Anker Innovations Limited T8200 Video Doorbell 2K (Wired) 2AOKB-T8200 2AOKBT8200 t8200
REPORT No.SZ19030188W08 TEST REPORT APPLICANT : Anker Innovations Limited PRODUCT NAME : Video Doorbell 2K (Wired) MODEL NAME : T8200 BRAND NAME : eufy Security FCC ID : 2AOKB-T8200 STANDARD(S) : 47 CFR Part 15 Subpart C RECEIPT DATE : 2019-03-14 TEST DATE : 2019-03-20 to 2019-04-25 ISSUE DATE : 2019-05-05 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Peng Huarui ( Supervisor ) NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page1 of 26 REPORT No.SZ19030188W08 DIRECTORY 1. Technical Information 4 1.1. Applicant and Manufacturer Information 4 1.2. Equipment Under Test (EUT) Description 4 1.3. Test Standards and Results 5 1.4. Environmental Conditions 5 2. 47 CFR Part 15C Requirements 6 2.1. Antenna requirement 6 2.2. The Max Transmission Time 7 2.3. 20dB Bandwidth 9 2.4. Conducted Emission 11 2.5. Radiated Emission15 Annex A Test Uncertainty 23 Annex B Testing Laboratory Information 24 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page2 of 26 Version 1.0 REPORT No.SZ19030188W08 Change History Date 2019-05-05 Reason for change First edition MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page3 of 26 1. Technical Information REPORT No.SZ19030188W08 Note: Provide by applicant. 1.1. Applicant and Manufacturer Information Applicant: Applicant Address: Manufacturer: ManufacturerAddress: Anker Innovations Limited Room 1318-19,Hollywood Plaza,610 Nathan Road, Mongkok, Kowloon, Hong Kong Anker Innovations Limited Room 1318-19,Hollywood Plaza,610 Nathan Road, Mongkok, Kowloon, Hong Kong 1.2. Equipment Under Test (EUT) Description Product Name: Video Doorbell 2K (Wired) Serial No: (N/A, marked #1 by test site) Hardware Version: V03 Software Version: V12 Operating Frequency: 433.92MHz Channel Number: 1 Antenna Type: LDS Antenna Antenna Gain: 0 dBi Note 1: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page4 of 26 1.3. Test Standards and Results REPORT No.SZ19030188W08 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT FCC ID Certification: No Identity Document Title 1 47 CFR Part 15(10-1-15 Edition) Radio Frequency Devices Test detailed items/section required by FCC rules and results are as below: No. Section Description Test Date Test Engineer Result 1 15.203 Antenna Requirement N/A N/A PASS 2 15.231(a)(1) The Max Transmission Time Apr 25, 2019 Zhang Guofeng PASS 3 15.231(c) 20dB Bandwidth Apr 25, 2019 Zhang Guofeng PASS 4 15.207 Conducted Emission Mar 20, 2019 Wu Zhongwen PASS 5 15.231(b) 15.209(a) Radiated Emission Apr 20, 2019 Wu Zhongwen PASS Note 1: The tests were performed according to the method of measurements prescribed in ANSIC63.10-2013. 1.4. Environmental Conditions During the measurement, the environmental conditions were within the listed ranges: Temperature (°C): Relative Humidity (%): Atmospheric Pressure (kPa): 15 - 35 30 -60 86-106 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page5 of 26 REPORT No.SZ19030188W08 2. 47 CFR Part 15C Requirements 2.1. Antenna requirement 2.1.1. Applicable Standard According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. 2.1.2. Result: Compliant The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal photos. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page6 of 26 2.2. The Max Transmission Time REPORT No.SZ19030188W08 2.2.1. Requirement A manually operated transmitter shall employ a switch that will automatically deactivate the transmitter within not more than 5 seconds of being released. 2.2.2. Test Description A. Test Setup: 2.2.3. Test procedure Set the SPA Center Frequency=Fundamental frequency, Span=0Hz, change the weep time until get the burst in the screen. Set EUT as normal operation and press Transmitter button. Set the SPA View. Delta Mark time. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page7 of 26 REPORT No.SZ19030188W08 2.2.4. Test Result The frequency(433.92MHz) is selected to perform testing to verify the max transmission time of the EUT. A. Test Verdict: Frequency (MHz) 433.92 B. Test Plots: The max transmission time 160 ms Limit 5000ms Verdict PASS (The max transmission time _433.92MHz) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page8 of 26 2.3. 20dB Bandwidth REPORT No.SZ19030188W08 2.3.1. Requirement The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the points 20 dB down from the modulated carrier. As the center frequency for the device operating is 433.92MHz, thus, the 20dB bandwidth limit is 1085 kHz. 2.3.2. Test Description A. Test Set: 2.3.3. Test procedure Set spectrum analyzer's Center Frequency =Fundamental frequency, RBW,VBW and span to applicable value with Peak in Max Hold, A PEAK output reading and 20db Bandwidth function in spectrum analyzer were taken. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page9 of 26 REPORT No.SZ19030188W08 2.3.4. Test Result The frequency(433.92MHz) is selected to perform testing to verify the 20dB bandwidth of the EUT. A. Test Verdict: Frequency (MHz) 433.92 B. Test Plots: 20 dB Bandwidth (kHz) 16.66 Limits(MHz) 1.085 Verdict PASS (Bandwidth_433.92MHz) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page10 of 26 2.4. Conducted Emission REPORT No.SZ19030188W08 2.4.1. Requirement According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency range Conducted Limit (dBµV) (MHz) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 NOTE: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. 2.4.2. Test Description A. Test Setup: The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page11 of 26 B. Equipments List: Please reference ANNEX B(4). REPORT No.SZ19030188W08 2.4.3. Test Result The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test setup: Test Mode: ADAPTER+EUT + 433.92MHz TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN B. Test Plots: MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page12 of 26 REPORT No.SZ19030188W08 NO. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.2850 26.83 22.11 2 0.7797 26.83 22.14 3 2.5760 17.34 12.20 4 5.7093 13.48 8.61 5 12.0548 12.69 7.89 6 18.6925 26.48 14.43 (L Phase) Limit (dBµV) Quai-peak 60.67 56.00 56.00 60.00 60.00 60.00 Average 50.67 46.00 46.00 50.00 50.00 50.00 Power-line Line Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page13 of 26 REPORT No.SZ19030188W08 NO. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.2310 31.60 23.28 2 0.3568 30.20 21.97 3 0.8345 29.53 20.69 4 1.1126 29.48 20.78 5 3.5440 16.40 10.07 6 24.4543 25.02 15.21 (N Phase) Limit (dBµV) Quai-peak 62.41 58.80 56.00 56.00 56.00 60.00 Average 52.41 48.80 46.00 46.00 46.00 50.00 Power-line Neutral Verdict PASS PASS PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page14 of 26 2.5. Radiated Emission REPORT No.SZ19030188W08 2.5.1. Requirement According to FCC section 15.247(d), radiated emission outside the frequency band attenuation below the general limits specified in FCC section 15.209(a) is not required. In addition, radiated emissions which fall in the restricted bands, as defined in FCC section 15.205(a), must also comply with the radiated emission limits specified in FCC section 15.209(a). According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) 0.009 - 0.490 0.490 - 1.705 1.705 - 30.0 30 - 88 88 - 216 216 - 960 Above 960 Field Strength (µV/m) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 500 Measurement Distance (m) 300 30 30 3 3 3 3 FCC Part 15.231(b) Fundamental frequency(MHz) 40.66-40.70 70-130 130-174 174-260 260-47 Above 470 Field strength of fundamental (microvolts/meter) 2250 1250 1250 to 3750 3750 3750 to 12500 12500 Field strength of spurious emission(microvolts/meter) 225 125 125 to 375 375 375 to 1250 1250 Note: 1. For Above 1000MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. 