Test report

Mapleprint Inc PL80E Bluetooth Thermal Label Printer 2A4KN-PL80E 2A4KNPL80E pl80e

PDF preview unavailable. Download the PDF instead.

GetApplicationAttachment.html?id=8035358
## Page 1 of 32

FCC Test Report

Report No.

: 1812C40184012501

Applicant

: Mapleprint Inc

Address

:

140 58TH STREET BLDG A DOCK 4A BROOKLYN, NY 11220 United States

Product Name : Bluetooth Thermal Label Printer

Report Date : Jan. 22, 2025

##
Shenzhen Anbotek Compliance Laboratory Limited

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 2 of 32

Contents
1. General Information ...............................................................................................................................6
1.1. Client Information ........................................................................................................................6 1.2. Description of Device (EUT) ........................................................................................................6 1.3. Auxiliary Equipment Used During Test........................................................................................7 1.4. Operation channel list..................................................................................................................7 1.5. Description of Test Modes...........................................................................................................7 1.6. Measurement Uncertainty ...........................................................................................................8 1.7. Test Summary .............................................................................................................................8 1.8. Description of Test Facility ..........................................................................................................9 1.9. Disclaimer....................................................................................................................................9 1.10. Test Equipment List.................................................................................................................10
2. Antenna requirement ...........................................................................................................................12
2.1. Conclusion.................................................................................................................................12
3. Conducted Emission at AC power line ................................................................................................13
3.1. EUT Operation ..........................................................................................................................13 3.2. Test Setup .................................................................................................................................13 3.3. Test Data ...................................................................................................................................14
4. 6dB Bandwidth ....................................................................................................................................16
4.1. EUT Operation ..........................................................................................................................16 4.2. Test Setup .................................................................................................................................16 4.3. Test Data ...................................................................................................................................16
5. Maximum Conducted Output Power....................................................................................................17
5.1. EUT Operation ..........................................................................................................................17 5.2. Test Setup .................................................................................................................................17 5.3. Test Data ...................................................................................................................................17
6. Power Spectral Density .......................................................................................................................18
6.1. EUT Operation ..........................................................................................................................18 6.2. Test Setup .................................................................................................................................18 6.3. Test Data ...................................................................................................................................18
7. Emissions in non-restricted frequency bands......................................................................................19
7.1. EUT Operation ..........................................................................................................................19 7.2. Test Setup .................................................................................................................................19 7.3. Test Data ...................................................................................................................................19
8. Band edge emissions (Radiated) ........................................................................................................20
8.1. EUT Operation ..........................................................................................................................20 8.2. Test Setup .................................................................................................................................21 8.3. Test Data ...................................................................................................................................22
9. Emissions in frequency bands (below 1GHz)......................................................................................23
9.1. EUT Operation ..........................................................................................................................23 9.2. Test Setup .................................................................................................................................24 9.3. Test Data ...................................................................................................................................25
10. Emissions in frequency bands (above 1GHz) ...................................................................................27
10.1. EUT Operation ........................................................................................................................27

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 3 of 32

10.2. Test Setup ...............................................................................................................................28 10.3. Test Data .................................................................................................................................29
APPENDIX I -- TEST SETUP PHOTOGRAPH .......................................................................................32 APPENDIX II -- EXTERNAL PHOTOGRAPH .........................................................................................32 APPENDIX III -- INTERNAL PHOTOGRAPH..........................................................................................32

Applicant Manufacturer Product Name Model No. Trade Mark Rating(s)

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E
TEST REPORT
: Mapleprint Inc : Zhongshan Polono Electronic Technology Co., Ltd. : Bluetooth Thermal Label Printer : PL80E : POLONO : Input: 24V2.5A

Page 4 of 32

Test Standard(s)

47 CFR Part 15.247 : KDB 558074 D01 15.247 Meas Guidance v05r02
ANSI C63.10-2020

The device described above is tested by Shenzhen Anbotek Compliance Laboratory Limited to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The measurement results are contained in this test report and Shenzhen Anbotek Compliance Laboratory Limited is assumed full of responsibility for the accuracy and completeness of these measurements. Also, this report shows that the EUT (Equipment Under Test) is technically compliant with above listed standard(s) requirements. This report applies to above tested sample only and shall not be reproduced in part without written approval of Shenzhen Anbotek Compliance Laboratory Limited.

