SZ25020263W05 Linkplay AMP003 WiFi6G U-NII

Morlab

SZ25020263W05 Linkplay AMP003 WiFi6G U-NII

Linkplay Technology Inc. AMP003 WiiM Amp Ultra 2BABF-AMP003 2BABFAMP003 amp003

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8316454
REPORT No.SZ25020263W05
TEST REPORT

APPLICANT

: Linkplay Technology Inc.

PRODUCT NAME : WiiM Amp Ultra

MODEL NAME

: AMP003

BRAND NAME

: WiiM

FCC ID

: 2BABF-AMP003

STANDARD(S)

: 47 CFR Part 15 Subpart E

RECEIPT DATE

: 2025-03-19

TEST DATE

: 2025-04-15 to 2025-05-09

ISSUE DATE

: 2025-05-19

Edited by:

Zeng Xiaoying (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn

Page 1 of 44

REPORT No.SZ25020263W05
DIRECTORY
1. Summary of Test Results 3 1.1. Testing Applied Standards and Methods4 1.2. Test Equipment List 5 1.3. Measurement Uncertainty 7 1.4. Testing Laboratory7 2. General Description 8 2.1. Information of Applicant and Manufacturer 8 2.2. Information of EUT8 2.3. Channel Center Frequency of EUT 9 2.4. Test Configuration of EUT 10 2.5. Test Conditions  11 2.6. Test Setup Layout Diagram  12 3. Description of Test Items and Results  14 3.1. Conducted Emission  14 3.2. Restricted Frequency Bands  15 3.3. Radiated Emission  17 Annex A Test Data and Result  19

Version 1.0

Change History Date 2025-05-19

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 2 of 44

Summary of Test Results

REPORT No.SZ25020263W05

No. Section Description

Test Date

Test Engineer

Result

Method Determination
/Remark

1 15.203

Antenna Requirement

N/A

N/A

N/ANote1

N/A

2

ANSI C63.10

Duty Cycle of the Test Signal

N/A

N/A

N/ANote1

N/A

Conducted

3 15.407(a) Output Power

N/A

and E.I.R.P.

N/A

N/ANote1

N/A

Occupied

4

15.407(a)

Bandwidth and Emission

N/A

N/A

N/ANote1

N/A

Bandwidth

5

15.407(a)

Power Spectral Density

N/A

N/A

N/ANote1

N/A

6 15.407(b) Emission Mask

N/A

N/A

N/ANote1

N/A

7

15.407(d)

Contention Based Protocol

N/A

N/A

N/ANote1

N/A

8

15.407(g)

Frequency Stability

N/A

N/A

N/ANote1

N/A

9 15.207

Conducted Emission

May 09, 2025

Fan Shengquan

PASS

No deviation

Restricted

10 15.407(b) Frequency

Apr. 11, 2025 Gao Jianrou PASS No deviation

Bands

11

15.407(b)

Radiated Emission

Apr. 23, 2025 Gao Jianrou PASS No deviation

Note 1: The test results of all conducted test items please refer to the module IC test report

(Report No.: SZ24040154W05), which issued on Jul. 26, 2024.

Note 2: Additions to, deviation, or exclusions from the method shall be judged in the "method

determination" column of add, deviate or exclude from the specific method shall be explained in

the "Remark" of the above table.

Note 3: When the test result is a critical value, we will use the measurement uncertainty give the

judgment result based on the 95% confidence intervals.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 3 of 44

REPORT No.SZ25020263W05
Testing Applied Standards and Methods

According to the specifications of the manufacturer, the EUT must comply with the requirements of the following standards:

No. Standards or Methods 1 47 CFR Part 15 Subpart E 2 ANSI C63.10 3 KDB 789033 D02 4 KDB 987594 D01 5 KDB 987594 D02 6 KDB 987594 D03
7 KDB 662911 D01

Description FCC Technical Requirements Procedures for Compliance Testing of Unlicensed Wireless Devices Guidelines for compliance testing of U-NII devices General guideline for U-NII 5,6,7,8 bands under Part 15 Subpart E Guidelines for compliance testing of U-NII 6GHz devices Questions and Answers for U-NII 5,6,7,8 bands under Part 15 Subpart E Emissions Testing of Transmitters with Multiple Outputs in the Same Band

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 4 of 44

Test Equipment List

REPORT No.SZ25020263W05

1.2.1 Conducted Emission Test Equipment

Equipment Receiver

Serial No. MY56400093

LISN

8127449

Pulse Limiter (10dB)
RF Coaxial Cable (DC-100MHz)