2. For above 1000MHz, limit field strength of harmonics: 54dBuV/m@3m (AV) and 74dBuV/m@3m (PK) In addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), also should comply with the radiated emission limits specified in Section 15.209(a)(above table) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page15 of 26 2.5.2. Test Description A. Test Setup: 1) For radiated emissions from 9kHz to 30MHz REPORT No.SZ19030188W08 2) For radiated emissions from 30MHz to1GHz MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page16 of 26 3) For radiated emissions above 1GHz REPORT No.SZ19030188W08 The RF absorbing material used on the reference ground plane and on the turntable have a maximum height (thickness) of 30 cm (12 in) and have a minimum-rated attenuation of 20 dB at all frequencies from 1 GHz to 18 GHz. Test site have a minimum area of the ground plane covered with RF absorbing material as specified in Figure 6 of ANSI C63.4: 2014. The test site semi-anechoic chamber has met the requirement of NSA tolerance 4dB according to the standards: ANSI C63.10:2013. For radiated emissions below or equal to 1GHz,The EUT was set-up on insulator 80cm above the Ground Plane,for radiated emissions above 1GHz, The EUT was set-up on insulator 150cm above the Ground Plane. The set-up and test methods were according to ANSI C63.10:2013. The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. For the Test Antenna: (a) In the frequency range of 9kHz to 30MHz, magnetic field is measured with Loop Test Antenna. The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna rotates about its vertical axis for maximum response at each azimuth about the EUT. (b) In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test Antenna (above 1GHz) are used. Place the test antenna at 3m away from area of the EUT, while keeping the test antenna aimed at the source of emissions at each frequency of significant MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page17 of 26 REPORT No.SZ19030188W08 emissions, with polarization oriented for maximum response. The test antenna may have to be higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed at the emission source for receiving the maximum signal. The final test antenna elevation shall be that which maximizes the emissions. The test antenna elevation for maximum emissions shall be restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane. The emission levels at both horizontal and vertical polarizations should be tested. B. Equipments List: Please reference ANNEX B(4). 2.5.3. Test Result According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak limit, it is unnecessary to perform an quasi-peak measurement. The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: The duty cycle is simply the on-time divided by the period: The duration of one cycle: 26.65ms Effective period of the cycle: 8.35 ms (615.6s×8+201.4s×17=8348.6s=8.35ms) Duty cycle: 0.31 Therefore, the average factor is found by 20log (Duty cycle) =-10.17 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page18 of 26 REPORT No.SZ19030188W08 (Duty cycle) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page19 of 26 REPORT No.SZ19030188W08 A. Test Results for Field strength of fundamental Fre. (MHz) ANT Receiver Reading UR (PK) (dBuV) AT (dB) AFactor (dB@ 3m) Final Emission _PK (dBuV/m) Limit-PK (dBµV/m) AV factor (dB) Final Emission Limit-AV _AV (dBµV/m) (dBuV/m) Verdict 433.93 H 433.93 V 64.96 64.17 6.42 16.08 6.42 16.08 87.44 86.67 100.83 -10.17 77.27 100.83 -10.17 76.50 80.83 80.83 PASS PASS (433.92MHz, Antenna Horizontal) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page20 of 26 REPORT No.SZ19030188W08 (433.92MHz, Antenna Vertical) MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page21 of 26 B. Test Results for Radiated emission Test Plots for 433.92MHz REPORT No.SZ19030188W08 Fre. (MHz) 