Date of Receipt: Date of Test:

Dec. 16, 2024 Dec. 16, 2024 to Dec. 27, 2024

Prepared By:

(Cecilia Chen)

Approved & Authorized Signer:

(KingKong Jin)

Report Version R00

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E
Revision History
Description Original Issue.

Page 5 of 32
Issued Date Jan. 22, 2025

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 6 of 32

1. General Information
1.1. Client Information

Applicant Address

: Mapleprint Inc

:

140 58TH STREET BLDG A DOCK 4A BROOKLYN, NY 11220 United States

Manufacturer Address Factory

: Zhongshan Polono Electronic Technology Co., Ltd.

:

No. 132, Tanlong North Road, Tanzhou Town, Zhongshan City, 4th and 5th floors, Building 2, 4th and 5th floors, Building 3, China

: Zhongshan Polono Electronic Technology Co., Ltd.

Address

:

No. 132, Tanlong North Road, Tanzhou Town, Zhongshan City, 4th and 5th floors, Building 2, 4th and 5th floors, Building 3, China

1.2. Description of Device (EUT)

Product Name

: Bluetooth Thermal Label Printer

Model No.

: PL80E

Trade Mark

: POLONO

Test Power Supply : DC 24V from Adapter input AC120V/60Hz

Test Sample No.
Adapter
RF Specification Operation Frequency Number of Channel

: 1-2-1(Normal Sample), 1-2-2(Engineering Sample)

Manufacturer: Hunan Dajing Power Technology Co., Ltd.

:

Model: ADP-60D24 Input: 100-240V~, 50/60Hz, 1.5A MAX

Output: 24.0V2.5A, 60.0W

: 2402MHz to 2480MHz : 40

Modulation Type

: GFSK

Antenna Type

: PCB Antenna

Antenna Gain(Peak) : -0.93dBi
Remark: (1) All of the RF specification are provided by customer. (2) For a more detailed features description, please refer to the manufacturer's specifications or the User's Manual.

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 7 of 32

1.3. Auxiliary Equipment Used During Test

Title

Manufacturer

Model No.

Serial No.

/

/

/

/

1.4. Operation channel list

Operation Band:

Channel

Frequency (MHz)

Channel

0

2402

10

1

2404

11

2

2406

12

3

2408

13

4

2410

14

5

2412

15

6

2414

16

7

2416

17

8

2418

18

9

2420

19

Frequency (MHz) 2422 2424 2426 2428 2430 2432 2434 2436 2438 2440

Channel
20 21 22 23 24 25 26 27 28 29

Frequency (MHz) 2442 2444 2446 2448 2450 2452 2454 2456 2458 2460

Channel
30 31 32 33 34 35 36 37 38 39

Frequency (MHz) 2462 2464 2466 2468 2470 2472 2474 2476 2478 2480

1.5. Description of Test Modes

Pretest Modes TM1 TM2

Descriptions Keep the EUT works in continuously transmitting mode (BLE 1M) Keep the EUT works in continuously transmitting mode (BLE 2M)

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 8 of 32

1.6. Measurement Uncertainty

Parameter

Uncertainty

Conducted emissions (AMN 150kHz~30MHz)

3.4dB

Occupied Bandwidth

925Hz

Conducted Output Power

0.76dB

Duty Cycle

2%

Power Spectral Density

0.76dB

Conducted Spurious Emission

1.24dB

Radiated spurious emissions (above 1GHz)

1G-6GHz: 4.78dB; 6G-18GHz: 4.88dB 18G-40GHz: 5.68dB

Radiated emissions (Below 30MHz)

3.53dB

Radiated spurious emissions (30MHz~1GHz)

Horizontal: 4.46dB; Vertical: 5.04dB

The measurement uncertainty and decision risk evaluated according to AB/WI-RF-F-032. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

1.7. Test Summary

Test Items Antenna requirement Conducted Emission at AC power line 6dB Bandwidth Maximum Conducted Output Power Power Spectral Density Emissions in non-restricted frequency bands Band edge emissions (Radiated) Emissions in frequency bands (below 1GHz) Emissions in frequency bands (above 1GHz) Note: P: Pass N: N/A, not applicable

Test Modes /
Mode1,2 Mode1,2 Mode1,2 Mode1,2 Mode1,2 Mode1,2 Mode1,2 Mode1,2

Status P P P P P P P P P

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 9 of 32

1.8. Description of Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
FCC-Registration No.:434132 Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration No. 434132.
ISED-Registration No.: 8058A Shenzhen Anbotek Compliance Laboratory Limited, EMC Laboratory has been registered and fully described in a report filed with the (ISED) Innovation, Science and Economic Development Canada. The acceptance letter from the ISED is maintained in our files. Registration 8058A.
Test Location Shenzhen Anbotek Compliance Laboratory Limited. Sogood Industrial Zone Laboratory & 1/F. of Building D, Sogood Science and Technology Park, Sanwei Community, Hangcheng Subdistrict, Bao'an District, Shenzhen, Guangdong, China.

