User Guide for ENGO Controls models including: E25-230W, E25-230B, E25 ZigBee 868MHz Smart Thermostat, E25 Smart Thermostat, ZigBee 868MHz Smart Thermostat, Smart Thermostat, Thermostat
Binding thermostat with the wireless control box Name the device and click „Done.” The thermostat has been installed and displays the main interface. On the controller screen globe icon appeared stating that
Laidiniai termostatai - Paltaja
Termostatas Engo E25 230B - Paltaja
File Info : application/pdf, 2 Pages, 1.60MB
DocumentDocument25 ZigBee/868MHz Smart Thermostat E25-230W E25-230B Quick Guide Works with Powered By Ver. 2.4 Release date: VII 2024 Soft: ZigBee: v1.0.3 MCU v0.2.4 GET IT ON Available on the Producer: Engo Controls sp z o.o. sp. k. Rolna 4 St. 43-262 Kobielice Poland www.engocontrols.com Product Compliance This product complies with the following EU Directives: 2014/30/EU, 2014/35/EU, 2014/53/ EU, 2011/65/EU SAFETY INFORMATION: Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Please read the entire manual, before installation or use. Installation Installation must be performed by a qualified person with appropriate electrical qualifications, in accordance with the standards and regulations in force in a given country and in the EU. The manufacturer is not responsible for non compliance with the instructions. ATTENTION: For the entire installation, there may be additional protection requirements, which the installer is responsible for. Connection description a) Connection diagram for heating source ZigBee 3.0 b) Connection diagram to pump / actuator ZigBee 3.0 Heating source * NO COM L N max. 3(1)A NO COM L N L AC 230V N c) Connection diagram to the control box ZigBee 3.0 S1 S2 NO COM L N N L SL.. ECB62-ZB ECB8-230 L AC 230V N PE Legend: L, N PE COM, NO Fuse 230V AC power supply Ground (electricity) Voltage-free output SLA, SLB, SL.. Input terminals Pump Valve actuator Wireless communication Heating source* Boiler's contacts for ON/OFF thermostat (according to the boiler's instructions) INTRODUCTION: Internet controlled thermostat with surface-mounted design (230V AC powered). The product is based on a ZigBee/868MHz wireless communication technology. It is designed for radiator or floor heating. It works with electronic wireless heads. It can control up to 6 radiator heads in one room. Thermostat sends temperature measurements to the heads for better control accuracy - it will ensure also comfort and savings. A unique feature of this thermostat is the ability to control devices WIRELESSLY (ENGO binding function). The "ENGO binding" function makes thermostat to communicate directly with receivers, e.g. a wireless control box or relay module (devices with "BIND" function). ZigBee binding can only be performed using the Internet gateway (sold separately). If thermostat is used with an internet gateway connected to the internet, it has the the ability to be controled wirelessly via the ENGO Smart mobile app. When added to the mobile app, thermostat gets additional functions, e.g. time schedules or push notifications. Thermostat has also a key lock function, possibility of setting a minimum and maximum temperature setpoint limits and the ability to operate in heating or cooling mode. Technical data Power supply 230V AC 50 Hz Max. Current 3(1)A Temp.setpointrange 5,0°C to 45,0°C Display temp. Accuracy 0,5°C Control algorithm TPI Hysteresis (±0.1°C to ±2°C) Communication ZigBee 3.0 RF 868MHz Control output NO/COM voltage-free Dimensions [mm] 80 x 80 x 23 LCD Icon Description + Button Description 1 2 34 567 8 10 SET 9 11 12 1 2 3 1. "Down"Button 2. "OK"Button OK 3. "Up"Button + 1. ZigBee network connection indicator 2. Receiver binding indicator 3. Current/Setpoint temperature 4. Heating indicator (icon is animating when there is heating demand) 5. Cooling indicator (icon is animating when there is cooling demand) 6. Schedule mode icon 7. Temporary override mode 8. Frost protection mode 9. Temperature unit 10.Settings icon / temperature settings 11. Settings icon 12. Button lock Button description + + & + & & Change the parameter value up Change the parameter value down Manual/Schedule mode - short button press (Online mode) Enther the installer parameters- hold 3 seconds Turn OFF/ON thermostat - hold 5 seconds Enter the pairing mode - hold 5 seconds Enter Sync / Binding mode - hold 5 seconds Factory reset - hold until the FA message appears Lock/Unlock thermostat keys - hold 3 seconds Heating/Cooling mode change - hold 3seconds Installation thermostat in the app Make sure your router is within range of your smartphone. Make sure you are connected to the Internet. This will reduce the pairing time of the device. STEP 1 - DOWNLOAD ENGO SMART APP Download the ENGO Smart app from Google Play or Apple App Store and install it on your smartphone. Powered By GET IT ON Available on the STEP 2 - REGISTER THE NEW ACCOUNT To register a new account, please follow the steps below: 1 2 3 4 Click ,,Register" to create new account. Enter your e-mail address to which the verification code will be sent. Enter the verification code received in the email. Remember that you only have 60 seconds to enter the code! STEP 3 - CONNECT THE THERMOSTAT TO ZigBee Then set the login password. 1 2 Make sure ZigBee Gateway has been added to the Engo Smart app. Press and hold the and + buttons on the thermostat until the display shows,,PA". Then release the keys. The pairing mode will be started up. 3 4 Thermostat counts the time back (180s). 