Clevast Smart Dehumidifier

Instruction Manual

Model No.: CL-D22S

IMPORTANT SAFEGUARDS

IMPORTANT SAFETY PRECAUTIONS

Read Safety Precautions Before Operation and Installation

To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage.

⚠ WARNING: This symbol indicates the possibility of personnel injury or loss of life.

ⓘ CAUTION: This symbol indicates the possibility of property damage or serious consequences.

WARNING:

CAUTION:

NOTE ABOUT FLUORINATED GASSES (NOT APPLICABLE TO THE UNIT USING R290 REFRIGERANT):

  1. Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specific information on the type, the amount and the CO2 equivalent in tonnes of the fluorinated greenhouse gas (on some models), please refer to the relevant label on the unit itself.
  2. Installation, service, maintenance and repair of this unit must be performed by a certified technician.
  3. Product uninstallation and recycling must be performed by a certified technician.

SOCIABLE REMARK:

When using this dehumidifier in European countries, the following information must be followed:

DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities:

SAVE THESE INSTRUCTIONS

HOUSEHOLD USE ONLY

GETTING TO KNOW YOUR SMART DEHUMIDIFIER

1. IDENTIFICATION OF PARTS

Control panel

Handle(both sides)

Panel

Water level window

Water bucket

Air outlet grille

Air filter

Continuous drain hose outlet compatibility: It will fit most female coupling hose reels.

Power cord buckle (placed in the water bucket, used only when storing the unit)

Caster

Power cord and plug

2. DESIGN NOTICE

3. PRECAUTION BEFORE FIRST USE

4. POSITIONING THE UNIT

Casters (At four points on the bottom of unit)

A dehumidifier operating in a basement will have little or no effect on drying an adjacent enclosed storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

5. WHEN USING THE UNIT

6. ACCESSORIES

Package Inclusion: 1x Power cord buckle (to be placed at the back of the unit)

1x Drain cap Drain hose is not included

OPERATING INSTRUCTIONS

1. CONTROL PANEL FEATURES

Auto defrost

Full

On

Off

8.8.

COMFORT FILTER CONT. TURBO TIMER

POWER

FILTER button

The check filter feature is a reminder to clean the Air Filter for more efficient operation. The filter light (Clean filter light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the filter button and the light will go off.

TURBO Pad

Control the fan speed. Press to select either High or Normal fan speed. Set the fan control to High for maximum moisture removal. When the humidity has been reduced and quiet operation is preferred, set the fan control to Normal.

CONTINUE button

Press to activate the continuous dehumidifying operation. Note: On this operation, the unit can not be set humidity level.

Timer button

Press to initiate the Auto start and Auto stop feature, in conjunction with the and buttons.

Left/Right buttons

Humidity Set Control buttons

The humidity level can be set within a range of 35% RH (Relative Humidity) to 85% RH (Relative Humidity) in 5% increments. For drier air, press the button and set it to a lower percent value (%). For damper air, press the button and set a higher percent value (%).

TIMER Set Control buttons

Use the Left/Right buttons to set the Auto start and Auto stop time from 0.0 to 24.

POWER button

Press to turn the dehumidifier on and off.

COMFORT button

Press to activate the comfort dehumidifying operation. In Comfort dehumidifying mode, the unit will automatically control room humidity to a comfortable range of 45%~55% according to the room temperature. The humidity setting function will be invalid.

Note: On this operation, the unit can not be set humidity level.

Display

Shows the set % humidity level from 35% to 85% or auto start/stop time (0~24) while setting, then shows the actual (±5% accuracy) room % humidity level in a range of 30% RH (Relative Humidity) to 90% RH (Relative Humidity).

Error Codes and Protection Code:

Note: When one of the above malfunctions occurs, turn off the unit, and check for any obstructions. Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord. Contact the manufacturer or its service agents or a similar qualified person for service.

2. CLEVAST DEHUMIDIFIER FEATURES

Clevast App Control

The Clevast dehumidifier can be controlled via a mobile app, providing convenient access to the device's settings and allowing you to monitor and adjust the humidity level from anywhere.

