Schlage BRIVO ACS300 x GWE, NDE, LE Wiring Diagram
BDove
Schlage BRIVO ACS300 x GWE, NDE, LE Wiring Diagram
Schlage BRIVO ACS300 x GWE NDE LE Wiring Diagram 112484 GWE
2x18
UL 294 12/24VDC
POWER SUPPLY
120 VAC
GWE
2x18
UL 294 12/24VDC
POWER SUPPLY
120 VAC
ACS300 TCP/IP
BRIVO
TCP/IP
BRIVO BROWSER
APPLICATION
NDE LOCK
LE LOCK
NDE LOCK
LE LOCK
IP/PoE
GND
+
AC
NEU
-
INPUT LINE UL 294
12/24VDC
SUPPLY
+ -
GND TX+ RX+ TXRX-
+ -
GND TX+ RX+ TXRX-
BELDEN 9842
SHIELD
WHT/ORG ORG/WHT WHT/BLU
IP/PoE
GND
+
AC
NEU
-
INPUT LINE UL 294
12/24VDC
SUPPLY
GND
-
AC
NEU
+
INPUT LINE UL 294
12 VDC
SUPPLY
ACS300 CONTROLLER
RXD + RXD GND TXD + TXD 12 VDC
DATA 0 DATA 1
GND BUZZ 12 VDC GRN LED RED LED
RS-485 DOOR 1 WIEGAND
DATA 0
DATA 1
GND BUZZ
DOOR 2 WIEGAND
12 VDC
GRN LED
RED LED
GND EXTERNAL 12 VDC
12 VDC
LAN/PoE
ADMIN
BRIVO ACS300 CONTROL PANEL WILL SUPPORT UP TO 30 NDE/LE LOCKS ACROSS UP TO 4 GWE ON A SINGLE RS485 PORT. WIRING SHOWN REFLECTS WIRING FROM ACS300 TO GWE ONLY. ADDITIONAL WIRING WILL BE REQUIRED AND IS NOT SHOWN HERE. UL294 POWER SUPPLIES USED SHOULD NOT BOND EARTH GROUND TO SIGNAL GROUND IF PLENUM RATED CABLE IS REQUIRED USE BELDEN 88104 FOR 9844 OR 88102 FOR 3106A OR EQUIVALENT. NOTE: CONFIGURATION HAS NOT BEEN TESTED BY ALLEGION BUT HAS BEEN REVIEWED AND APPROVED BY BRIVO.