catalog Number HPLL HBDL For LG Frame 600 A Catalog Number HPLL HBDL For MG Frame 800 A Catalog Number HPLM HBDM For NG Frame 1200 A Catalog Number HPLP HBDP For PG Frame 1600 A Catalog Number HPLP HBDP CBTL -- CBCM36 CBCP54 -- MSKL4 3VL97008BL00 CBTL -- CBCM36 CBCP54 -- MSKL4 3VL97008BL00 CBTM -- CBCM36 CBCP54 -- MSKM4 3VL97008BL00 CBTP -- -- CBCP54 -- MSKP4 3VL97008BL00 CBTP -- -- CBCP54 -- MSKP4 3VL97008BL00 MOLDED CASE 7 CIRCUIT BREAKERS Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-217 External Accessories Revised on 10/31/18 Ground Sensors & Electronic Accessories NGSF150 NGSM600 Description Neutral Current Transformer (Ground Sensor, N-pole) Neutral = 35/60A Neutral = 100A Neutral = 150A Neutral = 250A Neutral = 400A Neutral = 600A Neutral = 800A Neutral = 1000/1200A Neutral = 1600A For DG Frame 150 A Catalog Number NGSD060 NGSF100 NGSF150 -- -- -- -- -- -- For FG Frame 250 A Catalog Number -- NGSF100 NGSF150 NGSJ250 -- -- -- -- -- Spare Flat Cable Power Stick Communications & Electronics Power Stick - Hand held, battery operated power supply for LCD trip units. (Requires two 9V batteries.) Trip testing for both 555 & 586 trip units. Spare flat cable for Power Stick. COM20 Profibus Communications Module with ZSI for electronic trip units (order cable separately) COM21 Modbus Communications Module with ZSI for electronic trip units (order cable separately) Cable for COM20/21, 1.5 m (4.9 ft) Com20 Profibus & Com21 Modbus Communications Module Cable for COM20/21, 3.0 m (9.8 ft) Addressing Plug - assigns a field bus address without a PC by plugging into COM20/21 Door Cutouts & Extensions Cover Frame for Door Cutout THEL Cover Frame for Door Cutout For fixed or plug-in mounted circuit breakers. (IP30) 2-Pole & 3-Pole For breakers with stored energy operator. (IP40) Circuit-breaker draw-out mounted and toggle handle operated. Kit includes cover frame (bezel) and escutcheon as needed. (IP40) (not for use with rotary handle or stored energy operator) Toggle Handle Extension For spare or replacement. (One is included with each NG - PG frame.) EPSP18V COMPCA COMPRO20 COMMOD21 COMKIT3 COMKIT6 3UF79100AA000 BZLF3 BZLFRHSE BZLFBDC -- EPSP18V COMPCA COMPRO20 COMMOD21 COMKIT3 COMKIT6 3UF79100AA000 BZLF3 BZLFRHSE BZLFBDC -- MOLDED CASE 7 CIRCUIT BREAKERS THEP 7-218 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Product Category MCCB For JG Frame 400 A Catalog Number -- -- -- NGSJ250 NGSL400 -- -- -- -- For LG Frame 600 A Catalog Number -- -- -- -- NGSL400 NGSM600 -- -- -- For MG Frame 800 A Catalog Number -- -- -- -- -- NGSM600 NGSN800 -- -- Revised on 11/30/19 For NG Frame 1200 A Catalog Number -- -- -- -- -- -- NGSN800 NGSP120 -- For PG Frame 1600 A Catalog Number -- -- -- -- -- -- -- NGSP120 NGSP160 EPSP18V COMPCA COMPRO20 COMMOD21 COMKIT4 COMKIT7 3UF79100AA000 EPSP18V COMPCA COMPRO20 COMMOD21 COMKIT4 COMKIT7 3UF79100AA000 EPSP18V COMPCA COMPRO20 COMMOD21 COMKIT5 COMKIT8 3UF79100AA000 EPSP18V COMPCA COMPRO20 COMMOD21 COMKIT5 COMKIT8 3UF79100AA000 EPSP18V COMPCA COMPRO20 COMMOD21 COMKIT5 COMKIT8 3UF79100AA000 MOLDED CASE 7 CIRCUIT BREAKERS BZLL3 BZLLRHSE BZLLBDC THEL BZLL3 BZLLRHSE BZLLBDC THEL BZLM3 BZLMRHSE THEM BZLP3 BZLPRHSE THEP BZLP3 BZLPRHSE THEP Product Category MCCB Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-219 VL Circuit Breakers Accessory Locations Selection MOLDED CASE 7 CIRCUIT BREAKERS Locations of Internally Mounted Accessories Frame Family Left Pocket DG*, FG*, JG, LG 150 to 600A Up to 3 Auxiliary Switches Up to 2 Auxiliary Switches + 1 Alarm Swich Right Pocket Shunt Trip or UVR or up to 3 Auxiliary Switches or up to 2 Auxiliary Switches + 1 Alarm Switch Shunt Trip or UVR or up to 3 Auxiliary Switches or up to 2 Auxiliary Switches + 1 Alarm Switch MG, NG, PG 800 to 1600A Up to 4 Auxiliary Switches Up to 2 Auxiliary Switches + 2 Alarm Swiches Shunt Trip or UVR or up to 4 Auxiliary Switches Shunt Trip or UVR or up to 4 Auxiliary Switches * Except DG and FG breakers with Electronic Trip Units. Due to the location of the Magnetic Latch, the Left Pocket is not available for accessories. Accessory Information b Aux. Switch is an Auxiliary Switch, 1A or 1B contact b Alarm Switch has 1A or 1B contact b UVR is an Undervoltage Release bThe standard location for factory mounted Auxiliary and Alarm Switches is the Left Pocket Accessory Maximums DG, FG, JG, LG Maximum Accessories: b Maximum of six (6) switches total bDG, FG Maximum of two (2) Alarm Switches, one each in the Left and Right Pockets. JG, LG Max. of 1 Alarm, Left only MG, NG, PG Maximum Accessories: bMaximum of eight (8) switches total bMaximum of two (2) Alarm Switches, Left Pocket only For applications using COMMOD20 and COMMOD21 for communication using Modbus or Profibus DG, FG COMKIT3 & COMKIT6 provide auxiliary contact kit. May add only one or two contact blocks for Alarm or Auxiliary function. JG, LG COMKIT4 & COMKIT7 provide auxiliary contact kit mounted in left pole pocket. One contact block can be added for Auxiliary function. Right pole pocket available for other release or an additional Auxiliary contact kit. MG, NG, PG COMKIT5 & COMKIT8 provide auxiliary contact kit mounted in Left pole pocket. Two contact blocks can be added for Auxiliary function and one for Alarm function. Right pole pocket available for other release or an additional Auxiliary Contact kit. 7-220 Siemens Industry, Inc. SPEEDFAXTM Product Catalog VL Circuit Breakers Suffix for factory mounted Switch Combinations If the frame is: DG, FG, JG or LG DG, FG, JG or LG DG, FG, JG or LG MG, NG or PG MG, NG or PG And you need these functions: 1 Alarm Switch 1 NO Alarm 1 NC Alarm 2 Aux. Switches 1 NO + 1 NC Aux. Contacts 2 Aux. + 1 Alarm Switches 1NO + 1NC Aux. and 1NC Alarm 2NO Aux. and 1NC Alarm 2 Aux. + 2 Alarm Switches 1NO + 1NC Aux. and 1NO + 1NC Alarm 2NO Aux. and 2NC Alarm 2NC Aux. and 2NO Alarm 4 Aux. Switches 2NO + 2NC Aux. Suffix for factory mounted Shunt Trips If the frame is: DG, FG, JG or LG MG, NG or PG And you need these functions: 24V DC 48-60V DC 110-127V DC 220-250V DC 48-60V AC 110-127V AC 208-277V AC 380-600V AC 24V DC 48-60V DC 110-127V DC 220-250V DC 48-60V AC 110-127V AC 208-277V AC 380-600V AC Suffix for factory mounted Undervoltage Releases If the frame is: DG, FG, JG or LG MG, NG or PG And you need these functions: 12V DC 24V DC 48V DC 60V DC 110-127V DC 220-250V DC 24V AC 110-127V AC 220-240V AC 208V AC 277V AC 380-415V AC 440-480V AC 12V DC 24V DC 48V DC 60V DC 110-127V DC 220-250V DC 110-127V AC 220-240V AC 208V AC 277V AC 380-415V AC 440-480V AC Then add this suffix: A1 A2 A3 A3 A4 Then add this suffix: RB RC RD RE RM RN RS RV RB RC RD RE RM RN RS RV Then add this suffix: UA UB UC UG UD UE UK UN UR UP US UT UU UA UB UC UG UD UE UN UR UP US UT UU Selection Device Catalog Number ASKL1 ASKL2 ASKL3 ASKP3 ASKP4 Device Catalog Number STRLB24DC STRLC60DC STRLD125DC STRLE250DC STRLM60 STRLN120 STRLS277 STRLV600 STRPB24DC STRPC60DC STRPD125DC STRPE250DC STRPM60 STRPN120 STRPS277 STRPV600 Device Catalog Number UVRLA12DC UVRLB24DC UVRLC48DC UVRLG60DC UVRLD125DC UVRLE250DC UVRLL24 UVRLN120 UVRLR240 UVRLP208 UVRLS277 UVRLT415 UVRLU480 UVRPA12DC UVRPB24DC UVRPC48DC UVRPG60DC UVRPD125DC UVRPE250DC UVRPN120 UVRPR240 UVRPP208 UVRPS277 UVRPT415 UVRPU480 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-221 Technical Data DG Max rated continuous current Rated operational voltage NEMA IEC 150 V AC 600 VAC 690 Rated Impulse Withstand Voltage Main conducting paths Auxiliary circuits kV 8 kV 4 Ambient Temperature Range ºC High Ambient Derating(thermal-mag.) 50ºC 60ºC 70ºC -25 to +75 93% 86% 80% Operating Cycles Max switching rate (per hour) 20,000 120 Power loss (at max. rated current) Thermal-magnetic W 15 48 Electronic trip unit W 40 IEC 1 Time constant t = 10 ms 1 current path 2 current paths 3 current paths in series in series Up to 250V DC 440V DC 600V DC -- NEMA Time constant t = 8 ms 2 poles switching 1 current path 250V DC Max. 2 30 3 poles switching 2 current paths in series 500V DC Max. 2 18 Accessories Auxiliary / Alarm Switch Current rating (1 or 2 switches) 10 Current rating (3 or 4 same switch) A 5 Shunt Trip Pick-up voltage V 0.7 1.1 Power Consumption (short-time) at: 48 60 V AC VA 110 127 V AC VA 208 277 VAC VA 380 600 V AC VA 24 V DC W 48 60 V DC W 110 127 VDC W 220 250 V DC W Max. Operating time ms 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50 FG 250 600 690 8 4 -25 to +75 93% 86% 80% 20,000 120 32 80 60 -- 30 25 10 5 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50 JG LG 400 600 600 600 690 690 8 4 -25 to +75 93% 86% 80% 20,000 120 8 4 -25 to +75 93% 86% 80% 10,000 60 60 175 85 230 90 160 -- -- 30 30 35 35 10 10 5 5 0.7 1.1 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50 MG 800 600 690 8 4 -25 to +75 95% 86% 80% 5,000 60 170 250 250 -- 42 65 10 5 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50 NG 1200 PG 1600 600 600 690 690 8 4 -25 to +75 95% 86% 80% 3,000 30 8 4 -25 to +75 95% 80% 74% 3,000 30 150 220 200 260 210 260 -- -- 42 42 65 65 10 10 5 5 0.7 1.1 0.7 1.1 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50 401 501 424 489 533 736 408 645 594 740 925 559 648 722 820 50 1 Consult Siemens for short circuit values. 2 Review individual frame and type values. MOLDED CASE 7 CIRCUIT BREAKERS 7-222 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Technical Data Revised on 05/31/18 DG FG JG LG MG NG PG Undervoltage Trip Drop voltage (percentage) V Pick-up voltage (percentage) V Power consumption (continuous) at: 110 127 V AC VA 220 250 VAC VA 208 VAC VA 277 VAC VA 380 415 VAC VA 440 480 VAC VA 500 525 VAC VA 600 VAC VA Max. opening time ms 35% 70% 35% 70% 35% 70% 35% 70% 35% 70% 35% 70% 35% 70% 70% 85% 70% 85% 70% 85% 70% 85% 70% 85% 70% 85% 70% 85% 1 1 1 1 1.1 1.1 1.