Setting the Timer

When the unit is on, first press the Timer button, the Timer Off indicator light illuminates. It indicates the Auto Stop program is initiated. Press it again the Timer On indicator light illuminates. It indicates the Auto Start is initiated.

When the unit is off, first press the Timer button, the Timer On indicator light illuminates. It indicates the Auto Start program is initiated. Press it again the Timer Off indicator light illuminates. It indicates the Auto Stop is initiated.

Press or hold the LEFT OR RIGHT button to change the Auto time by 0.5hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until the start.

The selected time will register after 5 seconds and the system will automatically revert back to display the previous humidity setting.

When the Auto Start & Auto Stop times are set, within the same program sequence, Timer On Off indicator lights illuminate identifying both On and Off times are now programmed.

Turning the unit On or Off at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop function.

When the LED display window displays the code of P2, the Auto Start/Stop function will also be cancelled.

Auto Shut Off

The dehumidifier shuts off when the bucket is full, or when the bucket is removed or not replaced in the proper position.

Wait 3 minutes before resuming the operation after the unit has stopped. This is to protect the unit. Operation will automatically start after 3 minutes.

Bucket Full Light

Glows when the bucket is ready to be emptied.

Auto Defrost

When frost builds up on the evaporator coils, the compressor will cycle off and the fan will continue to run until the frost disappears.

Check filter feature

The system starts to count the time once the fan motor operates. The check filter feature can be only activated when the accumulated operation achieves 250 hours or more. The Reset light (clean filter indicator) flashes every second. After cleaning the air filter, press the Filter button and the Reset light goes off.

Auto-Restart

If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes.

3. REMOVING THE COLLECTED WATER (There are two ways to remove collected water.)

1. Use the bucket

a. Pull out the bucket a little.

b. Hold both sides of the bucket with even strength, and pull it out from the unit.

NOTE:

2. Continuous draining

Remove the plastic cover by counter-clockwise rotation.

Female threaded end

Drain hose

  • When you remove the plastic cove and there's some water in the back drain outlet of the unit, you must dry it. Make sure the hose is securely connected so there are no leaks and the end of the hose should be placed down the floor to let the water flow. This unit uses gravity drain.
  • Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing. Make sure the water hose is lower than the drain hose outlet of the unit.
  • Select the desired humidity setting and fan speed on the unit for continuous draining to start.

Note: When the continuous draining feature is not being used, remove the drain hose from the outlet, and dry the water in the continuous drain hose outlet.

4. SPECIFICATIONS

Model No.:CL-D22S
Rated voltage:115V 1Ph
Rated frequency:FREQUENCY 60HZ
Rated power:250W
Complete-built unit size:16.54 x 11.69 x 19.69 inches
Complete-built unit Net weight:32.41lbs
Applicable Ambient (RH Range Manual) :35-85%
Applicable Ambient (Ambient temp) :41-96°F
Refrigerant type:R32/3.88ozs
Air flow (Hi/Mi/Lo):135.29/-/117.65 CFM(ft3/min)
Water tank volume:3L
Noise level(Hi):51dB(A)
Plug type:18#x3/SP007

CLEVAST APP SET UP

1. DOWNLOAD THE CLEVAST APP

To download the Clevast App, please scan the QR code or search for "Clevast" in Apple App store® (iOS) or Google Play Store (Android).

Clevast App

NOTE:

  • For Android™ users, choose "Allow" to use Clevast. It won't be used to record personal, private information.
  • The Clevast App is continually being improved and may change over time. If there are any differences, follow the in-app instructions.
  • Follow the instructions to finish setting up your Dehumidifier.

2. CREATE/LOGIN YOUR OWN CLEVAST ACCOUNT

Open the Clevast App, if you already have an account, tap Log In. If you want to create a new account, tap Sign Up.

