LiftMaster Logic 5.0 Commercial Door Operator
USER'S GUIDE
Security+ 2.0®
myQ®
Models
T, APT, H, J, HJ, GH, GT, SD, and GSD
Important Information
NOT FOR RESIDENTIAL USE
THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED DOOR SYSTEMS TECHNICIAN ONLY.
Operators are shipped in C2 operating mode.
Visit www.liftmaster.com to locate a professional installing dealer in your area.
2 YEAR WARRANTY
Serial #:
Installation Date:
[UL Listed Mark]
LiftMaster 300 Windsor Drive Oak Brook, IL 60523 LiftMaster.com
CONTACT INFORMATION
⚠️ WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
INTRODUCTION
Congratulations on purchasing a quality LiftMaster Logic 5.0 Commercial Door Operator.
The Logic 5.0 operator provides everything you know and trust in the prior version, plus the new features listed below:
myQ® Smart Facility Access
myQ® technology enables secure monitoring and control of Logic 5.0 operators and other myQ accessories from anywhere with a mobile device or computer using the myQ app and myQ® Smart Facility Management platform. See page 3 for more information.
Security+ 2.0®
Increased security - with every click a new code is sent to the commercial door operator ensuring the door opens only for the individual pressing the remote.
Enhanced radio communicates with tri-band frequency to improve range and reduce interference - assuring the door opens, stops and closes conveniently and reliably every time.
Dual Voltages
Single phase operators provide (115V and 230V)
3 phase operators provide (208/230V and 460V)
575V operator
CYCLE RATINGS
STANDARD DUTY:
Models T, APT, J, DJ, H, DHJ, & SD
Up to 25 cycles/hr. at peak periods.
Up to 80-90 cycles/day.
HEAVY DUTY:
Models GT, GH, & GSD
25 cycles/hr. constant high loading
in excess of 90 cycles/day.
myQ® SMART FACILITY ACCESS
LiftMaster offers a connected experience for all sizes of businesses and their access needs.
myQ® Technology
myQ® technology uses a 900MHz signal to communicate securely with connected devices to myQ-created accessories or to a Wi-Fi network. A LiftMaster Internet Gateway model 828LM or a LiftMaster myQ® Home Bridge model 819LMB is required for Wi-Fi internet connectivity. (See Accessories page 10).
myQ® App
Download the myQ app and follow the on-screen prompts to connect your commercial products. The myQ app enables secure monitoring and control of Logic 5.0 operators and other myQ connected accessories with a mobile device.
The myQ app is free and does not require an annual activation fee.
Connected operators receive current firmware updates.
myQ® Facility Management
myQ® Facility Management is a premium cloud-based platform to manage access for unlimited facilities, users and vehicles from anywhere. Monitor and control access to loading docks, gated entries and dock positions from a universal platform.
Facility dashboards provide the right people visibility into all the facilities access points.
Assign access to the facility based on a specific user role, device permissions, and scheduling.
Notification management allows specific users visibility and insight into process related issues or when something is out of place.
Commercial "Intelligence" reporting provides insight to schedule maintenance based on equipment usage (instead of calendar-based maintenance), identify energy savings opportunities, and monitor overall time spent to access open times.
A connected dock door operator provides complete visibility into dock operations including event/alerts, traffic, personnel, dock door status, dock door/gate lock, forklift sensing, and trailer location. Enhance overall efficiency at each dock position.
SETUP A myQ® SMART FACILITY MANAGEMENT ACCOUNT
NOTE: If you have an existing myQ® account, your Smart Facility Management account will have the same password.
Call LiftMaster Customer Care at 800.323.2276 to activate a Smart Facility Management account.
You will receive a welcome email from LiftMaster with instructions to register and login to your account.
Set up the facility and add users and groups to provide access to the facility (see the help in Smart Facility Management).
Follow on-screen prompts to get your Logic 5.0 Commercial Door Operator, myQ® enabled devices and additional devices connected.
Visit myLiftMaster.com for more information about myQ® connected solutions.
PROGRAMMING myQ® DEVICES:
Press and release the RADIO button on the logic board to enter programming mode. The RADIO LED will light.
Place the myQ enabled device into learn mode, see the instructions for the device.
When programming is complete, the RADIO LED will turn off.
NOTE: The operator will exit programming mode in 3 minutes if programming is not completed, and the RADIO LED will turn off.
TO ERASE ALL myQ® ENABLED DEVICES:
Press and release the RADIO button on the logic board (the RADIO LED will light).