5 Enter the gateway interface. In,,Zigbee devices list" go,,Add devices". Wait for the message "End" to appear on the thermostat screen. 6 7 8 Name the device and click,,Done". The thermostat has been installed and displays the main interface. On the controller screen globe icon appeared stating that he has been he added to the ZigBee network. Synchronization with head An internet gateway is not mandatory to synchronize thermostat with head. Make sure head is installed and adapted to valve insert (see head manual). If thermostat is connected to a wireless control box or relay module, synchronization with head cannot be activated. 1 2 3s After successful adaptation process, press&hold head button for 3 seconds. The LED will start flashing blue. 3 5 sek. 5 sek. Hold simultaneously and + buttons on thermostat until the "SY" function appears. 4 10 sec. Release buttons, SYNC function will be active (synchronization with head). 5 After successful synchronization, LED diode will indicate blue light for 10 seconds. 6 Binding thermostat with the wireless control box Make sure that the control box and thermostat are in the same ZigBee network (they are added to the same gateway) and the POWER LED lights up blue. 1 5x or or 2 1 2 In order to correctly link thermostat with the control box, first select the zone in the control box with the SELECT button (1) (zone which you want to link with thermostat). The LED (2) will flash 3 times for the selected zone. Confirm your selection by clicking PAIR button (2). The LED (2) will flash green with the previously selected zone - binding process has started, it is active for 10 minutes and during this time you can link thermostat with the selected zone. 5x To properly link thermostat with the module/relay first click quickly the button on the device 5 times. The LED diode will start flashing slowly on red, which means the device is in binding mode. 2 3 4 On the thermostat, hold and + Release the keys, binding function The "binding" process takes up to buttons until the "bind" message process of linking thermostat is 300 seconds. appears. active. 5 6 ATTENTION: If the binding process fails, it must be repeated taking into account the distances between devices, obstacles and local radio signal interferences. Remember: After successfull binding Both devices have been operation ,,End" successfully linked. message will be displayed. Thermostat displays the main screen, icon " " appeared on the screen indicating connection with the receiver. Radio range can be increased by Engo ZigBee repeaters. ATTENTION: When the thermostat is binded with the zone , the zone will turn off after 50 minutes, if the communication between the devices is lost. Installer parameters Pxx Function P01 Heating/CoolingSelection P02 Control algorithm P03 Offset temperature P04 Internal relay Value TPI UFH TPI RAD TPI ELE HIS 0.4 HIS 0.8 HIS 1.2 HIS 1.6 HIS 2.0 HIS 3.0 HIS 4.0 -3.0°C to +3.0°C NO NC OFF Desription Default value Heating Cooling TPI for Underfloor Heating TPI for Radiators TPI for Electrical Heating SPAN +/-0,2°C SPAN +/-0,4°C SPAN +/-0,6°C SPAN +/-0,8°C TPI UFH for heating HIS 0.4 for cooling SPAN+/-1,0°C SPAN +/-1,5°C SPAN+/-2,0°C If the thermostat indicates wrong temperature, you can correct it by max ± 3.0°C" 0°C Relay type NO-COM Relay type NC-COM NO Relay disabled P05 "Minimumsetpoint" 5°C - 45°C Minimumheating/coolingtemperaturethatcanbeset 5°C P06 "Maximumsetpoint" 5°C - 45°C Maximumheating/coolingtemperaturethatcanbeset 35°C P07 Backlightbrightness 10% - 100% Adjustable in the range from 10 to 100% 50% NO P08 PINCodeforsettingsaccess PIN Function disabled NO Function enabled P09 PIN code value 000-xxx user PIN 000 Require a PIN to unlock the keys NO P10 everytime(functionactivewhen P8=PIN) YES Function disabled NO Function enabled ON P11 Valve protection OFF Function enabled OFF Function disabled P12 Latestavailablefirmwareforheads xxx Firmware version available to update heads Read only null - firmware in the heads is latest possible. P13 Currentfirmwareinstalledinheads null - xxx xxx - a newer version is available, press the button - to update the heads In case of room temperature change, head opens P14 Delta RCWC algorithm (only for heads) 0.5°C to 5.0°C proportionally to the size of the delta RCWC parameter. The smaller delta RCWC is, the faster the valve response 2.0 will be. NO CLR Clearsettingsfactoryreset YES No action NO Factory Reset Thermostat will indicate how many heads are synchronized. 7 The devices are synchronized and ready to work. "END" message will appear after successful synchronization. ATTENTION: The synchronization should be performed for each head separately. One thermostat can control up to 6 heads within one room. Installer settings To enter installer parameters press and hold button for 3 seconds. 1 2 SET Factory reset To RESET Thermostat to factory settings, hold down the and + buttons until the FA message appears. Then release the keys. Thermostat will restart, will restore the default factory settings and display the main screen. If the regulator was added to the gate and the ZigBee network, it will be removed from it and you will need to add / pair it again. 1 2 3 3 sec. Use or + button to move between parameters. Enter the parameter by . Edit the parameter using or + Confirm the new parameter value with the button. 10sek. 10 sek.