Linkplay Technology Inc. AMP003 WiiM Amp Ultra 2BABF-AMP003 2BABFAMP003 amp003
REPORT No.SZ25020263W05 TEST REPORT APPLICANT : Linkplay Technology Inc. PRODUCT NAME : WiiM Amp Ultra MODEL NAME : AMP003 BRAND NAME : WiiM FCC ID : 2BABF-AMP003 STANDARD(S) : 47 CFR Part 15 Subpart E RECEIPT DATE : 2025-03-19 TEST DATE : 2025-04-15 to 2025-05-09 ISSUE DATE : 2025-05-19 Edited by: Zeng Xiaoying (Rapporteur) Approved by: Shen Junsheng (Supervisor) NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 1 of 44 REPORT No.SZ25020263W05 DIRECTORY 1. Summary of Test Results 3 1.1. Testing Applied Standards and Methods4 1.2. Test Equipment List 5 1.3. Measurement Uncertainty 7 1.4. Testing Laboratory7 2. General Description 8 2.1. Information of Applicant and Manufacturer 8 2.2. Information of EUT8 2.3. Channel Center Frequency of EUT 9 2.4. Test Configuration of EUT 10 2.5. Test Conditions 11 2.6. Test Setup Layout Diagram 12 3. Description of Test Items and Results 14 3.1. Conducted Emission 14 3.2. Restricted Frequency Bands 15 3.3. Radiated Emission 17 Annex A Test Data and Result 19 Version 1.0 Change History Date 2025-05-19 Reason for change First edition MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 2 of 44 Summary of Test Results REPORT No.SZ25020263W05 No. Section Description Test Date Test Engineer Result Method Determination /Remark 1 15.203 Antenna Requirement N/A N/A N/ANote1 N/A 2 ANSI C63.10 Duty Cycle of the Test Signal N/A N/A N/ANote1 N/A Conducted 3 15.407(a) Output Power N/A and E.I.R.P. N/A N/ANote1 N/A Occupied 4 15.407(a) Bandwidth and Emission N/A N/A N/ANote1 N/A Bandwidth 5 15.407(a) Power Spectral Density N/A N/A N/ANote1 N/A 6 15.407(b) Emission Mask N/A N/A N/ANote1 N/A 7 15.407(d) Contention Based Protocol N/A N/A N/ANote1 N/A 8 15.407(g) Frequency Stability N/A N/A N/ANote1 N/A 9 15.207 Conducted Emission May 09, 2025 Fan Shengquan PASS No deviation Restricted 10 15.407(b) Frequency Apr. 11, 2025 Gao Jianrou PASS No deviation Bands 11 15.407(b) Radiated Emission Apr. 23, 2025 Gao Jianrou PASS No deviation Note 1: The test results of all conducted test items please refer to the module IC test report (Report No.: SZ24040154W05), which issued on Jul. 26, 2024. Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method determination" column of add, deviate or exclude from the specific method shall be explained in the "Remark" of the above table. Note 3: When the test result is a critical value, we will use the measurement uncertainty give the judgment result based on the 95% confidence intervals. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 3 of 44 REPORT No.SZ25020263W05 Testing Applied Standards and Methods According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards: No. Standards or Methods 1 47 CFR Part 15 Subpart E 2 ANSI C63.10 3 KDB 789033 D02 4 KDB 987594 D01 5 KDB 987594 D02 6 KDB 987594 D03 7 KDB 662911 D01 Description FCC Technical Requirements Procedures for Compliance Testing of Unlicensed Wireless Devices Guidelines for compliance testing of U-NII devices General guideline for U-NII 5,6,7,8 bands under Part 15 Subpart E Guidelines for compliance testing of U-NII 6GHz devices Questions and Answers for U-NII 5,6,7,8 bands under Part 15 Subpart E Emissions Testing of Transmitters with Multiple Outputs in the Same Band MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 4 of 44 Test Equipment List REPORT No.SZ25020263W05 1.2.1 Conducted Emission Test Equipment Equipment Receiver Serial No. MY56400093 LISN 8127449 Pulse Limiter (10dB) RF Coaxial Cable (DC-100MHz) VTSD 9561 F-B #206 BNC Type