Press and hold the RADIO button for 5 seconds. The RADIO LED will flash for approximately 5 seconds and the RADIO LED will turn off.
[Diagram showing the RADIO button and LED on the logic board]
All myQ enabled devices are now erased.
PROGRAMMING
⚠️ WARNING
To prevent possible SEVERE INJURY or DEATH:
Install a LiftMaster Monitored Entrapment Protection (LMEP) Device.
NEVER wear watches or rings when opening or inside of the enclosure with power on.
Avoid contact with any wiring or connection points inside of the enclosure.
ALWAYS use only one hand inside of the enclosure when pressing buttons on the printed circuit logic board.
NEVER permit children to operate or play with door control push buttons or remote controls.
Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel.
ALWAYS keep door in sight until completely closed. NEVER permit anyone to cross the path of closing door.
REMOTE CONTROLS
Built in 3-channel, Security+2.0® radio receiver allows you to add up to 90 remote control devices and up to 30 keyless entry devices.
NOTE: The following programming requires a LiftMaster Monitored Entrapment Protection (LMEP) Device.
SINGLE BUTTON REMOTE CONTROL
Steps:
Press and release the RADIO button (RADIO LED will light). [Diagram: Press RADIO button on logic board]
Press and hold the remote control button until the RADIO LED flashes rapidly, then release remote control button. The RADIO LED will then remain on solid after releasing the button. Repeat to add additional remote control(s). [Diagram: Press remote button until LED flashes rapidly]
Press and release the RADIO button to complete the programming. The programming mode is exited if no activity is performed within 30 seconds. [Diagram: Press RADIO button to finish]
3-BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS 3-BUTTON CONTROL STATION
NOTE: The feature will use 3 of the 90 memory channels in the operator.
Steps:
Press and release the RADIO button on the logic board (the Radio LED will light). [Diagram: Press RADIO button]
Press and release the desired button on the logic board (OPEN, CLOSE or STOP). The Radio LED will flash and then stay on solid. [Diagram: Press OPEN/CLOSE/STOP button]
Press and hold the desired button of the remote control until Radio LED flashes rapidly, then release. [Diagram: Press remote button until LED flashes rapidly]
Press and release the RADIO button to complete the programming. The programming mode is exited if no activity is performed within 30 seconds. [Diagram: Press RADIO button to finish]
Repeat steps 1 through 4 to program additional buttons.
TO ERASE ALL REMOTE CONTROLS
Press and hold the RADIO button on the logic board until the RADIO LED flashes rapidly (approximately 5 seconds). All remote controls will be erased. [Diagram: Press and hold RADIO button until LED flashes rapidly]
NOTICE: To comply with FCC and/or Industry Canada (IC) rules, adjustment or modifications of this transceiver are prohibited. THERE ARE NO USER SERVICEABLE PARTS. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC rules and IC RSS-210. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. This device must be installed in a way where a minimum 8" (20 cm) distance is maintained between users/bystanders and device.
TIMER-TO-CLOSE
Feature: Timer automatically closes the door after preset time. All entrapment protection devices must be unobstructed.
Benefit: The door will automatically close after the preset amount of time. Great for apartment buildings, fire stations and other applications where the end user wants the door to close automatically after a specified amount of time.
Requirements: Must have at least one LiftMaster Monitored Entrapment Protection (LMEP) Device installed (refer to installation manual). Wiring type must be set to TS, T or FSTS.
TO PROGRAM MANUALLY (METHOD 1):
Close the door.
Turn the selector dial to PROG.
Press and release the TIMER button on the logic board.
Press and release the STOP button to clear the timer.
Press and release the OPEN button for every second the operator should wait before attempting to close the door. Press and release the CLOSE button for every 15 seconds the operator should wait before closing the door.
Press and release the TIMER button to complete programming. The OPEN/CLOSE button LEDs will flash to confirm the timer setting. The OPEN LED will flash once for every second programmed and the CLOSE LED will flash once for every 15 seconds programmed.
Turn the selector dial to desired timer wiring type (TS, T or FSTS).
Example: To close the door after 70 seconds. Turn selector dial to PROG, press and release the TIMER button, press and release the STOP button to clear the timer, press and release the CLOSE button four times for 60 seconds and press and release the OPEN button 10 times for 10 seconds. Press the TIMER button to finish programming the timer. Turn the selector dial to desired timer wiring type (TS, T, or FSTS).
