Decaura Installation Manual
Wall Top Assemblies
Thank you for purchasing Decaura products. Please check over the surface and accessories carefully to avoid any damage and missing parts.
For Round Set
This set of tap consists of two separate kits, one for hot water (red washer in bottom of spindle) and another for cold water (blue washer), plus an Allen key for screws inside handles. The two units are the same except that the steering of the spindle cartridge is reversed.
Components:
No. | Description | Quantity |
---|---|---|
1 | Protection cap | x2 |
2 | Fibre washer | x2 |
3 | Spindle cartridge | x2 |
4 | O-ring (on [3]) | x2 |
5 | Locking nut | x2 |
6 | Dress flange | x2 |
7 | Handle | x2 |
8 | Screw | x2 |
9 | Button cover | x2 |
10 | Allen Key | x1 |
Diagram Description: A visual representation of the components for the round tap set, showing parts labeled 1 through 10: a chrome protection cap, a fibre washer, a spindle cartridge, an O-ring, a locking nut, a dress flange, a round handle, a screw, a button cover, and an Allen key.
Installation Steps:
- Disassemble your new tap in three steps:
- Take off the button cover [9], unscrew [8] with the Allen key and remove the handle [7].
- Take off the protection cap [1] and unscrew the dress flange [6] by hand.
- Unscrew the locking nut [5] from the Spindle Cartridge [3].
- Double check this rubber seal washer (in Red & Blue) at the base of the spindle cartridge [3] MUST be in a proper condition. This is very important to seal the tap.
- Screw in the spindle cartridge [3] by hand until it reaches the tap seat. Then GENTLY TIGHTEN with a spanner, make sure the spindle cartridge is tight with the tap seat; any gap will cause leakage.
Important: Do not screw too hard, as it will damage the rubber seal ring or Spindle.
- Place the fibre washer [2] over the spindle and screw the lock nut [5] FIRMLY with a spanner.
- Screw the dress flange [6] to the locking nut [5]. This only has to be tightened by hand.
- Rotate the spindle cartridge [3] to the end by hand (counterclockwise for hot water in the left side, and clockwise for cold water in the right). Put the handle [7] onto the spindle with the handle downward (The horizontal position for "ON", while downward for "OFF"). Fasten the handle tightly by screw [8] with the Allen key. Put the button cover [9] into the hole.
For Square Set
This set of tap consists of two separate kits, one for hot water (red washer in bottom of spindle) and another for cold water (blue washer), plus an Allen key for screws inside handles. The two units are the same except that the steering of the spindle cartridge is reversed.
Components:
No. | Description | Quantity |
---|---|---|
1 | Protection cap | x2 |
2 | Fibre washer | x2 |
3 | Spindle cartridge | x2 |
4 | O-ring (on [3]) | x2 |
5 | Locking nut | x2 |
6 | Dress flange | x2 |
7 | O-ring (inside [6]) | x4 |
8 | Screw | x2 |
9 | Button cover | x2 |
10 | Handle | x2 |
11 | Allen Key | x1 |
Diagram Description: A visual representation of the components for the square tap set, showing parts labeled 1 through 11: a chrome protection cap, a fibre washer, a spindle cartridge, an O-ring, a locking nut, a dress flange, an additional O-ring, a screw, a button cover, a square handle, and an Allen key.
Installation Steps:
- Disassemble your new tap in three steps:
- Take off the button cover [9], unscrew [8] with the Allen key and remove the handle [10].
- Take off the protection cap [1] and unscrew the dress flange [6] by hand.
- Unscrew the locking nut [5] from the Spindle Cartridge [3].
- Double check this rubber seal washer (in Red & Blue) at the base of the spindle cartridge [3] MUST be in a proper condition. This is very important to seal the tap.
- Screw in the spindle cartridge [3] by hand until it reaches the tap seat. Then GENTLY TIGHTEN with a spanner, make sure the spindle cartridge is tight with the tap seat; any gap will cause leakage.
Important: Do not screw too hard, as it will damage the rubber seal ring or Spindle.
- Place the fibre washer [2] over the spindle and screw the lock nut [5] FIRMLY with a spanner.
- Put the dress flange [6] to the locking nut [5] until against to the wall by hand.
- Rotate the spindle cartridge [3] to the end by hand (counterclockwise for hot water in the left side, and clockwise for cold water in the right). Put the handle [10] onto the spindle with the handle downward (The horizontal position for "ON", while downward for "OFF"). Fasten the handle tightly by screw [8] with the Allen key. Put the button cover [9] into the hole.
Remarks:
- Products are manufactured as per Australian Standard, and have WaterMark certificate.
- The length of the cartridge is 92mm, fit for majority users. In case the water inlet seat is too deep, you may need a lengthened spindle cartridge.
Warranty Terms
All products are guaranteed as below:
- 5 years guarantee against main body and handles.
- 3 years guarantee against cartridge and valve defaults.
- 2 years guarantee on washers and O-rings.
- 3 years guarantee on finishing.
Other Conditions
- Working pressure: 0.05-1 Mpa.
- Working temperature: 0-55°C.
- Products are manufactured as per standard AS/NZS 3718:2005.
- This wall top assemblies can be used for Wall basin taps, shower and bathtub taps.