ALS SLML LED Track Spotlight

The ALS SLML is an LED track spotlight with an aluminum die-cast housing, available in white or black. It is designed for indoor use in dry, closed rooms and operates on power-track systems (Global, Eutrac, Erco, Nokia). These luminaires contain a light source of energy efficiency class F.

Technical Data

Protection Class: II | Protection Class: IP20 | CRI>90 | Not dimmable

Beam angle: SLML-12 = 20°, SLML-16 = 40°

Connected Load 12W (220-250V, 50 Hz)

Art.-No. CCT Light Source Eprel-No.
SLML-12NW 4000K Bridgelux COB - BXRE-40G1000-A-82 870308
SLML-12WNW 3500K Bridgelux COB - BXRE-35G1000-A-82 869992
SLML-12WW 3000K Bridgelux COB - BXRE-30G1000-A-82 869641
SLML-12SW 2700K Bridgelux COB - BXRE-27G1000-A-82 869213

Connected Load 16W (220-250V, 50 Hz)

Art.-No. CCT Light Source Eprel-No.
SLML-16NW 4000K Bridgelux COB - BXRE-40G1000-A-82 870308
SLML-16WNW 3500K Bridgelux COB - BXRE-35G1000-A-82 869992
SLML-16WW 3000K Bridgelux COB - BXRE-30G1000-A-82 869641
SLML-16SW 2700K Bridgelux COB - BXRE-27G1000-A-82 869213

Dimensions

Luminaire height: 164 mm

Luminaire head: Ø64 x H130 mm

The product consists of two components: the luminaire with light source and the internal power supply. The light source and the LED driver are only exchangeable by a professional.

Safety and Operation

⚠️ READ THE INSTRUCTIONS BEFORE USING THIS PRODUCT. KEEP THE SAFETY AND OPERATING INSTRUCTIONS FOR FUTURE USE.

Warranty claims and guarantees are void if damage occurs due to failure to follow operating instructions. ALS GmbH is not liable for consequential damage. Special terms for planning and installing LED products apply.

Safety Information

Maintenance, Cleaning, and Disposal

Maintenance and Cleaning

Disposal

Intended Usage

This product will only serve the purpose of illumination.

Scope of Delivery

Technical Changes

Changes for technical progress may be made without prior notice.

Installation Guide

  1. Step 01: Switch off power before installation. Switch on only after complete installation and circuit examination. Installation and maintenance must be performed by a professional electrician. Turn off power supply before starting any installation. Read instructions and ensure all necessary tools and accessories are available.
  2. Step 02: Check the adapter before inserting. Ensure all plastic locks and contacts are flush within the adapter. All interlocks and switching positions must be in the zero position. Failure to do so will destroy the adapter and render it unusable.
  3. Step 03: Attention! The adapter can only be installed in a 3-phase track in one direction. The locking mechanism must be placed on the track side as marked with 'A'. Place the luminaire in the correct position with the track adapter. Lock the retaining latch.
  4. Step 04: Set the phase using the side phase selection dial for commissioning the luminaire with the contact selection switch (1/2/3). Any installation, assembly, materials, or types different from those provided in the manual sheets release ALS GmbH from any electrotechnical and electrostatic responsibility.
  5. Step 05: After installation and connection, switch on the mains voltage all-pole. Switch on the associated circuit breaker or turn the fuse on.
  6. Step 06: ⚠️ Avoid looking too long into the light exit near the light, as it could damage your eyes.
  7. Step 07 (Removal): Disconnect the mains voltage from all poles before disassembly. When removing, first set the phase wheel to zero. Release the lock and hold the spotlight with one hand.

Contact Information

A.L.S. GmbH

Mastorter Str. 31 | 88069 Tettnang (Germany)

Tel.: +49 (0) 75 42 93 44-0 | Fax.: +49 (0) 75 42 93 44-30

E-Mail: info@als.de | Web: www.als.de

Version: 2024-08-01

Models: SLML-12NW, SLML-12WNW, SLML-12WW, SLML-12SW, SLML-16NW, SLML-16WNW, SLML-16WW, SLML-16SW, SLML-16SW LED Track Spotlight, SLML-16SW, LED Track Spotlight, Track Spotlight, Spotlight