1.9. Disclaimer
1. The test report is invalid if not marked with the signatures of the persons responsible for preparing and approving the test report.
2. The test report is invalid if there is any evidence and/or falsification.
3. The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein.
4. This document may not be altered or revised in any way unless done so by Anbotek and all revisions are duly noted in the revisions section.
5. Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes without prior written approval from the laboratory.
6. The authenticity of the information provided by the customer is the responsibility of the customer and the laboratory is not responsible for its authenticity.
The laboratory is only responsible for the data released by the laboratory, except for the part provided by the applicant.

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 10 of 32

1.10. Test Equipment List

Conducted Emission at AC power line

Item Equipment

1

L.I.S.N. Artificial Mains Network

Three Phase V-

2

type Artificial

Power Network

3

Software Name EZ-EMC

4

EMI Test Receiver(CE2#)

Manufacturer Model No. Serial No. Last Cal. Cal.Due Date Rohde & Schwarz ENV216 100055 2024-09-09 2025-09-08

CYBERTEK

EM5040DT

E215040D T001

2024-01-17

2025-01-16

Farad Technology ANB-03A

N/A

/

/

Rohde & Schwarz ESPI3

100926 2024-09-09 2025-09-08

Maximum Conducted Output Power Power Spectral Density Emissions in non-restricted frequency bands 6dB Bandwidth

Item Equipment

Manufacturer

Constant

1

Temperature Humidity

Chamber

ZHONGJIAN

2 DC Power Supply

IVYTECH

3

Spectrum Analyzer

Rohde & Schwarz

4

MXA Spectrum Analysis

KEYSIGHT

5

Oscilloscope

Tektronix

6

MXG RF Vector Signal Generator

Agilent

Model No. Serial No. Last Cal.

ZJKHWS80B

N/A

2024-10-14

IV3605

1804D360 510

2024-09-09

FSV40-N 102150 2024-05-06

N9020A MDO3012 N5182A

MY505318 23
C020298
MY474206 47

2024-09-09 2024-10-10 2024-02-04

Cal.Due Date
2025-10-13
2025-09-08 2025-05-05 2025-09-08 2025-10-09 2025-02-03

Band edge emissions (Radiated) Emissions in frequency bands (above 1GHz)

Item Equipment

Manufacturer

1

EMI Test Receiver(RE2/3#)

Rohde & Schwarz

2 EMI Preamplifier SKET Electronic

3

Double Ridged Horn Antenna

SCHWARZBECK

4

EMI Test Software EZ-EMC

SHURPLE

5 Horn Antenna

A-INFO

6

Spectrum Analyzer

Rohde & Schwarz

7

Amplifier

Talent Microwave

Model No. Serial No.

ESR26 101481

LNPA0118G-45
BBHA 9120D

SKET-PA002
02555

N/A

N/A

LB-180400- J2110606

KF

28

FSV40-N 102150

TLLA18G40 G-50-30

23022802

Last Cal. 2024-01-23 2024-01-17 2022-10-16
/ 2024-01-22 2024-05-06 2024-05-07

Cal.Due Date 2025-01-22 2025-01-16 2025-10-15
/ 2027-01-21 2025-05-05 2025-05-06

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 11 of 32

Emissions in frequency bands (below 1GHz)

Item Equipment

Manufacturer Model No. Serial No.