38.498 434.268 867.672 1301.561 2169.600 3037.400 Pk (dBV/m) 26.94 55.05 39.09 51.40 56.67 54.02 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 40.00 N/A N/A N/A N/A 46.00 N/A N/A 28.92 80.83 N/A 60.83 N/A 41.23 74.00 N/A 54.00 N/A 46.50 80.83 N/A 60.83 N/A 43.85 80.83 N/A 60.83 (Antenna Horizontal, 30MHz to 5GHz) Antenna Verdict Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal PASS N/A PASS PASS PASS PASS Fre. (MHz) 101.627 434.268 1301.700 2169.700 3037.500 3744.644 Pk (dBV/m) 24.75 51.51 52.17 53.85 54.33 49.83 QP AV Limit-PK Limit-QP Limit-AV (dBV/m) (dBV/m) (dBV/m) (dBV/m) (dBV/m) N/A N/A N/A 43.50 N/A N/A N/A N/A 46.00 N/A N/A 42.00 74.00 N/A 54.00 N/A 43.68 80.83 N/A 60.83 N/A 44.16 80.83 N/A 60.83 N/A N/A 74.00 N/A 54.00 (Antenna Vertical, 30MHz to 5GHz) Antenna Vertical Vertical Vertical Vertical Vertical Vertical Verdict PASS N/A PASS PASS PASS PASS MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page22 of 26 Annex A Test Uncertainty REPORT No.SZ19030188W08 Where relevant, the following measurement uncertainty levels have been estimated for test performed on the EUT as specified in CISPR 16-1-2: Test items Uncertainty 20dB Bandwidth ±5% Transmission time ±5% Radiated Emission ±2.95dB This uncertainty represent an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page23 of 26 REPORT No.SZ19030188W08 Annex B Testing Laboratory Information 1. Identification of the Responsible Testing Laboratory Laboratory Name: Laboratory Address: Telephone: Facsimile: Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 2. Identification of the Responsible Testing Location Name: Address: Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China 3. Facilities and Accreditations All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174. MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page24 of 26 REPORT No.SZ19030188W08 4. Test Equipments Utilized 4.1 Conducted Test Equipments Equipment Name Serial No. EXA Signal Analzyer MY53470836 RF cable (30MHz-26GHz) CB01 Coaxial cable CB02 SMA connector CN01 USB Wideband Power Sensor MY54210011 Computer T430i Type N9010A RF01 RF02 RF03 U2021XA Think Pad Manufacturer Agilent Morlab Morlab HUBER-SUHNER Agilent Lenovo Cal. Date 2019.04.09 N/A N/A N/A 2019.04.16 N/A Cal. Due 2020.04.08 N/A N/A N/A 2020.04.15 N/A 4.2 Conducted Emission Test Equipments Equipment Name Serial No. Type Receiver MY56400093 N9038A LISN 812744 NSLK 8127 Pulse Limiter (20dB) 9391 VTSD 9561-D Coaxial cable(BNC) (30MHz-26GHz) CB01 EMC01 Adapter HKC0055 N/A 010-3E Manufacturer KEYSIGHT Schwarzbeck Schwarzbeck Morlab ViVo Cal. Date Cal. Due 2018.05.08 2019.05.07 2018.05.08 2019.05.07 2018.05.08 2019.05.07 N/A N/A N/A N/A 4.3 List of Software Used Description Test system Power Panel MORLAB EMCR V1.2 Manufacturer Tonscend Agilent MORLAB Software Version V2.6 V3.8 V 1.0 MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page25 of 26 REPORT No.SZ19030188W08 4.4 Radiated Test Equipments Equipment Name Serial No. Receiver MY54130016 Test Antenna Bi-Log 9163-520 Test Antenna Loop 1520-022 Test Antenna Horn 01774 Test Antenna BBHA9170 Horn #774 Coaxial cable (N male) CB04 (9KHz-30MHz) Coaxial cable (N male) CB02 (30MHz-26GHz) Coaxial cable(N male) CB03 (30MHz-26GHz) 1-18GHz pre-Amplifier MA02 18-26.5GHz pre-Amplifier MA03 Anechoic Chamber N/A Type N9038A VULB 9163 FMZB1520 BBHA 9120D BBHA9170 EMC04 EMC02 EMC03 TS-PR18 TS-PR18 9m*6m*6m Manufacturer Agilent Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck Morlab Morlab Morlab Rohde& Schwarz Rohde& Schwarz CRT Cal. Date 2018.08.04 2018.05.18 2019.02.15 2018.08.06 2018.08.02 N/A N/A N/A 2018.05.08 2018.05.08 2017.11.19 Cal.Due 2019.08.03 2019.05.17 2020.02.14 2019.08.05 2019.08.01 N/A N/A N/A 2019.05.07 2019.05.07 2020.11.18 END OF REPORT MORLAB SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page26 of 26Acrobat Distiller 9.3.2 (Windows)