FCC3450 3000A Flexible Clamp Meter User Guide This document is copyright of: Megger Limited, Archcliffe Road, Dover, Kent CT17 9EN. ENGLAND T +44 (0)1304 502101 F +44 (0)1304 207342 www.megger.com Megger Ltd reserves the right to alter the specification of its products from time to time without notice. Although every effort is made to ensure the accuracy of the information contained within this document it is not warranted or represented by Megger Ltd. to be a complete and up - to - date description. For Patent information about this instrument refer to the following web site: megger.com/patents 2 FCC3450 www.megger.com This manual supersedes all previous issues of this manual. Please ensure that you are using the most recent issue of this document. Destroy any copies that are of an older issue. Declaration of Conformity Hereby, Megger Instruments Limited declares that radio equipment manufactured by Megger Instruments Limited described in this user guide is in compliance with Directive 2014/53/EU. Other equipment manufactured by Megger Instruments Limited described in this user guide is in compliance with Directives 2014/30/EU and 2014/35/EU where they apply. The full text of Megger Instruments EU declarations of conformity are available at the following internet address: megger.com/company/about-us/eu-dofc www.megger.com FCC3450 3 Introduction 1. Introduction This instruction manual contains information regarding the correct use and handling of the FCC3450. Please ensure to consult the chapter `Safety warnings and standards'. This chapter contains information regarding your personal safety when using the product. 1.1 Product description The Megger FCC3450 is a Bluetooth� enabled flexible current clamp, designed to make AC/DC voltage, frequency, continuity and resistance measurements, as well as AC current up to 3000 A. 1.2 Features Up to 3000 A AC current measurement 1000 V AC/DC measurement 150 mm maximum conductor size Megger LinkTM app compatible Continuity and frequency measurement Data hold on all ranges Low battery LED indicator CAT IV 600 V/CAT III 1000 V supplied with protective carry pouch 1.3 Applications The FCC3450 is a CAT IV/600 V rated flexible current clamp, measuring up to 1000 V AC/DC and up to 3000 A AC. Due to the length and flexibility of the coil, measurements can be made around large conductors, or those conductors inaccessible to a fixed-head clamp. Pairing with the free Megger LinkTM app give the user the ability to make remote rreadings or record measurements directly to their smart device for storage or report creation. 1.4 Company web site Occasionally an information bulletin may be issued via the Megger web site. This may concern new accessories, new usage or user instructions or a software update. Please occasionally check on the Megger web site for anything applicable to your Megger instruments. www.megger.com 4 FCC3450 www.megger.com Safety Warnings and Standards 2. Safety Warnings and Standards These safety warnings must be read and understood before the instrument is used. Please retain for future reference. To ensure safe operation and service of the FCC3450, follow these instructions. Failure to observe warnings can result in severe INJURY or DEATH. 2.1 Warnings, Cautions and Notes This user guide follows the internationally recognised definition. These instructions must be adhered to at all times. Description WARNING : Indicates a potentially dangerous situation which, if ignored, could lead to death, serious injury or health problems. ATTENTION : Indicates a dangerous situation which, if ignored, could lead to injuries or health problems. CAUTION : Indicates a situation which could lead to damage of the equipment or environment NOTE : Indicates important instructions to be followed to perform the relevant process safely and efficiently. 2.2 Safety warnings If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. To reduce the risk of fire or electric shock, do not use this product around explosive gas or in damp locations. Verify the Meter operation by measuring a known resistance, voltage and current. If in doubt, have the Meter serviced. Do not apply more than the rated voltage - as marked on the Meter - between the terminals or between any terminal and earth. To avoid inaccurate of false readings that may lead to an electric shock or injury, replace the battery as soon as the 10% battery life is shown, or the low battery symbol appears. Avoid working alone. Do not use the FCC3450 if it is not operating correctly or if it is wet. When using the FCC3450, the test leads or the probes/crocodile clips, always keep you fingers behind the finger/hand guards. Use caution with voltages above 30 Vac rms, 42 Vac peak, or 60 Vdc. These voltages pose a shock hazard. Remove the flexible coil from any conductor and the leads from both terminals before opening