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.9 1.9 1.9 1.9 1.9 1.9 1.9 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.8 2.8 2.8 2.8 2.8 2.8 2.8 50 50 50 50 50 50 50 Motorized Operating Mechanism Motor with stored energy mechanism (synchronizable) Motor Operator Max. switching rate (per hour) Command duration Closing time Charging time Break time Power consumption Inrush (A) Control Voltages 110 127 VAC 220 250 VAC 24 VDC 48 VDC 60 VDC ms ms s s VA/W X 120 20 50 <100 <5 <5 <100 X 120 20 50 <100 <5 <5 <100 X 120 20 50 <100 <5 <5 <200 X 60 20 50 <100 <5 <5 <250 X 60 20 50 <100 <5 <5 <250 X 30 -- <5,000 <5 <5 X 30 -- <5,000 <5 <5 Operating Range 85 110% of rated control voltage MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-223 Technical Data Unusual Operating Conditions Revised on 11/30/17 Reference Note: The information provided on this and the next page is intended for reference and recommendation only. Because several variables can act on a circuit breaker's performance at the same time, the data below is based less on controlled testing, than on experience and engineering judgment. Contact Siemens for further information on special conditions and treatment. High Ambient Temperatures Because thermal-magnetic trip breakers are temperature sensitive and calibrated for a specific ambient of 40° C (104° F) (average enclosure temperature), a higher ambient will cause the breaker to trip at lower current than its nameplate rating, in other words, causing the breaker to "derate" (see Table 1). Similarly, the current carrying capacity of a circuit conductor is based upon a certain ambient temperature, a higher ambient will reduce its current carrying capacity, causing it to "derate." Thus, with a fluctuating temperature, a thermal-magnetic breaker will derate nearly parallel with its connected circuit conductors and maintain close circuit protection. If the application temperature exceeds 40° C (104° F) and is known, either a breaker specially calibrated for the higher ambient or one oversized according to Table 1 may be selected. In a case such as this, the circuit conductors should be oversized as well. Siemens Electronic Trip Unit Breakers are insensitive to temperature changes. However, they do include circuitry to protect the components from abnormally high temperatures. Altitude Reduced air density at altitudes greater than 6600 ft. (2000 meters) affects the ability of a molded case circuit breaker to transfer heat and interrupt faults. Therefore, circuit breakers applied at these altitudes should have interrupting, insulation and continuous currents derated as indicated in Figure 1. Table 1 Temperature derating data for thermal-magnetic breakers Reference Ampere Rating at 40° C (104° F) 50 60 70 90 100 125 150 175 200 225 250 300 350 400 500 600 700 800 900 1000 1200 1400 1600 Ampere Rating at: 50°C (122° F) 60° C (140° F) 46 42 56 52 65 60 84 78 94 87 114 100 136 120 159 140 182 160 205 180 235 220 276 252 325 301 372 340 468 435 564 525 658 613 754 704 828 749 900 1090 1304 825 1000 1148 1500 1320 Siemens Breaker Frames DG FG JG LG MG NG PG Figure 1 Altitude adjustment MOLDED CASE 7 CIRCUIT BREAKERS 7-224 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Technical Data Unusual Operating Conditions Unusual Operating Conditions 400 Hz Systems Circuit Breaker Derating Required This table lists the maximum continuous current carrying capacity for Siemens breakers at 400Hz. Due to the increased resistance of the copper sections resulting from the skin effect produced by eddy currents at these frequencies, circuit breakers in many cases require derating. The thermal derating on these devices is based upon 100%, three phase application in open air in a maximum of 40°C (104° F) with 48 in. (1219 mm) of the specified cable or bus at the line and load side. Additional derating of not less than 20% will be required if the circuit breaker is to be utilized in an enclosure. Further derating may be required if the enclosure ambient temperature exceeds 40°C(104° F). Cable and Bus Sizing The cable and bus sizes to be utilized at 400Hz are not based on standard National Electric Codes tables for 60Hz application. Larger cross sections are necessary at 400Hz. All bus bars specified are based upon mounting the bars in the vertical plane to allow maximum air flow. All bus bars are spaced at a minimum of 0.25 in. (6 mm) apart. Mounting of bus bars in the horizontal plane will necessitate additional drafting. Edgewise orientation of the bus may change the maximum ratings indicated. If additional information is required for other connections of cable or bus, contact Siemens for information. Reference Application Recommendations It is recommended that temperatures be measured on the line and load terminals or T-connectors of the center pole. These are usually the hottest terminals with a balanced load. A maximum temperature of 75°C (35°C over a maximum ambient of 40°C) would verify the particular application. Temperature profiles taken on these breakers can be correlated to ensure that the hottest points within the breaker are within the required temperature limits. Interrupting Rating Circuit breakers used in 400 Hz systems are limited to a 5000 A interrupting rating. If higher ratings are required, consult Siemens. Breaker type DG FG JG JG 100% Rated LG Maximum continuous ampere rating at 40°C (104°F) 60HZ 400HZ 75°C (167F) Copper cable per pole Enclosed after No of Open air Open air derating pieces Wire size 50 48 60 57 70 63 80 72 90 80 100 90 110 95 125 105 150 125 100 90 110 95 125 105 38 1 #8 46 1 #6 50 1 #4 58 1 #4 64 1 #3 72 1 #3 75 1 #2 84 1 #1 100 1 #1/0 72 1 #3 75 1 #2 84 1 #1 150 125 100 1 #1/0 175 140 112 1 #2/0 200 160 128 1 #3/0 225 180 144 1 #4/0 250 200 160 1 250 kcmil 250 210 168 1 250 kcmil 300 240 192 1 350 kcmil 350 260 208 1 500 kcmil 400 300 240 2 #2/0 250 210 210 1 250 kcmil 300 240 240 1 350 kcmil 350 260 260 1 500 kcmil 400 300 300 2 #3/0 400 300 240 2 #3/0 500 375 300 2 250 kcmil 600 420 336 2 350 kcmil Breaker type LG MG MG 100% Rated NG NG 100% Rated PG PG 100% Rated Maximum continuous ampere rating at 40°C (104°F) 60HZ 400HZ 75°C (167F) Copper cable per pole Enclosed after No of Open air Open air derating pieces Wire size 400 300 500 375 600 420 600 430 240 2 #3/0 300 2 250 kcmil 336 2 350 kcmil 360 2 350 kcmil 700 500 400 3 250 kcmil 800 560 448 3 300 kcmil 600 430 430 2 350 kcmil 700 500 800 560 800 560 900 600 1000 650 1200 780 900 600 500 3 250 kcmil 560 3 300 kcmil 448 3 300 kcmil 480 3 350 kcmil 520 3 400 kcmil 624 4 350 kcmil 600 3 350 kcmil 1000 650 650 3 400 kcmil 1200 780 780 4 350 kcmil 1200 780 624 4 400 kcmil 1400 850 1600 960 1200 780 680 4 500 kcmil 768 5 500 kcmil 780 4 400 kcmil 1400 850 850 4 500 kcmil 1600 960 960 5 500 kcmil The information provided on this page is intended for reference and recommendation only. Because several variables can act on a circuit breaker's performance at the same time, the data above is based less on controlled testing, than on experience and engineering judgment.Contact Siemens for further information on special conditions and treatment. Additional derating may be required if the ambient temperature is greater than 40°C (104°F). Calculated after derating to compensate for the heating of the copper conductor, caused by the skin effect generated by eddy currents produced at 400/415HZ. MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-225 Molded Case Circuit Breakers Revised on 03/25/17 Series Connected Short Circuit Ratings General The term "Series Connected Short Circuit Rating" refers to the application of series circuit breakers in a combination that allows downstream breakers to have lower individual interrupting ratings than the available fault current. This is permitted as long as the series combination has been tested and certified by UL. The tables on these pages list specific main and branch breaker combinations that may be used for the short circuit interrupting ratings shown. No substitutions are permitted. All combinations shown have been tested and are UL Listed. This information is provided as a reference tool only. For verification of specific combination ratings consult the UL Recognized Components Directory. 240V Breaker Series Ratings Series Rating kAIR 22000 42000 65000 Main Breaker Type Max. Amperes QPH, BQH, BLH 70 (1P) 125 (2P) 100 (3P) QPMH 200 (2P) QJH2 225 (2P, 3P) QPPH 225 (2P) QRH2 250 (2, 3P) QJ2H 225 (2, 3P) HQP, HBQ, HBL 70 (1P) 125 (2P) 100 (3P) Branch Breaker Type QP, BQ, BL QE, BLE, QPF, BLF QE, BLE, BE, QPF, BQF, BLF QPF2, BLF2 QT QG, BG, BLG BAF, QAF, QAF2, BAF2, QFGA2, BFGA2 BAF, QAF QP QE, QPF QAF, BAF QT QP, BQ, BL QPF, BQF, BLF, BG, BLG QE, BE, BLE, QPF2, BLF2 QPF, BLF, BG, BLG, QE BE, BLE BAF, QAF, QAF2, BAF2 BAF, QAF QT QR2 QP, BQ, BL QE, BLE, BE, QPF, BQF, BLF, QPF2, BLF2 QE, BLE, BE, QPF, BLF BAF, QAF, QAF2, BAF2 BAF, QAF QPP QT QP,BQ,BL QG, BG, BLG QT QFGA2, BFGA2, QAF2, BAF2, QAF, BAF QAF, BAF QPF2, BLF2, QPF, BQF, BLF, QE, BLE, BE QPF, BLF, QE, BLE QN, QNR QS QR2 QP, BQ, BL QPH, BQH, BLH QR2, QRH2 QJH2 QP, BQ, BL, QPH, BQH, BLH QPF, BQF, BLF, BE, QPHF, BQHF, BLHF, QEH, BLEH, QE, BLE, QPF2, BLF2, QPHF2, BLHF2, QPHF2, BLHF2 QEH, BLEH, QE, QPHF, BLHF, BLE, QPF, BLF QT QG, BG, BLG Number of Poles Voltage Amperes 1 120/240 15-70 2 240 15-125 3 240 15-100 2 120/240 15-60 1 240 15-30 1, 2 120/240 15-40 1, 2 120/240 15-30 1 120 15-20 2 120/240 15-20 1 120 15-25 120/240 35-70 2 120/240 15-25 35-125 1 2 120/240 15-30 15-60 1 120 15-20 2 120/240 15-20 2 120/240 15-30 1 120/240 15-70 2 240 15-125 3 240 60-100 1 120 15-30 2 120/240 15-60 1 120 15-20 2 120/240 15-20 1, 2 120/240 15, 20, 40 2,3 240 100-225 1 120/240 15-70 2 120/240 15-125 1 120 15-30 2 120/240 15-60 1 120 15-20 