N9038A NSLK 8127 VTSD 9561-F MRE04 Manufacturer KEYSIGHT Schwarzbeck Cal. Date Due Date 2025.01.06 2026.01.05 2025.01.09 2026.01.08 Schwarzbeck 2024.05.30 2025.05.29 Qualwave 2024.07.02 2025.07.01 1.2.2 List of Software Used Description JS32-RE TS+ -[JS32-CE] Manufacturer Tonscend Tonscend Software Version 5.0.0 2.5.0.0 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 5 of 44 REPORT No.SZ25020263W05 1.2.3 Radiated Test Equipment Equipment Signal Analyzer Test Antenna - Bi- Log Test Antenna - Loop Test Antenna Horn Test Antenna Horn Preamplifier (10MHz-6GHz) Preamplifier (2GHz-18GHz) Preamplifier (18GHz-40GHz) RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-18GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-40GHz) RF Coaxial Cable (DC-18GHz) Anechoic Chamber Anechoic Chamber Serial No. MY56060145 Type N9020A 9163-519 VULB 9163 1519-022 FMZB1519 01774 BBHA 9120D BBHA9170 #773 46732 61171/61172 DS77209 BBHA9170 S10M100L38 02 S020180L32 03 DCLNA011840C-S MRE001 PE330 MRE002 MRE003 22290045 22290046 22120181 N/A N/A CLU18 CLU18 QA360-40KK-0.5 QA360-40KKF-2 QA500-18NN-5 9m*6m*6m 9m*6m*6m Manufacturer Agilent Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP. Decentest Pasternack Pasternack Pasternack Qualwave Qualwave Qualwave CRT CRT Cal. Date 2024.05.30 2024.06.22 2024.06.03 2024.06.22 2024.06.22 2024.05.30 2024.05.30 2024.05.30 2024.05.30 2024.05.30 2024.05.30 2024.07.03 2024.07.03 2024.07.03 2025.04.19 2022.11.30 Due Date 2025.05.29 2025.06.21 2025.06.02 2025.06.21 2025.06.21 2025.05.29 2025.05.29 2025.05.29 2025.05.29 2025.05.29 2025.05.29 2025.07.02 2025.07.02 2025.07.02 2028.04.18 2025.11.29 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 6 of 44 Measurement Uncertainty REPORT No.SZ25020263W05 Test Items Restricted Frequency Bands Radiated Emission Conducted Emission Testing Laboratory Uncertainty ±5% ±2.95dB ±2.44dB Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95% Laboratory Name Laboratory Address Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192 226174 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 7 of 44 General Description REPORT No.SZ25020263W05 Information of Applicant and Manufacturer Applicant Applicant Address Manufacturer Manufacturer Address Information of EUT Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 Product Name WiiM Amp Ultra Sample No. 4#, 25# Hardware Version A98D V02+Main Board V02 Software Version Linkplay.5.2.708867 Modulation Technology OFDMA Modulation Mode 802.11ax (HEW20), 802.11ax (HEW40), 802.11ax (HEW80) U-NII 5 (5925-6425MHz), U-NII Band U-NII 6 (6425-6525MHz), U-NII 7 (6525-6875MHz), U-NII 8 (6875-7125MHz). U-NII 5 (5955-6415MHz), Operating Frequency Range U-NII 6 (6435-6515MHz), U-NII 7 (6535-6855MHz), U-NII 8 (6875-7115MHz). Equipment Class Low Power Device 6ID 6PP 6XD 6CD Standard Power Device 6SD 6FX 6FC Antenna Type PIFA Antenna Antenna Gain (dBi) ANT1: 3.51dBi; ANT2: 3.51dBi Note 1: The test results of all conducted test items please refer to the module FCC test report (Report No.: SZ24040154W05), which issued on Jul. 26, 2024. We only recorded the radiated test result in this report. Note 2: The EUT has two antennas that cannot transmit simultaneously. Both of the two antennas were evaluated separately, only the worst test result (ANT2) were recorded in the test report. Note 3: The dedicated software was used to control the EUT continuous transmission. Note 4: For more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 8 of 44 Channel Center Frequency of EUT REPORT No.SZ25020263W05 Channel center frequency of different bandwidths Channel Center