the battery door to replace batteries. www.megger.com FCC3450 5 Safety Warnings and Standards DO NOT USE the test leads if they appear damaged or the internal white insulation layer is exposed. DO NOT USE the test leads, probes or crocodile clips in any environment above their maximum category rating. DO NOT USE the test leads without the probe tip guard cap in CAT III and CAT IV environments. Probe assemblies to be used for MAINS measurements shall be RATED as appropriate for MEASUREMENT CATEGORY III or IV according to IEC 61010-031 and shall have a voltage RATING of at least the voltage of the circuit to be measured. Disconnect the circuit power and discharge all high voltage capacitors before testing resistance or continuity. DO NOT USE the flexible current sensor if the insulation appears damaged or the inner copper wire is visible. De-energize the installation under test when fitting and removing the Flexible Current Probe. Do not apply around or remove from UNINSULATED HAZARDOUS LIVE conductors. Do not open the instrument case, there are no user serviceable parts inside. In the event of a fault, return the FCC3450 to Megger or an Approved Service Centre. CAUTION : Identify conditions and actions that could damage the FCC3450, the equipment under test, or cause permanent loss of data. Remove the batteries if the FCC3450 will not be used for an extended period of time, or if storing in temperatures above 50 �C. If the batteries are not removed, battery leakage may damage the FCC3450. Do not expose the FCC3450 to extremes of temperature or high humidity. NOTE : The instrument must only be used by suitable trained and competent persons Installation category definitions: CAT IV - Measurement category IV: Equipment connected between the origin of the lowvoltage mains supply and distribution panel. CAT III -Measurement category III: Equipment connected between the distribution panel and electrical outlets. CAT II - Measurement category II: Equipment connected between the electrical outlets and user's equipment. Measurement equipment may be safely connected to circuits at the marked rating or lower. The connection rating is that of the lowest rated component in the measurement circuit. 6 FCC3450 www.megger.com Safety Warnings and Standards 2.3 Safety, Hazard and Warning symbols on the instrument This table details the various safety and hazard icons on the instrument's outer case. Icon F Description Warning: High Voltage, risk of electric shock G Caution: Refer to user guide. Do not apply or remove the clamp from HAZARDOUS LIVE conductors AC (Alternating Current or Voltage) DC (Direct Current or Voltage) Both AC and DC CAT IV CAT III g t IEC Overvoltage Category CAT III equipment is designed to protect against transients in equipment in fixed equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. CAT IV equipment is designed to protect against transients from the primary supply level, such as an electricity Meter or an overhead or underground utility service. Reference earth connection. Not a protective earth terminal Equipment protected throughout by double insulation. Battery capacity Bluetooth UK conformity. This equipment complies with current UK directives c EU conformity. Equipment complies with current EU directives. Do not dispose of in the normal waste stream. www.megger.com FCC3450 7 Instrument Overview 3. Instrument Overview 3.1 Instrument layout 6 1 2 3 Item 1 2 3 54 Description Clamp lock mechanism LCD display Function buttons Item 4 5 6 Description V- input terminal COM input terminal Work light 8 FCC3450 www.megger.com 3.2 Instrument display 6 1 Instrument Overview 5 2 Item 1 2 3 3 Description Meter status symbols Battery capacity symbol Primary measurement 4 Item 4 5 6 Description Function unit symbols Hold symbol Secondary measurement www.megger.com FCC3450 9 Operation 4. Operation 4.1 Power On / Off Press > 2 sec Off Press and hold the on/off button for longer than 2 seconds. When turning on, the display indicates the current battery capacity. The battery must be replaced if 10% or less is shown to avoid false or inaccurate readings. 4.2 Auto Power Off (APO) 20 mins Auto power Off is turned on by default and APO is shown on the display. If there is no user input, the FCC3450 will auto power off after 20 minutes. 10 FCC3450 www.megger.com 4.3 Disable Auto Power Off Operation Press > 2 sec Off To disable Auto Power Off, push and hold the Bluetooth button when turning the FCC3450 on. When AoFF appears on the LCD, release both buttons. The APO symbol on the display should not be visible. 