VTSD 9561 F-B #206
BNC

Type N9038A
NSLK 8127 VTSD 9561-F
MRE04

Manufacturer KEYSIGHT
Schwarzbeck

Cal. Date Due Date 2025.01.06 2026.01.05
2025.01.09 2026.01.08

Schwarzbeck 2024.05.30 2025.05.29

Qualwave

2024.07.02 2025.07.01

1.2.2 List of Software Used
Description JS32-RE
TS+ -[JS32-CE]

Manufacturer Tonscend Tonscend

Software Version 5.0.0 2.5.0.0

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 5 of 44

REPORT No.SZ25020263W05

1.2.3 Radiated Test Equipment

Equipment Signal Analyzer Test Antenna - Bi-
Log Test Antenna -
Loop Test Antenna ­
Horn Test Antenna ­
Horn Preamplifier (10MHz-6GHz) Preamplifier (2GHz-18GHz) Preamplifier (18GHz-40GHz)
RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-18GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-40GHz)
RF Coaxial Cable (DC-18GHz) Anechoic Chamber Anechoic Chamber

Serial No. MY56060145

Type N9020A

9163-519 VULB 9163

1519-022

FMZB1519

01774

BBHA 9120D

BBHA9170 #773 46732
61171/61172
DS77209

BBHA9170
S10M100L38 02
S020180L32 03
DCLNA011840C-S

MRE001

PE330

MRE002 MRE003 22290045 22290046 22120181
N/A N/A

CLU18
CLU18
QA360-40KK-0.5
QA360-40KKF-2
QA500-18NN-5
9m*6m*6m
9m*6m*6m

Manufacturer Agilent
Schwarzbeck Schwarzbeck Schwarzbeck Schwarzbeck LUCIX CORP. LUCIX CORP.
Decentest
Pasternack
Pasternack Pasternack Qualwave Qualwave Qualwave
CRT CRT

Cal. Date 2024.05.30 2024.06.22 2024.06.03 2024.06.22 2024.06.22 2024.05.30 2024.05.30 2024.05.30
2024.05.30
2024.05.30 2024.05.30 2024.07.03 2024.07.03 2024.07.03 2025.04.19 2022.11.30

Due Date 2025.05.29 2025.06.21 2025.06.02 2025.06.21 2025.06.21 2025.05.29 2025.05.29 2025.05.29
2025.05.29
2025.05.29 2025.05.29 2025.07.02 2025.07.02 2025.07.02 2028.04.18 2025.11.29

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 6 of 44

Measurement Uncertainty

REPORT No.SZ25020263W05

Test Items Restricted Frequency Bands Radiated Emission Conducted Emission
Testing Laboratory

Uncertainty ±5% ±2.95dB ±2.44dB

Remark Confidence levels of 95% Confidence levels of 95% Confidence levels of 95%

Laboratory Name
Laboratory Address
Telephone Facsimile FCC Designation Number FCC Test Firm Registration Number

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525 CN1192
226174

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 7 of 44

General Description

REPORT No.SZ25020263W05

Information of Applicant and Manufacturer

Applicant Applicant Address Manufacturer Manufacturer Address
Information of EUT

Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560 Linkplay Technology Inc. 8000 Jarvis Avenue Suite #130, Newark, CA 94560

Product Name

WiiM Amp Ultra

Sample No.

4#, 25#

Hardware Version

A98D V02+Main Board V02

Software Version

Linkplay.5.2.708867

Modulation Technology

OFDMA

Modulation Mode

802.11ax (HEW20), 802.11ax (HEW40), 802.11ax (HEW80)

U-NII 5 (5925-6425MHz),

U-NII Band

U-NII 6 (6425-6525MHz), U-NII 7 (6525-6875MHz),

U-NII 8 (6875-7125MHz).

U-NII 5 (5955-6415MHz),

Operating Frequency Range

U-NII 6 (6435-6515MHz), U-NII 7 (6535-6855MHz),

U-NII 8 (6875-7115MHz).

Equipment Class

Low Power Device

6ID 6PP 6XD 6CD

Standard Power Device 6SD 6FX 6FC

Antenna Type

PIFA Antenna

Antenna Gain (dBi)

ANT1: 3.51dBi; ANT2: 3.51dBi

Note 1: The test results of all conducted test items please refer to the module FCC test report (Report No.: SZ24040154W05), which issued on Jul. 26, 2024. We only recorded the radiated test

result in this report.

Note 2: The EUT has two antennas that cannot transmit simultaneously. Both of the two antennas were evaluated separately, only the worst test result (ANT2) were recorded in the test report.

Note 3: The dedicated software was used to control the EUT continuous transmission.