Frequency = 5950MHz + 5 x nch; 1 nch 233 Bandwidth 20MHz 40MHz 80MHz 160MHz Value of nch 1 + 4(n-1); 1 n 59 3 + 8(n-1); 1 n 29 7 + 16(n-1); 1 n 14 15 + 32(n-1); 1 n 7 Center Frequency of Low Middle and High Channel in each U-NII band Bandwidth LCH/MCH/HCH 20MHz 40MHz 80MHz LCH MCH HCH LCH MCH HCH LCH MCH HCH U-NII 5 1/1/5955 12/45/6175 24/93/6415 1/3/5965 7/51/6205 12/91/6405 1/7/5985 4/55/6225 6/87/6385 n/nch/Frequency@MHz U-NII 6 U-NII 7 25/97/6435 27/105/6475 29/113/6515 13/99/6445 -/-/14/107/6485 -/-/7/103/6465 -/-/- 30/117/6535 38/149/6695 46/181/6855 16/123/6565 19/147/6685 23/179/6845 9/135/6625 10/151/6705 11/167/6785 U-NII 8 47/185/6875 53/209/6995 59/233/7115 24/187/6885 26/203/6965 29/227/7085 13/199/6945 -/-/14/215/7025 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 9 of 44 Test Configuration of EUT REPORT No.SZ25020263W05 Modulation Type and Data Rate of EUT Mode 802.11ax Bandwidth (MHz) 20/40/80 (HEW20/40/80) Modulation Technology OFDMA Modulation Type BPSK QPSK 16QAM 64QAM 256QAM 1024QAM Data Rate MSC0~MCS11 Evaluation of The Worst Case Investigation has been done on all the possible configurations for searching the worst cases. The following table is a list of the test modes shown in this test report. Test Items Mode Conducted Emission Normal Use Restricted Frequency Bands ax80 in U-NII 5&8 Radiated Emission ax20 Note 1: The worst-case mode in all data rates has been determined during the pre-scan, only the test data of the worst-case were recorded in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 10 of 44 REPORT No.SZ25020263W05 Operation and Transmitter Power Level Setting The EUT was tested while in a continues transmitter/receiver mode under the control of tool which is provided by manufacturer, all the items of transmitter were tested under the power setting as below: Modulation Technology OFDMA (802.11ax (HE20)) OFDMA (802.11ax (HE40)) OFDMA (802.11ax (HE80)) Power Setting (U-NII 5/6/7/8) ANT 1 ANT 2 9/9/8/6 8/8/8/5 10/10/10/6 9/9/9/7 13/13/13/12 13/13/13/12 Test Conditions Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa) 15-35 30-60 86-106 MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 11 of 44 Test Setup Layout Diagram Conducted Emission Measurement REPORT No.SZ25020263W05 Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 12 of 44 2) For radiated emissions from 30MHz to1GHz REPORT No.SZ25020263W05 3) For radiated emissions above 1GHz MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 13 of 44 REPORT No.SZ25020263W05 Description of Test Items and Results Conducted Emission Requirement According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN). Frequency Range (MHz) Conducted Limit (dBµV) Quai-peak Average 0.15 - 0.50 66 to 56 56 to 46 0.50 - 5 56 46 5 - 30 60 50 Note: (a) The lower limit shall apply at the band edges. (b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz. Test Procedures The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10. Test Setup Layout Refer to chapter 2.6.2 in this report. Test Result Refer to Annex A.1 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 14 of 44 Restricted Frequency Bands REPORT No.SZ25020263W05 Requirement Radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), should comply with the radiated emission limits specified in Section 15.209(a) (below table). Frequency (MHz) 0.009 - 0.490 0.490 - 1.705 1.705 - 30.0 30 - 88 88 - 216 216 - 960 Above 960 Field Strength (µV/m) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 500 Measurement Distance (m) 300 30 30 3 3 3 3 The following formula is used to convert the equipment isotropic