4.4 Input Selection The FCC3450 prioritises any terminal input measurement over the flexible coil current measurement. The meter will default to show a voltage, resistance or continuity measurement if connected to the input terminals when making a current measurement. Removing any terminal input will cause the FCC3450 to return to displaying the measured current value, if present. www.megger.com FCC3450 11 Operation 4.4.1 AC Current Measurement WARNING : The barrier on the JAW (indicated below) defines the limit of safe access of the hand held part of the meter. Do not place hands past the barrier when in normal use. Barrier for hand guard 12 FCC3450 www.megger.com 4.4.2 Unlock / Lock Flexible Coil Operation Turn counter-clockwise to unlock the flexible coil Turn clockwise to lock the flexible coil Turn the clamp lock counter-clockwise to release the flexible clamp. Place the flexible clamp around a single conductor only. Insert the flexible clamp back in the clamp lock and turn clockwise to secure. Check that the flexible clamp is secure before making any measurement. www.megger.com FCC3450 13 Operation 4.4.3 Position Error For maximum accuracy, the single conductor should be positioned in the center of the flexible clamp where possible. See detailed specification for position accuracy error. 14 FCC3450 www.megger.com Operation 4.5 Voltage, Resistance and Continuity WARNING : When connecting the test leads, always connect the common test lead before connecting the live test lead. When removing the test leads, remove the live test lead before removing the common test lead. WARNING : Do not use the FCC3450 to measure voltages in circuits that could be damaged by the meters LoZ mode low impedance (approx. 4 k). NOTE : During a continuity measurement, the built-in buzzer sounds when measured resistance is less than 20 and turns off when measured resistance is greater than 200 . Between 20 to 200 the buzzer may still sound. www.megger.com FCC3450 15 Operation 4.6 Data Hold Press Data Hold can be used to retain the diaplayed values on any range. To turn on Data Hold, briefly press the Data Hold button. To return to normal measurement mode, press the Data Hold button a second time. H is shown in the display when Data Hold is active. 4.7 Bluetooth� Mobile device The FCC3450 uses low-power Bluetooth� v4.0 wireless technology to transfer real-time data. To use the communication link on Android or iOS devices, install the Megger LinkTM App. 16 FCC3450 www.megger.com Operation Megger LinkTM on Megger LinkTM on Apple App Store Google Play Download the "Megger LinkTM" App. Turn on the Bluetooth function of the meter by pressing the Bluetooth button and open the Megger LinkTM App to connect the DCM. The Bluetooth icon of the meter will flash whilst connecting and freeze on the LCD after the connection is established. Max. communication range: Open air up to 10 m 4.8 Backlight Press the yellow backlight button once to turn the display backlight on or off. 4.9 Work light Press and hold the yellow backlight button for >1sec to turn the work light on or off. 4.10 Battery Replacement Remove the FCC3450 from any measurement circuit and remove all test leads before opening battery cover. Unscrew Batteries MUST be replaced as soon as 10% battery capacity is reached. www.megger.com FCC3450 17 Specifications 5. Specifications 5.1 General Specifications LCD display digits: 9,999 digit large scale LCD readout Overload display: OL or -OL Battery Type: 2 Batteries, IEC LR6, NEDA 15 A, Alkaline (AA) Battery Life: Typically 60 hours (Alkaline) Auto Power Off: The Meter automatically turns off after 20 minutes if no buttons are pressed. Max. Conductor Size: approx. 150 mm / 6.0" Dimensions (H x W x D): 196 mm (excluding coil) x 112 mm x 35 mm Weight (without batteries): 256 g 5.2 Environmental Conditions Temperature Coefficient: 0.1 x (specified accuracy) / �C (<18�C or >28�C) Operating Temperature: -10�C to 30�C ( 80% R.H.) 30�C to 40�C ( 75% R.H.) 40�C to 50�C ( 45% R.H.) Storage Temperature: -20�C to 60�C ( 80% R.H., no batteries) Max. Operating Altitude: 2000m (6562 ft.) Drop Protection: 1.2 m drop to hardwood on concrete floor Vibration: Random Vibration per MIL-PRF-28800F Class 2 Recommended calibration period: 12 Months Indoor Use Only 5.2.1 Safety Standards: IEC / EN 61010-1 EN 61010-2-032 EN 61010-2-033 CATIV 600 V, CATIII 1000 V Pollution Degree 2 18 FCC3450 www.megger.com 5.2.2 Electromagnetic Compatibility Standards (EMC): EN 61326-1 Specifications 5.2.3 Wireless Communications Bluetooth� Low Energy (4.0) Radio Frequency: 2.4 GHz ISM Band Effective range: Open air 10 m 5.3 Electrical Specifications Accuracy is given as � (% of reading + counts of least significant digit) at 23�C � 5�C ( 80% R.H.) 5.3.1 AC Function ACV and ACA specifications are AC coupled, True RMS. For non-sinusoidal waveforms, adjust accuracy by Crest Factor (C.F.): Add 1.0% for C.F. 1.0 to 2.0 Add 2.5% for C.F. 2.0 to 2.5 Add 4.0% for C.F. 2.5 to 3.0 5.3.2 Max. Crest Factor of Input Signal: Range 30 A 300 A 3000 A Max. Crest Factor 3.0 2.0 1.5 Limit 1500 counts 2250 counts 3000 counts 1000 V 3.0 5000 counts 2.0 