1

EMI Test Receiver(RE2/3#)

Rohde & Schwarz

ESR26

101481

2

Pre-amplifier

SONOMA

310N

186860

3

Bilog Broadband Antenna

Schwarzbeck

VULB9163

345

4

EMI Preamplifier

SKET Electronic

LNPA- SKET-PA-

0118G-45

002

5

Double Ridged Horn Antenna

SCHWARZBECK

BBHA 9120D

2555

6

Loop Antenna (9K-30M)

Schwarzbeck

FMZB1519 B

00053

7

EMI Test Software EZ-EMC

SHURPLE

N/A

N/A

8

MXA Spectrum Analysis

Agilent

N9020A

MY511700 37

9

MXG RF Vector Signal Generator

Agilent

N5182A

MY481806 56

10 DC Power Supply

LW

TPR-6420D 374470

Constant

11

Temperature Humidity

ZHONGJIAN

ZJKHWS80B

N/A

Chamber

Wideband Radio

12 Communication Rohde & Schwarz CMW 500 167336

Tester

13 High-Pass Filter

CDKMV

ZHPFBM1100-
4730

B2015094 550

14 High-Pass Filter

CDKMV

ZHPF-M3.5- 13070065

18G-3834

23

Last Cal. 2024-01-23 2024-01-17 2022-10-23 2024-01-17 2022-10-16 2024-09-12
/ 2024-09-09 2024-02-04 2024-10-17
2024-10-14
2024-02-04
2024-10-17 2024-10-17

Cal.Due Date 2025-01-22 2025-01-16 2025-10-22 2025-01-16 2025-10-15 2025-09-11
/ 2025-09-08 2025-02-03 2025-10-16
2025-10-13
2025-02-03
2025-10-16 2025-10-16

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 12 of 32

2. Antenna requirement

Test Requirement:

Refer to 47 CFR Part 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section.

2.1. Conclusion
The antenna is a PCB antenna which permanently attached, and the best case gain of the antenna is -0.93dBi. It complies with the standard requirement.

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 13 of 32

3. Conducted Emission at AC power line

Test Requirement:
Test Limit: Test Method: Procedure:

Refer to 47 CFR 15.207(a), Except as shown in paragraphs (b)and (c)of this section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies, within the band 150 kHz to 30 MHz, shall not exceed the limits in the following table, as measured using a 50 H/50 ohms line impedance stabilization network (LISN).

Frequency of emission (MHz)
0.15-0.5 0.5-5 5-30

Conducted limit (dBV)

Quasi-peak

Average

66 to 56*

56 to 46*

56

46

60

50

*Decreases with the logarithm of the frequency.

ANSI C63.10-2020 section 6.2

Refer to ANSI C63.10-2020 section 6.2, standard test method for ac powerline conducted emissions from unlicensed wireless devices

3.1. EUT Operation

Operating Environment:

Test mode:

1: TX mode(BLE 1M): Keep the EUT works in continuously transmitting mode (BLE 1M) 2: TX mode(BLE 2M): Keep the EUT works in continuously transmitting mode (BLE 2M)

3.2. Test Setup

3.3. Test Data

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 14 of 32

Temperature: 23.1 °C

Humidity: 40 %

Atmospheric Pressure: 101 kPa

TM1 / Line: Line / Band: 2400-2483.5 MHz / BW: 1 / CH: M

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 15 of 32

Temperature: 23.1 °C

Humidity: 40 %

Atmospheric Pressure: 101 kPa

TM1 / Line: Neutral / Band: 2400-2483.5 MHz / BW: 1 / CH: M

Note: Only record the worst data in the report.

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 16 of 32

4. 6dB Bandwidth

Test Requirement: Test Limit: Test Method:
Procedure:

47 CFR 15.247(a)(2)
Refer to 47 CFR 15.247(a)(2), Systems using digital modulation techniques may operate in the 902-928 MHz, and 2400-2483.5 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.
ANSI C63.10-2020, section 11.8 KDB 558074 D01 15.247 Meas Guidance v05r02
11.8.1 Option 1 The steps for the first option are as follows: a) Set RBW = shall be in the range of 1% to 5% of the OBW but not less than 100 kHz. b) Set the VBW  [3 × RBW]. c) Detector = peak. d) Trace mode = max-hold. e) Sweep = No faster than coupled (auto) time. f) Allow the trace to stabilize. g) Measure the maximum width of the emission by placing two markers, one at the lowest frequency and the other at the highest frequency of the envelope of the spectral display, such that each marker is at or slightly below the "-6 dB down amplitude". If a marker is below this "-6 dB down amplitude" value, then it shall be as close as possible to this value.

11.8.2 Option 2 The automatic bandwidth measurement capability of an instrument may be employed using the X dB bandwidth mode with X set to 6 dB, if the functionality described in 11.8.1 (i.e., RBW = 100 kHz, VBW  3 × RBW, and peak detector with maximum hold) is implemented by the instrumentation function. When using this capability, care shall be taken so that the bandwidth measurement is not influenced by any intermediate power nulls in the fundamental emission that might be  6 dB.