2 120/240 15-20 2 120/240 125-200 1, 2 120/240 15-40 1 120/240 15-70 2 120/240 15-125 2 240 15-125 3 240 15-100 1 120 15-30 2 120/240 15-30 1,2 120/240 15-50 1 120 15-20 2 120/240 15-20 1 120 15-30 2 120/240 15-60 2 120/240 150-200 2 120/240 100-225 2 120/240 100-250 1 120/240 15-70 2 120/240 15-125 3 240 60-100 1 120/240 15-70 2 120/240 15-125 3 240 15-100 2,3 240 100-225 2, 3 240 60-225 1 120/240 15-70 2 240 15-125 3 240 15-100 1 120 15-30 2 120/240 15-60 1, 2 120/240 15-40 1, 2 120/240 15-30 240V Breaker Series Ratings (continued) Series Rating kAIR 65000 (cont.) Main Breaker Branch Breaker Type Max. Amperes Type Number of Poles Voltage Amperes BAF, QAF, BQAF, QAF2, HQP, HBQ, HBL 70 (1P) BAF2, QAFH2, BAFH2, 125 (2P) QFGA2, BFGA2, QF100 (3P) GAH2, BFGAH2 1 BAF, QAF 2 120 15-20 120/240 15-20 ED4, ED4, ED6 100 (1P) 125 (2P, 3P) QP, BQ, BL QPH, BQH, BLH 1 2 3 QPHF, BQHF, BLHF, QPF, BQF, BLF, QE, QEH, BLEH, BE, BLE, QPF2, BLF2, 1 QPHF2, BLHF2 QEH, BLEH, QE, QPHF, BLHF,BLE, QPF, BLF 2 QAF2, BAF2, BAF, QAF, BQAF, QAFH2, BAFH2, QAFH, BQAFH, BAFH, 1 QFGA2, BFGA2, QF- GAH2, BFGAH2 QAF, BAF, QAFH, BAFH 2 120/240 15-70 240 15-125 240 15-100 120 15-30 120/240 15-60 120 15-20 120/240 15-20 ED2 1,2,3 120/240 15-100 QT 1,2 120/240 15-40 NDGA, NDGB 150 (2P, 3P) QPH, BQH, BLH 1 120/240 15-70 2 240 15-125 3 240 15-100 HQPP QP, BQ, BL, 1 QPH, BQH, BLH 2 QPF, BQF, BLF, QPHF, BQHF, BLHF, QEH, BLEH, QE, BLE, BE, BLF2, QPF2, 1 QFGA2, BFGA2 225 QEH, BLEH, QE, QPHF, BLHF, BLE, QPF, BLF 2 (2P) BAF, QAF, BQAF, QAF2, BAF2, QAFH2, BAFH2, QAFH, BQAFH, QFGAH2, 1 BFGAH2 BAF, QAF, QAFH, BAFH 2 120/240 15-70 120/240 15-125 120/240 15-30 120/240 15-60 120 15-20 120/240 15-20 QT 1, 2 120 15-40 QPPH, QPP 2 120/240 125-200 QP, BQ, BL QPH, BQH, BLH 1 120/240 15-70 2 120/240 15-125 3 240 15-100 QPF, QPHF, BLF, BLHF 1,2 120/240 15-60 QPF2, BLF2, QPHF2, 1 BLHF2 2 120 15-30 120/240 15-60 FD6-A, FXD6-A QAF, BAF, QAF2, BAF2, BQAF, QAFH2, BAFH2, QAFH, BQAFH, BAFH, 1 QFGA2, BFGA2, QFGAH2, BFGAH2 QAF, BAF, QAFH, BAFH 2 120 15-20 120/240 15-20 QR2, QRH2 2,3 240 100-225 QJ2H, QJ2, QJH2 2,3 240 60-225 QPPH 2 120/240 125-225 NFGA, NFGB 250 (2P,3P) QPH, BQH, BLH QR2, QRH2 1 120/240 15-70 2 120/240 15-125 3 240 15-100 2,3 240 100-250 QP, BQ, BL 1 120/240 15-70 2 120/240 15-125 3 240 15-100 HQR2 QT 1,2 QFGA2, BFGA2, QAF2, BAF2, QAF, BAF 1 QAF, BAF 2 QPF2, BLF2, QPF, BQF, BLF, QE, BLE, BE 1 QPF, BLF, QE, BLE 2 120/240 15-50 120 15-20 120/240 15-20 120 15-30 120/240 15-60 QPH, BQH, BLH 1 120/240 15-70 2 120/240 15-125 3 240 15-100 MOLDED CASE 7 CIRCUIT BREAKERS 7-226 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Series Connected Short Circuit Ratings Revised on 02/06/18 General 240V Breaker Series Ratings (continued) Series Rating kAIR 65000 (cont.) Main Breaker Type Max. Amperes HQR2 (cont.) 250 (2P, 3P) JXD2-A, JD6-A JXD6-A NJGA/ NJJA 400 (2P, 3P) SJD6-A SJD6-B HJD6-A, HJXD6 LD6-A LXD6-A NLGA, NLGB 600 (2P, 3P) SLD6-A SLD6-B Branch Breaker Type QFGAH2, BFGAH2, QAFH2, BAFH2, QAFH, BAFH QAFH, BAFH QPHF, BLHF, QPHF2, BLHF2, QEH, BLEH QEH, BLEH, QPHF, BLHF QN, QNH, QNR, QNRH QS, QSH, QSHH QR2, QRH2 QPH, BQH, BLH QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 QR2, QRH2 QJ2H, QJH2 QPH, BQH, BLH QR2, QRH2 QN, QNH QNR, QNRH QPH, BQH, BLH QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 QR2, QRH2 QPH QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 QPH, BQH, BLH QR2, QRH2 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 QJ2H, QJH2 QPH, BQH, BLH QR2, QRH2 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 QN, QNH QNR, QNRH QPH, BQH, BLH QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 QR2, QRH2 QPH Number of Poles 1 2 1 2 2 2 2,3 1 2 3 1 1 2,3 2,3 1 2 3 2,3 2 2 1 2 3 1 1 2,3 1 2 3 1 1 1 2 3 2,3 1 1 2,3 1 2 3 2,3 1 1 2 2 1 2 3 1 1 2,3 1 2 3 Voltage Amperes 120 15-20 120/240 15-20 120 15-30 120/240 15-60 120/240 150-200 120/240 100-225 240 100-250 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 240 100-250 240 60-225 120/240 15-70 120/240 15-125 240 15-100 240 100-250 120/240 150-200 120/240 150-200 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 240 100-250 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 120/240 15-70 120/240 15-125 240 15-100 240 100-250 120 15-20 120 15-30 240 60-225 120/240 15-70 120/240 15-125 240 15-100 240 100-250 120 15-20 120 15-30 120/240 150-200 120/240 150-200 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 240 100-250 120/240 15-70 120/240 15-125 240 15-100 HLD6-A, HLXD6-A MD6, MXD6 800 (2P, 3P) QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 1 1 QPH, BQH, BLH 2 3 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 1 QR2, QRH2 2,3 120 15-20 120 15-30 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 240 100-250 240V Breaker Series Ratings (continued) Series Rating kAIR 65000 (cont.) Main Breaker Type Max. Amperes NMG, HMG SMD6 SMD6-B 800 (2P, 3P) (cont.) HMXD6 HMD6 ND6, NXD NNG, HNG 1200 (2P, 3P) SND6 SND6-B HND6, HNXD6 SPD6, SPD6-B, PD6, PXD6 NPG 1600 (2P, 3P) HPD6, HPXD6 HRD6, HRXD6 2000 (2P, 3P) RD6, RXD6 Branch Breaker Type Number of Poles Voltage Amperes 1 QPH, BQH, BLH 2 3 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 1 QR2, QRH2 2,3 QN, QNH 2 QNR, QNRH 2 1 QPH, BQH, BLH 2 3 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 1 QR2, QRH2 2,3 1 QPH 2 3 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 1 1 QPH, BQH, BLH 2 3 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 1 QR2, QRH2 2,3 1 QPH, BQH, BLH 2 3 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 1 QR2, QRH2 2,3 QN, QNH 2 QNR, QNRH 2 1 QPH, BQH, BLH 2 3 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 1 QR2, QRH2 2,3 1 QPH 2 3 QAF2, BAF2, QAFH2, BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 QPF2, BLF2, QPHF2, BLHF2 1 1 QPH, BQH, BLH 2 3 QR2, QRH2 2,3 1 QPH, BQH, BLH 2 3 QR2, QRH2 2,3 QN, QNH 2 QNR, QNRH 2 1 QPH 2 3 1 QPH 2 3 QR2, QRH2 2,3 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 240 100-250 120/240 150-200 120/240 150-200 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 240 100-250 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 240 100-250 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 240 100-250 120/240 150-200 120/240 150-200 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 240 100-250 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120 15-30 120/240 15-70 120/240 15-125 240 15-100 240 100-250 120/240 15-70 120/240 15-125 240 15-100 240 100-250 120/240 150-200 120/240 150-200 120/240 15-70 120/240 15-125 240 15-100 120/240 15-70 120/240 15-125 240 15-100 240 100-250 QPH, BQH, BLH 1 120/240 15-70 2 120/240 15-125 3 240 15-100 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-227 Molded Case Circuit Breakers Series Connected Short Circuit Ratings 240V Breaker Series Ratings (continued) Series Rating kAIR 100000 Main Breaker Type Max. Amperes HED4 100 (1P) HED4, HED6 125 (2P, 3P) NGB, HGB, LBG NGB, HGB, LBG HDGA, HDGB 150 (2P, 3P) HQPPH 225 (2P) HQJ2H 225 (2P, 3P) Branch Breaker Type ED2, ED4 QP, BQ, BL, QPH, BQH, BLH, HQP, HBQ, HBL, QAF2, BAF2, QAF, BQAF, BAF, QAFH2, BAFH2, HQAF2, HBAF2, QAFH, BQAFH, BAFH, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QAF, BAF, QAFH, BAFH QEH,BLEH, QE, BE, QPHF,BQHF, BLHF, QPF, BLF, BQF, BLE, QPF2, BLF2, QPHF2, BLHF2, HQPF2, HBLF2 QEH, BLEH, QPHF, QE, BLHF,QPF,BLF, BLE ED2 ED4 ED4, ED6 QT QAF2, QAFH2, QAF, BQAF, BAF, BAFH2, HQAF2, HBAF2, QAFH, BQAFH, BAFH, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QAF, BAF, QAFH, BAFH QPF,BQF,BLF, QPHF, BQHF, BLHF, QPF2, BLF2, QPHF2, BLHF2, HQPF2, HBLF2 QPF, BLF QP, BQ, BL, QPH, BQH, BLH, HQP, HBQ,HBL ED4, ED6 ED4, ED6 NDGA, NDGB QP, BQ, BL, QPH, BQH, BLH, HQP, HBQ, HBL HQPP, QPPH, QPP QAF2, BAF2, QAF, BQAF, BAF, QAFH2, BAFH2, HQAF2, HBAF2, QAFH, BQAFH, BAFH, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QAF, BAF, QAFH, BAFH QEH, BLEH, QE, BE, QPHF, BQHF, BLHF, QPF, BQF, BLF, BLE, QPF2, BLF2, QPFH2, BLHF2, HQPF2, HBLF2 QE, QEH, BLEH, QPHF,BLHF,QPF,BLF,BLE QR2, QRH2, HQR2 QT QP, BP, QL QR2, QRH2, HQR2 QPH, BQH, BLH, HQP, HBQ ,HBL QAF2, BAF2, QAF, BQAF, BAF, QAFH2, BAFH2, HQAF2, HBAF2, QAFH, BQAFH, BAFH, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QAF, BAF, QAFH, QAFH QEH, BLEH, QE, BE, QPHF, BQHF, BLHF, QPF, BQF, BLF, BLE, QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 QEH, BLEH, QPHF, BLE, BLHF, QE, QPF, BLF QT Number of Poles Voltage Amperes 1 120 15-100 1 120/240 15-70 2 240 15-125 3 240 15-100 1 120 15-20 2 120/240 15-20 1 120 15-30 2 1,2,3 1 2,3 1,2 120/240 15-60 120/240 15-100 120 15-100 240 15-125 120/240 15-40 1 120 15-20 2 120/240 15-20 1 120 15-30 2 120/240 15-60 1 120 15-70 2 120/240 15-125 3 240 15-100 1 240 15-100 2,3 240 15-125 2,3 240 50-150 1 120/240 15-70 2 120/240 15-125 2 120/240 125-225 1 120 15-20 2 120/240 15-20 1 120 15-30 2 120/240 15-60 2 120/240 100-225 1,2 120/240 15-40 1 120/240 15-25 35-70 2 120/240 15-25 35-125 3 240 15-100 2,3 240 100-225 1 120/240 15-70 2 120/240 15-125 3 240 15-100 1 120 15-20 2 120/240 15-20 1 120 15-30 2 120/240 15-60 1 120/240 15-50 Revised on 03/25/17 General 240V Breaker Series Ratings (continued) Series Rating kAIR 100000 (cont.) Main Breaker Type Max. Amperes HFD6, HFXD6 HFGA, HFGB 250 (2P, 3P) HQR2H HJD6-A, 400 HJXD6-A (2P, 3P) Branch Breaker Type Number of Poles Voltage Amperes QP, BQ, BL, 1 QPH, BQH, BLH, 2 HQP, HBQ, HBL 3 QAF2, BAF2, QAF, BQAF, BAF, QAFH2, BAFH2, HQAF2, HBAF2, QAFH, BQAFH, BAFH, QFGA2, 1 BFGA2 HQFGA2, HBF- GA2, QFGAH2, BFGAH2 QAF, BAF, QAFH, BAFH 2 QE, BE, BLE, QPHF, BQHF, BLHF, QPF, BQF, BLF, QEH, BLEH, QPF2, 1 BLF2, HQPF2, HBLF2, QPHF2, BLHF2 QPF, BLF, BLE, BLEH, QPHF, BLHF, QEH, QE 2 ED4 1 ED4, ED6 2,3 FD6-A, FXD6-A 2,3 QJ2, QJH2, QJ2H 2,3 HQPP, QPPH, QPP 2 QR2, QRH2, HQR2 2,3 QT 1,2 NDGA, NDGB 2, 3 NFGA, NFGB 2, 3 ED4, ED6 