Note 4: For more detailed description, please refer to Specification or User's Manual supplied by

the applicant and/or manufacturer.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 8 of 44

Channel Center Frequency of EUT

REPORT No.SZ25020263W05

Channel center frequency of different bandwidths

Channel Center Frequency = 5950MHz + 5 x nch; 1  nch  233

Bandwidth
20MHz 40MHz 80MHz 160MHz

Value of nch
1 + 4(n-1); 1  n  59 3 + 8(n-1); 1  n  29 7 + 16(n-1); 1  n  14 15 + 32(n-1); 1  n  7

Center Frequency of Low Middle and High Channel in each U-NII band

Bandwidth LCH/MCH/HCH

20MHz 40MHz 80MHz

LCH MCH HCH LCH MCH HCH LCH MCH HCH

U-NII 5
1/1/5955 12/45/6175 24/93/6415
1/3/5965 7/51/6205 12/91/6405 1/7/5985 4/55/6225 6/87/6385

n/nch/Frequency@MHz

U-NII 6

U-NII 7

25/97/6435 27/105/6475 29/113/6515 13/99/6445
-/-/14/107/6485
-/-/7/103/6465
-/-/-

30/117/6535 38/149/6695 46/181/6855 16/123/6565 19/147/6685 23/179/6845 9/135/6625 10/151/6705 11/167/6785

U-NII 8
47/185/6875 53/209/6995 59/233/7115 24/187/6885 26/203/6965 29/227/7085 13/199/6945
-/-/14/215/7025

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 9 of 44

Test Configuration of EUT

REPORT No.SZ25020263W05

Modulation Type and Data Rate of EUT

Mode 802.11ax

Bandwidth (MHz)
20/40/80 (HEW20/40/80)

Modulation Technology
OFDMA

Modulation Type BPSK QPSK
16QAM 64QAM 256QAM 1024QAM

Data Rate MSC0~MCS11

Evaluation of The Worst Case

Investigation has been done on all the possible configurations for searching the worst cases. The following table is a list of the test modes shown in this test report.

Test Items

Mode

Conducted Emission

Normal Use

Restricted Frequency Bands

ax80 in U-NII 5&8

Radiated Emission

ax20

Note 1: The worst-case mode in all data rates has been determined during the pre-scan, only the

test data of the worst-case were recorded in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 10 of 44

REPORT No.SZ25020263W05

Operation and Transmitter Power Level Setting

The EUT was tested while in a continues transmitter/receiver mode under the control of tool which is provided by manufacturer, all the items of transmitter were tested under the power setting as below:

Modulation Technology
OFDMA (802.11ax (HE20)) OFDMA (802.11ax (HE40)) OFDMA (802.11ax (HE80))

Power Setting

(U-NII 5/6/7/8)

ANT 1

ANT 2

9/9/8/6

8/8/8/5

10/10/10/6

9/9/9/7

13/13/13/12

13/13/13/12

Test Conditions
Temperature (°C) Relative Humidity (%) Atmospheric Pressure (kPa)

15-35 30-60 86-106

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 11 of 44

Test Setup Layout Diagram
Conducted Emission Measurement

REPORT No.SZ25020263W05

Radiation Measurement 1) For radiated emissions from 9kHz to 30MHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 12 of 44

2) For radiated emissions from 30MHz to1GHz

REPORT No.SZ25020263W05

3) For radiated emissions above 1GHz

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 13 of 44

REPORT No.SZ25020263W05
Description of Test Items and Results

Conducted Emission

Requirement

According to FCC section 15.207, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table, as measured using a 50µH/50 line impedance stabilization network (LISN).

Frequency Range (MHz)

Conducted Limit (dBµV)

Quai-peak

Average

0.15 - 0.50

66 to 56

56 to 46

0.50 - 5

56

46

5 - 30

60

50

Note:

(a) The lower limit shall apply at the band edges.

(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.

Test Procedures
The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal reference ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI C63.10.

Test Setup Layout Refer to chapter 2.6.2 in this report.

Test Result Refer to Annex A.1 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 14 of 44

Restricted Frequency Bands

REPORT No.SZ25020263W05

Requirement

Radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), should comply with the radiated emission limits specified in Section 15.209(a) (below table).

Frequency (MHz) 0.009 - 0.490 0.490 - 1.705 1.705 - 30.0 30 - 88 88 - 216 216 - 960 Above 960

Field Strength (µV/m) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 500

Measurement Distance (m) 300 30 30 3 3 3 3

The following formula is used to convert the equipment isotropic radiated power(e.i.r.p.) to field strength (dBµV/m):

Unwanted emissions below 1 GHz must comply with the general field strength limits set forth in § 15.209. According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the above table.
For Above 1000MHz, the emission limit in above is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit.
Test Procedures
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of the site as factors are calculated to correct the reading.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 15 of 44

REPORT No.SZ25020263W05
KDB 789033 Section H) 3)5)6(d)) was used in order to prove compliance For the Test Antenna: Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground to determine the maximum value of the field strength.
Test Setup Layout Refer to chapter 2.6.3 in this report.
Test Result Refer to Annex A.2 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 16 of 44

