Schlage BRIVO ACS300 x GWE, NDE, LE Wiring Diagram

BDove

Schlage BRIVO ACS300 x GWE, NDE, LE Wiring Diagram

PDF preview unavailable. Download the PDF instead.

Schlage BRIVO ACS300 x GWE NDE LE Wiring Diagram 112484
GWE

2x18

UL 294 12/24VDC
POWER SUPPLY

120 VAC

GWE

2x18

UL 294 12/24VDC
POWER SUPPLY

120 VAC

ACS300 TCP/IP

BRIVO

TCP/IP

BRIVO BROWSER

APPLICATION

NDE LOCK

LE LOCK

NDE LOCK

LE LOCK

IP/PoE

GND

+

AC

NEU

-

INPUT LINE UL 294

12/24VDC

SUPPLY

+ -
GND TX+ RX+ TXRX-
+ -
GND TX+ RX+ TXRX-

BELDEN 9842

SHIELD
WHT/ORG ORG/WHT WHT/BLU

IP/PoE

GND

+

AC

NEU

-

INPUT LINE UL 294

12/24VDC

SUPPLY

GND

-

AC

NEU

+

INPUT LINE UL 294

12 VDC

SUPPLY

ACS300 CONTROLLER

RXD + RXD GND TXD + TXD 12 VDC
DATA 0 DATA 1
GND BUZZ 12 VDC GRN LED RED LED

RS-485 DOOR 1 WIEGAND

DATA 0

DATA 1

GND BUZZ

DOOR 2 WIEGAND

12 VDC

GRN LED

RED LED

GND EXTERNAL 12 VDC
12 VDC

LAN/PoE

ADMIN

BRIVO ACS300 CONTROL PANEL WILL SUPPORT UP TO 30 NDE/LE LOCKS ACROSS UP TO 4 GWE ON A SINGLE RS485 PORT. WIRING SHOWN REFLECTS WIRING FROM ACS300 TO GWE ONLY. ADDITIONAL WIRING WILL BE REQUIRED AND IS NOT SHOWN HERE. UL294 POWER SUPPLIES USED SHOULD NOT BOND EARTH GROUND TO SIGNAL GROUND IF PLENUM RATED CABLE IS REQUIRED USE BELDEN 88104 FOR 9844 OR 88102 FOR 3106A OR EQUIVALENT. NOTE: CONFIGURATION HAS NOT BEEN TESTED BY ALLEGION BUT HAS BEEN REVIEWED AND APPROVED BY BRIVO.

TITLE:
BRIVO ACS300 x GWE, NDE, LE

DWG NO:

112484

DRAWN/CHECKED BY:

REV
A