4.1. EUT Operation

Operating Environment:

Test mode:

1: TX mode(BLE 1M): Keep the EUT works in continuously transmitting mode (BLE 1M) 2: TX mode(BLE 2M): Keep the EUT works in continuously transmitting mode (BLE 2M)

4.2. Test Setup

4.3. Test Data
Temperature: 23.3 °C

Humidity: 53 %

Please Refer to Appendix for Details.

Atmospheric Pressure: 101 kPa

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 17 of 32

5. Maximum Conducted Output Power

Test Requirement:
Test Limit:
Test Method: Procedure:

47 CFR 15.247(b)(3)
Refer to 47 CFR 15.247(b)(3), For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance with the one Watt limit can be based on a measurement of the maximum conducted output power. Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at its maximum power control level. Power must be summed across all antennas and antenna elements. The average must not include any time intervals during which the transmitter is off or is transmitting at a reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods), the maximum conducted output power is the highest total transmit power occurring in any mode.
ANSI C63.10-2020 section 11.9.1 KDB 558074 D01 15.247 Meas Guidance v05r02
ANSI C63.10-2020, section 11.9.1 Maximum peak conducted output power

5.1. EUT Operation

Operating Environment:

Test mode:

1: TX mode(BLE 1M): Keep the EUT works in continuously transmitting mode (BLE 1M) 2: TX mode(BLE 2M): Keep the EUT works in continuously transmitting mode (BLE 2M)

5.2. Test Setup

5.3. Test Data
Temperature: 23.3 °C

Humidity: 53 %

Please Refer to Appendix for Details.

Atmospheric Pressure: 101 kPa

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 18 of 32

6. Power Spectral Density

Test Requirement: Test Limit:
Test Method: Procedure:

47 CFR 15.247(e)
Refer to 47 CFR 15.247(e), For digitally modulated systems, the power spectral density conducted from the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous transmission. This power spectral density shall be determined in accordance with the provisions of paragraph (b) of this section. The same method of determining the conducted output power shall be used to determine the power spectral density.
ANSI C63.10-2020, section 11.10 KDB 558074 D01 15.247 Meas Guidance v05r02
ANSI C63.10-2020, section 11.10, Maximum power spectral density level in the fundamental emission

6.1. EUT Operation

Operating Environment:

Test mode:

1: TX mode(BLE 1M): Keep the EUT works in continuously transmitting mode (BLE 1M) 2: TX mode(BLE 2M): Keep the EUT works in continuously transmitting mode (BLE 2M)

6.2. Test Setup

6.3. Test Data
Temperature: 23.3 °C

Humidity: 53 %

Please Refer to Appendix for Details.

Atmospheric Pressure: 101 kPa

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 19 of 32

7. Emissions in non-restricted frequency bands

Test Requirement:
Test Limit:
Test Method: Procedure:

47 CFR 15.247(d), 15.209, 15.205
Refer to 47 CFR 15.247(d), In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in § 15.209(a) is not required.
ANSI C63.10-2020 section 11.11 KDB 558074 D01 15.247 Meas Guidance v05r02
ANSI C63.10-2020 Section 11.11.1, Section 11.11.2, Section 11.11.3

7.1. EUT Operation

Operating Environment:

Test mode:

1: TX mode(BLE 1M): Keep the EUT works in continuously transmitting mode (BLE 1M) 2: TX mode(BLE 2M): Keep the EUT works in continuously transmitting mode (BLE 2M)

7.2. Test Setup

7.3. Test Data
Temperature: 23.3 °C

Humidity: 53 %

Please Refer to Appendix for Details.

Atmospheric Pressure: 101 kPa

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 20 of 32

8. Band edge emissions (Radiated)

Test Requirement:
Test Limit:
Test Method: Procedure:

Refer to 47 CFR 15.247(d), In addition, radiated emissions which fall in the restricted bands, as defined in § 15.205(a), must also comply with the radiated emission limits specified in § 15.209(a)(see § 15.205(c)).`

Frequency (MHz)
0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960

Field strength (microvolts/meter)
2400/F(kHz) 24000/F(kHz) 30 100 ** 150 ** 200 ** 500

Measurement distance (meters) 300 30 30 3 3 3 3

** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§ 15.231 and 15.241. In the emission table above, the tighter limit applies at the band edges. The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9­ 90 kHz, 110­490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector.