Radiated Emission

REPORT No.SZ25020263W05

Requirement
For transmitters operating within the 5.925­7.125 GHz band: Any emissions outside of the 5.925­ 7.125 GHz band must not exceed an e.i.r.p. of -27 dBm/MHz. The following formula is used to convert the equipment isotropic radiated power(e.i.r.p.) to field strength (dBµV/m);

Unwanted emissions below 1 GHz must comply with the general field strength limits set forth in § 15.209. According to FCC section 15.209 (a), except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table:

Frequency (MHz) 0.009 - 0.490 0.490 - 1.705 1.705 - 30.0 30 - 88 88 - 216 216 - 960 Above 960

Field Strength (µV/m) 2400/F(kHz) 24000/F(kHz) 30 100 150 200 500

Measurement Distance (m) 300 30 30 3 3 3 3

For Above 1000MHz, the emission limit in this paragraph is based on measurement instrumentation employing an average detector, measurement using instrumentation with a peak detector function, corresponding to 20dB above the maximum permitted average limit.

Test Procedures

The EUT is placed on a non-conducting table 80 cm above the ground plane for measurement below 1GHz; 1.5 m above the ground plane for measurement above 1GHz.The antenna to EUT

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 17 of 44

REPORT No.SZ25020263W05
distance is 3meters. The EUT is configured in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode.
For measurements below 30MHz, the emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9kHz-90 kHz, 110kHz-490 kHz. Radiated emission limits in these two bands are based on measurements employing an average detector.
For measurements below 1GHz the resolution bandwidth is set to 100kHz for peak detection measurements or 120kHz for quasi-peak detection measurements. Peak detection is used unless otherwise noted as quasi-peak.
For measurements above 1GHz the resolution bandwidth is set to 1MHz, the video band width is set to 3MHz for peak measurements and as applicable for average measurements.
The EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are made with the antenna polarized in both the vertical and the horizontal positions. For measurements above 1 GHz, keeping the measurement antenna aimed at the source of emissions at each frequency of significant emissions, with polarization oriented for maximum response.
Test Setup Layout
Refer to chapter 2.6.3 in this report.
Test Result
Refer to Annex A.3 in this report.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 18 of 44

REPORT No.SZ25020263W05
Annex A Test Data and Result
A.1. Conducted Emission
The maximum conducted interference is searched using Peak (PK), if the emission levels more than the AV and QP limits, and that have narrow margins from the AV and QP limits will be remeasured with AV and QP detectors. Tests for both L phase and N phase lines of the power mains connected to the EUT are performed. Set RBW=9kHz, VBW=30kHz. Refer to recorded points and plots below. Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested respectively, only the results of the worst case AC 120V/60Hz were recorded in this report. A. Test Setup: Test Mode: EUT+TV+HDMl cable+Load+Fiber box+Mobile phone+Audio+U disk+WIFI TX Test voltage: AC 120V/60Hz The measurement results are obtained as below: E [dBV] =UR + LCable loss [dB] + AFactor UR: Receiver Reading AFactor: Voltage division factor of LISN

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 19 of 44

B. Test Plot:

REPORT No.SZ25020263W05

(L Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1545

52.42

33.26

2 0.3885

50.62

30.68

3 0.5685

38.35

25.09

4 2.3865

25.04

17.43

5 8.5112

32.73

17.23

6 18.2435 39.80

36.17

Limit (dBµV)

Quai-peak 65.75 58.10 56.00 56.00 60.00 60.00

Average 55.75 48.10 46.00 46.00 50.00 50.00

Power-line Verdict

PASS

PASS

Line

PASS PASS

PASS

PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 20 of 44

REPORT No.SZ25020263W05

(N Phase)

No.

Fre. (MHz)

Emission Level (dBµV) Quai-peak Average

1 0.1635

54.09

32.39

2 0.2130

57.28

40.57

3 0.2805

50.94

35.92

4 0.3525

51.80

36.61

5 0.3975

49.25

31.93

6 0.6180

37.90

25.14

Limit (dBµV)

Quai-peak 65.28 63.09 60.80 58.90 57.90 56.00

Average 55.28 53.09 50.80 48.90 47.90 46.00

Power-line Verdict

Neutral

PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 21 of 44

REPORT No.SZ25020263W05
A.2. Restricted Frequency Bands
Note 1: Restricted Frequency Bands were performed when antenna was at vertical and horizontal polarity, and only the worse test condition (Horizontal) was recorded in this test report. Note 2: Restricted Frequency Bands were performed in X, Y, Z axis direction, and only the worst axis (X axis) test condition was recorded in this test report. Note 3: All test modes and bandwidth were considered and evaluated respectively by performing full test, only the worst data were recorded. 802.11ax (HEW20) Mode Plot for Channel 1