radiated power(e.i.r.p.) to field strength (dBµV/m): Unwanted emissions below 1 GHz must comply with the general field strength limits set forth in § 15.209. According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the above table. For Above 1000MHz, the emission limit in above is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. Test Procedures The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 15 of 44 REPORT No.SZ25020263W05 KDB 789033 Section H) 3)5)6(d)) was used in order to prove compliance For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength. Test Setup Layout Refer to chapter 2.6.3 in this report. Test Result Refer to Annex A.2 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 16 of 44 Radiated Emission REPORT No.SZ25020263W05 Requirement For transmitters operating within the 5.9257.125 GHz band: Any emissions outside of the 5.925 7.125 GHz band must not exceed an e.i.r.p. of -27 dBm/MHz. The following formula is used to convert the equipment isotropic radiated power(e.i.r.p.) to field strength (dBµV/m); Unwanted emissions below 1 GHz must comply with the general field strength limits set forth in § 15.209. According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) 0.009 - 0.490 0.490 - 1.705 1.705 - 30.0 30 - 88 88 - 216 216 - 960 Above 960 Field Strength (µV/m) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 500 Measurement Distance (m) 300 30 30 3 3 3 3 For Above 1000MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit. Test Procedures The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 17 of 44 REPORT No.SZ25020263W05 distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode. For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector. For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak. For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements. The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response. Test Setup Layout Refer to chapter 2.6.3 in this report. Test Result Refer to Annex A.3 in this report. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 18 of 44 REPORT No.SZ25020263W05 Annex A Test Data and Result A.1. Conducted Emission The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be remeasured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT+TV+HDMl cable+Load+Fiber box+Mobile phone+Audio+U disk+WIFI TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 19 of 44 B. Test Plot: REPORT No.SZ25020263W05 (L Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1545 52.42 33.26 2 0.3885 50.62 30.68 3 0.5685 38.35 25.09 4 2.3865 25.04 17.43 5 8.5112 32.73 17.23 6 18.2435 39.80 36.17 Limit (dBµV) Quai-peak 65.75 58.10 56.00 56.00 60.00 60.00 Average 55.75 48.10 46.00 46.00 50.00 50.00 Power-line Verdict PASS PASS Line PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 20 of 44 REPORT No.SZ25020263W05 (N Phase) No. Fre. (MHz) Emission Level (dBµV) Quai-peak Average 1 0.1635 54.09 32.39 2 0.2130 57.28 40.57 3 0.2805 50.94 35.92 4 0.3525 51.80 36.61 5 0.3975 49.25 31.93 6 0.6180 37.90 25.14 Limit (dBµV) Quai-peak 65.28 63.09 60.80 58.90 57.90 56.00 Average 55.28 53.09 50.80 48.90 47.90 46.00 Power-line Verdict Neutral PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 21 of 44 REPORT No.SZ25020263W05 A.2. Restricted Frequency Bands Note 1: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (Horizontal) was recorded in this test report. Note 2: Restricted Frequency Bands were performed in X, Y, Z axis direction, and only the worst axis (X axis) test condition was recorded in this test report. Note 3: All test modes and bandwidth were considered and evaluated respectively by performing full test, only the worst data were recorded. 