[Diagram: Selector Dial showing positions T, TS, E2, FSTS, DIAG, C2, OPTN, B2, PROG. Text indicates "Operation will vary depending on wiring type"]
PROGRAM TIMER-TO-CLOSE BY EXAMPLE (METHOD 2):
TO PROGRAM:
Close the door.
Turn the selector dial to PROG.
Press and hold TIMER button for 5 seconds until OPEN and CLOSE LEDs flash then release.
Press and release the OPEN button and wait for the door to reach full open or mid stop position.
Wait for desired amount of time to pass. (An internal stop watch starts counting when the door stops moving.)
Press and release the TIMER button, CLOSE button or STOP button to stop the timer. (TIMER SET LED will turn on.)
Turn the selector dial to the desired wiring type (T, TS, FSTS).
NOTE: To read back the Timer-To-Close setting, turn the selector dial to DIAG and press the TIMER button. The OPEN LED will flash once for every second programmed and the CLOSE LED will flash once for every 15 seconds programmed.
In T Mode, timer can be deactivated from the open position by pressing the STOP button. The timer will be reactivated on the next operation command. The STOP button WILL NOT deactivate the timer in the TS mode. To deactivate the timer for more than one cycle in T mode or in TS mode, attach a defeat switch to 11 and 12 (COMMON and TIMER DEFEAT).
[Diagram: Selector Dial showing positions T, TS, E2, FSTS, DIAG, C2, OPTN, B2, PROG. Text indicates "Operation will vary depending on wiring type"]
MANUAL RELEASE
⚠️ WARNING
To prevent possible SERIOUS INJURY or DEATH from a falling door or arm:
DO NOT stand under the door arm when pulling the emergency release.
If possible, use emergency release handle to disengage trolley ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
NEVER use emergency release handle unless doorway is clear of persons and obstructions.
EMERGENCY DISCONNECT SYSTEM MODEL GT AND T
TO DISCONNECT DOOR FROM OPERATOR
The door should be in the fully closed position if possible.
Lift free end of door arm to trolley. Pull emergency release handle to allow arm to engage roll pin. Release handle. Emergency disconnect will close. [Diagram: Lift arm, pull handle, release handle]
EMERGENCY DISCONNECT SYSTEM MODEL APT
TO DISCONNECT DOOR FROM OPERATOR
The door should be in the fully closed position if possible.
Pull down on the emergency release handle and raise or lower the door manually. [Diagram: Pull handle down, move door]
TO RECONNECT DOOR ARM TO TROLLEY
The trolley will reconnect on the next UP or DOWN operation, either manually or by using the door control or remote.
EMERGENCY DISCONNECT SYSTEM MODEL H, GH, J, AND HJ
This operator has provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions below for your model operator.
⚠️ CAUTION
To prevent possible SERIOUS INJURY from a moving chain:
DISCONNECT electric power to the operator BEFORE manually operating your door.
If possible, use emergency disconnect ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.
NEVER use emergency disconnect unless doorway is clear of persons and obstructions.
MODEL H AND GH
These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. To operate the hoist:
Pull the disconnect chain (sash chain) to engage the hoist mechanism. The disconnect chain may be locked in position by slipping the end through the keyhole of the chain keeper mounted on the wall. [Diagram: Pull chain, lock in keyhole]
Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain.
The disconnect chain must be released from the chain keeper before the door will operate again electrically.
MODEL J
This operator has a floor level disconnect chain to disconnect the door from the door operator.
To disengage, pull the disconnect chain (sash chain) and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall. [Diagram: Pull chain, secure in bracket]
The door may now be pushed up or pulled down manually.
Release the disconnect chain to operate the door again electrically.
MODEL HJ
This operator includes both a floor level disconnect chain (sash chain) to disconnect the door from the door operator and a disconnect chain with manual hoist to electrically disable the operator controls.
Pull the disconnect chain to engage the hoist mechanism. The disconnect chain may be locked in position by slipping the end through the keyhole chain keeper mounted on the wall. [Diagram: Pull chain for hoist, lock in keyhole]
To disengage, pull the disconnect chain and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall. [Diagram: Pull chain for floor disconnect, secure in bracket]
Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain.
Release the disconnect chain to operate the door again electrically.
Verify photoelectric sensors are aligned. If photoelectric sensors are aligned and operator still does not operate properly, contact your installing dealer.
RADIO FUNCTIONALITY
NO RESPONSE
Remote control is not programmed
See PROGRAMMING REMOTE CONTROLS section.
REMOTE CANNOT BE PROGRAMMED
Low battery
Replace battery.
Low battery
Replace battery.
POOR RANGE
Low battery in remote
Replace battery.