Fre. (MHz) 5753.19 5753.19 5784.06 5812.59 5875.27 5924.38

Reading [dBV]
40.0 27.4 40.6 27.2 26.9 38.5

Level [dBV/m]
49.64 37.00 50.25 37.13 36.99 48.43

Factor [dB/m] 9.640 9.640 9.680 9.890 10.090 9.920

Limit [dBV/m]
88.23 68.23 88.23 68.23 68.23 88.23

Margin [dB] 38.59 31.23 37.98 31.10 31.24 39.80

Height [cm] 150 150 150 150 150 150

Angle [°] 191 191 212 343 9 283

Detector
PK AV PK AV AV PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 22 of 44

Plot for Channel 233

REPORT No.SZ25020263W05

Fre. (MHz) 7125.02 7125.28 7125.28 7125.41 7125.89 7130.98 7291.23

Reading [dBV]
52.1 62.5 62.5 45.5 47.8 29.2 38.1

Level [dBV/m]
65.19 75.61 75.61 58.57 60.92 42.34 51.56

Factor [dB/m] 13.110 13.110 13.110 13.110 13.120 13.160 13.490

Limit [dBV/m]
68.23 88.23 88.23 68.23 88.23 68.23 74.00

Margin [dB] 3.04 12.62 12.62 9.66 27.31 25.89 22.44

Height [cm] 150 150 150 150 150 150 150

Angle [°] 357 246 246 357 81 6 221

Detector
AV PK PK AV PK AV PK

Verdict
PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 23 of 44

802.11ax (HEW40) Mode Plot for Channel 3

REPORT No.SZ25020263W05

Fre. (MHz) 5689.11 5697.53 5845.80 5870.59 5920.17 5924.38

Reading [dBV]
26.3 39.1 26.0 38.5 42.5 28.3

Level [dBV/m]
35.22 48.00 36.38 48.63 52.41 38.24

Factor [dB/m] 8.910 8.880 10.390 10.150 9.880 9.920

Limit [dBV/m]
68.23 88.23 68.23 88.23 88.23 68.23

Margin [dB] 33.01 40.23 31.85 39.60 35.82 29.99

Height [cm] 150 150 150 150 150 150

Angle [°] 357 219 291 0 86 209

Detector
AV PK AV PK PK AV

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 24 of 44

Plot for Channel 227

REPORT No.SZ25020263W05

Fre. (MHz) 7086.07 7127.24 7133.57 7250.21 7500.37 7500.37

Reading [dBV]
80.0 46.1 44.8 26.8 39.0 27.8

Level [dBV/m]
92.87 59.19 58.00 39.88 52.02 40.81

Factor [dB/m] 12.850 13.130 13.180 13.120 12.980 12.980

Limit [dBV/m]
88.23 88.23 54.00 74.00 54.00

Margin [dB] 29.04 30.23 14.12 21.98 13.19

Height [cm] 150 150 150 150 150 150

Angle [°] 350 354 350 4 354 142

Detector
PK PK PK AV PK AV

Verdict
NA PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 25 of 44

802.11ax (HEW80) Mode Plot for Channel 7

REPORT No.SZ25020263W05

Fre. (MHz) 5796.69 5812.59 5863.57 5879.01 5918.76 5921.10

Reading [dBV]
47.7 33.5 49.4 36.3 54.1 41.7

Level [dBV/m]
57.43 43.38 59.65 46.31 63.95 51.61

Factor [dB/m] 9.700 9.890 10.260 10.030 9.870 9.890

Limit [dBV/m]
88.23 68.23 88.23 68.23 88.23 68.23

Margin [dB] 30.80 24.85 28.58 21.92 24.28 16.62

Height [cm] 150 150 150 150 150 150

Angle [°] 207 115 207 207 207 207

Detector
PK AV PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 26 of 44

Plot for Channel 215

REPORT No.SZ25020263W05

Fre. (MHz) 7128.82 7128.82 7234.90 7252.85 7389.54 7425.95

Reading [dBV]
30.0 45.0 28.5 38.7 25.9 39.0

Level [dBV/m]
43.18 58.13 41.82 51.80 39.18 51.99

Factor [dB/m] 13.140 13.140 13.280 13.140 13.240 12.950

Limit [dBV/m]
68.23 88.23 68.23 74.00 54.00 74.00

Margin [dB] 25.05 30.10 26.41 22.20 14.82 22.01

Height [cm] 150 150 150 150 150 150

Angle [°] 357 351 197 96 189 289

Detector
AV PK AV PK AV PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 27 of 44