802.11ax (HEW20) Mode Plot for Channel 1 Fre. (MHz) 5753.19 5753.19 5784.06 5812.59 5875.27 5924.38 Reading [dBV] 40.0 27.4 40.6 27.2 26.9 38.5 Level [dBV/m] 49.64 37.00 50.25 37.13 36.99 48.43 Factor [dB/m] 9.640 9.640 9.680 9.890 10.090 9.920 Limit [dBV/m] 88.23 68.23 88.23 68.23 68.23 88.23 Margin [dB] 38.59 31.23 37.98 31.10 31.24 39.80 Height [cm] 150 150 150 150 150 150 Angle [°] 191 191 212 343 9 283 Detector PK AV PK AV AV PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 22 of 44 Plot for Channel 233 REPORT No.SZ25020263W05 Fre. (MHz) 7125.02 7125.28 7125.28 7125.41 7125.89 7130.98 7291.23 Reading [dBV] 52.1 62.5 62.5 45.5 47.8 29.2 38.1 Level [dBV/m] 65.19 75.61 75.61 58.57 60.92 42.34 51.56 Factor [dB/m] 13.110 13.110 13.110 13.110 13.120 13.160 13.490 Limit [dBV/m] 68.23 88.23 88.23 68.23 88.23 68.23 74.00 Margin [dB] 3.04 12.62 12.62 9.66 27.31 25.89 22.44 Height [cm] 150 150 150 150 150 150 150 Angle [°] 357 246 246 357 81 6 221 Detector AV PK PK AV PK AV PK Verdict PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 23 of 44 802.11ax (HEW40) Mode Plot for Channel 3 REPORT No.SZ25020263W05 Fre. (MHz) 5689.11 5697.53 5845.80 5870.59 5920.17 5924.38 Reading [dBV] 26.3 39.1 26.0 38.5 42.5 28.3 Level [dBV/m] 35.22 48.00 36.38 48.63 52.41 38.24 Factor [dB/m] 8.910 8.880 10.390 10.150 9.880 9.920 Limit [dBV/m] 68.23 88.23 68.23 88.23 88.23 68.23 Margin [dB] 33.01 40.23 31.85 39.60 35.82 29.99 Height [cm] 150 150 150 150 150 150 Angle [°] 357 219 291 0 86 209 Detector AV PK AV PK PK AV Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 24 of 44 Plot for Channel 227 REPORT No.SZ25020263W05 Fre. (MHz) 7086.07 7127.24 7133.57 7250.21 7500.37 7500.37 Reading [dBV] 80.0 46.1 44.8 26.8 39.0 27.8 Level [dBV/m] 92.87 59.19 58.00 39.88 52.02 40.81 Factor [dB/m] 12.850 13.130 13.180 13.120 12.980 12.980 Limit [dBV/m] 88.23 88.23 54.00 74.00 54.00 Margin [dB] 29.04 30.23 14.12 21.98 13.19 Height [cm] 150 150 150 150 150 150 Angle [°] 350 354 350 4 354 142 Detector PK PK PK AV PK AV Verdict NA PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 25 of 44 802.11ax (HEW80) Mode Plot for Channel 7 REPORT No.SZ25020263W05 Fre. (MHz) 5796.69 5812.59 5863.57 5879.01 5918.76 5921.10 Reading [dBV] 47.7 33.5 49.4 36.3 54.1 41.7 Level [dBV/m] 57.43 43.38 59.65 46.31 63.95 51.61 Factor [dB/m] 9.700 9.890 10.260 10.030 9.870 9.890 Limit [dBV/m] 88.23 68.23 88.23 68.23 88.23 68.23 Margin [dB] 30.80 24.85 28.58 21.92 24.28 16.62 Height [cm] 150 150 150 150 150 150 Angle [°] 207 115 207 207 207 207 Detector PK AV PK AV PK AV Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 26 of 44 Plot for Channel 215 REPORT No.SZ25020263W05 Fre. (MHz) 7128.82 7128.82 7234.90 7252.85 7389.54 7425.95 Reading [dBV] 30.0 45.0 28.5 38.7 25.9 39.0 Level [dBV/m] 43.18 58.13 41.82 51.80 39.18 51.99 Factor [dB/m] 13.140 13.140 13.280 13.140 13.240 12.950 Limit [dBV/m] 68.23 88.23 68.23 74.00 54.00 74.00 Margin [dB] 25.05 30.10 26.41 22.20 14.82 22.01 Height [cm] 150 150 150 150 150 150 Angle [°] 357 351 197 96 189 289 Detector AV PK AV PK AV PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 27 of 44 REPORT No.SZ25020263W05 A.3. Radiated Emission According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform a quasi-peak measurement (or average). The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 40GHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note 4: All test modes, bandwidth and channel were considered and evaluated respectively by performing full test, only the