1 ED4, ED6 2,3 NFGA, NFGB 2, 3 QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, 1 HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 1 QR2, QRH2, HQR2 2,3 FD6, FXD6 2, 3 FD6-A, FXD6-A 2, 3 1 QP, BQ, BL 2 3 QT 1,2 QFGA2, BFGA2, QAF2, BAF2, QAF, BAF 1 QAF, BAF 2 QPF2, BLF2, QPF, BQF, BLF, QE, BLE, BE 1 QPF, BLF, QE, BLE 2 1 QPH, BQH, BLH 2 3 QFGAH2, BFGAH2, QAFH2, BAFH2, HQFGA2, HBFGA2, HQAF2, HBAF2, 1 QAFH, BAFH QAFH, BAFH 2 QPHF, BLHF, QPHF2, BLHF2, QEH, BLEH, 1 HQPF2, HBLF2 QEH, BLEH, QPHF, BLHF 2 1 HQP, HBQ, HBL 2 3 QS, QSH, QSHH, HQS 2 QR2, QRH2, HQR2 2,3 ED4 1 ED4, ED6 2, 3 QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, 1 HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 1 QR2, QRH2, HQR2 2,3 FD6-A, FXD6-A 2, 3 JD6-A, JXD6-A JXD2-A, SJD6-A 2, 3 NDGA, NDGB 2, 3 NFGA, NFGB 2, 3 NJGA, NJJA 2, 3 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120/240 15-20 120 15-30 120/240 15-60 120 15-100 240 15-125 240 70-250 240 60-225 120/240 125-225 240 100-250 120/240 15-40 240 50-150 240 70-250 240 15-100 240 15-125 240 70-250 120 15-20 120 15-30 240 100-250 240 70-250 240 70-250 120/240 15-70 120/240 15-125 240 15-100 120/240 15-50 120 15-20 120/240 15-20 120 15-30 120/240 15-60 120/240 15-70 120/240 15-125 240 15-100 120 15-20 120/240 15-20 120 15-30 120/240 15-60 120/240 15-70 120/240 15-125 240 15-100 120/240 100-225 240 100-250 120 15-100 240 15-125 120 15-20 120 15-30 240 100-250 240 70-250 240 200-400 240 50-150 240 70-250 240 200-400 MOLDED CASE 7 CIRCUIT BREAKERS 7-228 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Series Connected Short Circuit Ratings 240V Breaker Series Ratings (continued) Series Rating kAIR 100000 (cont.) Main Breaker Branch Breaker Type Max. Amperes Type Number of Poles Voltage ED4, ED6 1 240 ED4, ED6 2,3 240 QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, 1 120 HBFGA2, QFGAH2, BFGAH2 HJGA 400 QPF2, BLF2, HQPF2, (2P, 3P) HBLF2, QPHF2, BLHF2 1 120 NFGA, NFGB 2, 3 240 FD6, FXD6 2, 3 240 FD6-A, FXD6-A 2, 3 240 QR2, QRH2, HQR2 2,3 240 NJGA, NJJA 2, 3 240 JD6, JXD6 2, 3 240 JD6-A, JXD6-A 2, 3 240 ED4 1 120 ED4, ED6 2, 3 240 FD6-A, FXD6-A 2, 3 240 JD6-A, JXD6-A JXD2-A, SJD6-A, SJD6-B 2, 3 240 QAF2, BAF2, QAFH2, SHJD6, SHJD6-A, SHJD6-B BAFH2, HQAF2, HBAF2, 400 (3P) QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, 1 BFGAH2 120 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 1 120 QR2, QRH2, HQR2 2,3 240 NDGA, NDGB 2, 3 240 NFGA, NFGB 2, 3 240 NJGA, NJJA 2, 3 240 ED4 1 120 ED4, ED6 2,3 240 QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, 1 120 HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 1 120 HLD6-A, FD6-A, FXD6-A 2,3 240 HLXD6-A JD6-A, JXD6-A, JXD2-A, SJD6-A, SJD6-B 2,3 240 LD6-A 2,3 240 LXD6-A 2,3 240 SLD6-A, SLD6-B 3 240 QR2, QRH2, HQR2 2,3 240 NDGA, NDGB 2, 3 240 NFGA, NFGB 2, 3 240 600 (2P, 3P) NJGA, NJJA NLGA, NLGB ED4, ED6 2, 3 240 2, 3 240 1 240 ED4, ED6 2,3 240 NFGA, NFGB 2, 3 240 FD6, FXD6 2, 3 240 FD6-A, FXD6-A 2, 3 240 NJGA, NJJA 2, 3 240 JD6, JXD6 2, 3 240 JD6-A, JXD6-A 2, 3 240 HLGA, HLGB NLGA, NLGB 2, 3 240 QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, 1 120 HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 1 120 QR2, QRH2, HQR2 2,3 240 LD6, LD6-A 2, 3 240 LXD6, LXD6-A 2, 3 240 ED4 1 120 ED4, ED6 2,3 240 FD6-A, FXD6-A 2,3 240 JD6-A, JXD6-A, JXD2-A, SJD6-A, SJD6-B 2,3 240 LD6-A 2,3 240 SHLD6, SHLD6-A, SHLD6-B 600 (3P) LXD6-A SLD6-A, SLD6-B QAF2, BAF2, QAFH2, 2,3 240 3 240 BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, 1 120 HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 1 120 Amperes 15-100 15-125 15-20 15-30 70-250 70-250 70-250 100-250 200-400 200-400 200-400 15-100 15-125 70-250 200-400 15-20 15-30 100-250 50-150 70-250 200-400 15-100 15-125 15-20 15-30 70-250 200-400 200-600 450-600 300-600 100-250 50-150 70-250 200-400 400-600 15-100 15-125 70-250 70-250 70-250 200-400 200-400 200-400 400-600 15-20 15-30 100-250 200-600 450-600 15-100 15-125 70-250 200-400 200-600 450-600 300-600 15-20 15-30 Revised on 02/06/18 General 240V Breaker Series Ratings (continued) Series Rating kAIR 100000 (cont.) Main Breaker Type Max. Amperes SHLD6, SHLD6-A SHLD6-B (cont.) 600 (3P) (cont.) HMG 800 (2P, 3P) HMD6, HMXD6 SHMD6, 800 SHMD6-B (3P) HNG 1200 (2P, 3P) Branch Breaker Type QR2, QRH2, HQR2 NDGA, NDGB NFGA, NFGB NJGA, NJJA NLGA, NLGB ED4, ED6 ED4, ED6 NFGA, NFGB FD6, FXD6 FD6-A, FXD6-A NJGA, NJJA JD6, JXD6 JD6-A, JXD6-A NLGA, NLGB LD6, LD6-A LXD6, LXD6-A NMG QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 QR2, QRH2, HQR2 LMD6, LMXD6 MD6, MXD6 NDGA, NDGB NFGA, NFGB NJGA, NJJA NLGA, NLGB NMG ED4 ED4, ED6 FD6-A, FXD6-A JD6-A, JXD6-A, JXD2-A, SJD6-A LD6-A LXD6-A QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 QR2, QRH2, HQR2 SLD6-A, SLD6-B MD6, MXD6 SMD6, SMD6-B NDGA, NDGB NFGA, NFGB NJGA, NJJA NLGA, NLGB NMG ED4 ED4, ED6 FD6-A, FXD6-A JD6-A, JXD6-A, JXD2-A SJD6-A, SJD6-B LD6-A LXD6-A QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 QR2, QRH2, HQR2 SLD6-A, SLD6-B MD6, MXD6, SMD6, SMD6-B ED4, ED6 ED4, ED6 NFGA, NFGB FD6, FXD6 FD6-A, FXD6-A NJGA, NJJA JD6, JXD6 JD6-A, JXD6-A NLGA, NLGB LD6, LD6-A LXD6, LXD6-A Number of Poles 2,3 2, 3 2, 3 2, 3 2, 3 1 2,3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 1 1 2,3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 1 2,3 2,3 2,3 2,3 2,3 1 1 2,3 3 2,3 3 2, 3 2, 3 2, 3 2, 3 2, 3 1 2,3 2,3 2,3 2,3 2,3 2,3 1 1 2,3 3 2,3 1 2,3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 Voltage 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 120 120 240 240 240 240 240 240 240 240 120 240 240 240 240 240 120 120 240 240 240 240 240 240 240 240 240 120 240 240 240 240 240 240 120 120 240 240 240 240 240 240 240 240 240 240 240 240 240 240 Amperes 100-250 50-150 70-250 200-400 400-600 15-100 15-125 70-250 70-250 70-250 200-400 200-400 200-400 400-600 200-600 450-600 600-800 15-20 15-30 100-250 600-800 400-800 50-150 70-250 200-400 400-600 600-800 15-100 15-125 70-250 200-400 200-600 450-600 15-20 15-30 100-250 300-600 500-800 600-800 50-150 70-250 200-400 400-600 600-800 15-100 15-125 70-250 200-400 200-400 200-600 450-600 15-20 15-30 100-250 300-600 500-800 15-100 15-125 70-250 70-250 70-250 200-400 200-400 200-400 400-600 200-600 450-600 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-229 Molded Case Circuit Breakers Revised on 05/31/19 Series Connected Short Circuit Ratings General 240V Breaker Series Ratings (continued) Series Rating kAIR 100000 (cont.) Main Breaker Type Max. Amperes HNG (cont.) 1200 (2P, 3P) HND6, HNXD6 SHND6, 1200 SHND6-B (3P) HPG 1600 (2P, 3P) Branch Breaker Type QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 QR2, QRH2, HQR2 NMG LMD6, LMXD6 NNG ND6, NXD6 ED4 ED4, ED6 FD6-A, FXD6-A JD6-A, JXD6-A, JXD2-A, SJD6-A LD6-A LXD6-A SLD6-A, SLD6-B MD6, MXD6, SMD6 ND6, NXD6, SND6, SND6-B QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 QR2, QRH2, HQR2 NDGA, NDGB NFGA, NFGB NJGA, NJJA NLGA, NLGB NMG NNG ED4 ED4, ED6 FD6-A, FXD6-A JD6-A, JXD6-A, JXD2-A, SJD6-A LD6-A LXD6-A SLD6-A, SLD6-B MD6, MXD6, SMD6, SMD6-B ND6, NXD6, SND6, SND6-B QAF2, BAF2, QAFH2, BAFH2, HQAF2, HBAF2, QFGA2, BFGA2 HQFGA2, HBFGA2, QFGAH2, BFGAH2 QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 QR2, QRH2, HQR2 NDGA, NDGB NFGA, NFGB NJGA, NJJA NLGA, NLGB NMG NNG ED4, ED6 ED4, ED6 NFGA, NFGB FD6, FXD6 FD6-A, FXD6-A NJGA, NJJA JD6, JXD6 JD6-A, JXD6-A NLGA, NLGB LD6, LD6-A LXD6, LXD6-A QR2, QRH2, HQR2 NMG LMD6, LMXD6 MD6, MXD6 NNG ND6, NXD6 NPG PD6, PXD6 Number of Poles 1 1 2,3 2, 3 2, 3 2, 3 2,3 1 2,3 2,3 2,3 2,3 2,3 3 2,3 2,3 1 1 2,3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 1 2,3 2,3 2,3 2,3 2,3 3 2,3 2,3 1 1 2,3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 1 2,3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2,3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 2, 3 Voltage 120 120 240 240 240 240 240 240 240 240 240 240 240 240 240 240 120 120 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 120 120 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 Amperes 15-20 15-30 100-250 600-800 600-800 800-1200 600-1200 15-100 15-125 70-250 200-400 200-600 450-600 300-600 500-800 500-1200 15-20 15-30 100-250 50-150 70-250 200-400 400-600 600-800 800-1200 15-100 15-125 70-250 200-400 200-600 450-600 300-600 500-800 500-1200 15-20 15-30 100-250 50-150 70-250 200-400 400-600 600-800 800-1200 15-100 15-125 70-250 70-250 70-250 200-400 200-400 200-400 400-600 200-600 450-600 100-250 600-800 600-800 400-800 800-1200 600-1200 1200-1600 1200-1600 240V Breaker Series Ratings (continued) Series Rating kAIR 100000 (cont.) 200000 Main Breaker Type Max. Amperes HPD6, HPXD6, SHPD6 SHPD6-B 1600 (3P) SHPD6, SHPD6-B HRD6, HRXD6 2000 (3P) CED6 125 (2P, 3P) Branch Breaker Type ED4 ED4, ED6 JD6-A, JXD6-A JXD2-A SJD6-A, SJD6-B LD6-A LXD6-A SLD6-A, SLD6-B MD6, MXD6, SMD6, SMD6-B ND6, NXD6, SND6, SND6-B PD6, PXD6 SPD6, SPD6-B QR2, QRH2, HQR2 NDGA, NDGB NFGA, NFGB NJGA, NJJA NLGA, NLGB NMG NNG NPG ED4 ED4, ED6 FD6-A, FXD6-A JD6-A, JXD6-A, JXD2-A SJD6-A, SJD6-B LD6-A LXD6-A SLD6-A, SLD6-B MD6, MXD6, SMD6, SMD6-B ND6, NXD6 SND6, SND6-B NPG, PD6, PXD6 SPD6, SPD6-B NDGA, NDGB NFGA, NFGB NJGA, NJJA NLGA NMG NNG NPG ED4 ED4, ED6 JD6-A, JXD6-A, JXD2-A SJD6-A, SJD6-B LD6-A LXD6-A SLD6-A, SLD6-B MD6,MXD6 SMD6, SMD6-B ND6, NXD6, SND6, SND6-B PD6, PXD6 SPD6, SPD6-B RD6, RXD6 QR2, QRH2, HQR2 NDGA, NDGB NFGA, NFGB NJGA, NJJA NLGA, NLGB NMG NNG NPG QP, BQ, BL QPH, BQH, BLH, HQP, HBQ, HBL QAF2, BAF2, QAF, BQAF, BAF, QAFH2, BAFH2, HQAF2, HBAF2, QAFH, BQAFH, BAFH, HQFGA2, HBFGA2, QFGA2, QFGAH2, BFGAH2 BAF, QAF, BAFH, QAFH QPHF, BQHF, BLHF,QPF, BQF, BLF, QEH, QE, BE, BLEH, BLE QEH, BLEH, QAHF, QE, QPHF, BLHF, QPF, BLE, BLF ED4, HED4 ED4, ED6, HED4, HED6 QT NGB,HGB,LBG Number of Poles Voltage 1 240 2,3 240 Amperes 15-100 