NOTE: You must create your own Clevast account to use third-party services and products. These will not work with a guest account. With a Clevast account, you can also allow your family and friends to control your dehumidifier unit.

3. SETTING UP CLEVAST APP

User must finish all the steps in 8 minutes after powering on the Dehumidifier, otherwise you need to power it on again.

  1. Turn on Bluetooth® and Wi-Fi® on your phone.
  2. Make sure your mobile device has already been connected to the Wireless network which you want to use. Also, you need to forget other irrelevant Wireless networks in case it influences your configuration process.
  3. Disconnect the power supply of dehumidifier.
  4. Connect the power supply of dehumidifier, press and hold the "FILTER" button for more than 3 seconds.

Step 1

Step 2

5. When the unit displays "AP", it means that the dehumidifier wireless has already entered into "AP" Mode.

6. Press " + Add Device "

My home

Add your first device

7. Enter the Add Device interface, select the Dehumidifier to enter the network configuration interface.

Add Device

Searching for devices...

Product list

No device found yet, please try to add manually

Step 1 of 2

Dehumidifier

E02-DH03-WTUS

Step 1: Go to phone's WiFi settings.

Step 2: Join "net_hum_001" network, Password is in device information on the device.

Step 3: Then return to Clevast App.

WiFi settings

Next Step

Exit Setup

8. Go to the phone's "WLAN" settings, use the password "12345678" to connect to the network "net_a1_XXXX".

If "net_a1_XXXX" network is not found on the WLAN. Check whether the device is in AP mode. If not, try again.

WLAN

WLAN

CHOOSE A NETWORK...

Mobie_Wifi

Mac mini 2

Wi-Fi

WiFi

Other...

Apps Using WLAN & Cellular

9. Please select family WLAN and enter the password. Please ensure that the current connection is the 2.4G wireless network!

Step 2 of 2

net_hum_001

Configure appliance to router Enter your home WiFi and WiFi password

***********

***********

My WiFi does not require a password

Next

Connection successful

Done

NOTE:

  • When finishing network configuration, APP will display success cue words on the screen.
  • Due to different internet environment, it is possible that the device status still display "offline". If this situation occurs, it is necessary to pull and refresh the device list on the APP and make sure the device status become "online". Alternatively, user can turn off the power and turn on it again, the device status will become "online" after few minutes.

4. APP FUNCTIONS

Please ensure both your mobile device and dehumidifier are connected to the Internet before using app to control the dehumidifier via the internet. Please follow the next steps:

Dehumidifier

Indoor Humidity

50%

Speed

High

Target Humidity

40% +

High

Comfortable

Plan:On

Thus, users can control dehumidifier on/off status, operation mode, target humidity, fan speed and so on.

NOTE: Not all the functions of the APP are available on the dehumidifier. For example: ION, Pump, Pure function, please check the user manual to find more information.

CYCLE PLAN

Weekly, users can make an appointment to turn on or off the dehumidifier at a specific time. Users can also choose circulation to keep the dehumidifier under schedule control every week.

Switch

Mode

Dehumidify

Comfortable

Continuous

Cycle Plan

Switch

Mode

Time

Select date

Save

Dehumidify

Comfortable

Continuous

53

54

55%

56

Mode

Time

Select date

Save

CARE & MAINTENANCE

Care and cleaning of the dehumidifier.

Turn off the dehumidifier and remove the plug from the wall outlet before cleaning.

1. CLEAN THE GRILLE AND CASE

  • Use water and a mild detergent. Do not use bleach or abrasives.
  • Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust.
  • The air intake and outlet grilles get soiled easily, so use a vacuum attachment or brush to clean.

2. CLEAN THE BUCKET

  • Every few weeks, clean the bucket to prevent growth of mold, mildew and bacteria. Partially fill the bucket with clean water and add a little mild detergent. Swish it around in the bucket, empty and rinse.

Note: Do not use a dishwasher to clean the bucket. After cleaning, the bucket must be in place and securely seated for the dehumidifier to operate.