worst data were recorded. MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 28 of 44 802.11ax (HEW20) Mode Plot for Channel 45 REPORT No.SZ25020263W05 Fre. (MHz) 36.31 61.41 120.10 143.38 307.21 749.95 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 52.8 63.6 55.3 58.7 56.2 44.2 Level [dBV/m] 23.28 34.89 24.75 27.22 30.92 29.31 Factor [dB/m] -29.500 -28.710 -30.510 -31.460 -25.240 -14.840 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 16.72 5.11 18.75 16.28 15.08 16.69 Height [cm] 150 150 150 150 150 150 Angle [°] 128 0 99 28 110 0 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 29 of 44 REPORT No.SZ25020263W05 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1120.87 1140.01 1818.59 1831.19 3034.34 3120.67 7467.50 7515.57 9982.00 9998.19 13605.03 13621.22 Reading [dBV] 54.4 44.6 38.1 47.6 31.2 40.5 35.2 24.2 43.8 32.6 37.8 27.9 Level [dBV/m] 52.45 42.80 39.55 49.16 39.68 49.33 61.36 50.47 53.84 42.91 54.81 44.76 Factor [dB/m] -1.990 -1.840 1.470 1.560 8.450 8.840 26.180 26.240 10.060 10.350 17.060 16.910 Limit [dBV/m] 74.00 54.00 68.23 88.23 68.23 88.23 74.00 54.00 88.23 68.23 88.23 68.23 Margin [dB] 21.55 11.20 28.68 39.07 28.55 38.90 12.64 3.53 34.39 25.32 33.42 23.47 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 79 68 122 122 360 14 132 58 7 304 32 32 Detector PK AV AV PK AV PK PK AV PK AV PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 30 of 44 REPORT No.SZ25020263W05 Fre. (MHz) 39.70 72.20 121.07 211.05 307.21 749.95 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 58.8 58.0 61.9 54.8 53.8 50.3 Level [dBV/m] 30.02 26.44 31.29 25.44 28.58 35.47 Factor [dB/m] -28.820 -31.540 -30.640 -29.390 -25.240 -14.840 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 9.98 13.56 12.21 18.06 17.42 10.53 Height [cm] 150 150 150 150 150 150 Angle [°] 192 62 359 221 86 121 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 31 of 44 REPORT No.SZ25020263W05 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1163.81 1175.95 1865.72 1890.46 5386.96 5421.96 7206.61 7208.95 11478.74 11504.45 17209.01 17212.34 Reading [dBV] 42.8 52.3 48.0 37.1 36.4 25.2 24.3 35.1 39.4 29.7 37.5 27.5 Level [dBV/m] 41.29 50.97 49.85 39.11 54.27 43.10 50.44 61.12 53.61 43.99 53.49 43.46 Factor [dB/m] -1.510 -1.290 1.820 2.010 17.920 17.900 26.100 26.060 14.250 14.270 15.950 15.920 Limit [dBV/m] 54.00 74.00 88.23 68.23 74.00 54.00 68.23 88.23 74.00 54.00 88.23 68.23 Margin [dB] 12.71 23.03 38.38 29.12 19.73 10.90 17.79 27.11 20.39 10.01 34.74 24.77 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 109 109 163 152 185 326 120 356 355 355 0 12 Detector AV PK PK AV PK AV AV PK PK AV PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 32 of 44 Plot for Channel 105 REPORT No.SZ25020263W05 Fre. (MHz) 36.31 61.53 120.71 144.47 307.21 749.95 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 52.2 62.2 58.6 60.7 55.8 42.3 Level [dBV/m] 22.70 33.57 28.00 29.37 30.58 27.46 Factor [dB/m] -29.500 -28.670 -30.570 -31.340 -25.240 -14.840 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 17.30 6.43 15.50 14.13 15.42 18.54 Height [cm] 150 150 150 150 150 150 Angle [°] 351 4 351 25 119 232 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 33 of 44 REPORT No.SZ25020263W05 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1137.21 1146.54 1809.72 1824.65 3039.94 3097.81 7197.75 7472.16 9982.00 9987.24 13553.12 13660.27 Reading [dBV] 44.2 54.4 37.5 47.5 31.6 41.2 24.5 34.8 44.6 32.6 27.5 38.1 Level [dBV/m] 42.30 52.61 38.92 49.03 40.06 49.86 50.64 61.03 54.64 42.75 44.54 54.61 Factor [dB/m] -1.870 -1.790 1.400 1.510 8.460 8.690 