ALS SLML LED Track Spotlight
The ALS SLML is an LED track spotlight with an aluminum die-cast housing, available in white or black. It is designed for indoor use in dry, closed rooms and operates on power-track systems (Global, Eutrac, Erco, Nokia). These luminaires contain a light source of energy efficiency class F.
Technical Data
Protection Class: II | Protection Class: IP20 | CRI>90 | Not dimmable
Beam angle: SLML-12 = 20°, SLML-16 = 40°
Connected Load 12W (220-250V, 50 Hz)
| Art.-No. | CCT | Light Source | Eprel-No. |
|---|---|---|---|
| SLML-12NW | 4000K | Bridgelux COB - BXRE-40G1000-A-82 | 870308 |
| SLML-12WNW | 3500K | Bridgelux COB - BXRE-35G1000-A-82 | 869992 |
| SLML-12WW | 3000K | Bridgelux COB - BXRE-30G1000-A-82 | 869641 |
| SLML-12SW | 2700K | Bridgelux COB - BXRE-27G1000-A-82 | 869213 |
Connected Load 16W (220-250V, 50 Hz)
| Art.-No. | CCT | Light Source | Eprel-No. |
|---|---|---|---|
| SLML-16NW | 4000K | Bridgelux COB - BXRE-40G1000-A-82 | 870308 |
| SLML-16WNW | 3500K | Bridgelux COB - BXRE-35G1000-A-82 | 869992 |
| SLML-16WW | 3000K | Bridgelux COB - BXRE-30G1000-A-82 | 869641 |
| SLML-16SW | 2700K | Bridgelux COB - BXRE-27G1000-A-82 | 869213 |
Dimensions
Luminaire height: 164 mm
Luminaire head: Ø64 x H130 mm
The product consists of two components: the luminaire with light source and the internal power supply. The light source and the LED driver are only exchangeable by a professional.
Safety and Operation
⚠️ READ THE INSTRUCTIONS BEFORE USING THIS PRODUCT. KEEP THE SAFETY AND OPERATING INSTRUCTIONS FOR FUTURE USE.
Warranty claims and guarantees are void if damage occurs due to failure to follow operating instructions. ALS GmbH is not liable for consequential damage. Special terms for planning and installing LED products apply.
Safety Information
- The luminaire is suitable for indoor use only, in dry and closed rooms.
- [Power Off Symbol] Do not install under power.
- Follow the instruction manual for installation.
- Installation only by qualified and authorized persons.
- Do not use the product if damaged (defective covers) or if operational faults occur (flickering, smoking, steaming, crackling noises, or smell of smoke).
- A damaged or defective product must be changed or repaired by the manufacturer, a service person, or a comparable qualified person.
- Installation must comply with valid guidelines specific to the application and country, including VDE 0.100.
- Never open electrical operating components or insert objects into them, as this poses a risk of electric shock.
- Absolutely avoid contact between the product and water or other liquids. For electrical safety reasons, the light must not come into contact with or be submerged in water.
- The product may not be changed or modified.
- ⚠️ During operation or after extended periods, avoid touching the external surface of the LED luminaire due to the danger of high temperatures that can cause burns.
- ⚠️ Do not look directly into the LED! The LED is bright enough to potentially damage your eyes.
- The luminaire must not be exposed to high levels of dust.
Maintenance, Cleaning, and Disposal
Maintenance and Cleaning
- The light source is only exchangeable by a professional.
- Do not use solvents, such as benzene or similar agents, as they can damage the light.
- Only use a dry, lint-free cloth for cleaning the product.
Disposal
- The packaging consists of environmentally friendly materials. Dispose of them in local recycling containers.
- Do not dispose of this product in household garbage at the end of its lifecycle. Take it to a designated disposal center. Local officials can provide information about collection offices and their hours.
Intended Usage
This product will only serve the purpose of illumination.
Scope of Delivery
- LED track spotlight with adapter
- Set of instructions for assembly, operation, and safety
Technical Changes
Changes for technical progress may be made without prior notice.
Installation Guide
- Step 01: Switch off power before installation. Switch on only after complete installation and circuit examination. Installation and maintenance must be performed by a professional electrician. Turn off power supply before starting any installation. Read instructions and ensure all necessary tools and accessories are available.
- Step 02: Check the adapter before inserting. Ensure all plastic locks and contacts are flush within the adapter. All interlocks and switching positions must be in the zero position. Failure to do so will destroy the adapter and render it unusable.
- Step 03: Attention! The adapter can only be installed in a 3-phase track in one direction. The locking mechanism must be placed on the track side as marked with 'A'. Place the luminaire in the correct position with the track adapter. Lock the retaining latch.
- Step 04: Set the phase using the side phase selection dial for commissioning the luminaire with the contact selection switch (1/2/3). Any installation, assembly, materials, or types different from those provided in the manual sheets release ALS GmbH from any electrotechnical and electrostatic responsibility.
- Step 05: After installation and connection, switch on the mains voltage all-pole. Switch on the associated circuit breaker or turn the fuse on.
- Step 06: ⚠️ Avoid looking too long into the light exit near the light, as it could damage your eyes.
- Step 07 (Removal): Disconnect the mains voltage from all poles before disassembly. When removing, first set the phase wheel to zero. Release the lock and hold the spotlight with one hand.
Contact Information
A.L.S. GmbH
Mastorter Str. 31 | 88069 Tettnang (Germany)
Tel.: +49 (0) 75 42 93 44-0 | Fax.: +49 (0) 75 42 93 44-30
E-Mail: info@als.de | Web: www.als.de
Version: 2024-08-01