REPORT No.SZ25020263W05
A.3. Radiated Emission
According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than amplitudes measured with the quasi-peak (or average) detector, the measurement data from a spectrum analyzer peak detector will represent the worst-case results, if the peak measured value complies with the quasi-peak (or average) limit, it is unnecessary to perform a quasi-peak measurement (or average).
The measurement results are obtained as below: E [dBV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB] AT: Total correction Factor except Antenna UR: Receiver Reading Gpreamp: Preamplifier Gain AFactor: Antenna Factor at 3m During the test, the total correction Factor AT and AFactor were built in test software. Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis test condition was recorded in this test report. Note2: For the frequency, which started from 9kHz to 30MHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note3: For the frequency, which started from 18GHz to 40GHz, was pre-scanned and the result which was 20dB lower than the limit was not recorded. Note 4: All test modes, bandwidth and channel were considered and evaluated respectively by performing full test, only the worst data were recorded.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 28 of 44

802.11ax (HEW20) Mode Plot for Channel 45

REPORT No.SZ25020263W05

Fre. (MHz) 36.31 61.41 120.10 143.38 307.21 749.95

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
52.8 63.6 55.3 58.7 56.2 44.2

Level [dBV/m]
23.28 34.89 24.75 27.22 30.92 29.31

Factor [dB/m] -29.500 -28.710 -30.510 -31.460 -25.240 -14.840

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 16.72 5.11 18.75 16.28 15.08 16.69

Height [cm] 150 150 150 150 150 150

Angle [°] 128 0 99 28 110 0

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 29 of 44

REPORT No.SZ25020263W05

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1120.87 1140.01 1818.59 1831.19 3034.34 3120.67 7467.50 7515.57 9982.00 9998.19 13605.03 13621.22

Reading [dBV]
54.4 44.6 38.1 47.6 31.2 40.5 35.2 24.2 43.8 32.6 37.8 27.9

Level [dBV/m]
52.45 42.80 39.55 49.16 39.68 49.33 61.36 50.47 53.84 42.91 54.81 44.76

Factor [dB/m] -1.990 -1.840 1.470 1.560 8.450 8.840 26.180 26.240 10.060 10.350 17.060 16.910

Limit [dBV/m]
74.00 54.00 68.23 88.23 68.23 88.23 74.00 54.00 88.23 68.23 88.23 68.23

Margin [dB] 21.55 11.20 28.68 39.07 28.55 38.90 12.64 3.53 34.39 25.32 33.42 23.47

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 79 68 122 122 360 14 132 58 7 304 32 32

Detector
PK AV AV PK AV PK PK AV PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 30 of 44

REPORT No.SZ25020263W05

Fre. (MHz) 39.70 72.20 121.07 211.05 307.21 749.95

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
58.8 58.0 61.9 54.8 53.8 50.3

Level [dBV/m]
30.02 26.44 31.29 25.44 28.58 35.47

Factor [dB/m] -28.820 -31.540 -30.640 -29.390 -25.240 -14.840

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 9.98 13.56 12.21 18.06 17.42 10.53

Height [cm] 150 150 150 150 150 150

Angle [°] 192 62 359 221 86 121

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 31 of 44

REPORT No.SZ25020263W05

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1163.81 1175.95 1865.72 1890.46 5386.96 5421.96 7206.61 7208.95 11478.74 11504.45 17209.01 17212.34

Reading [dBV]
42.8 52.3 48.0 37.1 36.4 25.2 24.3 35.1 39.4 29.7 37.5 27.5

Level [dBV/m]
41.29 50.97 49.85 39.11 54.27 43.10 50.44 61.12 53.61 43.99 53.49 43.46

Factor [dB/m] -1.510 -1.290 1.820 2.010 17.920 17.900 26.100 26.060 14.250 14.270 15.950 15.920

Limit [dBV/m]
54.00 74.00 88.23 68.23 74.00 54.00 68.23 88.23 74.00 54.00 88.23 68.23

Margin [dB] 12.71 23.03 38.38 29.12 19.73 10.90 17.79 27.11 20.39 10.01 34.74 24.77

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 109 109 163 152 185 326 120 356 355 355 0 12

Detector
AV PK PK AV PK AV AV PK PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 32 of 44

Plot for Channel 105

REPORT No.SZ25020263W05

Fre. (MHz) 36.31 61.53 120.71 144.47 307.21 749.95

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
52.2 62.2 58.6 60.7 55.8 42.3

Level [dBV/m]
22.70 33.57 28.00 29.37 30.58 27.46

Factor [dB/m] -29.500 -28.670 -30.570 -31.340 -25.240 -14.840

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 17.30 6.43 15.50 14.13 15.42 18.54

Height [cm] 150 150 150 150 150 150

Angle [°] 351 4 351 25 119 232

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 33 of 44

REPORT No.SZ25020263W05

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1137.21 1146.54 1809.72 1824.65 3039.94 3097.81 7197.75 7472.16 9982.00 9987.24 13553.12 13660.27

Reading [dBV]
44.2 54.4 37.5 47.5 31.6 41.2 24.5 34.8 44.6 32.6 27.5 38.1

Level [dBV/m]
42.30 52.61 38.92 49.03 40.06 49.86 50.64 61.03 54.64 42.75 44.54 54.61