26.180 26.210 10.060 10.160 17.090 16.550 Limit [dBV/m] 54.00 74.00 68.23 88.23 68.23 88.23 68.23 74.00 88.23 68.23 68.23 88.23 Margin [dB] 11.70 21.39 29.31 39.20 28.17 38.37 17.59 12.97 33.59 25.48 23.69 33.62 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 58 68 111 122 359 360 218 337 2 2 164 74 Detector AV PK AV PK AV PK AV PK PK AV AV PK Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 34 of 44 REPORT No.SZ25020263W05 Fre. (MHz) 31.70 61.41 120.71 211.90 307.21 626.75 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 63.7 64.2 61.5 53.8 53.4 47.1 Level [dBV/m] 33.13 35.45 30.88 24.56 28.19 29.83 Factor [dB/m] -30.550 -28.710 -30.570 -29.270 -25.240 -17.310 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 6.87 4.55 12.62 18.94 17.81 16.17 Height [cm] 150 150 150 150 150 150 Angle [°] 66 238 351 3 66 238 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 35 of 44 REPORT No.SZ25020263W05 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1120.87 1163.34 1856.86 1866.19 2319.35 2328.69 7481.03 7481.97 9979.14 9985.33 13616.46 13621.70 Reading [dBV] 53.4 43.1 37.4 47.0 33.2 44.1 35.0 24.3 43.1 32.5 38.5 27.7 Level [dBV/m] 51.39 41.58 39.12 48.85 38.25 49.27 61.31 50.63 53.14 42.59 55.45 44.60 Factor [dB/m] -1.990 -1.520 1.750 1.820 5.030 5.130 26.280 26.290 10.020 10.120 16.960 16.900 Limit [dBV/m] 74.00 54.00 68.23 88.23 54.00 74.00 74.00 54.00 88.23 68.23 88.23 68.23 Margin [dB] 22.61 12.42 29.11 39.38 15.75 24.73 12.69 3.37 35.09 25.64 32.78 23.63 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 152 110 152 142 164 164 282 35 2 128 305 61 Detector PK AV AV PK AV PK PK AV PK AV PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 36 of 44 Plot for Channel 149 REPORT No.SZ25020263W05 Fre. (MHz) 36.31 62.26 120.95 147.51 307.21 749.95 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 52.0 59.3 56.4 58.1 56.0 42.7 Level [dBV/m] 22.47 30.65 25.76 26.31 30.71 27.88 Factor [dB/m] -29.500 -28.660 -30.590 -31.800 -25.240 -14.840 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 17.53 9.35 17.74 17.19 15.29 18.12 Height [cm] 150 150 150 150 150 150 Angle [°] 104 304 360 51 110 175 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 37 of 44 REPORT No.SZ25020263W05 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1137.21 1150.28 1816.72 1821.39 3019.40 3027.34 7187.95 7200.55 9991.05 9999.14 13564.55 13589.79 Reading [dBV] 44.5 54.6 37.4 47.9 41.6 31.3 35.7 24.2 43.7 32.9 38.2 27.8 Level [dBV/m] 42.60 52.84 38.84 49.43 50.05 39.77 61.80 50.36 53.94 43.27 55.32 44.89 Factor [dB/m] -1.870 -1.760 1.450 1.490 8.410 8.430 26.120 26.180 10.220 10.370 17.100 17.110 Limit [dBV/m] 54.00 74.00 68.23 88.23 88.23 68.23 88.23 68.23 88.23 68.23 88.23 68.23 Margin [dB] 11.40 21.16 29.39 38.80 38.18 28.46 26.43 17.87 34.29 24.96 32.91 23.34 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 67 78 121 121 14 14 273 229 61 2 100 215 Detector AV PK AV PK PK AV PK AV PK AV PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 38 of 44 REPORT No.SZ25020263W05 Fre. (MHz) 30.73 52.19 121.31 213.84 249.97 750.07 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 63.4 63.9 62.4 53.9 56.9 50.7 Level [dBV/m] 32.70 35.98 31.64 24.86 29.40 35.81 Factor [dB/m] -30.740 -27.930 -30.790 -29.000 -27.490 -14.840 Limit [dBV/m] 40.00 40.00 43.50 43.50 46.00 46.00 Margin [dB] 7.30 4.02 11.86 18.64 16.60 10.19 Height [cm] 150 150 150 150 150 150 Angle [°] 204 358 334 181 334 92 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 39 of 44 REPORT No.SZ25020263W05 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1154.48 1163.34 1860.59 