ANSI C63.10-2020 section 6.10 KDB 558074 D01 15.247 Meas Guidance v05r02

ANSI C63.10-2020 section 6.10.5.2

8.1. EUT Operation

Operating Environment:

Test mode:

1: TX mode(BLE 1M): Keep the EUT works in continuously transmitting mode (BLE 1M) 2: TX mode(BLE 2M): Keep the EUT works in continuously transmitting mode (BLE 2M)

8.2. Test Setup

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 21 of 32

8.3. Test Data
Temperature: 23.3 °C

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 22 of 32

Humidity: 53 % TM1 / CH: L

Atmospheric Pressure: 101 kPa

Peak Value(Vertical)

TM1 / CH: H

Peak Value(Horizontal)

Peak Value(Vertical)

Peak Value(Horizontal)

Remark: 1. During the test, pre-scan all modes, the report only record the worse case mode. 2. When the PK measure result value is less than the AVG limit value, the AV measure result values
test not applicable.

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 23 of 32

9. Emissions in frequency bands (below 1GHz)

Test Requirement:
Test Limit:
Test Method: Procedure:

Refer to 47 CFR 15.247(d), In addition, radiated emissions which fall in the restricted bands, as defined in § 15.205(a), must also comply with the radiated emission limits specified in § 15.209(a)(see § 15.205(c)).`

Frequency (MHz)
0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960

Field strength (microvolts/meter)
2400/F(kHz) 24000/F(kHz) 30 100 ** 150 ** 200 ** 500

Measurement distance (meters) 300 30 30 3 3 3 3

** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§ 15.231 and 15.241. In the emission table above, the tighter limit applies at the band edges. The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9­ 90 kHz, 110­490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector.

ANSI C63.10-2020 section 6.6.4 KDB 558074 D01 15.247 Meas Guidance v05r02

ANSI C63.10-2020 section 6.6.4

9.1. EUT Operation

Operating Environment:

Test mode:

1: TX mode(BLE 1M): Keep the EUT works in continuously transmitting mode (BLE 1M) 2: TX mode(BLE 2M): Keep the EUT works in continuously transmitting mode (BLE 2M)

9.2. Test Setup

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 24 of 32

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 25 of 32

9.3. Test Data
The test results of 9kHz-30MHz was attenuated more than 20dB below the permissible limits, so the results don't record in the report.

Temperature: 23.7 °C

Humidity: 52 %

Atmospheric Pressure: 101 kPa

TM1 / Polarization: Horizontal / Band: 2400-2483.5 MHz / BW: 1 / CH: M

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 26 of 32

Temperature: 23.7 °C

Humidity: 52 %

Atmospheric Pressure: 101 kPa

TM1 / Polarization: Vertical / Band: 2400-2483.5 MHz / BW: 1 / CH: M

Note: Only record the worst data in the report.

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 27 of 32

10. Emissions in frequency bands (above 1GHz)

Test Requirement:
Test Limit:
Test Method: Procedure:

In addition, radiated emissions which fall in the restricted bands, as defined in § 15.205(a), must also comply with the radiated emission limits specified in § 15.209(a)(see § 15.205(c)).`

Frequency (MHz)
0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960

Field strength (microvolts/meter)
2400/F(kHz) 24000/F(kHz) 30 100 ** 150 ** 200 ** 500

Measurement distance (meters) 300 30 30 3 3 3 3

** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§ 15.231 and 15.241. In the emission table above, the tighter limit applies at the band edges. The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9­ 90 kHz, 110­490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector.

ANSI C63.10-2020 section 6.6.4 KDB 558074 D01 15.247 Meas Guidance v05r02

ANSI C63.10-2020 section 6.6.4

10.1. EUT Operation

Operating Environment:

Test mode:

1: TX mode(BLE 1M): Keep the EUT works in continuously transmitting mode (BLE 1M) 2: TX mode(BLE 2M): Keep the EUT works in continuously transmitting mode (BLE 2M)

10.2. Test Setup

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 28 of 32

10.3. Test Data
Temperature: 23.4 °C

Peak value:
Frequency (MHz) 4804.00 7206.00 9608.00
12010.00 14412.00 4804.00 7206.00 9608.00 12010.00 14412.00
Average value:
Frequency (MHz) 4804.00 7206.00 9608.00
12010.00 14412.00 4804.00 7206.00 9608.00 12010.00 14412.00