15-125 2,3 240 200-400 3 240 200-400 2,3 240 200-600 2,3 240 450-600 3 240 300-600 2,3 240 500-800 3 240 600-800 2,3 240 500-1200 2,3 240 1200-1600 3 240 1400-1600 2,3 240 100-250 2, 3 240 50-150 2, 3 240 70-250 2, 3 240 200-400 2, 3 240 400-600 2, 3 240 600-800 2, 3 240 800-1200 2, 3 240 1200-1600 1 240 15-100 2,3 240 15-125 2,3 240 70-250 2,3 240 200-400 3 240 200-400 2,3 240 200-600 2,3 240 450-600 3 240 300-600 2,3 240 500-800 3 240 500-800 2,3 240 500-1200 3 240 500-1200 2,3 240 1200-1600 3 240 1400-1600 2, 3 240 50-150 2, 3 240 70-250 2, 3 240 200-400 2, 3 240 400-600 2, 3 240 600-800 2, 3 240 800-1200 2, 3 240 1200-1600 1 240 15-100 2,3 240 15-125 2,3 240 200-400 3 240 200-400 2,3 240 200-600 2,3 240 450-600 3 240 300-600 2,3 240 500-800 3 240 500-800 2,3 240 500-1200 3 240 500-1200 2,3 240 1200-1600 3 240 1200-1600 2,3 240 1600-2000 2,3 240 100-250 2,3 240 50-150 2,3 240 70-250 2,3 240 200-400 2,3 240 400-600 2,3 240 600-800 2,3 240 800-1200 2,3 240 1200-1600 1 120/240 15-70 2 120/240 15-125 3 240 15-100 1 120 15-20 2 120/240 15-20 1 120 15-30 2 1 2,3 1,2 1,2,3 120/240 15-60 120 15-100 240 15-125 120/240 15-40 240 15-125 MOLDED CASE 7 CIRCUIT BREAKERS 7-230 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Series Connected Short Circuit Ratings 240V Breaker Series Ratings (continued) Series Rating kAIR 200000 (cont.) Main Breaker Type Max. Amperes LDGA, LDGB 150 (2P, 3P) CFD6 250 (2P, 3P) LFGA, LFGB CJD6-A 400 (2P, 3P) LJGA HHJD6, HHJXD6 HHLD6, HHLXD6 600 (2P, 3P) CLD6-A Branch Breaker Type NGB,HGB,LBG NDGA, NDGB, HDGA, HDGB QP, BQ, BL, QPH, BQH, BLH, HQP, HBQ, HBL QAF2, BAF2, QAF, BQAF, BAF, QAFH2, BAFH2, HQAF2, HBAF2, QAFH, BQAFH, BAFH, HQFGA2, HBFGA2, QFGA2, QFGAH2, BFGAH2 BAF, QAF, BAFH, QAFH QPHF, BQHF, BLHF, QE, BE, BLE, QPF, BQF, BLF, QEH, BLEH, QAF, BAF QPHF, BLHF, QE, BLE, QPF, BLF, QEH, BLEH, QAF, BAF ED2 HED4, ED4 ED4, ED6, HED4, HED6 FD6-A, FXD6-A HFD6, HFXD6 QJ2H, QJH2, QJ2 QPPH, QPP QT NGB,HGB,LBG NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NGB,HGB,LBG NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB HFD6, HFXD6 QPH, BQH, BLH, HQP, HBQ, HBL ED4, ED6 FD6-A, FXD6-A HFD6, HFXD6 JXD2-A, JD6-A, JXD6-A, HJD6-A, HJXD6-A QT NGB,HGB,LBG NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA NGB,HGB,LBG NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB HFD6, HFXD6 NJGA, HJGA, NJJA FD6-A, FXD6-A HFD6, HFXD6 NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA FD6-A, FXD6-A HFD6, HFXD6 NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB QPH, BQH, BLH HQP, HBQ, HBL ED4, ED6 FD6-A, FXD6-A HFD6, HFXD6 JXD2-A, JD6-A, JXD6-A, HJD6-A, HJXD6-A LD6-A, HLD6-A Number of Poles Voltage Amperes 1,2,3 240 15-125 2, 3 240 50-150 1 120/240 15-70 2 120/240 15-125 3 240 15-100 1 120 15-20 2 120/240 15-20 1 120 15-30 2 1,2,3 1 2,3 2,3 2,3 2 1,2 1,2,3 2, 3 2, 3 1,2,3 2, 3 2 3 2,3 2,3 120/240 15-60 120/240 15-100 120 15-100 240 15-125 240 70-250 240 60-225 120/240 125-225 120/240 15-40 240 15-125 240 50-150 240 70-250 240 15-125 240 50-150 240 70-250 240 70-250 120/240 100-125 240 100 240 15-125 240 70-250 2,3 1,2 1,2,3 2, 3 1,2,3 2, 3 2 3 2, 3 2, 3 2, 3 2 3 2,3 2,3 2,3 2,3 240 200-400 120/240 15-30 240 15-125 240 50-150 240 70-250 240 200-400 240 15-125 240 50-150 240 70-250 240 70-250 240 200-400 240 70-250 240 50-150 240 70-250 240 200-400 240 70-250 240 50-150 240 70-250 240 200-400 240 400-600 120/240 100-125 240 100 240 15-125 240 70-250 240 200-400 240 200-600 Revised on 05/31/19 General 240V Breaker Series Ratings (continued) Series Rating kAIR 200000 (cont.) Main Breaker Branch Breaker Type Max. Amperes Type CLD6-A (cont.) LLGA, LLGB CMD6 LMG SCMD6, SCMD6-A SCMD6-B CND6-A LXD6-A, HJXD6-A QT NGB,HGB,LBG NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA 600 (2P, 3P NLGA, HLGA, NLGB, HLGB NGB,HGB,LBG NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB HFD6, HFXD6 NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB ED4 ED4, ED6, HED4, HED6 FD6-A, FXD6-A, HFD6, HFXD6 JXD2-A, JD6-A, JXD6-A, HJD6-A HJXD6-A LD6-A, HLD6-A LXD6-A, HLXD6-A MD6, MXD6, HMD6, HMXD6 NDGA, NDGB, HDGA, HDGB 800 (2P, 3P NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB NMG, HMG HFD6, HFXD6 MD6, MXD6 HMD6, HMXD6 NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB NMG, HMG MD6, MXD6, HMD6, HMXD6 NDGA, NDGB, HDGA, HDGB 800 (3P) NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB NMG, HMG ED4, ED6 ED4, ED6, HED4, HED6 FD6-A, FXD6-A, HFD6, HFXD6 JXD2-A, JD6-A, JXD6-A, HJD6-A, HJXD6-A LD6-A, HLD6-A LXD6-A, HLXD6-A 1200 MD6, MXD6, (2P, 3P) HMD6, HMXD6 ND6, NXD6, SHND6, HND6,HNXD6 NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB NMG, HMG Number of Poles Voltage Amperes 2,3 1,2 1,2,3 240 450-600 120/240 15-30 240 15-125 2 - 3 240 50-150 240 240 240 1,2,3 240 2, 3 240 70-250 200-400 400-600 15-125 50-150 240 70-250 240 70-250 240 200-400 240 400-600 1 240 15 2,3 240 15-125 2,3 240 70-250 2,3 240 200-400 2,3 240 200-600 2,3 240 450-600 2,3 240 500-800 2,3 240 50-150 2,3 240 70-250 2,3 240 200-400 2,3 240 400-600 2,3 240 600-800 2,3 240 70-250 2,3 240 400-800 2,3 240 400-800 2,3 240 50-150 2,3 240 70-250 2,3 240 200-400 2,3 240 400-600 2,3 240 600-800 2,3 240 500-800 2,3 240 50-150 2,3 240 70-250 2,3 240 200-400 2,3 240 400-600 2,3 240 600-800 1 240 15 2,3 240 15-125 2,3 240 70-250 2,3 240 200-400 2,3 240 200-600 2,3 240 450-600 2,3 240 500-800 2,3 240 500-1200 2,3 240 50-150 2,3 240 70-250 2,3 240 200-400 2,3 240 400-600 2,3 240 600-800 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-231 Molded Case Circuit Breakers Revised on 05/31/19 Series Connected Short Circuit Ratings 240V Breaker Series Ratings (continued) Series Rating kAIR 200000 (cont.) Main Breaker Type Max. Amperes LNG 1200 (2P, 3P) SCND6-A, 1200 SCND6-B (3P) SCND6-A, 1200 SCND6-B (2P, 3P) CPD6 1600 (3P) LPG 1600 (2P, 3P) Branch Breaker Type HFD6, HFXD6 MD6, MXD6 HMD6, HMXD6 ND6,NXD6,HND6,HNXD6 NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB NMG, HMG MD6, HMD6, HMXD6, MXD6, MXD6 SHMD6, SMD6, SHMD6-B, SMD6-B NMG, HMG ND6, HND6, NXD6, HNXD6 SHND6, SND6, SHND6-B, SND6-B NDGA, NDGB, HNDGA, NDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB NMG, HMG FD6-A, FXD6-A, HFD6, HFXD6 JXD2-A, JD6-A, JXD6-A, HJD6-A, HJXD6-A LD6-A, HLD6-A LXD6-A, HLXD6-A MD6, MXD6, HMD6, HMXD6 ND6, NXD6, HND6, HNXD6, SND6 NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB NMG, HMG MD6,MXD6, HMD6, HMXD6 ND6,NXD6, HND6, HNXD6 PD6, PXD6, HPD6 HPXD6 NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB HFD6, HFXD6 NJGA, HJGA, NJJA NLGA, HLGA, NLGB, HLGB NMG, HMG Number of Poles 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 Voltage 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 240 Amperes 70-250 400-800 600-1200 50-150 70-250 200-400 400-600 600-800 400-800 400-800 600-800 500-1200 500-1200 50-150 70-250 200-400 400-600 600-800 70-250 200-400 200-600 450-600 500-800 500-1200 50-150 70-250 200-400 400-600 600-800 400-800 600-1200 1000-1600 50-150 70-250 70-250 200-400 400-600 600-800 480V Breaker Series Ratings Series Rating kAIR 18,000 25,000 35,000 42,000 Main Breaker Type ED4 ED6 NGB, HGB, LBG HED6 FD6-A, FXD6-A Max. Amperes 125 (2 & 3P) 125 (2P & 3P) 250 (2P & 3P) Branch Breaker Type BQD, CQD BQD, CQD BQD, CQD BQD, CQD ED4 ED4, ED6 NGB,HGB,LBG JD6-A, JXD6-A HED4 HJD6-A, HJXD6-A 400 (2P & 3P) 125 (2P & 3P) 400 (2P & 3P) NGB,HGB,LBG BQD, CQD ED4 ED4, ED6 NGB,HGB,LBG HFD6, HFXD6 HJD6-A, HJXD6-A, HLD6-A, HLXD6-A MD6, MXD6 SMD6 SMD6-B 50,000 ND6, NXD6 SND6 SND6-B SPD6, SPD6-B 250 (2P & 3P) 400 (2P & 3P) 600 (2P & 3P) 800 (2P & 3P) 800 (3P) 1200 (2P & 3P) 1200 (3P) 1600 (3P) NGB,HGB,LBG HED4 HED4 FD6-A, FXD6-A JD6-A,JXD6-A SJD6-A, SJD6-B LD6-A LXD6-A SLD6-A, SLD6-B NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG JD6-A, JXD6-A SJD6-A, SJD6-B LD6-A LXD6-A SLD6-A, SLD6-B LMD6, LMXD6 NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG FD6-A, FXD6-A JD6-A, JXD6-A SJD6-A, SJD6-B LD6-A LXD6-A SLD6-A, SLD6-B NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG, LMD6, LMXD6 JD6-A, JXD6-A SJD6-A, SJD6-B LD6-A LXD6-A SLD6-A, SLD6-B LMD6, LMXD6 NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG JD6-A, JXD6-A SJD6-A, SJD6-B LD6-A LXD6-A SLD6-A, SLD6-B General Number of Poles Voltage Amperes 1,2,3 1,2,3 1 2 3 1,2,3 1 2,3 1 2 3 1 2 3 1,2,3 1 2,3 1 2 3 1 2 3 277/480 15-100 277/480 277 277/480 277/480 277/480 277 480 277 277/480 277/480 277 277/480 277/480 277/480 277 480 277 277/480 277/480 277 277/480 277/480 15-100 15-100 15-100 15-100 15-100 15-100 15-125 15-125 15-125 15-125 15-125 15-125 15-125 15-100 15-100 15-125 15-125 15-125 15-125 15-125 15-125 15-125 2,3 480 15-50 2,3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 380 2,3 480 3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 3 480 15-50 70-250 200-400 200-400 200-600 450-600 400-600 50-150 70-250 250-400 400-600 600-800 200-400 200-400 200-600 450-600 400-600 600-800 50-150 70-250 250-400 400-600 600-800 70-250 200-400 200-400 200-600 450-600 400-600 50-150 70-250 250-400 400-600 600-800 200-400 200-400 200-600 450-600 400-600 600-800 50-150 70-250 250-400 400-600 600-800 200-400 200-400 200-600 450-600 400-600 MOLDED CASE 7 CIRCUIT BREAKERS 7-232 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Revised on 05/31/19 Series Connected Short Circuit Ratings 480V Breaker Series Ratings (continued) Series Rating kAIR 50,000 (cont.) Main Breaker Type PD6, PXD6 RD6, RXD6 HDGA, HDGB HFD6, HFXD6 HFGA, HFGB HJD6-A, HJXD6-A HJGA Max. Amperes 1600 (3P) 18-2000 (3P) 150 (2P & 3P) 250 (2P & 3P) 400 (2P & 3P) Branch Breaker Type FD6-A, FXD6-A JD6-A, JXD6-A SJD6-A LD6-A LXD6-A SLD6-A, SLD6-B NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG NNG NPG FD6-A, FXD6-A JD6-A, JXD6-A SJD6-A, SJD6-B LD6-A LXD6-A SLD6-A, SLD6-B NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG NNG NPG NDGA, NDGB BQD, CQD ED4, HED4 ED4, ED6, HED4, HED6 NDGA, NDGB NFGA, NFGB NDGA, NDGB NFGA, NFGB HED4, ED4 FD6-A, FXD6-A JD6-A, JXD6-A NDGA, NDGB NFGA, NFGB NJGA NDGA, NDGB NFGA, NFGB NJGA NGB,HGB,LBG HHJD6, HHJXD6 65,000 HLD6-A, HLXD6-A HHLD6, HHLXD6 NGB,HGB,LBG 600 (2P & 3P) ED4, HED4 FD6-A, FXD6-A JD6-A, JXD6-A LD6-A LXD6-A NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB NGB,HGB,LBG HLGA, HLGB HMD6, HMXD6 NGB,HGB,LBG 800 (2P & 3P) NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB FD6-A, FXD6-A JD6-A, JXD6-A LD6-A LXD6-A LMD6, LMXD6 MD6, MXD6 NDGA, NDGB, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG Number of Poles Voltage 2,3 480 2,3 480 3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 Amperes 70-250 200-400 200-400 200-600 450-600 400-600 50-150 70-250 250-400 400-600 600-800 800-1200 1200-1600 70-250 200-400 200-400 200-600 450-600 400-600 50-150 70-250 250-400 400-600 600-800 800-1200 1200-1600 2,3 480 50-150 1,2,3 277/480 15-100 1 277 15-100 2,3 480 15-125 2,3 480 480 50-150 70-250 2,3 480 480 50-150 70-250 1 277 15-100 2,3 480 70-250 2,3 480 200-400 2,3 480 50-150 2,3 480 70-250 2,3 480 250-400 2,3 480 50-150 2,3 480 70-250 2,3 480 250-400 1 277 15-125 2 277/480 15-125 3 277/480 15-125 1 277 15-125* 2 277/480 15-125* 3 277/480 15-125* 1 277 15-100 2,3 480 70-250 2,3 480 200-400 2,3 480 200-600 2,3 480 450-600 2,3 480 50-150 2,3 480 70-250 2,3 480 250-400 2,3 480 400-600 1 277 15-125 2 277/480 15-125 3 277/480 15-125 1 277 15-125* 2 277/480 15-125* 3 277/480 15-125* 2,3 480 50-150 2,3 480 70-250 2,3 480 250-400 2,3 480 400-600 2,3 480 70-250 2,3 480 200-400 2,3 480 200-600 2,3 480 450-600 2,3 480 600-800 2,3 480 400-800 2,3 480 50-150 2,3 480 2,3 480 2,3 480 2,3 480 70-250 250-400 400-600 600-800 General 480V Breaker Series Ratings (continued) Series Rating kAIR 65,000 (cont.) Main Breaker Type HMG HND6, HNXD6 HNG HPD6, HPXD6 HPG HRD6, HRXD6 LDGA, LDGB Max. Amperes 800 (2P & 3P) (cont.) 1200 (2P & 3P) 1600 (3P) 1600 (2P & 3P) 18-2000 (3P) 150 (2P & 3P) Branch Breaker Type LMD6,LMXD6 MD6,MXD6 SMD6, SMD6-B NDGA, NDGB, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG FD6-A, FXD6-A JD6-A, JXD6-A LD6-A LXD6-A MD6, MXD6 SMD6, SMD6-B LMD6, LMXD6 NDGA, NDGB, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG NNG LMD6,LMXD6 MD6, MXD6 ND6,NXD6 NDGA, NDGB, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG NNG FD6-A, FXD6-A NDGA, NDGB, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG NNG NPG LMD6,LMXD6 MD6, MXD6 ND6,NXD6 NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG NNG NPG FD6-A, FXD6-A JD6-A, JXD6-A LD6-A LXD6-A NDGA, NDGB NFGA, NFGB NJGA NLGA, NLGB NMG NNG NPG NGB,HGB,LBG CFD6 BQD, CQD 100,000 LFGA, LFGB HHFD6, HHFXD6 NGB,HGB,LBG 250 (2P & 3P) NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB HFD6, HFXD6 NGB,HGB,LBG Number of Poles Voltage 2,3 480 2,3 480 3 480 Amperes 600-800 400-800 500-800 2,3 480 50-150 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 3 480 2,3 480 70-250 250-400 400-600 600-800 70-250 200-400 200-600 450-600 500-800 500-800 600-800 2,3 480 50-150 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 70-250 250-400 400-600 600-800 800-1200 600-800 400-800 800-1200 2,3 480 50-150 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 70-250 250-400 400-600 600-800 800-1200 70-250 2,3 480 50-150 2,3 480 70-250 2,3 480 250-400 2,3 480 400-600 2,3 480 600-800 2,3 480 800-1200 2,3 480 1200-1600 2,3 480 600-800 2,3 480 400-800 2,3 480 800-1200 2,3 480 50-150 2,3 480 70-250 2,3 480 250-400 2,3 480 400-600 2,3 480 600-800 2,3 480 800-1200 2,3 480 1200-1600 2,3 480 70-250 2,3 480 200-400 2,3 480 200-600 2,3 480 450-600 2,3 480 50-150 2,3 480 70-250 2,3 480 250-400 2,3 480 400-600 2,3 480 600-800 2,3 480 800-1200 2,3 480 1200-1600 1 277 15-125* 2 277/480 15-125* 3 277/480 15-125* 1 277/480 15-100 2,3 277/480 15-30 1 277 15-125* 2 277/480 15-125* 3 277/480 15-125* 2,3 480 50-150 2,3 480 70-250 2, 3 480 70-250 1 277 15-125* 2 277/480 15-125* 3 277/480 15-125* MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-233 Molded Case Circuit Breakers Series Connected Short Circuit Ratings 480V Breaker Series Ratings (continued) Series Rating kAIR Main Breaker Type HHJXD6, HHJD6, CJD6-A LJGA HHLD6, HHLXD6 LLGA, LLGB 100,000 (cont.) CMD6 LMG SCMD-A SCMD6-B SCND6-A SCND6-B LNG Max. Amperes 400 (2P, 3P) 600 (2P, 3P) 800 (3P) 800 (2P, 3P) 800 (3P) 1200 (3P) 1200 (2P, 3P) Branch Breaker Type ED4, ED6, HED4, HED6 HFD6, HFXD6, FXD6-A, FD6-A NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA NGB,HGB,LBG NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB HFD6, HFXD6 ED4, ED6, HED4, HED6 HFD6, HFXD6, FXD6-A, FD6-A NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB HFD6, HFXD6 NJGA , HJGA FD6-A, FXD6-A HFD6-A, HFXD6-A JD6-A, HJD6-A, JXD6-A, HJXD6-A LD6-A, HLD6-A LXD6-A, HLXD6-A MD6, MXD6, HMD6, HMXD6 NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA NLGA, HLGA, NLGB, HLGB NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB HFD6, HFXD6 NJGA, HJGA NLGA, NLGB, HLGA, HLGB MD6, MXD6, HMD6, HMXD6 Number of Poles Voltage 1 277 2,3 480 2,3 480 2,3 480 2,3 480 1 277 2 277/480 3 277/480 2,3 480 2,3 480 2,3 480 1 277 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 Amperes 15-100 70-250 50-150 70-250 200-400 15-125* 15-125* 15-125* 50-150 70-250 70-250 15-100 70-250 50-150 70-250 200-400 50-150 70-250 70-250 200-400 70-250 200-400 200-600 450-600 500-800 50-150 70-250 200-400 400-600 50-150 70-250 70-250 200-400 400-600 500-800 HFD6, HFXD6 2,3 480 70-250 HFD6, HFXD6 2,3 480 NDGA, NDGB, HDGA, HDGB 2,3 480 NFGA, NFGB, HFGA, HFGB 2,3 480 HFD6, HFXD6 2,3 480 NJGA, HJGA 2,3 480 NLGA, HLGA, NLGB, HLGB 2,3 480 MD6, MXD6, HMD6 HMXD6 2,3 480 ND6, NXD6, HND6 HNXD6 2,3 480 70-250 50-150 70-250 70-250 200-400 400-600 400-800 600-1200 Revised on 05/31/19 General 480V Breaker Series Ratings (continued) Series Rating kAIR Main Breaker Type CND6 100,000 (cont.) CPD6 LPG (2,3P) CJD6-A 150,000 CLD6-A CED6 200,000 CFD6 Max. Amperes 1200 (3P) 1600 (3P) 1600 (2P, 3P) 400 (2P, 3P) 600 (2P, 3P) 125 (2P, 3P) 250 (2P, 3P) Branch Breaker Type FD6-A, FXD6-A HFD6-A, HFXD6-A JD6-A, HJD6-A JXD6-A, HJXD6-A LD6-A, HLD6-A LXD6-A, HLXD6-A MD6, MXD6 HMD6, HMXD6 ND6, NXD6 HND6, HNXD6 NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA NLGA, HLGA, NLGB, HLGB FD6-A, FXD6-A HFD6-A, HFXD6-A NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB NJGA, HJGA NLGA, HLGA, NLGB, HLGB NDGA, NDGB, HDGA, HDGB NFGA, NFGB, HFGA, HFGB HFD6, HFXD6 NJGA, HJGA NLGA, NLGB, HLGA, HLGB MD6, MXD6, HMD6, HMXD6 ND6, NXD6, HND6 HNXD6 PD6,PXD6, HPD6 HPXD6 ED4 HFD6, HFXD6 JD6-A, HJD6-A, JXD6-A, HJXD6-A ED4 HFD6, HFXD6 JD6-A, HJD6-A, JXD6-A, HJXD6-A LD6-A, HLD6-A LXD6-A, HLXD6-A BQD, CQD ED4, HED4 ED4, ED6, HED4, HED6 NGB,HGB,LBG BQD, CQD ED4, ED6 ED4, HED4 HED4, HED6 FD6-A, FXD6-A, HFD6, HFXD6 Number of Poles Voltage 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 480 2 - 3 480 480 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 2,3 480 1 277 2,3 480 2,3 480 1 277 2,3 480 2,3 480 2,3 480 2,3 480 1 277 2,3 277/480 1 277 2,3 480 1 277 2 277/480 3 277/480 1 277 2,3 277/480 2,3 277 1 480 2,3 480 2,3 480 Amperes 70-250 70-250 200-400 200-600 450-600 500-800 500-1200 50-150 70-250 200-400 400-600 70-250 50-150 70-250 200-400 400-600 50-150 70-250 70-250 200-400 400-600 500-800 500-1200 1200-1600 15-100 70-250 200-400 15-100 70-250 200-400 200-600 450-600 15-100 20-30 15-100 15-125 15-125 15-125 15-125 15-100 20-30 15-50 15-100 15-125 70-250 1 277 15-125 NGB,HGB,LBG 2 277/480 15-125 3 277/480 15-125 MOLDED CASE 7 CIRCUIT BREAKERS 7-234 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers Series Connected Short Circuit Ratings 240V Fuse Series Ratings Series Rating kAIR 65,000 100,000 Main Fuse Branch Breaker Max. Type Amperes Type Number of Poles J, R 15-600 (1,2,3P) QPH, BQH, BLH 1,2,3 T 15-1200 (1,2,3P) QPH, BQH, BLH 1,2,3 L 601-6000 (1,2,3P) QPH, BQH, BLH 1,2,3 QP, BQ, BL 1,2,3 HQP, HBQ, HBL, QPH, BQH, BLH 3 QPF, BQF, BLF, QHPF, T 15-200 (1,2,3P) (300V) QE, BE, BLE, QEH, BLEH, BLHF, BQHF, QAF, BAF, 1 QAFH, BAFH QEH, BLEH, QE, QPF, QPHF, BLHF, BLE, BLF, 2 QAF, BAF, QAFH, BAFH QT 1,2 15-600 (1,2,3P) QPH, BQH, BLH, HQP, HBQ, HBL 1,2 ED4, HED4 1 ED4, ED6, HED4, HED6 2,3 QAF2, BAF2, QAFH2, 15-600 (2,3P) BAFH2, QFGA2, BFGA2, 1 QFGAH2, BFGAH2 J, R 70-600 (2,3P) QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 1 FD6-A, FXD6-A 2,3 100-600 (2,3P) QR2, QRH2, HQR2 2,3 200-600 (2,3P) JD6-A, JXD6-A, JXD2-A, SJD6-A, SJD6-B 2,3 LD6-A 2,3 300-600 (3P) SLD6-A, SLD6-B 3 450-600 (2,3P) LXD6-A 2,3 ED4, HED4 1 ED4, ED6, HED4, HED6 2,3 QAF2, BAF2, QAFH2, 15-1200 (2,3P) BAFH2, HQAF2, HBAF2, QFGA2, BFGA2, QF- 1 GAH2, BFGAH2 T QPF2, BLF2, HQPF2, HBLF2, QPHF2, BLHF2 1 70-1200 (2,3P) FXD6-A, FD6-A 2,3 100-600 (2,3P) QR2, QRH2, HQR2 2,3 450-1200 (2,3P) LXD6-A 2,3 JD6-A, JXD6-A, 200-1200 (2,3P) JXD2-A SJD6-A, SJD6-B 2,3 3 LD6-A 2,3 300-1200 (3P) SLD6-A, SLD6-B 3 ED4, HED4 1 ED4, ED6, HED4, HED6 2,3 FD6-A, FXD6-A 2,3 JD6-A, JXD6-A, JXD2-A 2,3 SJD6-A, SJD6-B 3 L 601-6000 (2,3P) LD6-A LXD6-A 2,3 2,3 SLD6-A, SLD6-B 3 SMD6, SMD6-B 3 SND6, SND6-B 3 PD6, PXD6, SPD6 3 RD6, RXD6 3 Max. Amperes 15-125 15-125 15-125 15-125 15-100 15-30 15-60 15-50 15-125 15-100 15-125 15-20 15-30 70-250 100-250 200-400 200-600 300-600 450-600 15-100 15-125 15-20 15-30 70-250 100-250 450-600 200-400 200-400 200-600 300-600 15-100 70-250 200-400 200-400 200-600 450-600 300-600 500-800 500-1200 1200-1600 1600-2000 Revised on 02/06/18 240V Fuse Series Ratings (continued) Series Rating kAIR Main Fuse Max. Type Amperes R 125-200 (2,3P) 125-600 T, J (2,3P) 125-400 (2,3P) J, R 70-600 (2,3P) 70-1200 T 600-1200 (2,3P) L 601-6000 (2,3P) J,R 200,000 J,R J,R J,R J,R T T T T T L 15-600 (1,2,3P) 50-600 (2,3P) 70-600 (2,3P) 200-600 (2,3P) 400,600 (1,2,3P) 15-1200 (1,2,3P) 50-1200 (2,3P) 70-1200 (2,3P) 200-1200 (2,3) 400-1200 (2,3P) 601-6000 (2,3P) Branch Breaker Type QJH2, QJ2H, QJ2 QJH2, QJ2H QJ2 HFD6, HFXD6 HFD6, HFXD6 NMG, HMG HFD6, HFXD6 MD6, MXD6, HMD6, HMXD6 NMG, HMG ND6, NXD6, HND6, HNXD6 NGB,HGB,LBG NDGA, HDGA NFGA, HFGA NJGA, HJGA NLGA, HLGA NGB,HGB,LBG NDGA, HDGA NFGA, HFGA NJGA, HJGA NLGA, HLGA NDGA, HDGA NFGA, HFGA NJGA, HJGA NJGA, HLGA General Number of Poles 2,3 Max. Amperes 125-200 2,3 125-225 2,3 125-225 2,3 70-250 2,3 70-250 2,3 600-800 2,3 70-250 2,3 500-800 2,3 600-800 2,3 500-1200 1,2,3 15-125 2,3 50-150 2,3 70-250 2,3 200-400 2,3 400-600 1,2,3 15-125 2,3 50-150 2,3 70-250 2,3 200-400 2,3 400-600 2,3 50-150 2,3 70-250 2,3 200-400 2,3 400-600 MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-235 Molded Case Circuit Breakers Series Connected Short Circuit Ratings 480V Fuse Series Ratings Series Rating kAIR 50,000 100,000 200,000 Main Fuse Type Max. Amperes J 60-400 (1,2,3P) 15-400 (2,3P) J 15-400 (1,2,3P) T, J 70-600 (2,3P) J, R 70-600 (2,3P) T, J, R T 200-600 (2,3P) 450-600 (2,3P) 70-1200 (2,3P) T, L 601-1200 (2,3P) L 601-6000 (2,3P) J,R 50-600 (2,3P) J,R 70-600 (2,3P) J,R 200-600 (2,3P) J,R 400-600 (2,3P) T 601-1200 (2,3P) T 601-1200 (2,3P) T 601-1200 (2,3P) T 601-1200 (2,3P) L 601-6000 (2,3P) R 15-100 (1,2,3P) T, J 15-200 (1,2,3P) Branch Breaker Type ED4 ED4 ED4 FD6-A, FXD6-A HFD6, HFXD6 JD6-A, JXD6-A HJD6-A, HJX LD6-A, HLD6 LXD6-A, HLD6 HFD6, HFXD6 JD6-A, JXD6-A HJD6-A, HJX LD6-A, HLD6 LXD6-A, HLX HFD6, HFXD6 MD6, MXD6 HMD6, HMXD6 ND6, NXD6 HND6, HNXD6 NDGA, HDGA NFGA, HFGA NJGA, HJGA NLGA, HLGA NDGA, HDGA NFGA, HFGA NJGA, HJGA NLGA, HLGA NDGA, HDGA NFGA, HFGA NJGA, HJGA NLGA, HLGA NDGA, HDGA NFGA, HFGA NJGA, HJGA NLGA, HLGA BQD, CQD BQD, CQD BQD, CQD BQD, CQD Number of Poles 1 2,3 1 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 Max. Amperes 60-100 15-100 15-50 70-250 70-250 200-400 200-600 450-600 70-250 200-400 200-600 450-600 70-250 500-800 2,3 500-1200 2,3 50-150 2,3 70-250 2,3 200-400 2,3 400-600 2,3 50-150 2,3 70-250 2,3 200-400 2,3 400-600 2,3 50-150 2,3 70-250 2,3 200-400 2,3 400-600 2,3 50-150 2,3 70-250 2,3 200-400 2,3 200-400 1 15-100 2,3 20-30 1 15-100 2,3 20-30 Revised on 03/25/17 General MOLDED CASE 7 CIRCUIT BREAKERS 7-236 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Molded Case Circuit Breakers IEC 947-2® AC Interrupting Ratings, 50/60 HZ KA Ampere Rating 15-125 70-250 Breaker Frame ED FD 250-400 JD 400-600 LD 600-800 MD 800-1200 ND Breaker Type ED6 FXD6 HFXD6 HHFXD6 JXD6(A) HJXD6(A) LXD6(A) HLXD6(A) MXD6 HMXD6 NXD6 HNXD6 220/240 Volts Icu Ics 65 17 65 33 100 50 200 100 65 33 100 50 65 33 100 50 65 33 100 50 65 33 100 50 380/415 Volts Icu Ics 35 9 35 18 65 33 100 50 40 20 65 33 40 20 65 33 40 20 65 33 40 20 65 33 Revised on 05/31/18 Reference 500 Volts Icu Ics -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- MOLDED CASE 7 CIRCUIT BREAKERS Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-237 Molded Case Circuit Breakers Typical Specifications General Specifications Molded case circuit breakers shall provide circuit overcurrent protection with inverse time and instantaneous tripping characteristics and shall be Siemens Sentron, Sensitrip or approved equal. All circuit breakers shall be listed by Underwriters' Laboratories, Inc., conform to applicable requirements of NEMA Standard Publication No. AB1 and meet appropriate classifications of Federal Specifications W C 375B/Gen. All circuit breakers shall have a quick-make, quick-break over center toggle type mechanism and the handle mechanism shall be trip free to prevent holding contacts closed against a short circuit or sustained overload. All circuit breaker handles shall assume a position between "ON" and "OFF when tripped automatically. Multi-pole circuit breakers shall be common-trip such that an overload or short circuit on any one pole will result in all poles opening simultaneously. Arc extinction is to be accomplished by magnetic arc chutes. All ratings are to be clearly visible. When reverse feed is indicated on the drawings, in accordance with UL, circuit breakers with sealed trip units shall be supplied. Thermal Magnetic Specifications Unless otherwise noted on the drawings, all Circuit breakers 2000 Ampere and below shall have thermal-magnetic trip units, with inverse time-current characteristics. Automatic operation of these circuit breakers shall be obtained by means of thermal-magnetic tripping devices located in each pole providing inverse time delay and instantaneous circuit protection. Circuit breakers shall be ambient compensating in that, as the ambient temperature increases over 40°C, the circuit breaker automatically derates itself so as to better protect its associated conductor. Thermal magnetic breakers from 250 to 2000A frames shall have thermal interchangeable trip units, with instantaneous magnetic trip settings that are adjustable and accessible from the front of all circuit breakers on frame sizes 250 Amperes and above. Where indicated, provide circuit breakers UL listed for application at 100% of their continuous ampere rating in their intended enclosure. Motor Circuit Protectors Where indicated on the drawings and in the combination motor starter/motor control center schedule, furnish instantaneous magnetic trip only circuit breakers for motor short circuit protection. The magnetic trips shall be adjustable and accessible from the front of all circuit breakers frames. The continuous current rating shall be between 1 and 800 Amperes as indicated on the drawing. Reference Solid State Sensing Specifications As indicated on the drawings, circuit breaker frames 400 Ampere through 3200-Ampere shall have microprocessor-based RMS sensing trip units, with the capability to measure through to the 21st harmonic. Automatic operation of all circuit breaker frames 400A and larger shall be obtained by means of solid state tripping elements providing inverse time delay and (instantaneous) and/or (short-time delay) circuit protection. Continuous current ratings shall be adjustable from 20% to 100% of the trip unit rating, without the need for a rating plug. Long-time delay and instantaneous trip shall be adjustable. The optional short-time trip function shall have adjustable pick-up settings, three fixed times, and I2t ramp. Circuit breaker frames 400A and larger, and where indicated on the drawings, shall be 100% equipment rated. Integral Ground Fault Option Main and feeder circuit breakers, as indicated on the drawings, shall be provided with integral ground fault protection. Ground fault pick-up shall be adjustable from 20% to 70% of the circuit breakers maximum continuous current rating. Ground fault time delay shall be adjustable with three 12t ramps. Metering Option When indicated on the drawings, solid state trip breakers shall be furnished with a plug-in or panel mounted metering device. This device shall simultaneously display all three phase currents, as well as average current, ground current, and phase unbalance. In addition it shall display breaker status, a max log, and a trip log. The trip log will retain and display date, time and type of trip (overload, short circuit or ground fault) for the most recent 5 trip events. MOLDED CASE 7 CIRCUIT BREAKERS The interrupting rating of the circuit breakers shall be as indicated in the specifications, and shown on the drawing or single line diagram. The interrupting rating of the circuit breakers shall be at least equal to the available short circuit current at the line terminals of the circuit breaker and correspond to the UL listed integrated short circuit current rating specified. Internal Accessories Provide shunt trips, bell alarms, and auxiliary switches as shown on the contract drawings. Gold plated auxiliary switches shall be supplied for PLC connection. Internal accessories for all breakers shall be UL listed for field installation and modification. Connection Accessories Unless otherwise noted, Mechanical lugs shall be provided with all Molded Case Breakers. Where indicated on the drawings, compression lugs shall be provided on 1200 Ampere frame and below circuit breakers. All compression lugs shall be supplied by the Circuit Breaker Manufacturer. Where indicated on the drawings, UL listed plug-in or rear connectors shall be supplied. 