Factor [dB/m] -1.870 -1.790 1.400 1.510 8.460 8.690 26.180 26.210 10.060 10.160 17.090 16.550

Limit [dBV/m]
54.00 74.00 68.23 88.23 68.23 88.23 68.23 74.00 88.23 68.23 68.23 88.23

Margin [dB] 11.70 21.39 29.31 39.20 28.17 38.37 17.59 12.97 33.59 25.48 23.69 33.62

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 58 68 111 122 359 360 218 337 2 2 164 74

Detector
AV PK AV PK AV PK AV PK PK AV AV PK

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 34 of 44

REPORT No.SZ25020263W05

Fre. (MHz) 31.70 61.41 120.71 211.90 307.21 626.75

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
63.7 64.2 61.5 53.8 53.4 47.1

Level [dBV/m]
33.13 35.45 30.88 24.56 28.19 29.83

Factor [dB/m] -30.550 -28.710 -30.570 -29.270 -25.240 -17.310

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 6.87 4.55 12.62 18.94 17.81 16.17

Height [cm] 150 150 150 150 150 150

Angle [°] 66 238 351 3 66 238

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 35 of 44

REPORT No.SZ25020263W05

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1120.87 1163.34 1856.86 1866.19 2319.35 2328.69 7481.03 7481.97 9979.14 9985.33 13616.46 13621.70

Reading [dBV]
53.4 43.1 37.4 47.0 33.2 44.1 35.0 24.3 43.1 32.5 38.5 27.7

Level [dBV/m]
51.39 41.58 39.12 48.85 38.25 49.27 61.31 50.63 53.14 42.59 55.45 44.60

Factor [dB/m] -1.990 -1.520 1.750 1.820 5.030 5.130 26.280 26.290 10.020 10.120 16.960 16.900

Limit [dBV/m]
74.00 54.00 68.23 88.23 54.00 74.00 74.00 54.00 88.23 68.23 88.23 68.23

Margin [dB] 22.61 12.42 29.11 39.38 15.75 24.73 12.69 3.37 35.09 25.64 32.78 23.63

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 152 110 152 142 164 164 282 35 2 128 305 61

Detector
PK AV AV PK AV PK PK AV PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 36 of 44

Plot for Channel 149

REPORT No.SZ25020263W05

Fre. (MHz) 36.31 62.26 120.95 147.51 307.21 749.95

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
52.0 59.3 56.4 58.1 56.0 42.7

Level [dBV/m]
22.47 30.65 25.76 26.31 30.71 27.88

Factor [dB/m] -29.500 -28.660 -30.590 -31.800 -25.240 -14.840

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 17.53 9.35 17.74 17.19 15.29 18.12

Height [cm] 150 150 150 150 150 150

Angle [°] 104 304 360 51 110 175

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 37 of 44

REPORT No.SZ25020263W05

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1137.21 1150.28 1816.72 1821.39 3019.40 3027.34 7187.95 7200.55 9991.05 9999.14 13564.55 13589.79

Reading [dBV]
44.5 54.6 37.4 47.9 41.6 31.3 35.7 24.2 43.7 32.9 38.2 27.8

Level [dBV/m]
42.60 52.84 38.84 49.43 50.05 39.77 61.80 50.36 53.94 43.27 55.32 44.89

Factor [dB/m] -1.870 -1.760 1.450 1.490 8.410 8.430 26.120 26.180 10.220 10.370 17.100 17.110

Limit [dBV/m]
54.00 74.00 68.23 88.23 88.23 68.23 88.23 68.23 88.23 68.23 88.23 68.23

Margin [dB] 11.40 21.16 29.39 38.80 38.18 28.46 26.43 17.87 34.29 24.96 32.91 23.34

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 67 78 121 121 14 14 273 229 61 2 100 215

Detector
AV PK AV PK PK AV PK AV PK AV PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 38 of 44

REPORT No.SZ25020263W05

Fre. (MHz) 30.73 52.19 121.31 213.84 249.97 750.07

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
63.4 63.9 62.4 53.9 56.9 50.7

Level [dBV/m]
32.70 35.98 31.64 24.86 29.40 35.81

Factor [dB/m] -30.740 -27.930 -30.790 -29.000 -27.490 -14.840

Limit [dBV/m]
40.00 40.00 43.50 43.50 46.00 46.00

Margin [dB] 7.30 4.02 11.86 18.64 16.60 10.19

Height [cm] 150 150 150 150 150 150

Angle [°] 204 358 334 181 334 92

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 39 of 44

REPORT No.SZ25020263W05

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1154.48 1163.34 1860.59 1869.92 3816.52 3880.46 7487.57 7590.71 10653.46 10724.89 17263.30 17590.46