Reading (dBuV) 30.26 30.02 31.49
* * 29.77 31.21 28.89 * *
Reading (dBuV) 18.53 19.07 20.96
* * 18.10 20.24 18.40 * *

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 29 of 32

Humidity: 49 % TM1 / CH: L

Atmospheric Pressure: 101 kPa

Factor (dB/m) 15.27 18.09 23.76
15.27 18.09 23.76

Result (dBuV/m)
45.53 48.11 55.25
45.04 49.30 52.65

Limit (dBuV/m)
74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -28.47 -25.89 -18.75
-28.96 -24.70 -21.35

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Factor (dB/m) 15.27 18.09 23.76
15.27 18.09 23.76

Result (dBuV/m)
33.80 37.16 44.72
33.37 38.33 42.16

Limit (dBuV/m)
54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00

Over Limit (dB) -20.20 -16.84 -9.28
-20.63 -15.67 -11.84

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Peak value:
Frequency (MHz) 4880.00 7320.00 9760.00
12200.00 14640.00 4880.00 7320.00 9760.00 12200.00 14640.00
Average value:
Frequency (MHz) 4880.00 7320.00 9760.00
12200.00 14640.00 4880.00 7320.00 9760.00 12200.00 14640.00

Reading (dBuV) 29.81 29.99 30.99
* * 29.58 31.08 28.61 * *
Reading (dBuV) 18.62 18.93 20.81
* * 18.21 20.59 18.70 * *

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E
TM1 / CH: M

Page 30 of 32

Factor (dB/m) 15.42 18.02 23.80
15.42 18.02 23.80

Result (dBuV/m)
45.23 48.01 54.79
45.00 49.10 52.41

Limit (dBuV/m)
74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -28.77 -25.99 -19.21
-29.00 -24.90 -21.59

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Factor (dB/m) 15.42 18.02 23.80
15.42 18.02 23.80

Result (dBuV/m)
34.04 36.95 44.61
33.63 38.61 42.50

Limit (dBuV/m)
54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00

Over Limit (dB) -19.96 -17.05 -9.39
-20.37 -15.39 -11.50

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E

Page 31 of 32

Peak value: Frequency (MHz) 4960.00 7440.00 9920.00 12400.00 14880.00 4960.00 7440.00 9920.00 12400.00 14880.00
Average value:
Frequency (MHz) 4960.00 7440.00 9920.00
12400.00 14880.00 4960.00 7440.00 9920.00 12400.00 14880.00

Reading (dBuV) 29.94 30.15 31.69
* * 29.72 31.29 28.99 * *
Reading (dBuV) 19.74 20.20 21.46
* * 19.39 21.39 18.85 * *

TM1 / CH: H

Factor (dB/m) 15.58 17.93 23.83
15.58 17.93 23.83

Result (dBuV/m)
45.52 48.08 55.52
45.30 49.22 52.82

Limit (dBuV/m)
74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00 74.00

Over Limit (dB) -28.48 -25.92 -18.48
-28.70 -24.78 -21.18

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Factor (dB/m) 15.58 17.93 23.83
15.58 17.93 23.83

Result (dBuV/m)
35.32 38.13 45.29
34.97 39.32 42.68

Limit (dBuV/m)
54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00 54.00

Over Limit (dB) -18.68 -15.87 -8.71
-19.03 -14.68 -11.32

polarization
Vertical Vertical Vertical Vertical Vertical Horizontal Horizontal Horizontal Horizontal Horizontal

Remark: 1. Result =Reading + Factor
2. Test frequency are from 1GHz to 25GHz, "*" means the test results were attenuated more than 20dB below the permissible limits, so the results don't record in the report.
3. Only the worst case is recorded in the report.

Report No.:1812C40184012501 FCC ID: 2A4KN-PL80E
APPENDIX I -- TEST SETUP PHOTOGRAPH
Please refer to separated files Appendix I -- Test Setup Photograph_RF
APPENDIX II -- EXTERNAL PHOTOGRAPH
Please refer to separated files Appendix II -- External Photograph
APPENDIX III -- INTERNAL PHOTOGRAPH
Please refer to separated files Appendix III -- Internal Photograph

Page 32 of 32

---------------- End of Report ----------------