7-238 Siemens Industry, Inc. SPEEDFAXTM Product Catalog Current Limiting Specifications Where indicated on the drawings, Siemens current limiting circuit breakers are to be furnished. Current limiting circuit breakers shall limit the let-through I2t to a value less than the I2t of one-half cycle wave of the symmetrical prospective current without any fusible elements when operating within its current range. Series Connected Combination Specifications Where protective devices are applied in series combination, such that the prospective available fault current exceeds the interrupting rating (AIR) of the downstream protective devices, such combinations shall be UL recognized combinations. All electrical equipment using these UL recognized circuit breaker combinations shall be clearly marked in accordance with NEC Section 240-83(c). Molded Case Circuit Breakers Superseded Breakers Sentron Series CED62B015-CED62B125 CED62S100A CED63A001-CED63A125 CED63B015-CED63B125 CED63S100A HHED63B015-HHED63B125 CFD62A150, CFD62L150, CFD62A250 CFD62B070-CFD62B250 CFD62S250A CFD63A150, CFD63L150, CFD63A250 CFD63B070-CFD63B250 CFD63S250A CJD62B200-CJD62B400 CJD62H400, CJD62L400 CJD62S400A CJD63B200-CJD63B400 CJD63H400, CJD63L400 CJD63S400A CPD63B120-CPD63B160 ED21B015-ED21B100 ED22B015-ED22B100 ED22S100A ED23B015-ED23B100 ED23S100A ED41B015-ED41B100 ED42B015-ED42B125 ED42S100A ED43B015-ED43B125 ED43S100A ED61B015-ED61B100 ED62B015-ED62B125 ED62S100A ED63A001-ED63A125 ED63B015-ED63B125 ED63S100A HHED63B015-HHED63B125 FD62B070-FD62B250 f FD63B070-FD63B250 f FXD62A150, FXD62L150, FXD62A250 FXD62B070-FXD62B250 f FXD62S250A FXD63A150, FXD63L150, FXD63A250 FXD63B070-FXD63B250 f FXD63S250A HED41B015-HED41B100 HED42B015-HED42B125 HED43B015-HED43B125 HED61B015-HED61B100 HED63B015-HED63B125 HFD62B070-HFD62B250 HFD63B070-HFD63B250 HHED63B015-HHED63B125 HJD63B200-HJD63B400 HLD63B250-HLD63B600 HMD63B500-HMD63B800 HND63B100-HND63B120 HPD63B120-HPD63B160 HRD63B160-HRD63B200 Note a a a a a a a a a a a a a a a a a a e a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a b b b b Superseded CLE62B015-CLE62B100 CLE62S100 CLE63A001-CLE63A125 CLE63B015-CLE63B100 CLE63S100 HED63B015-HED63B125 CLF62A150, CLF62A250 CLF62B070-CLF62B240 CLF62S250 CLF63A150, CLF63A250 CLF63B070-CLF63B250 CLF63S250 CLJ62B100-CLJ62B400 CLJ62L400, CLJ62H400 CLJ62S400 CLJ63B200-CLJ63B400 CLJ63L400, CLJ63H400 CLJ63S400 CP3B120-CP3B160 E21B015-E21B100 E22B015-E22B100 E22S100A E23B015-E23B100 E23S100A E41B015-E41B100 E42B015-E42B100 E42S100 E43B015-E43B100 E43S100 E61B015-E61B100 E62B015-E62B100 E62S100A E63A001-E63A125 E63B015-E63B100 E63S100A HED63B015-HED63B125 F62B070, F62B250 F63B070-F63B250 FJ62A150, FJ62L150-FJ62A250 FJ62B070-FJ62B250 FJ62S250 FJ63A150, FJ63L150-FJ63A250 FJ63B070-FJ63B250 FJ63S250 HE41B015-HE41B100 HE42B015-HE42B100 HE43B015-HE43B100 HE61B015-HE61B100 HE63B015-HE63B100 HF62B070-HF62B250 HF63B070-HF63B250 HED63B015-HED63B125 HJ63B200-HJ63B400 HL63B450-HL63B600 HN3B500-HN3B800 HK3B100-HK3B120 HP3B120-HP3B160 HR3B160-HR3B200 Note c c c c Superseded CE2B015-CE2B100 CE2S100 CE3B015-CEB100 CE3S100 General c CJ2B125-CJ2B250 c CJ3B125-CJ3B250 d CJ2B300-CJ2B400 d CJ2S400 d CJ3B300-CJ3B400 d CJ3S400 b EE1B015-EE1B100 b EE2B015-EE2B100 b EE2S100 b EE3B015-EE3B100 b EE3S100 b EH1B015-EH1B100 b EH2B015-ED2B125 b EH2S100 b EH3B015-EH3B100 b EH3S100 b EF1B015-EF1B020 b EF2B015-EF2B100 b EF2S100 b EF3A003, EF3J050, EF3L050-EF3A100, EF3H1 b EF3B015-EF3B100 b EF3S100 b FJ2B070-FJ2B225 b FJ2S225 b FJ3A225 b FJ3B070-FJ3B225 b FJ3S225 b HE2B015-HE2B100 b HE3B015-HE3B100 b HJ3B125-HJ3B400 b HL3B450-HL3B600 MOLDED CASE 7 CIRCUIT BREAKERS aMechanically and electrically interchangeable. bElectrically interchangeable only, refer to sales office for further details. cElectrically interchangeable only if the system interrupting capacity is less than or equal to: 200 kA at 240V AC 200 kA at 480V AC 100 kA at 600V AC dElectrically interchangeable only if the system interrupting capacity is less than or equal to: 200 kA at 240V AC 150 kA at 480V AC 100 kA at 600V AC eRefer to local sales office for replacement information. fEffective 1994 -- The FD6 and FXD6 types have been replaced by FD6-A and FXD6-A type thermal / magnetic circuit breakers --mechanically and electrically interchangeable with the exception that FXD6-A and FD6-A have 22kA at 600V ACratings versus 18kA at 600V AC for types FXD6 and FD6. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-239 Molded Case Circuit Breakers Superseded Breakers Revised on 02/06/18 General Sentron Series JD62B200-JD62B400 JD63B200-JD63B400 JXD22B200-JXD22B400 JXD22S400A JXD23B200-JXD23B400 JXD23S400A JXD62B200-JXD62B400 JXD62H400, JXD62L400 JXD62S400A JXD63B200-JXD63B400 JXD63H400, JXD63L400 JXD63S400A LD62B250-LD62B500 LD62B250-LD63B600 LXD62B450-LXD62B600 LXD62J600, LXD62L600 LXD62S600A LXD63B450-LXD63B600 LXD64H600, LXD63L600 LXD63S600A MD62B500-MD62B800 MD63B500-MD63B800 MXD62A800, MXD62H800, MXD62L800 MXD62S800A MXD63A800, MXD63H800, MXD63L800 MXD63S800A ND63B100-ND63B900 NXD63S120A PD63B120-PD63B160 PXD63S160A RD63B160-RD63B200 QR22B100 QR22B225 QR22B100H QR22B225H HQR23S250HA QJ23B100 QR23B225 QR23B100H QR23B225H QRH22B100 QRH22B225 QRH23B100 QRH23B225 HQR23S250HA QJH22B060-QJH22B225 QJH23B060-QJH23B225 QJH23S225 RD63B160-RD63B200 RXD63S200A SCJD6B200LI-SCJD6B400LI SCJD6B200LIG-SCJD6B400LIG SCJD6B200LSIG-SCJD6B400LSIG SCJD6B200LSI-SCJD6B400LSI SCLD6B300LI-SCLD6B600LI SCLD6B300LIG-SCLD6B600LIG SCLD6B300LSIG-SCLD6B600LSIG SCLD6B300LSI-SCLD6B600LSI SCMD6B600LI-SCMD6B800LI SCMD6B600LIG-SCMD6B800LIG SCMD6B600LSIG-SCMD6B800LSIG SCMD6B600LSI-SCMD6B800LSI Note a a a a a a a a a a a a a a a b a a a a b b b b b b b b b b b a a a b b a a a a a a a a a a a a Superseded JLB200-JL62B400 JL63B200-JL63B400 JD22B200-JD22B400 JD22S400 JD23B200-JD23B400 JD23S400 JJ62B200-JJ62B400 JL62L400, JL62H400 JJ62S400A JJ63B200-JJ63B400 JL63A400, JL63H400, JL63L400 JJ63S400A LL63B250-LL62B600 LL63B250-LL63B600 LJ62B450-LJ62B600 LL2H600, LL2U600, LL2X600 LJ62S600 LJ63B450-LJ63B600 LL63H600, LL63L600 LJ63S600A KM2B500-KM2B800 KM3B500-KM3B800 KM2A800, KM2H800, KM2L800 KM2S800 KM3A600, KM3H800, KM3L800 KM3S800 KP3B100-KP3B900 KP3S120 HP3B120-HP3B160 HP3S160 HR3B160-HR3B200 QJ22B060-QJ22B225 QJ22B060H-QJ22B225H QJ22S225 QJ23B060-QJ23B225 QJ23B060H-QJ23B225H QJH22B060-QJH22B225 QJH23B060-QJH23B225 QJH23S225 QJ2H125-QJ2B225 QJ3H125-QJ3H225 QJ3S225 HR3B160-HR3B200 HR3S200 SCJD69200-SCJD69400 SCJD69200G-SCJD69400G SCJD69200NGT-SCJD69400NGT SCJD69200NT-SCJD69400NT SCLD69300-SCLD69600 SCLD69300G-SCLD69600G SCLD69300NGT-SCLD69600NGT SCLD69300NT-SCLD69600NT SCMD69600A-SCMD69800A SCMD69600AG-SCMD69800AG SCMD69600ANGT-SCMD69800ANGT SCMD69600ANT-SCMD69800ANT Note b b b b b b b b b b b b b b a Superseded JL2B070-JL2B400 JL3B0L0-JL3B400 JD2B250-JD2B400 JD2S400 JD3B250-JD3B400 JD3S400 JJ2B250-JJ2B400 JL2L400-JL2H400 JJ3B200-JJ3B400 JL3H400, JL3L400, JL3A225 LL2B450-LL2B600 LL3B450-LL3B600 LL3A450, LL3H600 LL3S600 aMechanically and electrically interchangeable. bElectrically interchangeable only, refer to sales office for further details. cElectrically interchangeable only if the system interrupting capacity is less than or equal to: 200 kA at 240V AC 200 kA at 480V AC 100 kA at 600V AC 7-240 Siemens Industry, Inc. SPEEDFAXTM Product Catalog d Electrically interchangeable only if the system interrupting capacity is less than or equal to: 200 kA at 240V AC 150 kA at 480V AC 100 kA at 600V AC eRefer to local sales office for replacement information. MOLDED CASE 7 CIRCUIT BREAKERS Molded Case Circuit Breakers Superseded Breakers Revised on 02/06/18 General Sentron Series SCND6B800LI-SCND6B120LI SCND6B800LIG-SCND6B120LIG SCND6B800LSIG-SCND6B120LSIG SCND6B800LSI-SCND6B120LSI SHJD6B200LI-SHJD6B400LI SHJD6B200LIG-SHJD6B400LIG SHJD6B200LSIG-SHJD6B400LSIG SHJD6B200LSI-SHJD6B400LSI SHLD6B300LI-SHLD6B600LI SHLD6B300LIG-SHLD6B600LIG SHLD6B300LSIG-SHLD6B600LSIG SHLD6B300LSI-SHLD6B600LSI SHND6B100LI-SHND6B120LI SHND6B100LIG-SHND6B120LIG SHPD6B140LI-SHPD6B160LI SHPD6B140LIG-SHPD6B160LIG SHND6B100LSIG-SHND6B120LSIG SHND6B100LSI-SHND6B120LSI SJD6B200LI-SJD6B400LI SJD6B200LIG-SJD6B400LIG SJD6B200LSIG-SJD6B400LSIG SJD6B200LSI-SJD6B400LSI SLD6B300LI-SLD6B600LI SLD6B300LIG-SLD6B600LIG SLD6B300LSIG-SLD6B600LSIG SLD6B300LSI-SLD6B600LSI SMD6B600LI-SMD6B800LI SMD6B600LIG-SMD6B800LIG SMD6B600LSIG-SMD6B800LSIG SMD6B600LSI-SMD6B800LSI SND6B800LI-SND6B120LI SND6B800LIG-SND6B120LIG SND6B800LSIG-SND6B120LSIG SND6B800LSI-SND6B120LSI SHPD6B140LI-SHPD6B160LI SHPD6B140LIG-SHPD6B160LIG SHPD6B140LSIG-SHPD6B160LSIG SHPD6B140LSI-SHPD6B160LSI -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Note a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a d d d d d d d d d c c c Superseded SCND69800A-SCND69120A SCND69800AG-SCND69120AG SCND69800ANGT-SCND69120ANGT SCND69800ANT-SCND69120ANT SHJD69200-SHJD69400 SHJD69200G-SHJD69400G SHJD69200NGT-SHJD69400NGT SHJD69200NT-SHJD69400NT SHLD69300-SHLD69600 SHLD69300G-SHLD69600G SHLD69300NGT-SHLD69600NG SHLD69300NT-SHLD69600NT SHND69100A-SHND69120A SHND69100AG-SHND69120AG SHPD69140-SHPD69160 SHPD69140G-SHPD69160G SHND69100NGT-SHND69800NGT SHND69100NT-SHND69800NT SJD69200-SJ369400 SJD69200G-SJD69400G SJD69200NGT-SJD69400NGT SJD69200NT-SJD69400NT SLD69300-SLD69600 SLD69300G-SLD69600G SLD69300NGT-SLD69600NGT SLD69300NT-SLD69600NT SMD69600A-SMD69800A SMD69600AG-SMD69800AG SMD69600ANGT-SMD69800ANGT SMD69600ANT-SMD69800ANT SND69800A-SND69120A SND69800AG-SND69120AG SND69800ANGT-SND69120ANGT SND69800ANT-SND69120ANT SPD69140-SPD69160 SPD69140G-SPD69160G SPD69140NGT-SPD69160NGT SPD69140NT-SPD69160NT BQCC1B015-BQC1B030 CC1B015-CC1B030 CC2B015-CC2B030 CC3B015-CC3B030 EF2A003, EF2H050, EF2L050, EF2A100 EF2H150, EF2L150 EH1B015-EH1B100 EH2B015-EH2B100 EH3B015-EH3B100 HE2A003, HE2H050, HE2L050-HE2A100 HE3A003, HE3H050, HE3L050-HE3A100 HE3B015-HE3B100 Note a a a a a a a a a a b b a b a a a a a a a a a a a a a a a a b b b b Superseded SHJ63B200-SHJ63B400G SHJ63B200G-SHJ63B400G SHJ63N200G-SHJ63N400G SHJ63N200-SHJ63N400 SHL63B300-SHL63B600 SHL63B300G-SHL63B600G SHL63N300G-SHL63N600G SHL63N300-SHL63N600 SHND69100-SHND69800 SHND69100G-SHND69800G SHPF3B120-SHPF3B160 SHPF3B120G-SHPF3B160G SHKF3N100G-SHKF3N800G SHKF3N100-SHKF3N800 SJL63B200-SJL63B400 SJL63B200G-SJL63B400G SJL63N200G-SJL63N400G SJL63N200-SJL63N400 SLL63B300-SLL63B600 SLL63B300G-SLL63B600G SLL63N300G-SLL63N600G SLL63N300-SLL63N600 SMD69600-SMD69800 SMD69600G-SMD69800G SMD69600NGT-SMD69800NGT SMD69600NT-SMD69800NT SND69100-SND69800 SND69100G-SND69800G SND69100NGT-SND69800NGT SND69100NT-SND69800NT SHPF3B120-SHPF3B160 SHPF3B120G-SHPF3B160G SHPF3N120-SHPF3N160G SHPF3N120G-SHPF3N160G MOLDED CASE 7 CIRCUIT BREAKERS aMechanically and electrically interchangeable. bElectrically interchangeable only, refer to sales office for further details. cThese units are for replacement purposes only. Consult sales office for availability. dThese units are no longer manufactured, and no replacement is available. Siemens Industry, Inc. SPEEDFAXTM Product Catalog 7-241 Molded Case Circuit Breakers Notes 7-242 Siemens Industry, Inc. SPEEDFAXTM Product Catalog MOLDED CASE 7 CIRCUIT BREAKERS