1869.92 3816.52 3880.46 7487.57 7590.71 10653.46 10724.89 17263.30 17590.46 Reading [dBV] 52.9 42.9 37.2 46.8 38.1 27.4 24.3 34.5 31.2 41.2 38.0 25.8 Level [dBV/m] 51.17 41.42 38.95 48.63 49.72 39.02 50.61 60.76 43.51 53.44 53.41 43.24 Factor [dB/m] -1.680 -1.520 1.780 1.850 11.650 11.670 26.320 26.230 12.310 12.280 15.410 17.440 Limit [dBV/m] 74.00 54.00 68.23 88.23 74.00 54.00 54.00 74.00 54.00 74.00 88.23 68.23 Margin [dB] 22.83 12.58 29.28 39.60 24.28 14.98 3.39 13.24 10.49 20.56 34.82 24.99 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 109 109 141 163 292 120 45 323 49 242 254 150 Detector PK AV AV PK PK AV AV PK AV PK PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 40 of 44 Plot for Channel 209 REPORT No.SZ25020263W05 Fre. (MHz) 36.31 58.38 83.36 147.99 307.21 749.95 (Antenna Horizontal, 30MHz to 1GHz) Reading [dBV] 52.7 60.3 60.2 59.8 56.1 42.6 Level [dBV/m] 23.24 32.00 28.38 27.90 30.90 27.76 Factor [dB/m] -29.500 -28.270 -31.790 -31.890 -25.240 -14.840 Limit [dBV/m] 40.00 40.00 40.00 43.50 46.00 46.00 Margin [dB] 16.76 8.00 11.62 15.60 15.10 18.24 Height [cm] 150 150 150 150 150 150 Angle [°] 321 345 152 39 116 251 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 41 of 44 REPORT No.SZ25020263W05 (Antenna Horizontal, 1GHz to 18GHz) Fre. (MHz) 1114.81 1115.27 1601.57 1610.44 1968.40 2056.60 7042.80 7207.08 10702.99 11106.34 13549.79 13563.60 Reading [dBV] 53.3 42.7 50.8 41.1 49.7 39.6 35.2 24.2 30.5 41.1 37.6 27.3 Level [dBV/m] 51.35 40.79 50.74 41.06 52.41 43.05 60.62 50.22 42.98 54.62 54.69 44.38 Factor [dB/m] -1.960 -1.950 -0.090 -0.020 2.740 3.410 25.440 26.060 12.480 13.530 17.090 17.090 Limit [dBV/m] 74.00 54.00 74.00 54.00 88.23 68.23 74.00 68.23 54.00 74.00 88.23 68.23 Margin [dB] 22.65 13.21 23.26 12.94 35.82 25.18 13.38 18.01 11.02 19.38 33.54 23.85 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 159 159 192 192 203 203 8 116 251 237 212 107 Detector PK AV PK AV PK AV PK AV AV PK PK AV Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 42 of 44 REPORT No.SZ25020263W05 Fre. (MHz) 52.19 119.98 208.87 307.21 479.29 869.15 (Antenna Vertical, 30MHz to 1GHz) Reading [dBV] 63.7 60.3 57.9 53.4 50.8 40.6 Level [dBV/m] 35.76 29.81 28.38 28.19 29.59 28.16 Factor [dB/m] -27.930 -30.500 -29.500 -25.240 -21.160 -12.410 Limit [dBV/m] 40.00 43.50 43.50 46.00 46.00 46.00 Margin [dB] 4.24 13.69 15.12 17.81 16.41 17.84 Height [cm] 150 150 150 150 150 150 Angle [°] 292 26 192 80 251 121 Detector PK PK PK PK PK PK Verdict PASS PASS PASS PASS PASS PASS MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 43 of 44 REPORT No.SZ25020263W05 (Antenna Vertical, 1GHz to 18GHz) Fre. (MHz) 1112.01 1115.27 1832.59 1835.86 2414.56 2450.96 7222.95 7269.62 10683.94 10699.65 13565.98 13595.50 Reading [dBV] 42.8 54.5 46.4 37.2 33.7 42.4 24.3 35.1 30.8 41.5 27.2 37.6 Level [dBV/m] 40.77 52.50 48.03 38.87 39.53 48.89 50.18 60.60 43.22 54.02 44.31 54.67 Factor [dB/m] -1.980 -1.950 1.630 1.650 5.850 6.470 25.870 25.550 12.450 12.510 17.090 17.110 Limit [dBV/m] 54.00 74.00 88.23 68.23 68.23 88.23 68.23 74.00 54.00 74.00 68.23 88.23 Margin [dB] 13.23 21.50 40.20 29.36 28.70 39.34 18.05 13.40 10.78 19.98 23.92 33.56 Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150 Angle [°] 130 130 64 64 97 97 172 355 68 224 250 359 Detector AV PK PK AV AV PK AV PK AV PK AV PK Verdict PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS END OF REPORT MORLAB Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China Tel: 86-755-36698555 Http://www.morlab.cn Fax: 86-755-36698525 E-mail: service@morlab.cn Page 44 of 44Acrobat Distiller 9.3.2 (Windows)