Reading [dBV]
52.9 42.9 37.2 46.8 38.1 27.4 24.3 34.5 31.2 41.2 38.0 25.8

Level [dBV/m]
51.17 41.42 38.95 48.63 49.72 39.02 50.61 60.76 43.51 53.44 53.41 43.24

Factor [dB/m] -1.680 -1.520 1.780 1.850 11.650 11.670 26.320 26.230 12.310 12.280 15.410 17.440

Limit [dBV/m]
74.00 54.00 68.23 88.23 74.00 54.00 54.00 74.00 54.00 74.00 88.23 68.23

Margin [dB] 22.83 12.58 29.28 39.60 24.28 14.98 3.39 13.24 10.49 20.56 34.82 24.99

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 109 109 141 163 292 120 45 323 49 242 254 150

Detector
PK AV AV PK PK AV AV PK AV PK PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 40 of 44

Plot for Channel 209

REPORT No.SZ25020263W05

Fre. (MHz) 36.31 58.38 83.36 147.99 307.21 749.95

(Antenna Horizontal, 30MHz to 1GHz)

Reading [dBV]
52.7 60.3 60.2 59.8 56.1 42.6

Level [dBV/m]
23.24 32.00 28.38 27.90 30.90 27.76

Factor [dB/m] -29.500 -28.270 -31.790 -31.890 -25.240 -14.840

Limit [dBV/m]
40.00 40.00 40.00 43.50 46.00 46.00

Margin [dB] 16.76 8.00 11.62 15.60 15.10 18.24

Height [cm] 150 150 150 150 150 150

Angle [°] 321 345 152 39 116 251

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 41 of 44

REPORT No.SZ25020263W05

(Antenna Horizontal, 1GHz to 18GHz)

Fre. (MHz) 1114.81 1115.27 1601.57 1610.44 1968.40 2056.60 7042.80 7207.08 10702.99 11106.34 13549.79 13563.60

Reading [dBV]
53.3 42.7 50.8 41.1 49.7 39.6 35.2 24.2 30.5 41.1 37.6 27.3

Level [dBV/m]
51.35 40.79 50.74 41.06 52.41 43.05 60.62 50.22 42.98 54.62 54.69 44.38

Factor [dB/m] -1.960 -1.950 -0.090 -0.020 2.740 3.410 25.440 26.060 12.480 13.530 17.090 17.090

Limit [dBV/m]
74.00 54.00 74.00 54.00 88.23 68.23 74.00 68.23 54.00 74.00 88.23 68.23

Margin [dB] 22.65 13.21 23.26 12.94 35.82 25.18 13.38 18.01 11.02 19.38 33.54 23.85

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 159 159 192 192 203 203 8 116 251 237 212 107

Detector
PK AV PK AV PK AV PK AV AV PK PK AV

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 42 of 44

REPORT No.SZ25020263W05

Fre. (MHz) 52.19 119.98 208.87 307.21 479.29 869.15

(Antenna Vertical, 30MHz to 1GHz)

Reading [dBV]
63.7 60.3 57.9 53.4 50.8 40.6

Level [dBV/m]
35.76 29.81 28.38 28.19 29.59 28.16

Factor [dB/m] -27.930 -30.500 -29.500 -25.240 -21.160 -12.410

Limit [dBV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] 4.24 13.69 15.12 17.81 16.41 17.84

Height [cm] 150 150 150 150 150 150

Angle [°] 292 26 192 80 251 121

Detector
PK PK PK PK PK PK

Verdict
PASS PASS PASS PASS PASS PASS

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 43 of 44

REPORT No.SZ25020263W05

(Antenna Vertical, 1GHz to 18GHz)

Fre. (MHz) 1112.01 1115.27 1832.59 1835.86 2414.56 2450.96 7222.95 7269.62 10683.94 10699.65 13565.98 13595.50

Reading [dBV]
42.8 54.5 46.4 37.2 33.7 42.4 24.3 35.1 30.8 41.5 27.2 37.6

Level [dBV/m]
40.77 52.50 48.03 38.87 39.53 48.89 50.18 60.60 43.22 54.02 44.31 54.67

Factor [dB/m] -1.980 -1.950 1.630 1.650 5.850 6.470 25.870 25.550 12.450 12.510 17.090 17.110

Limit [dBV/m]
54.00 74.00 88.23 68.23 68.23 88.23 68.23 74.00 54.00 74.00 68.23 88.23

Margin [dB] 13.23 21.50 40.20 29.36 28.70 39.34 18.05 13.40 10.78 19.98 23.92 33.56

Height [cm] 150 150 150 150 150 150 150 150 150 150 150 150

Angle [°] 130 130 64 64 97 97 172 355 68 224 250 359

Detector
AV PK PK AV AV PK AV PK AV PK AV PK

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

END OF REPORT

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL.1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: service@morlab.cn
Page 44 of 44


Acrobat Distiller 9.3.2 (Windows)