3. CLEAN THE AIR FILTER

  • Remove the filter every two weeks based on normal operating conditions.
  • To remove the filter, pull filter outwards.
  • Wash the filter with clean water then dry.
  • Re-install the filter, replace Bucket.

DO NOT operate the dehumidifier without filter because dirt and link will clog it and reduce the performance.

CAUTION

4. WHEN NOT USING THE UNIT FOR LONG TIME PERIODS

  • After turning off the unit, wait one day before emptying the bucket. Clean the main unit, water bucket and air filter.
  • Wrap the cord with the power cord buckle.
  • Cover the unit with a plastic bag.
  • Store the unit upright in a dry, well-ventilated place.

TROUBLESHOOTING

Before calling for service, review the chart below first yourself.

No.ProblemsSolution
1Unit does not start1. Make sure the dehumidifier's plug is pushed completely into the outlet.
2. Check the house fuse/circuit breaker box.
3. Dehumidifier has reached its preset level or bucket is full.
4. Water bucket is not in the proper position.
2Dehumidifier does not dry the air as it should1. Did not allow enough time to remove the moisture.
2. Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier.
3. The humidity control may not be set low enough.
4. Check that all doors, windows and other openings are securely closed.
5. Room temperature is too low, below 5°C (41°F).
6. There is a kerosene heater or something giving off water vapor in the room.
3The unit makes a loud noise when operating1. The air filter is clogged.
2. The unit is tilted instead of upright as it should be.
3. The floor surface is not level.
4Water on floor1. Hose to connector or hose connection may be loose.
2. Intend to use the bucket to collect water, but the back drain plug is removed.
5Frost appears on the coilThis is normal. The dehumidifier has Auto defrost feature.
6ES, AS, P2 appear in the displayThese are error codes and protection codes. See the CONTROL PANEL FEATURES section.

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Increase the separation between the equipment and receiver.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC RADIATION EXPOSURE STATEMENT

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance.

To maintain compliance with FCC RF exposure compliance requirements, please follow operation instructions as documented in this manual. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.

The availability of some specific channels and/or operational frequency bands are country dependent and are firmware programmed at the factory to match the intended destination. The firmware setting is not accessible by the end user.

WARRANTY INFORMATION

We grant a 1-year warranty on the product commencing on the date of purchase. Within the guarantee period, we will eliminate any defects in the appliance resulting from faults in materials or workmanship. Please contact us at: support@clevast.com to launch a warranty claim.

This guarantee does not cover: damage due to improper use, normal wear or use as well as defects that have a negligible effect on the value or operation of the appliance. The guarantee becomes void if repairs are undertaken by unauthorized persons and if original product parts are not used.

CUSTOMER SERVICE

  1. If you have any product questions or concerns, please don't hesitate to contact us directly at support@clevast.com or visit our website at: www.clevast.com.
  2. We have a hassle-free warranty and customer service team for satisfactory solutions to any issue you might have.

CLEVAST

@CLEVAST

WWW.CLEVAST.com

Scan to Follow Us

Models: CL-D22S Smart Wi-Fi Energy Star Dehumidifier, CL-D22S, Smart Wi-Fi Energy Star Dehumidifier, Wi-Fi Energy Star Dehumidifier, Energy Star Dehumidifier, Star Dehumidifier, Dehumidifier

PDF preview unavailable. Download the PDF instead.

C1wLXIlBt0L Adobe PDF library 16.07 Adobe Illustrator 27.0 (Windows)

Related Documents

PreviewCLEVAST Smart Humidifier CL-HD01 Instruction Manual
Comprehensive instruction manual for the CLEVAST Smart Humidifier, model CL-HD01. Covers safety precautions, product features, operation, maintenance, troubleshooting, and app connectivity.
PreviewCLEVAST CL-GS01 Handheld Garment Steamer Instruction Manual
Comprehensive instruction manual for the CLEVAST CL-GS01 Handheld Garment Steamer, covering important safeguards, operation, maintenance, troubleshooting, and warranty information.