7500 counts 1.5 9999 counts Frequency Response is specified for a sinewave waveform. www.megger.com FCC3450 19 Specifications 5.3.3 AC Ampere Range 30 A* 300 A 3000 A Resolution 0.01 A 0.1 A 1 A * Minimum Reading is 1.00 A Frequency Response : 45 Hz to 500 Hz Overload Protection : 3000 A Accuracy �(3.0%+5D) �(3.0%+5D) �(3.0%+5D) 5.3.4 Position Error of Clamp Model FCC3450 Distance from optimum 35 mm/1.4" 50 mm/2.0" 60 mm/2.4" Accuracy �1.0% �1.5% �2.0% 5.3.5 Voltage Function AC DC Range 1000 V* 1000 V** Resolution 0.1 V 0.1 V Accuracy �(1.5%+5D) �(0.7%+5D) * Minimum Reading is 3.0 V ** Minimum Reading is +2.4 V / -0.7 V AC Frequency Response: 45 Hz to 500 Hz Input Impedance: >4 k for input voltage up to 30 V, impedance increases to >375 k with an input voltage up to 1000 V. Maximum Operation Time : DT = 30 sec for > 30 V Overload Protection: AC / DC 1000 V 20 FCC3450 www.megger.com 5.3.6 AC Frequency Specifications Range 100 Hz* 1000 Hz 10 kHz Resolution 0.1 Hz 1 Hz 0.01 kHz Accuracy �(0.3%+3D) �(0.3%+3D) �(0.3%+3D) * Minimum Reading is 10 Hz 5.3.7 Minimum Sensitivity : AC A: Reading > 3 A at 40 Hz to 1 kHz, > 6 A at < 40 Hz or > 1 kHz AC V: Reading > 10 V at 40 Hz to 1 kHz, > 20 V at < 40 Hz or > 1 kHz 5.3.8 Resistance / Continuity Range 1000 10 k Resolution 1 0.001 k Accuracy �(0.9%+2D) �(0.9%+2D) Continuity Indicator : Built-in buzzer sounds when measured resistance is less than 20 and turns off when measured resistance is greater than 200 . Between 20 to 200 the buzzer may still sound. Response Time of Buzzer: < 1 ms Maximum Output Voltage: 2.1 V Overload Protection: AC / DC 1000 V 5.3.9 Measuring Rate and Response Time Function V / A Hz Measuring Rate 2 sample(s) per sec 1 sample(s) per sec 3 sample(s) per sec Response Time 2 sec 2 sec 2 sec www.megger.com FCC3450 21 Maintenance. 6. Maintenance. 6.1 Maintenance Do not attempt to repair this clamp meter. It contains no user-serviceable parts. Repair or servicing should only be performed by qualified personnel. To maintain the best accuracy, calibrate the FCC3450 once per year. 6.2 Cleaning Periodically wipe the case with a damp cloth and mild detergent, do not use abrasives or solvents. Ensure the case is completely dry before use. 6.3 Storage Remove the batteries if the FCC3450 is not used for an extended period of time or if storing in temperatures above 50�C. If the batteries are not removed, they may leak and damage the FCC3450. 22 FCC3450 www.megger.com 7. Decommissioning Decommissioning 7.1 WEEE Directive The crossed out wheeled bin symbol placed on Megger products is a reminder not to dispose of the product at the end of its life with general waste. Megger is registered in the UK as a Producer of Electrical and Electronic Equipment. The Registration No is WEE/ HE0146QT. For further information about disposal of the product consult your local Megger company or distributor or visit your local Megger website. 7.2 Battery disposal The crossed out wheeled bin symbol placed on a battery is a reminder not to dispose of batteries with general waste when they reach the end of their usable life. For disposal of batteries in other parts of the EU contact your local Megger branch or distributor. Megger is registered in the UK as a producer of batteries (registration No.: BPRN00142). For further information see www.megger.com 7.3 Warranty (3 years) This Meter is warranted to the original purchaser against defects in material and workmanship for 3 years from the date of purchase. During this warranty period, the manufacturer will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. The manufacturer shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you. www.megger.com FCC3450 23 Local Sales office Megger Limited Archcliffe Road Dover Kent CT17 9EN ENGLAND T. +44 (0)1 304 502101 F. +44 (0)1 304 207342 Manufacturing sites Megger Limited Archcliffe Road Dover Kent CT17 9EN ENGLAND T. +44 (0)1 304 502101 F. +44 (0)1 304 207342 Megger USA - Dallas 4545 West Davis Street Dallas TX 75237 USA T. 800 723 2861 (USA only) T. +1 214 333 3201 F. +1 214 331 7399 E. USsales@megger.com Megger GmbH Weststra�e 59 52074 Aachen T. +49 (0) 241 91380 500 E. info@megger.de Megger AB Rinkebyv�gen 19, Box 724, SE-182 17 DANDERYD T. +46 08 510 195 00 E. seinfo@megger.com Megger USA - Valley Forge Valley Forge Corporate Center 2621 Van Buren Avenue Norristown Pennsylvania, 19403 USA T. +1 610 676 8500 F. +1 610 676 8610 Megger USA - Fort Collins 4812 McMurry Avenue Suite 100 Fort Collins CO 80525 USA T. +1 970 282 1200 This instrument is manufactured in the Taiwan. The company reserves the right to change the specification or design without prior notice. Megger is a registered trademark The Bluetooth� word mark and logos are registered trademarks owned by Bluetooth SIG, Inc and is used under licence. FCC3450_UG_en_V01 02 2022 � Megger Limited 2020 www.megger.com