Possible radio interference
Contact your installing dealer.
MAINTENANCE SCHEDULE
⚠️ WARNING
To avoid SERIOUS personal INJURY or DEATH:
Disconnect electric power BEFORE performing ANY adjustments or maintenance.
ALL maintenance MUST be performed by a trained door systems technician.
Every 3 months or 5,000 cycles repeat all tests in the Testing section.
Call a trained door systems technician. To locate a dealer in your area visit us online at www.liftmaster.com.
The operator should be serviced at the following intervals:
Every 3 months or 5,000 cycles
Every 6 months or 10,000 cycles
Every 12 months or 20,000 cycles
ACCESSORIES
ENTRAPMENT PROTECTION DEVICES
MONITORED
CPS-U: Dual-Sided Infrared Photoelectric Sensors. NEMA 1 enclosure, indoor use, max range 30 ft (9.1 m).
CPS-UN4: Monitored Thru-Beam Photoelectric Sensors. Heavy-duty NEMA 4 enclosure, indoor/outdoor use, max range 45 ft (13.7 m).
CPS-RPEN4: Monitored Retro-Reflective Photoelectric Sensors. Polarized reflector, NEMA 4X enclosure, indoor/outdoor use, max range 50 ft (15 m).
CPS-OPEN4: Monitored Dual-Sided Photoelectric Sensors. Flexible housings, NEMA 4X enclosure, indoor/outdoor use, max range 45 ft (13.7 m).
Optical Edge System (OES):
OES-SD16: 16 ft (4.9 m) Sectional 2-Wire Door Edge Kit with infrared optical sensors, rubber door edge, mounting hardware.
OES-SD24: 24 ft (7.3 m) Sectional 2-Wire Door Edge Kit with infrared optical sensors, rubber door edge, mounting hardware.
OES-RD16: 16 ft (4.9 m) Rolling 2-Wire Door Edge Kit with infrared optical sensors, rubber door edge, mounting hardware.
Rubber door edge is durable, flexible, easy to install, premium rubber can be cut to length. NEMA 6 rating protects against moisture. Infrared optical sensors eliminate electrical contacts. Max range 33 ft (10 m). Available in 50 ft (15 m) bulk rolls.
MONITORED ACCESSORIES
CPS3CARD: Safety Interface Card. Enables use of a second set of monitored photo eyes or edge.
CPS-MEI: Edge Interface 2-Wire Monitored. For use with approved 2-wire edges.
CPS-EI: Edge Interface 4-Wire Monitored. For use with approved 4-wire edges.
NON-MONITORED ACCESSORIES
65-5202: Vehicle Detection System. Pneumatic Sensing Edge Kit with exterior air switch, 2-wire coil cord and 14 ft (4.3 m) air hose.
65-8202: Vehicle Detection System. Pneumatic Sensing Edge Kit with exterior air switch, 2-wire take-up reel (20 ft [6 m] extended) and 14 ft (4.3 m) air hose.
LC-36A: Light Curtain. Non-monitored entrapment protection device forming a 3-foot cross-pattern of invisible light beams for maximum property protection.
100MAPS: Plug-In Power Supply. Provides power to the LC-36A Light Curtain.
myQ ACCESSORIES
828LM: LiftMaster® Internet Gateway. Enables owners to open/close doors and control lights remotely via mobile device or computer.
819LMB: myQ® Home Bridge. Utilizes smartphone control for myQ enabled products without built-in Wi-Fi.
829LM: Garage and Gate Monitor. Monitor open/closed status for up to 4 myQ compatible commercial door openers or gate operators.
825LM: Remote Light Control. Automatically control lights using commercial door opener, Security+ 2.0 remote control, or LiftMaster® Internet Gateway.
REMOTE CONTROLS WITH SECURITY+ 2.0® AND CONNECTIVITY
811LM: Encrypted DIP Switch Single-Button Remote Control. Ideal for commercial applications requiring many remotes for a common space.
813LM: Encrypted DIP Switch Three-Button Remote Control. Includes Red, Yellow, and Green markings for Open, Close, Stop.
877LM: Wireless Keypad. Programmable with temporary access codes for visitors or delivery personnel.
CONTROL STATIONS
02-101: 1-Button Control Station. Steel enclosure.
02-102: 2-Button Control Station. Steel enclosure.
02-103L: 3-Button Control Station. Steel enclosure with Maintenance Alert System.
02-110: Key Control Station. Indoor flush mount, NEMA 1 with Stop button.
02-401M: 1-Button Control Station. Indoor/outdoor surface mount, single button to activate opening one commercial door.
RADIO
STAR1000: Commercial Access Control Receiver. Connects up to 1000 LiftMaster® remote controls. Supports suspending/unsuspending remote controls.
850LM: Universal Receiver. Features Security+ 2.0 technology. Designed for gated communities and commercial buildings.
MOUNTING BRACKETS
10-12360: Heavy gauge steel bracket for vertical or horizontal mount on coil of a rolling door. Compatible with many OEM manufacturers. For use with J, H, DJ, and DH operators. May be welded.
08-9098: Cast iron bracket to mount J, H, DH, DJ, and GH side mount operators on end bracket of a rolling door or grill. For vertical or horizontal mount. Cannot be welded.
08-9098EZ: Same as 08-9098, but with adapter plate for easy mounting.
1A4324: Heavy gauge steel bracket for vertical or horizontal mount on coil of a rolling door. For use with J, H, DJ, and DH operators. May be welded.
1A4324EZ: Same as 1A4324, but with adapter plate for easy mounting.
CHAIN TENSIONERS
For Jackshaft Type Operators
71-6023: For 1" (2.5 cm) shafts. Recommended to properly tension drive chain between operator shaft and door shaft.
71-6125: Same as 71-6023, but for 1-1/4" (3.2 cm) shafts.
OPTION CARDS
TLS1CARD: Timer Light Status Card. Provides special functionality to activate and flash auxiliary devices like lights, bells, and horns/strobes at various door positions.
AUXCARD: Auxiliary Contact Card. Has Normally-Open and Normally-Closed contacts that actuate when the door is idle, opening, or closing.
ADDITIONAL CONTROL ACCESSORIES
86LM (15' [4.6 m]) / 86LMT (25' [7.6 m]): Antenna Extension Kit. Can be used with EXT-ANT for maximum radio receiver range.
RGL24LY: Red/Green Traffic Light. Indicates when a commercial door reaches the open position, providing assurance of safe entering/exiting and reducing potential for costly accidents. (TLS1CARD is recommended).
RGL-CTL: Red/Green Traffic Light-Compact. Similar to RGL24LY but with high-intensity LEDs and fully sealed enclosure for single lane operations.
50-HERK2: Motion Detector 24V. Microwave motion detector with two independently programmable channels.
50450: Switch Sectional Door Interlock. NEMA 4 switch disables operator control circuit when door is locked, preventing electrical operation.
T-APT-H-J-GH-GT Logic 5.0 User EN GPL Ghostscript 9.52
Related Documents
LiftMaster Logic 5.0 Commercial Door Operator User's Guide User's guide for the LiftMaster Logic 5.0 Commercial Door Operator. Details installation, programming, security features (Security+ 2.0), myQ connectivity, troubleshooting, and maintenance for models T, APT, H, J, HJ, GH, GT, SD, and GSD.
LiftMaster Logic 5.0 Commercial Door Operator User's Guide Comprehensive user guide for the LiftMaster Logic 5.0 Commercial Door Operator, detailing installation, programming, testing, troubleshooting, and maintenance. Features MyQ Technology and Security+ 2.0 for enhanced security and control.
LiftMaster Logic 5.0 DJ Jackshaft Commercial Door Operator Comprehensive product guide detailing the LiftMaster Logic 5.0 DJ Jackshaft Commercial Door Operator, highlighting its industrial-duty applications, smart features, safety mechanisms, reliability, entrapment protection options, and detailed technical specifications.
LiftMaster Logic 5.0 Commercial Door Operator User's Guide Comprehensive user's guide for the LiftMaster Logic 5.0 Commercial Door Operator, covering installation, programming, operation, manual release, testing, troubleshooting, maintenance, and accessories. Features MyQ Technology and Security+ 2.0.
LiftMaster Logic 5.0 Commercial Door Operator User's Guide Comprehensive user's guide for the LiftMaster Logic 5.0 Commercial Door Operator, covering installation, programming, manual release, testing, troubleshooting, and accessories. Features MyQ® Technology and Security+ 2.0®.
LiftMaster Logic 5.0 Commercial Door Operator Installation Manual This installation manual provides comprehensive instructions for the LiftMaster Logic 5.0 Commercial Door Operator, models GSD and SD. It covers safety information, introduction to components, assembly, installation, wiring, entrapment protection, adjustment, testing, manual release, programming, maintenance, troubleshooting, wiring diagrams, and accessories. The manual is intended for trained door systems technicians and emphasizes safety precautions.